// This file is part of chrony // // Copyright (C) Richard P. Curnow 1997-2003 // Copyright (C) Miroslav Lichvar 2014-2016, 2020 // // This program is free software; you can redistribute it and/or modify // it under the terms of version 2 of the GNU General Public License as // published by the Free Software Foundation. // // This program is distributed in the hope that it will be useful, but // WITHOUT ANY WARRANTY; without even the implied warranty of // MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the GNU // General Public License for more details. // // You should have received a copy of the GNU General Public License along // with this program; if not, write to the Free Software Foundation, Inc., // 51 Franklin Street, Fifth Floor, Boston, MA 02110-1301, USA. = Frequently Asked Questions :toc: :numbered: == `chrony` compared to other programs === How does `chrony` compare to `ntpd`? `chrony` and `ntpd` are two different implementations of the Network Time Protocol (NTP). `chrony` is a newer implementation, which was designed to work well in a wider range of conditions. It can usually synchronise the system clock faster and with better time accuracy. It has many features, but it does not implement some of the less useful NTP modes like broadcast client or multicast server/client. If your computer is connected to the Internet only for few minutes at a time, the network connection is often congested, you turn your computer off or suspend it frequently, the clock is not very stable (e.g. there are rapid changes in the temperature or it is a virtual machine), or you want to use NTP on an isolated network with no hardware reference clocks in sight, `chrony` will probably work better for you. For a more detailed comparison of features and performance, see the https://chrony.tuxfamily.org/comparison.html[comparison page] on the `chrony` website. == Configuration issues === What is the minimum recommended configuration for an NTP client? First, the client needs to know which NTP servers it should ask for the current time. They are specified by the `server` or `pool` directive. The `pool` directive can be used for names that resolve to multiple addresses. For good reliability the client should have at least three servers. The `iburst` option speeds up the initial synchronisation. To stabilise the initial synchronisation on the next start, the estimated drift of the system clock is saved to a file specified by the `driftfile` directive. If the system clock can be far from the true time after boot for any reason, `chronyd` should be allowed to correct it quickly by stepping instead of slewing, which would take a very long time. The `makestep` directive does that. In order to keep the real-time clock (RTC) close to the true time, so the system time is reasonably close to the true time when it is initialised on the next boot from the RTC, the `rtcsync` directive enables a mode in which the system time is periodically copied to the RTC. It is supported on Linux and macOS. If you want to use public NTP servers from the https://www.pool.ntp.org/[pool.ntp.org] project, the minimal _chrony.conf_ file could be: ---- pool pool.ntp.org iburst driftfile /var/lib/chrony/drift makestep 1 3 rtcsync ---- === How do I make an NTP server? You need to add an `allow` directive to the _chrony.conf_ file in order to open the NTP port and allow `chronyd` to reply to client requests. `allow` with no specified subnet allows access from all IPv4 and IPv6 addresses. === Should all computers on a LAN be clients of an external server? It depends on the requirements. Usually, the best configuration is to make one computer the server, with the others as clients of it. Add a `local` directive to the server's _chrony.conf_ file. This configuration will be better because * the load on the external connection is less * the load on the external NTP server(s) is less * if your external connection goes down, the computers on the LAN will maintain a common time with each other. === Must I specify servers by IP address if DNS is not available on `chronyd` start? No, `chronyd` will keep trying to resolve the names specified by the `server`, `pool`, and `peer` directives in an increasing interval until it succeeds. The `online` command can be issued from `chronyc` to force `chronyd` to try to resolve the names immediately. === How can I make `chronyd` more secure? If you do not need to use `chronyc`, or you want to run `chronyc` only under the root or _chrony_ user (which can access `chronyd` through a Unix domain socket), you can disable the IPv4 and IPv6 command sockets (by default listening on localhost) by adding `cmdport 0` to the configuration file. You can specify an unprivileged user with the `-u` option, or the `user` directive in the _chrony.conf_ file, to which `chronyd` will switch after start in order to drop root privileges. The configure script has a `--with-user` option, which sets the default user. On Linux, `chronyd` needs to be compiled with support for the `libcap` library. On other systems, `chronyd` forks into two processes. The child process retains root privileges, but can only perform a very limited range of privileged system calls on behalf of the parent. Also, if `chronyd` is compiled with support for the Linux secure computing (seccomp) facility, you can enable a system call filter with the `-F` option. It will significantly reduce the kernel attack surface and possibly prevent kernel exploits from the `chronyd` process if it is compromised. It is recommended to enable the filter only when it is known to work on the version of the system where `chrony` is installed as the filter needs to allow also system calls made from libraries that `chronyd` is using (e.g. libc) and different versions or implementations of the libraries might make different system calls. If the filter is missing some system call, `chronyd` could be killed even in normal operation. === How can I improve the accuracy of the system clock with NTP sources? Select NTP servers that are well synchronised, stable and close to your network. It is better to use more than one server, three or four is usually recommended as the minimum, so `chronyd` can detect servers that serve false time and combine measurements from multiple sources. If you have a network card with hardware timestamping supported on Linux, it can be enabled by the `hwtimestamp` directive in the _chrony.conf_ file. It should make local receive and transmit timestamps of NTP packets much more accurate. There are also useful options which can be set in the `server` directive, they are `minpoll`, `maxpoll`, `polltarget`, `maxdelay`, `maxdelayratio`, `maxdelaydevratio`, and `xleave`. The first three options set the minimum and maximum allowed polling interval, and how should be the actual interval adjusted in the specified range. Their default values are 6 (64 seconds) for `minpoll`, 10 (1024 seconds) for `maxpoll` and 8 (samples) for `polltarget`. The default values should be used for general servers on the Internet. With your own NTP servers, or if you have permission to poll some servers more frequently, setting these options for shorter polling intervals might significantly improve the accuracy of the system clock. The optimal polling interval depends mainly on two factors, stability of the network latency and stability of the system clock (which mainly depends on the temperature sensitivity of the crystal oscillator and the maximum rate of the temperature change). Generally, if the `sourcestats` command usually reports a small number of samples retained for a source (e.g. fewer than 16), a shorter polling interval should be considered. If the number of samples is usually at the maximum of 64, a longer polling interval might work better. An example of the directive for an NTP server on the Internet that you are allowed to poll frequently could be ---- server foo.example.net minpoll 4 maxpoll 6 polltarget 16 ---- An example using shorter polling intervals with a server located in the same LAN could be ---- server ntp.local minpoll 2 maxpoll 4 polltarget 30 ---- The maxdelay options are useful to ignore measurements with an unusally large delay (e.g. due to congestion in the network) and improve the stability of the synchronisation. The `maxdelaydevratio` option could be added to the example with local NTP server ---- server ntp.local minpoll 2 maxpoll 4 polltarget 30 maxdelaydevratio 2 ---- If your server supports the interleaved mode (e.g. it is running `chronyd`), the `xleave` option should be added to the `server` directive in order to allow the server to send the client more accurate transmit timestamps (kernel or preferably hardware). For example: ---- server ntp.local minpoll 2 maxpoll 4 xleave ---- When combined with local hardware timestamping, good network switches, and even shorter polling intervals, a sub-microsecond accuracy and stability of a few tens of nanoseconds might be possible. For example: ---- server ntp.local minpoll 0 maxpoll 0 xleave hwtimestamp eth0 ---- For best stability, the CPU should be running at a constant frequency (i.e. disabled power saving and performance boosting). Energy-Efficient Ethernet (EEE) should be disabled in the network. The switches should be configured to prioritize NTP packets, especially if the network is expected to be heavily loaded. The `dscp` directive can be used to set the Differentiated Services Code Point in transmitted NTP packets if needed. If it is acceptable for NTP clients in the network to send requests at a high rate, a sub-second polling interval can be specified. A median filter can be enabled in order to update the clock at a reduced rate with more stable measurements. For example: ---- server ntp.local minpoll -6 maxpoll -6 filter 15 xleave hwtimestamp eth0 minpoll -6 ---- === Does `chronyd` have an ntpdate mode? Yes. With the `-q` option `chronyd` will set the system clock once and exit. With the `-Q` option it will print the measured offset without setting the clock. If you do not want to use a configuration file, NTP servers can be specified on the command line. For example: ---- # chronyd -q 'pool pool.ntp.org iburst' ---- The command above would normally take about 5 seconds if the servers were well synchronised and responding to all requests. If not synchronised or responding, it would take about 10 seconds for `chronyd` to give up and exit with a non-zero status. A faster configuration is possible. A single server can be used instead of four servers, the number of measurements can be reduced with the `maxsamples` option to one (supported in `chrony` version 4.0), and a timeout can be specified with the `-t` option. The following command would take only up to about one second. ---- # chronyd -q -t 1 'server pool.ntp.org iburst maxsamples 1' ---- It is not recommended to run `chronyd` with the `-q` option periodically (e.g. from a cron job) as a replacement for the daemon mode, because it performs significantly worse (e.g. the clock is stepped and its frequency is not corrected). If you must run it this way and you are using a public NTP server, make sure `chronyd` does not always start around the first second of a minute, e.g. by adding a random sleep before the `chronyd` command. Public servers typically receive large bursts of requests around the first second as there is a large number of NTP clients started from cron with no delay. === Can `chronyd` be configured to control the clock like `ntpd`? It is not possible to perfectly emulate `ntpd`, but there are some options that can configure `chronyd` to behave more like `ntpd` if there is a reason to prefer that. In the following example the `minsamples` directive slows down the response to changes in the frequency and offset of the clock. The `maxslewrate` and `corrtimeratio` directives reduce the maximum frequency error due to an offset correction and the `maxdrift` directive reduces the maximum assumed frequency error of the clock. The `makestep` directive enables a step threshold and the `maxchange` directive enables a panic threshold. The `maxclockerror` directive increases the minimum dispersion rate. ---- minsamples 32 maxslewrate 500 corrtimeratio 100 maxdrift 500 makestep 0.128 -1 maxchange 1000 1 1 maxclockerror 15 ---- Note that increasing `minsamples` might cause the offsets in the `tracking` and `sourcestats` reports/logs to be significantly smaller than the actual offsets and be unsuitable for monitoring. === Can NTP server be separated from NTP client? Yes, it is possible to run multiple instances of `chronyd` on the same computer. One can be configured as an NTP client, and another as a server. They need to use different pidfiles, NTP ports, command ports, and Unix domain command sockets. The server instance should be started with the `-x` option to avoid touching the clock. It can be configured to serve the system time with the `local` directive, or synchronise its NTP clock to the client instance running on localhost using a non-standard NTP port. On Linux, starting with `chrony` version 4.0, it is also possible to run multiple server instances sharing a port to utilise multiple cores of the CPU. Note that the client/server interleaved mode requires that all packets from an address are handled by the same server instance. === Should be a leap smear enabled on NTP server? With the `smoothtime` and `leapsecmode` directives it is possible to enable a server leap smear in order to hide leap seconds from clients and force them to follow a slow server's adjustment instead. This feature should be used only in local networks and only when necessary, e.g. when the clients cannot be configured to handle the leap seconds as needed, or their number is so large that configuring them all would be impractical. The clients should use only one leap-smearing server, or multiple identically configured leap-smearing servers. Note that some clients can get leap seconds from external sources (e.g. with the `leapsectz` directive in `chrony`) and they will not work correctly with a leap smearing server. === Does `chrony` support PTP? No, the Precision Time Protocol (PTP) is not supported and there are no plans to support it. It is a complex protocol, which shares some issues with the NTP broadcast mode. One of the main differences between NTP and PTP is that PTP was designed to be easily supported in hardware (e.g. network switches and routers) in order to make more stable and accurate measurements. PTP relies on the hardware support. NTP does not rely on any support in the hardware, but if it had the same support as PTP, it could perform equally well. On Linux, `chrony` supports hardware clocks that some NICs have for PTP. They are called PTP hardware clocks (PHC). They can be used as reference clocks (specified by the `refclock` directive) and for hardware timestamping of NTP packets (enabled by the `hwtimestamp` directive) if the NIC can timestamp other packets than PTP, which is usually the case at least for transmitted packets. The `ethtool -T` command can be used to verify the timestamping support. === What happened to the `commandkey` and `generatecommandkey` directives? They were removed in version 2.2. Authentication is no longer supported in the command protocol. Commands that required authentication are now allowed only through a Unix domain socket, which is accessible only by the root and _chrony_ users. If you need to configure `chronyd` remotely or locally without the root password, please consider using ssh and/or sudo to run `chronyc` under the root or _chrony_ user on the host where `chronyd` is running. == Computer is not synchronising This is the most common problem. There are a number of reasons, see the following questions. === Behind a firewall? Check the `Reach` value printed by the ``chronyc``'s `sources` command. If it is zero, it means `chronyd` did not get any valid responses from the NTP server you are trying to use. If there is a firewall between you and the server, the packets might be blocked. Try using a tool like `wireshark` or `tcpdump` to see if you are getting any responses from the server. When `chronyd` is receiving responses from the servers, the output of the `sources` command issued few minutes after `chronyd` start might look like this: ---- 210 Number of sources = 3 MS Name/IP address Stratum Poll Reach LastRx Last sample =============================================================================== ^* foo.example.net 2 6 377 34 +484us[ -157us] +/- 30ms ^- bar.example.net 2 6 377 34 +33ms[ +32ms] +/- 47ms ^+ baz.example.net 3 6 377 35 -1397us[-2033us] +/- 60ms ---- === Are NTP servers specified with the `offline` option? Check that the ``chronyc``'s `online` and `offline` commands are used appropriately (e.g. in the system networking scripts). The `activity` command prints the number of sources that are currently online and offline. For example: ---- 200 OK 3 sources online 0 sources offline 0 sources doing burst (return to online) 0 sources doing burst (return to offline) 0 sources with unknown address ---- === Is `chronyd` allowed to step the system clock? By default, `chronyd` adjusts the clock gradually by slowing it down or speeding it up. If the clock is too far from the true time, it will take a long time to correct the error. The `System time` value printed by the ``chronyc``'s `tracking` command is the remaining correction that needs to be applied to the system clock. The `makestep` directive can be used to allow `chronyd` to step the clock. For example, if _chrony.conf_ had ---- makestep 1 3 ---- the clock would be stepped in the first three updates if its offset was larger than one second. Normally, it is recommended to allow the step only in the first few updates, but in some cases (e.g. a computer without an RTC or virtual machine which can be suspended and resumed with an incorrect time) it might be necessary to allow the step on any clock update. The example above would change to ---- makestep 1 -1 ---- === Using a Windows NTP server? A common issue with Windows NTP servers is that they report a very large root dispersion (e.g. three seconds or more), which causes `chronyd` to ignore the server for being too inaccurate. The `sources` command might show a valid measurement, but the server is not selected for synchronisation. You can check the root dispersion of the server with the ``chronyc``'s `ntpdata` command. The `maxdistance` value needs to be increased in _chrony.conf_ to enable synchronisation to such a server. For example: ---- maxdistance 16.0 ---- === An unreachable source is selected? When `chronyd` is configured with multiple time sources, it tries to select the most accurate and stable sources for synchronisation of the system clock. They are marked with the _*_ or _+_ symbol in the report printed by the `sources` command. When the best source (marked with the _*_ symbol) becomes unreachable (e.g. NTP server stops responding), `chronyd` will not immediately switch to the second best source in an attempt to minimise the error of the clock. It will let the clock run free for as long as its estimated error (in terms of root distance) based on previous measurements is smaller than the estimated error of the second source, and there is still an interval which contains some measurements from both sources. If the first source was significantly better than the second source, it can take many hours before the second source is selected, depending on its polling interval. You can force a faster reselection by increasing the clock error rate (`maxclockerror` directive), shortening the polling interval (`maxpoll` option), or reducing the number of samples (`maxsamples` option). === Does selected source drop new measurements? `chronyd` can drop a large number of successive NTP measurements if they are not passing some of the NTP tests. The `sources` command can report for a selected source the fully-reachable value of 377 in the Reach column and at the same time a LastRx value that is much larger than the current polling interval. If the source is online, this indicates that a number of measurements was dropped. You can use the `ntpdata` command to check the NTP tests for the last measurement. Usually, it is the test C which fails. This can be an issue when there is a long-lasting increase in the measured delay, e.g. due to a routing change in the network. Unfortunately, `chronyd` does not know for how long it should wait for the delay to come back to the original values, or whether it is a permanent increase and it should start from scratch. The test C is an adaptive filter. It can take many hours before it accepts a measurement with the larger delay, and even much longer before it drops all measurements with smaller delay, which determine an expected delay used by the test. You can use the `reset sources` command to drop all measurements immediately (available in chrony 4.0 and later). If this issue happens frequently, you can effectively disable the test by setting the `maxdelaydevratio` option to a very large value (e.g. 1000000), or speed up the recovery by increasing the clock error rate with the `maxclockerror` directive. === Using a PPS reference clock? A pulse-per-second (PPS) reference clock requires a non-PPS time source to determine which second of UTC corresponds to each pulse. If it is another reference clock specified with the `lock` option in the `refclock` directive, the offset between the two reference clocks must be smaller than 0.2 seconds in order for the PPS reference clock to work. With NMEA reference clocks it is common to have a larger offset. It needs to be corrected with the `offset` option. One approach to find out a good value of the `offset` option is to configure the reference clocks with the `noselect` option and compare them to an NTP server. For example, if the `sourcestats` command showed ---- Name/IP Address NP NR Span Frequency Freq Skew Offset Std Dev ============================================================================== PPS0 0 0 0 +0.000 2000.000 +0ns 4000ms NMEA 58 30 231 -96.494 38.406 +504ms 6080us foo.example.net 7 3 200 -2.991 16.141 -107us 492us ---- the offset of the NMEA source would need to be increased by about 0.504 seconds. It does not have to be very accurate. As long as the offset of the NMEA reference clock stays below 0.2 seconds, the PPS reference clock should be able to determine the seconds corresponding to the pulses and allow the samples to be used for synchronisation. == Issues with `chronyc` === I keep getting the error `506 Cannot talk to daemon` When accessing `chronyd` remotely, make sure that the _chrony.conf_ file (on the computer where `chronyd` is running) has a `cmdallow` entry for the computer you are running `chronyc` on and an appropriate `bindcmdaddress` directive. This is not necessary for localhost. Perhaps `chronyd` is not running. Try using the `ps` command (e.g. on Linux, `ps -auxw`) to see if it is running. Or try `netstat -a` and see if the UDP port 323 is listening. If `chronyd` is not running, you might have a problem with the way you are trying to start it (e.g. at boot time). Perhaps you have a firewall set up in a way that blocks packets on the UDP port 323. You need to amend the firewall configuration in this case. === I keep getting the error `501 Not authorised` This error indicates that `chronyc` sent the command to `chronyd` using a UDP socket instead of the Unix domain socket (e.g. _/var/run/chrony/chronyd.sock_), which is required for some commands. For security reasons, only the root and _chrony_ users are allowed to access the socket. It is also possible that the socket does not exist. `chronyd` will not create the socket if the directory has a wrong owner or permissions. In this case there should be an error message from `chronyd` in the system log. === What is the reference ID reported by the `tracking` command? The reference ID is a 32-bit value used in NTP to prevent synchronisation loops. In `chrony` versions before 3.0 it was printed in the quad-dotted notation, even if the reference source did not actually have an IPv4 address. For IPv4 addresses, the reference ID is equal to the address, but for IPv6 addresses it is the first 32 bits of the MD5 sum of the address. For reference clocks, the reference ID is the value specified with the `refid` option in the `refclock` directive. Since version 3.0, the reference ID is printed as a hexadecimal number to avoid confusion with IPv4 addresses. If you need to get the IP address of the current reference source, use the `-n` option to disable resolving of IP addresses and read the second field (printed in parentheses) on the `Reference ID` line. === Is the `chronyc` / `chronyd` protocol documented anywhere? Only by the source code. See _cmdmon.c_ (`chronyd` side) and _client.c_ (`chronyc` side). == Real-time clock issues === What is the real-time clock (RTC)? This is the clock which keeps the time even when your computer is turned off. It is used to initialise the system clock on boot. It normally does not drift more than few seconds per day. There are two approaches how `chronyd` can work with it. One is to use the `rtcsync` directive, which tells `chronyd` to enable a kernel mode which sets the RTC from the system clock every 11 minutes. `chronyd` itself won't touch the RTC. If the computer is not turned off for a long time, the RTC should still be close to the true time when the system clock will be initialised from it on the next boot. The other option is to use the `rtcfile` directive, which tells `chronyd` to monitor the rate at which the RTC gains or loses time. When `chronyd` is started with the `-s` option on the next boot, it will set the system time from the RTC and also compensate for the drift it has measured previously. The `rtcautotrim` directive can be used to keep the RTC close to the true time, but it is not strictly necessary if its only purpose is to set the system clock when `chronyd` is started on boot. See the documentation for details. === Does `hwclock` have to be disabled? The `hwclock` program is often set-up by default in the boot and shutdown scripts with many Linux installations. With the kernel RTC synchronisation (`rtcsync` directive), the RTC will be set also every 11 minutes as long as the system clock is synchronised. If you want to use ``chronyd``'s RTC monitoring (`rtcfile` directive), it is important to disable `hwclock` in the shutdown procedure. If you do not that, it will over-write the RTC with a new value, unknown to `chronyd`. At the next reboot, `chronyd` started with the `-s` option will compensate this (wrong) time with its estimate of how far the RTC has drifted whilst the power was off, giving a meaningless initial system time. There is no need to remove `hwclock` from the boot process, as long as `chronyd` is started after it has run. === I just keep getting the `513 RTC driver not running` message For the real-time clock support to work, you need the following three things * an RTC in your computer * a Linux kernel with enabled RTC support * an `rtcfile` directive in your _chrony.conf_ file === I get `Could not open /dev/rtc, Device or resource busy` in my syslog file Some other program running on the system might be using the device. === What if my computer does not have an RTC or backup battery? In this case you can still use the `-s` option to set the system clock to the last modification time of the drift file, which should correspond to the system time when `chronyd` was previously stopped. The initial system time will be increasing across reboots and applications started after `chronyd` will not observe backward steps. == NTP-specific issues === Can `chronyd` be driven from broadcast/multicast NTP servers? No, the broadcast/multicast client mode is not supported and there is currently no plan to implement it. While this mode can simplify configuration of clients in large networks, it is inherently less accurate and less secure (even with authentication) than the ordinary client/server mode. When configuring a large number of clients in a network, it is recommended to use the `pool` directive with a DNS name which resolves to addresses of multiple NTP servers. The clients will automatically replace the servers when they become unreachable, or otherwise unsuitable for synchronisation, with new servers from the pool. Even with very modest hardware, an NTP server can serve time to hundreds of thousands of clients using the ordinary client/server mode. === Can `chronyd` transmit broadcast NTP packets? Yes, the `broadcast` directive can be used to enable the broadcast server mode to serve time to clients in the network which support the broadcast client mode (it is not supported in `chronyd`). Note that this mode should generally be avoided. See the previous question. === Can `chronyd` keep the system clock a fixed offset away from real time? Yes. Starting from version 3.0, an offset can be specified by the `offset` option for all time sources in the _chrony.conf_ file. === What happens if the network connection is dropped without using ``chronyc``'s `offline` command first? `chronyd` will keep trying to access the sources that it thinks are online, and it will take longer before new measurements are actually made and the clock is corrected when the network is connected again. If the sources were set to offline, `chronyd` would make new measurements immediately after issuing the `online` command. Unless the network connection lasts only few minutes (less than the maximum polling interval), the delay is usually not a problem, and it might be acceptable to keep all sources online all the time. === Why is an offset measured between two computers synchronised to each another? When two computers are synchronised to each other using the client/server or symmetric NTP mode, there is an expectation that NTP measurements between the two computers made on both ends show an average offset close to zero. With `chronyd` that can be expected only when the interleaved mode (`xleave` option) is enabled. Otherwise, `chronyd` will use different transmit timestamps (e.g. daemon timestamp vs kernel timestamp) for serving time and synchronisation of its own clock, which creates an asymmetry in the timestamping and causes the other end to measure a significant offset. == Operating systems === Does `chrony` support Windows? No. The `chronyc` program (the command-line client used for configuring `chronyd` while it is running) has been successfully built and run under Cygwin in the past. `chronyd` is not portable, because part of it is very system-dependent. It needs adapting to work with Windows' equivalent of the adjtimex() call, and it needs to be made to work as a service. === Are there any plans to support Windows? We have no plans to do this. Anyone is welcome to pick this work up and contribute it back to the project.