+ OSD Config Reference
+======================
+
+.. index:: OSD; configuration
+
+You can configure Ceph OSD Daemons in the Ceph configuration file (or in recent
+releases, the central config store), but Ceph OSD
+Daemons can use the default values and a very minimal configuration. A minimal
+Ceph OSD Daemon configuration sets ``host`` and
+uses default values for nearly everything else.
+
+Ceph OSD Daemons are numerically identified in incremental fashion, beginning
+with ``0`` using the following convention. ::
+
+ osd.0
+ osd.1
+ osd.2
+
+In a configuration file, you may specify settings for all Ceph OSD Daemons in
+the cluster by adding configuration settings to the ``[osd]`` section of your
+configuration file. To add settings directly to a specific Ceph OSD Daemon
+(e.g., ``host``), enter it in an OSD-specific section of your configuration
+file. For example:
+
+.. code-block:: ini
+
+ [osd]
+ osd_journal_size = 5120
+
+ [osd.0]
+ host = osd-host-a
+
+ [osd.1]
+ host = osd-host-b
+
+
+.. index:: OSD; config settings
+
+General Settings
+================
+
+The following settings provide a Ceph OSD Daemon's ID, and determine paths to
+data and journals. Ceph deployment scripts typically generate the UUID
+automatically.
+
+.. warning:: **DO NOT** change the default paths for data or journals, as it
+ makes it more problematic to troubleshoot Ceph later.
+
+When using Filestore, the journal size should be at least twice the product of the expected drive
+speed multiplied by ``filestore_max_sync_interval``. However, the most common
+practice is to partition the journal drive (often an SSD), and mount it such
+that Ceph uses the entire partition for the journal.
+
+.. confval:: osd_uuid
+.. confval:: osd_data
+.. confval:: osd_max_write_size
+.. confval:: osd_max_object_size
+.. confval:: osd_client_message_size_cap
+.. confval:: osd_class_dir
+ :default: $libdir/rados-classes
+
+.. index:: OSD; file system
+
+File System Settings
+====================
+Ceph builds and mounts file systems which are used for Ceph OSDs.
+
+``osd_mkfs_options {fs-type}``
+
+:Description: Options used when creating a new Ceph Filestore OSD of type {fs-type}.
+
+:Type: String
+:Default for xfs: ``-f -i 2048``
+:Default for other file systems: {empty string}
+
+For example::
+ ``osd_mkfs_options_xfs = -f -d agcount=24``
+
+``osd_mount_options {fs-type}``
+
+:Description: Options used when mounting a Ceph Filestore OSD of type {fs-type}.
+
+:Type: String
+:Default for xfs: ``rw,noatime,inode64``
+:Default for other file systems: ``rw, noatime``
+
+For example::
+ ``osd_mount_options_xfs = rw, noatime, inode64, logbufs=8``
+
+
+.. index:: OSD; journal settings
+
+Journal Settings
+================
+
+This section applies only to the older Filestore OSD back end. Since Luminous
+BlueStore has been default and preferred.
+
+By default, Ceph expects that you will provision a Ceph OSD Daemon's journal at
+the following path, which is usually a symlink to a device or partition::
+
+ /var/lib/ceph/osd/$cluster-$id/journal
+
+When using a single device type (for example, spinning drives), the journals
+should be *colocated*: the logical volume (or partition) should be in the same
+device as the ``data`` logical volume.
+
+When using a mix of fast (SSDs, NVMe) devices with slower ones (like spinning
+drives) it makes sense to place the journal on the faster device, while
+``data`` occupies the slower device fully.
+
+The default ``osd_journal_size`` value is 5120 (5 gigabytes), but it can be
+larger, in which case it will need to be set in the ``ceph.conf`` file.
+A value of 10 gigabytes is common in practice::
+
+ osd_journal_size = 10240
+
+
+.. confval:: osd_journal
+.. confval:: osd_journal_size
+
+See `Journal Config Reference`_ for additional details.
+
+
+Monitor OSD Interaction
+=======================
+
+Ceph OSD Daemons check each other's heartbeats and report to monitors
+periodically. Ceph can use default values in many cases. However, if your
+network has latency issues, you may need to adopt longer intervals. See
+`Configuring Monitor/OSD Interaction`_ for a detailed discussion of heartbeats.
+
+
+Data Placement
+==============
+
+See `Pool & PG Config Reference`_ for details.
+
+
+.. index:: OSD; scrubbing
+
+.. _rados_config_scrubbing:
+
+Scrubbing
+=========
+
+One way that Ceph ensures data integrity is by "scrubbing" placement groups.
+Ceph scrubbing is analogous to ``fsck`` on the object storage layer. Ceph
+generates a catalog of all objects in each placement group and compares each
+primary object to its replicas, ensuring that no objects are missing or
+mismatched. Light scrubbing checks the object size and attributes, and is
+usually done daily. Deep scrubbing reads the data and uses checksums to ensure
+data integrity, and is usually done weekly. The freqeuncies of both light
+scrubbing and deep scrubbing are determined by the cluster's configuration,
+which is fully under your control and subject to the settings explained below
+in this section.
+
+Although scrubbing is important for maintaining data integrity, it can reduce
+the performance of the Ceph cluster. You can adjust the following settings to
+increase or decrease the frequency and depth of scrubbing operations.
+
+
+.. confval:: osd_max_scrubs
+.. confval:: osd_scrub_begin_hour
+.. confval:: osd_scrub_end_hour
+.. confval:: osd_scrub_begin_week_day
+.. confval:: osd_scrub_end_week_day
+.. confval:: osd_scrub_during_recovery
+.. confval:: osd_scrub_load_threshold
+.. confval:: osd_scrub_min_interval
+.. confval:: osd_scrub_max_interval
+.. confval:: osd_scrub_chunk_min
+.. confval:: osd_scrub_chunk_max
+.. confval:: osd_scrub_sleep
+.. confval:: osd_deep_scrub_interval
+.. confval:: osd_scrub_interval_randomize_ratio
+.. confval:: osd_deep_scrub_stride
+.. confval:: osd_scrub_auto_repair
+.. confval:: osd_scrub_auto_repair_num_errors
+
+.. index:: OSD; operations settings
+
+Operations
+==========
+
+.. confval:: osd_op_num_shards
+.. confval:: osd_op_num_shards_hdd
+.. confval:: osd_op_num_shards_ssd
+.. confval:: osd_op_queue
+.. confval:: osd_op_queue_cut_off
+.. confval:: osd_client_op_priority
+.. confval:: osd_recovery_op_priority
+.. confval:: osd_scrub_priority
+.. confval:: osd_requested_scrub_priority
+.. confval:: osd_snap_trim_priority
+.. confval:: osd_snap_trim_sleep
+.. confval:: osd_snap_trim_sleep_hdd
+.. confval:: osd_snap_trim_sleep_ssd
+.. confval:: osd_snap_trim_sleep_hybrid
+.. confval:: osd_op_thread_timeout
+.. confval:: osd_op_complaint_time
+.. confval:: osd_op_history_size
+.. confval:: osd_op_history_duration
+.. confval:: osd_op_log_threshold
+.. confval:: osd_op_thread_suicide_timeout
+.. note:: See https://old.ceph.com/planet/dealing-with-some-osd-timeouts/ for
+ more on ``osd_op_thread_suicide_timeout``. Be aware that this is a link to a
+ reworking of a blog post from 2017, and that its conclusion will direct you
+ back to this page "for more information".
+
+.. _dmclock-qos:
+
+QoS Based on mClock
+-------------------
+
+Ceph's use of mClock is now more refined and can be used by following the
+steps as described in `mClock Config Reference`_.
+
+Core Concepts
+`````````````
+
+Ceph's QoS support is implemented using a queueing scheduler
+based on `the dmClock algorithm`_. This algorithm allocates the I/O
+resources of the Ceph cluster in proportion to weights, and enforces
+the constraints of minimum reservation and maximum limitation, so that
+the services can compete for the resources fairly. Currently the
+*mclock_scheduler* operation queue divides Ceph services involving I/O
+resources into following buckets:
+
+- client op: the iops issued by client
+- osd subop: the iops issued by primary OSD
+- snap trim: the snap trimming related requests
+- pg recovery: the recovery related requests
+- pg scrub: the scrub related requests
+
+And the resources are partitioned using following three sets of tags. In other
+words, the share of each type of service is controlled by three tags:
+
+#. reservation: the minimum IOPS allocated for the service.
+#. limitation: the maximum IOPS allocated for the service.
+#. weight: the proportional share of capacity if extra capacity or system
+ oversubscribed.
+
+In Ceph, operations are graded with "cost". And the resources allocated
+for serving various services are consumed by these "costs". So, for
+example, the more reservation a services has, the more resource it is
+guaranteed to possess, as long as it requires. Assuming there are 2
+services: recovery and client ops:
+
+- recovery: (r:1, l:5, w:1)
+- client ops: (r:2, l:0, w:9)
+
+The settings above ensure that the recovery won't get more than 5
+requests per second serviced, even if it requires so (see CURRENT
+IMPLEMENTATION NOTE below), and no other services are competing with
+it. But if the clients start to issue large amount of I/O requests,
+neither will they exhaust all the I/O resources. 1 request per second
+is always allocated for recovery jobs as long as there are any such
+requests. So the recovery jobs won't be starved even in a cluster with
+high load. And in the meantime, the client ops can enjoy a larger
+portion of the I/O resource, because its weight is "9", while its
+competitor "1". In the case of client ops, it is not clamped by the
+limit setting, so it can make use of all the resources if there is no
+recovery ongoing.
+
+CURRENT IMPLEMENTATION NOTE: the current implementation enforces the limit
+values. Therefore, if a service crosses the enforced limit, the op remains
+in the operation queue until the limit is restored.
+
+Subtleties of mClock
+````````````````````
+
+The reservation and limit values have a unit of requests per
+second. The weight, however, does not technically have a unit and the
+weights are relative to one another. So if one class of requests has a
+weight of 1 and another a weight of 9, then the latter class of
+requests should get 9 executed at a 9 to 1 ratio as the first class.
+However that will only happen once the reservations are met and those
+values include the operations executed under the reservation phase.
+
+Even though the weights do not have units, one must be careful in
+choosing their values due how the algorithm assigns weight tags to
+requests. If the weight is *W*, then for a given class of requests,
+the next one that comes in will have a weight tag of *1/W* plus the
+previous weight tag or the current time, whichever is larger. That
+means if *W* is sufficiently large and therefore *1/W* is sufficiently
+small, the calculated tag may never be assigned as it will get a value
+of the current time. The ultimate lesson is that values for weight
+should not be too large. They should be under the number of requests
+one expects to be serviced each second.
+
+Caveats
+```````
+
+There are some factors that can reduce the impact of the mClock op
+queues within Ceph. First, requests to an OSD are sharded by their
+placement group identifier. Each shard has its own mClock queue and
+these queues neither interact nor share information among them. The
+number of shards can be controlled with the configuration options
+:confval:`osd_op_num_shards`, :confval:`osd_op_num_shards_hdd`, and
+:confval:`osd_op_num_shards_ssd`. A lower number of shards will increase the
+impact of the mClock queues, but may have other deleterious effects.
+
+Second, requests are transferred from the operation queue to the
+operation sequencer, in which they go through the phases of
+execution. The operation queue is where mClock resides and mClock
+determines the next op to transfer to the operation sequencer. The
+number of operations allowed in the operation sequencer is a complex
+issue. In general we want to keep enough operations in the sequencer
+so it's always getting work done on some operations while it's waiting
+for disk and network access to complete on other operations. On the
+other hand, once an operation is transferred to the operation
+sequencer, mClock no longer has control over it. Therefore to maximize
+the impact of mClock, we want to keep as few operations in the
+operation sequencer as possible. So we have an inherent tension.
+
+The configuration options that influence the number of operations in
+the operation sequencer are :confval:`bluestore_throttle_bytes`,
+:confval:`bluestore_throttle_deferred_bytes`,
+:confval:`bluestore_throttle_cost_per_io`,
+:confval:`bluestore_throttle_cost_per_io_hdd`, and
+:confval:`bluestore_throttle_cost_per_io_ssd`.
+
+A third factor that affects the impact of the mClock algorithm is that
+we're using a distributed system, where requests are made to multiple
+OSDs and each OSD has (can have) multiple shards. Yet we're currently
+using the mClock algorithm, which is not distributed (note: dmClock is
+the distributed version of mClock).
+
+Various organizations and individuals are currently experimenting with
+mClock as it exists in this code base along with their modifications
+to the code base. We hope you'll share you're experiences with your
+mClock and dmClock experiments on the ``ceph-devel`` mailing list.
+
+.. confval:: osd_async_recovery_min_cost
+.. confval:: osd_push_per_object_cost
+.. confval:: osd_mclock_scheduler_client_res
+.. confval:: osd_mclock_scheduler_client_wgt
+.. confval:: osd_mclock_scheduler_client_lim
+.. confval:: osd_mclock_scheduler_background_recovery_res
+.. confval:: osd_mclock_scheduler_background_recovery_wgt
+.. confval:: osd_mclock_scheduler_background_recovery_lim
+.. confval:: osd_mclock_scheduler_background_best_effort_res
+.. confval:: osd_mclock_scheduler_background_best_effort_wgt
+.. confval:: osd_mclock_scheduler_background_best_effort_lim
+
+.. _the dmClock algorithm: https://www.usenix.org/legacy/event/osdi10/tech/full_papers/Gulati.pdf
+
+.. index:: OSD; backfilling
+
+Backfilling
+===========
+
+When you add or remove Ceph OSD Daemons to a cluster, CRUSH will
+rebalance the cluster by moving placement groups to or from Ceph OSDs
+to restore balanced utilization. The process of migrating placement groups and
+the objects they contain can reduce the cluster's operational performance
+considerably. To maintain operational performance, Ceph performs this migration
+with 'backfilling', which allows Ceph to set backfill operations to a lower
+priority than requests to read or write data.
+
+
+.. confval:: osd_max_backfills
+.. confval:: osd_backfill_scan_min
+.. confval:: osd_backfill_scan_max
+.. confval:: osd_backfill_retry_interval
+
+.. index:: OSD; osdmap
+
+OSD Map
+=======
+
+OSD maps reflect the OSD daemons operating in the cluster. Over time, the
+number of map epochs increases. Ceph provides some settings to ensure that
+Ceph performs well as the OSD map grows larger.
+
+.. confval:: osd_map_dedup
+.. confval:: osd_map_cache_size
+.. confval:: osd_map_message_max
+
+.. index:: OSD; recovery
+
+Recovery
+========
+
+When the cluster starts or when a Ceph OSD Daemon crashes and restarts, the OSD
+begins peering with other Ceph OSD Daemons before writes can occur. See
+`Monitoring OSDs and PGs`_ for details.
+
+If a Ceph OSD Daemon crashes and comes back online, usually it will be out of
+sync with other Ceph OSD Daemons containing more recent versions of objects in
+the placement groups. When this happens, the Ceph OSD Daemon goes into recovery
+mode and seeks to get the latest copy of the data and bring its map back up to
+date. Depending upon how long the Ceph OSD Daemon was down, the OSD's objects
+and placement groups may be significantly out of date. Also, if a failure domain
+went down (e.g., a rack), more than one Ceph OSD Daemon may come back online at
+the same time. This can make the recovery process time consuming and resource
+intensive.
+
+To maintain operational performance, Ceph performs recovery with limitations on
+the number recovery requests, threads and object chunk sizes which allows Ceph
+perform well in a degraded state.
+
+.. confval:: osd_recovery_delay_start
+.. confval:: osd_recovery_max_active
+.. confval:: osd_recovery_max_active_hdd
+.. confval:: osd_recovery_max_active_ssd
+.. confval:: osd_recovery_max_chunk
+.. confval:: osd_recovery_max_single_start
+.. confval:: osd_recover_clone_overlap
+.. confval:: osd_recovery_sleep
+.. confval:: osd_recovery_sleep_hdd
+.. confval:: osd_recovery_sleep_ssd
+.. confval:: osd_recovery_sleep_hybrid
+.. confval:: osd_recovery_priority
+
+Tiering
+=======
+
+.. confval:: osd_agent_max_ops
+.. confval:: osd_agent_max_low_ops
+
+See `cache target dirty high ratio`_ for when the tiering agent flushes dirty
+objects within the high speed mode.
+
+Miscellaneous
+=============
+
+.. confval:: osd_default_notify_timeout
+.. confval:: osd_check_for_log_corruption
+.. confval:: osd_delete_sleep
+.. confval:: osd_delete_sleep_hdd
+.. confval:: osd_delete_sleep_ssd
+.. confval:: osd_delete_sleep_hybrid
+.. confval:: osd_command_max_records
+.. confval:: osd_fast_fail_on_connection_refused
+
+.. _pool: ../../operations/pools
+.. _Configuring Monitor/OSD Interaction: ../mon-osd-interaction
+.. _Monitoring OSDs and PGs: ../../operations/monitoring-osd-pg#peering
+.. _Pool & PG Config Reference: ../pool-pg-config-ref
+.. _Journal Config Reference: ../journal-ref
+.. _cache target dirty high ratio: ../../operations/pools#cache-target-dirty-high-ratio
+.. _mClock Config Reference: ../mclock-config-ref