diff options
Diffstat (limited to 'tools/perf/pmu-events/arch/powerpc/power8/pipeline.json')
-rw-r--r-- | tools/perf/pmu-events/arch/powerpc/power8/pipeline.json | 350 |
1 files changed, 350 insertions, 0 deletions
diff --git a/tools/perf/pmu-events/arch/powerpc/power8/pipeline.json b/tools/perf/pmu-events/arch/powerpc/power8/pipeline.json new file mode 100644 index 000000000..293f3a4c6 --- /dev/null +++ b/tools/perf/pmu-events/arch/powerpc/power8/pipeline.json @@ -0,0 +1,350 @@ +[ + {, + "EventCode": "0x100f2", + "EventName": "PM_1PLUS_PPC_CMPL", + "BriefDescription": "1 or more ppc insts finished", + "PublicDescription": "1 or more ppc insts finished (completed)" + }, + {, + "EventCode": "0x400f2", + "EventName": "PM_1PLUS_PPC_DISP", + "BriefDescription": "Cycles at least one Instr Dispatched", + "PublicDescription": "Cycles at least one Instr Dispatched. Could be a group with only microcode. Issue HW016521" + }, + {, + "EventCode": "0x100fa", + "EventName": "PM_ANY_THRD_RUN_CYC", + "BriefDescription": "One of threads in run_cycles", + "PublicDescription": "Any thread in run_cycles (was one thread in run_cycles)" + }, + {, + "EventCode": "0x4000a", + "EventName": "PM_CMPLU_STALL", + "BriefDescription": "Completion stall", + "PublicDescription": "" + }, + {, + "EventCode": "0x4d018", + "EventName": "PM_CMPLU_STALL_BRU", + "BriefDescription": "Completion stall due to a Branch Unit", + "PublicDescription": "" + }, + {, + "EventCode": "0x2c012", + "EventName": "PM_CMPLU_STALL_DCACHE_MISS", + "BriefDescription": "Completion stall by Dcache miss", + "PublicDescription": "" + }, + {, + "EventCode": "0x2c018", + "EventName": "PM_CMPLU_STALL_DMISS_L21_L31", + "BriefDescription": "Completion stall by Dcache miss which resolved on chip ( excluding local L2/L3)", + "PublicDescription": "" + }, + {, + "EventCode": "0x2c016", + "EventName": "PM_CMPLU_STALL_DMISS_L2L3", + "BriefDescription": "Completion stall by Dcache miss which resolved in L2/L3", + "PublicDescription": "" + }, + {, + "EventCode": "0x4c016", + "EventName": "PM_CMPLU_STALL_DMISS_L2L3_CONFLICT", + "BriefDescription": "Completion stall due to cache miss that resolves in the L2 or L3 with a conflict", + "PublicDescription": "Completion stall due to cache miss resolving in core's L2/L3 with a conflict" + }, + {, + "EventCode": "0x4c01a", + "EventName": "PM_CMPLU_STALL_DMISS_L3MISS", + "BriefDescription": "Completion stall due to cache miss resolving missed the L3", + "PublicDescription": "" + }, + {, + "EventCode": "0x4c018", + "EventName": "PM_CMPLU_STALL_DMISS_LMEM", + "BriefDescription": "Completion stall due to cache miss that resolves in local memory", + "PublicDescription": "Completion stall due to cache miss resolving in core's Local Memory" + }, + {, + "EventCode": "0x2c01c", + "EventName": "PM_CMPLU_STALL_DMISS_REMOTE", + "BriefDescription": "Completion stall by Dcache miss which resolved from remote chip (cache or memory)", + "PublicDescription": "Completion stall by Dcache miss which resolved on chip ( excluding local L2/L3)" + }, + {, + "EventCode": "0x4c012", + "EventName": "PM_CMPLU_STALL_ERAT_MISS", + "BriefDescription": "Completion stall due to LSU reject ERAT miss", + "PublicDescription": "" + }, + {, + "EventCode": "0x4d016", + "EventName": "PM_CMPLU_STALL_FXLONG", + "BriefDescription": "Completion stall due to a long latency fixed point instruction", + "PublicDescription": "" + }, + {, + "EventCode": "0x2d016", + "EventName": "PM_CMPLU_STALL_FXU", + "BriefDescription": "Completion stall due to FXU", + "PublicDescription": "" + }, + {, + "EventCode": "0x30036", + "EventName": "PM_CMPLU_STALL_HWSYNC", + "BriefDescription": "completion stall due to hwsync", + "PublicDescription": "" + }, + {, + "EventCode": "0x4d014", + "EventName": "PM_CMPLU_STALL_LOAD_FINISH", + "BriefDescription": "Completion stall due to a Load finish", + "PublicDescription": "" + }, + {, + "EventCode": "0x2c010", + "EventName": "PM_CMPLU_STALL_LSU", + "BriefDescription": "Completion stall by LSU instruction", + "PublicDescription": "" + }, + {, + "EventCode": "0x10036", + "EventName": "PM_CMPLU_STALL_LWSYNC", + "BriefDescription": "completion stall due to isync/lwsync", + "PublicDescription": "" + }, + {, + "EventCode": "0x30006", + "EventName": "PM_CMPLU_STALL_OTHER_CMPL", + "BriefDescription": "Instructions core completed while this tread was stalled", + "PublicDescription": "Instructions core completed while this thread was stalled" + }, + {, + "EventCode": "0x4c01c", + "EventName": "PM_CMPLU_STALL_ST_FWD", + "BriefDescription": "Completion stall due to store forward", + "PublicDescription": "" + }, + {, + "EventCode": "0x1001c", + "EventName": "PM_CMPLU_STALL_THRD", + "BriefDescription": "Completion Stalled due to thread conflict. Group ready to complete but it was another thread's turn", + "PublicDescription": "Completion stall due to thread conflict" + }, + {, + "EventCode": "0x1e", + "EventName": "PM_CYC", + "BriefDescription": "Cycles", + "PublicDescription": "" + }, + {, + "EventCode": "0x10006", + "EventName": "PM_DISP_HELD", + "BriefDescription": "Dispatch Held", + "PublicDescription": "" + }, + {, + "EventCode": "0x4003c", + "EventName": "PM_DISP_HELD_SYNC_HOLD", + "BriefDescription": "Dispatch held due to SYNC hold", + "PublicDescription": "" + }, + {, + "EventCode": "0x200f8", + "EventName": "PM_EXT_INT", + "BriefDescription": "external interrupt", + "PublicDescription": "" + }, + {, + "EventCode": "0x400f8", + "EventName": "PM_FLUSH", + "BriefDescription": "Flush (any type)", + "PublicDescription": "" + }, + {, + "EventCode": "0x30012", + "EventName": "PM_FLUSH_COMPLETION", + "BriefDescription": "Completion Flush", + "PublicDescription": "" + }, + {, + "EventCode": "0x3000c", + "EventName": "PM_FREQ_DOWN", + "BriefDescription": "Power Management: Below Threshold B", + "PublicDescription": "Frequency is being slewed down due to Power Management" + }, + {, + "EventCode": "0x4000c", + "EventName": "PM_FREQ_UP", + "BriefDescription": "Power Management: Above Threshold A", + "PublicDescription": "Frequency is being slewed up due to Power Management" + }, + {, + "EventCode": "0x2000a", + "EventName": "PM_HV_CYC", + "BriefDescription": "Cycles in which msr_hv is high. Note that this event does not take msr_pr into consideration", + "PublicDescription": "cycles in hypervisor mode" + }, + {, + "EventCode": "0x3405e", + "EventName": "PM_IFETCH_THROTTLE", + "BriefDescription": "Cycles in which Instruction fetch throttle was active", + "PublicDescription": "Cycles instruction fecth was throttled in IFU" + }, + {, + "EventCode": "0x10014", + "EventName": "PM_IOPS_CMPL", + "BriefDescription": "Internal Operations completed", + "PublicDescription": "IOPS Completed" + }, + {, + "EventCode": "0x3c058", + "EventName": "PM_LARX_FIN", + "BriefDescription": "Larx finished", + "PublicDescription": "" + }, + {, + "EventCode": "0x1002e", + "EventName": "PM_LD_CMPL", + "BriefDescription": "count of Loads completed", + "PublicDescription": "" + }, + {, + "EventCode": "0x10062", + "EventName": "PM_LD_L3MISS_PEND_CYC", + "BriefDescription": "Cycles L3 miss was pending for this thread", + "PublicDescription": "" + }, + {, + "EventCode": "0x30066", + "EventName": "PM_LSU_FIN", + "BriefDescription": "LSU Finished an instruction (up to 2 per cycle)", + "PublicDescription": "" + }, + {, + "EventCode": "0x2003e", + "EventName": "PM_LSU_LMQ_SRQ_EMPTY_CYC", + "BriefDescription": "LSU empty (lmq and srq empty)", + "PublicDescription": "" + }, + {, + "EventCode": "0x2e05c", + "EventName": "PM_LSU_REJECT_ERAT_MISS", + "BriefDescription": "LSU Reject due to ERAT (up to 4 per cycles)", + "PublicDescription": "" + }, + {, + "EventCode": "0x4e05c", + "EventName": "PM_LSU_REJECT_LHS", + "BriefDescription": "LSU Reject due to LHS (up to 4 per cycle)", + "PublicDescription": "" + }, + {, + "EventCode": "0x1e05c", + "EventName": "PM_LSU_REJECT_LMQ_FULL", + "BriefDescription": "LSU reject due to LMQ full ( 4 per cycle)", + "PublicDescription": "" + }, + {, + "EventCode": "0x1001a", + "EventName": "PM_LSU_SRQ_FULL_CYC", + "BriefDescription": "Storage Queue is full and is blocking dispatch", + "PublicDescription": "SRQ is Full" + }, + {, + "EventCode": "0x40014", + "EventName": "PM_PROBE_NOP_DISP", + "BriefDescription": "ProbeNops dispatched", + "PublicDescription": "" + }, + {, + "EventCode": "0x600f4", + "EventName": "PM_RUN_CYC", + "BriefDescription": "Run_cycles", + "PublicDescription": "" + }, + {, + "EventCode": "0x3006c", + "EventName": "PM_RUN_CYC_SMT2_MODE", + "BriefDescription": "Cycles run latch is set and core is in SMT2 mode", + "PublicDescription": "" + }, + {, + "EventCode": "0x2006c", + "EventName": "PM_RUN_CYC_SMT4_MODE", + "BriefDescription": "cycles this threads run latch is set and the core is in SMT4 mode", + "PublicDescription": "Cycles run latch is set and core is in SMT4 mode" + }, + {, + "EventCode": "0x1006c", + "EventName": "PM_RUN_CYC_ST_MODE", + "BriefDescription": "Cycles run latch is set and core is in ST mode", + "PublicDescription": "" + }, + {, + "EventCode": "0x500fa", + "EventName": "PM_RUN_INST_CMPL", + "BriefDescription": "Run_Instructions", + "PublicDescription": "" + }, + {, + "EventCode": "0x1e058", + "EventName": "PM_STCX_FAIL", + "BriefDescription": "stcx failed", + "PublicDescription": "" + }, + {, + "EventCode": "0x20016", + "EventName": "PM_ST_CMPL", + "BriefDescription": "Store completion count", + "PublicDescription": "" + }, + {, + "EventCode": "0x200f0", + "EventName": "PM_ST_FIN", + "BriefDescription": "Store Instructions Finished", + "PublicDescription": "Store Instructions Finished (store sent to nest)" + }, + {, + "EventCode": "0x20018", + "EventName": "PM_ST_FWD", + "BriefDescription": "Store forwards that finished", + "PublicDescription": "" + }, + {, + "EventCode": "0x10026", + "EventName": "PM_TABLEWALK_CYC", + "BriefDescription": "Cycles when a tablewalk (I or D) is active", + "PublicDescription": "Tablewalk Active" + }, + {, + "EventCode": "0x300f8", + "EventName": "PM_TB_BIT_TRANS", + "BriefDescription": "timebase event", + "PublicDescription": "" + }, + {, + "EventCode": "0x2000c", + "EventName": "PM_THRD_ALL_RUN_CYC", + "BriefDescription": "All Threads in Run_cycles (was both threads in run_cycles)", + "PublicDescription": "" + }, + {, + "EventCode": "0x30058", + "EventName": "PM_TLBIE_FIN", + "BriefDescription": "tlbie finished", + "PublicDescription": "" + }, + {, + "EventCode": "0x10060", + "EventName": "PM_TM_TRANS_RUN_CYC", + "BriefDescription": "run cycles in transactional state", + "PublicDescription": "" + }, + {, + "EventCode": "0x2e012", + "EventName": "PM_TM_TX_PASS_RUN_CYC", + "BriefDescription": "cycles spent in successful transactions", + "PublicDescription": "run cycles spent in successful transactions" + }, +] |