summaryrefslogtreecommitdiffstats
path: root/Documentation/devicetree/bindings/iio/health
diff options
context:
space:
mode:
authorDaniel Baumann <daniel.baumann@progress-linux.org>2024-05-06 01:02:30 +0000
committerDaniel Baumann <daniel.baumann@progress-linux.org>2024-05-06 01:02:30 +0000
commit76cb841cb886eef6b3bee341a2266c76578724ad (patch)
treef5892e5ba6cc11949952a6ce4ecbe6d516d6ce58 /Documentation/devicetree/bindings/iio/health
parentInitial commit. (diff)
downloadlinux-upstream/4.19.249.tar.xz
linux-upstream/4.19.249.zip
Adding upstream version 4.19.249.upstream/4.19.249upstream
Signed-off-by: Daniel Baumann <daniel.baumann@progress-linux.org>
Diffstat (limited to 'Documentation/devicetree/bindings/iio/health')
-rw-r--r--Documentation/devicetree/bindings/iio/health/afe4403.txt33
-rw-r--r--Documentation/devicetree/bindings/iio/health/afe4404.txt29
-rw-r--r--Documentation/devicetree/bindings/iio/health/max30100.txt28
-rw-r--r--Documentation/devicetree/bindings/iio/health/max30102.txt33
4 files changed, 123 insertions, 0 deletions
diff --git a/Documentation/devicetree/bindings/iio/health/afe4403.txt b/Documentation/devicetree/bindings/iio/health/afe4403.txt
new file mode 100644
index 000000000..8e412054d
--- /dev/null
+++ b/Documentation/devicetree/bindings/iio/health/afe4403.txt
@@ -0,0 +1,33 @@
+Texas Instruments AFE4403 Heart rate and Pulse Oximeter
+
+Required properties:
+ - compatible : Should be "ti,afe4403".
+ - reg : SPI chip select address of device.
+ - tx-supply : Regulator supply to transmitting LEDs.
+ - interrupts : The interrupt line the device ADC_RDY pin is
+ connected to. For details refer to,
+ ../../interrupt-controller/interrupts.txt.
+
+Optional properties:
+ - reset-gpios : GPIO used to reset the device.
+ For details refer to, ../../gpio/gpio.txt.
+
+For other required and optional properties of SPI slave nodes
+please refer to ../../spi/spi-bus.txt.
+
+Example:
+
+&spi0 {
+ heart_mon@0 {
+ compatible = "ti,afe4403";
+ reg = <0>;
+ spi-max-frequency = <10000000>;
+
+ tx-supply = <&vbat>;
+
+ interrupt-parent = <&gpio1>;
+ interrupts = <28 IRQ_TYPE_EDGE_RISING>;
+
+ reset-gpios = <&gpio1 16 GPIO_ACTIVE_LOW>;
+ };
+};
diff --git a/Documentation/devicetree/bindings/iio/health/afe4404.txt b/Documentation/devicetree/bindings/iio/health/afe4404.txt
new file mode 100644
index 000000000..0b52830a0
--- /dev/null
+++ b/Documentation/devicetree/bindings/iio/health/afe4404.txt
@@ -0,0 +1,29 @@
+Texas Instruments AFE4404 Heart rate and Pulse Oximeter
+
+Required properties:
+ - compatible : Should be "ti,afe4404".
+ - reg : I2C address of the device.
+ - tx-supply : Regulator supply to transmitting LEDs.
+ - interrupts : The interrupt line the device ADC_RDY pin is
+ connected to. For details refer to,
+ ../interrupt-controller/interrupts.txt.
+
+Optional properties:
+ - reset-gpios : GPIO used to reset the device.
+ For details refer to, ../gpio/gpio.txt.
+
+Example:
+
+&i2c2 {
+ heart_mon@58 {
+ compatible = "ti,afe4404";
+ reg = <0x58>;
+
+ tx-supply = <&vbat>;
+
+ interrupt-parent = <&gpio1>;
+ interrupts = <28 IRQ_TYPE_EDGE_RISING>;
+
+ reset-gpios = <&gpio1 16 GPIO_ACTIVE_LOW>;
+ };
+};
diff --git a/Documentation/devicetree/bindings/iio/health/max30100.txt b/Documentation/devicetree/bindings/iio/health/max30100.txt
new file mode 100644
index 000000000..0054908a6
--- /dev/null
+++ b/Documentation/devicetree/bindings/iio/health/max30100.txt
@@ -0,0 +1,28 @@
+Maxim MAX30100 heart rate and pulse oximeter sensor
+
+* https://datasheets.maximintegrated.com/en/ds/MAX30100.pdf
+
+Required properties:
+ - compatible: must be "maxim,max30100"
+ - reg: the I2C address of the sensor
+ - interrupts: the sole interrupt generated by the device
+
+ Refer to interrupt-controller/interrupts.txt for generic
+ interrupt client node bindings.
+
+Optional properties:
+ - maxim,led-current-microamp: configuration for LED current in microamperes
+ while the engine is running. First indexed value is the configuration for
+ the RED LED, and second value is for the IR LED.
+
+ Refer to the datasheet for the allowed current values.
+
+Example:
+
+max30100@57 {
+ compatible = "maxim,max30100";
+ reg = <0x57>;
+ maxim,led-current-microamp = <24000 50000>;
+ interrupt-parent = <&gpio1>;
+ interrupts = <16 2>;
+};
diff --git a/Documentation/devicetree/bindings/iio/health/max30102.txt b/Documentation/devicetree/bindings/iio/health/max30102.txt
new file mode 100644
index 000000000..7ef7ae40a
--- /dev/null
+++ b/Documentation/devicetree/bindings/iio/health/max30102.txt
@@ -0,0 +1,33 @@
+Maxim MAX30102 heart rate and pulse oximeter sensor
+Maxim MAX30105 optical particle-sensing module
+
+* https://datasheets.maximintegrated.com/en/ds/MAX30102.pdf
+* https://datasheets.maximintegrated.com/en/ds/MAX30105.pdf
+
+Required properties:
+ - compatible: must be "maxim,max30102" or "maxim,max30105"
+ - reg: the I2C address of the sensor
+ - interrupts: the sole interrupt generated by the device
+
+ Refer to interrupt-controller/interrupts.txt for generic
+ interrupt client node bindings.
+
+Optional properties:
+ - maxim,red-led-current-microamp: configuration for red LED current
+ - maxim,ir-led-current-microamp: configuration for IR LED current
+ - maxim,green-led-current-microamp: configuration for green LED current
+ (max30105 only)
+
+ Note that each step is approximately 200 microamps, ranging from 0 uA to
+ 50800 uA.
+
+Example:
+
+max30102@57 {
+ compatible = "maxim,max30102";
+ reg = <0x57>;
+ maxim,red-led-current-microamp = <7000>;
+ maxim,ir-led-current-microamp = <7000>;
+ interrupt-parent = <&gpio1>;
+ interrupts = <16 2>;
+};