+#!/bin/sh
+#
+# External STONITH module for APC Switched Rack PDU
+#
+# Copyright (c) 2008 Sergey Maznichenko <msergeyb@gmail.com> <inbox@it-consultant.su>
+# Version 1.2
+#
+# See http://www.it-consultant.su/rackpdu
+# for additional information
+#
+# This program is free software; you can redistribute it and/or modify
+# it under the terms of version 2 of the GNU General Public License as
+# published by the Free Software Foundation.
+#
+# This program is distributed in the hope that it would be useful, but
+# WITHOUT ANY WARRANTY; without even the implied warranty of
+# MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE.
+#
+# Further, this software is distributed without any warranty that it is
+# free of the rightful claim of any third person regarding infringement
+# or the like. Any license provided herein, whether implied or
+# otherwise, applies only to this software file. Patent licenses, if
+# any, provided herein do not apply to combinations of this program with
+# other software, or any other product whatsoever.
+#
+# You should have received a copy of the GNU General Public License
+# along with this program; if not, write the Free Software Foundation,
+# Inc., 59 Temple Place - Suite 330, Boston MA 02111-1307, USA.
+#
+
+SWITCH_ON="1"
+SWITCH_OFF="2"
+SWITCH_RESET="3"
+
+DEFAULT_NAMES_OID=".1.3.6.1.4.1.318.1.1.12.3.3.1.1.2"
+DEFAULT_COMMAND_OID=".1.3.6.1.4.1.318.1.1.12.3.3.1.1.4"
+
+if [ -z "$oid" ]; then
+ oid=$DEFAULT_COMMAND_OID
+fi
+
+if [ -z "$names_oid" ]; then
+ names_oid=$DEFAULT_NAMES_OID
+fi
+
+if [ -z "$outlet_config" ]; then
+ outlet_config="none"
+fi
+
+GetOutletNumber() {
+ local nodename=$1
+
+ if [ "$outlet_config" != "none" ]; then
+ # Get outlet number from file
+
+ if [ -f "$outlet_config" ]; then
+ local outlet_num=`grep $nodename $outlet_config | tr -d ' ' | cut -f2 -d'='`
+ if [ -z "$outlet_num" ]; then
+ ha_log.sh err "Outlet number not found for node $nodename. Check configuration file $outlet_config"
+ return 0
+ fi
+ return $outlet_num
+ else
+ ha_log.sh err "File $outlet_config not found."
+ return 0
+ fi
+ else
+ # Get outlet number from device
+
+ local outlet_num=1
+ local snmp_result
+ snmp_result=`snmpwalk -v1 -c $community $pduip $names_oid 2>&1`
+ if [ $? -ne 0 ]; then
+ ha_log.sh err "snmpwalk $community $pduip $names_oid failed. Result: $snmp_result"
+ return 0
+ fi
+
+ local names
+ names=`echo "$snmp_result" | cut -f2 -d'"' | tr ' ' '_' | tr '\012' ' '`
+ for name in $names; do
+ if [ "$name" != "$nodename" ]; then
+ local outlet_num=`expr $outlet_num + 1`
+ continue
+ fi
+
+ return $outlet_num
+ done
+
+ ha_log.sh err "Outlet number not found for node $nodename. Result: $snmp_result"
+ return 0
+ fi
+}
+
+SendCommand() {
+
+ local host=$1
+ local command=$2
+
+ GetOutletNumber $host
+ local outlet=$?
+
+ if [ $outlet -gt 0 ]; then
+ local set_result
+ set_result=`snmpset -v1 -c $community $pduip $oid.$outlet i $command 2>&1`
+ if [ $? -ne 0 ]; then
+ ha_log.sh err "Write SNMP to $pduip value $oid.$outlet=$command failed. Result: $set_result"
+ return 1
+ fi
+ if echo "$set_result" | grep -qs "Timeout"; then
+ ha_log.sh err "Write SNMP to $pduip value $oid.$outlet=$command timed out. Result: $set_result"
+ return 1
+ fi
+ return 0
+ else
+ return 1
+ fi
+}
+
+hostlist=`echo $hostlist | tr ',' ' '`
+incommand=$1
+innode=$2
+
+case $incommand in
+gethosts)
+ if [ "$hostlist" = "AUTO" ]; then
+ snmp_result=`snmpwalk -v1 -c $community $pduip $names_oid 2>&1`
+ if [ $? -ne 0 ]; then
+ ha_log.sh err "snmpwalk $community $pduip $names_oid failed. Result: $snmp_result"
+ exit 1
+ fi
+ if echo "$snmp_result" | grep -qs "Timeout"; then
+ ha_log.sh err "snmpwalk $community $pduip $names_oid timed out. Result: $snmp_result"
+ exit 1
+ else
+ hostlist=`echo "$snmp_result" | cut -f2 -d'"' | tr ' ' '_' | tr '\012' ' '`
+ fi
+ fi
+
+ for h in $hostlist ; do
+ echo $h
+ done
+
+ exit 0
+ ;;
+on)
+ if
+ SendCommand $innode $SWITCH_ON
+ then
+ exit 0
+ else
+ exit 1
+ fi
+ ;;
+off)
+ if
+ SendCommand $innode $SWITCH_OFF
+ then
+ exit 0
+ else
+ exit 1
+ fi
+ ;;
+reset)
+ if
+ SendCommand $innode $SWITCH_RESET
+ then
+ exit 0
+ else
+ exit 1
+ fi
+ ;;
+status)
+ if [ -z "$pduip" ]; then
+ exit 1
+ fi
+
+ if ping -w1 -c1 $pduip >/dev/null 2>&1; then
+ exit 0
+ else
+ exit 1
+ fi
+ ;;
+getconfignames)
+ echo "hostlist pduip community"
+ exit 0
+ ;;
+getinfo-devid)
+ echo "rackpdu STONITH device"
+ exit 0
+ ;;
+getinfo-devname)
+ echo "rackpdu STONITH external device"
+ exit 0
+ ;;
+getinfo-devdescr)
+ echo "APC Switched Rack PDU"
+ exit 0
+ ;;
+getinfo-devurl)
+ echo "http://www.apcc.com/products/family/index.cfm?id=30"
+ exit 0
+ ;;
+getinfo-xml)
+ cat << PDUXML
+<parameters>
+ <parameter name="hostlist" unique="1" required="1">
+ <content type="string" default="AUTO" />
+ <shortdesc lang="en">Hostlist</shortdesc>
+ <longdesc lang="en">
+The list of hosts that the STONITH device controls (comma or space separated).
+If you set value of this parameter to AUTO, list of hosts will be get from Rack PDU device.
+ </longdesc>
+ </parameter>
+
+ <parameter name="pduip" unique="1" required="1">
+ <content type="string" />
+ <shortdesc lang="en">Name or IP address of Rack PDU device.</shortdesc>
+ <longdesc lang="en">Name or IP address of Rack PDU device.</longdesc>
+ </parameter>
+
+ <parameter name="community" unique="1" required="1">
+ <content type="string" default="private" />
+ <shortdesc lang="en">Name of write community.</shortdesc>
+ <longdesc lang="en">Name of write community.</longdesc>
+ </parameter>
+
+ <parameter name="oid" unique="1" required="0">
+ <content type="string" />
+ <shortdesc lang="en">
+ The OID without the outlet number.
+ </shortdesc>
+ <longdesc lang="en">
+The SNMP OID for the PDU. minus the outlet number.
+Try .1.3.6.1.4.1.318.1.1.12.3.3.1.1.4 (default value)
+or use mib from ftp://ftp.apcc.com/apc/public/software/pnetmib/mib/
+Varies on different APC hardware and firmware.
+Warning! No dot at the end of OID
+ </longdesc>
+ </parameter>
+
+ <parameter name="names_oid" unique="1" required="0">
+ <content type="string" />
+ <shortdesc lang="en">The OID for getting names of outlets.</shortdesc>
+ <longdesc lang="en">
+The SNMP OID for getting names of outlets.
+It is required to recognize outlet number by nodename.
+Try ".1.3.6.1.4.1.318.1.1.12.3.3.1.1.2" (default value)
+or use mib from ftp://ftp.apcc.com/apc/public/software/pnetmib/mib/
+Names of nodes must be equal names of outlets, in other way use outlet_config parameter.
+If you set 'names_oid' parameter then parameter outlet_config must not be use.
+Varies on different APC hardware and firmware.
+Warning! No dot at the end of OID
+ </longdesc>
+ </parameter>
+
+ <parameter name="outlet_config" unique="1" required="0">
+ <content type="string" />
+ <shortdesc lang="en">Configuration file. Other way to recognize outlet number by nodename.</shortdesc>
+ <longdesc lang="en">
+Configuration file. Other way to recognize outlet number by nodename.
+Configuration file which contains
+node_name=outlet_number
+strings.
+
+Example:
+server1=1
+server2=2
+
+If you use outlet_config parameter then names_oid parameter can have any value and it is not uses.
+ </longdesc>
+ </parameter>
+
+</parameters>
+PDUXML
+ exit 0
+ ;;
+*)
+ exit 1
+ ;;
+esac