summaryrefslogtreecommitdiffstats
path: root/src/spdk/test/nvmf/nmic
diff options
context:
space:
mode:
authorDaniel Baumann <daniel.baumann@progress-linux.org>2024-04-27 18:24:20 +0000
committerDaniel Baumann <daniel.baumann@progress-linux.org>2024-04-27 18:24:20 +0000
commit483eb2f56657e8e7f419ab1a4fab8dce9ade8609 (patch)
treee5d88d25d870d5dedacb6bbdbe2a966086a0a5cf /src/spdk/test/nvmf/nmic
parentInitial commit. (diff)
downloadceph-483eb2f56657e8e7f419ab1a4fab8dce9ade8609.tar.xz
ceph-483eb2f56657e8e7f419ab1a4fab8dce9ade8609.zip
Adding upstream version 14.2.21.upstream/14.2.21upstream
Signed-off-by: Daniel Baumann <daniel.baumann@progress-linux.org>
Diffstat (limited to 'src/spdk/test/nvmf/nmic')
-rwxr-xr-xsrc/spdk/test/nvmf/nmic/nmic.sh87
1 files changed, 87 insertions, 0 deletions
diff --git a/src/spdk/test/nvmf/nmic/nmic.sh b/src/spdk/test/nvmf/nmic/nmic.sh
new file mode 100755
index 00000000..7b66a977
--- /dev/null
+++ b/src/spdk/test/nvmf/nmic/nmic.sh
@@ -0,0 +1,87 @@
+#!/usr/bin/env bash
+
+testdir=$(readlink -f $(dirname $0))
+rootdir=$(readlink -f $testdir/../../..)
+source $rootdir/test/common/autotest_common.sh
+source $rootdir/test/nvmf/common.sh
+
+MALLOC_BDEV_SIZE=128
+MALLOC_BLOCK_SIZE=512
+
+rpc_py="python $rootdir/scripts/rpc.py"
+
+set -e
+
+# pass the parameter 'iso' to this script when running it in isolation to trigger rdma device initialization.
+# e.g. sudo ./nmic.sh iso
+nvmftestinit $1
+
+RDMA_IP_LIST=$(get_available_rdma_ips)
+NVMF_FIRST_TARGET_IP=$(echo "$RDMA_IP_LIST" | head -n 1)
+NVMF_SECOND_TARGET_IP=$(echo "$RDMA_IP_LIST" | sed -n 2p)
+if [ -z $NVMF_FIRST_TARGET_IP ]; then
+ echo "no NIC for nvmf test"
+ exit 0
+fi
+
+timing_enter nmic
+timing_enter start_nvmf_tgt
+# Start up the NVMf target in another process
+$NVMF_APP -m 0xF &
+pid=$!
+
+trap "killprocess $pid; nvmftestfini $1; exit 1" SIGINT SIGTERM EXIT
+
+waitforlisten $pid
+$rpc_py nvmf_create_transport -t RDMA -u 8192 -p 4
+timing_exit start_nvmf_tgt
+
+# Create subsystems
+bdevs="$($rpc_py construct_malloc_bdev $MALLOC_BDEV_SIZE $MALLOC_BLOCK_SIZE)"
+$rpc_py nvmf_subsystem_create nqn.2016-06.io.spdk:cnode1 -a -s SPDK1
+for bdev in $bdevs; do
+ $rpc_py nvmf_subsystem_add_ns nqn.2016-06.io.spdk:cnode1 $bdev
+done
+$rpc_py nvmf_subsystem_add_listener nqn.2016-06.io.spdk:cnode1 -t RDMA -a $NVMF_FIRST_TARGET_IP -s "$NVMF_PORT"
+
+echo "test case1: single bdev can't be used in multiple subsystems"
+set +e
+$rpc_py nvmf_subsystem_create nqn.2016-06.io.spdk:cnode2 -a -s SPDK2
+$rpc_py nvmf_subsystem_add_listener nqn.2016-06.io.spdk:cnode2 -t RDMA -a $NVMF_FIRST_TARGET_IP -s "$NVMF_PORT"
+for bdev in $bdevs; do
+ $rpc_py nvmf_subsystem_add_ns nqn.2016-06.io.spdk:cnode2 $bdev
+ nmic_status=$?
+
+ if [ $nmic_status -eq 0 ]; then
+ echo " Adding namespace passed - failure expected."
+ killprocess $pid
+ exit 1
+ else
+ echo " Adding namespace failed - expected result."
+ fi
+done
+set -e
+
+modprobe -v nvme-rdma
+
+echo "test case2: host connect to nvmf target in multiple paths"
+if [ ! -z $NVMF_SECOND_TARGET_IP ]; then
+ $rpc_py nvmf_subsystem_add_listener nqn.2016-06.io.spdk:cnode1 -t RDMA -a $NVMF_SECOND_TARGET_IP -s $NVMF_PORT
+
+ nvme connect -t rdma -n "nqn.2016-06.io.spdk:cnode1" -a "$NVMF_FIRST_TARGET_IP" -s "$NVMF_PORT"
+ nvme connect -t rdma -n "nqn.2016-06.io.spdk:cnode1" -a "$NVMF_SECOND_TARGET_IP" -s "$NVMF_PORT"
+
+ waitforblk "nvme0n1"
+
+ $testdir/../fio/nvmf_fio.py 4096 1 write 1 verify
+fi
+
+nvme disconnect -n "nqn.2016-06.io.spdk:cnode1" || true
+
+trap - SIGINT SIGTERM EXIT
+
+nvmfcleanup
+killprocess $pid
+
+nvmftestfini $1
+timing_exit nmic