diff options
author | Daniel Baumann <daniel.baumann@progress-linux.org> | 2024-04-27 10:05:51 +0000 |
---|---|---|
committer | Daniel Baumann <daniel.baumann@progress-linux.org> | 2024-04-27 10:05:51 +0000 |
commit | 5d1646d90e1f2cceb9f0828f4b28318cd0ec7744 (patch) | |
tree | a94efe259b9009378be6d90eb30d2b019d95c194 /drivers/power/supply/ab8500_bmdata.c | |
parent | Initial commit. (diff) | |
download | linux-430c2fc249ea5c0536abd21c23382884005c9093.tar.xz linux-430c2fc249ea5c0536abd21c23382884005c9093.zip |
Adding upstream version 5.10.209.upstream/5.10.209upstream
Signed-off-by: Daniel Baumann <daniel.baumann@progress-linux.org>
Diffstat (limited to 'drivers/power/supply/ab8500_bmdata.c')
-rw-r--r-- | drivers/power/supply/ab8500_bmdata.c | 544 |
1 files changed, 544 insertions, 0 deletions
diff --git a/drivers/power/supply/ab8500_bmdata.c b/drivers/power/supply/ab8500_bmdata.c new file mode 100644 index 000000000..f6a66979c --- /dev/null +++ b/drivers/power/supply/ab8500_bmdata.c @@ -0,0 +1,544 @@ +// SPDX-License-Identifier: GPL-2.0 +#include <linux/export.h> +#include <linux/power_supply.h> +#include <linux/of.h> +#include <linux/mfd/abx500.h> +#include <linux/mfd/abx500/ab8500.h> +#include <linux/mfd/abx500/ab8500-bm.h> + +/* + * These are the defined batteries that uses a NTC and ID resistor placed + * inside of the battery pack. + * Note that the res_to_temp table must be strictly sorted by falling resistance + * values to work. + */ +const struct abx500_res_to_temp ab8500_temp_tbl_a_thermistor[] = { + {-5, 53407}, + { 0, 48594}, + { 5, 43804}, + {10, 39188}, + {15, 34870}, + {20, 30933}, + {25, 27422}, + {30, 24347}, + {35, 21694}, + {40, 19431}, + {45, 17517}, + {50, 15908}, + {55, 14561}, + {60, 13437}, + {65, 12500}, +}; +EXPORT_SYMBOL(ab8500_temp_tbl_a_thermistor); + +const int ab8500_temp_tbl_a_size = ARRAY_SIZE(ab8500_temp_tbl_a_thermistor); +EXPORT_SYMBOL(ab8500_temp_tbl_a_size); + +const struct abx500_res_to_temp ab8500_temp_tbl_b_thermistor[] = { + {-5, 200000}, + { 0, 159024}, + { 5, 151921}, + {10, 144300}, + {15, 136424}, + {20, 128565}, + {25, 120978}, + {30, 113875}, + {35, 107397}, + {40, 101629}, + {45, 96592}, + {50, 92253}, + {55, 88569}, + {60, 85461}, + {65, 82869}, +}; +EXPORT_SYMBOL(ab8500_temp_tbl_b_thermistor); + +const int ab8500_temp_tbl_b_size = ARRAY_SIZE(ab8500_temp_tbl_b_thermistor); +EXPORT_SYMBOL(ab8500_temp_tbl_b_size); + +static const struct abx500_v_to_cap cap_tbl_a_thermistor[] = { + {4171, 100}, + {4114, 95}, + {4009, 83}, + {3947, 74}, + {3907, 67}, + {3863, 59}, + {3830, 56}, + {3813, 53}, + {3791, 46}, + {3771, 33}, + {3754, 25}, + {3735, 20}, + {3717, 17}, + {3681, 13}, + {3664, 8}, + {3651, 6}, + {3635, 5}, + {3560, 3}, + {3408, 1}, + {3247, 0}, +}; + +static const struct abx500_v_to_cap cap_tbl_b_thermistor[] = { + {4161, 100}, + {4124, 98}, + {4044, 90}, + {4003, 85}, + {3966, 80}, + {3933, 75}, + {3888, 67}, + {3849, 60}, + {3813, 55}, + {3787, 47}, + {3772, 30}, + {3751, 25}, + {3718, 20}, + {3681, 16}, + {3660, 14}, + {3589, 10}, + {3546, 7}, + {3495, 4}, + {3404, 2}, + {3250, 0}, +}; + +static const struct abx500_v_to_cap cap_tbl[] = { + {4186, 100}, + {4163, 99}, + {4114, 95}, + {4068, 90}, + {3990, 80}, + {3926, 70}, + {3898, 65}, + {3866, 60}, + {3833, 55}, + {3812, 50}, + {3787, 40}, + {3768, 30}, + {3747, 25}, + {3730, 20}, + {3705, 15}, + {3699, 14}, + {3684, 12}, + {3672, 9}, + {3657, 7}, + {3638, 6}, + {3556, 4}, + {3424, 2}, + {3317, 1}, + {3094, 0}, +}; + +/* + * Note that the res_to_temp table must be strictly sorted by falling + * resistance values to work. + */ +static const struct abx500_res_to_temp temp_tbl[] = { + {-5, 214834}, + { 0, 162943}, + { 5, 124820}, + {10, 96520}, + {15, 75306}, + {20, 59254}, + {25, 47000}, + {30, 37566}, + {35, 30245}, + {40, 24520}, + {45, 20010}, + {50, 16432}, + {55, 13576}, + {60, 11280}, + {65, 9425}, +}; + +/* + * Note that the batres_vs_temp table must be strictly sorted by falling + * temperature values to work. + */ +static const struct batres_vs_temp temp_to_batres_tbl_thermistor[] = { + { 40, 120}, + { 30, 135}, + { 20, 165}, + { 10, 230}, + { 00, 325}, + {-10, 445}, + {-20, 595}, +}; + +/* + * Note that the batres_vs_temp table must be strictly sorted by falling + * temperature values to work. + */ +static const struct batres_vs_temp temp_to_batres_tbl_ext_thermistor[] = { + { 60, 300}, + { 30, 300}, + { 20, 300}, + { 10, 300}, + { 00, 300}, + {-10, 300}, + {-20, 300}, +}; + +/* battery resistance table for LI ION 9100 battery */ +static const struct batres_vs_temp temp_to_batres_tbl_9100[] = { + { 60, 180}, + { 30, 180}, + { 20, 180}, + { 10, 180}, + { 00, 180}, + {-10, 180}, + {-20, 180}, +}; + +static struct abx500_battery_type bat_type_thermistor[] = { + [BATTERY_UNKNOWN] = { + /* First element always represent the UNKNOWN battery */ + .name = POWER_SUPPLY_TECHNOLOGY_UNKNOWN, + .resis_high = 0, + .resis_low = 0, + .battery_resistance = 300, + .charge_full_design = 612, + .nominal_voltage = 3700, + .termination_vol = 4050, + .termination_curr = 200, + .recharge_cap = 95, + .normal_cur_lvl = 400, + .normal_vol_lvl = 4100, + .maint_a_cur_lvl = 400, + .maint_a_vol_lvl = 4050, + .maint_a_chg_timer_h = 60, + .maint_b_cur_lvl = 400, + .maint_b_vol_lvl = 4000, + .maint_b_chg_timer_h = 200, + .low_high_cur_lvl = 300, + .low_high_vol_lvl = 4000, + .n_temp_tbl_elements = ARRAY_SIZE(temp_tbl), + .r_to_t_tbl = temp_tbl, + .n_v_cap_tbl_elements = ARRAY_SIZE(cap_tbl), + .v_to_cap_tbl = cap_tbl, + .n_batres_tbl_elements = ARRAY_SIZE(temp_to_batres_tbl_thermistor), + .batres_tbl = temp_to_batres_tbl_thermistor, + }, + { + .name = POWER_SUPPLY_TECHNOLOGY_LIPO, + .resis_high = 53407, + .resis_low = 12500, + .battery_resistance = 300, + .charge_full_design = 900, + .nominal_voltage = 3600, + .termination_vol = 4150, + .termination_curr = 80, + .recharge_cap = 95, + .normal_cur_lvl = 700, + .normal_vol_lvl = 4200, + .maint_a_cur_lvl = 600, + .maint_a_vol_lvl = 4150, + .maint_a_chg_timer_h = 60, + .maint_b_cur_lvl = 600, + .maint_b_vol_lvl = 4100, + .maint_b_chg_timer_h = 200, + .low_high_cur_lvl = 300, + .low_high_vol_lvl = 4000, + .n_temp_tbl_elements = ARRAY_SIZE(ab8500_temp_tbl_a_thermistor), + .r_to_t_tbl = ab8500_temp_tbl_a_thermistor, + .n_v_cap_tbl_elements = ARRAY_SIZE(cap_tbl_a_thermistor), + .v_to_cap_tbl = cap_tbl_a_thermistor, + .n_batres_tbl_elements = ARRAY_SIZE(temp_to_batres_tbl_thermistor), + .batres_tbl = temp_to_batres_tbl_thermistor, + + }, + { + .name = POWER_SUPPLY_TECHNOLOGY_LIPO, + .resis_high = 200000, + .resis_low = 82869, + .battery_resistance = 300, + .charge_full_design = 900, + .nominal_voltage = 3600, + .termination_vol = 4150, + .termination_curr = 80, + .recharge_cap = 95, + .normal_cur_lvl = 700, + .normal_vol_lvl = 4200, + .maint_a_cur_lvl = 600, + .maint_a_vol_lvl = 4150, + .maint_a_chg_timer_h = 60, + .maint_b_cur_lvl = 600, + .maint_b_vol_lvl = 4100, + .maint_b_chg_timer_h = 200, + .low_high_cur_lvl = 300, + .low_high_vol_lvl = 4000, + .n_temp_tbl_elements = ARRAY_SIZE(ab8500_temp_tbl_b_thermistor), + .r_to_t_tbl = ab8500_temp_tbl_b_thermistor, + .n_v_cap_tbl_elements = ARRAY_SIZE(cap_tbl_b_thermistor), + .v_to_cap_tbl = cap_tbl_b_thermistor, + .n_batres_tbl_elements = ARRAY_SIZE(temp_to_batres_tbl_thermistor), + .batres_tbl = temp_to_batres_tbl_thermistor, + }, +}; + +static struct abx500_battery_type bat_type_ext_thermistor[] = { + [BATTERY_UNKNOWN] = { + /* First element always represent the UNKNOWN battery */ + .name = POWER_SUPPLY_TECHNOLOGY_UNKNOWN, + .resis_high = 0, + .resis_low = 0, + .battery_resistance = 300, + .charge_full_design = 612, + .nominal_voltage = 3700, + .termination_vol = 4050, + .termination_curr = 200, + .recharge_cap = 95, + .normal_cur_lvl = 400, + .normal_vol_lvl = 4100, + .maint_a_cur_lvl = 400, + .maint_a_vol_lvl = 4050, + .maint_a_chg_timer_h = 60, + .maint_b_cur_lvl = 400, + .maint_b_vol_lvl = 4000, + .maint_b_chg_timer_h = 200, + .low_high_cur_lvl = 300, + .low_high_vol_lvl = 4000, + .n_temp_tbl_elements = ARRAY_SIZE(temp_tbl), + .r_to_t_tbl = temp_tbl, + .n_v_cap_tbl_elements = ARRAY_SIZE(cap_tbl), + .v_to_cap_tbl = cap_tbl, + .n_batres_tbl_elements = ARRAY_SIZE(temp_to_batres_tbl_thermistor), + .batres_tbl = temp_to_batres_tbl_thermistor, + }, +/* + * These are the batteries that doesn't have an internal NTC resistor to measure + * its temperature. The temperature in this case is measure with a NTC placed + * near the battery but on the PCB. + */ + { + .name = POWER_SUPPLY_TECHNOLOGY_LIPO, + .resis_high = 76000, + .resis_low = 53000, + .battery_resistance = 300, + .charge_full_design = 900, + .nominal_voltage = 3700, + .termination_vol = 4150, + .termination_curr = 100, + .recharge_cap = 95, + .normal_cur_lvl = 700, + .normal_vol_lvl = 4200, + .maint_a_cur_lvl = 600, + .maint_a_vol_lvl = 4150, + .maint_a_chg_timer_h = 60, + .maint_b_cur_lvl = 600, + .maint_b_vol_lvl = 4100, + .maint_b_chg_timer_h = 200, + .low_high_cur_lvl = 300, + .low_high_vol_lvl = 4000, + .n_temp_tbl_elements = ARRAY_SIZE(temp_tbl), + .r_to_t_tbl = temp_tbl, + .n_v_cap_tbl_elements = ARRAY_SIZE(cap_tbl), + .v_to_cap_tbl = cap_tbl, + .n_batres_tbl_elements = ARRAY_SIZE(temp_to_batres_tbl_thermistor), + .batres_tbl = temp_to_batres_tbl_thermistor, + }, + { + .name = POWER_SUPPLY_TECHNOLOGY_LION, + .resis_high = 30000, + .resis_low = 10000, + .battery_resistance = 300, + .charge_full_design = 950, + .nominal_voltage = 3700, + .termination_vol = 4150, + .termination_curr = 100, + .recharge_cap = 95, + .normal_cur_lvl = 700, + .normal_vol_lvl = 4200, + .maint_a_cur_lvl = 600, + .maint_a_vol_lvl = 4150, + .maint_a_chg_timer_h = 60, + .maint_b_cur_lvl = 600, + .maint_b_vol_lvl = 4100, + .maint_b_chg_timer_h = 200, + .low_high_cur_lvl = 300, + .low_high_vol_lvl = 4000, + .n_temp_tbl_elements = ARRAY_SIZE(temp_tbl), + .r_to_t_tbl = temp_tbl, + .n_v_cap_tbl_elements = ARRAY_SIZE(cap_tbl), + .v_to_cap_tbl = cap_tbl, + .n_batres_tbl_elements = ARRAY_SIZE(temp_to_batres_tbl_thermistor), + .batres_tbl = temp_to_batres_tbl_thermistor, + }, + { + .name = POWER_SUPPLY_TECHNOLOGY_LION, + .resis_high = 95000, + .resis_low = 76001, + .battery_resistance = 300, + .charge_full_design = 950, + .nominal_voltage = 3700, + .termination_vol = 4150, + .termination_curr = 100, + .recharge_cap = 95, + .normal_cur_lvl = 700, + .normal_vol_lvl = 4200, + .maint_a_cur_lvl = 600, + .maint_a_vol_lvl = 4150, + .maint_a_chg_timer_h = 60, + .maint_b_cur_lvl = 600, + .maint_b_vol_lvl = 4100, + .maint_b_chg_timer_h = 200, + .low_high_cur_lvl = 300, + .low_high_vol_lvl = 4000, + .n_temp_tbl_elements = ARRAY_SIZE(temp_tbl), + .r_to_t_tbl = temp_tbl, + .n_v_cap_tbl_elements = ARRAY_SIZE(cap_tbl), + .v_to_cap_tbl = cap_tbl, + .n_batres_tbl_elements = ARRAY_SIZE(temp_to_batres_tbl_thermistor), + .batres_tbl = temp_to_batres_tbl_thermistor, + }, +}; + +static const struct abx500_bm_capacity_levels cap_levels = { + .critical = 2, + .low = 10, + .normal = 70, + .high = 95, + .full = 100, +}; + +static const struct abx500_fg_parameters fg = { + .recovery_sleep_timer = 10, + .recovery_total_time = 100, + .init_timer = 1, + .init_discard_time = 5, + .init_total_time = 40, + .high_curr_time = 60, + .accu_charging = 30, + .accu_high_curr = 30, + .high_curr_threshold = 50, + .lowbat_threshold = 3100, + .battok_falling_th_sel0 = 2860, + .battok_raising_th_sel1 = 2860, + .maint_thres = 95, + .user_cap_limit = 15, + .pcut_enable = 1, + .pcut_max_time = 127, + .pcut_flag_time = 112, + .pcut_max_restart = 15, + .pcut_debounce_time = 2, +}; + +static const struct abx500_maxim_parameters ab8500_maxi_params = { + .ena_maxi = true, + .chg_curr = 910, + .wait_cycles = 10, + .charger_curr_step = 100, +}; + +static const struct abx500_bm_charger_parameters chg = { + .usb_volt_max = 5500, + .usb_curr_max = 1500, + .ac_volt_max = 7500, + .ac_curr_max = 1500, +}; + +/* + * This array maps the raw hex value to charger output current used by the + * AB8500 values + */ +static int ab8500_charge_output_curr_map[] = { + 100, 200, 300, 400, 500, 600, 700, 800, + 900, 1000, 1100, 1200, 1300, 1400, 1500, 1500, +}; + +/* + * This array maps the raw hex value to charger input current used by the + * AB8500 values + */ +static int ab8500_charge_input_curr_map[] = { + 50, 98, 193, 290, 380, 450, 500, 600, + 700, 800, 900, 1000, 1100, 1300, 1400, 1500, +}; + +struct abx500_bm_data ab8500_bm_data = { + .temp_under = 3, + .temp_low = 8, + .temp_high = 43, + .temp_over = 48, + .main_safety_tmr_h = 4, + .temp_interval_chg = 20, + .temp_interval_nochg = 120, + .usb_safety_tmr_h = 4, + .bkup_bat_v = BUP_VCH_SEL_2P6V, + .bkup_bat_i = BUP_ICH_SEL_150UA, + .no_maintenance = false, + .capacity_scaling = false, + .adc_therm = ABx500_ADC_THERM_BATCTRL, + .chg_unknown_bat = false, + .enable_overshoot = false, + .fg_res = 100, + .cap_levels = &cap_levels, + .bat_type = bat_type_thermistor, + .n_btypes = ARRAY_SIZE(bat_type_thermistor), + .batt_id = 0, + .interval_charging = 5, + .interval_not_charging = 120, + .temp_hysteresis = 3, + .gnd_lift_resistance = 34, + .chg_output_curr = ab8500_charge_output_curr_map, + .n_chg_out_curr = ARRAY_SIZE(ab8500_charge_output_curr_map), + .maxi = &ab8500_maxi_params, + .chg_params = &chg, + .fg_params = &fg, + .chg_input_curr = ab8500_charge_input_curr_map, + .n_chg_in_curr = ARRAY_SIZE(ab8500_charge_input_curr_map), +}; + +int ab8500_bm_of_probe(struct device *dev, + struct device_node *np, + struct abx500_bm_data *bm) +{ + const struct batres_vs_temp *tmp_batres_tbl; + struct device_node *battery_node; + const char *btech; + int i; + + /* get phandle to 'battery-info' node */ + battery_node = of_parse_phandle(np, "battery", 0); + if (!battery_node) { + dev_err(dev, "battery node or reference missing\n"); + return -EINVAL; + } + + btech = of_get_property(battery_node, "stericsson,battery-type", NULL); + if (!btech) { + dev_warn(dev, "missing property battery-name/type\n"); + of_node_put(battery_node); + return -EINVAL; + } + + if (strncmp(btech, "LION", 4) == 0) { + bm->no_maintenance = true; + bm->chg_unknown_bat = true; + bm->bat_type[BATTERY_UNKNOWN].charge_full_design = 2600; + bm->bat_type[BATTERY_UNKNOWN].termination_vol = 4150; + bm->bat_type[BATTERY_UNKNOWN].recharge_cap = 95; + bm->bat_type[BATTERY_UNKNOWN].normal_cur_lvl = 520; + bm->bat_type[BATTERY_UNKNOWN].normal_vol_lvl = 4200; + } + + if (of_property_read_bool(battery_node, "thermistor-on-batctrl")) { + if (strncmp(btech, "LION", 4) == 0) + tmp_batres_tbl = temp_to_batres_tbl_9100; + else + tmp_batres_tbl = temp_to_batres_tbl_thermistor; + } else { + bm->n_btypes = 4; + bm->bat_type = bat_type_ext_thermistor; + bm->adc_therm = ABx500_ADC_THERM_BATTEMP; + tmp_batres_tbl = temp_to_batres_tbl_ext_thermistor; + } + + /* select the battery resolution table */ + for (i = 0; i < bm->n_btypes; ++i) + bm->bat_type[i].batres_tbl = tmp_batres_tbl; + + of_node_put(battery_node); + + return 0; +} |