summaryrefslogtreecommitdiffstats
path: root/Documentation/input/devices/edt-ft5x06.rst
diff options
context:
space:
mode:
Diffstat (limited to '')
-rw-r--r--Documentation/input/devices/edt-ft5x06.rst54
1 files changed, 54 insertions, 0 deletions
diff --git a/Documentation/input/devices/edt-ft5x06.rst b/Documentation/input/devices/edt-ft5x06.rst
new file mode 100644
index 000000000..1ccc94b19
--- /dev/null
+++ b/Documentation/input/devices/edt-ft5x06.rst
@@ -0,0 +1,54 @@
+EDT ft5x06 based Polytouch devices
+----------------------------------
+
+The edt-ft5x06 driver is useful for the EDT "Polytouch" family of capacitive
+touch screens. Note that it is *not* suitable for other devices based on the
+focaltec ft5x06 devices, since they contain vendor-specific firmware. In
+particular this driver is not suitable for the Nook tablet.
+
+It has been tested with the following devices:
+ * EP0350M06
+ * EP0430M06
+ * EP0570M06
+ * EP0700M06
+
+The driver allows configuration of the touch screen via a set of sysfs files:
+
+/sys/class/input/eventX/device/device/threshold:
+ allows setting the "click"-threshold in the range from 0 to 80.
+
+/sys/class/input/eventX/device/device/gain:
+ allows setting the sensitivity in the range from 0 to 31. Note that
+ lower values indicate higher sensitivity.
+
+/sys/class/input/eventX/device/device/offset:
+ allows setting the edge compensation in the range from 0 to 31.
+
+/sys/class/input/eventX/device/device/report_rate:
+ allows setting the report rate in the range from 3 to 14.
+
+
+For debugging purposes the driver provides a few files in the debug
+filesystem (if available in the kernel). In /sys/kernel/debug/edt_ft5x06
+you'll find the following files:
+
+num_x, num_y:
+ (readonly) contains the number of sensor fields in X- and
+ Y-direction.
+
+mode:
+ allows switching the sensor between "factory mode" and "operation
+ mode" by writing "1" or "0" to it. In factory mode (1) it is
+ possible to get the raw data from the sensor. Note that in factory
+ mode regular events don't get delivered and the options described
+ above are unavailable.
+
+raw_data:
+ contains num_x * num_y big endian 16 bit values describing the raw
+ values for each sensor field. Note that each read() call on this
+ files triggers a new readout. It is recommended to provide a buffer
+ big enough to contain num_x * num_y * 2 bytes.
+
+Note that reading raw_data gives a I/O error when the device is not in factory
+mode. The same happens when reading/writing to the parameter files when the
+device is not in regular operation mode.