summaryrefslogtreecommitdiffstats
path: root/fs/zonefs/super.c
diff options
context:
space:
mode:
Diffstat (limited to '')
-rw-r--r--fs/zonefs/super.c66
1 files changed, 38 insertions, 28 deletions
diff --git a/fs/zonefs/super.c b/fs/zonefs/super.c
index 270ded209..f6b701261 100644
--- a/fs/zonefs/super.c
+++ b/fs/zonefs/super.c
@@ -245,16 +245,18 @@ static void zonefs_inode_update_mode(struct inode *inode)
z->z_flags &= ~ZONEFS_ZONE_INIT_MODE;
}
-struct zonefs_ioerr_data {
- struct inode *inode;
- bool write;
-};
-
static int zonefs_io_error_cb(struct blk_zone *zone, unsigned int idx,
void *data)
{
- struct zonefs_ioerr_data *err = data;
- struct inode *inode = err->inode;
+ struct blk_zone *z = data;
+
+ *z = *zone;
+ return 0;
+}
+
+static void zonefs_handle_io_error(struct inode *inode, struct blk_zone *zone,
+ bool write)
+{
struct zonefs_zone *z = zonefs_inode_zone(inode);
struct super_block *sb = inode->i_sb;
struct zonefs_sb_info *sbi = ZONEFS_SB(sb);
@@ -269,8 +271,8 @@ static int zonefs_io_error_cb(struct blk_zone *zone, unsigned int idx,
data_size = zonefs_check_zone_condition(sb, z, zone);
isize = i_size_read(inode);
if (!(z->z_flags & (ZONEFS_ZONE_READONLY | ZONEFS_ZONE_OFFLINE)) &&
- !err->write && isize == data_size)
- return 0;
+ !write && isize == data_size)
+ return;
/*
* At this point, we detected either a bad zone or an inconsistency
@@ -291,7 +293,7 @@ static int zonefs_io_error_cb(struct blk_zone *zone, unsigned int idx,
* In all cases, warn about inode size inconsistency and handle the
* IO error according to the zone condition and to the mount options.
*/
- if (zonefs_zone_is_seq(z) && isize != data_size)
+ if (isize != data_size)
zonefs_warn(sb,
"inode %lu: invalid size %lld (should be %lld)\n",
inode->i_ino, isize, data_size);
@@ -351,8 +353,6 @@ static int zonefs_io_error_cb(struct blk_zone *zone, unsigned int idx,
zonefs_i_size_write(inode, data_size);
z->z_wpoffset = data_size;
zonefs_inode_account_active(inode);
-
- return 0;
}
/*
@@ -366,23 +366,25 @@ void __zonefs_io_error(struct inode *inode, bool write)
{
struct zonefs_zone *z = zonefs_inode_zone(inode);
struct super_block *sb = inode->i_sb;
- struct zonefs_sb_info *sbi = ZONEFS_SB(sb);
unsigned int noio_flag;
- unsigned int nr_zones = 1;
- struct zonefs_ioerr_data err = {
- .inode = inode,
- .write = write,
- };
+ struct blk_zone zone;
int ret;
/*
- * The only files that have more than one zone are conventional zone
- * files with aggregated conventional zones, for which the inode zone
- * size is always larger than the device zone size.
+ * Conventional zone have no write pointer and cannot become read-only
+ * or offline. So simply fake a report for a single or aggregated zone
+ * and let zonefs_handle_io_error() correct the zone inode information
+ * according to the mount options.
*/
- if (z->z_size > bdev_zone_sectors(sb->s_bdev))
- nr_zones = z->z_size >>
- (sbi->s_zone_sectors_shift + SECTOR_SHIFT);
+ if (!zonefs_zone_is_seq(z)) {
+ zone.start = z->z_sector;
+ zone.len = z->z_size >> SECTOR_SHIFT;
+ zone.wp = zone.start + zone.len;
+ zone.type = BLK_ZONE_TYPE_CONVENTIONAL;
+ zone.cond = BLK_ZONE_COND_NOT_WP;
+ zone.capacity = zone.len;
+ goto handle_io_error;
+ }
/*
* Memory allocations in blkdev_report_zones() can trigger a memory
@@ -393,12 +395,20 @@ void __zonefs_io_error(struct inode *inode, bool write)
* the GFP_NOIO context avoids both problems.
*/
noio_flag = memalloc_noio_save();
- ret = blkdev_report_zones(sb->s_bdev, z->z_sector, nr_zones,
- zonefs_io_error_cb, &err);
- if (ret != nr_zones)
+ ret = blkdev_report_zones(sb->s_bdev, z->z_sector, 1,
+ zonefs_io_error_cb, &zone);
+ memalloc_noio_restore(noio_flag);
+
+ if (ret != 1) {
zonefs_err(sb, "Get inode %lu zone information failed %d\n",
inode->i_ino, ret);
- memalloc_noio_restore(noio_flag);
+ zonefs_warn(sb, "remounting filesystem read-only\n");
+ sb->s_flags |= SB_RDONLY;
+ return;
+ }
+
+handle_io_error:
+ zonefs_handle_io_error(inode, &zone, write);
}
static struct kmem_cache *zonefs_inode_cachep;