From 9cb1c4df7b9ce1a9ad1312621b0f2b16a94fba3a Mon Sep 17 00:00:00 2001 From: Daniel Baumann Date: Mon, 3 Jun 2024 15:54:25 +0200 Subject: Adding upstream version 060+5. Signed-off-by: Daniel Baumann --- modules.d/95iscsi/module-setup.sh | 294 ++++++++++++++++++++++++++++++++++++++ 1 file changed, 294 insertions(+) create mode 100755 modules.d/95iscsi/module-setup.sh (limited to 'modules.d/95iscsi/module-setup.sh') diff --git a/modules.d/95iscsi/module-setup.sh b/modules.d/95iscsi/module-setup.sh new file mode 100755 index 0000000..2bea2fc --- /dev/null +++ b/modules.d/95iscsi/module-setup.sh @@ -0,0 +1,294 @@ +#!/bin/bash + +# called by dracut +check() { + # If our prerequisites are not met, fail anyways. + require_binaries iscsi-iname iscsiadm iscsid || return 1 + require_kernel_modules iscsi_tcp || return 1 + + # If hostonly was requested, fail the check if we are not actually + # booting from root. + [[ $hostonly ]] || [[ $mount_needs ]] && { + pushd . > /dev/null + for_each_host_dev_and_slaves block_is_iscsi + local _is_iscsi=$? + popd > /dev/null || exit + [[ $_is_iscsi == 0 ]] || return 255 + } + return 0 +} + +get_ibft_mod() { + local ibft_mac=$1 + local iface_mac iface_mod + # Return the iSCSI offload module for a given MAC address + for iface_desc in $(iscsiadm -m iface | cut -f 2 -d ' '); do + iface_mod=${iface_desc%%,*} + iface_mac=${iface_desc#*,} + iface_mac=${iface_mac%%,*} + if [ "$ibft_mac" = "$iface_mac" ]; then + echo "$iface_mod" + return 0 + fi + done +} + +install_ibft() { + # When iBFT / iscsi_boot is detected: + # - Use 'ip=ibft' to set up iBFT network interface + # Note: bnx2i is using a different MAC address of iSCSI offloading + # so the 'ip=ibft' parameter must not be set + # - specify firmware booting cmdline parameter + + for d in /sys/firmware/*; do + if [ -d "${d}"/ethernet0 ]; then + read -r ibft_mac < "${d}"/ethernet0/mac + ibft_mod=$(get_ibft_mod "$ibft_mac") + fi + if [ -z "$ibft_mod" ] && [ -d "${d}"/ethernet1 ]; then + read -r ibft_mac < "${d}"/ethernet1/mac + ibft_mod=$(get_ibft_mod "$ibft_mac") + fi + if [ -d "${d}"/initiator ]; then + if [ "${d##*/}" = "ibft" ] && [ "$ibft_mod" != "bnx2i" ]; then + echo -n "rd.iscsi.ibft=1 " + fi + echo -n "rd.iscsi.firmware=1 " + fi + done +} + +install_iscsiroot() { + local devpath=$1 + local scsi_path iscsi_lun session c d conn host flash + local iscsi_session iscsi_address iscsi_port iscsi_targetname + + scsi_path=${devpath%%/block*} + [ "$scsi_path" = "$devpath" ] && return 1 + iscsi_lun=${scsi_path##*:} + [ "$iscsi_lun" = "$scsi_path" ] && return 1 + session=${devpath%%/target*} + [ "$session" = "$devpath" ] && return 1 + iscsi_session=${session##*/} + [ "$iscsi_session" = "$session" ] && return 1 + host=${session%%/session*} + [ "$host" = "$session" ] && return 1 + iscsi_host=${host##*/} + + for flash in "${host}"/flashnode_sess-*; do + [ -f "$flash" ] || continue + [ ! -e "$flash/is_boot_target" ] && continue + read -r is_boot < "$flash"/is_boot_target + if [ "$is_boot" -eq 1 ]; then + # qla4xxx flashnode session; skip iBFT discovery + read -r iscsi_initiator < /sys/class/iscsi_host/"${iscsi_host}"/initiatorname + echo "rd.iscsi.initiator=${iscsi_initiator}" + return + fi + done + + for d in "${session}"/*; do + case $d in + *connection*) + c=${d##*/} + conn=${d}/iscsi_connection/${c} + if [ -d "${conn}" ]; then + read -r iscsi_address < "${conn}"/persistent_address + read -r iscsi_port < "${conn}"/persistent_port + fi + ;; + *session) + if [ -d "${d}"/"${iscsi_session}" ]; then + read -r iscsi_initiator < "${d}"/"${iscsi_session}"/initiatorname + read -r iscsi_targetname < "${d}"/"${iscsi_session}"/targetname + fi + ;; + esac + done + + [ -z "$iscsi_address" ] && return + ip_params_for_remote_addr "$iscsi_address" + + if [ -n "$iscsi_address" -a -n "$iscsi_targetname" ]; then + if [ -n "$iscsi_port" -a "$iscsi_port" -eq 3260 ]; then + iscsi_port= + fi + if [ -n "$iscsi_lun" -a "$iscsi_lun" -eq 0 ]; then + iscsi_lun= + fi + # In IPv6 case rd.iscsi.initatior= must pass address in [] brackets + case "$iscsi_address" in + *:*) + iscsi_address="[$iscsi_address]" + ;; + esac + # Must be two separate lines, so that "sort | uniq" commands later + # can sort out rd.iscsi.initiator= duplicates + echo "rd.iscsi.initiator=${iscsi_initiator}" + echo "netroot=iscsi:${iscsi_address}::${iscsi_port}:${iscsi_lun}:${iscsi_targetname}" + echo "rd.neednet=1" + fi + return 0 +} + +install_softiscsi() { + [ -d /sys/firmware/ibft ] && return 0 + + is_softiscsi() { + local _dev=$1 + local iscsi_dev + + [[ -L "/sys/dev/block/$_dev" ]] || return + iscsi_dev=$( + cd -P /sys/dev/block/"$_dev" || exit + echo "$PWD" + ) + install_iscsiroot "$iscsi_dev" + } + + for_each_host_dev_and_slaves_all is_softiscsi || return 255 + return 0 +} + +# called by dracut +depends() { + echo network rootfs-block +} + +# called by dracut +installkernel() { + local _arch=${DRACUT_ARCH:-$(uname -m)} + local _funcs='iscsi_register_transport' + + instmods bnx2i qla4xxx cxgb3i cxgb4i be2iscsi qedi + hostonly="" instmods iscsi_tcp iscsi_ibft crc32c iscsi_boot_sysfs 8021q + + if [ "$_arch" = "s390" -o "$_arch" = "s390x" ]; then + _s390drivers="=drivers/s390/scsi" + fi + + dracut_instmods -o -s ${_funcs} =drivers/scsi ${_s390drivers:+"$_s390drivers"} +} + +# called by dracut +cmdline() { + local _iscsiconf + _iscsiconf=$(install_ibft) + { + if [ "$_iscsiconf" ]; then + echo "${_iscsiconf}" + else + install_softiscsi + fi + } | sort | uniq +} + +# called by dracut +install() { + inst_multiple -o iscsiuio + inst_libdir_file 'libgcc_s.so*' + inst_multiple umount iscsi-iname iscsiadm iscsid + inst_binary sort + + inst_multiple -o \ + "$systemdsystemunitdir"/iscsid.socket \ + "$systemdsystemunitdir"/iscsid.service \ + "$systemdsystemunitdir"/iscsiuio.service \ + "$systemdsystemunitdir"/iscsiuio.socket \ + "$systemdsystemunitdir"/sockets.target.wants/iscsid.socket \ + "$systemdsystemunitdir"/sockets.target.wants/iscsiuio.socket + + if [[ $hostonly ]]; then + local -a _filenames + + inst_dir /etc/iscsi + mapfile -t -d '' _filenames < <(find /etc/iscsi -type f -print0) + inst_multiple "${_filenames[@]}" + else + inst_simple /etc/iscsi/iscsid.conf + fi + + # Detect iBFT and perform mandatory steps + if [[ $hostonly_cmdline == "yes" ]]; then + local _iscsiconf + _iscsiconf=$(cmdline) + [[ $_iscsiconf ]] && printf "%s\n" "$_iscsiconf" >> "${initdir}/etc/cmdline.d/95iscsi.conf" + fi + + inst_hook cmdline 90 "$moddir/parse-iscsiroot.sh" + inst_hook cleanup 90 "$moddir/cleanup-iscsi.sh" + inst "$moddir/iscsiroot.sh" "/sbin/iscsiroot" + + if ! dracut_module_included "systemd"; then + inst "$moddir/mount-lun.sh" "/bin/mount-lun.sh" + else + inst_multiple -o \ + "$systemdsystemunitdir"/iscsi.service \ + "$systemdsystemunitdir"/iscsi-init.service \ + "$systemdsystemunitdir"/iscsid.service \ + "$systemdsystemunitdir"/iscsid.socket \ + "$systemdsystemunitdir"/iscsiuio.service \ + "$systemdsystemunitdir"/iscsiuio.socket \ + iscsiadm iscsid + + for i in \ + iscsid.socket \ + iscsiuio.socket; do + $SYSTEMCTL -q --root "$initdir" enable "$i" + done + + mkdir -p "${initdir}/$systemdsystemunitdir/iscsid.service.d" + { + echo "[Unit]" + echo "DefaultDependencies=no" + echo "Conflicts=shutdown.target" + echo "Before=shutdown.target" + } > "${initdir}/$systemdsystemunitdir/iscsid.service.d/dracut.conf" + + mkdir -p "${initdir}/$systemdsystemunitdir/iscsid.socket.d" + { + echo "[Unit]" + echo "DefaultDependencies=no" + echo "Conflicts=shutdown.target" + echo "Before=shutdown.target sockets.target" + } > "${initdir}/$systemdsystemunitdir/iscsid.socket.d/dracut.conf" + + mkdir -p "${initdir}/$systemdsystemunitdir/iscsiuio.service.d" + { + echo "[Unit]" + echo "DefaultDependencies=no" + echo "Conflicts=shutdown.target" + echo "Before=shutdown.target" + } > "${initdir}/$systemdsystemunitdir/iscsiuio.service.d/dracut.conf" + + mkdir -p "${initdir}/$systemdsystemunitdir/iscsiuio.socket.d" + { + echo "[Unit]" + echo "DefaultDependencies=no" + echo "Conflicts=shutdown.target" + echo "Before=shutdown.target sockets.target" + } > "${initdir}/$systemdsystemunitdir/iscsiuio.socket.d/dracut.conf" + + # Fedora 34 iscsid requires iscsi-shutdown.service + # which would terminate all iSCSI connections on switch root + cat > "${initdir}/$systemdsystemunitdir/iscsi-shutdown.service" << EOF +[Unit] +Description=Dummy iscsi-shutdown.service for the initrd +Documentation=man:iscsid(8) man:iscsiadm(8) +DefaultDependencies=no +Conflicts=shutdown.target +After=systemd-remount-fs.service network.target iscsid.service iscsiuio.service +Before=remote-fs-pre.target + +[Service] +Type=oneshot +RemainAfterExit=false +ExecStart=-/usr/bin/true +EOF + fi + inst_dir /var/lib/iscsi + mkdir -p "${initdir}/var/lib/iscsi/nodes" + # Fedora 34 iscsid wants a non-empty /var/lib/iscsi/nodes directory + : > "${initdir}/var/lib/iscsi/nodes/.dracut" + dracut_need_initqueue +} -- cgit v1.2.3