diff options
Diffstat (limited to '')
-rw-r--r-- | fs/zonefs/super.c | 68 |
1 files changed, 39 insertions, 29 deletions
diff --git a/fs/zonefs/super.c b/fs/zonefs/super.c index b9522eee1..f9ecade9e 100644 --- a/fs/zonefs/super.c +++ b/fs/zonefs/super.c @@ -319,16 +319,18 @@ static loff_t zonefs_check_zone_condition(struct inode *inode, } } -struct zonefs_ioerr_data { - struct inode *inode; - bool write; -}; - static int zonefs_io_error_cb(struct blk_zone *zone, unsigned int idx, void *data) { - struct zonefs_ioerr_data *err = data; - struct inode *inode = err->inode; + struct blk_zone *z = data; + + *z = *zone; + return 0; +} + +static void zonefs_handle_io_error(struct inode *inode, struct blk_zone *zone, + bool write) +{ struct zonefs_inode_info *zi = ZONEFS_I(inode); struct super_block *sb = inode->i_sb; struct zonefs_sb_info *sbi = ZONEFS_SB(sb); @@ -344,8 +346,8 @@ static int zonefs_io_error_cb(struct blk_zone *zone, unsigned int idx, isize = i_size_read(inode); if (zone->cond != BLK_ZONE_COND_OFFLINE && zone->cond != BLK_ZONE_COND_READONLY && - !err->write && isize == data_size) - return 0; + !write && isize == data_size) + return; /* * At this point, we detected either a bad zone or an inconsistency @@ -366,8 +368,9 @@ static int zonefs_io_error_cb(struct blk_zone *zone, unsigned int idx, * In all cases, warn about inode size inconsistency and handle the * IO error according to the zone condition and to the mount options. */ - if (zi->i_ztype == ZONEFS_ZTYPE_SEQ && isize != data_size) - zonefs_warn(sb, "inode %lu: invalid size %lld (should be %lld)\n", + if (isize != data_size) + zonefs_warn(sb, + "inode %lu: invalid size %lld (should be %lld)\n", inode->i_ino, isize, data_size); /* @@ -427,8 +430,6 @@ static int zonefs_io_error_cb(struct blk_zone *zone, unsigned int idx, zonefs_update_stats(inode, data_size); zonefs_i_size_write(inode, data_size); zi->i_wpoffset = data_size; - - return 0; } /* @@ -442,23 +443,25 @@ static void __zonefs_io_error(struct inode *inode, bool write) { struct zonefs_inode_info *zi = ZONEFS_I(inode); struct super_block *sb = inode->i_sb; - struct zonefs_sb_info *sbi = ZONEFS_SB(sb); unsigned int noio_flag; - unsigned int nr_zones = 1; - struct zonefs_ioerr_data err = { - .inode = inode, - .write = write, - }; + struct blk_zone zone; int ret; /* - * The only files that have more than one zone are conventional zone - * files with aggregated conventional zones, for which the inode zone - * size is always larger than the device zone size. + * Conventional zone have no write pointer and cannot become read-only + * or offline. So simply fake a report for a single or aggregated zone + * and let zonefs_handle_io_error() correct the zone inode information + * according to the mount options. */ - if (zi->i_zone_size > bdev_zone_sectors(sb->s_bdev)) - nr_zones = zi->i_zone_size >> - (sbi->s_zone_sectors_shift + SECTOR_SHIFT); + if (zi->i_ztype != ZONEFS_ZTYPE_SEQ) { + zone.start = zi->i_zsector; + zone.len = zi->i_max_size >> SECTOR_SHIFT; + zone.wp = zone.start + zone.len; + zone.type = BLK_ZONE_TYPE_CONVENTIONAL; + zone.cond = BLK_ZONE_COND_NOT_WP; + zone.capacity = zone.len; + goto handle_io_error; + } /* * Memory allocations in blkdev_report_zones() can trigger a memory @@ -469,12 +472,19 @@ static void __zonefs_io_error(struct inode *inode, bool write) * the GFP_NOIO context avoids both problems. */ noio_flag = memalloc_noio_save(); - ret = blkdev_report_zones(sb->s_bdev, zi->i_zsector, nr_zones, - zonefs_io_error_cb, &err); - if (ret != nr_zones) + ret = blkdev_report_zones(sb->s_bdev, zi->i_zsector, 1, + zonefs_io_error_cb, &zone); + memalloc_noio_restore(noio_flag); + if (ret != 1) { zonefs_err(sb, "Get inode %lu zone information failed %d\n", inode->i_ino, ret); - memalloc_noio_restore(noio_flag); + zonefs_warn(sb, "remounting filesystem read-only\n"); + sb->s_flags |= SB_RDONLY; + return; + } + +handle_io_error: + zonefs_handle_io_error(inode, &zone, write); } static void zonefs_io_error(struct inode *inode, bool write) |