summaryrefslogtreecommitdiffstats
path: root/Documentation/hwmon/max6639
diff options
context:
space:
mode:
authorDaniel Baumann <daniel.baumann@progress-linux.org>2024-05-06 01:02:30 +0000
committerDaniel Baumann <daniel.baumann@progress-linux.org>2024-05-06 01:02:30 +0000
commit76cb841cb886eef6b3bee341a2266c76578724ad (patch)
treef5892e5ba6cc11949952a6ce4ecbe6d516d6ce58 /Documentation/hwmon/max6639
parentInitial commit. (diff)
downloadlinux-upstream/4.19.249.tar.xz
linux-upstream/4.19.249.zip
Adding upstream version 4.19.249.upstream/4.19.249upstream
Signed-off-by: Daniel Baumann <daniel.baumann@progress-linux.org>
Diffstat (limited to 'Documentation/hwmon/max6639')
-rw-r--r--Documentation/hwmon/max663949
1 files changed, 49 insertions, 0 deletions
diff --git a/Documentation/hwmon/max6639 b/Documentation/hwmon/max6639
new file mode 100644
index 000000000..dc49f8be7
--- /dev/null
+++ b/Documentation/hwmon/max6639
@@ -0,0 +1,49 @@
+Kernel driver max6639
+=====================
+
+Supported chips:
+ * Maxim MAX6639
+ Prefix: 'max6639'
+ Addresses scanned: I2C 0x2c, 0x2e, 0x2f
+ Datasheet: http://pdfserv.maxim-ic.com/en/ds/MAX6639.pdf
+
+Authors:
+ He Changqing <hechangqing@semptian.com>
+ Roland Stigge <stigge@antcom.de>
+
+Description
+-----------
+
+This driver implements support for the Maxim MAX6639. This chip is a 2-channel
+temperature monitor with dual PWM fan speed controller. It can monitor its own
+temperature and one external diode-connected transistor or two external
+diode-connected transistors.
+
+The following device attributes are implemented via sysfs:
+
+Attribute R/W Contents
+----------------------------------------------------------------------------
+temp1_input R Temperature channel 1 input (0..150 C)
+temp2_input R Temperature channel 2 input (0..150 C)
+temp1_fault R Temperature channel 1 diode fault
+temp2_fault R Temperature channel 2 diode fault
+temp1_max RW Set THERM temperature for input 1
+ (in C, see datasheet)
+temp2_max RW Set THERM temperature for input 2
+temp1_crit RW Set ALERT temperature for input 1
+temp2_crit RW Set ALERT temperature for input 2
+temp1_emergency RW Set OT temperature for input 1
+ (in C, see datasheet)
+temp2_emergency RW Set OT temperature for input 2
+pwm1 RW Fan 1 target duty cycle (0..255)
+pwm2 RW Fan 2 target duty cycle (0..255)
+fan1_input R TACH1 fan tachometer input (in RPM)
+fan2_input R TACH2 fan tachometer input (in RPM)
+fan1_fault R Fan 1 fault
+fan2_fault R Fan 2 fault
+temp1_max_alarm R Alarm on THERM temperature on channel 1
+temp2_max_alarm R Alarm on THERM temperature on channel 2
+temp1_crit_alarm R Alarm on ALERT temperature on channel 1
+temp2_crit_alarm R Alarm on ALERT temperature on channel 2
+temp1_emergency_alarm R Alarm on OT temperature on channel 1
+temp2_emergency_alarm R Alarm on OT temperature on channel 2