diff options
Diffstat (limited to '')
-rw-r--r-- | bin/tests/system/builtin/clean.sh | 17 | ||||
-rw-r--r-- | bin/tests/system/builtin/ns1/named.conf.in | 28 | ||||
-rw-r--r-- | bin/tests/system/builtin/ns2/named.conf.in | 29 | ||||
-rw-r--r-- | bin/tests/system/builtin/ns3/named.conf.in | 31 | ||||
-rw-r--r-- | bin/tests/system/builtin/setup.sh | 18 | ||||
-rw-r--r-- | bin/tests/system/builtin/tests.sh | 242 |
6 files changed, 365 insertions, 0 deletions
diff --git a/bin/tests/system/builtin/clean.sh b/bin/tests/system/builtin/clean.sh new file mode 100644 index 0000000..93a1115 --- /dev/null +++ b/bin/tests/system/builtin/clean.sh @@ -0,0 +1,17 @@ +#!/bin/sh +# +# Copyright (C) Internet Systems Consortium, Inc. ("ISC") +# +# This Source Code Form is subject to the terms of the Mozilla Public +# License, v. 2.0. If a copy of the MPL was not distributed with this +# file, You can obtain one at http://mozilla.org/MPL/2.0/. +# +# See the COPYRIGHT file distributed with this work for additional +# information regarding copyright ownership. + +rm -f ns?/named.run +rm -f ns?/named.memstats +rm -f ns?/named.conf +rm -f rndc.status.ns* +rm -f dig.out.ns* +rm -f ns*/named.lock diff --git a/bin/tests/system/builtin/ns1/named.conf.in b/bin/tests/system/builtin/ns1/named.conf.in new file mode 100644 index 0000000..d181a36 --- /dev/null +++ b/bin/tests/system/builtin/ns1/named.conf.in @@ -0,0 +1,28 @@ +/* + * Copyright (C) Internet Systems Consortium, Inc. ("ISC") + * + * This Source Code Form is subject to the terms of the Mozilla Public + * License, v. 2.0. If a copy of the MPL was not distributed with this + * file, You can obtain one at http://mozilla.org/MPL/2.0/. + * + * See the COPYRIGHT file distributed with this work for additional + * information regarding copyright ownership. + */ + +include "../../common/rndc.key"; + +controls { + inet 10.53.0.1 port @CONTROLPORT@ allow { any; } keys { rndc_key; }; +}; + +options { + query-source address 10.53.0.1; + notify-source 10.53.0.1; + transfer-source 10.53.0.1; + port @PORT@; + pid-file "named.pid"; + listen-on { 10.53.0.1; }; + listen-on-v6 { none; }; + recursion yes; + notify no; +}; diff --git a/bin/tests/system/builtin/ns2/named.conf.in b/bin/tests/system/builtin/ns2/named.conf.in new file mode 100644 index 0000000..e875a92 --- /dev/null +++ b/bin/tests/system/builtin/ns2/named.conf.in @@ -0,0 +1,29 @@ +/* + * Copyright (C) Internet Systems Consortium, Inc. ("ISC") + * + * This Source Code Form is subject to the terms of the Mozilla Public + * License, v. 2.0. If a copy of the MPL was not distributed with this + * file, You can obtain one at http://mozilla.org/MPL/2.0/. + * + * See the COPYRIGHT file distributed with this work for additional + * information regarding copyright ownership. + */ + +include "../../common/rndc.key"; + +controls { + inet 10.53.0.2 port @CONTROLPORT@ allow { any; } keys { rndc_key; }; +}; + +options { + query-source address 10.53.0.2; + notify-source 10.53.0.2; + transfer-source 10.53.0.2; + port @PORT@; + pid-file "named.pid"; + listen-on { 10.53.0.2; }; + listen-on-v6 { none; }; + recursion yes; + notify no; + server-id hostname; +}; diff --git a/bin/tests/system/builtin/ns3/named.conf.in b/bin/tests/system/builtin/ns3/named.conf.in new file mode 100644 index 0000000..4bce9f7 --- /dev/null +++ b/bin/tests/system/builtin/ns3/named.conf.in @@ -0,0 +1,31 @@ +/* + * Copyright (C) Internet Systems Consortium, Inc. ("ISC") + * + * This Source Code Form is subject to the terms of the Mozilla Public + * License, v. 2.0. If a copy of the MPL was not distributed with this + * file, You can obtain one at http://mozilla.org/MPL/2.0/. + * + * See the COPYRIGHT file distributed with this work for additional + * information regarding copyright ownership. + */ + +include "../../common/rndc.key"; + +controls { + inet 10.53.0.3 port @CONTROLPORT@ allow { any; } keys { rndc_key; }; +}; + +options { + query-source address 10.53.0.3; + notify-source 10.53.0.3; + transfer-source 10.53.0.3; + port @PORT@; + pid-file "named.pid"; + listen-on { 10.53.0.3; }; + listen-on-v6 { none; }; + recursion yes; + notify no; + hostname "this.is.a.test.of.hostname"; + server-id "this.is.a.test.of.server-id"; + version "this is a test of version"; +}; diff --git a/bin/tests/system/builtin/setup.sh b/bin/tests/system/builtin/setup.sh new file mode 100644 index 0000000..c9f645b --- /dev/null +++ b/bin/tests/system/builtin/setup.sh @@ -0,0 +1,18 @@ +#!/bin/sh +# +# Copyright (C) Internet Systems Consortium, Inc. ("ISC") +# +# This Source Code Form is subject to the terms of the Mozilla Public +# License, v. 2.0. If a copy of the MPL was not distributed with this +# file, You can obtain one at http://mozilla.org/MPL/2.0/. +# +# See the COPYRIGHT file distributed with this work for additional +# information regarding copyright ownership. + +SYSTEMTESTTOP=.. +. $SYSTEMTESTTOP/conf.sh + +$SHELL clean.sh +copy_setports ns1/named.conf.in ns1/named.conf +copy_setports ns2/named.conf.in ns2/named.conf +copy_setports ns3/named.conf.in ns3/named.conf diff --git a/bin/tests/system/builtin/tests.sh b/bin/tests/system/builtin/tests.sh new file mode 100644 index 0000000..391c239 --- /dev/null +++ b/bin/tests/system/builtin/tests.sh @@ -0,0 +1,242 @@ +# Copyright (C) Internet Systems Consortium, Inc. ("ISC") +# +# This Source Code Form is subject to the terms of the Mozilla Public +# License, v. 2.0. If a copy of the MPL was not distributed with this +# file, You can obtain one at http://mozilla.org/MPL/2.0/. +# +# See the COPYRIGHT file distributed with this work for additional +# information regarding copyright ownership. + +SYSTEMTESTTOP=.. +. $SYSTEMTESTTOP/conf.sh + +DIGOPTS="-p ${PORT}" +RNDCCMD="$RNDC -c $SYSTEMTESTTOP/common/rndc.conf -p ${CONTROLPORT} -s" + +status=0 +n=0 + +emptyzones=" +10.IN-ADDR.ARPA +16.172.IN-ADDR.ARPA +17.172.IN-ADDR.ARPA +18.172.IN-ADDR.ARPA +19.172.IN-ADDR.ARPA +20.172.IN-ADDR.ARPA +21.172.IN-ADDR.ARPA +22.172.IN-ADDR.ARPA +23.172.IN-ADDR.ARPA +24.172.IN-ADDR.ARPA +25.172.IN-ADDR.ARPA +26.172.IN-ADDR.ARPA +27.172.IN-ADDR.ARPA +28.172.IN-ADDR.ARPA +29.172.IN-ADDR.ARPA +30.172.IN-ADDR.ARPA +31.172.IN-ADDR.ARPA +168.192.IN-ADDR.ARPA +64.100.IN-ADDR.ARPA +65.100.IN-ADDR.ARPA +66.100.IN-ADDR.ARPA +67.100.IN-ADDR.ARPA +68.100.IN-ADDR.ARPA +69.100.IN-ADDR.ARPA +70.100.IN-ADDR.ARPA +71.100.IN-ADDR.ARPA +72.100.IN-ADDR.ARPA +73.100.IN-ADDR.ARPA +74.100.IN-ADDR.ARPA +75.100.IN-ADDR.ARPA +76.100.IN-ADDR.ARPA +77.100.IN-ADDR.ARPA +78.100.IN-ADDR.ARPA +79.100.IN-ADDR.ARPA +80.100.IN-ADDR.ARPA +81.100.IN-ADDR.ARPA +82.100.IN-ADDR.ARPA +83.100.IN-ADDR.ARPA +84.100.IN-ADDR.ARPA +85.100.IN-ADDR.ARPA +86.100.IN-ADDR.ARPA +87.100.IN-ADDR.ARPA +88.100.IN-ADDR.ARPA +89.100.IN-ADDR.ARPA +90.100.IN-ADDR.ARPA +91.100.IN-ADDR.ARPA +92.100.IN-ADDR.ARPA +93.100.IN-ADDR.ARPA +94.100.IN-ADDR.ARPA +95.100.IN-ADDR.ARPA +96.100.IN-ADDR.ARPA +97.100.IN-ADDR.ARPA +98.100.IN-ADDR.ARPA +99.100.IN-ADDR.ARPA +100.100.IN-ADDR.ARPA +101.100.IN-ADDR.ARPA +102.100.IN-ADDR.ARPA +103.100.IN-ADDR.ARPA +104.100.IN-ADDR.ARPA +105.100.IN-ADDR.ARPA +106.100.IN-ADDR.ARPA +107.100.IN-ADDR.ARPA +108.100.IN-ADDR.ARPA +109.100.IN-ADDR.ARPA +110.100.IN-ADDR.ARPA +111.100.IN-ADDR.ARPA +112.100.IN-ADDR.ARPA +113.100.IN-ADDR.ARPA +114.100.IN-ADDR.ARPA +115.100.IN-ADDR.ARPA +116.100.IN-ADDR.ARPA +117.100.IN-ADDR.ARPA +118.100.IN-ADDR.ARPA +119.100.IN-ADDR.ARPA +120.100.IN-ADDR.ARPA +121.100.IN-ADDR.ARPA +122.100.IN-ADDR.ARPA +123.100.IN-ADDR.ARPA +124.100.IN-ADDR.ARPA +125.100.IN-ADDR.ARPA +126.100.IN-ADDR.ARPA +127.100.IN-ADDR.ARPA +0.IN-ADDR.ARPA +127.IN-ADDR.ARPA +254.169.IN-ADDR.ARPA +2.0.192.IN-ADDR.ARPA +100.51.198.IN-ADDR.ARPA +113.0.203.IN-ADDR.ARPA +255.255.255.255.IN-ADDR.ARPA +0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.IP6.ARPA +1.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.IP6.ARPA +D.F.IP6.ARPA +8.E.F.IP6.ARPA +9.E.F.IP6.ARPA +A.E.F.IP6.ARPA +B.E.F.IP6.ARPA +8.B.D.0.1.0.0.2.IP6.ARPA +EMPTY.AS112.ARPA +HOME.ARPA" + +n=`expr $n + 1` +ret=0 +count=0 +echo_i "Checking expected empty zones were configured ($n)" +for zone in ${emptyzones} +do + grep "automatic empty zone: $zone" ns1/named.run > /dev/null || { + echo_i "failed (empty zone $zone missing)" + ret=1 + } + count=`expr $count + 1` +done +lines=`grep "automatic empty zone: " ns1/named.run | wc -l` +test $count -eq $lines -a $count -eq 99 || { + ret=1; echo_i "failed (count mismatch)"; +} +if [ $ret != 0 ] ; then status=`expr $status + $ret`; fi + +n=`expr $n + 1` +echo_i "Checking that reconfiguring empty zones is silent ($n)" +$RNDCCMD 10.53.0.1 reconfig +ret=0 +grep "automatic empty zone" ns1/named.run > /dev/null || ret=1 +grep "received control channel command 'reconfig'" ns1/named.run > /dev/null || ret=1 +grep "reloading configuration succeeded" ns1/named.run > /dev/null || ret=1 +sleep 1 +grep "zone serial (0) unchanged." ns1/named.run > /dev/null && ret=1 +if [ $ret != 0 ] ; then echo_i "failed"; status=`expr $status + $ret`; fi + +n=`expr $n + 1` +echo_i "Checking that reloading empty zones is silent ($n)" +$RNDCCMD 10.53.0.1 reload > /dev/null +ret=0 +grep "automatic empty zone" ns1/named.run > /dev/null || ret=1 +grep "received control channel command 'reload'" ns1/named.run > /dev/null || ret=1 +grep "reloading configuration succeeded" ns1/named.run > /dev/null || ret=1 +sleep 1 +grep "zone serial (0) unchanged." ns1/named.run > /dev/null && ret=1 +if [ $ret != 0 ] ; then echo_i "failed"; status=`expr $status + $ret`; fi + +VERSION=`../../../../isc-config.sh --version | cut -d = -f 2` +HOSTNAME=`$FEATURETEST --gethostname` + +n=`expr $n + 1` +ret=0 +echo_i "Checking that default version works for rndc ($n)" +$RNDCCMD 10.53.0.1 status > rndc.status.ns1.$n 2>&1 +grep "^version: BIND $VERSION " rndc.status.ns1.$n > /dev/null || ret=1 +if [ $ret != 0 ] ; then echo_i "failed"; status=`expr $status + $ret`; fi + +n=`expr $n + 1` +ret=0 +echo_i "Checking that custom version works for rndc ($n)" +$RNDCCMD 10.53.0.3 status > rndc.status.ns3.$n 2>&1 +grep "^version: BIND $VERSION ${DESCRIPTION}${DESCRIPTION:+ }<id:........*> (this is a test of version)" rndc.status.ns3.$n > /dev/null || ret=1 +if [ $ret != 0 ] ; then echo_i "failed"; status=`expr $status + $ret`; fi + +n=`expr $n + 1` +ret=0 +echo_i "Checking that default version works for query ($n)" +$DIG $DIGOPTS +short version.bind txt ch @10.53.0.1 > dig.out.ns1.$n +grep "^\"$VERSION\"$" dig.out.ns1.$n > /dev/null || ret=1 +if [ $ret != 0 ] ; then echo_i "failed"; status=`expr $status + $ret`; fi + +n=`expr $n + 1` +ret=0 +echo_i "Checking that custom version works for query ($n)" +$DIG $DIGOPTS +short version.bind txt ch @10.53.0.3 > dig.out.ns3.$n +grep "^\"this is a test of version\"$" dig.out.ns3.$n > /dev/null || ret=1 +if [ $ret != 0 ] ; then echo_i "failed"; status=`expr $status + $ret`; fi + +n=`expr $n + 1` +ret=0 +echo_i "Checking that default hostname works for query ($n)" +$DIG $DIGOPTS +short hostname.bind txt ch @10.53.0.1 > dig.out.ns1.$n +grep "^\"$HOSTNAME\"$" dig.out.ns1.$n > /dev/null || ret=1 +if [ $ret != 0 ] ; then echo_i "failed"; status=`expr $status + $ret`; fi + +n=`expr $n + 1` +ret=0 +echo_i "Checking that custom hostname works for query ($n)" +$DIG $DIGOPTS +short hostname.bind txt ch @10.53.0.3 > dig.out.ns3.$n +grep "^\"this.is.a.test.of.hostname\"$" dig.out.ns3.$n > /dev/null || ret=1 +if [ $ret != 0 ] ; then echo_i "failed"; status=`expr $status + $ret`; fi + +n=`expr $n + 1` +ret=0 +echo_i "Checking that default server-id is none for query ($n)" +$DIG $DIGOPTS id.server txt ch @10.53.0.1 > dig.out.ns1.$n +grep "status: NOERROR" dig.out.ns1.$n > /dev/null || ret=1 +grep "ANSWER: 0" dig.out.ns1.$n > /dev/null || ret=1 +if [ $ret != 0 ] ; then echo_i "failed"; status=`expr $status + $ret`; fi + +n=`expr $n + 1` +ret=0 +echo_i "Checking that server-id hostname works for query ($n)" +$DIG $DIGOPTS +short id.server txt ch @10.53.0.2 > dig.out.ns2.$n +grep "^\"$HOSTNAME\"$" dig.out.ns2.$n > /dev/null || ret=1 +if [ $ret != 0 ] ; then echo_i "failed"; status=`expr $status + $ret`; fi + +n=`expr $n + 1` +ret=0 +echo_i "Checking that server-id hostname works for EDNS name server ID request ($n)" +$DIG $DIGOPTS +norec +nsid foo @10.53.0.2 > dig.out.ns2.$n +grep "^; NSID: .* (\"$HOSTNAME\")$" dig.out.ns2.$n > /dev/null || ret=1 +if [ $ret != 0 ] ; then echo_i "failed"; status=`expr $status + $ret`; fi + +n=`expr $n + 1` +ret=0 +echo_i "Checking that custom server-id works for query ($n)" +$DIG $DIGOPTS +short id.server txt ch @10.53.0.3 > dig.out.ns3.$n +grep "^\"this.is.a.test.of.server-id\"$" dig.out.ns3.$n > /dev/null || ret=1 +if [ $ret != 0 ] ; then echo_i "failed"; status=`expr $status + $ret`; fi + +n=`expr $n + 1` +ret=0 +echo_i "Checking that custom server-id works for EDNS name server ID request ($n)" +$DIG $DIGOPTS +norec +nsid foo @10.53.0.3 > dig.out.ns3.$n +grep "^; NSID: .* (\"this.is.a.test.of.server-id\")$" dig.out.ns3.$n > /dev/null || ret=1 +if [ $ret != 0 ] ; then echo_i "failed"; status=`expr $status + $ret`; fi + +echo_i "exit status: $status" +[ $status -eq 0 ] || exit 1 |