summaryrefslogtreecommitdiffstats
path: root/drivers/iio/health/Kconfig
diff options
context:
space:
mode:
authorDaniel Baumann <daniel.baumann@progress-linux.org>2024-05-06 01:02:30 +0000
committerDaniel Baumann <daniel.baumann@progress-linux.org>2024-05-06 01:02:30 +0000
commit76cb841cb886eef6b3bee341a2266c76578724ad (patch)
treef5892e5ba6cc11949952a6ce4ecbe6d516d6ce58 /drivers/iio/health/Kconfig
parentInitial commit. (diff)
downloadlinux-76cb841cb886eef6b3bee341a2266c76578724ad.tar.xz
linux-76cb841cb886eef6b3bee341a2266c76578724ad.zip
Adding upstream version 4.19.249.upstream/4.19.249upstream
Signed-off-by: Daniel Baumann <daniel.baumann@progress-linux.org>
Diffstat (limited to 'drivers/iio/health/Kconfig')
-rw-r--r--drivers/iio/health/Kconfig64
1 files changed, 64 insertions, 0 deletions
diff --git a/drivers/iio/health/Kconfig b/drivers/iio/health/Kconfig
new file mode 100644
index 000000000..a2ecb4c94
--- /dev/null
+++ b/drivers/iio/health/Kconfig
@@ -0,0 +1,64 @@
+#
+# Health sensors
+#
+# When adding new entries keep the list in alphabetical order
+
+menu "Health Sensors"
+
+menu "Heart Rate Monitors"
+
+config AFE4403
+ tristate "TI AFE4403 Heart Rate Monitor"
+ depends on SPI_MASTER
+ select REGMAP_SPI
+ select IIO_BUFFER
+ select IIO_TRIGGERED_BUFFER
+ help
+ Say yes to choose the Texas Instruments AFE4403
+ heart rate monitor and low-cost pulse oximeter.
+
+ To compile this driver as a module, choose M here: the
+ module will be called afe4403.
+
+config AFE4404
+ tristate "TI AFE4404 heart rate and pulse oximeter sensor"
+ depends on I2C
+ select REGMAP_I2C
+ select IIO_BUFFER
+ select IIO_TRIGGERED_BUFFER
+ help
+ Say yes to choose the Texas Instruments AFE4404
+ heart rate monitor and low-cost pulse oximeter.
+
+ To compile this driver as a module, choose M here: the
+ module will be called afe4404.
+
+config MAX30100
+ tristate "MAX30100 heart rate and pulse oximeter sensor"
+ depends on I2C
+ select REGMAP_I2C
+ select IIO_BUFFER
+ select IIO_KFIFO_BUF
+ help
+ Say Y here to build I2C interface support for the Maxim
+ MAX30100 heart rate, and pulse oximeter sensor.
+
+ To compile this driver as a module, choose M here: the
+ module will be called max30100.
+
+config MAX30102
+ tristate "MAX30102 heart rate and pulse oximeter sensor"
+ depends on I2C
+ select REGMAP_I2C
+ select IIO_BUFFER
+ select IIO_KFIFO_BUF
+ help
+ Say Y here to build I2C interface support for the Maxim
+ MAX30102 heart rate, and pulse oximeter sensor.
+
+ To compile this driver as a module, choose M here: the
+ module will be called max30102.
+
+endmenu
+
+endmenu