PR_Wait
|
|
=======
|
|
|
|
Waits for an application-defined state of the monitored data to exist.
|
|
|
|
|
|
Syntax
|
|
------
|
|
|
|
.. code::
|
|
|
|
#include <prmon.h>
|
|
|
|
PRStatus PR_Wait(
|
|
PRMonitor *mon,
|
|
PRIntervalTime ticks);
|
|
|
|
|
|
Parameters
|
|
~~~~~~~~~~
|
|
|
|
The function has the following parameter:
|
|
|
|
``mon``
|
|
A reference to an existing structure of type :ref:`PRMonitor`. The
|
|
monitor object referenced must be one for which the calling thread
|
|
currently holds the lock.
|
|
``ticks``
|
|
The amount of time (in :ref:`PRIntervalTime` units) that the thread is
|
|
willing to wait for an explicit notification before being
|
|
rescheduled.
|
|
|
|
|
|
Returns
|
|
~~~~~~~
|
|
|
|
The function returns one of the following values:
|
|
|
|
- :ref:`PR_SUCCESS`` means the thread is being resumed from the ``PR_Wait`
|
|
call either because it was explicitly notified or because the time
|
|
specified by the parameter ``ticks`` has expired.
|
|
- :ref:`PR_FAILURE` means ``PR_Wait`` encountered a system error (such as
|
|
an invalid monitor reference) or the thread was interrupted by
|
|
another thread.
|
|
|
|
|
|
Description
|
|
-----------
|
|
|
|
A call to :ref:`PR_Wait` causes the thread to release the monitor's lock,
|
|
just as if it had called :ref:`PR_ExitMonitor` as many times as it had
|
|
called :ref:`PR_EnterMonitor`. This has the effect of making the monitor
|
|
available to other threads. When the wait is over, the thread regains
|
|
control of the monitor's lock with the same entry count it had before
|
|
the wait began.
|
|
|
|
A thread waiting on the monitor resumes when the monitor is notified or
|
|
when the timeout specified by the ``ticks`` parameter elapses. The
|
|
resumption from the wait is merely a hint that a change of state has
|
|
occurred. It is the responsibility of the programmer to evaluate the
|
|
data and act accordingly. This is usually done by evaluating a Boolean
|
|
expression involving the monitored data. While the Boolean expression is
|
|
false, the thread should wait. The thread should act on the data only
|
|
when the expression is true. The boolean expression must be evaluated
|
|
while in the monitor and within a loop.
|
|
|
|
In pseudo-code, the sequence is as follows:
|
|
|
|
| ``PR_EnterMonitor(&ml);``
|
|
| ``while (!expression) wait;``
|
|
| ``... act on the state change ...``
|
|
| ``PR_ExitMonitor(&ml);``
|
|
|
|
A thread can be resumed from a wait for a variety of reasons. The most
|
|
obvious is that it was notified by another thread. If the value of
|
|
timeout is not ``PR_INTERVAL_NO_TIMEOUT``, :ref:`PR_Wait` resumes execution
|
|
after the specified interval has expired. If a timeout value is used,
|
|
the Boolean expression must include elapsed time as part of the
|
|
monitored data.
|
|
|
|
Resuming from the wait is merely an opportunity to evaluate the
|
|
expression, not an assertion that the expression is true.
|