diff options
author | Daniel Baumann <daniel.baumann@progress-linux.org> | 2024-05-08 04:17:39 +0000 |
---|---|---|
committer | Daniel Baumann <daniel.baumann@progress-linux.org> | 2024-05-08 04:17:39 +0000 |
commit | a51ea39b76ddbe91aa5ccf9f24762ef7c8b0d0cd (patch) | |
tree | 13f5692a56e72fd7da499f399ec0f91e68905c40 /tools/perf/pmu-events | |
parent | Adding debian version 4.19.282-1. (diff) | |
download | linux-a51ea39b76ddbe91aa5ccf9f24762ef7c8b0d0cd.tar.xz linux-a51ea39b76ddbe91aa5ccf9f24762ef7c8b0d0cd.zip |
Merging upstream version 4.19.289.
Signed-off-by: Daniel Baumann <daniel.baumann@progress-linux.org>
Diffstat (limited to 'tools/perf/pmu-events')
-rw-r--r-- | tools/perf/pmu-events/arch/powerpc/power9/other.json | 4 | ||||
-rw-r--r-- | tools/perf/pmu-events/arch/powerpc/power9/pipeline.json | 2 |
2 files changed, 3 insertions, 3 deletions
diff --git a/tools/perf/pmu-events/arch/powerpc/power9/other.json b/tools/perf/pmu-events/arch/powerpc/power9/other.json index 48cf4f920..064341c0d 100644 --- a/tools/perf/pmu-events/arch/powerpc/power9/other.json +++ b/tools/perf/pmu-events/arch/powerpc/power9/other.json @@ -1417,7 +1417,7 @@ {, "EventCode": "0x45054", "EventName": "PM_FMA_CMPL", - "BriefDescription": "two flops operation completed (fmadd, fnmadd, fmsub, fnmsub) Scalar instructions only. " + "BriefDescription": "two flops operation completed (fmadd, fnmadd, fmsub, fnmsub) Scalar instructions only." }, {, "EventCode": "0x201E8", @@ -2017,7 +2017,7 @@ {, "EventCode": "0xC0BC", "EventName": "PM_LSU_FLUSH_OTHER", - "BriefDescription": "Other LSU flushes including: Sync (sync ack from L2 caused search of LRQ for oldest snooped load, This will either signal a Precise Flush of the oldest snooped loa or a Flush Next PPC); Data Valid Flush Next (several cases of this, one example is store and reload are lined up such that a store-hit-reload scenario exists and the CDF has already launched and has gotten bad/stale data); Bad Data Valid Flush Next (might be a few cases of this, one example is a larxa (D$ hit) return data and dval but can't allocate to LMQ (LMQ full or other reason). Already gave dval but can't watch it for snoop_hit_larx. Need to take the “bad dval” back and flush all younger ops)" + "BriefDescription": "Other LSU flushes including: Sync (sync ack from L2 caused search of LRQ for oldest snooped load, This will either signal a Precise Flush of the oldest snooped loa or a Flush Next PPC); Data Valid Flush Next (several cases of this, one example is store and reload are lined up such that a store-hit-reload scenario exists and the CDF has already launched and has gotten bad/stale data); Bad Data Valid Flush Next (might be a few cases of this, one example is a larxa (D$ hit) return data and dval but can't allocate to LMQ (LMQ full or other reason). Already gave dval but can't watch it for snoop_hit_larx. Need to take the 'bad dval' back and flush all younger ops)" }, {, "EventCode": "0x5094", diff --git a/tools/perf/pmu-events/arch/powerpc/power9/pipeline.json b/tools/perf/pmu-events/arch/powerpc/power9/pipeline.json index b4772f54a..e2f2ed0a3 100644 --- a/tools/perf/pmu-events/arch/powerpc/power9/pipeline.json +++ b/tools/perf/pmu-events/arch/powerpc/power9/pipeline.json @@ -442,7 +442,7 @@ {, "EventCode": "0x4D052", "EventName": "PM_2FLOP_CMPL", - "BriefDescription": "DP vector version of fmul, fsub, fcmp, fsel, fabs, fnabs, fres ,fsqrte, fneg " + "BriefDescription": "DP vector version of fmul, fsub, fcmp, fsel, fabs, fnabs, fres ,fsqrte, fneg" }, {, "EventCode": "0x1F142", |