/* * Device Tree Source for OMAP4/5 SoC CPU thermal * * Copyright (C) 2013 Texas Instruments Incorporated - https://www.ti.com/ * Contact: Eduardo Valentin * * This file is licensed under the terms of the GNU General Public License * version 2. This program is licensed "as is" without any warranty of any * kind, whether express or implied. */ #include cpu_thermal: cpu_thermal { polling-delay-passive = <250>; /* milliseconds */ polling-delay = <1000>; /* milliseconds */ /* * See 44xx files for single sensor addressing, omap5 and dra7 need * also sensor ID for addressing. */ thermal-sensors = <&bandgap 0>; cpu_trips: trips { cpu_alert0: cpu_alert { temperature = <100000>; /* millicelsius */ hysteresis = <2000>; /* millicelsius */ type = "passive"; }; cpu_crit: cpu_crit { temperature = <125000>; /* millicelsius */ hysteresis = <2000>; /* millicelsius */ type = "critical"; }; }; cpu_cooling_maps: cooling-maps { map0 { trip = <&cpu_alert0>; cooling-device = <&cpu0 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>; }; }; };