diff options
Diffstat (limited to 'src/spdk/test/nvmf/fio/fio.sh')
-rwxr-xr-x | src/spdk/test/nvmf/fio/fio.sh | 108 |
1 files changed, 108 insertions, 0 deletions
diff --git a/src/spdk/test/nvmf/fio/fio.sh b/src/spdk/test/nvmf/fio/fio.sh new file mode 100755 index 00000000..ba3b12b3 --- /dev/null +++ b/src/spdk/test/nvmf/fio/fio.sh @@ -0,0 +1,108 @@ +#!/usr/bin/env bash + +testdir=$(readlink -f $(dirname $0)) +rootdir=$(readlink -f $testdir/../../..) +source $rootdir/test/common/autotest_common.sh +source $rootdir/test/nvmf/common.sh + +MALLOC_BDEV_SIZE=64 +MALLOC_BLOCK_SIZE=512 + +rpc_py="$rootdir/scripts/rpc.py" + +set -e + +# pass the parameter 'iso' to this script when running it in isolation to trigger rdma device initialization. +# e.g. sudo ./fio.sh iso +nvmftestinit $1 + +RDMA_IP_LIST=$(get_available_rdma_ips) +NVMF_FIRST_TARGET_IP=$(echo "$RDMA_IP_LIST" | head -n 1) +if [ -z $NVMF_FIRST_TARGET_IP ]; then + echo "no NIC for nvmf test" + exit 0 +fi + +timing_enter fio +timing_enter start_nvmf_tgt +# Start up the NVMf target in another process +$NVMF_APP -m 0xF & +nvmfpid=$! + +trap "process_shm --id $NVMF_APP_SHM_ID; killprocess $nvmfpid; nvmftestfini $1; exit 1" SIGINT SIGTERM EXIT + +waitforlisten $nvmfpid +$rpc_py nvmf_create_transport -t RDMA -u 8192 -p 4 + +timing_exit start_nvmf_tgt + +malloc_bdevs="$($rpc_py construct_malloc_bdev $MALLOC_BDEV_SIZE $MALLOC_BLOCK_SIZE) " +malloc_bdevs+="$($rpc_py construct_malloc_bdev $MALLOC_BDEV_SIZE $MALLOC_BLOCK_SIZE)" +# Create a RAID-0 bdev from two malloc bdevs +raid_malloc_bdevs="$($rpc_py construct_malloc_bdev $MALLOC_BDEV_SIZE $MALLOC_BLOCK_SIZE) " +raid_malloc_bdevs+="$($rpc_py construct_malloc_bdev $MALLOC_BDEV_SIZE $MALLOC_BLOCK_SIZE)" +$rpc_py construct_raid_bdev -n raid0 -s 64 -r 0 -b "$raid_malloc_bdevs" + +modprobe -v nvme-rdma + +$rpc_py nvmf_subsystem_create nqn.2016-06.io.spdk:cnode1 -a -s SPDK00000000000001 +for malloc_bdev in $malloc_bdevs; do + $rpc_py nvmf_subsystem_add_ns nqn.2016-06.io.spdk:cnode1 "$malloc_bdev" +done +$rpc_py nvmf_subsystem_add_listener nqn.2016-06.io.spdk:cnode1 -t rdma -a $NVMF_FIRST_TARGET_IP -s 4420 + +# Append the raid0 bdev into subsystem +$rpc_py nvmf_subsystem_add_ns nqn.2016-06.io.spdk:cnode1 raid0 + +nvme connect -t rdma -n "nqn.2016-06.io.spdk:cnode1" -a "$NVMF_FIRST_TARGET_IP" -s "$NVMF_PORT" + +waitforblk "nvme0n1" +waitforblk "nvme0n2" +waitforblk "nvme0n3" + +$testdir/nvmf_fio.py 4096 1 write 1 verify +$testdir/nvmf_fio.py 4096 1 randwrite 1 verify +$testdir/nvmf_fio.py 4096 128 write 1 verify +$testdir/nvmf_fio.py 4096 128 randwrite 1 verify + +sync + +#start hotplug test case +$testdir/nvmf_fio.py 4096 1 read 10 & +fio_pid=$! + +sleep 3 +set +e + +$rpc_py destroy_raid_bdev "raid0" +for malloc_bdev in $malloc_bdevs; do + $rpc_py delete_malloc_bdev "$malloc_bdev" +done + +wait $fio_pid +fio_status=$? + +nvme disconnect -n "nqn.2016-06.io.spdk:cnode1" || true + +if [ $fio_status -eq 0 ]; then + echo "nvmf hotplug test: fio successful - expected failure" + nvmfcleanup + killprocess $nvmfpid + exit 1 +else + echo "nvmf hotplug test: fio failed as expected" +fi +set -e + +$rpc_py delete_nvmf_subsystem nqn.2016-06.io.spdk:cnode1 + +rm -f ./local-job0-0-verify.state +rm -f ./local-job1-1-verify.state +rm -f ./local-job2-2-verify.state + +trap - SIGINT SIGTERM EXIT + +nvmfcleanup +killprocess $nvmfpid +nvmftestfini $1 +timing_exit fio |