137 lines
4.1 KiB
Text
137 lines
4.1 KiB
Text
.\" Man page generated from reStructuredText.
|
|
.
|
|
.
|
|
.nr rst2man-indent-level 0
|
|
.
|
|
.de1 rstReportMargin
|
|
\\$1 \\n[an-margin]
|
|
level \\n[rst2man-indent-level]
|
|
level margin: \\n[rst2man-indent\\n[rst2man-indent-level]]
|
|
-
|
|
\\n[rst2man-indent0]
|
|
\\n[rst2man-indent1]
|
|
\\n[rst2man-indent2]
|
|
..
|
|
.de1 INDENT
|
|
.\" .rstReportMargin pre:
|
|
. RS \\$1
|
|
. nr rst2man-indent\\n[rst2man-indent-level] \\n[an-margin]
|
|
. nr rst2man-indent-level +1
|
|
.\" .rstReportMargin post:
|
|
..
|
|
.de UNINDENT
|
|
. RE
|
|
.\" indent \\n[an-margin]
|
|
.\" old: \\n[rst2man-indent\\n[rst2man-indent-level]]
|
|
.nr rst2man-indent-level -1
|
|
.\" new: \\n[rst2man-indent\\n[rst2man-indent-level]]
|
|
.in \\n[rst2man-indent\\n[rst2man-indent-level]]u
|
|
..
|
|
.TH "NAMED-CHECKCONF" "1" "@RELEASE_DATE@" "@PACKAGE_VERSION@" "BIND 9"
|
|
.SH NAME
|
|
named-checkconf \- named configuration file syntax checking tool
|
|
.SH SYNOPSIS
|
|
.sp
|
|
\fBnamed\-checkconf\fP [\fB\-achjlvz\fP] [\fB\-p\fP [\fB\-x\fP ]] [\fB\-t\fP directory] {filename}
|
|
.SH DESCRIPTION
|
|
.sp
|
|
\fBnamed\-checkconf\fP checks the syntax, but not the semantics, of a
|
|
\fI\%named\fP configuration file. The file, along with all files included by it, is parsed and checked for syntax
|
|
errors. If no file is specified,
|
|
\fB@sysconfdir@/named.conf\fP is read by default.
|
|
.sp
|
|
Note: files that \fI\%named\fP reads in separate parser contexts, such as
|
|
\fBrndc.conf\fP or \fBrndc.key\fP, are not automatically read by
|
|
\fBnamed\-checkconf\fP\&. Configuration errors in these files may cause
|
|
\fI\%named\fP to fail to run, even if \fBnamed\-checkconf\fP was
|
|
successful. However, \fBnamed\-checkconf\fP can be run on these files
|
|
explicitly.
|
|
.SH OPTIONS
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-a
|
|
Don\(aqt check the \fIdnssec\-policy\fP\(aqs DNSSEC key algorithms against
|
|
those supported by the crypto provider. This is useful when checking
|
|
a \fInamed.conf\fP intended to be run on another machine with possibly a
|
|
different set of supported DNSSEC key algorithms.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-h
|
|
This option prints the usage summary and exits.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-j
|
|
When loading a zonefile, this option instructs \fI\%named\fP to read the journal if it exists.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-l
|
|
This option lists all the configured zones. Each line of output contains the zone
|
|
name, class (e.g. IN), view, and type (e.g. primary or secondary).
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-c
|
|
This option specifies that only the \(dqcore\(dq configuration should be checked. This suppresses the loading of
|
|
plugin modules, and causes all parameters to \fBplugin\fP statements to
|
|
be ignored.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-i
|
|
This option ignores warnings on deprecated options.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-p
|
|
This option prints out the \fI\%named.conf\fP and included files in canonical form if
|
|
no errors were detected. See also the \fI\%\-x\fP option.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-t directory
|
|
This option instructs \fI\%named\fP to chroot to \fBdirectory\fP, so that \fBinclude\fP directives in the
|
|
configuration file are processed as if run by a similarly chrooted
|
|
\fI\%named\fP\&.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-v
|
|
This option prints the version of the \fBnamed\-checkconf\fP program and exits.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-x
|
|
When printing the configuration files in canonical form, this option obscures
|
|
shared secrets by replacing them with strings of question marks
|
|
(\fB?\fP). This allows the contents of \fI\%named.conf\fP and related files
|
|
to be shared \- for example, when submitting bug reports \-
|
|
without compromising private data. This option cannot be used without
|
|
\fI\%\-p\fP\&.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-z
|
|
This option performs a test load of all zones of type \fBprimary\fP found in \fI\%named.conf\fP\&.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B filename
|
|
This indicates the name of the configuration file to be checked. If not specified,
|
|
it defaults to \fB@sysconfdir@/named.conf\fP\&.
|
|
.UNINDENT
|
|
.SH RETURN VALUES
|
|
.sp
|
|
\fBnamed\-checkconf\fP returns an exit status of 1 if errors were detected
|
|
and 0 otherwise.
|
|
.SH SEE ALSO
|
|
.sp
|
|
\fI\%named(8)\fP, \fI\%named\-checkzone(8)\fP, BIND 9 Administrator Reference Manual.
|
|