summaryrefslogtreecommitdiffstats
path: root/drivers/iio/temperature/Kconfig
diff options
context:
space:
mode:
Diffstat (limited to '')
-rw-r--r--drivers/iio/temperature/Kconfig100
1 files changed, 100 insertions, 0 deletions
diff --git a/drivers/iio/temperature/Kconfig b/drivers/iio/temperature/Kconfig
new file mode 100644
index 000000000..82e4a6274
--- /dev/null
+++ b/drivers/iio/temperature/Kconfig
@@ -0,0 +1,100 @@
+#
+# Temperature sensor drivers
+#
+menu "Temperature sensors"
+
+config MAXIM_THERMOCOUPLE
+ tristate "Maxim thermocouple sensors"
+ depends on SPI
+ select IIO_BUFFER
+ select IIO_TRIGGERED_BUFFER
+ help
+ If you say yes here you get support for the Maxim series of
+ thermocouple sensors connected via SPI.
+
+ Supported sensors:
+ * MAX6675
+ * MAX31855
+
+ This driver can also be built as a module. If so, the module will
+ be called maxim_thermocouple.
+
+config HID_SENSOR_TEMP
+ tristate "HID Environmental temperature sensor"
+ depends on HID_SENSOR_HUB
+ select IIO_BUFFER
+ select IIO_TRIGGERED_BUFFER
+ select HID_SENSOR_IIO_COMMON
+ select HID_SENSOR_IIO_TRIGGER
+ help
+ Say yes here to build support for the HID SENSOR
+ temperature driver
+
+ To compile this driver as a module, choose M here: the module
+ will be called hid-sensor-temperature.
+
+config MLX90614
+ tristate "MLX90614 contact-less infrared sensor"
+ depends on I2C
+ help
+ If you say yes here you get support for the Melexis
+ MLX90614 contact-less infrared sensor connected with I2C.
+
+ This driver can also be built as a module. If so, the module will
+ be called mlx90614.
+
+config MLX90632
+ tristate "MLX90632 contact-less infrared sensor with medical accuracy"
+ depends on I2C
+ select REGMAP_I2C
+ help
+ If you say yes here you get support for the Melexis
+ MLX90632 contact-less infrared sensor with medical accuracy
+ connected with I2C.
+
+ This driver can also be built as a module. If so, the module will
+ be called mlx90632.
+
+config TMP006
+ tristate "TMP006 infrared thermopile sensor"
+ depends on I2C
+ help
+ If you say yes here you get support for the Texas Instruments
+ TMP006 infrared thermopile sensor.
+
+ This driver can also be built as a module. If so, the module will
+ be called tmp006.
+
+config TMP007
+ tristate "TMP007 infrared thermopile sensor with Integrated Math Engine"
+ depends on I2C
+ help
+ If you say yes here you get support for the Texas Instruments
+ TMP007 infrared thermopile sensor with Integrated Math Engine.
+
+ This driver can also be built as a module. If so, the module will
+ be called tmp007.
+
+config TSYS01
+ tristate "Measurement Specialties TSYS01 temperature sensor using I2C bus connection"
+ depends on I2C
+ select IIO_MS_SENSORS_I2C
+ help
+ If you say yes here you get support for the Measurement Specialties
+ TSYS01 I2C temperature sensor.
+
+ This driver can also be built as a module. If so, the module will
+ be called tsys01.
+
+config TSYS02D
+ tristate "Measurement Specialties TSYS02D temperature sensor"
+ depends on I2C
+ select IIO_MS_SENSORS_I2C
+ help
+ If you say yes here you get support for the Measurement Specialties
+ TSYS02D temperature sensor.
+
+ This driver can also be built as a module. If so, the module will
+ be called tsys02d.
+
+endmenu