#!/bin/bash # -*- mode: shell-script; indent-tabs-mode: nil; sh-basic-offset: 4; -*- # ex: ts=8 sw=4 sts=4 et filetype=sh # shellcheck disable=SC2034 TEST_DESCRIPTION="root filesystem on NFS with bridging/bonding/vlan with $USE_NETWORK" # Uncomment this to debug failures #DEBUGFAIL="rd.shell rd.break" #SERIAL="tcp:127.0.0.1:9999" # skip the test if ifcfg dracut module can not be installed test_check() { test -d /etc/sysconfig/network-scripts } # Network topology: # # .---------------------. .---------------. # | SERVER-VM | | CLIENT-VM | # | | | | # | (DHCP) net1 <------------> net1 | # | | | | # | net2 <------------> net2 | # | vlan 1 <-| | | | # | vlan 2 <-| | | | # | vlan 3 <-| | | | # | vlan 4 <-. | | | # | | | | # | / net3 <------------> net3 | # | bond0 | | | | # | (DHCP) \ net4 <------------> net4 | # | | | | # | | X-----> net5 | # .---------------------. .---------------. run_server() { # Start server first echo "MULTINIC TEST SETUP: Starting DHCP/NFS server" "$testdir"/run-qemu \ -netdev socket,id=n0,listen=127.0.0.1:12370 \ -netdev socket,id=n1,listen=127.0.0.1:12371 \ -netdev socket,id=n2,listen=127.0.0.1:12372 \ -netdev socket,id=n3,listen=127.0.0.1:12373 \ -device virtio-net-pci,netdev=n0,mac=52:54:01:12:34:56 \ -device virtio-net-pci,netdev=n1,mac=52:54:01:12:34:57 \ -device virtio-net-pci,netdev=n2,mac=52:54:01:12:34:58 \ -device virtio-net-pci,netdev=n3,mac=52:54:01:12:34:59 \ -hda "$TESTDIR"/server.ext4 \ -serial "${SERIAL:-"file:$TESTDIR/server.log"}" \ -append "panic=1 oops=panic softlockup_panic=1 root=LABEL=dracut rootfstype=ext4 rw console=ttyS0,115200n81" \ -initrd "$TESTDIR"/initramfs.server \ -pidfile "$TESTDIR"/server.pid -daemonize || return 1 chmod 644 -- "$TESTDIR"/server.pid || return 1 # Cleanup the terminal if we have one tty -s && stty sane if ! [[ $SERIAL ]]; then echo "Waiting for the server to startup" while :; do grep Serving "$TESTDIR"/server.log && break tail "$TESTDIR"/server.log sleep 1 done else echo Sleeping 10 seconds to give the server a head start sleep 10 fi } client_test() { local test_name="$1" local cmdline="$2" local check="$3" local CONF echo "CLIENT TEST START: $test_name" # Need this so kvm-qemu will boot (needs non-/dev/zero local disk) if ! dd if=/dev/zero of="$TESTDIR"/client.img bs=1M count=1; then echo "Unable to make client sda image" 1>&2 return 1 fi "$testdir"/run-qemu \ -netdev socket,connect=127.0.0.1:12370,id=n1 -device virtio-net-pci,mac=52:54:00:12:34:01,netdev=n1 \ -netdev socket,connect=127.0.0.1:12371,id=n2 -device virtio-net-pci,mac=52:54:00:12:34:02,netdev=n2 \ -netdev socket,connect=127.0.0.1:12372,id=n3 -device virtio-net-pci,mac=52:54:00:12:34:03,netdev=n3 \ -netdev socket,connect=127.0.0.1:12373,id=n4 -device virtio-net-pci,mac=52:54:00:12:34:04,netdev=n4 \ -netdev hubport,id=n5,hubid=1 -device virtio-net-pci,mac=52:54:00:12:34:05,netdev=n5 \ -hda "$TESTDIR"/client.img \ -append " $TEST_KERNEL_CMDLINE ifname=net1:52:54:00:12:34:01 ifname=net2:52:54:00:12:34:02 ifname=net3:52:54:00:12:34:03 ifname=net4:52:54:00:12:34:04 ifname=net5:52:54:00:12:34:05 $cmdline rd.net.timeout.dhcp=30 rd.retry=5 rw init=/sbin/init" \ -initrd "$TESTDIR"/initramfs.testing || return 1 { read -r OK _ if [[ $OK != "OK" ]]; then echo "CLIENT TEST END: $test_name [FAILED - BAD EXIT]" return 1 fi while read -r line; do [[ $line == END ]] && break CONF+="$line " done } < "$TESTDIR"/client.img || return 1 if [[ $check != "$CONF" ]]; then echo "Expected: '$check'" echo echo echo "Got: '$CONF'" echo "CLIENT TEST END: $test_name [FAILED - BAD CONF]" return 1 fi echo "CLIENT TEST END: $test_name [OK]" return 0 } test_run() { if ! run_server; then echo "Failed to start server" 1>&2 return 1 fi test_client || { kill_server return 1 } } test_client() { ### TEST 1: VLANs if [ "$USE_NETWORK" = network-legacy ]; then NETCONF='ifcfg-net1 # Generated by dracut initrd NAME="net1" HWADDR="52:54:00:12:34:01" DEVICE="net1" ONBOOT=yes NETBOOT=yes IPV6INIT=yes BOOTPROTO=dhcp TYPE=Ethernet ifcfg-net2.0004 # Generated by dracut initrd NAME="net2.0004" ONBOOT=yes NETBOOT=yes BOOTPROTO=none IPADDR="192.168.57.104" PREFIX="24" GATEWAY="192.168.57.1" TYPE=Vlan DEVICE="net2.0004" VLAN=yes PHYSDEV="net2" ifcfg-net2.3 # Generated by dracut initrd NAME="net2.3" ONBOOT=yes NETBOOT=yes BOOTPROTO=none IPADDR="192.168.56.103" PREFIX="24" GATEWAY="192.168.56.1" TYPE=Vlan DEVICE="net2.3" VLAN=yes PHYSDEV="net2" ifcfg-vlan0001 # Generated by dracut initrd NAME="vlan0001" ONBOOT=yes NETBOOT=yes BOOTPROTO=none IPADDR="192.168.54.101" PREFIX="24" GATEWAY="192.168.54.1" TYPE=Vlan DEVICE="vlan0001" VLAN=yes PHYSDEV="net2" ifcfg-vlan2 # Generated by dracut initrd NAME="vlan2" ONBOOT=yes NETBOOT=yes BOOTPROTO=none IPADDR="192.168.55.102" PREFIX="24" GATEWAY="192.168.55.1" TYPE=Vlan DEVICE="vlan2" VLAN=yes PHYSDEV="net2" ' fi client_test "VLANs" \ " rd.dracut.test.num=1 rd.dracut.test.net-module=$USE_NETWORK vlan=vlan0001:net2 vlan=vlan2:net2 vlan=net2.3:net2 vlan=net2.0004:net2 ip=net1:dhcp ip=192.168.54.101::192.168.54.1:24:test:vlan0001:none ip=192.168.55.102::192.168.55.1:24:test:vlan2:none ip=192.168.56.103::192.168.56.1:24:test:net2.3:none ip=192.168.57.104::192.168.57.1:24:test:net2.0004:none rd.neednet=1 root=nfs:192.168.50.1:/nfs/client bootdev=net1 " \ "net1 net2.0004 net2.3 vlan0001 vlan2 PING1=0 PING2=0 PING3=0 PING4=0 PING5=0 ${NETCONF}EOF " \ || return 1 ### TEST 2: bond if [ "$USE_NETWORK" = network-legacy ]; then NETCONF='ifcfg-bond0 # Generated by dracut initrd NAME="bond0" DEVICE="bond0" ONBOOT=yes NETBOOT=yes IPV6INIT=yes BOOTPROTO=dhcp BONDING_OPTS="miimon=100" NAME="bond0" TYPE=Bond ifcfg-net3 # Generated by dracut initrd NAME="net3" TYPE=Ethernet ONBOOT=yes NETBOOT=yes SLAVE=yes MASTER="bond0" DEVICE="net3" ifcfg-net4 # Generated by dracut initrd NAME="net4" TYPE=Ethernet ONBOOT=yes NETBOOT=yes SLAVE=yes MASTER="bond0" DEVICE="net4" ' fi client_test "Bond" \ " rd.dracut.test.num=2 rd.dracut.test.net-module=$USE_NETWORK bond=bond0:net3,net4:miimon=100 ip=bond0:dhcp rd.neednet=1 root=nfs:192.168.51.1:/nfs/client bootdev=bond0 " \ "bond0 PING1=0 NET3=0 NET4=0 ${NETCONF}EOF " \ || return 1 ### TEST 3: bridge if [ "$USE_NETWORK" = network-legacy ]; then NETCONF='ifcfg-br0 # Generated by dracut initrd NAME="br0" DEVICE="br0" ONBOOT=yes NETBOOT=yes IPV6INIT=yes BOOTPROTO=dhcp TYPE=Bridge NAME="br0" ifcfg-net1 # Generated by dracut initrd NAME="net1" TYPE=Ethernet ONBOOT=yes NETBOOT=yes BRIDGE="br0" HWADDR="52:54:00:12:34:01" DEVICE="net1" ifcfg-net5 # Generated by dracut initrd NAME="net5" TYPE=Ethernet ONBOOT=yes NETBOOT=yes BRIDGE="br0" HWADDR="52:54:00:12:34:05" DEVICE="net5" ' fi client_test "Bridge" \ " rd.dracut.test.num=3 rd.dracut.test.net-module=$USE_NETWORK bridge=br0:net1,net5 ip=br0:dhcp rd.neednet=1 root=nfs:192.168.50.1:/nfs/client bootdev=br0 " \ "br0 PING1=0 NET1=0 NET5=0 ${NETCONF}EOF " \ || return 1 kill_server return 0 } test_setup() { kernel=$KVERSION rm -rf -- "$TESTDIR"/overlay ( mkdir -p "$TESTDIR"/overlay/source # shellcheck disable=SC2030 export initdir=$TESTDIR/overlay/source # shellcheck disable=SC1090 . "$PKGLIBDIR"/dracut-init.sh ( cd "$initdir" || exit mkdir -p -- dev sys proc run etc var/run tmp var/lib/{dhcpd,rpcbind} mkdir -p -- var/lib/nfs/{v4recovery,rpc_pipefs} chmod 777 -- var/lib/rpcbind var/lib/nfs ) for _f in modules.builtin.bin modules.builtin; do [[ -f $srcmods/$_f ]] && break done || { dfatal "No modules.builtin.bin and modules.builtin found!" return 1 } for _f in modules.builtin.bin modules.builtin modules.order; do [[ -f $srcmods/$_f ]] && inst_simple "$srcmods/$_f" "/lib/modules/$kernel/$_f" done inst_multiple sh ls shutdown poweroff stty cat ps ln ip \ dmesg mkdir cp ping exportfs \ modprobe rpc.nfsd rpc.mountd showmount tcpdump \ /etc/services sleep mount chmod for _terminfodir in /lib/terminfo /etc/terminfo /usr/share/terminfo; do [ -f "${_terminfodir}"/l/linux ] && break done inst_multiple -o "${_terminfodir}"/l/linux type -P portmap > /dev/null && inst_multiple portmap type -P rpcbind > /dev/null && inst_multiple rpcbind [ -f /etc/netconfig ] && inst_multiple /etc/netconfig type -P dhcpd > /dev/null && inst_multiple dhcpd instmods nfsd sunrpc ipv6 lockd af_packet 8021q bonding inst_simple /etc/os-release inst ./server-init.sh /sbin/init inst ./exports /etc/exports inst ./dhcpd.conf /etc/dhcpd.conf inst_multiple -o {,/usr}/etc/nsswitch.conf {,/usr}/etc/rpc {,/usr}/etc/protocols inst_multiple -o rpc.idmapd /etc/idmapd.conf inst_libdir_file 'libnfsidmap_nsswitch.so*' inst_libdir_file 'libnfsidmap/*.so*' inst_libdir_file 'libnfsidmap*.so*' _nsslibs=$( cat "$dracutsysrootdir"/{,usr/}etc/nsswitch.conf 2> /dev/null \ | sed -e '/^#/d' -e 's/^.*://' -e 's/\[NOTFOUND=return\]//' \ | tr -s '[:space:]' '\n' | sort -u | tr -s '[:space:]' '|' ) _nsslibs=${_nsslibs#|} _nsslibs=${_nsslibs%|} inst_libdir_file -n "$_nsslibs" 'libnss_*.so*' inst /etc/passwd /etc/passwd inst /etc/group /etc/group cp -a -- /etc/ld.so.conf* "$initdir"/etc ldconfig -r "$initdir" dracut_kernel_post ) # Make client root inside server root ( # shellcheck disable=SC2030 # shellcheck disable=SC2031 export initdir=$TESTDIR/overlay/source/nfs/client # shellcheck disable=SC1090 . "$PKGLIBDIR"/dracut-init.sh inst_multiple sh shutdown poweroff stty cat ps ln ip \ mount dmesg mkdir cp ping grep ls sort dd sed basename for _terminfodir in /lib/terminfo /etc/terminfo /usr/share/terminfo; do [[ -f ${_terminfodir}/l/linux ]] && break done inst_multiple -o "${_terminfodir}"/l/linux inst_simple /etc/os-release inst ./client-init.sh /sbin/init ( cd "$initdir" || exit mkdir -p -- dev sys proc etc run mkdir -p -- var/lib/nfs/rpc_pipefs ) inst_multiple -o {,/usr}/etc/nsswitch.conf {,/usr}/etc/rpc {,/usr}/etc/protocols inst /etc/passwd /etc/passwd inst /etc/group /etc/group inst_multiple -o rpc.idmapd /etc/idmapd.conf inst_libdir_file 'libnfsidmap_nsswitch.so*' inst_libdir_file 'libnfsidmap/*.so*' inst_libdir_file 'libnfsidmap*.so*' _nsslibs=$( cat "$dracutsysrootdir"/{,usr/}etc/nsswitch.conf 2> /dev/null \ | sed -e '/^#/d' -e 's/^.*://' -e 's/\[NOTFOUND=return\]//' \ | tr -s '[:space:]' '\n' | sort -u | tr -s '[:space:]' '|' ) _nsslibs=${_nsslibs#|} _nsslibs=${_nsslibs%|} inst_libdir_file -n "$_nsslibs" 'libnss_*.so*' cp -a -- /etc/ld.so.conf* "$initdir"/etc ldconfig -r "$initdir" ) # second, install the files needed to make the root filesystem ( # shellcheck disable=SC2030 # shellcheck disable=SC2031 export initdir=$TESTDIR/overlay # shellcheck disable=SC1090 . "$PKGLIBDIR"/dracut-init.sh inst_multiple mkfs.ext4 poweroff cp umount sync dd inst_hook initqueue 01 ./create-root.sh inst_hook initqueue/finished 01 ./finished-false.sh ) # create an initramfs that will create the target root filesystem. # We do it this way so that we do not risk trashing the host mdraid # devices, volume groups, encrypted partitions, etc. "$DRACUT" -l -i "$TESTDIR"/overlay / \ -m "bash rootfs-block kernel-modules qemu" \ -d "piix ide-gd_mod ata_piix ext4 sd_mod" \ --nomdadmconf \ --no-hostonly-cmdline -N \ -f "$TESTDIR"/initramfs.makeroot "$KVERSION" || return 1 declare -a disk_args=() declare -i disk_index=0 qemu_add_drive disk_index disk_args "$TESTDIR"/marker.img marker 1 qemu_add_drive disk_index disk_args "$TESTDIR"/server.ext4 root 120 # Invoke KVM and/or QEMU to actually create the target filesystem. "$testdir"/run-qemu \ "${disk_args[@]}" \ -append "root=/dev/dracut/root rw rootfstype=ext4 quiet console=ttyS0,115200n81" \ -initrd "$TESTDIR"/initramfs.makeroot || return 1 test_marker_check dracut-root-block-created || return 1 rm -- "$TESTDIR"/marker.img rm -fr "$TESTDIR"/overlay # Make an overlay with needed tools for the test harness ( # shellcheck disable=SC2031 # shellcheck disable=SC2030 export initdir="$TESTDIR"/overlay # shellcheck disable=SC1090 . "$PKGLIBDIR"/dracut-init.sh inst_multiple poweroff shutdown inst_hook emergency 000 ./hard-off.sh inst_simple ./client.link /etc/systemd/network/01-client.link ) # Make client's dracut image test_dracut \ -a "debug ${USE_NETWORK} ifcfg" \ "$TESTDIR"/initramfs.testing ( # shellcheck disable=SC2031 export initdir="$TESTDIR"/overlay # shellcheck disable=SC1090 . "$PKGLIBDIR"/dracut-init.sh rm "$initdir"/etc/systemd/network/01-client.link inst_simple ./server.link /etc/systemd/network/01-server.link inst_hook pre-mount 99 ./wait-if-server.sh ) # Make server's dracut image "$DRACUT" -l -i "$TESTDIR"/overlay / \ --no-early-microcode \ -m "rootfs-block debug kernel-modules watchdog qemu network network-legacy" \ -d "ipvlan macvlan af_packet piix ide-gd_mod ata_piix ext4 sd_mod nfsv2 nfsv3 nfsv4 nfs_acl nfs_layout_nfsv41_files nfsd virtio-net i6300esb" \ --no-hostonly-cmdline -N \ -f "$TESTDIR"/initramfs.server "$KVERSION" || return 1 } kill_server() { if [[ -s "$TESTDIR"/server.pid ]]; then kill -TERM -- "$(cat "$TESTDIR"/server.pid)" rm -f -- "$TESTDIR"/server.pid fi } test_cleanup() { kill_server } # shellcheck disable=SC1090 . "$testdir"/test-functions