diff options
author | Daniel Baumann <daniel.baumann@progress-linux.org> | 2024-05-06 01:02:30 +0000 |
---|---|---|
committer | Daniel Baumann <daniel.baumann@progress-linux.org> | 2024-05-06 01:02:30 +0000 |
commit | 76cb841cb886eef6b3bee341a2266c76578724ad (patch) | |
tree | f5892e5ba6cc11949952a6ce4ecbe6d516d6ce58 /Documentation/input/devices/cma3000_d0x.rst | |
parent | Initial commit. (diff) | |
download | linux-76cb841cb886eef6b3bee341a2266c76578724ad.tar.xz linux-76cb841cb886eef6b3bee341a2266c76578724ad.zip |
Adding upstream version 4.19.249.upstream/4.19.249
Signed-off-by: Daniel Baumann <daniel.baumann@progress-linux.org>
Diffstat (limited to 'Documentation/input/devices/cma3000_d0x.rst')
-rw-r--r-- | Documentation/input/devices/cma3000_d0x.rst | 139 |
1 files changed, 139 insertions, 0 deletions
diff --git a/Documentation/input/devices/cma3000_d0x.rst b/Documentation/input/devices/cma3000_d0x.rst new file mode 100644 index 000000000..8bc8e6148 --- /dev/null +++ b/Documentation/input/devices/cma3000_d0x.rst @@ -0,0 +1,139 @@ +CMA3000-D0x Accelerometer +========================= + +Supported chips: +* VTI CMA3000-D0x + +Datasheet: + CMA3000-D0X Product Family Specification 8281000A.02.pdf + <http://www.vti.fi/en/> + +:Author: Hemanth V <hemanthv@ti.com> + + +Description +----------- + +CMA3000 Tri-axis accelerometer supports Motion detect, Measurement and +Free fall modes. + +Motion Detect Mode: + Its the low power mode where interrupts are generated only + when motion exceeds the defined thresholds. + +Measurement Mode: + This mode is used to read the acceleration data on X,Y,Z + axis and supports 400, 100, 40 Hz sample frequency. + +Free fall Mode: + This mode is intended to save system resources. + +Threshold values: + Chip supports defining threshold values for above modes + which includes time and g value. Refer product specifications for + more details. + +CMA3000 chip supports mutually exclusive I2C and SPI interfaces for +communication, currently the driver supports I2C based communication only. +Initial configuration for bus mode is set in non volatile memory and can later +be modified through bus interface command. + +Driver reports acceleration data through input subsystem. It generates ABS_MISC +event with value 1 when free fall is detected. + +Platform data need to be configured for initial default values. + +Platform Data +------------- + +fuzz_x: + Noise on X Axis + +fuzz_y: + Noise on Y Axis + +fuzz_z: + Noise on Z Axis + +g_range: + G range in milli g i.e 2000 or 8000 + +mode: + Default Operating mode + +mdthr: + Motion detect g range threshold value + +mdfftmr: + Motion detect and free fall time threshold value + +ffthr: + Free fall g range threshold value + +Input Interface +--------------- + +Input driver version is 1.0.0 +Input device ID: bus 0x18 vendor 0x0 product 0x0 version 0x0 +Input device name: "cma3000-accelerometer" + +Supported events:: + + Event type 0 (Sync) + Event type 3 (Absolute) + Event code 0 (X) + Value 47 + Min -8000 + Max 8000 + Fuzz 200 + Event code 1 (Y) + Value -28 + Min -8000 + Max 8000 + Fuzz 200 + Event code 2 (Z) + Value 905 + Min -8000 + Max 8000 + Fuzz 200 + Event code 40 (Misc) + Value 0 + Min 0 + Max 1 + Event type 4 (Misc) + + +Register/Platform parameters Description +---------------------------------------- + +mode:: + + 0: power down mode + 1: 100 Hz Measurement mode + 2: 400 Hz Measurement mode + 3: 40 Hz Measurement mode + 4: Motion Detect mode (default) + 5: 100 Hz Free fall mode + 6: 40 Hz Free fall mode + 7: Power off mode + +grange:: + + 2000: 2000 mg or 2G Range + 8000: 8000 mg or 8G Range + +mdthr:: + + X: X * 71mg (8G Range) + X: X * 18mg (2G Range) + +mdfftmr:: + + X: (X & 0x70) * 100 ms (MDTMR) + (X & 0x0F) * 2.5 ms (FFTMR 400 Hz) + (X & 0x0F) * 10 ms (FFTMR 100 Hz) + +ffthr:: + + X: (X >> 2) * 18mg (2G Range) + X: (X & 0x0F) * 71 mg (8G Range) |