summaryrefslogtreecommitdiffstats
path: root/Documentation/devicetree/bindings/iio/humidity
diff options
context:
space:
mode:
Diffstat (limited to 'Documentation/devicetree/bindings/iio/humidity')
-rw-r--r--Documentation/devicetree/bindings/iio/humidity/dht11.txt14
-rw-r--r--Documentation/devicetree/bindings/iio/humidity/hdc100x.txt17
-rw-r--r--Documentation/devicetree/bindings/iio/humidity/hts221.txt30
-rw-r--r--Documentation/devicetree/bindings/iio/humidity/htu21.txt13
-rw-r--r--Documentation/devicetree/bindings/iio/humidity/ti,hdc2010.yaml47
5 files changed, 121 insertions, 0 deletions
diff --git a/Documentation/devicetree/bindings/iio/humidity/dht11.txt b/Documentation/devicetree/bindings/iio/humidity/dht11.txt
new file mode 100644
index 000000000..ecc24c199
--- /dev/null
+++ b/Documentation/devicetree/bindings/iio/humidity/dht11.txt
@@ -0,0 +1,14 @@
+* DHT11 humidity/temperature sensor (and compatibles like DHT22)
+
+Required properties:
+ - compatible: Should be "dht11"
+ - gpios: Should specify the GPIO connected to the sensor's data
+ line, see "gpios property" in
+ Documentation/devicetree/bindings/gpio/gpio.txt.
+
+Example:
+
+humidity_sensor {
+ compatible = "dht11";
+ gpios = <&gpio0 6 0>;
+}
diff --git a/Documentation/devicetree/bindings/iio/humidity/hdc100x.txt b/Documentation/devicetree/bindings/iio/humidity/hdc100x.txt
new file mode 100644
index 000000000..c52333bdf
--- /dev/null
+++ b/Documentation/devicetree/bindings/iio/humidity/hdc100x.txt
@@ -0,0 +1,17 @@
+* HDC100x temperature + humidity sensors
+
+Required properties:
+ - compatible: Should contain one of the following:
+ ti,hdc1000
+ ti,hdc1008
+ ti,hdc1010
+ ti,hdc1050
+ ti,hdc1080
+ - reg: i2c address of the sensor
+
+Example:
+
+hdc100x@40 {
+ compatible = "ti,hdc1000";
+ reg = <0x40>;
+};
diff --git a/Documentation/devicetree/bindings/iio/humidity/hts221.txt b/Documentation/devicetree/bindings/iio/humidity/hts221.txt
new file mode 100644
index 000000000..84d029372
--- /dev/null
+++ b/Documentation/devicetree/bindings/iio/humidity/hts221.txt
@@ -0,0 +1,30 @@
+* HTS221 STM humidity + temperature sensor
+
+Required properties:
+- compatible: should be "st,hts221"
+- reg: i2c address of the sensor / spi cs line
+
+Optional properties:
+- drive-open-drain: the interrupt/data ready line will be configured
+ as open drain, which is useful if several sensors share the same
+ interrupt line. This is a boolean property.
+ If the requested interrupt is configured as IRQ_TYPE_LEVEL_HIGH or
+ IRQ_TYPE_EDGE_RISING a pull-down resistor is needed to drive the line
+ when it is not active, whereas a pull-up one is needed when interrupt
+ line is configured as IRQ_TYPE_LEVEL_LOW or IRQ_TYPE_EDGE_FALLING.
+ Refer to pinctrl/pinctrl-bindings.txt for the property description.
+- interrupts: interrupt mapping for IRQ. It should be configured with
+ flags IRQ_TYPE_LEVEL_HIGH, IRQ_TYPE_EDGE_RISING, IRQ_TYPE_LEVEL_LOW or
+ IRQ_TYPE_EDGE_FALLING.
+
+ Refer to interrupt-controller/interrupts.txt for generic interrupt
+ client node bindings.
+
+Example:
+
+hts221@5f {
+ compatible = "st,hts221";
+ reg = <0x5f>;
+ interrupt-parent = <&gpio0>;
+ interrupts = <0 IRQ_TYPE_EDGE_RISING>;
+};
diff --git a/Documentation/devicetree/bindings/iio/humidity/htu21.txt b/Documentation/devicetree/bindings/iio/humidity/htu21.txt
new file mode 100644
index 000000000..97d79636f
--- /dev/null
+++ b/Documentation/devicetree/bindings/iio/humidity/htu21.txt
@@ -0,0 +1,13 @@
+*HTU21 - Measurement-Specialties htu21 temperature & humidity sensor and humidity part of MS8607 sensor
+
+Required properties:
+
+ - compatible: should be "meas,htu21" or "meas,ms8607-humidity"
+ - reg: I2C address of the sensor
+
+Example:
+
+htu21@40 {
+ compatible = "meas,htu21";
+ reg = <0x40>;
+};
diff --git a/Documentation/devicetree/bindings/iio/humidity/ti,hdc2010.yaml b/Documentation/devicetree/bindings/iio/humidity/ti,hdc2010.yaml
new file mode 100644
index 000000000..7037f82ec
--- /dev/null
+++ b/Documentation/devicetree/bindings/iio/humidity/ti,hdc2010.yaml
@@ -0,0 +1,47 @@
+# SPDX-License-Identifier: (GPL-2.0-only OR BSD-2-Clause)
+%YAML 1.2
+---
+$id: http://devicetree.org/schemas/iio/humidity/ti,hdc2010.yaml#
+$schema: http://devicetree.org/meta-schemas/core.yaml#
+
+title: HDC2010/HDC2080 humidity and temperature iio sensors
+
+maintainers:
+ - Eugene Zaikonnikov <ez@norophonic.com>
+
+description: |
+ Relative humidity and tempereature sensors on I2C bus
+
+ Datasheets are available at:
+ http://www.ti.com/product/HDC2010/datasheet
+ http://www.ti.com/product/HDC2080/datasheet
+
+properties:
+ compatible:
+ enum:
+ - ti,hdc2010
+ - ti,hdc2080
+
+ vdd-supply:
+ maxItems: 1
+
+ reg:
+ maxItems: 1
+
+required:
+ - compatible
+ - reg
+
+additionalProperties: false
+
+examples:
+ - |
+ i2c0 {
+ #address-cells = <1>;
+ #size-cells = <0>;
+
+ humidity@40 {
+ compatible = "ti,hdc2010";
+ reg = <0x40>;
+ };
+ };