+title: "Linux machine sensors monitoring with Netdata"
+custom_edit_url: https://github.com/netdata/netdata/edit/master/collectors/charts.d.plugin/sensors/README.md
+-->
+
+# Linux machine sensors monitoring with Netdata
+
+> THIS MODULE IS OBSOLETE.
+> USE [THE PYTHON ONE](/collectors/python.d.plugin/sensors) - IT SUPPORTS MULTIPLE JOBS AND IT IS MORE EFFICIENT
+>
+> Unlike the python one, this module can collect temperature on RPi.
+
+The plugin will provide charts for all configured system sensors
+
+> This plugin is reading sensors directly from the kernel.
+> The `lm-sensors` package is able to perform calculations on the
+> kernel provided values, this plugin will not perform.
+> So, the values graphed, are the raw hardware values of the sensors.
+
+The plugin will create Netdata charts for:
+
+1. **Temperature**
+2. **Voltage**
+3. **Current**
+4. **Power**
+5. **Fans Speed**
+6. **Energy**
+7. **Humidity**
+
+One chart for every sensor chip found and each of the above will be created.
+
+## Configuration
+
+Edit the `charts.d/sensors.conf` configuration file using `edit-config` from the Netdata [config
+directory](/docs/configure/nodes.md), which is typically at `/etc/netdata`.
+
+```bash
+cd /etc/netdata # Replace this path with your Netdata config directory, if different
+sudo ./edit-config charts.d/sensors.conf
+```
+
+This is the internal default for `charts.d/sensors.conf`
+
+```sh
+# the directory the kernel keeps sensor data
+sensors_sys_dir="${NETDATA_HOST_PREFIX}/sys/devices"
+
+# how deep in the tree to check for sensor data
+sensors_sys_depth=10
+
+# if set to 1, the script will overwrite internal
+# script functions with code generated ones
+# leave to 1, is faster
+sensors_source_update=1
+
+# how frequently to collect sensor data
+# the default is to collect it at every iteration of charts.d
+sensors_update_every=
+
+# array of sensors which are excluded
+# the default is to include all
+sensors_excluded=()
+```
+
+---
+
+[![analytics](https://www.google-analytics.com/collect?v=1&aip=1&t=pageview&_s=1&ds=github&dr=https%3A%2F%2Fgithub.com%2Fnetdata%2Fnetdata&dl=https%3A%2F%2Fmy-netdata.io%2Fgithub%2Fcollectors%2Fcharts.d.plugin%2Fsensors%2FREADME&_u=MAC~&cid=5792dfd7-8dc4-476b-af31-da2fdb9f93d2&tid=UA-64295674-3)](<>)