diff options
Diffstat (limited to 'Documentation/devicetree/bindings/thermal/thermal-cooling-devices.yaml')
-rw-r--r-- | Documentation/devicetree/bindings/thermal/thermal-cooling-devices.yaml | 118 |
1 files changed, 118 insertions, 0 deletions
diff --git a/Documentation/devicetree/bindings/thermal/thermal-cooling-devices.yaml b/Documentation/devicetree/bindings/thermal/thermal-cooling-devices.yaml new file mode 100644 index 000000000..f004779ba --- /dev/null +++ b/Documentation/devicetree/bindings/thermal/thermal-cooling-devices.yaml @@ -0,0 +1,118 @@ +# SPDX-License-Identifier: (GPL-2.0) +# Copyright 2020 Linaro Ltd. +%YAML 1.2 +--- +$id: http://devicetree.org/schemas/thermal/thermal-cooling-devices.yaml# +$schema: http://devicetree.org/meta-schemas/core.yaml# + +title: Thermal cooling device binding + +maintainers: + - Amit Kucheria <amitk@kernel.org> + +description: | + Thermal management is achieved in devicetree by describing the sensor hardware + and the software abstraction of cooling devices and thermal zones required to + take appropriate action to mitigate thermal overload. + + The following node types are used to completely describe a thermal management + system in devicetree: + - thermal-sensor: device that measures temperature, has SoC-specific bindings + - cooling-device: device used to dissipate heat either passively or actively + - thermal-zones: a container of the following node types used to describe all + thermal data for the platform + + This binding describes the cooling devices. + + There are essentially two ways to provide control on power dissipation: + - Passive cooling: by means of regulating device performance. A typical + passive cooling mechanism is a CPU that has dynamic voltage and frequency + scaling (DVFS), and uses lower frequencies as cooling states. + - Active cooling: by means of activating devices in order to remove the + dissipated heat, e.g. regulating fan speeds. + + Any cooling device has a range of cooling states (i.e. different levels of + heat dissipation). They also have a way to determine the state of cooling in + which the device is. For example, a fan's cooling states correspond to the + different fan speeds possible. Cooling states are referred to by single + unsigned integers, where larger numbers mean greater heat dissipation. The + precise set of cooling states associated with a device should be defined in + a particular device's binding. + +select: true + +properties: + "#cooling-cells": + description: + Must be 2, in order to specify minimum and maximum cooling state used in + the cooling-maps reference. The first cell is the minimum cooling state + and the second cell is the maximum cooling state requested. + const: 2 + +additionalProperties: true + +examples: + - | + #include <dt-bindings/interrupt-controller/arm-gic.h> + #include <dt-bindings/thermal/thermal.h> + + // Example 1: Cpufreq cooling device on CPU0 + cpus { + #address-cells = <2>; + #size-cells = <0>; + + CPU0: cpu@0 { + device_type = "cpu"; + compatible = "qcom,kryo385"; + reg = <0x0 0x0>; + enable-method = "psci"; + cpu-idle-states = <&LITTLE_CPU_SLEEP_0 + &LITTLE_CPU_SLEEP_1 + &CLUSTER_SLEEP_0>; + capacity-dmips-mhz = <607>; + dynamic-power-coefficient = <100>; + qcom,freq-domain = <&cpufreq_hw 0>; + #cooling-cells = <2>; + next-level-cache = <&L2_0>; + L2_0: l2-cache { + compatible = "cache"; + next-level-cache = <&L3_0>; + L3_0: l3-cache { + compatible = "cache"; + }; + }; + }; + + /* ... */ + + }; + + /* ... */ + + thermal-zones { + cpu0-thermal { + polling-delay-passive = <250>; + polling-delay = <1000>; + + thermal-sensors = <&tsens0 1>; + + trips { + cpu0_alert0: trip-point0 { + temperature = <90000>; + hysteresis = <2000>; + type = "passive"; + }; + }; + + cooling-maps { + map0 { + trip = <&cpu0_alert0>; + /* Corresponds to 1000MHz in OPP table */ + cooling-device = <&CPU0 5 5>; + }; + }; + }; + + /* ... */ + }; +... |