#!/usr/bin/env bash testdir=$(readlink -f $(dirname $0)) rootdir=$(readlink -f $testdir/../../..) source $rootdir/test/common/autotest_common.sh function run_spdk_fio() { fio_bdev --ioengine=spdk_bdev "$@" --spdk_mem=1024 --spdk_single_seg=1 \ --verify_state_save=0 } function err_cleanup() { rm -f $testdir/bdev.json killprocess $vhost_pid if [[ -n "$dummy_spdk_pid" ]] && kill -0 $dummy_spdk_pid &> /dev/null; then killprocess $dummy_spdk_pid fi } # start vhost and configure it trap 'err_cleanup; exit 1' SIGINT SIGTERM EXIT $SPDK_BIN_DIR/vhost & vhost_pid=$! waitforlisten $vhost_pid $rootdir/scripts/gen_nvme.sh --json | $rootdir/scripts/rpc.py load_subsystem_config if [ -z "$(rpc_cmd bdev_get_bdevs | jq '.[] | select(.name=="Nvme0n1")')" ]; then echo "Nvme0n1 bdev not found!" && false fi rpc_cmd bdev_split_create Nvme0n1 6 rpc_cmd vhost_create_scsi_controller naa.Nvme0n1_scsi0.0 rpc_cmd vhost_scsi_controller_add_target naa.Nvme0n1_scsi0.0 0 Nvme0n1p0 rpc_cmd vhost_scsi_controller_add_target naa.Nvme0n1_scsi0.0 1 Nvme0n1p1 rpc_cmd vhost_scsi_controller_add_target naa.Nvme0n1_scsi0.0 2 Nvme0n1p2 rpc_cmd vhost_scsi_controller_add_target naa.Nvme0n1_scsi0.0 3 Nvme0n1p3 rpc_cmd vhost_create_blk_controller naa.Nvme0n1_blk0.0 Nvme0n1p4 rpc_cmd vhost_create_blk_controller naa.Nvme0n1_blk1.0 Nvme0n1p5 rpc_cmd bdev_malloc_create 128 512 --name Malloc0 rpc_cmd vhost_create_scsi_controller naa.Malloc0.0 rpc_cmd vhost_scsi_controller_add_target naa.Malloc0.0 0 Malloc0 rpc_cmd bdev_malloc_create 128 4096 --name Malloc1 rpc_cmd vhost_create_scsi_controller naa.Malloc1.0 rpc_cmd vhost_scsi_controller_add_target naa.Malloc1.0 0 Malloc1 # start a dummy app, create vhost bdevs in it, then dump the config for FIO $SPDK_BIN_DIR/spdk_tgt -r /tmp/spdk2.sock -g & dummy_spdk_pid=$! waitforlisten $dummy_spdk_pid /tmp/spdk2.sock rpc_cmd -s /tmp/spdk2.sock bdev_virtio_attach_controller --trtype user --traddr 'naa.Nvme0n1_scsi0.0' -d scsi --vq-count 8 'VirtioScsi0' rpc_cmd -s /tmp/spdk2.sock bdev_virtio_attach_controller --trtype user --traddr 'naa.Nvme0n1_blk0.0' -d blk --vq-count 8 'VirtioBlk3' rpc_cmd -s /tmp/spdk2.sock bdev_virtio_attach_controller --trtype user --traddr 'naa.Nvme0n1_blk1.0' -d blk --vq-count 8 'VirtioBlk4' rpc_cmd -s /tmp/spdk2.sock bdev_virtio_attach_controller --trtype user --traddr 'naa.Malloc0.0' -d scsi --vq-count 8 'VirtioScsi1' rpc_cmd -s /tmp/spdk2.sock bdev_virtio_attach_controller --trtype user --traddr 'naa.Malloc1.0' -d scsi --vq-count 8 'VirtioScsi2' cat <<- CONF > $testdir/bdev.json {"subsystems":[ $(rpc_cmd -s /tmp/spdk2.sock save_subsystem_config -n bdev) ]} CONF killprocess $dummy_spdk_pid # run FIO with previously acquired spdk config files timing_enter run_spdk_fio run_spdk_fio $testdir/bdev.fio --filename=* --section=job_randwrite --spdk_json_conf=$testdir/bdev.json timing_exit run_spdk_fio timing_enter run_spdk_fio_unmap run_spdk_fio $testdir/bdev.fio --filename="VirtioScsi1t0:VirtioScsi2t0" --spdk_json_conf=$testdir/bdev.json timing_exit run_spdk_fio_unmap rpc_cmd bdev_nvme_detach_controller Nvme0 trap - SIGINT SIGTERM EXIT rm -f $testdir/bdev.json killprocess $vhost_pid