summaryrefslogtreecommitdiffstats
path: root/doc/hardware-monitoring/index.rst
diff options
context:
space:
mode:
Diffstat (limited to '')
-rw-r--r--doc/hardware-monitoring/index.rst183
1 files changed, 183 insertions, 0 deletions
diff --git a/doc/hardware-monitoring/index.rst b/doc/hardware-monitoring/index.rst
new file mode 100644
index 000000000..dcafa8230
--- /dev/null
+++ b/doc/hardware-monitoring/index.rst
@@ -0,0 +1,183 @@
+.. _hardware-monitoring:
+
+Hardware monitoring
+===================
+
+`node-proxy` is the internal name to designate the running agent which inventories a machine's hardware, provides the different statuses and enable the operator to perform some actions.
+It gathers details from the RedFish API, processes and pushes data to agent endpoint in the Ceph manager daemon.
+
+.. graphviz::
+
+ digraph G {
+ node [shape=record];
+ mgr [label="{<mgr> ceph manager}"];
+ dashboard [label="<dashboard> ceph dashboard"];
+ agent [label="<agent> agent"];
+ redfish [label="<redfish> redfish"];
+
+ agent -> redfish [label=" 1." color=green];
+ agent -> mgr [label=" 2." color=orange];
+ dashboard:dashboard -> mgr [label=" 3."color=lightgreen];
+ node [shape=plaintext];
+ legend [label=<<table border="0" cellborder="1" cellspacing="0">
+ <tr><td bgcolor="lightgrey">Legend</td></tr>
+ <tr><td align="center">1. Collects data from redfish API</td></tr>
+ <tr><td align="left">2. Pushes data to ceph mgr</td></tr>
+ <tr><td align="left">3. Query ceph mgr</td></tr>
+ </table>>];
+ }
+
+
+Limitations
+-----------
+
+For the time being, the `node-proxy` agent relies on the RedFish API.
+It implies both `node-proxy` agent and `ceph-mgr` daemon need to be able to access the Out-Of-Band network to work.
+
+
+Deploying the agent
+-------------------
+
+| The first step is to provide the out of band management tool credentials.
+| This can be done when adding the host with a service spec file:
+
+.. code-block:: bash
+
+ # cat host.yml
+ ---
+ service_type: host
+ hostname: node-10
+ addr: 10.10.10.10
+ oob:
+ addr: 20.20.20.10
+ username: admin
+ password: p@ssword
+
+Apply the spec:
+
+.. code-block:: bash
+
+ # ceph orch apply -i host.yml
+ Added host 'node-10' with addr '10.10.10.10'
+
+Deploy the agent:
+
+.. code-block:: bash
+
+ # ceph config set mgr mgr/cephadm/hw_monitoring true
+
+CLI
+---
+
+| **orch** **hardware** **status** [hostname] [--category CATEGORY] [--format plain | json]
+
+supported categories are:
+
+* summary (default)
+* memory
+* storage
+* processors
+* network
+* power
+* fans
+* firmwares
+* criticals
+
+Examples
+********
+
+
+hardware health statuses summary
+++++++++++++++++++++++++++++++++
+
+.. code-block:: bash
+
+ # ceph orch hardware status
+ +------------+---------+-----+-----+--------+-------+------+
+ | HOST | STORAGE | CPU | NET | MEMORY | POWER | FANS |
+ +------------+---------+-----+-----+--------+-------+------+
+ | node-10 | ok | ok | ok | ok | ok | ok |
+ +------------+---------+-----+-----+--------+-------+------+
+
+
+storage devices report
+++++++++++++++++++++++
+
+.. code-block:: bash
+
+ # ceph orch hardware status IBM-Ceph-1 --category storage
+ +------------+--------------------------------------------------------+------------------+----------------+----------+----------------+--------+---------+
+ | HOST | NAME | MODEL | SIZE | PROTOCOL | SN | STATUS | STATE |
+ +------------+--------------------------------------------------------+------------------+----------------+----------+----------------+--------+---------+
+ | node-10 | Disk 8 in Backplane 1 of Storage Controller in Slot 2 | ST20000NM008D-3D | 20000588955136 | SATA | ZVT99QLL | OK | Enabled |
+ | node-10 | Disk 10 in Backplane 1 of Storage Controller in Slot 2 | ST20000NM008D-3D | 20000588955136 | SATA | ZVT98ZYX | OK | Enabled |
+ | node-10 | Disk 11 in Backplane 1 of Storage Controller in Slot 2 | ST20000NM008D-3D | 20000588955136 | SATA | ZVT98ZWB | OK | Enabled |
+ | node-10 | Disk 9 in Backplane 1 of Storage Controller in Slot 2 | ST20000NM008D-3D | 20000588955136 | SATA | ZVT98ZC9 | OK | Enabled |
+ | node-10 | Disk 3 in Backplane 1 of Storage Controller in Slot 2 | ST20000NM008D-3D | 20000588955136 | SATA | ZVT9903Y | OK | Enabled |
+ | node-10 | Disk 1 in Backplane 1 of Storage Controller in Slot 2 | ST20000NM008D-3D | 20000588955136 | SATA | ZVT9901E | OK | Enabled |
+ | node-10 | Disk 7 in Backplane 1 of Storage Controller in Slot 2 | ST20000NM008D-3D | 20000588955136 | SATA | ZVT98ZQJ | OK | Enabled |
+ | node-10 | Disk 2 in Backplane 1 of Storage Controller in Slot 2 | ST20000NM008D-3D | 20000588955136 | SATA | ZVT99PA2 | OK | Enabled |
+ | node-10 | Disk 4 in Backplane 1 of Storage Controller in Slot 2 | ST20000NM008D-3D | 20000588955136 | SATA | ZVT99PFG | OK | Enabled |
+ | node-10 | Disk 0 in Backplane 0 of Storage Controller in Slot 2 | MZ7L33T8HBNAAD3 | 3840755981824 | SATA | S6M5NE0T800539 | OK | Enabled |
+ | node-10 | Disk 1 in Backplane 0 of Storage Controller in Slot 2 | MZ7L33T8HBNAAD3 | 3840755981824 | SATA | S6M5NE0T800554 | OK | Enabled |
+ | node-10 | Disk 6 in Backplane 1 of Storage Controller in Slot 2 | ST20000NM008D-3D | 20000588955136 | SATA | ZVT98ZER | OK | Enabled |
+ | node-10 | Disk 0 in Backplane 1 of Storage Controller in Slot 2 | ST20000NM008D-3D | 20000588955136 | SATA | ZVT98ZEJ | OK | Enabled |
+ | node-10 | Disk 5 in Backplane 1 of Storage Controller in Slot 2 | ST20000NM008D-3D | 20000588955136 | SATA | ZVT99QMH | OK | Enabled |
+ | node-10 | Disk 0 on AHCI Controller in SL 6 | MTFDDAV240TDU | 240057409536 | SATA | 22373BB1E0F8 | OK | Enabled |
+ | node-10 | Disk 1 on AHCI Controller in SL 6 | MTFDDAV240TDU | 240057409536 | SATA | 22373BB1E0D5 | OK | Enabled |
+ +------------+--------------------------------------------------------+------------------+----------------+----------+----------------+--------+---------+
+
+
+
+firmwares details
++++++++++++++++++
+
+.. code-block:: bash
+
+ # ceph orch hardware status node-10 --category firmwares
+ +------------+----------------------------------------------------------------------------+--------------------------------------------------------------+----------------------+-------------+--------+
+ | HOST | COMPONENT | NAME | DATE | VERSION | STATUS |
+ +------------+----------------------------------------------------------------------------+--------------------------------------------------------------+----------------------+-------------+--------+
+ | node-10 | current-107649-7.03__raid.backplane.firmware.0 | Backplane 0 | 2022-12-05T00:00:00Z | 7.03 | OK |
+
+
+ ... omitted output ...
+
+
+ | node-10 | previous-25227-6.10.30.20__idrac.embedded.1-1 | Integrated Remote Access Controller | 00:00:00Z | 6.10.30.20 | OK |
+ +------------+----------------------------------------------------------------------------+--------------------------------------------------------------+----------------------+-------------+--------+
+
+
+hardware critical warnings report
++++++++++++++++++++++++++++++++++
+
+.. code-block:: bash
+
+ # ceph orch hardware status --category criticals
+ +------------+-----------+------------+----------+-----------------+
+ | HOST | COMPONENT | NAME | STATUS | STATE |
+ +------------+-----------+------------+----------+-----------------+
+ | node-10 | power | PS2 Status | critical | unplugged |
+ +------------+-----------+------------+----------+-----------------+
+
+
+Developpers
+-----------
+
+.. py:currentmodule:: cephadm.agent
+.. autoclass:: NodeProxyEndpoint
+.. automethod:: NodeProxyEndpoint.__init__
+.. automethod:: NodeProxyEndpoint.oob
+.. automethod:: NodeProxyEndpoint.data
+.. automethod:: NodeProxyEndpoint.fullreport
+.. automethod:: NodeProxyEndpoint.summary
+.. automethod:: NodeProxyEndpoint.criticals
+.. automethod:: NodeProxyEndpoint.memory
+.. automethod:: NodeProxyEndpoint.storage
+.. automethod:: NodeProxyEndpoint.network
+.. automethod:: NodeProxyEndpoint.power
+.. automethod:: NodeProxyEndpoint.processors
+.. automethod:: NodeProxyEndpoint.fans
+.. automethod:: NodeProxyEndpoint.firmwares
+.. automethod:: NodeProxyEndpoint.led
+