diff options
author | Daniel Baumann <daniel.baumann@progress-linux.org> | 2024-04-27 10:05:51 +0000 |
---|---|---|
committer | Daniel Baumann <daniel.baumann@progress-linux.org> | 2024-04-27 10:05:51 +0000 |
commit | 5d1646d90e1f2cceb9f0828f4b28318cd0ec7744 (patch) | |
tree | a94efe259b9009378be6d90eb30d2b019d95c194 /Documentation/hwmon/lm77.rst | |
parent | Initial commit. (diff) | |
download | linux-5d1646d90e1f2cceb9f0828f4b28318cd0ec7744.tar.xz linux-5d1646d90e1f2cceb9f0828f4b28318cd0ec7744.zip |
Adding upstream version 5.10.209.upstream/5.10.209upstream
Signed-off-by: Daniel Baumann <daniel.baumann@progress-linux.org>
Diffstat (limited to '')
-rw-r--r-- | Documentation/hwmon/lm77.rst | 45 |
1 files changed, 45 insertions, 0 deletions
diff --git a/Documentation/hwmon/lm77.rst b/Documentation/hwmon/lm77.rst new file mode 100644 index 000000000..4ed3fe6b9 --- /dev/null +++ b/Documentation/hwmon/lm77.rst @@ -0,0 +1,45 @@ +Kernel driver lm77 +================== + +Supported chips: + + * National Semiconductor LM77 + + Prefix: 'lm77' + + Addresses scanned: I2C 0x48 - 0x4b + + Datasheet: Publicly available at the National Semiconductor website + + http://www.national.com/ + + +Author: Andras BALI <drewie@freemail.hu> + +Description +----------- + +The LM77 implements one temperature sensor. The temperature +sensor incorporates a band-gap type temperature sensor, +10-bit ADC, and a digital comparator with user-programmable upper +and lower limit values. + +The LM77 implements 3 limits: low (temp1_min), high (temp1_max) and +critical (temp1_crit.) It also implements an hysteresis mechanism which +applies to all 3 limits. The relative difference is stored in a single +register on the chip, which means that the relative difference between +the limit and its hysteresis is always the same for all 3 limits. + +This implementation detail implies the following: + +* When setting a limit, its hysteresis will automatically follow, the + difference staying unchanged. For example, if the old critical limit + was 80 degrees C, and the hysteresis was 75 degrees C, and you change + the critical limit to 90 degrees C, then the hysteresis will + automatically change to 85 degrees C. +* All 3 hysteresis can't be set independently. We decided to make + temp1_crit_hyst writable, while temp1_min_hyst and temp1_max_hyst are + read-only. Setting temp1_crit_hyst writes the difference between + temp1_crit_hyst and temp1_crit into the chip, and the same relative + hysteresis applies automatically to the low and high limits. +* The limits should be set before the hysteresis. |