summaryrefslogtreecommitdiffstats
path: root/drivers/pci/hotplug/rpadlpar_core.c
diff options
context:
space:
mode:
Diffstat (limited to 'drivers/pci/hotplug/rpadlpar_core.c')
-rw-r--r--drivers/pci/hotplug/rpadlpar_core.c480
1 files changed, 480 insertions, 0 deletions
diff --git a/drivers/pci/hotplug/rpadlpar_core.c b/drivers/pci/hotplug/rpadlpar_core.c
new file mode 100644
index 000000000..0a3c80ba6
--- /dev/null
+++ b/drivers/pci/hotplug/rpadlpar_core.c
@@ -0,0 +1,480 @@
+// SPDX-License-Identifier: GPL-2.0+
+/*
+ * Interface for Dynamic Logical Partitioning of I/O Slots on
+ * RPA-compliant PPC64 platform.
+ *
+ * John Rose <johnrose@austin.ibm.com>
+ * Linda Xie <lxie@us.ibm.com>
+ *
+ * October 2003
+ *
+ * Copyright (C) 2003 IBM.
+ */
+
+#undef DEBUG
+
+#include <linux/init.h>
+#include <linux/module.h>
+#include <linux/pci.h>
+#include <linux/string.h>
+#include <linux/vmalloc.h>
+
+#include <asm/pci-bridge.h>
+#include <linux/mutex.h>
+#include <asm/rtas.h>
+#include <asm/vio.h>
+#include <linux/firmware.h>
+
+#include "../pci.h"
+#include "rpaphp.h"
+#include "rpadlpar.h"
+
+static DEFINE_MUTEX(rpadlpar_mutex);
+
+#define DLPAR_MODULE_NAME "rpadlpar_io"
+
+#define NODE_TYPE_VIO 1
+#define NODE_TYPE_SLOT 2
+#define NODE_TYPE_PHB 3
+
+static struct device_node *find_vio_slot_node(char *drc_name)
+{
+ struct device_node *parent = of_find_node_by_name(NULL, "vdevice");
+ struct device_node *dn;
+ int rc;
+
+ if (!parent)
+ return NULL;
+
+ for_each_child_of_node(parent, dn) {
+ rc = rpaphp_check_drc_props(dn, drc_name, NULL);
+ if (rc == 0)
+ break;
+ }
+ of_node_put(parent);
+
+ return dn;
+}
+
+/* Find dlpar-capable pci node that contains the specified name and type */
+static struct device_node *find_php_slot_pci_node(char *drc_name,
+ char *drc_type)
+{
+ struct device_node *np;
+ int rc;
+
+ for_each_node_by_name(np, "pci") {
+ rc = rpaphp_check_drc_props(np, drc_name, drc_type);
+ if (rc == 0)
+ break;
+ }
+
+ return np;
+}
+
+/* Returns a device_node with its reference count incremented */
+static struct device_node *find_dlpar_node(char *drc_name, int *node_type)
+{
+ struct device_node *dn;
+
+ dn = find_php_slot_pci_node(drc_name, "SLOT");
+ if (dn) {
+ *node_type = NODE_TYPE_SLOT;
+ return dn;
+ }
+
+ dn = find_php_slot_pci_node(drc_name, "PHB");
+ if (dn) {
+ *node_type = NODE_TYPE_PHB;
+ return dn;
+ }
+
+ dn = find_vio_slot_node(drc_name);
+ if (dn) {
+ *node_type = NODE_TYPE_VIO;
+ return dn;
+ }
+
+ return NULL;
+}
+
+/**
+ * find_php_slot - return hotplug slot structure for device node
+ * @dn: target &device_node
+ *
+ * This routine will return the hotplug slot structure
+ * for a given device node. Note that built-in PCI slots
+ * may be dlpar-able, but not hot-pluggable, so this routine
+ * will return NULL for built-in PCI slots.
+ */
+static struct slot *find_php_slot(struct device_node *dn)
+{
+ struct slot *slot, *next;
+
+ list_for_each_entry_safe(slot, next, &rpaphp_slot_head,
+ rpaphp_slot_list) {
+ if (slot->dn == dn)
+ return slot;
+ }
+
+ return NULL;
+}
+
+static struct pci_dev *dlpar_find_new_dev(struct pci_bus *parent,
+ struct device_node *dev_dn)
+{
+ struct pci_dev *tmp = NULL;
+ struct device_node *child_dn;
+
+ list_for_each_entry(tmp, &parent->devices, bus_list) {
+ child_dn = pci_device_to_OF_node(tmp);
+ if (child_dn == dev_dn)
+ return tmp;
+ }
+ return NULL;
+}
+
+static void dlpar_pci_add_bus(struct device_node *dn)
+{
+ struct pci_dn *pdn = PCI_DN(dn);
+ struct pci_controller *phb = pdn->phb;
+ struct pci_dev *dev = NULL;
+
+ pseries_eeh_init_edev_recursive(pdn);
+
+ /* Add EADS device to PHB bus, adding new entry to bus->devices */
+ dev = of_create_pci_dev(dn, phb->bus, pdn->devfn);
+ if (!dev) {
+ printk(KERN_ERR "%s: failed to create pci dev for %pOF\n",
+ __func__, dn);
+ return;
+ }
+
+ /* Scan below the new bridge */
+ if (pci_is_bridge(dev))
+ of_scan_pci_bridge(dev);
+
+ /* Map IO space for child bus, which may or may not succeed */
+ pcibios_map_io_space(dev->subordinate);
+
+ /* Finish adding it : resource allocation, adding devices, etc...
+ * Note that we need to perform the finish pass on the -parent-
+ * bus of the EADS bridge so the bridge device itself gets
+ * properly added
+ */
+ pcibios_finish_adding_to_bus(phb->bus);
+}
+
+static int dlpar_add_pci_slot(char *drc_name, struct device_node *dn)
+{
+ struct pci_dev *dev;
+ struct pci_controller *phb;
+
+ if (pci_find_bus_by_node(dn))
+ return -EINVAL;
+
+ /* Add pci bus */
+ dlpar_pci_add_bus(dn);
+
+ /* Confirm new bridge dev was created */
+ phb = PCI_DN(dn)->phb;
+ dev = dlpar_find_new_dev(phb->bus, dn);
+
+ if (!dev) {
+ printk(KERN_ERR "%s: unable to add bus %s\n", __func__,
+ drc_name);
+ return -EIO;
+ }
+
+ if (dev->hdr_type != PCI_HEADER_TYPE_BRIDGE) {
+ printk(KERN_ERR "%s: unexpected header type %d, unable to add bus %s\n",
+ __func__, dev->hdr_type, drc_name);
+ return -EIO;
+ }
+
+ /* Add hotplug slot */
+ if (rpaphp_add_slot(dn)) {
+ printk(KERN_ERR "%s: unable to add hotplug slot %s\n",
+ __func__, drc_name);
+ return -EIO;
+ }
+ return 0;
+}
+
+static int dlpar_remove_phb(char *drc_name, struct device_node *dn)
+{
+ struct slot *slot;
+ struct pci_dn *pdn;
+ int rc = 0;
+
+ if (!pci_find_bus_by_node(dn))
+ return -EINVAL;
+
+ /* If pci slot is hotpluggable, use hotplug to remove it */
+ slot = find_php_slot(dn);
+ if (slot && rpaphp_deregister_slot(slot)) {
+ printk(KERN_ERR "%s: unable to remove hotplug slot %s\n",
+ __func__, drc_name);
+ return -EIO;
+ }
+
+ pdn = dn->data;
+ BUG_ON(!pdn || !pdn->phb);
+ rc = remove_phb_dynamic(pdn->phb);
+ if (rc < 0)
+ return rc;
+
+ pdn->phb = NULL;
+
+ return 0;
+}
+
+static int dlpar_add_phb(char *drc_name, struct device_node *dn)
+{
+ struct pci_controller *phb;
+
+ if (PCI_DN(dn) && PCI_DN(dn)->phb) {
+ /* PHB already exists */
+ return -EINVAL;
+ }
+
+ phb = init_phb_dynamic(dn);
+ if (!phb)
+ return -EIO;
+
+ if (rpaphp_add_slot(dn)) {
+ printk(KERN_ERR "%s: unable to add hotplug slot %s\n",
+ __func__, drc_name);
+ return -EIO;
+ }
+ return 0;
+}
+
+static int dlpar_add_vio_slot(char *drc_name, struct device_node *dn)
+{
+ struct vio_dev *vio_dev;
+
+ vio_dev = vio_find_node(dn);
+ if (vio_dev) {
+ put_device(&vio_dev->dev);
+ return -EINVAL;
+ }
+
+ if (!vio_register_device_node(dn)) {
+ printk(KERN_ERR
+ "%s: failed to register vio node %s\n",
+ __func__, drc_name);
+ return -EIO;
+ }
+ return 0;
+}
+
+/**
+ * dlpar_add_slot - DLPAR add an I/O Slot
+ * @drc_name: drc-name of newly added slot
+ *
+ * Make the hotplug module and the kernel aware of a newly added I/O Slot.
+ * Return Codes:
+ * 0 Success
+ * -ENODEV Not a valid drc_name
+ * -EINVAL Slot already added
+ * -ERESTARTSYS Signalled before obtaining lock
+ * -EIO Internal PCI Error
+ */
+int dlpar_add_slot(char *drc_name)
+{
+ struct device_node *dn = NULL;
+ int node_type;
+ int rc = -EIO;
+
+ if (mutex_lock_interruptible(&rpadlpar_mutex))
+ return -ERESTARTSYS;
+
+ /* Find newly added node */
+ dn = find_dlpar_node(drc_name, &node_type);
+ if (!dn) {
+ rc = -ENODEV;
+ goto exit;
+ }
+
+ switch (node_type) {
+ case NODE_TYPE_VIO:
+ rc = dlpar_add_vio_slot(drc_name, dn);
+ break;
+ case NODE_TYPE_SLOT:
+ rc = dlpar_add_pci_slot(drc_name, dn);
+ break;
+ case NODE_TYPE_PHB:
+ rc = dlpar_add_phb(drc_name, dn);
+ break;
+ }
+ of_node_put(dn);
+
+ printk(KERN_INFO "%s: slot %s added\n", DLPAR_MODULE_NAME, drc_name);
+exit:
+ mutex_unlock(&rpadlpar_mutex);
+ return rc;
+}
+
+/**
+ * dlpar_remove_vio_slot - DLPAR remove a virtual I/O Slot
+ * @drc_name: drc-name of newly added slot
+ * @dn: &device_node
+ *
+ * Remove the kernel and hotplug representations of an I/O Slot.
+ * Return Codes:
+ * 0 Success
+ * -EINVAL Vio dev doesn't exist
+ */
+static int dlpar_remove_vio_slot(char *drc_name, struct device_node *dn)
+{
+ struct vio_dev *vio_dev;
+
+ vio_dev = vio_find_node(dn);
+ if (!vio_dev)
+ return -EINVAL;
+
+ vio_unregister_device(vio_dev);
+
+ put_device(&vio_dev->dev);
+
+ return 0;
+}
+
+/**
+ * dlpar_remove_pci_slot - DLPAR remove a PCI I/O Slot
+ * @drc_name: drc-name of newly added slot
+ * @dn: &device_node
+ *
+ * Remove the kernel and hotplug representations of a PCI I/O Slot.
+ * Return Codes:
+ * 0 Success
+ * -ENODEV Not a valid drc_name
+ * -EIO Internal PCI Error
+ */
+static int dlpar_remove_pci_slot(char *drc_name, struct device_node *dn)
+{
+ struct pci_bus *bus;
+ struct slot *slot;
+ int ret = 0;
+
+ pci_lock_rescan_remove();
+
+ bus = pci_find_bus_by_node(dn);
+ if (!bus) {
+ ret = -EINVAL;
+ goto out;
+ }
+
+ pr_debug("PCI: Removing PCI slot below EADS bridge %s\n",
+ bus->self ? pci_name(bus->self) : "<!PHB!>");
+
+ slot = find_php_slot(dn);
+ if (slot) {
+ pr_debug("PCI: Removing hotplug slot for %04x:%02x...\n",
+ pci_domain_nr(bus), bus->number);
+
+ if (rpaphp_deregister_slot(slot)) {
+ printk(KERN_ERR
+ "%s: unable to remove hotplug slot %s\n",
+ __func__, drc_name);
+ ret = -EIO;
+ goto out;
+ }
+ }
+
+ /* Remove all devices below slot */
+ pci_hp_remove_devices(bus);
+
+ /* Unmap PCI IO space */
+ if (pcibios_unmap_io_space(bus)) {
+ printk(KERN_ERR "%s: failed to unmap bus range\n",
+ __func__);
+ ret = -ERANGE;
+ goto out;
+ }
+
+ /* Remove the EADS bridge device itself */
+ BUG_ON(!bus->self);
+ pr_debug("PCI: Now removing bridge device %s\n", pci_name(bus->self));
+ pci_stop_and_remove_bus_device(bus->self);
+
+ out:
+ pci_unlock_rescan_remove();
+ return ret;
+}
+
+/**
+ * dlpar_remove_slot - DLPAR remove an I/O Slot
+ * @drc_name: drc-name of newly added slot
+ *
+ * Remove the kernel and hotplug representations of an I/O Slot.
+ * Return Codes:
+ * 0 Success
+ * -ENODEV Not a valid drc_name
+ * -EINVAL Slot already removed
+ * -ERESTARTSYS Signalled before obtaining lock
+ * -EIO Internal Error
+ */
+int dlpar_remove_slot(char *drc_name)
+{
+ struct device_node *dn;
+ int node_type;
+ int rc = 0;
+
+ if (mutex_lock_interruptible(&rpadlpar_mutex))
+ return -ERESTARTSYS;
+
+ dn = find_dlpar_node(drc_name, &node_type);
+ if (!dn) {
+ rc = -ENODEV;
+ goto exit;
+ }
+
+ switch (node_type) {
+ case NODE_TYPE_VIO:
+ rc = dlpar_remove_vio_slot(drc_name, dn);
+ break;
+ case NODE_TYPE_PHB:
+ rc = dlpar_remove_phb(drc_name, dn);
+ break;
+ case NODE_TYPE_SLOT:
+ rc = dlpar_remove_pci_slot(drc_name, dn);
+ break;
+ }
+ of_node_put(dn);
+ vm_unmap_aliases();
+
+ printk(KERN_INFO "%s: slot %s removed\n", DLPAR_MODULE_NAME, drc_name);
+exit:
+ mutex_unlock(&rpadlpar_mutex);
+ return rc;
+}
+
+static inline int is_dlpar_capable(void)
+{
+ int rc = rtas_token("ibm,configure-connector");
+
+ return (int) (rc != RTAS_UNKNOWN_SERVICE);
+}
+
+static int __init rpadlpar_io_init(void)
+{
+
+ if (!is_dlpar_capable()) {
+ printk(KERN_WARNING "%s: partition not DLPAR capable\n",
+ __func__);
+ return -EPERM;
+ }
+
+ return dlpar_sysfs_init();
+}
+
+static void __exit rpadlpar_io_exit(void)
+{
+ dlpar_sysfs_exit();
+}
+
+module_init(rpadlpar_io_init);
+module_exit(rpadlpar_io_exit);
+MODULE_LICENSE("GPL");