diff options
Diffstat (limited to '')
-rw-r--r-- | Documentation/ABI/testing/sysfs-bus-counter-104-quad-8 | 61 |
1 files changed, 61 insertions, 0 deletions
diff --git a/Documentation/ABI/testing/sysfs-bus-counter-104-quad-8 b/Documentation/ABI/testing/sysfs-bus-counter-104-quad-8 new file mode 100644 index 000000000..eac32180c --- /dev/null +++ b/Documentation/ABI/testing/sysfs-bus-counter-104-quad-8 @@ -0,0 +1,61 @@ +What: /sys/bus/counter/devices/counterX/signalY/cable_fault +KernelVersion: 5.7 +Contact: linux-iio@vger.kernel.org +Description: + Read-only attribute that indicates whether a differential + encoder cable fault (not connected or loose wires) is detected + for the respective channel of Signal Y. Valid attribute values + are boolean. Detection must first be enabled via the + corresponding cable_fault_enable attribute. + +What: /sys/bus/counter/devices/counterX/signalY/cable_fault_enable +KernelVersion: 5.7 +Contact: linux-iio@vger.kernel.org +Description: + Whether detection of differential encoder cable faults for the + respective channel of Signal Y is enabled. Valid attribute + values are boolean. + +What: /sys/bus/counter/devices/counterX/signalY/filter_clock_prescaler +KernelVersion: 5.7 +Contact: linux-iio@vger.kernel.org +Description: + Filter clock factor for input Signal Y. This prescaler value + affects the inputs of both quadrature pair signals. + +What: /sys/bus/counter/devices/counterX/signalY/index_polarity +KernelVersion: 5.2 +Contact: linux-iio@vger.kernel.org +Description: + Active level of index input Signal Y; irrelevant in + non-synchronous load mode. + +What: /sys/bus/counter/devices/counterX/signalY/index_polarity_available +What: /sys/bus/counter/devices/counterX/signalY/synchronous_mode_available +KernelVersion: 5.2 +Contact: linux-iio@vger.kernel.org +Description: + Discrete set of available values for the respective Signal Y + configuration are listed in this file. + +What: /sys/bus/counter/devices/counterX/signalY/synchronous_mode +KernelVersion: 5.2 +Contact: linux-iio@vger.kernel.org +Description: + Configure the counter associated with Signal Y for + non-synchronous or synchronous load mode. Synchronous load mode + cannot be selected in non-quadrature (Pulse-Direction) clock + mode. + + non-synchronous: + A logic low level is the active level at this index + input. The index function (as enabled via preset_enable) + is performed directly on the active level of the index + input. + + synchronous: + Intended for interfacing with encoder Index output in + quadrature clock mode. The active level is configured + via index_polarity. The index function (as enabled via + preset_enable) is performed synchronously with the + quadrature clock on the active level of the index input. |