// SPDX-License-Identifier: GPL-2.0
/*
* Device tree sources for Exynos4 thermal zone
*
* Copyright (c) 2014 Lukasz Majewski <l.majewski@samsung.com>
*/
#include <dt-bindings/thermal/thermal.h>
/ {
thermal-zones {
cpu_thermal: cpu-thermal {
thermal-sensors = <&tmu>;
polling-delay-passive = <0>;
polling-delay = <0>;
trips {
cpu_alert0: cpu-alert-0 {
temperature = <70000>; /* millicelsius */
hysteresis = <10000>; /* millicelsius */
type = "active";
};
cpu_alert1: cpu-alert-1 {
temperature = <95000>; /* millicelsius */
hysteresis = <10000>; /* millicelsius */
type = "active";
};
cpu_alert2: cpu-alert-2 {
temperature = <110000>; /* millicelsius */
hysteresis = <10000>; /* millicelsius */
type = "active";
};
cpu_crit0: cpu-crit-0 {
temperature = <120000>; /* millicelsius */
hysteresis = <0>; /* millicelsius */
type = "critical";
};
};
cooling-maps {
map0 {
trip = <&cpu_alert0>;
};
map1 {
trip = <&cpu_alert1>;
};
};
};
};
};
|