From 76cb841cb886eef6b3bee341a2266c76578724ad Mon Sep 17 00:00:00 2001 From: Daniel Baumann Date: Mon, 6 May 2024 03:02:30 +0200 Subject: Adding upstream version 4.19.249. Signed-off-by: Daniel Baumann --- Documentation/hwmon/max16064 | 66 ++++++++++++++++++++++++++++++++++++++++++++ 1 file changed, 66 insertions(+) create mode 100644 Documentation/hwmon/max16064 (limited to 'Documentation/hwmon/max16064') diff --git a/Documentation/hwmon/max16064 b/Documentation/hwmon/max16064 new file mode 100644 index 000000000..265370f5c --- /dev/null +++ b/Documentation/hwmon/max16064 @@ -0,0 +1,66 @@ +Kernel driver max16064 +====================== + +Supported chips: + * Maxim MAX16064 + Prefix: 'max16064' + Addresses scanned: - + Datasheet: http://datasheets.maxim-ic.com/en/ds/MAX16064.pdf + +Author: Guenter Roeck + + +Description +----------- + +This driver supports hardware monitoring for Maxim MAX16064 Quad Power-Supply +Controller with Active-Voltage Output Control and PMBus Interface. + +The driver is a client driver to the core PMBus driver. +Please see Documentation/hwmon/pmbus for details on PMBus client drivers. + + +Usage Notes +----------- + +This driver does not auto-detect devices. You will have to instantiate the +devices explicitly. Please see Documentation/i2c/instantiating-devices for +details. + + +Platform data support +--------------------- + +The driver supports standard PMBus driver platform data. + + +Sysfs entries +------------- + +The following attributes are supported. Limits are read-write; all other +attributes are read-only. + +in[1-4]_label "vout[1-4]" +in[1-4]_input Measured voltage. From READ_VOUT register. +in[1-4]_min Minimum Voltage. From VOUT_UV_WARN_LIMIT register. +in[1-4]_max Maximum voltage. From VOUT_OV_WARN_LIMIT register. +in[1-4]_lcrit Critical minimum Voltage. VOUT_UV_FAULT_LIMIT register. +in[1-4]_crit Critical maximum voltage. From VOUT_OV_FAULT_LIMIT register. +in[1-4]_min_alarm Voltage low alarm. From VOLTAGE_UV_WARNING status. +in[1-4]_max_alarm Voltage high alarm. From VOLTAGE_OV_WARNING status. +in[1-4]_lcrit_alarm Voltage critical low alarm. From VOLTAGE_UV_FAULT status. +in[1-4]_crit_alarm Voltage critical high alarm. From VOLTAGE_OV_FAULT status. +in[1-4]_highest Historical maximum voltage. +in[1-4]_reset_history Write any value to reset history. + +temp1_input Measured temperature. From READ_TEMPERATURE_1 register. +temp1_max Maximum temperature. From OT_WARN_LIMIT register. +temp1_crit Critical high temperature. From OT_FAULT_LIMIT register. +temp1_max_alarm Chip temperature high alarm. Set by comparing + READ_TEMPERATURE_1 with OT_WARN_LIMIT if TEMP_OT_WARNING + status is set. +temp1_crit_alarm Chip temperature critical high alarm. Set by comparing + READ_TEMPERATURE_1 with OT_FAULT_LIMIT if TEMP_OT_FAULT + status is set. +temp1_highest Historical maximum temperature. +temp1_reset_history Write any value to reset history. -- cgit v1.2.3