diff options
Diffstat (limited to '')
-rw-r--r-- | doc/man/nvme_st_result.2 | 77 |
1 files changed, 77 insertions, 0 deletions
diff --git a/doc/man/nvme_st_result.2 b/doc/man/nvme_st_result.2 new file mode 100644 index 0000000..bd52e2d --- /dev/null +++ b/doc/man/nvme_st_result.2 @@ -0,0 +1,77 @@ +.TH "libnvme" 9 "struct nvme_st_result" "January 2023" "API Manual" LINUX +.SH NAME +struct nvme_st_result \- Self-test Result +.SH SYNOPSIS +struct nvme_st_result { +.br +.BI " __u8 dsts;" +.br +.BI " __u8 seg;" +.br +.BI " __u8 vdi;" +.br +.BI " __u8 rsvd;" +.br +.BI " __le64 poh;" +.br +.BI " __le32 nsid;" +.br +.BI " __le64 flba;" +.br +.BI " __u8 sct;" +.br +.BI " __u8 sc;" +.br +.BI " __u8 vs[2];" +.br +.BI " +}; +.br + +.SH Members +.IP "dsts" 12 +Device Self-test Status: Indicates the device self-test code and the +status of the operation (see \fIenum nvme_status_result\fP and \fIenum nvme_st_code\fP). +.IP "seg" 12 +Segment Number: Iindicates the segment number where the first self-test +failure occurred. If Device Self-test Status (\fIdsts\fP) is not set to +#NVME_ST_RESULT_KNOWN_SEG_FAIL, then this field should be ignored. +.IP "vdi" 12 +Valid Diagnostic Information: Indicates the diagnostic failure +information that is reported. See \fIenum nvme_st_valid_diag_info\fP. +.IP "rsvd" 12 +Reserved +.IP "poh" 12 +Power On Hours (POH): Indicates the number of power-on hours at the +time the device self-test operation was completed or aborted. This +does not include time that the controller was powered and in a low +power state condition. +.IP "nsid" 12 +Namespace Identifier (NSID): Indicates the namespace that the Failing +LBA occurred on. Valid only when the NSID Valid bit +(#NVME_ST_VALID_DIAG_INFO_NSID) is set in the Valid Diagnostic +Information (\fIvdi\fP) field. +.IP "flba" 12 +Failing LBA: indicates the LBA of the logical block that caused the +test to fail. If the device encountered more than one failed logical +block during the test, then this field only indicates one of those +failed logical blocks. Valid only when the NSID Valid bit +(#NVME_ST_VALID_DIAG_INFO_FLBA) is set in the Valid Diagnostic +Information (\fIvdi\fP) field. +.IP "sct" 12 +Status Code Type: This field may contain additional information related +to errors or conditions. Bits 2:0 may contain additional information +relating to errors or conditions that occurred during the device +self-test operation represented in the same format used in the Status +Code Type field of the completion queue entry (refer to \fIenum nvme_status_field\fP). +Valid only when the NSID Valid bit (#NVME_ST_VALID_DIAG_INFO_SCT) is +set in the Valid Diagnostic Information (\fIvdi\fP) field. +.IP "sc" 12 +Status Code: This field may contain additional information relating +to errors or conditions that occurred during the device self-test +operation represented in the same format used in the Status Code field +of the completion queue entry. Valid only when the SCT Valid bit +(#NVME_ST_VALID_DIAG_INFO_SC) is set in the Valid Diagnostic +Information (\fIvdi\fP) field. +.IP "vs" 12 +Vendor Specific. |