summaryrefslogtreecommitdiffstats
path: root/Documentation/ABI/testing/sysfs-class-rapidio
diff options
context:
space:
mode:
Diffstat (limited to 'Documentation/ABI/testing/sysfs-class-rapidio')
-rw-r--r--Documentation/ABI/testing/sysfs-class-rapidio59
1 files changed, 59 insertions, 0 deletions
diff --git a/Documentation/ABI/testing/sysfs-class-rapidio b/Documentation/ABI/testing/sysfs-class-rapidio
new file mode 100644
index 000000000..19aefb21b
--- /dev/null
+++ b/Documentation/ABI/testing/sysfs-class-rapidio
@@ -0,0 +1,59 @@
+What: /sys/class/rapidio_port
+Description:
+ On-chip RapidIO controllers and PCIe-to-RapidIO bridges
+ (referenced as "Master Port" or "mport") are presented in sysfs
+ as the special class of devices: "rapidio_port".
+ The /sys/class/rapidio_port subdirectory contains individual
+ subdirectories named as "rapidioN" where N = mport ID registered
+ with RapidIO subsystem.
+
+ NOTE: An mport ID is not a RapidIO destination ID assigned to a
+ given local mport device.
+
+What: /sys/class/rapidio_port/rapidioN/sys_size
+Date: Apr, 2014
+KernelVersion: v3.15
+Contact: Matt Porter <mporter@kernel.crashing.org>,
+ Alexandre Bounine <alexandre.bounine@idt.com>
+Description:
+ (RO) reports RapidIO common transport system size:
+
+ 0 = small (8-bit destination ID, max. 256 devices),
+
+ 1 = large (16-bit destination ID, max. 65536 devices).
+
+What: /sys/class/rapidio_port/rapidioN/port_destid
+Date: Apr, 2014
+KernelVersion: v3.15
+Contact: Matt Porter <mporter@kernel.crashing.org>,
+ Alexandre Bounine <alexandre.bounine@idt.com>
+Description:
+
+(RO) reports RapidIO destination ID assigned to the given
+RapidIO mport device. If value 0xFFFFFFFF is returned this means
+that no valid destination ID have been assigned to the mport
+(yet). Normally, before enumeration/discovery have been executed
+only fabric enumerating mports have a valid destination ID
+assigned to them using "hdid=..." rapidio module parameter.
+
+After enumeration or discovery was performed for a given mport device,
+the corresponding subdirectory will also contain subdirectories for each
+child RapidIO device connected to the mport.
+
+The example below shows mport device subdirectory with several child RapidIO
+devices attached to it::
+
+ [rio@rapidio ~]$ ls /sys/class/rapidio_port/rapidio0/ -l
+ total 0
+ drwxr-xr-x 3 root root 0 Feb 11 15:10 00:e:0001
+ drwxr-xr-x 3 root root 0 Feb 11 15:10 00:e:0004
+ drwxr-xr-x 3 root root 0 Feb 11 15:10 00:e:0007
+ drwxr-xr-x 3 root root 0 Feb 11 15:10 00:s:0002
+ drwxr-xr-x 3 root root 0 Feb 11 15:10 00:s:0003
+ drwxr-xr-x 3 root root 0 Feb 11 15:10 00:s:0005
+ lrwxrwxrwx 1 root root 0 Feb 11 15:11 device -> ../../../0000:01:00.0
+ -r--r--r-- 1 root root 4096 Feb 11 15:11 port_destid
+ drwxr-xr-x 2 root root 0 Feb 11 15:11 power
+ lrwxrwxrwx 1 root root 0 Feb 11 15:04 subsystem -> ../../../../../../class/rapidio_port
+ -r--r--r-- 1 root root 4096 Feb 11 15:11 sys_size
+ -rw-r--r-- 1 root root 4096 Feb 11 15:04 uevent