summaryrefslogtreecommitdiffstats
path: root/Documentation/ABI/testing/sysfs-bus-iio-adc-hi8435
diff options
context:
space:
mode:
authorDaniel Baumann <daniel.baumann@progress-linux.org>2024-04-27 10:05:51 +0000
committerDaniel Baumann <daniel.baumann@progress-linux.org>2024-04-27 10:05:51 +0000
commit5d1646d90e1f2cceb9f0828f4b28318cd0ec7744 (patch)
treea94efe259b9009378be6d90eb30d2b019d95c194 /Documentation/ABI/testing/sysfs-bus-iio-adc-hi8435
parentInitial commit. (diff)
downloadlinux-5d1646d90e1f2cceb9f0828f4b28318cd0ec7744.tar.xz
linux-5d1646d90e1f2cceb9f0828f4b28318cd0ec7744.zip
Adding upstream version 5.10.209.upstream/5.10.209upstream
Signed-off-by: Daniel Baumann <daniel.baumann@progress-linux.org>
Diffstat (limited to 'Documentation/ABI/testing/sysfs-bus-iio-adc-hi8435')
-rw-r--r--Documentation/ABI/testing/sysfs-bus-iio-adc-hi843548
1 files changed, 48 insertions, 0 deletions
diff --git a/Documentation/ABI/testing/sysfs-bus-iio-adc-hi8435 b/Documentation/ABI/testing/sysfs-bus-iio-adc-hi8435
new file mode 100644
index 000000000..4b01150af
--- /dev/null
+++ b/Documentation/ABI/testing/sysfs-bus-iio-adc-hi8435
@@ -0,0 +1,48 @@
+What: /sys/bus/iio/devices/iio:deviceX/in_voltageY_sensing_mode
+Date: August 2015
+KernelVersion: 4.2.0
+Contact: source@cogentembedded.com
+Description:
+ Program sensor type for threshold detector inputs.
+ Could be either "GND-Open" or "Supply-Open" mode. Y is a
+ threshold detector input channel. Channels 0..7, 8..15, 16..23
+ and 24..31 has common sensor types.
+
+What: /sys/bus/iio/devices/iio:deviceX/events/in_voltageY_thresh_falling_value
+Date: August 2015
+KernelVersion: 4.2.0
+Contact: source@cogentembedded.com
+Description:
+ Channel Y low voltage threshold. If sensor input voltage goes lower then
+ this value then the threshold falling event is pushed.
+ Depending on in_voltageY_sensing_mode the low voltage threshold
+ is separately set for "GND-Open" and "Supply-Open" modes.
+ Channels 0..31 have common low threshold values, but could have different
+ sensing_modes.
+
+ The low voltage threshold range is between 2..21V.
+ Hysteresis between low and high thresholds can not be lower then 2 and
+ can not be odd.
+
+ If falling threshold results hysteresis to odd value then rising
+ threshold is automatically subtracted by one.
+
+What: /sys/bus/iio/devices/iio:deviceX/events/in_voltageY_thresh_rising_value
+Date: August 2015
+KernelVersion: 4.2.0
+Contact: source@cogentembedded.com
+Description:
+ Channel Y high voltage threshold. If sensor input voltage goes higher then
+ this value then the threshold rising event is pushed.
+ Depending on in_voltageY_sensing_mode the high voltage threshold
+ is separately set for "GND-Open" and "Supply-Open" modes.
+
+ Channels 0..31 have common high threshold values, but could have different
+ sensing_modes.
+
+ The high voltage threshold range is between 3..22V.
+ Hysteresis between low and high thresholds can not be lower then 2 and
+ can not be odd.
+
+ If rising threshold results hysteresis to odd value then falling
+ threshold is automatically appended by one.