1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
|
#!/bin/sh
type getarg > /dev/null 2>&1 || . /lib/dracut-lib.sh
PATH=/usr/sbin:/usr/bin:/sbin:/bin
# Huh? Empty $1?
[ -z "$1" ] && exit 1
# Huh? Empty $2?
[ -z "$2" ] && exit 1
# Huh? Empty $3?
[ -z "$3" ] && exit 1
# root is in the form root=nbd:srv:port[:fstype[:rootflags[:nbdopts]]]
# shellcheck disable=SC2034
netif="$1"
nroot="$2"
NEWROOT="$3"
# If it's not nbd we don't continue
[ "${nroot%%:*}" = "nbd" ] || return
nroot=${nroot#nbd:}
nbdserver=${nroot%%:*}
if [ "${nbdserver%"${nbdserver#?}"}" = "[" ]; then
nbdserver=${nroot#[}
nbdserver=${nbdserver%%]:*}
nroot=${nroot#*]:}
else
nroot=${nroot#*:}
fi
nbdport=${nroot%%:*}
nroot=${nroot#*:}
nbdfstype=${nroot%%:*}
nroot=${nroot#*:}
nbdflags=${nroot%%:*}
nbdopts=${nroot#*:}
if [ "$nbdopts" = "$nbdflags" ]; then
unset nbdopts
fi
if [ "$nbdflags" = "$nbdfstype" ]; then
unset nbdflags
fi
if [ "$nbdfstype" = "$nbdport" ]; then
unset nbdfstype
fi
if [ -z "$nbdfstype" ]; then
nbdfstype=auto
fi
# look through the NBD options and pull out the ones that need to
# go before the host etc. Append a ',' so we know we terminate the loop
nbdopts=${nbdopts},
while [ -n "$nbdopts" ]; do
f=${nbdopts%%,*}
nbdopts=${nbdopts#*,}
if [ -z "$f" ]; then
break
fi
if [ -z "${f%bs=*}" -o -z "${f%timeout=*}" ]; then
preopts="$preopts $f"
continue
fi
opts="$opts $f"
done
# look through the flags and see if any are overridden by the command line
nbdflags=${nbdflags},
while [ -n "$nbdflags" ]; do
f=${nbdflags%%,*}
nbdflags=${nbdflags#*,}
if [ -z "$f" ]; then
break
fi
if [ "$f" = "ro" -o "$f" = "rw" ]; then
nbdrw=$f
continue
fi
fsopts=${fsopts:+$fsopts,}$f
done
getarg ro && nbdrw=ro
getarg rw && nbdrw=rw
fsopts=${fsopts:+$fsopts,}${nbdrw}
# XXX better way to wait for the device to be made?
i=0
while [ ! -b /dev/nbd0 ]; do
[ $i -ge 20 ] && exit 1
udevadm settle --exit-if-exists=/dev/nbd0
i=$((i + 1))
done
# If we didn't get a root= on the command line, then we need to
# add the udev rules for mounting the nbd0 device
if [ "$root" = "block:/dev/root" -o "$root" = "dhcp" ]; then
printf 'KERNEL=="nbd0", ENV{DEVTYPE}!="partition", ENV{ID_FS_TYPE}=="?*", SYMLINK+="root"\n' > /etc/udev/rules.d/99-nbd-root.rules
udevadm control --reload
wait_for_dev -n /dev/root
if [ -z "$DRACUT_SYSTEMD" ]; then
type write_fs_tab > /dev/null 2>&1 || . /lib/fs-lib.sh
write_fs_tab /dev/root "$nbdfstype" "$fsopts"
printf '/bin/mount %s\n' \
"$NEWROOT" \
> "$hookdir"/mount/01-$$-nbd.sh
else
mkdir -p /run/systemd/system/sysroot.mount.d
cat << EOF > /run/systemd/system/sysroot.mount.d/dhcp.conf
[Mount]
Where=/sysroot
What=/dev/root
Type=$nbdfstype
Options=$fsopts
EOF
systemctl --no-block daemon-reload
fi
# if we're on systemd, use the nbd-generator script
# to create the /sysroot mount.
fi
if ! [ "$nbdport" -gt 0 ] 2> /dev/null; then
nbdport="-name $nbdport"
fi
if ! nbd-client -check /dev/nbd0 > /dev/null; then
# shellcheck disable=SC2086
nbd-client -p -systemd-mark "$nbdserver" $nbdport /dev/nbd0 $opts || exit 1
fi
need_shutdown
exit 0
|