summaryrefslogtreecommitdiffstats
path: root/Documentation/devicetree/bindings/power/supply/charger-manager.txt
diff options
context:
space:
mode:
Diffstat (limited to '')
-rw-r--r--Documentation/devicetree/bindings/power/supply/charger-manager.txt91
1 files changed, 91 insertions, 0 deletions
diff --git a/Documentation/devicetree/bindings/power/supply/charger-manager.txt b/Documentation/devicetree/bindings/power/supply/charger-manager.txt
new file mode 100644
index 000000000..b5ae9061b
--- /dev/null
+++ b/Documentation/devicetree/bindings/power/supply/charger-manager.txt
@@ -0,0 +1,91 @@
+charger-manager bindings
+~~~~~~~~~~~~~~~~~~~~~~~~
+
+Required properties :
+ - compatible : "charger-manager"
+ - <>-supply : for regulator consumer, named according to cm-regulator-name
+ - cm-chargers : name of chargers
+ - cm-fuel-gauge : name of battery fuel gauge
+ - subnode <regulator> :
+ - cm-regulator-name : name of charger regulator
+ - subnode <cable> :
+ - cm-cable-name : name of charger cable - one of USB, USB-HOST,
+ SDP, DCP, CDP, ACA, FAST-CHARGER, SLOW-CHARGER, WPT,
+ PD, DOCK, JIG, or MECHANICAL
+ - cm-cable-extcon : name of extcon dev
+(optional) - cm-cable-min : minimum current of cable
+(optional) - cm-cable-max : maximum current of cable
+
+Optional properties :
+ - cm-name : charger manager's name (default : "battery")
+ - cm-poll-mode : polling mode - 0 for disabled, 1 for always, 2 for when
+ external power is connected, or 3 for when charging. If not present,
+ then polling is disabled
+ - cm-poll-interval : polling interval (in ms)
+ - cm-battery-stat : battery status - 0 for battery always present, 1 for no
+ battery, 2 to check presence via fuel gauge, or 3 to check presence
+ via charger
+ - cm-fullbatt-vchkdrop-volt : voltage drop (in uV) before restarting charging
+ - cm-fullbatt-voltage : voltage (in uV) of full battery
+ - cm-fullbatt-soc : state of charge to consider as full battery
+ - cm-fullbatt-capacity : capcity (in uAh) to consider as full battery
+ - cm-thermal-zone : name of external thermometer's thermal zone
+ - cm-battery-* : threshold battery temperature for charging
+ -cold : critical cold temperature of battery for charging
+ -cold-in-minus : flag that cold temperature is in minus degrees
+ -hot : critical hot temperature of battery for charging
+ -temp-diff : temperature difference to allow recharging
+ - cm-dis/charging-max = limits of charging duration
+
+Deprecated properties:
+ - cm-num-chargers
+ - cm-fullbatt-vchkdrop-ms
+
+Example :
+ charger-manager@0 {
+ compatible = "charger-manager";
+ chg-reg-supply = <&charger_regulator>;
+
+ cm-name = "battery";
+ /* Always polling ON : 30s */
+ cm-poll-mode = <1>;
+ cm-poll-interval = <30000>;
+
+ cm-fullbatt-vchkdrop-volt = <150000>;
+ cm-fullbatt-soc = <100>;
+
+ cm-battery-stat = <3>;
+
+ cm-chargers = "charger0", "charger1", "charger2";
+
+ cm-fuel-gauge = "fuelgauge0";
+
+ cm-thermal-zone = "thermal_zone.1"
+ /* in deci centigrade */
+ cm-battery-cold = <50>;
+ cm-battery-cold-in-minus;
+ cm-battery-hot = <800>;
+ cm-battery-temp-diff = <100>;
+
+ /* Allow charging for 5hr */
+ cm-charging-max = <18000000>;
+ /* Allow discharging for 2hr */
+ cm-discharging-max = <7200000>;
+
+ regulator@0 {
+ cm-regulator-name = "chg-reg";
+ cable@0 {
+ cm-cable-name = "USB";
+ cm-cable-extcon = "extcon-dev.0";
+ cm-cable-min = <475000>;
+ cm-cable-max = <500000>;
+ };
+ cable@1 {
+ cm-cable-name = "SDP";
+ cm-cable-extcon = "extcon-dev.0";
+ cm-cable-min = <650000>;
+ cm-cable-max = <675000>;
+ };
+ };
+
+ };