summaryrefslogtreecommitdiffstats
path: root/Documentation/hwmon/powr1220
diff options
context:
space:
mode:
authorDaniel Baumann <daniel.baumann@progress-linux.org>2024-05-06 01:02:30 +0000
committerDaniel Baumann <daniel.baumann@progress-linux.org>2024-05-06 01:02:30 +0000
commit76cb841cb886eef6b3bee341a2266c76578724ad (patch)
treef5892e5ba6cc11949952a6ce4ecbe6d516d6ce58 /Documentation/hwmon/powr1220
parentInitial commit. (diff)
downloadlinux-76cb841cb886eef6b3bee341a2266c76578724ad.tar.xz
linux-76cb841cb886eef6b3bee341a2266c76578724ad.zip
Adding upstream version 4.19.249.upstream/4.19.249upstream
Signed-off-by: Daniel Baumann <daniel.baumann@progress-linux.org>
Diffstat (limited to 'Documentation/hwmon/powr1220')
-rw-r--r--Documentation/hwmon/powr122045
1 files changed, 45 insertions, 0 deletions
diff --git a/Documentation/hwmon/powr1220 b/Documentation/hwmon/powr1220
new file mode 100644
index 000000000..21e44f71a
--- /dev/null
+++ b/Documentation/hwmon/powr1220
@@ -0,0 +1,45 @@
+Kernel driver powr1220
+==================
+
+Supported chips:
+ * Lattice POWR1220AT8
+ Prefix: 'powr1220'
+ Addresses scanned: none
+ Datasheet: Publicly available at the Lattice website
+ http://www.latticesemi.com/
+
+Author: Scott Kanowitz <scott.kanowitz@gmail.com>
+
+Description
+-----------
+
+This driver supports the Lattice POWR1220AT8 chip. The POWR1220
+includes voltage monitoring for 14 inputs as well as trim settings
+for output voltages and GPIOs. This driver implements the voltage
+monitoring portion of the chip.
+
+Voltages are sampled by a 12-bit ADC with a step size of 2 mV.
+An in-line attenuator allows measurements from 0 to 6 V. The
+attenuator is enabled or disabled depending on the setting of the
+input's max value. The driver will enable the attenuator for any
+value over the low measurement range maximum of 2 V.
+
+The input naming convention is as follows:
+
+driver name pin name
+in0 VMON1
+in1 VMON2
+in2 VMON3
+in2 VMON4
+in4 VMON5
+in5 VMON6
+in6 VMON7
+in7 VMON8
+in8 VMON9
+in9 VMON10
+in10 VMON11
+in11 VMON12
+in12 VCCA
+in13 VCCINP
+
+The ADC readings are updated on request with a minimum period of 1s.