summaryrefslogtreecommitdiffstats
path: root/man/sd_bus_start.xml
diff options
context:
space:
mode:
authorDaniel Baumann <daniel.baumann@progress-linux.org>2024-04-27 13:00:47 +0000
committerDaniel Baumann <daniel.baumann@progress-linux.org>2024-04-27 13:00:47 +0000
commit2cb7e0aaedad73b076ea18c6900b0e86c5760d79 (patch)
treeda68ca54bb79f4080079bf0828acda937593a4e1 /man/sd_bus_start.xml
parentInitial commit. (diff)
downloadsystemd-2cb7e0aaedad73b076ea18c6900b0e86c5760d79.tar.xz
systemd-2cb7e0aaedad73b076ea18c6900b0e86c5760d79.zip
Adding upstream version 247.3.upstream/247.3upstream
Signed-off-by: Daniel Baumann <daniel.baumann@progress-linux.org>
Diffstat (limited to 'man/sd_bus_start.xml')
-rw-r--r--man/sd_bus_start.xml124
1 files changed, 124 insertions, 0 deletions
diff --git a/man/sd_bus_start.xml b/man/sd_bus_start.xml
new file mode 100644
index 0000000..68fe3e0
--- /dev/null
+++ b/man/sd_bus_start.xml
@@ -0,0 +1,124 @@
+<?xml version='1.0'?>
+<!DOCTYPE refentry PUBLIC "-//OASIS//DTD DocBook XML V4.5//EN"
+ "http://www.oasis-open.org/docbook/xml/4.2/docbookx.dtd">
+<!-- SPDX-License-Identifier: LGPL-2.1-or-later -->
+
+<refentry id="sd_bus_start"
+ xmlns:xi="http://www.w3.org/2001/XInclude">
+
+ <refentryinfo>
+ <title>sd_bus_start</title>
+ <productname>systemd</productname>
+ </refentryinfo>
+
+ <refmeta>
+ <refentrytitle>sd_bus_start</refentrytitle>
+ <manvolnum>3</manvolnum>
+ </refmeta>
+
+ <refnamediv>
+ <refname>sd_bus_start</refname>
+
+ <refpurpose>Initiate a bus connection to the D-bus broker daemon
+ </refpurpose>
+ </refnamediv>
+
+ <refsynopsisdiv>
+ <funcsynopsis>
+ <funcsynopsisinfo>#include &lt;systemd/sd-bus.h&gt;</funcsynopsisinfo>
+
+ <funcprototype>
+ <funcdef>int <function>sd_bus_start</function></funcdef>
+ <paramdef>sd_bus *<parameter>bus</parameter></paramdef>
+ </funcprototype>
+ </funcsynopsis>
+ </refsynopsisdiv>
+
+ <refsect1>
+ <title>Description</title>
+
+ <para><function>sd_bus_start()</function> connects an existing bus connection object to the D-Bus
+ broker daemon, usually
+ <citerefentry project='die-net'><refentrytitle>dbus-daemon</refentrytitle><manvolnum>1</manvolnum></citerefentry>
+ or
+ <citerefentry project='mankier'><refentrytitle>dbus-broker</refentrytitle><manvolnum>1</manvolnum></citerefentry>.
+ The mechanism to use for the connection must be configured before the call to
+ <function>sd_bus_start()</function>, using one of
+ <citerefentry><refentrytitle>sd_bus_set_address</refentrytitle><manvolnum>3</manvolnum></citerefentry>,
+ <citerefentry><refentrytitle>sd_bus_set_fd</refentrytitle><manvolnum>3</manvolnum></citerefentry>, or
+ <citerefentry><refentrytitle>sd_bus_set_exec</refentrytitle><manvolnum>3</manvolnum></citerefentry>.
+ <function>sd_bus_start()</function> will open the connection socket or spawn the executable as
+ needed, and asynchronously start a <function>org.freedesktop.DBus.Hello()</function> call. The
+ answer to the Hello call will be processed later from
+ <citerefentry><refentrytitle>sd_bus_process</refentrytitle><manvolnum>3</manvolnum></citerefentry>. If
+ opening of the connection or queuing of the asynchronous call fail, the connection will be closed with
+ <citerefentry><refentrytitle>sd_bus_close</refentrytitle><manvolnum>3</manvolnum></citerefentry>.</para>
+
+ <para>In most cases, it is better to use
+ <citerefentry><refentrytitle>sd_bus_default_user</refentrytitle><manvolnum>3</manvolnum></citerefentry>,
+ <citerefentry><refentrytitle>sd_bus_default_system</refentrytitle><manvolnum>3</manvolnum></citerefentry>
+ or related calls instead of the more low-level <function>sd_bus_new()</function> and
+ <function>sd_bus_start()</function>. The higher-level functions not only allocate a bus object but also
+ start the connection to a well-known bus in a single function call.</para>
+ </refsect1>
+
+ <refsect1>
+ <title>Return Value</title>
+
+ <para>On success, this function returns a non-negative integer. On failure, it returns a negative
+ errno-style error code.</para>
+
+ <refsect2 id='errors'>
+ <title>Errors</title>
+
+ <variablelist>
+ <varlistentry>
+ <term><constant>-EINVAL</constant></term>
+
+ <listitem><para>The input parameter <parameter>bus</parameter> is <constant>NULL</constant>.
+ </para></listitem>
+ </varlistentry>
+
+ <varlistentry>
+ <term><constant>-ENOPKG</constant></term>
+
+ <listitem><para>Bus object <parameter>bus</parameter> could not be resolved.</para>
+ </listitem>
+ </varlistentry>
+
+ <varlistentry>
+ <term><constant>-EPERM</constant></term>
+
+ <listitem><para>The input parameter <parameter>bus</parameter> is in a wrong state
+ (<function>sd_bus_start()</function> may only be called once on a newly-created bus object).</para>
+ </listitem>
+ </varlistentry>
+
+ <varlistentry>
+ <term><constant>-ECHILD</constant></term>
+
+ <listitem><para>The bus object <parameter>bus</parameter> was created in a different
+ process.</para>
+ </listitem>
+ </varlistentry>
+ </variablelist>
+
+ <para>In addition, other connection-related errors may be returned. See
+ <citerefentry><refentrytitle>sd_bus_send</refentrytitle><manvolnum>3</manvolnum></citerefentry>.</para>
+ </refsect2>
+ </refsect1>
+
+ <xi:include href="libsystemd-pkgconfig.xml" />
+
+ <refsect1>
+ <title>See Also</title>
+
+ <para>
+ <citerefentry><refentrytitle>systemd</refentrytitle><manvolnum>1</manvolnum></citerefentry>,
+ <citerefentry><refentrytitle>sd-bus</refentrytitle><manvolnum>3</manvolnum></citerefentry>,
+ <citerefentry><refentrytitle>sd_bus_default</refentrytitle><manvolnum>3</manvolnum></citerefentry>,
+ <citerefentry><refentrytitle>sd_bus_call_async</refentrytitle><manvolnum>3</manvolnum></citerefentry>
+ </para>
+ </refsect1>
+
+</refentry>