summaryrefslogtreecommitdiffstats
path: root/agents/apc_snmp/powernet369.mib
diff options
context:
space:
mode:
authorDaniel Baumann <daniel.baumann@progress-linux.org>2024-04-17 06:50:17 +0000
committerDaniel Baumann <daniel.baumann@progress-linux.org>2024-04-17 06:50:17 +0000
commit86ed03f8adee56c050c73018537371c230a664a6 (patch)
treeeae3d04cdf1c49848e5a671327ab38297f4acb0d /agents/apc_snmp/powernet369.mib
parentInitial commit. (diff)
downloadfence-agents-86ed03f8adee56c050c73018537371c230a664a6.tar.xz
fence-agents-86ed03f8adee56c050c73018537371c230a664a6.zip
Adding upstream version 4.12.1.upstream/4.12.1upstream
Signed-off-by: Daniel Baumann <daniel.baumann@progress-linux.org>
Diffstat (limited to 'agents/apc_snmp/powernet369.mib')
-rw-r--r--agents/apc_snmp/powernet369.mib31109
1 files changed, 31109 insertions, 0 deletions
diff --git a/agents/apc_snmp/powernet369.mib b/agents/apc_snmp/powernet369.mib
new file mode 100644
index 0000000..ab948f8
--- /dev/null
+++ b/agents/apc_snmp/powernet369.mib
@@ -0,0 +1,31109 @@
+-- *************************************************************************
+-- AMERICAN POWER CONVERSION PowerNet-MIB
+-- *************************************************************************
+-- Copyright (c) 2005 American Power Conversion, Inc.
+-- PowerNet is a Trademark of American Power Conversion Corp.
+--
+-- Title: APC TOP LEVEL PowerNet MIB
+--
+-- Version : 3.6.9
+--
+-- Generated by script: tomib.awk
+--
+-- Input File: powernetPS.mib
+--
+-- Created: Wednesday, January, 26, 2005
+--
+-- Revision History:
+-- *************************************************************************
+
+-- - v3.2.0 Added functionality for MasterSwitch Plus
+-- - v3.3.0 Added functionality for MX28B (dcDM3) and 3-phase UPS
+-- - v3.3.2 New traps for Symmetra PX UPS
+-- 07/15/01 - v3.4.0 Added transfer switch
+-- - v3.4.3 Added functionality for External and Integrated Environmental Monitor
+-- 06/14/02 - v3.4.4 Added dcmim2(Siemens) branch, Battery Manager(Reading) traps, and
+-- Psx Traps for PDU and RM-PDU and Netlock branch/traps
+-- 06/18/02 - v3.5.0a Sync Control Group support
+-- 08/06/02 - v3.5.0a Environmental Management System branch/traps
+-- 09/16/02 - v3.5.0b Fixed some odds/ends ... going to RM-PDU for MS additions
+-- 09/25/02 - v3.5.0c MS3 additions
+-- 11/05/02 - v3.5.0e More Environmental Management System/A-Link devices(ARU)
+-- 11/22/02 - v3.5.0g Added General APC device status OID
+-- 11/27/02 - v3.5.0h Wrapped up MS3 ((Controlled or Metered) Rack PDU) changes
+-- 12/26/02 - v3.5.1a Changed MS3 name again, Controlled to Switched Rack PDU
+-- 01/07/03 - v3.6.0a Added OIDs/Traps for UPS Switchable Outlet Groups.
+-- 01/09/03 - Adding the General APC device discovery OIDs (hidden)
+-- 01/28/03 - v3.6.0c Made some small trap pair fixes for Switched Rack PDU (MS3)
+-- 02/13/03 - v3.6.0d Mods from the review and some EMS fixes.
+-- Added OID for the new 20kVA Symmetra 3 Phase type.
+-- Added OIDs to upsAdvConfig for Symmetra type UPSs.
+-- Added upsDiagnostics branch OID for Symmetra module information.
+-- 04/05/03 - v3.6.2 Added OID for the new Smart-UPS 7500 and 10000 types.
+-- 06/04/03 - v3.6.3 Added OIDs/Traps for AirFM.
+-- 06/24/03 - v3.6.4 Moved some AirFM temps and humidities from system level to module level.
+-- 10/24/03 - v3.6.4a Added OIDs/Traps for xPDU.
+-- 10/27/03 - v3.6.4f Added AirPA OIDs.
+-- 11/03/03 - v3.6.4g Merge of 3.6.4e and 3.6.4f
+-- 11/07/03 - v3.6.4h Additional review corrections
+-- 12/01/03 - v3.6.5a Added group OIDs for Air FM. Added C & F OIDs for Air PA setpoint.
+-- 12/19/03 - v3.6.5b Review corrections.
+-- 02/23/04 - v3.6.5c Added Modbus to experimental and multiple CB(bank) rPDU support
+-- 05/05/04 - v3.6.6 Adding EMS status OID and trap for H/W issues, redefined duplicate
+-- trap #228 (to ARU Device config change) and minor clean-up
+-- 05/12/04 - v3.6.7a Added Air FM alarm status OIDs.
+-- 06/03/04 - v3.6.7b Added UPS Config for Simple Signal Shutdowns and Number of External
+-- batteries. Added Mute option to the UPS Config Audible Alarm.
+-- 07/12/04 - v3.6.7d Removed Air FM alarm status OIDs due to delay in release.
+-- 07/14/04 - v3.6.7d Added a detailed description to the UPSAdvConfigAlarm OID
+-- 07/14/04 - v3.6.7e Added Custom Event traps
+-- 08/04/04 - v3.6.7 Tag for final builds, see v3.6.7 beta build notes for changes
+-- 08/26/04 - v3.6.8a Added new traps for UPS internal over temperature fault and cleared.
+-- 09/01/04 - v3.6.8b Adding new thresholds for EMS probe config & status
+-- 09/08/04 - v3.6.8c Corrections from MIB review.
+-- 09/30/04 - v3.6.8d Added new traps for AIS ^F Message events.
+-- 10/21/04 - v3.6.8e EMS. Added missing traps and new Rate functionality.
+-- 10/22/04 - v3.6.8f Added resetNetworkLeaveModeAndRestart option to the mcontrolRestartAgent OID.
+-- 10/28/04 - v3.6.8g Updated EMS sections from mib committee review.
+-- 11/22/04 - v3.6.8 Tag for final build.
+-- 12/02/04 - v3.6.9a Added OIDs and traps for BMS-HVA.
+-- 12/20/04 - v3.6.9c corrections to xPDU.
+-- 12/20/04 - v3.6.9c added OIDs and traps for xATS.
+-- 01/03/05 - v3.6.9d removed traps for xATS.
+-- 01/03/05 - v3.6.9e correction to xATS entries, that removed underscores (mib browser incompatibility)
+-- 01/07/05 - v3.6.9f
+-- 01/14/05 - v3.6.9g add xPDU OIDs and traps and some corrections.
+-- 01/14/05 - v3.6.9g modifications to xATS OIDs and traps.
+
+-- *************************************************************************
+-- *************************************************************************
+-- PowerNet-MIB { iso org(3) dod(6) internet(1) private(4)
+-- enterprises(1) apc(318) }
+
+PowerNet-MIB DEFINITIONS ::= BEGIN
+
+IMPORTS
+ enterprises, IpAddress, Gauge, TimeTicks FROM RFC1155-SMI
+ DisplayString FROM RFC1213-MIB
+ OBJECT-TYPE FROM RFC-1212
+ TRAP-TYPE FROM RFC-1215;
+
+apc OBJECT IDENTIFIER ::= { enterprises 318 }
+
+products OBJECT IDENTIFIER ::= { apc 1 }
+apcmgmt OBJECT IDENTIFIER ::= { apc 2 }
+
+hardware OBJECT IDENTIFIER ::= { products 1 }
+software OBJECT IDENTIFIER ::= { products 2 }
+system OBJECT IDENTIFIER ::= { products 3 }
+experimental OBJECT IDENTIFIER ::= { products 4 }
+
+mconfig OBJECT IDENTIFIER ::= { apcmgmt 1 }
+mcontrol OBJECT IDENTIFIER ::= { apcmgmt 2 }
+mtrapargs OBJECT IDENTIFIER ::= { apcmgmt 3 }
+mfiletransfer OBJECT IDENTIFIER ::= { apcmgmt 4 }
+
+mconfigClock OBJECT IDENTIFIER ::= { mconfig 6 }
+
+mfiletransferStatus OBJECT IDENTIFIER ::= { mfiletransfer 1 }
+mfiletransferConfig OBJECT IDENTIFIER ::= { mfiletransfer 2 }
+mfiletransferControl OBJECT IDENTIFIER ::= { mfiletransfer 3 }
+
+mfiletransferConfigSettings OBJECT IDENTIFIER ::= { mfiletransferConfig 1 }
+mfiletransferConfigTFTP OBJECT IDENTIFIER ::= { mfiletransferConfig 2 }
+mfiletransferConfigFTP OBJECT IDENTIFIER ::= { mfiletransferConfig 3 }
+
+ups OBJECT IDENTIFIER ::= { hardware 1 }
+measureUps OBJECT IDENTIFIER ::= { hardware 2 }
+miniSNMPadapter OBJECT IDENTIFIER ::= { hardware 3 }
+masterswitch OBJECT IDENTIFIER ::= { hardware 4 }
+masterswitchVM OBJECT IDENTIFIER ::= { hardware 5 }
+masterswitchMSP OBJECT IDENTIFIER ::= { hardware 6 }
+dcDM3 OBJECT IDENTIFIER ::= { hardware 7 }
+automaticTransferSwitch OBJECT IDENTIFIER ::= { hardware 8 }
+dc2 OBJECT IDENTIFIER ::= { hardware 9 }
+environmentalMonitor OBJECT IDENTIFIER ::= { hardware 10 }
+netlock OBJECT IDENTIFIER ::= { hardware 11 }
+rPDU OBJECT IDENTIFIER ::= { hardware 12 }
+airConditioners OBJECT IDENTIFIER ::= { hardware 13 }
+rARU OBJECT IDENTIFIER ::= { hardware 14 }
+xPDU OBJECT IDENTIFIER ::= { hardware 15 }
+battMan OBJECT IDENTIFIER ::= { hardware 16 }
+xATS OBJECT IDENTIFIER ::= { hardware 17 }
+generator OBJECT IDENTIFIER ::= { hardware 18 }
+
+powerNetSubAgent OBJECT IDENTIFIER ::= { software 1 }
+
+powerNetSoftwareSystem OBJECT IDENTIFIER ::= { powerNetSubAgent 1 }
+powerNetSoftwareConfig OBJECT IDENTIFIER ::= { powerNetSubAgent 2 }
+
+backUPS OBJECT IDENTIFIER ::= { system 1 }
+smartUPS OBJECT IDENTIFIER ::= { system 2 }
+matrixUPS OBJECT IDENTIFIER ::= { system 3 }
+masterSwitch OBJECT IDENTIFIER ::= { system 4 }
+symmetraUPS OBJECT IDENTIFIER ::= { system 5 }
+dp100E OBJECT IDENTIFIER ::= { system 6 }
+dp300E OBJECT IDENTIFIER ::= { system 7 }
+monitors OBJECT IDENTIFIER ::= { system 8 }
+redundantSwitch OBJECT IDENTIFIER ::= { system 9 }
+dcPower OBJECT IDENTIFIER ::= { system 10 }
+automaticXferSwitch OBJECT IDENTIFIER ::= { system 11 }
+netLock OBJECT IDENTIFIER ::= { system 12 }
+symmetra3PhaseUPS OBJECT IDENTIFIER ::= { system 13 }
+networkAir OBJECT IDENTIFIER ::= { system 14 }
+infraXurePDU OBJECT IDENTIFIER ::= { system 15 }
+ais5000UPS OBJECT IDENTIFIER ::= { system 16 }
+smartUPS3Phase OBJECT IDENTIFIER ::= { system 17 }
+battManager OBJECT IDENTIFIER ::= { system 18 }
+infraXureATS OBJECT IDENTIFIER ::= { system 19 }
+
+battManIdent OBJECT IDENTIFIER ::= { battMan 1 }
+battManSystemCalib OBJECT IDENTIFIER ::= { battMan 2 }
+battManUnitCalib OBJECT IDENTIFIER ::= { battMan 3 }
+battManStringCalib OBJECT IDENTIFIER ::= { battMan 4 }
+battManBatteryCalib OBJECT IDENTIFIER ::= { battMan 5 }
+battManConfig OBJECT IDENTIFIER ::= { battMan 6 }
+battManAlarm OBJECT IDENTIFIER ::= { battMan 7 }
+battManSystemStatus OBJECT IDENTIFIER ::= { battMan 8 }
+battManStringStatus OBJECT IDENTIFIER ::= { battMan 9 }
+battManBatteryStatus OBJECT IDENTIFIER ::= { battMan 10 }
+battManInputContactStatus OBJECT IDENTIFIER ::= { battMan 11 }
+battManControl OBJECT IDENTIFIER ::= { battMan 12 }
+battManTestResults OBJECT IDENTIFIER ::= { battMan 13 }
+
+xPDUIdent OBJECT IDENTIFIER ::= { xPDU 1 }
+xPDUDevice OBJECT IDENTIFIER ::= { xPDU 2 }
+xPDUACMonitoringPoint OBJECT IDENTIFIER ::= { xPDU 3 }
+xPDUCircuitBreakers OBJECT IDENTIFIER ::= { xPDU 4 }
+xPDUInputContacts OBJECT IDENTIFIER ::= { xPDU 5 }
+xPDUOutputRelays OBJECT IDENTIFIER ::= { xPDU 6 }
+xPDUMiscGroup OBJECT IDENTIFIER ::= { xPDU 7 }
+
+xPDUMainInput OBJECT IDENTIFIER ::= { xPDUACMonitoringPoint 1 }
+xPDUBypassInput OBJECT IDENTIFIER ::= { xPDUACMonitoringPoint 2 }
+xPDUUPSInput OBJECT IDENTIFIER ::= { xPDUACMonitoringPoint 3 }
+xPDUSystemOutput OBJECT IDENTIFIER ::= { xPDUACMonitoringPoint 4 }
+xPDUGroundMonitorPoint OBJECT IDENTIFIER ::= { xPDUACMonitoringPoint 5 }
+
+xPDUSystemBreakers OBJECT IDENTIFIER ::= { xPDUCircuitBreakers 1 }
+xPDUBranchBreakers OBJECT IDENTIFIER ::= { xPDUCircuitBreakers 2 }
+
+xATSIdent OBJECT IDENTIFIER ::= { xATS 1 }
+xATSDevice OBJECT IDENTIFIER ::= { xATS 2 }
+xATSSwitch OBJECT IDENTIFIER ::= { xATS 3 }
+xATSACMonitoringPoint OBJECT IDENTIFIER ::= { xATS 4 }
+xATSTesting OBJECT IDENTIFIER ::= { xATS 5 }
+xATSInputContacts OBJECT IDENTIFIER ::= { xATS 6 }
+xATSOutputRelays OBJECT IDENTIFIER ::= { xATS 7 }
+xATSMisc OBJECT IDENTIFIER ::= { xATS 8 }
+
+xATSSwitchStatus OBJECT IDENTIFIER ::= { xATSSwitch 1 }
+xATSSwitchSettings OBJECT IDENTIFIER ::= { xATSSwitch 2 }
+xATSSwitchTimers OBJECT IDENTIFIER ::= { xATSSwitch 3 }
+xATSSwitchBlockMap OBJECT IDENTIFIER ::= { xATSSwitch 4 }
+xATSSwitchStatistics OBJECT IDENTIFIER ::= { xATSSwitch 5 }
+
+xATSSource1 OBJECT IDENTIFIER ::= { xATSACMonitoringPoint 1 }
+xATSSource2 OBJECT IDENTIFIER ::= { xATSACMonitoringPoint 2 }
+xATSSystemOutput OBJECT IDENTIFIER ::= { xATSACMonitoringPoint 3 }
+
+xATSTestingStatus OBJECT IDENTIFIER ::= { xATSTesting 1 }
+xATSTestingResults OBJECT IDENTIFIER ::= { xATSTesting 2 }
+xATSTestingSchedule OBJECT IDENTIFIER ::= { xATSTesting 3 }
+xATSTestingSimulatePowerFail OBJECT IDENTIFIER ::= { xATSTesting 4 }
+
+xATSGenerator OBJECT IDENTIFIER ::= { generator 1 }
+
+xATSGeneratorIdent OBJECT IDENTIFIER ::= { xATSGenerator 1 }
+xATSGeneratorStatus OBJECT IDENTIFIER ::= { xATSGenerator 2 }
+xATSGeneratorAdvStatus OBJECT IDENTIFIER ::= { xATSGenerator 3 }
+xATSGeneratorOutput OBJECT IDENTIFIER ::= { xATSGenerator 4 }
+xATSGeneratorSettings OBJECT IDENTIFIER ::= { xATSGenerator 5 }
+xATSGeneratorService OBJECT IDENTIFIER ::= { xATSGenerator 6 }
+xATSGeneratorFuelSystem OBJECT IDENTIFIER ::= { xATSGenerator 7 }
+
+
+smartUPS250 OBJECT IDENTIFIER ::= { smartUPS 1 }
+smartUPS400 OBJECT IDENTIFIER ::= { smartUPS 2 }
+smartUPS600 OBJECT IDENTIFIER ::= { smartUPS 3 }
+smartUPS900 OBJECT IDENTIFIER ::= { smartUPS 4 }
+smartUPS1250 OBJECT IDENTIFIER ::= { smartUPS 5 }
+smartUPS2000 OBJECT IDENTIFIER ::= { smartUPS 6 }
+
+smartUPS450 OBJECT IDENTIFIER ::= { smartUPS 7 }
+smartUPS700 OBJECT IDENTIFIER ::= { smartUPS 8 }
+smartUPS1000 OBJECT IDENTIFIER ::= { smartUPS 9 }
+smartUPS1400 OBJECT IDENTIFIER ::= { smartUPS 10 }
+smartUPS2200 OBJECT IDENTIFIER ::= { smartUPS 11 }
+smartUPS3000 OBJECT IDENTIFIER ::= { smartUPS 12 }
+smartUPS5000 OBJECT IDENTIFIER ::= { smartUPS 13 }
+smartUPS7500 OBJECT IDENTIFIER ::= { smartUPS 14 }
+smartUPS10000 OBJECT IDENTIFIER ::= { smartUPS 15 }
+smartUPS1500 OBJECT IDENTIFIER ::= { smartUPS 16 }
+
+matrixUPS3000 OBJECT IDENTIFIER ::= { matrixUPS 1 }
+matrixUPS5000 OBJECT IDENTIFIER ::= { matrixUPS 2 }
+
+masterSwitchV1 OBJECT IDENTIFIER ::= { masterSwitch 1}
+masterSwitchV2 OBJECT IDENTIFIER ::= { masterSwitch 2}
+masterSwitchVM OBJECT IDENTIFIER ::= { masterSwitch 3}
+masterSwitchMSP OBJECT IDENTIFIER ::= { masterSwitch 4}
+masterSwitchrPDU OBJECT IDENTIFIER ::= { masterSwitch 5}
+
+symmetraUPS4kVA OBJECT IDENTIFIER ::= { symmetraUPS 1 }
+symmetraUPS8kVA OBJECT IDENTIFIER ::= { symmetraUPS 2 }
+symmetraUPS12kVA OBJECT IDENTIFIER ::= { symmetraUPS 3 }
+symmetraUPS16kVA OBJECT IDENTIFIER ::= { symmetraUPS 4 }
+
+environmental OBJECT IDENTIFIER ::= { monitors 1 }
+environmentalMgtSystem OBJECT IDENTIFIER ::= { monitors 2 }
+emu2 OBJECT IDENTIFIER ::= { monitors 3 }
+
+dm3 OBJECT IDENTIFIER ::= { dcPower 1 }
+dcmim2 OBJECT IDENTIFIER ::= { dcPower 2 }
+
+symmetra3PhaseUPS40kVA OBJECT IDENTIFIER ::= { symmetra3PhaseUPS 1 }
+symmetra3PhaseUPS60kVA OBJECT IDENTIFIER ::= { symmetra3PhaseUPS 2 }
+symmetra3PhaseUPS80kVA OBJECT IDENTIFIER ::= { symmetra3PhaseUPS 3 }
+symmetra3PhaseUPS20kVA OBJECT IDENTIFIER ::= { symmetra3PhaseUPS 4 }
+
+airFMSeries OBJECT IDENTIFIER ::= { networkAir 1 }
+rackAirRemovalUnit OBJECT IDENTIFIER ::= { networkAir 2 }
+airPASeries OBJECT IDENTIFIER ::= { networkAir 3 }
+
+ais5000UPS10kVA OBJECT IDENTIFIER ::= { ais5000UPS 1 }
+ais5000UPS20kVA OBJECT IDENTIFIER ::= { ais5000UPS 2 }
+ais5000UPS30kVA OBJECT IDENTIFIER ::= { ais5000UPS 3 }
+ais5000UPS40kVA OBJECT IDENTIFIER ::= { ais5000UPS 4 }
+ais5000UPS60kVA OBJECT IDENTIFIER ::= { ais5000UPS 5 }
+ais5000UPS80kVA OBJECT IDENTIFIER ::= { ais5000UPS 6 }
+ais5000UPS100kVA OBJECT IDENTIFIER ::= { ais5000UPS 7 }
+
+smartUPS3Phase10kVA OBJECT IDENTIFIER ::= { smartUPS3Phase 1 }
+smartUPS3Phase15kVA OBJECT IDENTIFIER ::= { smartUPS3Phase 2 }
+smartUPS3Phase20kVA OBJECT IDENTIFIER ::= { smartUPS3Phase 3 }
+smartUPS3Phase30kVA OBJECT IDENTIFIER ::= { smartUPS3Phase 4 }
+smartUPS3Phase40kVA OBJECT IDENTIFIER ::= { smartUPS3Phase 5 }
+
+upsIdent OBJECT IDENTIFIER ::= { ups 1 }
+upsBattery OBJECT IDENTIFIER ::= { ups 2 }
+upsInput OBJECT IDENTIFIER ::= { ups 3 }
+upsOutput OBJECT IDENTIFIER ::= { ups 4 }
+upsConfig OBJECT IDENTIFIER ::= { ups 5 }
+upsControl OBJECT IDENTIFIER ::= { ups 6 }
+upsTest OBJECT IDENTIFIER ::= { ups 7 }
+upsComm OBJECT IDENTIFIER ::= { ups 8 }
+upsPhase OBJECT IDENTIFIER ::= { ups 9 }
+upsSyncCtrlGroup OBJECT IDENTIFIER ::= { ups 10 }
+upsState OBJECT IDENTIFIER ::= { ups 11 }
+upsOutletGroups OBJECT IDENTIFIER ::= { ups 12 }
+upsDiagnostics OBJECT IDENTIFIER ::= { ups 13 }
+
+upsBasicIdent OBJECT IDENTIFIER ::= { upsIdent 1 }
+upsAdvIdent OBJECT IDENTIFIER ::= { upsIdent 2 }
+
+upsBasicBattery OBJECT IDENTIFIER ::= { upsBattery 1 }
+upsAdvBattery OBJECT IDENTIFIER ::= { upsBattery 2 }
+
+upsBasicInput OBJECT IDENTIFIER ::= { upsInput 1 }
+upsAdvInput OBJECT IDENTIFIER ::= { upsInput 2 }
+
+upsBasicOutput OBJECT IDENTIFIER ::= { upsOutput 1 }
+upsAdvOutput OBJECT IDENTIFIER ::= { upsOutput 2 }
+
+upsBasicConfig OBJECT IDENTIFIER ::= { upsConfig 1 }
+upsAdvConfig OBJECT IDENTIFIER ::= { upsConfig 2 }
+
+upsBasicControl OBJECT IDENTIFIER ::= { upsControl 1 }
+upsAdvControl OBJECT IDENTIFIER ::= { upsControl 2 }
+
+upsBasicTest OBJECT IDENTIFIER ::= { upsTest 1 }
+upsAdvTest OBJECT IDENTIFIER ::= { upsTest 2 }
+
+upsPhaseResetValues OBJECT IDENTIFIER ::= { upsPhase 1 }
+upsPhaseInput OBJECT IDENTIFIER ::= { upsPhase 2 }
+upsPhaseOutput OBJECT IDENTIFIER ::= { upsPhase 3 }
+
+upsSyncCtrlGroupConfig OBJECT IDENTIFIER ::= { upsSyncCtrlGroup 1 }
+upsSyncCtrlGroupStatus OBJECT IDENTIFIER ::= { upsSyncCtrlGroup 2 }
+
+upsBasicState OBJECT IDENTIFIER ::= { upsState 1 }
+upsAdvState OBJECT IDENTIFIER ::= { upsState 2 }
+
+upsOutletGroupStatus OBJECT IDENTIFIER ::= { upsOutletGroups 1 }
+upsOutletGroupConfig OBJECT IDENTIFIER ::= { upsOutletGroups 2 }
+upsOutletGroupControl OBJECT IDENTIFIER ::= { upsOutletGroups 3 }
+
+upsDiagnosticIM OBJECT IDENTIFIER ::= { upsDiagnostics 1 }
+upsDiagnosticPowerModules OBJECT IDENTIFIER ::= { upsDiagnostics 2 }
+upsDiagnosticBatteries OBJECT IDENTIFIER ::= { upsDiagnostics 3 }
+upsDiagnosticSubsystem OBJECT IDENTIFIER ::= { upsDiagnostics 4 }
+upsDiagnosticExternalDevices OBJECT IDENTIFIER ::= { upsDiagnostics 5 }
+upsDiagnosticComBus OBJECT IDENTIFIER ::= { upsDiagnostics 6 }
+
+upsDiagSwitchGear OBJECT IDENTIFIER ::= { upsDiagnosticExternalDevices 1 }
+upsDiagMCCBBox OBJECT IDENTIFIER ::= { upsDiagnosticExternalDevices 2 }
+upsDiagTransformer OBJECT IDENTIFIER ::= { upsDiagnosticExternalDevices 3 }
+
+mUpsEnviron OBJECT IDENTIFIER ::= { measureUps 1 }
+mUpsContact OBJECT IDENTIFIER ::= { measureUps 2 }
+
+serialPort OBJECT IDENTIFIER ::= { miniSNMPadapter 1}
+
+serialPort1 OBJECT IDENTIFIER ::= { serialPort 1}
+serialPort2 OBJECT IDENTIFIER ::= { serialPort 2}
+
+serialPort2Config OBJECT IDENTIFIER ::= { serialPort2 1}
+serialPort2Control OBJECT IDENTIFIER ::= { serialPort2 2}
+
+sPDUIdent OBJECT IDENTIFIER ::= { masterswitch 1 }
+sPDUMasterControl OBJECT IDENTIFIER ::= { masterswitch 2 }
+sPDUMasterConfig OBJECT IDENTIFIER ::= { masterswitch 3 }
+sPDUOutletControl OBJECT IDENTIFIER ::= { masterswitch 4 }
+sPDUOutletConfig OBJECT IDENTIFIER ::= { masterswitch 5 }
+
+sPDUIdentVM OBJECT IDENTIFIER ::= { masterswitchVM 1 }
+sPDUMasterControlVM OBJECT IDENTIFIER ::= { masterswitchVM 2 }
+sPDUMasterConfigVM OBJECT IDENTIFIER ::= { masterswitchVM 3 }
+sPDUMasterStatusVM OBJECT IDENTIFIER ::= { masterswitchVM 4 }
+sPDUOutletControlVM OBJECT IDENTIFIER ::= { masterswitchVM 5 }
+sPDUOutletConfigVM OBJECT IDENTIFIER ::= { masterswitchVM 6 }
+sPDUOutletStatusVM OBJECT IDENTIFIER ::= { masterswitchVM 7 }
+
+sPDUIdentMSP OBJECT IDENTIFIER ::= { masterswitchMSP 1 }
+sPDUMasterControlMSP OBJECT IDENTIFIER ::= { masterswitchMSP 2 }
+sPDUMasterConfigMSP OBJECT IDENTIFIER ::= { masterswitchMSP 3 }
+sPDUMasterStatusMSP OBJECT IDENTIFIER ::= { masterswitchMSP 4 }
+sPDUOutletControlMSP OBJECT IDENTIFIER ::= { masterswitchMSP 5 }
+sPDUOutletConfigMSP OBJECT IDENTIFIER ::= { masterswitchMSP 6 }
+sPDUOutletStatusMSP OBJECT IDENTIFIER ::= { masterswitchMSP 7 }
+
+sPDUOutletConfigMSPall OBJECT IDENTIFIER ::= { sPDUOutletConfigMSP 1 }
+sPDUOutletConfigMSPgs OBJECT IDENTIFIER ::= { sPDUOutletConfigMSP 2 }
+sPDUOutletConfigMSPannun OBJECT IDENTIFIER ::= { sPDUOutletConfigMSP 3 }
+sPDUOutletConfigMSPmups OBJECT IDENTIFIER ::= { sPDUOutletConfigMSP 4 }
+
+rPDUIdent OBJECT IDENTIFIER ::= { rPDU 1 }
+rPDULoad OBJECT IDENTIFIER ::= { rPDU 2 }
+rPDUOutlet OBJECT IDENTIFIER ::= { rPDU 3 }
+rPDUPowerSupply OBJECT IDENTIFIER ::= { rPDU 4 }
+
+rPDULoadDevice OBJECT IDENTIFIER ::= { rPDULoad 1 }
+rPDULoadPhaseConfig OBJECT IDENTIFIER ::= { rPDULoad 2 }
+rPDULoadStatus OBJECT IDENTIFIER ::= { rPDULoad 3 }
+rPDULoadBankConfig OBJECT IDENTIFIER ::= { rPDULoad 4 }
+
+rPDUOutletDevice OBJECT IDENTIFIER ::= { rPDUOutlet 1 }
+rPDUOutletPhase OBJECT IDENTIFIER ::= { rPDUOutlet 2 }
+rPDUOutletControl OBJECT IDENTIFIER ::= { rPDUOutlet 3 }
+rPDUOutletConfig OBJECT IDENTIFIER ::= { rPDUOutlet 4 }
+rPDUOutletStatus OBJECT IDENTIFIER ::= { rPDUOutlet 5 }
+rPDUOutletBank OBJECT IDENTIFIER ::= { rPDUOutlet 6 }
+
+rPDUPowerSupplyDevice OBJECT IDENTIFIER ::= { rPDUPowerSupply 1 }
+
+dm3Ident OBJECT IDENTIFIER ::= { dcDM3 1 }
+dm3Config OBJECT IDENTIFIER ::= { dcDM3 2 }
+dm3Status OBJECT IDENTIFIER ::= { dcDM3 3 }
+
+dm3IdentSystem OBJECT IDENTIFIER ::= { dm3Ident 1}
+
+dm3ConfigSystem OBJECT IDENTIFIER ::= { dm3Config 1 }
+dm3ConfigLVD OBJECT IDENTIFIER ::= { dm3Config 2 }
+dm3ConfigBattery OBJECT IDENTIFIER ::= { dm3Config 3 }
+dm3ConfigPowerModules OBJECT IDENTIFIER ::= { dm3Config 4 }
+dm3ConfigRelays OBJECT IDENTIFIER ::= { dm3Config 5 }
+dm3ConfigDistribution OBJECT IDENTIFIER ::= { dm3Config 6 }
+
+dm3ConfigRectifier OBJECT IDENTIFIER ::= { dm3ConfigPowerModules 1 }
+dm3ConfigConverter OBJECT IDENTIFIER ::= { dm3ConfigPowerModules 2 }
+
+dm3ConfigRectThresh OBJECT IDENTIFIER ::= { dm3ConfigRectifier 1 }
+dm3ConfigRectAlarms OBJECT IDENTIFIER ::= { dm3ConfigRectifier 2 }
+
+dm3ConfigConvThresh OBJECT IDENTIFIER ::= { dm3ConfigConverter 1 }
+dm3ConfigConvAlarms OBJECT IDENTIFIER ::= { dm3ConfigConverter 2 }
+
+dm3ConfigOutputRelays OBJECT IDENTIFIER ::= { dm3ConfigRelays 1 }
+dm3ConfigInputRelays OBJECT IDENTIFIER ::= { dm3ConfigRelays 2 }
+
+dm3ConfigBreakers OBJECT IDENTIFIER ::= { dm3ConfigDistribution 1 }
+dm3ConfigFuses OBJECT IDENTIFIER ::= { dm3ConfigDistribution 2 }
+
+dm3StatusSystem OBJECT IDENTIFIER ::= { dm3Status 1 }
+dm3StatusAlarms OBJECT IDENTIFIER ::= { dm3Status 2 }
+dm3StatusBattery OBJECT IDENTIFIER ::= { dm3Status 3 }
+dm3StatusOEM OBJECT IDENTIFIER ::= { dm3Status 4 }
+dm3StatusLVD OBJECT IDENTIFIER ::= { dm3Status 5 }
+dm3StatusPowerModules OBJECT IDENTIFIER ::= { dm3Status 6 }
+dm3StatusRelays OBJECT IDENTIFIER ::= { dm3Status 7 }
+dm3StatusDistribution OBJECT IDENTIFIER ::= { dm3Status 8 }
+
+dm3StatusRectifier OBJECT IDENTIFIER ::= { dm3StatusPowerModules 1 }
+dm3StatusConverter OBJECT IDENTIFIER ::= { dm3StatusPowerModules 2 }
+
+dm3StatusOutputRelays OBJECT IDENTIFIER ::= { dm3StatusRelays 1 }
+dm3StatusInputRelays OBJECT IDENTIFIER ::= { dm3StatusRelays 2 }
+
+dm3StatusBreakers OBJECT IDENTIFIER ::= { dm3StatusDistribution 1 }
+dm3StatusFuses OBJECT IDENTIFIER ::= { dm3StatusDistribution 2 }
+
+atsIdent OBJECT IDENTIFIER ::= { automaticTransferSwitch 1 }
+atsCalibration OBJECT IDENTIFIER ::= { automaticTransferSwitch 2 }
+atsControl OBJECT IDENTIFIER ::= { automaticTransferSwitch 3 }
+atsConfig OBJECT IDENTIFIER ::= { automaticTransferSwitch 4 }
+atsStatus OBJECT IDENTIFIER ::= { automaticTransferSwitch 5 }
+
+atsCalibrationInput OBJECT IDENTIFIER ::= { atsCalibration 1 }
+atsCalibrationPowerSupply OBJECT IDENTIFIER ::= { atsCalibration 2 }
+atsCalibrationOutput OBJECT IDENTIFIER ::= { atsCalibration 3 }
+
+atsStatusDeviceStatus OBJECT IDENTIFIER ::= { atsStatus 1 }
+atsStatusResetValues OBJECT IDENTIFIER ::= { atsStatus 2 }
+atsStatusInput OBJECT IDENTIFIER ::= { atsStatus 3 }
+atsStatusOutput OBJECT IDENTIFIER ::= { atsStatus 4 }
+
+dcmim2Ident OBJECT IDENTIFIER ::= { dc2 1 }
+dcmim2Control OBJECT IDENTIFIER ::= { dc2 2 }
+dcmim2Config OBJECT IDENTIFIER ::= { dc2 3 }
+dcmim2Status OBJECT IDENTIFIER ::= { dc2 4 }
+
+dcmim2IdentSystem OBJECT IDENTIFIER ::= { dcmim2Ident 1 }
+
+dcmim2ControlSystem OBJECT IDENTIFIER ::= { dcmim2Control 1 }
+
+dcmim2ConfigSystem OBJECT IDENTIFIER ::= { dcmim2Config 1 }
+dcmim2ConfigBattery OBJECT IDENTIFIER ::= { dcmim2Config 2 }
+dcmim2ConfigLVD OBJECT IDENTIFIER ::= { dcmim2Config 3 }
+
+dcmim2StatusSystem OBJECT IDENTIFIER ::= { dcmim2Status 1 }
+dcmim2StatusRectifier OBJECT IDENTIFIER ::= { dcmim2Status 2 }
+dcmim2StatusBattery OBJECT IDENTIFIER ::= { dcmim2Status 3 }
+dcmim2StatusLVD OBJECT IDENTIFIER ::= { dcmim2Status 4 }
+dcmim2StatusAlarms OBJECT IDENTIFIER ::= { dcmim2Status 5 }
+
+external OBJECT IDENTIFIER ::= { environmentalMonitor 1 }
+integrated OBJECT IDENTIFIER ::= { environmentalMonitor 2 }
+envMgtSystem OBJECT IDENTIFIER ::= { environmentalMonitor 3 }
+
+emIdent OBJECT IDENTIFIER ::= { external 1 }
+emConfig OBJECT IDENTIFIER ::= { external 2 }
+emStatus OBJECT IDENTIFIER ::= { external 3 }
+
+iemIdent OBJECT IDENTIFIER ::= { integrated 1 }
+iemConfig OBJECT IDENTIFIER ::= { integrated 2 }
+iemStatus OBJECT IDENTIFIER ::= { integrated 3 }
+
+emsIdent OBJECT IDENTIFIER ::= { envMgtSystem 1 }
+
+emsOutputRelayControl OBJECT IDENTIFIER ::= { envMgtSystem 2 }
+emsOutletControl OBJECT IDENTIFIER ::= { envMgtSystem 3 }
+emsSensorControl OBJECT IDENTIFIER ::= { envMgtSystem 4 }
+emsAlarmDeviceControl OBJECT IDENTIFIER ::= { envMgtSystem 5 }
+
+emsConfig OBJECT IDENTIFIER ::= { envMgtSystem 6 }
+emsProbeConfig OBJECT IDENTIFIER ::= { envMgtSystem 7 }
+emsInputContactConfig OBJECT IDENTIFIER ::= { envMgtSystem 8 }
+emsOutputRelayConfig OBJECT IDENTIFIER ::= { envMgtSystem 9 }
+emsOutletConfig OBJECT IDENTIFIER ::= { envMgtSystem 10 }
+emsSensorConfig OBJECT IDENTIFIER ::= { envMgtSystem 11 }
+
+emsStatus OBJECT IDENTIFIER ::= { envMgtSystem 12 }
+emsProbeStatus OBJECT IDENTIFIER ::= { envMgtSystem 13 }
+emsInputContactStatus OBJECT IDENTIFIER ::= { envMgtSystem 14 }
+emsOutputRelayStatus OBJECT IDENTIFIER ::= { envMgtSystem 15 }
+emsOutletStatus OBJECT IDENTIFIER ::= { envMgtSystem 16 }
+emsAlarmDeviceStatus OBJECT IDENTIFIER ::= { envMgtSystem 17 }
+emsSensorStatus OBJECT IDENTIFIER ::= { envMgtSystem 18 }
+
+nlIdent OBJECT IDENTIFIER ::= { netlock 1 }
+nlStatus OBJECT IDENTIFIER ::= { netlock 2 }
+
+airFM OBJECT IDENTIFIER ::= { airConditioners 1 }
+airFMIdent OBJECT IDENTIFIER ::= { airFM 1 }
+airFMStatus OBJECT IDENTIFIER ::= { airFM 2 }
+airFMGroup OBJECT IDENTIFIER ::= { airFM 3 }
+
+airPA OBJECT IDENTIFIER ::= { airConditioners 2 }
+airPAIdent OBJECT IDENTIFIER ::= { airPA 1 }
+airPAStatus OBJECT IDENTIFIER ::= { airPA 2 }
+
+rARUIdent OBJECT IDENTIFIER ::= { rARU 1 }
+rARUConfig OBJECT IDENTIFIER ::= { rARU 2 }
+rARUStatus OBJECT IDENTIFIER ::= { rARU 3 }
+
+
+-- object types
+
+-- the products group
+-- the experimental group
+
+
+
+-- the apcmgmt group
+-- the mconfig group
+
+mconfigNumTrapReceivers OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of managers to send traps to."
+ ::= { mconfig 1 }
+
+mconfigTrapReceiverTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF MconfigTrapReceiverEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A list of managers to send traps to. The number of
+ entries is given by the value of mconfigNumTrapReceivers.
+ Maximum number of Trap Receivers is four."
+ ::= { mconfig 2 }
+
+mconfigTrapReceiverEntry OBJECT-TYPE
+ SYNTAX MconfigTrapReceiverEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The managers to send traps to."
+ INDEX { trapIndex}
+ ::= { mconfigTrapReceiverTable 1 }
+
+MconfigTrapReceiverEntry ::=
+ SEQUENCE {
+ trapIndex
+ INTEGER,
+ receiverAddr
+ IpAddress,
+ communityString
+ DisplayString,
+ severity
+ INTEGER,
+ acceptThisReceiver
+ INTEGER,
+ receiveTrapType
+ INTEGER
+ }
+
+trapIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to a trap receiver entry."
+ ::= { mconfigTrapReceiverEntry 1 }
+
+receiverAddr OBJECT-TYPE
+ SYNTAX IpAddress
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The IP address of the manager to send a trap to."
+ ::= { mconfigTrapReceiverEntry 2 }
+
+communityString OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The community name to use in the trap when
+ sent to the manager."
+ ::= { mconfigTrapReceiverEntry 3 }
+
+severity OBJECT-TYPE
+ SYNTAX INTEGER {
+ information(1),
+ warning(2),
+ severe(3)
+ }
+ ACCESS read-only
+ STATUS obsolete
+ DESCRIPTION
+ "The severity threshold of traps to send to the manager.
+ traps are labeled in severity as informational(1), warning(2),
+ severe(3). Only traps of equal or greater severity than
+ this value are sent to the manager."
+ ::= { mconfigTrapReceiverEntry 4 }
+
+acceptThisReceiver OBJECT-TYPE
+ SYNTAX INTEGER {
+ yes (1),
+ no (2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "An entry will become active if yes, and will
+ be deleted if no."
+ ::= { mconfigTrapReceiverEntry 5 }
+
+
+receiveTrapType OBJECT-TYPE
+ SYNTAX INTEGER {
+ powernet (1),
+ ietf (2),
+ both (3)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The node in this entry will receive traps defined in APC
+ PowerNet MIB, if this OID is set to yes."
+ ::= { mconfigTrapReceiverEntry 6 }
+
+mconfigBOOTPEnabled OBJECT-TYPE
+ SYNTAX INTEGER {
+ yes (1),
+ no (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The value of yes(1) indicates the PowerNet Adapter is configured to
+ obtain its IP configuration parameters from a BOOTP server.
+
+ The value of no(2) indicates adapter will assume IP configuration parameters
+ values saved in adapter's eeprom, which was originally configured at local
+ console."
+ ::= { mconfig 3 }
+
+mconfigTFTPServerIP OBJECT-TYPE
+ SYNTAX IpAddress
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The IP address of TFTP server. If mconfigBOOTPEnabled is yes(1), then this IP address
+ is provided by BOOTP server and not allowed to be modified; otherwise, this IP address
+ can be modified.
+
+ Before using TFTP to load new code image, the image file should be placed in proper
+ directory of the specified TFTP server. This OID is only supported by AP9605, AP9205,
+ and AP9603 PowerNet SNMP Adapters."
+ ::= { mconfig 4 }
+
+newCodeAuthentViaTFTP OBJECT-TYPE
+ SYNTAX INTEGER {
+ unknown (1),
+ validNewAgentCodeImage (2),
+ sameAgentCodeImage (3),
+ invalidAgentCodeImage (4)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Once mcontrolRestartAgent is set to loadAndExecuteNewAgent (3), PowerNet adapter will
+ start to load the remote image file, for authentication only, instead of saving the code
+ into flash memory. Only if a validNewAgentCodeImage (1) is found will the agent reboot
+ the PowerNet adapter and invoke the loader to load and save new code into the flash memory.
+ Otherwise, the current agent code will continue to run.
+
+ This OID shows the result of the above authentication process.
+ validNewAgentCodeImage (1) means the code image on TFTP server
+ is a valid APC agent code and is different version from the current agent.
+ Once agent identifies this, loader will start to update flash memory with
+ the new agent code.
+
+ sameAgentCodeImage (2) means the code image on TFTP server is exactly the
+ same as the currently running agent. Currently running agent will not invoke
+ loader to load the same again.
+
+ invalidAgentCodeImage (3) means the code image on TFTP server is NOT a valid
+ APC agent code. Thus, current agent will not load it into the flash memory.
+
+ The value of this OID will be associated with TRAP codeImageAuthentDone.
+ This OID is only supported by AP9605, AP9205, and AP9603 PowerNet SNMP Adapters."
+
+ ::= { mconfig 5 }
+
+mconfigClockDate OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The current date in the mm/dd/yyyy format. Example: 01/01/2000."
+ ::= { mconfigClock 1 }
+
+mconfigClockTime OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The current time in the hh:mm:ss am/pm format. Example: 12:00:00 am."
+ ::= { mconfigClock 2 }
+
+mcontrolRestartAgent OBJECT-TYPE
+ SYNTAX INTEGER {
+ restartCurrentAgent (1),
+ continueCurrentAgent (2),
+ loadAndExecuteNewAgent (3),
+ restartWithoutAgent (4),
+ resetNetworkAndRestart (5),
+ resetNetworkLeaveModeAndRestart (6)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Setting this OID to restartCurrentAgent (1) will restart the same SNMP
+ agent code currently saved in flash memory. Setting this OID to
+ loadAndExecuteNewAgent (3) will enable adapter to load a new agent code
+ into the flash memory and start to execute this new agent code.
+ Bootp/tftp is the default protocol. loadAndExecuteNewAgent is only
+ supported by AP9605, AP9205, and AP9603 PowerNet SNMP Adapters. Setting
+ this OID to restartWithoutAgent (4) will restart the system and not
+ start the agent. The subsequent time the system restarts the agent will
+ also automatically restart. Setting this OID to
+ resetNetworkAndRestart (5) will set the Boot Mode, IP Address, Subnet
+ Mask, and Default Gateway to defaults, expire any existing DHCP lease
+ and then restart the system. Setting this OID to
+ resetNetworkLeaveModeAndRestart (6) will leave the Boot Mode at the
+ current setting, set the IP Address, Subnet Mask, and Default Gateway to
+ defaults, expire any existing DHCP lease and then restart the system."
+
+ ::= { mcontrol 1 }
+
+-- The mtrapargs group
+-- These OIDs allows APC traps to be sent with additional arguments
+-- which may not be defined in the APC MIB.
+
+mtrapargsInteger OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This OID allows APC traps to be sent with an integer argument
+ that my not be defined in the APC MIB.
+
+ A get of this OID will return 0."
+ ::= { mtrapargs 1 }
+
+mtrapargsIpAddress OBJECT-TYPE
+ SYNTAX IpAddress
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This OID allows APC traps to be sent with an IP address argument
+ that my not be defined in the APC MIB.
+
+ A get of this OID will return 0.0.0.0."
+ ::= { mtrapargs 2 }
+
+mtrapargsString OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This OID allows APC traps to be sent with an octet string argument
+ that my not be defined in the APC MIB.
+
+ A get of this OID will return a NULL string."
+ ::= { mtrapargs 3 }
+
+mtrapargsGauge OBJECT-TYPE
+ SYNTAX Gauge
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This OID allows APC traps to be sent with a Gauge argument
+ that my not be defined in the APC MIB.
+
+ A get of this OID will return 0."
+ ::= { mtrapargs 4 }
+
+mtrapargsTimeTicks OBJECT-TYPE
+ SYNTAX TimeTicks
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This OID allows APC traps to be sent with a TimeTicks argument
+ that my not be defined in the APC MIB.
+
+ A get of this OID will return 0."
+ ::= { mtrapargs 5 }
+
+mtrapargsInteger02 OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This OID allows APC traps to be sent with an integer argument
+ that my not be defined in the APC MIB.
+
+ A get of this OID will return 0."
+ ::= { mtrapargs 6 }
+
+mtrapargsInteger03 OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This OID allows APC traps to be sent with an integer argument
+ that my not be defined in the APC MIB.
+
+ A get of this OID will return 0."
+ ::= { mtrapargs 7 }
+
+mtrapargsIpAddress02 OBJECT-TYPE
+ SYNTAX IpAddress
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This OID allows APC traps to be sent with an IP address argument
+ that my not be defined in the APC MIB.
+
+ A get of this OID will return 0.0.0.0."
+ ::= { mtrapargs 8 }
+
+mtrapargsIpAddress03 OBJECT-TYPE
+ SYNTAX IpAddress
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This OID allows APC traps to be sent with an IP address argument
+ that my not be defined in the APC MIB.
+
+ A get of this OID will return 0.0.0.0."
+ ::= { mtrapargs 9 }
+
+mtrapargsString02 OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This OID allows APC traps to be sent with an octet string argument
+ that my not be defined in the APC MIB.
+
+ A get of this OID will return a NULL string."
+ ::= { mtrapargs 10 }
+
+mtrapargsString03 OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This OID allows APC traps to be sent with an octet string argument
+ that my not be defined in the APC MIB.
+
+ A get of this OID will return a NULL string."
+ ::= { mtrapargs 11 }
+
+mtrapargsGauge02 OBJECT-TYPE
+ SYNTAX Gauge
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This OID allows APC traps to be sent with a Gauge argument
+ that my not be defined in the APC MIB.
+
+ A get of this OID will return 0."
+ ::= { mtrapargs 12 }
+
+mtrapargsGauge03 OBJECT-TYPE
+ SYNTAX Gauge
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This OID allows APC traps to be sent with a Gauge argument
+ that my not be defined in the APC MIB.
+
+ A get of this OID will return 0."
+ ::= { mtrapargs 13 }
+
+mtrapargsTimeTicks02 OBJECT-TYPE
+ SYNTAX TimeTicks
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This OID allows APC traps to be sent with a TimeTicks argument
+ that my not be defined in the APC MIB.
+
+ A get of this OID will return 0."
+ ::= { mtrapargs 14 }
+
+mtrapargsTimeTicks03 OBJECT-TYPE
+ SYNTAX TimeTicks
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This OID allows APC traps to be sent with a TimeTicks argument
+ that my not be defined in the APC MIB.
+
+ A get of this OID will return 0."
+ ::= { mtrapargs 15 }
+
+-- the mfiletransfer group
+-- the mfiletransferStatus group
+mfiletransferStatusLastTransferResult OBJECT-TYPE
+ SYNTAX INTEGER {
+ lastFileTransferResultSuccessful (1),
+ lastFileTransferResultNotAvailable (2),
+ lastFileTransferResultFailureUnknown (3),
+ lastFileTransferResultFailureServerInaccessible (4),
+ lastFileTransferResultFailureServerAccessDenied (5),
+ lastFileTransferResultFailureFileNotFound (6),
+ lastFileTransferResultFailureFileTypeUnknown (7),
+ lastFileTransferResultFailureFileCorrupted (8)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Once mfiletransferControlInitiateFileTransfer is set to a value other than doNotInitiateFileTransfer
+ a file transfer of mfiletransferConfigSettingsFilename will be attempted from either a TFTP or FTP
+ server.
+
+ This OID shows the last attempted file transfer result.
+ lastFileTransferResultSuccessful (1) means the file transfer was successful.
+ lastFileTransferResultNotAvailable (2) means that there have been no previous file transfers.
+ lastFileTransferResultFailureUnknown (3) means that the last file transfer failed for an unknown reason.
+ lastFileTransferResultFailureServerInaccessible (4) means that the TFTP or FTP server could not be found on the network.
+ lastFileTransferResultFailureServerAccessDenied (5) means that the TFTP or FTP server denied access.
+ lastFileTransferResultFailureFileNotFound (6) means that the file could not be located.
+ lastFileTransferResultFailureFileTypeUnknown (7) means the file was examined, but the contents were unknown.
+ lastFileTransferResultFailureFileCorrupt (8) means the transferred file was corrupt."
+
+ ::= { mfiletransferStatus 1 }
+
+-- the mfiletransferConfig group
+-- the mfiletransferConfigSettings group
+
+mfiletransferConfigSettingsFilename OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The path and name of the file to transfer using the mfiletransferControlInitiateFileTransfer OID.
+ If the file to transfer exists in the default server directory then the path may be omitted."
+
+ ::= { mfiletransferConfigSettings 1 }
+
+-- the mfiletransferConfigTFTP group
+
+mfiletransferConfigTFTPServerAddress OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The IP Address in dotted decimal notation of the TFTP server involved in the file transfer."
+
+ ::= { mfiletransferConfigTFTP 1 }
+
+-- the mfiletransferConfigFTP group
+
+mfiletransferConfigFTPServerAddress OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The IP Address in dotted decimal notation of the FTP server involved in the file transfer."
+
+ ::= { mfiletransferConfigFTP 1 }
+
+mfiletransferConfigFTPServerUser OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The user identification for logging into the FTP server specified with mfiletransferConfigFTPServerAddress."
+
+ ::= { mfiletransferConfigFTP 2 }
+
+mfiletransferConfigFTPServerPassword OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The password for logging into the FTP server specified with mfiletransferConfigFTPServerAddress."
+
+ ::= { mfiletransferConfigFTP 3 }
+
+-- the mfiletransferControl group
+
+mfiletransferControlInitiateFileTransfer OBJECT-TYPE
+ SYNTAX INTEGER {
+ doNotInitiateFileTransfer (1),
+ initiateFileTransferDownloadViaTFTP (2),
+ initiateFileTransferDownloadViaFTP (3)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Setting this OID to doNotInitiateFileTransfer (1) will do nothing.
+
+ Setting this OID to initiateFileTransferDownloadViaTFTP (2) will attempt to transfer the file named in
+ mfiletransferConfigSettingsFilename from the TFTP Server identified in mfiletransferConfigTFTPAddress.
+
+ Setting this OID to initiateFileTransferDownloadViaFTP (3) will attempt to transfer the file named in
+ mfiletransferConfigSettingsFilename from the FTP Server identified in mfiletransferConfigFTPAddress
+ using mfiletransferConfigFTPUser and mfiletransferConfigFTPPassword for the FTP Server login process."
+
+ ::= { mfiletransferControl 1 }
+
+-- the battManIdent group
+
+battManIdentProductName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The name of the battery manager."
+ ::= { battManIdent 1 }
+
+battManIdentHardwareRev OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The battery manager network interface hardware revision.
+ This value is set at the factory."
+ ::= { battManIdent 2 }
+
+battManIdentFirmwareRev OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The battery manager network interface firmware revision.
+ This value is set at the factory and can change with firmware update."
+ ::= { battManIdent 3 }
+
+battManIdentDateOfManufacture OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The date the battery manager was manufactured in mm/dd/yyyy format.
+ This value is set at the factory."
+ ::= { battManIdent 4 }
+
+battManIdentModelNumber OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The battery manager model number character string.
+ This value is set at the factory."
+ ::= { battManIdent 5 }
+
+battManIdentSerialNumber OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The battery manager serial number character string.
+ This value is set at the factory."
+ ::= { battManIdent 6 }
+
+-- the battManCalib group
+-- system calibration
+
+battManOhmicValueCorrectionFactor OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The system ohmic value correction factor in percent."
+ ::= { battManSystemCalib 1 }
+
+-- unit calibration
+
+battManUnitCalibTableSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of entries in the battManUnitCalibTable."
+ ::= { battManUnitCalib 1 }
+
+battManUnitCalibTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF BattManUnitCalibTableEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for getting calibration information from each unit in the system."
+ ::= { battManUnitCalib 2 }
+
+battManUnitCalibTableEntry OBJECT-TYPE
+ SYNTAX BattManUnitCalibTableEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The unit to get data from."
+ INDEX { battManUnitCalibIndex }
+ ::= { battManUnitCalibTable 1 }
+
+BattManUnitCalibTableEntry ::=
+ SEQUENCE {
+ battManUnitCalibIndex INTEGER,
+ battManUnitSerialNumber DisplayString,
+ battManBatteryVoltageZeroCalib INTEGER,
+ battManBatteryVoltageSpanCalib INTEGER
+ }
+
+battManUnitCalibIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Index of unit calibration entries in the table."
+ ::= { battManUnitCalibTableEntry 1 }
+
+battManUnitSerialNumber OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The serial number of the unit."
+ ::= { battManUnitCalibTableEntry 2 }
+
+battManBatteryVoltageZeroCalib OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The unit battery voltage zero calibration in millivolts."
+ ::= { battManUnitCalibTableEntry 3 }
+
+battManBatteryVoltageSpanCalib OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The unit battery voltage span calibration in percent."
+ ::= { battManUnitCalibTableEntry 4 }
+
+-- string calibration table
+
+battManStringCalibTableSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of entries in the battManStringCalibTable."
+ ::= { battManStringCalib 1 }
+
+battManStringCalibTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF BattManStringCalibTableEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for getting calibration information from each string in the system."
+ ::= { battManStringCalib 2 }
+
+battManStringCalibTableEntry OBJECT-TYPE
+ SYNTAX BattManStringCalibTableEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The string to get data from."
+ INDEX { battManStringCalibIndex }
+ ::= { battManStringCalibTable 1 }
+
+BattManStringCalibTableEntry ::=
+ SEQUENCE {
+ battManStringCalibIndex INTEGER,
+ battManDCCurrentZeroCalib INTEGER,
+ battManACCurrentZeroCalib INTEGER,
+ battManProbeRange INTEGER
+ }
+
+battManStringCalibIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Index of string calibration entries in the table."
+ ::= { battManStringCalibTableEntry 1 }
+
+battManDCCurrentZeroCalib OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The string DC current zero calibration in tenths of amps."
+ ::= { battManStringCalibTableEntry 2 }
+
+battManACCurrentZeroCalib OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The string AC current zero calibration in tenths of amps."
+ ::= { battManStringCalibTableEntry 3 }
+
+battManProbeRange OBJECT-TYPE
+ SYNTAX INTEGER {
+ amps1000 (1),
+ amps500 (2),
+ amps100 (3)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The string probe range in amps."
+ ::= { battManStringCalibTableEntry 4 }
+
+--string 1 battery calibration table
+
+battManString1BatteryCalibTableSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of entries in the battManString1BatteryCalibTable."
+ ::= { battManBatteryCalib 1 }
+
+battManString1BatteryCalibTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF BattManString1BatteryCalibTableEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for getting calibration information from each battery in String 1."
+ ::= { battManBatteryCalib 2 }
+
+battManString1BatteryCalibTableEntry OBJECT-TYPE
+ SYNTAX BattManString1BatteryCalibTableEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The string to get data from."
+ INDEX { battManString1BatteryCalibIndex }
+ ::= { battManString1BatteryCalibTable 1 }
+
+BattManString1BatteryCalibTableEntry ::=
+ SEQUENCE {
+ battManString1BatteryCalibIndex INTEGER,
+ battManString1BatteryInterTierOhmicValue INTEGER
+ }
+
+battManString1BatteryCalibIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Index of battery calibration entries in the table."
+ ::= { battManString1BatteryCalibTableEntry 1 }
+
+battManString1BatteryInterTierOhmicValue OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The battery inter-tier ohmic value in ohms. This corresponds to the ohmic
+ value for the positive terminal of the battery."
+ ::= { battManString1BatteryCalibTableEntry 2 }
+
+--string 2 battery calibration table
+
+battManString2BatteryCalibTableSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of entries in the battManString2BatteryCalibTable."
+ ::= { battManBatteryCalib 3 }
+
+battManString2BatteryCalibTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF BattManString2BatteryCalibTableEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for getting calibration information from each battery in String 2."
+ ::= { battManBatteryCalib 4 }
+
+battManString2BatteryCalibTableEntry OBJECT-TYPE
+ SYNTAX BattManString2BatteryCalibTableEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The string to get data from."
+ INDEX { battManString2BatteryCalibIndex }
+ ::= { battManString2BatteryCalibTable 1 }
+
+BattManString2BatteryCalibTableEntry ::=
+ SEQUENCE {
+ battManString2BatteryCalibIndex INTEGER,
+ battManString2BatteryInterTierOhmicValue INTEGER
+ }
+
+battManString2BatteryCalibIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Index of battery calibration entries in the table."
+ ::= { battManString2BatteryCalibTableEntry 1 }
+
+battManString2BatteryInterTierOhmicValue OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The battery inter-tier ohmic value in ohms."
+ ::= { battManString2BatteryCalibTableEntry 2 }
+
+-- the battManConfig group
+
+battManConfigApplication OBJECT-TYPE
+ SYNTAX INTEGER {
+ silcon (1),
+ other (2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The type of application the battery manager is installed on:
+ Silcon(1) Silcon UPS or
+ Other(2) Other UPS/Charger."
+ ::= { battManConfig 1 }
+
+battManConfigBatteryChemistry OBJECT-TYPE
+ SYNTAX INTEGER {
+ leadAcid (1),
+ nickel-Cadmium (2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The battery chemistry of the monitored batteries:
+ LeadAcid(1) Lead Acid or
+ Nickel-Cadmium(2) Nickel-Cadmium."
+ ::= { battManConfig 2 }
+
+battManConfigBatteryAHCapacity OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The amp hour capacity of the monitored batteries 5-2000 AH."
+ ::= { battManConfig 3 }
+
+battManConfigNumberofStrings OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The number of strings in the battery manager system (1 - 2 Silcon)/(1 Other)."
+ ::= { battManConfig 4 }
+
+battManConfigBatteriesperString OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The number of batteries per string."
+ ::= { battManConfig 5 }
+
+battManConfigCellsperBattery OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The number of cells per battery (1 - 6 for lead-acid, 1 - 2 for NiCd."
+ ::= { battManConfig 6 }
+
+battManConfigMinCellVoltage OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The minimum battery cell voltage alarm limit in millivolts DC."
+ ::= { battManConfig 7 }
+
+battManConfigMaxCellVoltage OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The maximum battery cell voltage alarm limit in millivolts DC."
+ ::= { battManConfig 8 }
+
+battManConfigMaxPilotTempF OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The maximum pilot battery temperature alarm limit in tenths of degrees Fahrenheit."
+ ::= { battManConfig 9 }
+
+battManConfigMaxPilotTempC OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The maximum pilot battery temperature alarm limit in tenths of degrees Celcius."
+ ::= { battManConfig 10 }
+
+battManConfigMaxAmbientTempF OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The maximum ambient temperature alarm limit in tenths of degrees Fahrenheit."
+ ::= { battManConfig 11 }
+
+battManConfigMaxAmbientTempC OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The maximum ambient temperature alarm limit in tenths of degrees Celcius."
+ ::= { battManConfig 12 }
+
+battManConfigMinAmbientTempF OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The Minimum Ambient Temperature alarm limit in tenths of degrees Fahrenheit."
+ ::= { battManConfig 13 }
+
+battManConfigMinAmbientTempC OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The Minimum Ambient Temperature alarm limit in tenths of degrees Celcius."
+ ::= { battManConfig 14 }
+
+battManConfigMaxRippleCurrent OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The maximum ripple current alarm limit for the monitored battery
+ strings in percent of AH capacity."
+ ::= { battManConfig 15 }
+
+battManConfigMaxCurrentAcceptanceDeviation OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The maximum current acceptance deviation alarm limit in percentage."
+ ::= { battManConfig 16 }
+
+battManConfigMonitorWireLength OBJECT-TYPE
+ SYNTAX INTEGER {
+ fiftyFeetOrLess (1),
+ moreThanFiftyFeet (2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The monitor wire length:
+ fiftyFeetOrLess (1) indicates that the wire length is less than or equal to 50 feet.
+ moreThanFiftyFeet (2) indicates that the wire length is greater than 50 feet."
+ ::= { battManConfig 17 }
+
+battManConfigDischargeVoltageAlarmLevel OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The discharge voltage alarm level in percent."
+ ::= { battManConfig 18 }
+
+battManConfigAutoAnnunciatorReset OBJECT-TYPE
+ SYNTAX INTEGER {
+ disabled (1),
+ enabled (2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The annunciator output signal reset method:
+ disabled(1) means the annunciator signal output will be reset when the reset button is pressed.
+ enabled(2) means the annunciator will stop signalling when all alarm conditions clear."
+ ::= { battManConfig 19 }
+
+-- the battManAlarm group
+
+battManAlarmManagementController OBJECT-TYPE
+ SYNTAX INTEGER {
+ normal (1),
+ alarm (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The Management Controller Alarm is :
+ normal(1) no alarm condtions identified
+ alarm(2) an alarm condition exits."
+ ::= { battManAlarm 1 }
+
+battManAlarmBatteries OBJECT-TYPE
+ SYNTAX INTEGER {
+ normal (1),
+ alarm (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The Batteries Alarm is :
+ normal(1) no alarm condtions identified
+ alarm(2) an alarm condition exits."
+ ::= { battManAlarm 2 }
+
+battManAlarmCharger OBJECT-TYPE
+ SYNTAX INTEGER {
+ normal (1),
+ alarm (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The Charger Alarm is :
+ normal(1) no alarm condtions identified
+ alarm(2) an alarm condition exits."
+ ::= { battManAlarm 3 }
+
+battManAlarmEnvironment OBJECT-TYPE
+ SYNTAX INTEGER {
+ normal (1),
+ alarm (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The Environment Alarm is :
+ normal(1) no alarm condtions identified
+ alarm(2) an alarm condition exits."
+ ::= { battManAlarm 4 }
+
+-- the battManSystemStatus group
+
+-- These are system wide parameters
+
+battManSystemAmbientTempC OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The system ambient temperture in tenths of degrees Celcius."
+ ::= { battManSystemStatus 1 }
+
+battManSystemAmbientTempF OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The system ambient temperture in tenths of degrees Fahrenheit."
+ ::= { battManSystemStatus 2 }
+
+battManSystemPilotTempC OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The system pilot temperature in tenths of degrees Celcius."
+ ::= { battManSystemStatus 3 }
+
+battManSystemPilotTempF OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The system pilot temperature in tenths of degrees Fahrenheit."
+ ::= { battManSystemStatus 4 }
+
+battManSystemAmbientHighTempAlarm OBJECT-TYPE
+ SYNTAX INTEGER {
+ normal (1),
+ alarm (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "When set to alarm(2), indicates that the system has a high temperature alarm."
+ ::= { battManSystemStatus 5 }
+
+battManSystemAmbientLowTempAlarm OBJECT-TYPE
+ SYNTAX INTEGER {
+ normal (1),
+ alarm (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "When set to alarm(2), indicates that the system has a low temperature alarm."
+ ::= { battManSystemStatus 6 }
+
+battManSystemPilotBatteryHighTempAlarm OBJECT-TYPE
+ SYNTAX INTEGER {
+ normal (1),
+ alarm (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "When set to alarm(2), indicates that the system has a pilot battery high temperature alarm."
+ ::= { battManSystemStatus 7 }
+
+battManSystemPilotProbeDisconnected OBJECT-TYPE
+ SYNTAX INTEGER {
+ normal (1),
+ alarm (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "When set to alarm(2), indicates that the system pilot probe is disconnected."
+ ::= { battManSystemStatus 8 }
+
+battManSystemAmbientProbeDisconnected OBJECT-TYPE
+ SYNTAX INTEGER {
+ normal (1),
+ alarm (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "When set to alarm(2), indicates that the system ambient probe is disconnected."
+ ::= { battManSystemStatus 9 }
+
+-- This is a table of input contact parameters
+
+battManInputContactTableSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of entries in the battManContactTable."
+ ::= { battManInputContactStatus 1 }
+
+battManInputContactTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF BattManInputContactTableEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for getting information from each contact
+ in the system. "
+ ::= { battManInputContactStatus 2 }
+
+battManInputContactTableEntry OBJECT-TYPE
+ SYNTAX BattManInputContactTableEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The contact to get data from."
+ INDEX { battManInputContactIndex }
+ ::= { battManInputContactTable 1 }
+
+BattManInputContactTableEntry ::=
+ SEQUENCE {
+ battManInputContactIndex INTEGER,
+ battManInputContactName DisplayString,
+ battManInputContactAlarmState INTEGER,
+ battManInputContactState INTEGER,
+ battManInputContactNormalState INTEGER,
+ battManInputContactAlarmDelay INTEGER
+ }
+
+battManInputContactIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Index of contact entries in the table."
+ ::= { battManInputContactTableEntry 1 }
+
+battManInputContactName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The name of the input contact."
+ ::= { battManInputContactTableEntry 2 }
+
+battManInputContactAlarmState OBJECT-TYPE
+ SYNTAX INTEGER {
+ normal (1),
+ alarm (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "When set to alarm(2), indicates that the alarm condition is active for this contact."
+ ::= { battManInputContactTableEntry 3 }
+
+battManInputContactState OBJECT-TYPE
+ SYNTAX INTEGER {
+ open (1),
+ closed (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "When set to open(1), the input contact is in the open state.
+ When set to closed(2), the input contact is in the closed state."
+ ::= { battManInputContactTableEntry 4 }
+
+battManInputContactNormalState OBJECT-TYPE
+ SYNTAX INTEGER {
+ open (1),
+ closed (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "When set to open(1), the input contact is normally open.
+ When set to closed(2), the input contact is normally closed."
+ ::= { battManInputContactTableEntry 5 }
+
+battManInputContactAlarmDelay OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The alarm delay time in seconds."
+ ::= { battManInputContactTableEntry 6 }
+
+-- This is a table of battery string parameters
+
+battManStringTableSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of entries in the battManStringTable."
+ ::= { battManStringStatus 1 }
+
+battManStringTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF BattManStringTableEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for getting information from each string
+ in the system. "
+ ::= { battManStringStatus 2 }
+
+battManStringTableEntry OBJECT-TYPE
+ SYNTAX BattManStringTableEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The string to get data from."
+ INDEX { battManStringIndex }
+ ::= { battManStringTable 1 }
+
+BattManStringTableEntry ::=
+ SEQUENCE {
+ battManStringIndex INTEGER,
+ battManStringCurrent INTEGER,
+ battManStringRippleCurrent INTEGER,
+ battManStringChargerHighVoltageAlarm INTEGER,
+ battManStringChargerLowVoltageAlarm INTEGER,
+ battManStringCurrentProbeDisconnected INTEGER,
+ battManStringOnBattery INTEGER
+ }
+
+battManStringIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Index of string entries in the table."
+ ::= { battManStringTableEntry 1 }
+
+battManStringCurrent OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The string current in tenths of Amps."
+ ::= { battManStringTableEntry 2 }
+
+battManStringRippleCurrent OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The string ripple current in tenths of Amps."
+ ::= { battManStringTableEntry 3 }
+
+battManStringChargerHighVoltageAlarm OBJECT-TYPE
+ SYNTAX INTEGER {
+ normal (1),
+ alarm (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "When set to alarm(2), indicates that the string charger has a high voltage alarm."
+ ::= { battManStringTableEntry 4 }
+
+battManStringChargerLowVoltageAlarm OBJECT-TYPE
+ SYNTAX INTEGER {
+ normal (1),
+ alarm (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "When set to alarm(2), indicates that the string charger has a low voltage alarm."
+ ::= { battManStringTableEntry 5 }
+
+battManStringCurrentProbeDisconnected OBJECT-TYPE
+ SYNTAX INTEGER {
+ normal (1),
+ alarm (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "When set to alarm(2), indicates that the string charger probe is disconnected."
+ ::= { battManStringTableEntry 6 }
+
+battManStringOnBattery OBJECT-TYPE
+ SYNTAX INTEGER {
+ normal (1),
+ alarm (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "When set to alarm(2), indicates that the string is in the on-battery state."
+ ::= { battManStringTableEntry 7 }
+
+-- the battManString1BatteryStatus group
+
+battManString1BatteryTableSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of entries in the battManString1BatteryStatusTable."
+ ::= { battManBatteryStatus 1 }
+
+battManString1BatteryTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF BattManString1BatteryTableEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for getting information from each string
+ in the system. "
+ ::= { battManBatteryStatus 2 }
+
+battManString1BatteryTableEntry OBJECT-TYPE
+ SYNTAX BattManString1BatteryTableEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The string to get data from."
+ INDEX { battManString1BatteryIndex }
+ ::= { battManString1BatteryTable 1 }
+
+BattManString1BatteryTableEntry ::=
+ SEQUENCE {
+ battManString1BatteryIndex INTEGER,
+ battManString1BatteryVoltage INTEGER,
+ battManString1BatteryLowestVoltage INTEGER,
+ battManString1BatteryCellShorted INTEGER,
+ battManString1BatteryOpenFuseOrConnection INTEGER,
+ battManString1BatteryLowCapacity INTEGER,
+ battManString1BatteryHighOhmicValue INTEGER,
+ battManString1BatteryThermalRunaway INTEGER,
+ battManString1BatteryDryout INTEGER
+ }
+
+battManString1BatteryIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Index of string entries in the table."
+ ::= { battManString1BatteryTableEntry 1 }
+
+battManString1BatteryVoltage OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The battery voltage in milli VDC."
+ ::= { battManString1BatteryTableEntry 2 }
+
+battManString1BatteryLowestVoltage OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The lowest battery discharge voltage during the last power event in milli VDC."
+ ::= { battManString1BatteryTableEntry 3 }
+
+battManString1BatteryCellShorted OBJECT-TYPE
+ SYNTAX INTEGER {
+ normal (1),
+ alarm (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "When set to alarm(2), indicates that a battery cell is shorted."
+ ::= { battManString1BatteryTableEntry 4 }
+
+battManString1BatteryOpenFuseOrConnection OBJECT-TYPE
+ SYNTAX INTEGER {
+ normal (1),
+ alarm (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "When set to alarm(2), indicates that a fuse or connection is open."
+ ::= { battManString1BatteryTableEntry 5 }
+
+battManString1BatteryLowCapacity OBJECT-TYPE
+ SYNTAX INTEGER {
+ normal (1),
+ alarm (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "When set to alarm(2), indicates a battery has low capacity."
+ ::= { battManString1BatteryTableEntry 6 }
+
+battManString1BatteryHighOhmicValue OBJECT-TYPE
+ SYNTAX INTEGER {
+ normal (1),
+ alarm (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "When set to alarm(2), indicates a battery has a high ohmic value."
+ ::= { battManString1BatteryTableEntry 7 }
+
+battManString1BatteryThermalRunaway OBJECT-TYPE
+ SYNTAX INTEGER {
+ normal (1),
+ alarm (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "When set to alarm(2), indicates a battery has a thermal runaway condition."
+ ::= { battManString1BatteryTableEntry 8 }
+
+battManString1BatteryDryout OBJECT-TYPE
+ SYNTAX INTEGER {
+ normal (1),
+ alarm (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "When set to alarm(2), indicates a battery has a dryout condition."
+ ::= { battManString1BatteryTableEntry 9 }
+
+-- the battManString2BatteryStatus group
+
+battManString2BatteryTableSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of entries in the battManString2BatteryStatusTable."
+ ::= { battManBatteryStatus 3 }
+
+battManString2BatteryTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF BattManString2BatteryTableEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for getting information from each string
+ in the system. "
+ ::= { battManBatteryStatus 4 }
+
+battManString2BatteryTableEntry OBJECT-TYPE
+ SYNTAX BattManString2BatteryTableEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The string to get data from."
+ INDEX { battManString2BatteryIndex }
+ ::= { battManString2BatteryTable 1 }
+
+BattManString2BatteryTableEntry ::=
+ SEQUENCE {
+ battManString2BatteryIndex INTEGER,
+ battManString2BatteryVoltage INTEGER,
+ battManString2BatteryLowestVoltage INTEGER,
+ battManString2BatteryCellShorted INTEGER,
+ battManString2BatteryOpenFuseOrConnection INTEGER,
+ battManString2BatteryLowCapacity INTEGER,
+ battManString2BatteryHighOhmicValue INTEGER,
+ battManString2BatteryThermalRunaway INTEGER,
+ battManString2BatteryDryout INTEGER
+ }
+
+battManString2BatteryIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Index of string entries in the table."
+ ::= { battManString2BatteryTableEntry 1 }
+
+battManString2BatteryVoltage OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The battery voltage in milli VDC."
+ ::= { battManString2BatteryTableEntry 2 }
+
+battManString2BatteryLowestVoltage OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The lowest battery discharge voltage during the last power event in milli VDC."
+ ::= { battManString2BatteryTableEntry 3 }
+
+battManString2BatteryCellShorted OBJECT-TYPE
+ SYNTAX INTEGER {
+ normal (1),
+ alarm (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "When set to alarm(2), indicates that a battery cell is shorted."
+ ::= { battManString2BatteryTableEntry 4 }
+
+battManString2BatteryOpenFuseOrConnection OBJECT-TYPE
+ SYNTAX INTEGER {
+ normal (1),
+ alarm (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "When set to alarm(2), indicates that a fuse or connection is open."
+ ::= { battManString2BatteryTableEntry 5 }
+
+battManString2BatteryLowCapacity OBJECT-TYPE
+ SYNTAX INTEGER {
+ normal (1),
+ alarm (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "When set to alarm(2), indicates a battery has low capacity."
+ ::= { battManString2BatteryTableEntry 6 }
+
+battManString2BatteryHighOhmicValue OBJECT-TYPE
+ SYNTAX INTEGER {
+ normal (1),
+ alarm (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "When set to alarm(2), indicates a battery has a high ohmic value."
+ ::= { battManString2BatteryTableEntry 7 }
+
+battManString2BatteryThermalRunaway OBJECT-TYPE
+ SYNTAX INTEGER {
+ normal (1),
+ alarm (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "When set to alarm(2), indicates a battery has a thermal runaway condition."
+ ::= { battManString2BatteryTableEntry 8 }
+
+battManString2BatteryDryout OBJECT-TYPE
+ SYNTAX INTEGER {
+ normal (1),
+ alarm (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "When set to alarm(2), indicates a battery has a dryout condition."
+ ::= { battManString2BatteryTableEntry 9 }
+
+-- battery manager control group
+battManRemoteAnnunciatorReset OBJECT-TYPE
+ SYNTAX INTEGER {
+ noOperation (1),
+ reset (2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Setting this OID to reset(2) will reset the user interface annunciator.
+ Getting this OID will do nothing and return the noOperation(1) value."
+ ::= { battManControl 1 }
+
+battManResetChargeCurrentDeviationBenchmark OBJECT-TYPE
+ SYNTAX INTEGER {
+ noOperation (1),
+ reset (2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Setting this OID to reset(2) will reset the charge current deviation benchmark.
+ Getting this OID will do nothing and return the noOperation(1) value."
+ ::= { battManControl 2 }
+
+battManResetLowestDischargeVoltages OBJECT-TYPE
+ SYNTAX INTEGER {
+ noOperation (1),
+ reset (2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Setting this OID to reset(2) will reset the lowest discharge voltages.
+ Getting this OID will do nothing and return the noOperation(1) value."
+ ::= { battManControl 3 }
+
+-- the battManTestResults group
+
+--string 1 test results table
+
+battManString1OhmicValueLastDischargeInfo OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Informational text showing the date/time, load, and pilot temperature for the string
+ during the last discharge when ohmic values were recorded."
+ ::= { battManTestResults 1 }
+
+battManString1OhmicValueTableSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of entries in the battManString1OhmicValueTable."
+ ::= { battManTestResults 2 }
+
+battManString1OhmicValueTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF BattManString1OhmicValueTableEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for getting ohmic value information from each battery in String 1."
+ ::= { battManTestResults 3 }
+
+battManString1OhmicValueTableEntry OBJECT-TYPE
+ SYNTAX BattManString1OhmicValueTableEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The string to get data from."
+ INDEX { battManString1OhmicValueIndex }
+ ::= { battManString1OhmicValueTable 1 }
+
+BattManString1OhmicValueTableEntry ::=
+ SEQUENCE {
+ battManString1OhmicValueIndex INTEGER,
+ battManString1OhmicValueData INTEGER
+ }
+
+battManString1OhmicValueIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The battery number."
+ ::= { battManString1OhmicValueTableEntry 1 }
+
+battManString1OhmicValueData OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The battery inter-tier ohmic value in ohms.
+ Note: Negative values are invalid and may indicate faulty calibration
+ of ohmic value correction factors."
+ ::= { battManString1OhmicValueTableEntry 2 }
+
+battManString1ResponseTestChangeTableSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of entries in the battManString1ResponseTestChangeTable."
+ ::= { battManTestResults 4 }
+
+battManString1ResponseTestChangeTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF BattManString1ResponseTestChangeTableEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for getting response test change information from each battery in String 1."
+ ::= { battManTestResults 5 }
+
+battManString1ResponseTestChangeTableEntry OBJECT-TYPE
+ SYNTAX BattManString1ResponseTestChangeTableEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The string to get data from."
+ INDEX { battManString1ResponseTestChangeIndex }
+ ::= { battManString1ResponseTestChangeTable 1 }
+
+BattManString1ResponseTestChangeTableEntry ::=
+ SEQUENCE {
+ battManString1ResponseTestChangeIndex INTEGER,
+ battManString1ResponseTestChangeData INTEGER
+ }
+
+battManString1ResponseTestChangeIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Index of the entries in the table."
+ ::= { battManString1ResponseTestChangeTableEntry 1 }
+
+battManString1ResponseTestChangeData OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The battery response test change in percent."
+ ::= { battManString1ResponseTestChangeTableEntry 2 }
+
+battManString2OhmicValueLastDischargeInfo OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Informational text showing the date/time, load, and pilot temperature for the string
+ during the last discharge when ohmic values were recorded."
+ ::= { battManTestResults 6 }
+
+battManString2OhmicValueTableSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of entries in the battManString2OhmicValueTable."
+ ::= { battManTestResults 7 }
+
+battManString2OhmicValueTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF BattManString2OhmicValueTableEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for getting ohmic value information from each battery in String 1."
+ ::= { battManTestResults 8 }
+
+battManString2OhmicValueTableEntry OBJECT-TYPE
+ SYNTAX BattManString2OhmicValueTableEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The string to get data from."
+ INDEX { battManString2OhmicValueIndex }
+ ::= { battManString2OhmicValueTable 1 }
+
+BattManString2OhmicValueTableEntry ::=
+ SEQUENCE {
+ battManString2OhmicValueIndex INTEGER,
+ battManString2OhmicValueData INTEGER
+ }
+
+battManString2OhmicValueIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Index of battery calibration entries in the table."
+ ::= { battManString2OhmicValueTableEntry 1 }
+
+battManString2OhmicValueData OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The battery inter-tier ohmic value in ohms.
+ Note: Negative values are invalid and may indicate faulty calibration
+ of ohmic value correction factors."
+ ::= { battManString2OhmicValueTableEntry 2 }
+
+battManString2ResponseTestChangeTableSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of entries in the battManString2ResponseTestChangeTable."
+ ::= { battManTestResults 9 }
+
+battManString2ResponseTestChangeTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF BattManString2ResponseTestChangeTableEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for getting response test change information from each battery in String 1."
+ ::= { battManTestResults 10 }
+
+battManString2ResponseTestChangeTableEntry OBJECT-TYPE
+ SYNTAX BattManString2ResponseTestChangeTableEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The string to get data from."
+ INDEX { battManString2ResponseTestChangeIndex }
+ ::= { battManString2ResponseTestChangeTable 1 }
+
+BattManString2ResponseTestChangeTableEntry ::=
+ SEQUENCE {
+ battManString2ResponseTestChangeIndex INTEGER,
+ battManString2ResponseTestChangeData INTEGER
+ }
+
+battManString2ResponseTestChangeIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Index of the entries in the table."
+ ::= { battManString2ResponseTestChangeTableEntry 1 }
+
+battManString2ResponseTestChangeData OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The battery response test change in percent."
+ ::= { battManString2ResponseTestChangeTableEntry 2 }
+
+-- the xPDUIdent group
+
+xPDUIdentProductName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The name of the PDU."
+ ::= { xPDUIdent 1 }
+
+xPDUIdentHardwareRev OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The hardware revision of the PDU.
+ This value is set at the factory."
+ ::= { xPDUIdent 2 }
+
+xPDUIdentFirmwareAppRev OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "An ID string identifying the application firmware revision of the PDU."
+ ::= { xPDUIdent 3 }
+
+xPDUIdentFirmwareAppOSRev OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "An ID string identifying the application operating system firmware revision of the PDU."
+ ::= { xPDUIdent 4 }
+
+xPDUIdentFirmwareControllerRev OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "An ID string identifying the PDU controller firmware revision."
+ ::= { xPDUIdent 5 }
+
+xPDUIdentDateOfManufacture OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The date when the PDU was manufactured in mm/dd/yyyy format.
+ This value is set at the factory."
+ ::= { xPDUIdent 6 }
+
+xPDUIdentModelNumber OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A character string identifying the model number of
+ the PDU. This value is set at the factory."
+ ::= { xPDUIdent 7 }
+
+xPDUIdentSerialNumber OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A character string identifying the serial number of
+ the PDU. This value is set at the factory."
+ ::= { xPDUIdent 8 }
+
+-- the xPDUDevice group
+
+xPDUDeviceNominalMainInputVoltage OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The nominal main input voltage to the PDU.
+ Measured in Volts, line-to-line for a delta service or
+ line-to-neutral for a wye service."
+ ::= { xPDUDevice 1 }
+
+xPDUDeviceServiceType OBJECT-TYPE
+ SYNTAX INTEGER {
+ delta (1),
+ wye (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The type of utility input to the PDU. Either 3 wires (delta), or 4 wires (wye)."
+ ::= { xPDUDevice 2 }
+
+xPDUDeviceNominalOutputVoltage OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The nominal line-to-neutral output voltage to the load measured in Volts."
+ ::= { xPDUDevice 3 }
+
+xPDUDeviceMainInputBreakerRating OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The rating of the main input breaker measured in Amps."
+ ::= { xPDUDevice 4 }
+
+xPDUDevicePanelBreakerRating OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The rating of the panel breaker measured in Amps."
+ ::= { xPDUDevice 5 }
+
+xPDUDeviceTransformerPresent OBJECT-TYPE
+ SYNTAX INTEGER {
+ notPresent (1),
+ present (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates whether or not a transformer is installed in the PDU."
+ ::= { xPDUDevice 6 }
+
+xPDUDeviceLoadTieBreakerPresent OBJECT-TYPE
+ SYNTAX INTEGER {
+ notPresent (1),
+ present (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates whether or not a load tie breaker is installed in the PDU."
+ ::= { xPDUDevice 7 }
+
+xPDUDeviceLoadTestPortPresent OBJECT-TYPE
+ SYNTAX INTEGER {
+ notPresent (1),
+ present (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates whether or not a load test port is installed in the PDU."
+ ::= { xPDUDevice 8 }
+
+xPDUDeviceFusesPresent OBJECT-TYPE
+ SYNTAX INTEGER {
+ notPresent (1),
+ present (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates whether or not the UPS feed from the PDU includes fuses."
+ ::= { xPDUDevice 9 }
+
+xPDUDeviceFansPresent OBJECT-TYPE
+ SYNTAX INTEGER {
+ notPresent (1),
+ present (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates whether or not cooling fans are installed in the PDU."
+ ::= { xPDUDevice 10 }
+
+xPDUDeviceBypassInputPresent OBJECT-TYPE
+ SYNTAX INTEGER {
+ notPresent (1),
+ present (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates whether or not the PDU is equipped with a second feed for
+ the UPS's bypass input."
+ ::= { xPDUDevice 11 }
+
+xPDUDeviceCrossTieOutputPresent OBJECT-TYPE
+ SYNTAX INTEGER {
+ notPresent (1),
+ present (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates whether or not the PDU is equipped with a cross-tie output."
+ ::= { xPDUDevice 12 }
+
+xPDUDeviceEarthGroundMonitorPresent OBJECT-TYPE
+ SYNTAX INTEGER {
+ notPresent (1),
+ present (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates whether or not the PDU can provide ground current measurements."
+ ::= { xPDUDevice 13 }
+
+xPDUDeviceInfraXureType OBJECT-TYPE
+ SYNTAX INTEGER {
+ typeB (1),
+ typeC (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the configuration of this PDU system.
+ Type-B PDU is in a distributed UPS system and has bypass capabilities.
+ Type-C PDU receives power from a larger central UPS."
+ ::= { xPDUDevice 14 }
+
+-- Main Input
+
+xPDUMainInputOverVoltThreshold OBJECT-TYPE
+ SYNTAX INTEGER (0..30)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Threshold above which an input over voltage condition will be generated.
+ Specified as percent deviation from nominal."
+ ::= { xPDUMainInput 1 }
+
+xPDUMainInputUnderVoltThreshold OBJECT-TYPE
+ SYNTAX INTEGER (0..30)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Threshold below which an input under voltage condition will be generated.
+ Specified as percent deviation from nominal."
+ ::= { xPDUMainInput 2 }
+
+-- Main Input Voltage Table
+
+xPDUMainInputVoltageTableSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of Main input voltage entries."
+ ::= { xPDUMainInput 3 }
+
+xPDUMainInputVoltageTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF XPDUMainInputVoltagePhaseEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A list of input voltage table entries. The number of
+ entries are the phase entries.
+ The number of entries is contained in the
+ xPDUMainInputVoltageTableSize OID."
+ ::= { xPDUMainInput 4 }
+
+ xPDUMainInputVoltagePhaseEntry OBJECT-TYPE
+ SYNTAX XPDUMainInputVoltagePhaseEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "An entry containing information applicable to a
+ particular main input voltage phase."
+ INDEX { xPDUMainInputVoltagePhaseIndex }
+ ::= { xPDUMainInputVoltageTable 1 }
+
+ XPDUMainInputVoltagePhaseEntry ::= SEQUENCE {
+ xPDUMainInputVoltagePhaseIndex INTEGER,
+ xPDUMainInputVoltageLtoL INTEGER,
+ xPDUMainInputVoltageLtoN INTEGER
+ }
+
+ xPDUMainInputVoltagePhaseIndex OBJECT-TYPE
+ SYNTAX INTEGER{
+ phase1(1),
+ phase2(2),
+ phase3(3)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Description of each input phase entry in the table."
+ ::= { xPDUMainInputVoltagePhaseEntry 1 }
+
+ xPDUMainInputVoltageLtoL OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Line-to-line PDU input voltage when an isolation transformer is present,
+ or -1 if no transformer present in this PDU. Measured in tenths of Volts."
+ ::= { xPDUMainInputVoltagePhaseEntry 2 }
+
+ xPDUMainInputVoltageLtoN OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Line-to-neutral PDU input voltage when an isolation transformer is not present,
+ or -1 if a transformer is present in this PDU. Measured in tenths of Volts."
+ ::= { xPDUMainInputVoltagePhaseEntry 3 }
+
+
+xPDUBypassInputOverVoltThreshold OBJECT-TYPE
+ SYNTAX INTEGER (0..30)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Threshold above which a bypass input over voltage condition will be generated.
+ Specified as percent deviation from nominal."
+ ::= { xPDUBypassInput 1 }
+
+xPDUBypassInputUnderVoltThreshold OBJECT-TYPE
+ SYNTAX INTEGER (0..30)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Threshold below which an bypass input under voltage condition will be generated.
+ Specified as percent deviation from nominal."
+ ::= { xPDUBypassInput 2 }
+
+-- Bypass Input Voltage Table
+
+xPDUBypassInputVoltageTableSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of bypass input voltage entries."
+ ::= { xPDUBypassInput 3 }
+
+xPDUBypassInputVoltageTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF XPDUBypassInputVoltagePhaseEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A list of output table entries. The number of
+ entries are the phase entries.
+ The number of entries is contained in the
+ xPDUBypassInputVoltageTableSize OID."
+ ::= { xPDUBypassInput 4 }
+
+ xPDUBypassInputVoltagePhaseEntry OBJECT-TYPE
+ SYNTAX XPDUBypassInputVoltagePhaseEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "An entry containing information applicable to a
+ particular bypass input voltage phase."
+ INDEX { xPDUBypassInputVoltagePhaseIndex }
+ ::= { xPDUBypassInputVoltageTable 1 }
+
+ XPDUBypassInputVoltagePhaseEntry ::= SEQUENCE {
+ xPDUBypassInputVoltagePhaseIndex INTEGER,
+ xPDUBypassInputVoltageLtoL INTEGER,
+ xPDUBypassInputVoltageLtoN INTEGER
+ }
+
+ xPDUBypassInputVoltagePhaseIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Index of each bypass input phase entry in the table."
+ ::= { xPDUBypassInputVoltagePhaseEntry 1 }
+
+ xPDUBypassInputVoltageLtoL OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Line-to-line bypass input voltage, or -1 if no bypass
+ feed is present in this PDU. Measured in tenths of Volts"
+ ::= { xPDUBypassInputVoltagePhaseEntry 2 }
+
+ xPDUBypassInputVoltageLtoN OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Line-to-neutral bypass input voltage, or -1 if no bypass
+ feed is present in this PDU. Measured in tenths of Volts"
+ ::= { xPDUBypassInputVoltagePhaseEntry 3 }
+
+-- UPS Input Table
+
+xPDUUPSInputVoltageTableSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of UPS input voltage entries."
+ ::= { xPDUUPSInput 1 }
+
+xPDUUPSInputVoltageTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF XPDUUPSInputVoltagePhaseEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A list of UPS input table entries. The number of
+ entries are the phase entries.
+ The number of entries is contained in the
+ xPDUUPSInputVoltageTableSize OID."
+ ::= { xPDUUPSInput 2 }
+
+ xPDUUPSInputVoltagePhaseEntry OBJECT-TYPE
+ SYNTAX XPDUUPSInputVoltagePhaseEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "An entry containing information applicable to a
+ particular UPS input voltage phase."
+ INDEX { xPDUUPSInputVoltagePhaseIndex }
+ ::= { xPDUUPSInputVoltageTable 1 }
+
+ XPDUUPSInputVoltagePhaseEntry ::= SEQUENCE {
+ xPDUUPSInputVoltagePhaseIndex INTEGER,
+ xPDUUPSInputVoltageLtoNPresent INTEGER
+ }
+
+ xPDUUPSInputVoltagePhaseIndex OBJECT-TYPE
+ SYNTAX INTEGER{
+ phase1(1),
+ phase2(2),
+ phase3(3)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Description of each UPS input phase entry in the table."
+ ::= { xPDUUPSInputVoltagePhaseEntry 1 }
+
+ xPDUUPSInputVoltageLtoNPresent OBJECT-TYPE
+ SYNTAX INTEGER {
+ notPresent (1),
+ present (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates whether or not voltage is present at the UPS feed."
+ ::= { xPDUUPSInputVoltagePhaseEntry 2 }
+
+-- System Output
+
+xPDUSystemOutputFrequency OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The system output frequency in tenths of Hertz."
+ ::= { xPDUSystemOutput 1 }
+
+xPDUSystemOutputNeutralCurrent OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Shows the neutral current measured at the system output in tenths of Amps."
+ ::= { xPDUSystemOutput 2 }
+
+xPDUSystemOutputTotalPower OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Shows the total system output power in tenths of kW."
+ ::= { xPDUSystemOutput 3 }
+
+xPDUSystemOutputTotalApparentPower OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Shows the total system output power in tenths of kVA."
+ ::= { xPDUSystemOutput 4 }
+
+xPDUSystemOutputTotalPowerFactor OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the total power factor of the system output.
+ A value of 100 representing a unity power factor (1.00).
+ Measured in hundredths."
+ ::= { xPDUSystemOutput 5 }
+
+xPDUSystemOutputFrequencyTolerance OBJECT-TYPE
+ SYNTAX INTEGER{
+ freqToleranceOff (1),
+ freqTolerancePointTwo (2),
+ freqTolerancePointFive (3),
+ freqToleranceOne (4),
+ freqToleranceOnePointFive (5),
+ freqToleranceTwo (6),
+ freqToleranceThree (7),
+ freqToleranceFour (8),
+ freqToleranceFive (9),
+ freqToleranceNine (10)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Shows the circuit panel output frequency tolerance in Hertz."
+ ::= { xPDUSystemOutput 6 }
+
+xPDUSystemOutputMaxKWPower OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Defines 100% load in kW.
+ Purpose is to set to match UPS capabilities."
+ ::= { xPDUSystemOutput 7 }
+
+xPDUSystemOutputOverVoltThreshold OBJECT-TYPE
+ SYNTAX INTEGER (0..30)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Threshold above which an output over voltage condition will be generated.
+ Specified as percent deviation from nominal."
+ ::= { xPDUSystemOutput 8 }
+
+xPDUSystemOutputUnderVoltThreshold OBJECT-TYPE
+ SYNTAX INTEGER (0..30)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Threshold below which an output under voltage condition will be generated.
+ Specified as percent deviation from nominal."
+ ::= { xPDUSystemOutput 9 }
+
+
+xPDUSystemOutputOverCurrentThreshold OBJECT-TYPE
+ SYNTAX INTEGER (0..100)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Threshold above which an over current condition will be generated.
+ Specified as a percent of the panel breaker rating."
+ ::= { xPDUSystemOutput 10 }
+
+xPDUSystemOutputOverCurrentNeutralThreshold OBJECT-TYPE
+ SYNTAX INTEGER (0..100)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Threshold above which an Over current neutral condition will be generated.
+ Specified as a percent of the panel breaker rating."
+ ::= { xPDUSystemOutput 11 }
+
+xPDUSystemOutputUnderCurrentThreshold OBJECT-TYPE
+ SYNTAX INTEGER (0..100)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Threshold below which an under current condition will be generated.
+ Specified as a percent of the panel breaker rating."
+ ::= { xPDUSystemOutput 12 }
+
+xPDUSystemOutputTableSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of System Output phase entries."
+ ::= { xPDUSystemOutput 13 }
+
+xPDUSystemOutputTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF XPDUSystemOutputPhaseEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A list of system output table entries.
+ The number of entries is contained in the
+ xPDUSystemOutputTableSize OID."
+ ::= { xPDUSystemOutput 14 }
+
+ xPDUSystemOutputPhaseEntry OBJECT-TYPE
+ SYNTAX XPDUSystemOutputPhaseEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "An entry containing information applicable to a
+ particular system output phase."
+ INDEX { xPDUSystemOutputPhaseIndex }
+ ::= { xPDUSystemOutputTable 1 }
+
+ XPDUSystemOutputPhaseEntry ::= SEQUENCE {
+ xPDUSystemOutputPhaseIndex INTEGER,
+ xPDUSystemOutputVoltageLtoL INTEGER,
+ xPDUSystemOutputVoltageLtoN INTEGER,
+ xPDUSystemOutputPhaseCurrent INTEGER,
+ xPDUSystemOutputPower INTEGER,
+ xPDUSystemOutputApparentPower INTEGER,
+ xPDUSystemOutputPowerFactor INTEGER
+ }
+
+ xPDUSystemOutputPhaseIndex OBJECT-TYPE
+ SYNTAX INTEGER{
+ phase1(1),
+ phase2(2),
+ phase3(3)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Description of each output phase entry in the table."
+ ::= { xPDUSystemOutputPhaseEntry 1 }
+
+ xPDUSystemOutputVoltageLtoL OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Line-to-line system output voltage available at the cicuit panel.
+ Measured in tenths of Volts."
+ ::= { xPDUSystemOutputPhaseEntry 2 }
+
+ xPDUSystemOutputVoltageLtoN OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Line-to-neutral system output voltage available at the cicuit panel.
+ Measured in tenths of Volts."
+ ::= { xPDUSystemOutputPhaseEntry 3 }
+
+
+ xPDUSystemOutputPhaseCurrent OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "System load current per phase. Measured in tenths of Amps."
+ ::= { xPDUSystemOutputPhaseEntry 4 }
+
+ xPDUSystemOutputPower OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "System output power per phase. Measured in tenths of kW."
+ ::= { xPDUSystemOutputPhaseEntry 5 }
+
+ xPDUSystemOutputApparentPower OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "System output power per phase. Measured in tenths of kVA."
+ ::= { xPDUSystemOutputPhaseEntry 6 }
+
+ xPDUSystemOutputPowerFactor OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the Power Factor of the system output per phase.
+ A value of 100 representing a unity Power Factor (1.00).
+ Measured in hundredths."
+ ::= { xPDUSystemOutputPhaseEntry 7 }
+
+xPDUGroundCurrent OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Shows the current measured in the earth ground conductor in tenths of Amps."
+ ::= { xPDUGroundMonitorPoint 1 }
+
+xPDUGroundCurrentThreshold OBJECT-TYPE
+ SYNTAX INTEGER (0..50)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Threshold above which a ground current over current
+ condition will be generated. Measured in tenths of Amps."
+ ::= { xPDUGroundMonitorPoint 2 }
+
+-- System Breakers
+
+xPDUSystemBreakerTableSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of system breaker entries."
+ ::= { xPDUSystemBreakers 1 }
+
+xPDUSystemBreakerTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF XPDUSystemBreakerTableEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A list of system breaker entries.
+ The number of entries is contained in the
+ xPDUSystemBreakerTableSize OID."
+ ::= { xPDUSystemBreakers 2 }
+
+ xPDUSystemBreakerTableEntry OBJECT-TYPE
+ SYNTAX XPDUSystemBreakerTableEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "An entry containing information applicable to a
+ particular system breaker."
+ INDEX { xPDUSystemBreakerTableIndex }
+ ::= { xPDUSystemBreakerTable 1 }
+
+ XPDUSystemBreakerTableEntry ::= SEQUENCE {
+ xPDUSystemBreakerTableIndex INTEGER,
+ xPDUSystemBreakerDescription DisplayString,
+ xPDUSystemBreakerPosition INTEGER
+ }
+
+ xPDUSystemBreakerTableIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Index of system breaker entries in the table."
+ ::= { xPDUSystemBreakerTableEntry 1 }
+
+xPDUSystemBreakerDescription OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..79))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A brief description of the system breakers."
+ ::= { xPDUSystemBreakerTableEntry 2 }
+
+ xPDUSystemBreakerPosition OBJECT-TYPE
+ SYNTAX INTEGER {
+ open (1),
+ closed (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates whether this breaker is open(1) or closed(2)."
+ ::= { xPDUSystemBreakerTableEntry 3 }
+
+-- Branch Breakers (Breaker Panel)
+
+xPDUNumOfBranchBreakers OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of branch breakers in the Panel."
+ ::= { xPDUBranchBreakers 1 }
+
+-- Branch Breakers Table
+
+xPDUBranchBreakerTableSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of branch breaker entries."
+ ::= { xPDUBranchBreakers 2 }
+
+xPDUBranchBreakerTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF XPDUBranchBreakerEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A list of branch breaker table entries. The
+ number of entries is given by the value of xPDUBranchBreakerTableSize
+ The number of entries is contained in the
+ xPDUBranchBreakerTableSize OID."
+ ::= { xPDUBranchBreakers 3 }
+
+ xPDUBranchBreakerEntry OBJECT-TYPE
+ SYNTAX XPDUBranchBreakerEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "An entry containing information applicable to a
+ particular branch breaker."
+ INDEX { xPDUBranchBreakerTableIndex }
+ ::= { xPDUBranchBreakerTable 1 }
+
+ XPDUBranchBreakerEntry ::= SEQUENCE {
+ xPDUBranchBreakerTableIndex INTEGER,
+ xPDUBranchBreakerRating INTEGER,
+ xPDUBranchBreakerRDPFeed INTEGER,
+ xPDUBranchBreakerTieIndicator INTEGER,
+ xPDUBranchBreakerCurrent INTEGER,
+ xPDUBranchBreakerOverCurrentThreshold INTEGER,
+ xPDUBranchBreakerUnderCurrentThreshold INTEGER
+ }
+
+ xPDUBranchBreakerTableIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Index of branch breaker entries in the table."
+ ::= { xPDUBranchBreakerEntry 1 }
+
+ xPDUBranchBreakerRating OBJECT-TYPE
+ SYNTAX INTEGER (0..100)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates current rating of this breaker.
+ 0=Breaker is not present.
+ 1=Earth leakage connection.
+ 2=Neutral connection.
+ A value greater than 2 indicates breaker current rating in Amps."
+ ::= { xPDUBranchBreakerEntry 2 }
+
+ xPDUBranchBreakerRDPFeed OBJECT-TYPE
+ SYNTAX INTEGER {
+ remoteDistribution (1),
+ noRemoteDistribution (2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates that a breaker position is feeding a remote
+ distribution panel."
+ ::= { xPDUBranchBreakerEntry 3 }
+
+ xPDUBranchBreakerTieIndicator OBJECT-TYPE
+ SYNTAX INTEGER {
+ breakerTied (1),
+ breakerUntied (2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates whether or not the breaker pole is physically
+ connected to the breaker immediately below."
+ ::= { xPDUBranchBreakerEntry 4 }
+
+ xPDUBranchBreakerCurrent OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the branch current in tenths of Amps or -1 when not available."
+ ::= { xPDUBranchBreakerEntry 5 }
+
+ xPDUBranchBreakerOverCurrentThreshold OBJECT-TYPE
+ SYNTAX INTEGER (0..100)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Threshold above which a branch circuit over current
+ condition will be generated.
+ Specified as a percent of the branch breaker rating."
+ ::= { xPDUBranchBreakerEntry 6 }
+
+ xPDUBranchBreakerUnderCurrentThreshold OBJECT-TYPE
+ SYNTAX INTEGER (0..100)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Threshold below which a branch circuit under current
+ condition will be generated.
+ Specified as a percent of the branch breaker rating."
+ ::= { xPDUBranchBreakerEntry 7 }
+
+-- the xPDUInputContacts group
+
+xPDUInputContactNumContacts OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of contacts supported by the PDU."
+ ::= { xPDUInputContacts 1 }
+
+xPDUInputContactTableSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of input contact entries."
+ ::= { xPDUInputContacts 2 }
+
+xPDUInputContactTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF XPDUInputContactEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A list of contacts supported by the PDU.
+ The number of entries is contained in the
+ xPDUInputContactTableSize OID."
+ ::= { xPDUInputContacts 3 }
+
+xPDUInputContactEntry OBJECT-TYPE
+ SYNTAX XPDUInputContactEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A contact entry containing information for a given contact."
+ INDEX { xPDUInputContactNumber }
+ ::= { xPDUInputContactTable 1 }
+
+XPDUInputContactEntry ::=
+ SEQUENCE {
+ xPDUInputContactNumber INTEGER,
+ xPDUInputContactName DisplayString,
+ xPDUInputContactNormalState INTEGER,
+ xPDUInputContactCurrentState INTEGER
+ }
+
+xPDUInputContactNumber OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "An index identifying the contact on the PDU."
+ ::= { xPDUInputContactEntry 1 }
+
+xPDUInputContactName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The description of the purpose/use of the contact."
+ ::= { xPDUInputContactEntry 2 }
+
+xPDUInputContactNormalState OBJECT-TYPE
+ SYNTAX INTEGER {
+ open (1),
+ closed (2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The normal operating position of the contact."
+ ::= { xPDUInputContactEntry 3 }
+
+xPDUInputContactCurrentState OBJECT-TYPE
+ SYNTAX INTEGER {
+ open (1),
+ closed (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This value indicates the current state of the contact."
+ ::= { xPDUInputContactEntry 4 }
+
+-- the xPDUOutputRelays group
+
+xPDUOutputRelaysNumRelays OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of output relays supported by the PDU."
+ ::= { xPDUOutputRelays 1 }
+
+xPDUOutputRelaysTableSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of output relay entries."
+ ::= { xPDUOutputRelays 2 }
+
+xPDUOutputRelayTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF XPDUOutputRelayEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A list of output relays supported by the PDU.
+ The number of entries is contained in the
+ xPDUOutputRelayTableSize OID."
+ ::= { xPDUOutputRelays 3 }
+
+xPDUOutputRelayEntry OBJECT-TYPE
+ SYNTAX XPDUOutputRelayEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A output relay entry containing information for a given contact."
+ INDEX { xPDUOutputRelayNumber }
+ ::= { xPDUOutputRelayTable 1 }
+
+XPDUOutputRelayEntry ::=
+ SEQUENCE {
+ xPDUOutputRelayNumber INTEGER,
+ xPDUOutputRelayName DisplayString,
+ xPDUOutputRelayNormalState INTEGER,
+ xPDUOutputRelayCurrentState INTEGER
+ }
+
+xPDUOutputRelayNumber OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "An index identifying the output relay on the PDU."
+ ::= { xPDUOutputRelayEntry 1 }
+
+xPDUOutputRelayName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The description of the purpose/use of the output relay."
+ ::= { xPDUOutputRelayEntry 2 }
+
+xPDUOutputRelayNormalState OBJECT-TYPE
+ SYNTAX INTEGER {
+ open (1),
+ closed (2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The normal operating position of the output relay."
+ ::= { xPDUOutputRelayEntry 3 }
+
+xPDUOutputRelayCurrentState OBJECT-TYPE
+ SYNTAX INTEGER {
+ open (1),
+ closed (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This value indicates the current state of the output relay."
+ ::= { xPDUOutputRelayEntry 4 }
+
+-- the xPDUMiscGroup
+
+xPDUEPOMode OBJECT-TYPE
+ SYNTAX INTEGER {
+ armed (1),
+ disarmed (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates whether the EPO System is armed(1) or disarmed(2)."
+ ::= { xPDUMiscGroup 1 }
+
+xPDUTransformTempStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ normal (1),
+ overtemp (2),
+ noTransformerPresent (3)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates if the PDU's isolation transformer is over temperature."
+ ::= { xPDUMiscGroup 2 }
+
+xPDUCoolingFanStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ normal (1),
+ failed (2),
+ noCoolingFansPresent (3)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates if one or more of the PDU's cooling fans have failed."
+ ::= { xPDUMiscGroup 3 }
+
+-- The xATSIdent group
+
+xATSIdentProductName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The name of the transfer switch unit."
+ ::= { xATSIdent 1 }
+
+xATSIdentHardwareRev OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The hardware revision of the transfer switch.
+ This value is set at the factory."
+ ::= { xATSIdent 2 }
+
+xATSIdentFirmwareAppRev OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "An ID string identifying the application firmware revision of the transfer switch."
+ ::= { xATSIdent 3 }
+
+xATSIdentFirmwareAppOSRev OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "An ID string identifying the application operating system firmware revision of the transfer switch."
+ ::= { xATSIdent 4 }
+
+xATSIdentFirmwareControllerRev OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "An ID string identifying the transfer switch controller firmware revision."
+ ::= { xATSIdent 5 }
+
+xATSIdentDateOfManufacture OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The date when the transfer switch was manufactured in mm/dd/yyyy format.
+ This value is set at the factory."
+ ::= { xATSIdent 6 }
+
+xATSIdentModelNumber OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A character string identifying the model number of the transfer switch.
+ This value is set at the factory."
+ ::= { xATSIdent 7 }
+
+xATSIdentSerialNumber OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A character string identifying the serial number of the transfer switch.
+ This value is set at the factory."
+ ::= { xATSIdent 8 }
+
+-- The xATSDevice group
+
+xATSDeviceServiceType OBJECT-TYPE
+ SYNTAX INTEGER {
+ threeWire (1),
+ fourWire (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The type of utility input to the transfer switch.
+ Either 3 wires (delta), or 4 wires (wye)."
+ ::= { xATSDevice 1 }
+
+xATSDeviceNominalVoltage OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The nominal line-to-neutral system voltage.
+ Measured in Volts, line-to-line for a 3-wire service or
+ line-to-neutral for a 4-wire service. -1 if not available."
+ ::= { xATSDevice 2 }
+
+xATSDeviceNominalFrequency OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The nominal system frequency. Measured in tenths of Hertz.
+ -1 if not available."
+ ::= { xATSDevice 3 }
+
+xATSDeviceTransferSwitchRating OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The rating of the transfer switch.
+ Measured in Amps."
+ ::= { xATSDevice 4 }
+
+xATSDeviceDCBackUpPresent OBJECT-TYPE
+ SYNTAX INTEGER{
+ yes (1),
+ no (2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates if a DC backup is present or not."
+ ::= { xATSDevice 5 }
+
+-- The xATS Switch Status group
+
+xATSSwitchStatusSelectedSource OBJECT-TYPE
+ SYNTAX INTEGER{
+ none (1),
+ source1 (2),
+ source2 (3),
+ fault (4),
+ unknown (5)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The source which is currently selected, i.e. supplying power to the load."
+ ::= { xATSSwitchStatus 1 }
+
+xATSSwitchStatusOperationalMode OBJECT-TYPE
+ SYNTAX INTEGER{
+ automatic (1),
+ notInAutoAbnormal (2),
+ notInAuto (3),
+ unknown (4)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The current operating mode of the transfer switch. When the ATS is in
+ automatic mode, generator starting and ATS transferring is all done automatically
+ as needed based on the state of source 1. Automatic operation is halted when the
+ ATS is in either of the notInAuto modes.
+ A mode of notInAuto indicates that the automatic operation switch is in the
+ disabled position, as indicated by the xATSSwitchStatusAutomaticOperationSwitch OID.
+ The notInAutoAbnormal condition indicates that an abnormal
+ condition has caused the transfer switch to halt automatic operation.
+ In this case, traps can indicate the exact problem. In the case of
+ notInAutoAbnormal, refer to the operation manual for details
+ on how debug the condition and restore automatic operation."
+ ::= { xATSSwitchStatus 2 }
+
+xATSSwitchStatusAutomaticOperationSwitch OBJECT-TYPE
+ SYNTAX INTEGER{
+ disabled (1),
+ enabled (2),
+ unknown (3)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The position of the automatic operation switch on the front of the transfer switch."
+ ::= { xATSSwitchStatus 3 }
+
+xATSSwitchStatusEngineStartSignal OBJECT-TYPE
+ SYNTAX INTEGER{
+ run (1),
+ stop (2),
+ unknown (3)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The position of the Start/Stop contact which signals the generator
+ engine to start/run. When the ATS is in automatic mode,
+ generator starting/stopping is under ATS control."
+ ::= { xATSSwitchStatus 4 }
+
+-- The xATS Switch Setting group
+
+xATSSwitchSettingsLowVoltageTransferPoint OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The lowest acceptable voltage condition at source 1.
+ When any phase of source 1 is lower than this voltage,
+ source quality is considered bad and the generator run signal
+ is asserted to begin generator operation.
+ Specified in volts, line-to-line for a 3-wire service or
+ line-to-neutral for a 4-wire service.
+ -1 if not available."
+ ::= { xATSSwitchSettings 1 }
+
+xATSSwitchSettingsHighVoltageTransferPoint OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The highest acceptable voltage condition at source 1.
+ When any phase of source 1 is greater than this voltage,
+ source quality is considered bad and the generator run signal
+ is asserted to begin generator operation.
+ Specified in volts, line-to-line for a 3-wire service or
+ line-to-neutral for a 4-wire service.
+ -1 if not available."
+ ::= { xATSSwitchSettings 2 }
+
+xATSSwitchSettingsMaxFrequencyDeviation OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The maximum acceptable frequency deviation condition from nominal at source 1.
+ When source 1 frequency is outside the specified range,
+ source quality is considered bad and the generator run signal
+ is asserted to begin generator operation.
+ Specified in tenths of Hertz above or below nominal.
+ A value of zero indicates that frequency is ignored when
+ determining source quality.
+ -1 if not available."
+ ::= { xATSSwitchSettings 3 }
+
+xATSSwitchSettingsMinPhaseBalance OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The minimum required phase balance at source 1.
+ When the percentage difference between the minimum and maximum
+ phase voltage measurements at source 1 is greater than this value,
+ source quality is considered bad and the generator run signal
+ is asserted to begin generator operation.
+ Specified as a percentage. A value of zero indicates that phase balance
+ is ignored when determining source quality.
+ -1 if not available."
+ ::= { xATSSwitchSettings 4 }
+
+xATSSwitchSettingsNominalRotation OBJECT-TYPE
+ SYNTAX INTEGER{
+ abc (1),
+ cba (2),
+ any (3),
+ unknown (4)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The nominal phase rotation (or phase sequence) required by the load.
+ For certain types of equipment, such as rotating machinery, phase rotation
+ is critical for proper operation as it determines the direction which motors
+ will rotate (clockwise or counterclockwise).
+ Source quality will be seen as bad if the rotation measured at that
+ ATS input does not match this setting.
+ If this setting is set to any, phase rotation is ignored."
+ ::= { xATSSwitchSettings 5 }
+
+xATSSwitchSettingsAllowClosedTransfer OBJECT-TYPE
+ SYNTAX INTEGER{
+ yes (1),
+ no (2),
+ unknown (3)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "This setting enables seemless (closed) transfers between sources.
+ When possible, both source 1 and source 2 are closed to the output
+ for a brief time. If closed transfer is not possible within the amount
+ of time specified by the xATSSwitchSettingsMaxSyncTime OID,
+ an open transfer will be executed."
+ ::= { xATSSwitchSettings 6 }
+
+xATSSwitchSettingsMaxSyncTime OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "When attempting/seeking to perform a closed transfer, this setting defines
+ the maximum time allowed before the transfer switch will give up and perform
+ an open transfer. Specified in seconds.
+ -1 if not available."
+ ::= { xATSSwitchSettings 7 }
+
+xATSSwitchSettingsNeutralTransferTime OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "This setting defines how long both source 1 and source 2 will be
+ disconnected from the output, during an open transfer.
+ Specified in seconds.
+ -1 if not available."
+ ::= { xATSSwitchSettings 8 }
+
+xATSSwitchSettingsClearLatchedAlarms OBJECT-TYPE
+ SYNTAX INTEGER{
+ yes (1),
+ no (2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Clears any latched alarm conditions."
+ ::= { xATSSwitchSettings 9 }
+
+xATSSwitchSettingsSetToFactoryDefaults OBJECT-TYPE
+ SYNTAX INTEGER{
+ yes (1),
+ no (2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Sets all transfer switch settings to factory default values."
+ ::= { xATSSwitchSettings 10 }
+
+
+-- The xATSSwitchTimers group
+
+ xATSSwitchTimersTableSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of transfer switch timer entries."
+ ::= { xATSSwitchTimers 1 }
+
+ xATSSwitchTimersTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF XATSSwitchTimersEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A list of timers supported by ATS.
+ The number of entries is contained in the xATSSwitchTimersTableSize OID."
+ ::= { xATSSwitchTimers 2 }
+
+ xATSSwitchTimersEntry OBJECT-TYPE
+ SYNTAX XATSSwitchTimersEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "An entry containing information about an individual ATS timer."
+ INDEX { xATSSwitchTimersIndex }
+ ::= { xATSSwitchTimersTable 1 }
+
+ XATSSwitchTimersEntry ::=
+ SEQUENCE {
+ xATSSwitchTimersIndex INTEGER,
+ xATSSwitchTimersName DisplayString,
+ xATSSwitchTimersAbort INTEGER,
+ xATSSwitchTimersStatus INTEGER,
+ xATSSwitchTimersRemainingTime INTEGER,
+ xATSSwitchTimersDelaySetting INTEGER
+ }
+
+xATSSwitchTimersIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Index of timer entries in the table."
+ ::= { xATSSwitchTimersEntry 1 }
+
+xATSSwitchTimersName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Name of the individual timer.Refer to ATS operation manual,
+ or on-line help, for detailed descriptions of ATS timers."
+ ::= { xATSSwitchTimersEntry 2 }
+
+xATSSwitchTimersAbort OBJECT-TYPE
+ SYNTAX INTEGER{
+ yes (1),
+ no (2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "This aborts the individual timer."
+ ::= { xATSSwitchTimersEntry 3 }
+
+xATSSwitchTimersStatus OBJECT-TYPE
+ SYNTAX INTEGER{
+ inactive (1),
+ active (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The status of the individual timer. Designates whether this timer
+ entry is currently running or inactive."
+ ::= { xATSSwitchTimersEntry 4 }
+
+xATSSwitchTimersRemainingTime OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The time remaining for this timer entry.
+ Specified in seconds."
+ ::= { xATSSwitchTimersEntry 5 }
+
+xATSSwitchTimersDelaySetting OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The delay settings associated with this timer entry.
+ When this timer entry is active, the timer value must exceed this setting
+ before the ATS behavior associated with this timer is executed.
+ Refer to ATS operation manual, or on-line help, for detailed
+ descriptions of ATS timers."
+ ::= { xATSSwitchTimersEntry 6 }
+
+-- The xATSSwitchBlockMap group
+
+ xATSSwitchBlockMapTableSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of blocking map entries, or how many ATS actions can be blocked."
+ ::= { xATSSwitchBlockMap 1 }
+
+ xATSSwitchBlockMapTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF XATSSwitchBlockMapEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A list of blocking maps supported by the ATS.
+ The number of entries is contained in the xATSSwitchBlockMapTableSize OID."
+ ::= { xATSSwitchBlockMap 2 }
+
+ xATSSwitchBlockMapEntry OBJECT-TYPE
+ SYNTAX XATSSwitchBlockMapEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "An entry containing information about a specific ATS blocking map."
+ INDEX { xATSSwitchBlockMapIndex }
+ ::= { xATSSwitchBlockMapTable 1 }
+
+ XATSSwitchBlockMapEntry ::=
+ SEQUENCE {
+ xATSSwitchBlockMapIndex INTEGER,
+ xATSSwitchBlockMapName DisplayString,
+ xATSSwitchBlockMapStatus INTEGER,
+ xATSSwitchBlockMapSetting INTEGER
+ }
+
+ xATSSwitchBlockMapIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Index of blocking map entries in the table."
+ ::= { xATSSwitchBlockMapEntry 1 }
+
+ xATSSwitchBlockMapName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A string describing the ATS action to be blocked."
+ ::= { xATSSwitchBlockMapEntry 2 }
+
+ xATSSwitchBlockMapStatus OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Represents the status of this blocking map entry, in bit-mapped format.
+ A non-zero value indicates that this entry's ATS action is currently being blocked.
+ The bit(s) set indicate which input(s) are causing the blocking (bit0, bit1, etc).
+
+ bit 0 - Contact 1
+ bit 1 - Contact 2
+ bit 2 - Contact 3
+ bit 3 - Contact 4."
+ ::= { xATSSwitchBlockMapEntry 3 }
+
+ xATSSwitchBlockMapSetting OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "This setting designates the inputs that block the ATS action
+ The mapping is specified as a bit-field, where each bit set indicates
+ the input that blocks the ATS action associated with the entry.
+
+ bit 0 - Contact 1
+ bit 1 - Contact 2
+ bit 2 - Contact 3
+ bit 3 - Contact 4."
+ ::= { xATSSwitchBlockMapEntry 4 }
+
+-- The xATSSwitchStatistics group
+
+ xATSSwitchStatisticsTableSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of transfer switch statistics entries."
+ ::= { xATSSwitchStatistics 1 }
+
+ xATSSwitchStatisticsTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF XATSSwitchStatisticsEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A list of statistics supported by ATS.
+ The number of entries is contained in the xATSSwitchStatisticsTableSize OID."
+ ::= { xATSSwitchStatistics 2 }
+
+ xATSSwitchStatisticsEntry OBJECT-TYPE
+ SYNTAX XATSSwitchStatisticsEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "An entry containing information about an individual ATS statistic."
+ INDEX { xATSSwitchStatisticsIndex }
+ ::= { xATSSwitchStatisticsTable 1 }
+
+ XATSSwitchStatisticsEntry ::=
+ SEQUENCE {
+ xATSSwitchStatisticsIndex INTEGER,
+ xATSSwitchStatisticsName DisplayString,
+ xATSSwitchStatisticsValue DisplayString,
+ xATSSwitchStatisticsReset INTEGER
+ }
+
+ xATSSwitchStatisticsIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Index of ATS statistics entries in the table."
+ ::= { xATSSwitchStatisticsEntry 1 }
+
+ xATSSwitchStatisticsName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This is the name of the ATS statistic associated with this entry."
+ ::= { xATSSwitchStatisticsEntry 2 }
+
+ xATSSwitchStatisticsValue OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This is the value of the ATS statistic associated with this entry."
+ ::= { xATSSwitchStatisticsEntry 3 }
+
+ xATSSwitchStatisticsReset OBJECT-TYPE
+ SYNTAX INTEGER{
+ yes (1),
+ no (2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "This will reset the individual ATS statistic associated with this entry."
+ ::= { xATSSwitchStatisticsEntry 4 }
+
+-- The xATS Source 1 group
+
+xATSSource1Name OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "String used to identify source 1."
+ ::= { xATSSource1 1 }
+
+xATSSource1Position OBJECT-TYPE
+ SYNTAX INTEGER{
+ open (1),
+ closed (2),
+ tripped (3),
+ unknown (4)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The current position of the switch at source 1."
+ ::= { xATSSource1 2 }
+
+xATSSource1Frequency OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The frequency at source 1 in tenths of Hertz.
+ -1 if unavailable."
+ ::= { xATSSource1 3 }
+
+xATSSource1Quality OBJECT-TYPE
+ SYNTAX INTEGER{
+ sourceGood (1),
+ lowVoltage (2),
+ highVoltage (3),
+ phaseImbalance (4),
+ freqOutOfRange (5),
+ badRotation (6),
+ unknown (7)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The current line quality of source 1."
+ ::= { xATSSource1 4 }
+
+xATSSource1Rotation OBJECT-TYPE
+ SYNTAX INTEGER{
+ abc (1),
+ cba (2),
+ unknown (3)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The phase rotation measured at the source 1 input of the ATS.
+ The sequence is a reference to the order in which the three phases
+ pass the zero-crossing boundary in time."
+ ::= { xATSSource1 5 }
+
+xATSSource1TableSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of input voltage entries at the source 1 input of the ATS."
+ ::= { xATSSource1 6 }
+
+ xATSSource1Table OBJECT-TYPE
+ SYNTAX SEQUENCE OF XATSSource1PhaseEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A list of voltage table entries for source 1. The number of
+ entries are the phase entries. The number of entries is contained in the
+ xATSSource1TableSize OID."
+ ::= { xATSSource1 7 }
+
+ xATSSource1PhaseEntry OBJECT-TYPE
+ SYNTAX XATSSource1PhaseEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "An entry containing information applicable to a
+ particular input voltage phase at the source 1 input of the ATS."
+ INDEX { xATSSource1Index }
+ ::= { xATSSource1Table 1 }
+
+ XATSSource1PhaseEntry ::= SEQUENCE {
+ xATSSource1Index INTEGER,
+ xATSSource1VoltageLtoL INTEGER,
+ xATSSource1VoltageLtoN INTEGER
+ }
+
+ xATSSource1Index OBJECT-TYPE
+ SYNTAX INTEGER{
+ phase1(1),
+ phase2(2),
+ phase3(3)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Description of each phase utilized at source 1."
+ ::= { xATSSource1PhaseEntry 1 }
+
+ xATSSource1VoltageLtoL OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Source 1 line-to-line input voltage.
+ Measured in tenths of Volts."
+ ::= { xATSSource1PhaseEntry 2 }
+
+ xATSSource1VoltageLtoN OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Source 1 line-to-neutral input voltage.
+ Measured in tenths of Volts. -1 for a 3-wire service type."
+ ::= { xATSSource1PhaseEntry 3 }
+
+-- The xATS Source 2 group
+
+xATSSource2Name OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "String used to identify source 2."
+ ::= { xATSSource2 1 }
+
+xATSSource2Position OBJECT-TYPE
+ SYNTAX INTEGER{
+ open (1),
+ closed (2),
+ tripped (3),
+ unknown (4)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The current position of the switch at source 2."
+ ::= { xATSSource2 2 }
+
+xATSSource2Frequency OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The frequency at source 2 in tenths of Hertz.
+ -1 if not available."
+ ::= { xATSSource2 3 }
+
+xATSSource2Quality OBJECT-TYPE
+ SYNTAX INTEGER{
+ sourceGood (1),
+ lowVoltage (2),
+ highVoltage (3),
+ phaseImbalance (4),
+ freqOutOfRange (5),
+ badRotation (6),
+ unknown (7)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The current line quality of source 2."
+ ::= { xATSSource2 4 }
+
+xATSSource2Rotation OBJECT-TYPE
+ SYNTAX INTEGER{
+ abc (1),
+ cba (2),
+ unknown (3)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The phase rotation measured at the source 2 input of the ATS.
+ -1 if not available."
+ ::= { xATSSource2 5 }
+
+xATSSource2TableSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of input voltage entries at the source 2 input of the ATS."
+ ::= { xATSSource2 6 }
+
+ xATSSource2Table OBJECT-TYPE
+ SYNTAX SEQUENCE OF XATSSource2PhaseEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A list of voltage table entries for the source 2. The number of
+ entries are the phase entries. The number of entries is contained in the
+ xATSSource2TableSize OID."
+ ::= { xATSSource2 7 }
+
+ xATSSource2PhaseEntry OBJECT-TYPE
+ SYNTAX XATSSource2PhaseEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "An entry containing information applicable to a
+ particular input voltage phase at the source 2 input of the ATS."
+ INDEX { xATSSource2Index }
+ ::= { xATSSource2Table 1 }
+
+ XATSSource2PhaseEntry ::= SEQUENCE {
+ xATSSource2Index INTEGER,
+ xATSSource2VoltageLtoL INTEGER,
+ xATSSource2VoltageLtoN INTEGER
+ }
+
+ xATSSource2Index OBJECT-TYPE
+ SYNTAX INTEGER{
+ phase1(1),
+ phase2(2),
+ phase3(3)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Description of each phase utilized at the source 2."
+ ::= { xATSSource2PhaseEntry 1 }
+
+ xATSSource2VoltageLtoL OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Source 2 line-to-line input voltage.
+ Measured in tenths of Volts."
+ ::= { xATSSource2PhaseEntry 2 }
+
+ xATSSource2VoltageLtoN OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Source 2 line-to-neutral input voltage.
+ Measured in tenths of Volts. -1 for a 3-wire service type."
+ ::= { xATSSource2PhaseEntry 3 }
+
+-- The xATSSystemOutput
+
+xATSSystemOutputFrequency OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The system output frequency in tenths of Hertz."
+ ::= { xATSSystemOutput 1 }
+
+xATSSystemOutputTotalPower OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Shows the total system output power in tenths of kW."
+ ::= { xATSSystemOutput 2 }
+
+xATSSystemOutputTotalApparentPower OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Shows the total system output power in tenths of kVA."
+ ::= { xATSSystemOutput 3 }
+
+xATSSystemOutputTotalPowerFactor OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the total power factor of the system output.
+ A value of 100 representing a unity power factor (1.00)
+ Specified in hundredths."
+ ::= { xATSSystemOutput 4 }
+
+xATSSystemOutputFrequencyTolerance OBJECT-TYPE
+ SYNTAX INTEGER{
+ freqToleranceOff (1),
+ freqTolerancePointTwo (2),
+ freqTolerancePointFive (3),
+ freqToleranceOne (4),
+ freqToleranceOnePointFive (5),
+ freqToleranceTwo (6),
+ freqToleranceThree (7),
+ freqToleranceFour (8),
+ freqToleranceFive (9),
+ freqToleranceNine (10)
+
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Shows the panel output frequency tolerance in +/- Hertz."
+ ::= { xATSSystemOutput 5 }
+
+xATSSystemOutputOverVoltThreshold OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Threshold above which an output over voltage condition will be generated.
+ Specified as tenths of percent deviation from nominal.
+ A value of zero indicates that the threshold is disabled."
+ ::= { xATSSystemOutput 6 }
+
+xATSSystemOutputUnderVoltThreshold OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Threshold below which an output under voltage condition will be generated.
+ Specified as tenths of percent deviation from nominal.
+ A value of zero indicates that the threshold is disabled."
+ ::= { xATSSystemOutput 7 }
+
+xATSSystemOutputOverCurrentThreshold OBJECT-TYPE
+ SYNTAX INTEGER (0..100)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Threshold above which an over current condition will be generated.
+ Specified as a percent of the transfer switch rating (xATSDeviceTransferSwitchRating OID).
+ A value of zero indicates that the threshold is disabled."
+ ::= { xATSSystemOutput 8 }
+
+xATSSystemOutputUnderCurrentThreshold OBJECT-TYPE
+ SYNTAX INTEGER (0..100)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Threshold below which an under current condition will be generated.
+ Specified as a percent of the transfer switch rating (xATSDeviceTransferSwitchRating OID).
+ A value of zero indicates that the threshold is disabled."
+ ::= { xATSSystemOutput 9 }
+
+xATSSystemOutputAlarmDelayThreshold OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Delay the generation of an output alarm.
+ Specified in seconds."
+ ::= { xATSSystemOutput 10 }
+
+xATSSystemOutputTableSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of system output phase entries."
+ ::= { xATSSystemOutput 11 }
+
+xATSSystemOutputTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF XATSSystemOutputPhaseEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A list of system output table entries.
+ The number of entries is contained in the xATSSystemOutputTableSize OID."
+ ::= { xATSSystemOutput 12 }
+
+ xATSSystemOutputPhaseEntry OBJECT-TYPE
+ SYNTAX XATSSystemOutputPhaseEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "An entry containing information applicable to a
+ particular system output phase."
+ INDEX { xATSSystemOutputPhaseIndex }
+ ::= { xATSSystemOutputTable 1 }
+
+ XATSSystemOutputPhaseEntry ::= SEQUENCE {
+ xATSSystemOutputPhaseIndex INTEGER,
+ xATSSystemOutputVoltageLtoL INTEGER,
+ xATSSystemOutputVoltageLtoN INTEGER,
+ xATSSystemOutputPhaseCurrent INTEGER,
+ xATSSystemOutputPower INTEGER,
+ xATSSystemOutputApparentPower INTEGER,
+ xATSSystemOutputPowerFactor INTEGER
+ }
+
+ xATSSystemOutputPhaseIndex OBJECT-TYPE
+ SYNTAX INTEGER{
+ phase1(1),
+ phase2(2),
+ phase3(3)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Description of each system output phase utilized in this device."
+ ::= { xATSSystemOutputPhaseEntry 1 }
+
+ xATSSystemOutputVoltageLtoL OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Line-to-line system output voltage, measured in tenths of Volts, available at the circuit panel.
+ -1 if not available."
+ ::= { xATSSystemOutputPhaseEntry 2 }
+
+ xATSSystemOutputVoltageLtoN OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Line-to-neutral system output voltage, measured in tenths of Volts, available at the circuit panel.
+ -1 for a 3-wire service type or if not available."
+ ::= { xATSSystemOutputPhaseEntry 3 }
+
+ xATSSystemOutputPhaseCurrent OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "System load current per phase. Measured in Amps.
+ -1 if not available."
+ ::= { xATSSystemOutputPhaseEntry 4 }
+
+ xATSSystemOutputPower OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "System output power per phase. Measured in tenths of kW."
+ ::= { xATSSystemOutputPhaseEntry 5 }
+
+ xATSSystemOutputApparentPower OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "system output power per phase. Measured in tenths of kVA."
+ ::= { xATSSystemOutputPhaseEntry 6 }
+
+ xATSSystemOutputPowerFactor OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "indicates the power factor of the system output per phase.
+ A value of 100 representing a unity power factor (1.00).
+ Measured in hundredths."
+ ::= { xATSSystemOutputPhaseEntry 7 }
+
+-- xATS TestingStatus group
+
+xATSTestingStatusSelectTestProcess OBJECT-TYPE
+ SYNTAX INTEGER {
+ engineStartTest (1),
+ systemLoadTest (2),
+ generatorHoldTest (3),
+ cancelTest (4)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Type of tests that can be selected when no test has been scheduled.
+ engineStartTest and systemLoadTest may be selected when no tests
+ are running. Tests that are selected may be cancelled manually."
+ ::= { xATSTestingStatus 1 }
+
+xATSTestingStatusTestStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ noTestInProcess (1),
+ testPending (2),
+ startingEngine (3),
+ engineWarmingUp (4),
+ awaitingTransferToS2 (5),
+ testingWithLoad (6),
+ awaitingRetransferToS1 (7),
+ testingWithoutLoad (8),
+ stoppingEngine (9),
+ holdingOnGenerator (10)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The present system test status/state."
+ ::= { xATSTestingStatus 2 }
+
+xATSTestingStatusProfileWarmupTime OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The amount of time that the generator will warm up during a test.
+ This is portion of the test when the xATSTestingStatusTestStatus
+ OID returns the value engineWarmingUp.
+ Specified in seconds."
+ ::= { xATSTestingStatus 3 }
+
+xATSTestingStatusProfileLoadedTime OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The amount of time that ATS will apply the system load to the generator
+ during a system load test.
+ This is portion of the test when the xATSTestingStatusTestStatus
+ OID returns the value testingWithLoad.
+ Specified in minutes."
+ ::= { xATSTestingStatus 4 }
+
+xATSTestingStatusProfileUnloadedTime OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The amount of time that the generator will run following the warm up
+ portion of a start test, or the loaded portion of a load test.
+ This is portion of the test when the xATSTestingStatusTestStatus
+ OID returns the value testingWithoutLoad.
+ Specified in seconds."
+ ::= { xATSTestingStatus 5 }
+
+-- xATS TestingResults group
+
+xATSTestingResultsLastDateOfTest OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Date of the last test that was performed, either scheduled or manual.
+ Test results are available in the xATSTestingResultsLastResult OID.
+ Specified in the dd/mm/yyyy format, or 'none' if not available."
+ ::= { xATSTestingResults 1 }
+
+xATSTestingResultsLastResult OBJECT-TYPE
+ SYNTAX INTEGER {
+ startTestPassed (1),
+ loadTestPassed (2),
+ startSignalFailure (3),
+ failedGenNotInAuto (4),
+ failedGenEmerStop (5),
+ failedGenShutdown (6),
+ failedGenDidNotStart (7),
+ failedS2NeverGood (8),
+ genFailedDuringWarmup (9),
+ failureOnXferToS1 (10),
+ genFailedLoaded (11),
+ failureOnRexferToS2 (12),
+ genFailedToStop (13),
+ failedAtsInternalFault (14),
+ failedAtsNotInAuto (15),
+ cancelledManualTest (16),
+ cancelledScheduledTest (17)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The result of the last ATS/generator system test."
+ ::= { xATSTestingResults 2 }
+
+xATSTestingResultsTestLastTestTime OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Time of day at which the last test was performed, either scheduled or manual.
+ Test results are available in the xATSTestingResultsLastResult OID.
+ Specified in the hh:mm:ss format, or 'none' if not available."
+ ::= { xATSTestingResults 3 }
+
+xATSTestingResultsLastCrankDuration OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The time spent cranking the generator before it started during the last test.
+ Specified in seconds, or -1 if not available."
+ ::= { xATSTestingResults 4 }
+
+xATSTestingResultsLastWarmupDuration OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The time spent in the engineWarmingUp state during the last system test.
+ Specified in seconds, or -1 if not available."
+ ::= { xATSTestingResults 5 }
+
+xATSTestingResultsLastLoadedDuration OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The time spent in the testingWithLoad state during the last system test.
+ Specified in seconds, or -1 if not available."
+ ::= { xATSTestingResults 6 }
+
+xATSTestingResultsLastUnloadedDuration OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The time spent in the testingWithoutLoad state during the last system test.
+ Specified in seconds, or -1 if not available."
+ ::= { xATSTestingResults 7 }
+
+-- xATS TestingSchedule group
+
+xATSTestingScheduleFrequency OBJECT-TYPE
+ SYNTAX INTEGER {
+ never (1),
+ daily (2),
+ weekly (3),
+ monthly (4)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The frequency of running scheduled tests."
+ ::= { xATSTestingSchedule 1 }
+
+xATSTestingScheduleTestDay OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The desired day for the scheduled test. This object applies only
+ when the xATSTestingScheduleFrequency OID is set to weekly or monthly.
+ For weekly test frequency, the string is the day the test will be run.
+ For monthly test frequency, the string indicates the day,
+ and the instance within the month.
+ For example, for monthly frequency: 2nd sunday, 3rd monday, 4th tuesday,
+ for weekly frequency: sunday, monday, tuesday."
+ ::= { xATSTestingSchedule 2 }
+
+xATSTestingScheduleTestTime OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The time of day that the scheduled test will occur.
+ Specified in the format hh:mm."
+ ::= { xATSTestingSchedule 3 }
+
+xATSTestingScheduleTestWithLoadInterval OBJECT-TYPE
+ SYNTAX INTEGER {
+ applyLoadEveryTest (1),
+ neverApplyLoad (2),
+ applyLoadMonthly (3),
+ applyLoadMonthlyDetailed (4)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "This setting specifies which system tests should include applying the
+ load to the generator. The applyLoadMonthlyDetailed entry
+ in the list will apply load once, for each month represented in the
+ xATSTestingScheduleTestWithLoadSelectMonth OID."
+ ::= { xATSTestingSchedule 4 }
+
+xATSTestingScheduleTestWithLoadSelectMonth OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The detailed selection for testing with load on a month-by-month basis.
+ This object is applicable when the xATSTestingScheduleTestWithLoadInterval
+ is set to applyLoadMonthlyDetailed. Otherwise this selection will be ignored.
+ Format for this string is a comma-separated entry of months.
+ For example: Jan,Mar,Dec.
+ The string will return 'No Months Scheduled' if no months have been selected."
+ ::= { xATSTestingSchedule 5 }
+
+xATSTestingScheduleNextTestDate OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The date of the next scheduled test, in the format dd-mmm-yyyy."
+ ::= { xATSTestingSchedule 6 }
+
+-- xATSTestingSimulatePowerFail group
+
+xATSTestingSimulatePowerFailTest OBJECT-TYPE
+ SYNTAX INTEGER{
+ cancelSimulation (1),
+ fiveSecondsSimulation (2),
+ tenSecondsSimulation (3),
+ thirtySecondsSimulation (4),
+ oneMinuteSimulation (5),
+ threeMinutesSimulation (6),
+ fiveMinutesSimulation (7),
+ tenMinutesSimulation (8)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "This object executes a simulated power failure for the duration indicated.
+ Simulation can be aborted by selecting cancelSimulation."
+ ::= { xATSTestingSimulatePowerFail 1 }
+
+xATSTestingSimulatePowerFailTimeRemaining OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the time remaining in seconds, for a simulated power failure.
+ a value of zero indicates that simulated power failure is not active."
+ ::= { xATSTestingSimulatePowerFail 2 }
+
+-- The xATS Input Contact group
+
+xATSInputContactNumContacts OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of contacts supported by the ATS."
+ ::= { xATSInputContacts 1 }
+
+xATSInputContactTableSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of input contact entries."
+ ::= { xATSInputContacts 2 }
+
+xATSInputContactTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF XATSContactEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A list of contacts supported by the ATS.
+ The number of entries is contained in the
+ xATSInputContactTableSize OID."
+ ::= { xATSInputContacts 3 }
+
+ xATSInputContactEntry OBJECT-TYPE
+ SYNTAX XATSContactEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A contact entry containing information for a given contact."
+ INDEX { xATSInputContactNumber }
+ ::= { xATSInputContactTable 1 }
+
+ XATSContactEntry ::=
+ SEQUENCE {
+ xATSInputContactNumber INTEGER,
+ xATSInputContactName DisplayString,
+ xATSInputContactNormalState INTEGER,
+ xATSInputContactCurrentState INTEGER
+ }
+
+ xATSInputContactNumber OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "An index identifying the contact on the ATS."
+ ::= { xATSInputContactEntry 1 }
+
+ xATSInputContactName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The description of the purpose/use of the contact."
+ ::= { xATSInputContactEntry 2 }
+
+ xATSInputContactNormalState OBJECT-TYPE
+ SYNTAX INTEGER {
+ open (1),
+ closed (2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The normal operating position of the contact."
+ ::= { xATSInputContactEntry 3 }
+
+ xATSInputContactCurrentState OBJECT-TYPE
+ SYNTAX INTEGER {
+ open (1),
+ closed (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This value indicates the current state of the contact."
+ ::= { xATSInputContactEntry 4 }
+
+-- the xATS OutputRelays group
+
+ xATSOutputRelayNumRelays OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of output relays supported by the ATS."
+ ::= { xATSOutputRelays 1 }
+
+ xATSOutputRelayTableSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of output relay entries."
+ ::= { xATSOutputRelays 2 }
+
+ xATSOutputRelayTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF XATSOutputRelayEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A list of output relays supported by the ATS.
+ The number of entries is contained in the
+ xATSOutputRelayTableSize OID."
+ ::= { xATSOutputRelays 3 }
+
+ xATSOutputRelayEntry OBJECT-TYPE
+ SYNTAX XATSOutputRelayEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A output relay entry containing information for a given contact."
+ INDEX { xATSOutputRelayNumber }
+ ::= { xATSOutputRelayTable 1 }
+
+ XATSOutputRelayEntry ::=
+ SEQUENCE {
+ xATSOutputRelayNumber INTEGER,
+ xATSOutputRelayName DisplayString,
+ xATSOutputRelayNormalState INTEGER,
+ xATSOutputRelayCurrentState INTEGER
+ }
+
+ xATSOutputRelayNumber OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "An index identifying the output relay on the ATS."
+ ::= { xATSOutputRelayEntry 1 }
+
+ xATSOutputRelayName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The description of the purpose/use of the output relay."
+ ::= { xATSOutputRelayEntry 2 }
+
+ xATSOutputRelayNormalState OBJECT-TYPE
+ SYNTAX INTEGER {
+ open (1),
+ closed (2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The normal operating position of the output relay."
+ ::= { xATSOutputRelayEntry 3 }
+
+ xATSOutputRelayCurrentState OBJECT-TYPE
+ SYNTAX INTEGER {
+ open (1),
+ closed (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This value indicates the current state of the output relay."
+ ::= { xATSOutputRelayEntry 4 }
+
+-- The xATS Generator Ident group
+
+xATSGeneratorIdentModelNumber OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A character string identifying the model number of the generator.
+ This value is set at the factory."
+ ::= { xATSGeneratorIdent 1 }
+
+xATSGeneratorIdentSerialNumber OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A character string identifying the serial number of the generator.
+ This value is set at the factory."
+ ::= { xATSGeneratorIdent 2 }
+
+xATSGeneratorIdentDateofManufacture OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A character string identifying when the generator was manufactured in mm/dd/yyyy format.
+ This value is set at the factory."
+ ::= { xATSGeneratorIdent 3 }
+
+xATSGeneratorIdentVoltageConfiguration OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The voltage for which the generator's alternator is designed.
+ Specified in Volts line-to-line."
+ ::= { xATSGeneratorIdent 4 }
+
+xATSGeneratorIdentMaxPowerRating OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The max power rating of the generator. Specified in kW."
+ ::= { xATSGeneratorIdent 5 }
+
+xATSGeneratorIdentAlternatorFrequency OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The frequency for which the generator's alternator is designed.
+ Specified in Hertz."
+ ::= { xATSGeneratorIdent 6 }
+
+-- The xATS Generator Status group
+
+xATSGeneratorStatusGeneratorName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The name or label for the generator connected to the source 2 of the ATS."
+ ::= { xATSGeneratorStatus 1 }
+
+xATSGeneratorStatusOperational OBJECT-TYPE
+ SYNTAX INTEGER{
+ nocomm (1),
+ off (2),
+ ready (3),
+ starting (4),
+ idle (5),
+ running (6),
+ normalStop (7),
+ emergencyStop (8),
+ notInAuto (9),
+ shutdown (10),
+ unknown (11)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The operational status of the generator. unavailable when unrecognized status is received."
+ ::= { xATSGeneratorStatus 2 }
+
+xATSGeneratorStatusModeSwitchPosition OBJECT-TYPE
+ SYNTAX INTEGER{
+ off (1),
+ manual (2),
+ automatic (3),
+ unknown (4)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The position of the generator's auto-mode switch.
+ In automatic mode, the generator is started and stopped via the
+ remote start contact, which has state indicated in the
+ xATSGeneratorStatusRemoteStart OID.
+ In manual mode generator start/stop control is via local command only.
+ Off prevents the generator from running."
+ ::= { xATSGeneratorStatus 3 }
+
+xATSGeneratorStatusRemoteStart OBJECT-TYPE
+ SYNTAX INTEGER{
+ stop (1),
+ run (2),
+ unknown (3)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The status of the generator's remote start contact, which is
+ provided as an output from the transfer switch to start/stop the
+ generator when in automatic mode."
+ ::= { xATSGeneratorStatus 4 }
+
+-- The xATS Generator Advanced Status group
+
+xATSGeneratorAdvStatusBatteryVoltage OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The voltage of the generator's starting battery.
+ Measured in tenths of VDC, or -1 if not available."
+ ::= { xATSGeneratorAdvStatus 1 }
+
+xATSGeneratorAdvStatusOilPressure OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The generator's engine oil pressure.
+ Measured in tenths of Psi or kPa, based on the
+ value of the xATSGeneratorSettingsMetricUnit OID,
+ or -1 if not available."
+ ::= { xATSGeneratorAdvStatus 2 }
+
+xATSGeneratorAdvStatusCoolantTemperature OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Current coolant temperature in the generator.
+ Measured in degrees Celsius or Fahrenheit, based on the
+ value of the xATSGeneratorSettingsMetricUnit OID,
+ or -1 if not available."
+ ::= { xATSGeneratorAdvStatus 3 }
+
+xATSGeneratorAdvStatusEngineRPM OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Current engine speed of the generator.
+ Measured in RPM, or -1 if not available."
+ ::= { xATSGeneratorAdvStatus 4 }
+
+xATSGeneratorAdvStatusOilLevel OBJECT-TYPE
+ SYNTAX INTEGER{
+ ok (1),
+ low (2),
+ unknown (3)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates adequate oil level in the generator."
+ ::= { xATSGeneratorAdvStatus 5 }
+
+xATSGeneratorAdvStatusCoolantLevel OBJECT-TYPE
+ SYNTAX INTEGER{
+ ok (1),
+ low (2),
+ unknown (3)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates adequate coolant level in the generator."
+ ::= { xATSGeneratorAdvStatus 6 }
+
+-- The xATS Generator Output group
+
+xATSGeneratorOutputFrequency OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The output frequency of the generator.
+ Measured in tenths of Hertz, or -1 if not avaialble."
+ ::= { xATSGeneratorOutput 1 }
+
+xATSGeneratorOutputTotalPower OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The total output power of the generator.
+ Measured in tenths of tenths of kW, or -1 if not avaialble."
+ ::= { xATSGeneratorOutput 2 }
+
+xATSGeneratorOutputTotalApparentPower OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The total output power of the generator.
+ Measured in tenths of kVA, or -1 if not avaialble."
+ ::= { xATSGeneratorOutput 3 }
+
+xATSGeneratorOutputTotalPowerFactor OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the total load power factor of the generator.
+ A value of 100 representing a unity power factor (1.00),
+ or -1 when if not avaialble."
+ ::= { xATSGeneratorOutput 4 }
+
+xATSGeneratorOutputTableSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of generator output phase entries."
+ ::= { xATSGeneratorOutput 5 }
+
+ xATSGeneratorOutputTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF XATSGeneratorOutputPhaseEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A list of generator output table entries.
+ The number of entries is contained in the xATSGeneratorOutputTableSize OID."
+ ::= { xATSGeneratorOutput 6 }
+
+ xATSGeneratorOutputPhaseEntry OBJECT-TYPE
+ SYNTAX XATSGeneratorOutputPhaseEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "An entry containing information applicable to a
+ particular generator output phase."
+ INDEX { xATSGeneratorOutputPhaseIndex }
+ ::= { xATSGeneratorOutputTable 1 }
+
+ XATSGeneratorOutputPhaseEntry ::= SEQUENCE {
+ xATSGeneratorOutputPhaseIndex INTEGER,
+ xATSGeneratorOutputVoltageLtoL INTEGER,
+ xATSGeneratorOutputVoltageLtoN INTEGER,
+ xATSGeneratorOutputPhaseCurrent INTEGER,
+ xATSGeneratorOutputPower INTEGER,
+ xATSGeneratorOutputApparentPower INTEGER,
+ xATSGeneratorOutputPowerFactor INTEGER
+ }
+
+ xATSGeneratorOutputPhaseIndex OBJECT-TYPE
+ SYNTAX INTEGER{
+ phase1(1),
+ phase2(2),
+ phase3(3)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Description of each generator output phase utilized in this device."
+ ::= { xATSGeneratorOutputPhaseEntry 1 }
+
+ xATSGeneratorOutputVoltageLtoL OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Line-to-line generator output voltage.
+ Measured in Volts, or -1 if not available."
+ ::= { xATSGeneratorOutputPhaseEntry 2 }
+
+ xATSGeneratorOutputVoltageLtoN OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Line-to-neutral generator output voltage.
+ Measured in volts, or -1 if not avaialble."
+ ::= { xATSGeneratorOutputPhaseEntry 3 }
+
+ xATSGeneratorOutputPhaseCurrent OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Generator load current per phase.
+ Measured in Amps, or -1 if not avaialble."
+ ::= { xATSGeneratorOutputPhaseEntry 4 }
+
+ xATSGeneratorOutputPower OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Generator output power per phase.
+ Measured in tenths of kW, or -1 if not avaialble."
+ ::= { xATSGeneratorOutputPhaseEntry 5 }
+
+ xATSGeneratorOutputApparentPower OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Generator output power per phase.
+ Measured in tenths of kVA, or -1 if not available."
+ ::= { xATSGeneratorOutputPhaseEntry 6 }
+
+ xATSGeneratorOutputPowerFactor OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates the load power factor of the generator output per phase.
+ A value of 100 representing a unity power factor (1.00),
+ or -1 if not avaialble."
+ ::= { xATSGeneratorOutputPhaseEntry 7 }
+
+-- xATS Generator Settings group
+
+xATSGeneratorSettingsVoltageAdjust OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The voltage adjust of the generator.
+ Specified in volts line-to-line,
+ or -1 if not available."
+ ::= { xATSGeneratorSettings 1 }
+
+xATSGeneratorSettingsFrequencyAdjust OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The frequency adjust of the generator.
+ Specified in tenths of Hertz."
+ ::= { xATSGeneratorSettings 2 }
+
+xATSGeneratorSettingsStartDelay OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The delay, in seconds, after the remote run signal is activated
+ before the generator's engine will be cranked to start,
+ or -1 if not available."
+ ::= { xATSGeneratorSettings 3 }
+
+xATSGeneratorSettingsStopDelay OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The delay, in seconds, before the generator will stop
+ after the remote run signal is deactivated,
+ or -1 if not available."
+ ::= { xATSGeneratorSettings 4 }
+
+xATSGeneratorSettingsCrankCycleEnable OBJECT-TYPE
+ SYNTAX INTEGER{
+ disabled (1),
+ enabled (2),
+ unknown (3)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "When Crank Cycle is enabled, the engine will be cranked up to the time
+ specified by the xATSGeneratorSettingsCrankTime OID.
+ If the generator's engine does not start, there will be a pause as
+ specified by the xATSGeneratorSettingsCrankRestTime OID before the
+ engine will be cranked again. This cycle is repeated as specified by
+ the xATSGeneratorSettingsNumberCrank OID.
+ When crank cycle is disabled, the generator's engine will be
+ cranked continuously until it starts."
+ ::= { xATSGeneratorSettings 5 }
+
+xATSGeneratorSettingsCrankTime OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The duration of engine cranking, in seconds, when starting the generator.
+ Applicable when the xATSGeneratorSettingsCrankCycleEnable OID is enabled.
+ -1 if not available."
+ ::= { xATSGeneratorSettings 6 }
+
+xATSGeneratorSettingsCrankRestTime OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The pause duration, in seconds, following an unsuccessful attempt to start the generator.
+ Applicable when the xATSGeneratorSettingsCrankCycleEnable OID is enabled.
+ -1 if not available."
+ ::= { xATSGeneratorSettings 7 }
+
+xATSGeneratorSettingsNumberCrank OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of failed crank attempts before giving up on starting the generator.
+ Applicable when the xATSGeneratorSettingsCrankCycleEnable OID is enabled.
+ -1 if not available."
+ ::= { xATSGeneratorSettings 8 }
+
+xATSGeneratorSettingsMetricUnit OBJECT-TYPE
+ SYNTAX INTEGER{
+ disabled (1),
+ enabled (2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Specifies the use of metric units in generator related OIDs, as well
+ as on all other interfaces including the generator's local interface."
+ ::= { xATSGeneratorSettings 9 }
+
+-- xATS generator service group
+
+xATSGeneratorServiceTotalRunHoursLifetime OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Total time that the generator engine has been run,
+ over the life of the generator. Measured in hours.
+ -1 if not available."
+ ::= { xATSGeneratorService 1 }
+
+xATSGeneratorServiceEngineStartsLifetime OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Number of engine starts over the life of the generator.
+ -1 if not available."
+ ::= { xATSGeneratorService 2 }
+
+xATSGeneratorServiceTotalkWhLifetime OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Total kWh of operation over the life of the generator.
+ -1 if not available."
+ ::= { xATSGeneratorService 3 }
+
+xATSGeneratorServiceTotalRunHoursSinceMaintanence OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Total time that the generator engine has been run,
+ since last service maintenance. Measured in tenths of hours.
+ -1 if not available."
+ ::= { xATSGeneratorService 4 }
+
+xATSGeneratorServiceEngineStartsSinceMaintanence OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Number of engine starts since last service maintenance.
+ -1 if not available."
+ ::= { xATSGeneratorService 5 }
+
+xATSGeneratorServiceTotalkWhMaintanence OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Total kWh of operation since last service maintenance.
+ -1 if not available."
+ ::= { xATSGeneratorService 6 }
+
+xATSGeneratorServiceResetRecord OBJECT-TYPE
+ SYNTAX INTEGER{
+ yes (1),
+ no (2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Resets the engine start counter, engine run-hours, and kWh values that have
+ accumulated in the generator since last maintenance.
+ Also, the last service date will be reset to the current system date, and
+ any service alarms will be cleared."
+ ::= { xATSGeneratorService 7 }
+
+xATSGeneratorServiceRecordResetDate OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Date at which the generator's service record was reset, in dd-mmm-yyyy format."
+ ::= { xATSGeneratorService 8 }
+
+xATSGeneratorServiceNextServiceDate OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Date at which the next generator service is due in dd-mmm-yyyy format.
+ Based on the xATSGeneratorServiceCalendarIntervalThreshold OID
+ or '' if the calander-based threshold is set to off."
+ ::= { xATSGeneratorService 9 }
+
+xATSGeneratorServiceRunHoursUntilServiceDate OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Runhours until the next generator service is due, in hours.
+ Based on the xATSGeneratorServiceRunHoursThreshold OID
+ or -1 if the runhour-based threshold is set to off."
+ ::= { xATSGeneratorService 10 }
+
+xATSGeneratorServiceRunHoursThreshold OBJECT-TYPE
+ SYNTAX INTEGER{
+ disabled (1),
+ runThreshold100Hours (2),
+ runThreshold150Hours (3),
+ runThreshold200Hours (4),
+ runThreshold250Hours (5),
+ runThreshold300Hours (6),
+ runThreshold400Hours (7),
+ runThreshold500Hours (8)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Runhour-based service interval. When the run-hours since
+ service surpasses this threshold, generator service is due."
+ ::= { xATSGeneratorService 11 }
+
+xATSGeneratorServiceCalendarIntervalThreshold OBJECT-TYPE
+ SYNTAX INTEGER{
+ disabled (1),
+ interval1month (2),
+ interval2month (3),
+ interval3month (4),
+ interval6month (5),
+ intervalyearly (6)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Calander-based service interval. When the next service date,
+ as indicated by the xATSGeneratorServiceNextServiceDate OID
+ is in the past, generator is due for service."
+ ::= { xATSGeneratorService 12 }
+
+-- The xATS Generator Fuel system group
+
+xATSGeneratorFuelSystemType OBJECT-TYPE
+ SYNTAX INTEGER{
+ diesel (1),
+ propane (2),
+ naturalGas (3),
+ unknown (4)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The type of fuel used by the generator."
+ ::= { xATSGeneratorFuelSystem 1 }
+
+xATSGeneratorFuelSystemTankSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Size of the generator's fuel tank.
+ Specified in gallons or liters, based on the value of the
+ xATSGeneratorSettingsMetricUnit OID, or -1 if not available."
+ ::= { xATSGeneratorFuelSystem 2 }
+
+xATSGeneratorFuelSystemFuelLevel OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Fuel remaining in the generator tank.
+ Measured in percent of tank fill, or -1 if if not available."
+ ::= { xATSGeneratorFuelSystem 3 }
+
+xATSGeneratorFuelSystemRuntimePower OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The power value used in the runtime remaining calculation.
+ Measured in tenths of kW, or -1 if not available."
+ ::= { xATSGeneratorFuelSystem 4 }
+
+xATSGeneratorFuelSystemEstimatedRunTime OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "An estimate of available runtime for the generator, based on
+ available fuel as specified in the xATSGeneratorFuelSystemFuelLevel OID
+ and kW load as specified in the xATSGeneratorFuelSystemRuntimePower OID.
+ Measured in tenths of hours, or -1 if not available."
+ ::= { xATSGeneratorFuelSystem 5 }
+
+xATSGeneratorFuelSystemLowRunTimeThreshold OBJECT-TYPE
+ SYNTAX INTEGER{
+ disabled (1),
+ oneHour (2),
+ twoHours (3),
+ threeHours (4),
+ fourHours (5),
+ fiveHours (6),
+ sixHours (7),
+ twelveHours (8),
+ oneDay (9),
+ twoDays (10),
+ threeDays (11),
+ fourDays (12),
+ fiveDays (13),
+ sixDays (14),
+ sevenDays (15)
+
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Threshold below which a low runtime alarm will exist."
+ ::= { xATSGeneratorFuelSystem 6 }
+
+xATSGeneratorFuelSystemVeryLowRunTimeThreshold OBJECT-TYPE
+ SYNTAX INTEGER{
+ disabled (1),
+ oneHour (2),
+ twoHours (3),
+ threeHours (4),
+ fourHours (5),
+ fiveHours (6),
+ sixHours (7),
+ twelveHours (8),
+ oneDay (9),
+ twoDays (10),
+ threeDays (11),
+ fourDays (12),
+ fiveDays (13),
+ sixDays (14),
+ sevenDays (15)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Threshold below which a very low runtime alarm will exist."
+ ::= { xATSGeneratorFuelSystem 7 }
+
+xATSGeneratorFuelSystemLowFuelLevelThreshold OBJECT-TYPE
+ SYNTAX INTEGER (0..100)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Threshold below which a low fuel alarm will exist, with a value of 0 indicating disabled.
+ Specified as percent of tank fill."
+ ::= { xATSGeneratorFuelSystem 8 }
+
+xATSGeneratorFuelSystemVeryLowFuelLevelThreshold OBJECT-TYPE
+ SYNTAX INTEGER (0..100)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Threshold below which a very low fuel alarm will exist, with a value of 0 indicating disabled.
+ Specified as percent of tank fill."
+ ::= { xATSGeneratorFuelSystem 9 }
+
+-- the software group
+-- the powerNetSubAgent group
+-- the powerNetSoftwareSystem group
+
+powerNetSoftwareSystemDescription OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..79))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A brief description of the PowerNet sub-agent."
+ ::= { powerNetSoftwareSystem 1 }
+
+powerNetSoftwareOid OBJECT-TYPE
+ SYNTAX OBJECT IDENTIFIER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The object identifier of the PowerNet sub-agent."
+ ::= { powerNetSoftwareSystem 2 }
+
+-- powerNetSmuxPeer OBJECT IDENTIFIER ::= { powerNetSoftwareOid 1 }
+-- powerNetDPIPeer OBJECT IDENTIFIER ::= { powerNetSoftwareOid 2 }
+
+powerNetSoftwareSystemUpTime OBJECT-TYPE
+ SYNTAX TimeTicks
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The time that the sub-agent has been running."
+ ::= { powerNetSoftwareSystem 3 }
+
+
+-- powerNetSoftwareConfig group
+
+powerNetSoftwareTableSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of software modules supporting the UPS."
+ ::= { powerNetSoftwareConfig 1 }
+
+powerNetSoftwareTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SoftwareEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A list of the software monitoring the UPS."
+ ::= { powerNetSoftwareConfig 2 }
+
+powerNetSoftwareEntry OBJECT-TYPE
+ SYNTAX SoftwareEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "An entry containing information on a software module."
+ INDEX { moduleNumber }
+ ::= { powerNetSoftwareTable 1 }
+
+SoftwareEntry ::=
+ SEQUENCE {
+ moduleNumber
+ INTEGER,
+ moduleName
+ DisplayString,
+ moduleVersion
+ DisplayString,
+ moduleDate
+ DisplayString
+ }
+
+moduleNumber OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index into the Software Entry Table"
+ ::= { powerNetSoftwareEntry 1 }
+
+moduleName OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..79))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The name of the software module."
+ ::= { powerNetSoftwareEntry 2 }
+
+moduleVersion OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..8))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The version of the software module."
+ ::= { powerNetSoftwareEntry 3 }
+
+moduleDate OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..9))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The date of the software module represented as mm-dd-yy."
+ ::= { powerNetSoftwareEntry 4 }
+
+
+-- the ups group
+-- the upsIdent group
+-- the upsBasicIdent
+
+upsBasicIdentModel OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The UPS model name (e.g. 'APC Smart-UPS 600')."
+ ::= { upsBasicIdent 1 }
+
+upsBasicIdentName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "An 8 byte ID string identifying the UPS. This object
+ can be set by the administrator."
+ ::= { upsBasicIdent 2 }
+
+
+-- the upsAdvIdent group
+
+upsAdvIdentFirmwareRevision OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The firmware revision of the UPS system's microprocessor."
+ ::= { upsAdvIdent 1 }
+
+upsAdvIdentDateOfManufacture OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The date when the UPS was manufactured in mm/dd/yy format."
+ ::= { upsAdvIdent 2 }
+
+upsAdvIdentSerialNumber OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "An 8-character string identifying the serial number of
+ the UPS internal microprocessor. This number is set at
+ the factory. NOTE: This number does NOT correspond to
+ the serial number on the rear of the UPS."
+ ::= { upsAdvIdent 3 }
+
+
+
+-- the upsBattery group
+-- the upsBasicBattery group
+
+upsBasicBatteryStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ unknown(1),
+ batteryNormal(2),
+ batteryLow(3)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The status of the UPS batteries. A batteryLow(3)
+ value indicates the UPS will be unable to sustain the
+ current load, and its services will be lost if power is
+ not restored. The amount of run time in reserve at the
+ time of low battery can be configured by the
+ upsAdvConfigLowBatteryRunTime."
+ ::= { upsBasicBattery 1 }
+
+upsBasicBatteryTimeOnBattery OBJECT-TYPE
+ SYNTAX TimeTicks
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The elapsed time since the UPS has switched to battery
+ power."
+ ::= { upsBasicBattery 2 }
+
+upsBasicBatteryLastReplaceDate OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The date when the UPS system's batteries were last replaced
+ in mm/dd/yy format. For Smart-UPS models, this value
+ is originally set in the factory. When the UPS batteries
+ are replaced, this value should be reset by the administrator."
+ ::= { upsBasicBattery 3 }
+
+
+
+-- the upsAdvBattery group
+
+upsAdvBatteryCapacity OBJECT-TYPE
+ SYNTAX Gauge
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The remaining battery capacity expressed in
+ percent of full capacity."
+ ::= { upsAdvBattery 1 }
+
+upsAdvBatteryTemperature OBJECT-TYPE
+ SYNTAX Gauge
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The current internal UPS temperature expressed in
+ Celsius."
+ ::= { upsAdvBattery 2 }
+
+upsAdvBatteryRunTimeRemaining OBJECT-TYPE
+ SYNTAX TimeTicks
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The UPS battery run time remaining before battery
+ exhaustion."
+ ::= { upsAdvBattery 3 }
+
+upsAdvBatteryReplaceIndicator OBJECT-TYPE
+ SYNTAX INTEGER {
+ noBatteryNeedsReplacing(1),
+ batteryNeedsReplacing(2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates whether the UPS batteries need replacing."
+ ::= { upsAdvBattery 4 }
+
+upsAdvBatteryNumOfBattPacks OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of external battery packs connected to the UPS. If
+ the UPS does not use smart cells then the agent reports
+ ERROR_NO_SUCH_NAME."
+ ::= { upsAdvBattery 5 }
+
+upsAdvBatteryNumOfBadBattPacks OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of external battery packs connected to the UPS that
+ are defective. If the UPS does not use smart cells then the
+ agent reports ERROR_NO_SUCH_NAME."
+ ::= { upsAdvBattery 6 }
+
+upsAdvBatteryNominalVoltage OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The nominal battery voltage in Volts."
+ ::= { upsAdvBattery 7 }
+
+upsAdvBatteryActualVoltage OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The actual battery bus voltage in Volts."
+ ::= { upsAdvBattery 8 }
+
+upsAdvBatteryCurrent OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The battery current in Amps."
+ ::= { upsAdvBattery 9 }
+
+upsAdvTotalDCCurrent OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The total DC current in Amps."
+ ::= { upsAdvBattery 10 }
+
+
+-- the upsBasicInput group
+
+upsBasicInputPhase OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The current AC input phase."
+ ::= { upsBasicInput 1 }
+
+
+-- the upsAdvInput group
+
+upsAdvInputLineVoltage OBJECT-TYPE
+ SYNTAX Gauge
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The current utility line voltage in VAC."
+ ::= { upsAdvInput 1 }
+
+upsAdvInputMaxLineVoltage OBJECT-TYPE
+ SYNTAX Gauge
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The maximum utility line voltage in VAC over the
+ previous 1 minute period."
+ ::= { upsAdvInput 2 }
+
+upsAdvInputMinLineVoltage OBJECT-TYPE
+ SYNTAX Gauge
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The minimum utility line voltage in VAC over the
+ previous 1 minute period."
+ ::= { upsAdvInput 3 }
+
+upsAdvInputFrequency OBJECT-TYPE
+ SYNTAX Gauge
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The current input frequency to the UPS system in Hz."
+ ::= { upsAdvInput 4 }
+
+
+upsAdvInputLineFailCause OBJECT-TYPE
+ SYNTAX INTEGER {
+ noTransfer(1),
+ highLineVoltage(2),
+ brownout(3),
+ blackout(4),
+ smallMomentarySag(5),
+ deepMomentarySag(6),
+ smallMomentarySpike(7),
+ largeMomentarySpike(8),
+ selfTest(9),
+ rateOfVoltageChnage(10)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The reason for the occurrence of the last transfer to UPS
+ battery power. The variable is set to:
+ - noTransfer(1) -- if there is no transfer yet.
+ - highLineVoltage(2) -- if the transfer to battery is caused
+ by an over voltage greater than the high transfer voltage.
+ - brownout(3) -- if the duration of the outage is greater than
+ five seconds and the line voltage is between 40% of the
+ rated output voltage and the low transfer voltage.
+ - blackout(4) -- if the duration of the outage is greater than five
+ seconds and the line voltage is between 40% of the rated
+ output voltage and ground.
+ - smallMomentarySag(5) -- if the duration of the outage is less
+ than five seconds and the line voltage is between 40% of the
+ rated output voltage and the low transfer voltage.
+ - deepMomentarySag(6) -- if the duration of the outage is less
+ than five seconds and the line voltage is between 40% of the
+ rated output voltage and ground. The variable is set to
+ - smallMomentarySpike(7) -- if the line failure is caused by a
+ rate of change of input voltage less than ten volts per cycle.
+ - largeMomentarySpike(8) -- if the line failure is caused by
+ a rate of change of input voltage greater than ten volts per cycle.
+ - selfTest(9) -- if the UPS was commanded to do a self test.
+ - rateOfVoltageChange(10) -- if the failure is due to the rate of change of
+ the line voltage."
+ ::= { upsAdvInput 5 }
+
+
+-- the upsBasicOutput group
+
+upsBasicOutputStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ unknown(1),
+ onLine(2),
+ onBattery(3),
+ onSmartBoost(4),
+ timedSleeping(5),
+ softwareBypass(6),
+ off(7),
+ rebooting(8),
+ switchedBypass(9),
+ hardwareFailureBypass(10),
+ sleepingUntilPowerReturn(11),
+ onSmartTrim(12)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The current state of the UPS. If the UPS is unable
+ to determine the state of the UPS this variable is set
+ to unknown(1)."
+ ::= { upsBasicOutput 1 }
+
+upsBasicOutputPhase OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The current output phase."
+ ::= { upsBasicOutput 2 }
+
+
+-- the upsAdvOutput group
+
+upsAdvOutputVoltage OBJECT-TYPE
+ SYNTAX Gauge
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The output voltage of the UPS system in VAC."
+ ::= { upsAdvOutput 1 }
+
+upsAdvOutputFrequency OBJECT-TYPE
+ SYNTAX Gauge
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The current output frequency of the UPS system in Hz."
+ ::= { upsAdvOutput 2 }
+
+upsAdvOutputLoad OBJECT-TYPE
+ SYNTAX Gauge
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The current UPS load expressed in percent
+ of rated capacity."
+ ::= { upsAdvOutput 3 }
+
+upsAdvOutputCurrent OBJECT-TYPE
+ SYNTAX Gauge
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The current in amperes drawn by the load on the UPS."
+ ::= { upsAdvOutput 4 }
+
+
+-- the upsBasicConfig group
+
+upsBasicConfigNumDevices OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of devices that are plugged into the UPS."
+ ::= { upsBasicConfig 1 }
+
+upsBasicConfigDeviceTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF UpsBasicConfigDeviceEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A list of devices that are plugged into the UPS.
+ The number of entries is given by the value of
+ upsBasicConfigNumDevices."
+ ::= { upsBasicConfig 2 }
+
+upsBasicConfigDeviceEntry OBJECT-TYPE
+ SYNTAX UpsBasicConfigDeviceEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The devices plugged in to the UPS."
+ INDEX { deviceIndex }
+ ::= { upsBasicConfigDeviceTable 1 }
+
+UpsBasicConfigDeviceEntry ::=
+ SEQUENCE {
+ deviceIndex
+ INTEGER,
+ deviceName
+ DisplayString,
+ vaRating
+ INTEGER,
+ acceptThisDevice
+ INTEGER
+ }
+
+deviceIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index of the device that is plugged into the UPS."
+ ::= { upsBasicConfigDeviceEntry 1 }
+
+deviceName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The name/description of the device plugged into the UPS."
+ ::= { upsBasicConfigDeviceEntry 2 }
+
+vaRating OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The volt-amp rating of the device plugged into the UPS."
+ ::= { upsBasicConfigDeviceEntry 3 }
+
+acceptThisDevice OBJECT-TYPE
+ SYNTAX INTEGER {
+ yes(1),
+ no(2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "An entry is added if yes, the entry is deleted if no."
+ ::= { upsBasicConfigDeviceEntry 4 }
+
+
+
+
+-- the upsAdvConfig group
+
+upsAdvConfigRatedOutputVoltage OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The nominal output voltage from the UPS in VAC.
+
+ For a list of allowed values supported by your UPS model,
+ see the UPS User's Manual.
+
+ If a value other than a supported value is provided in a
+ set request, the UPS interprets it as the next lower
+ acceptable value. If the provided value is lower than
+ the lowest acceptable value, the lowest acceptable
+ value is used."
+ ::= { upsAdvConfig 1 }
+
+upsAdvConfigHighTransferVolt OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The maximum line voltage in VAC allowed before the
+ UPS system transfers to battery backup.
+
+ For a list of allowed values supported by your UPS model,
+ see the UPS User's Manual.
+
+ If a value other than a supported value is provided in a
+ set request, the UPS interprets it as a the next higher
+ acceptable value. If the provided value is higher than
+ the highest acceptable value, the highest acceptable
+ value is used."
+ ::= { upsAdvConfig 2 }
+
+upsAdvConfigLowTransferVolt OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The minimum line voltage in VAC allowed before the
+ UPS system transfers to battery backup.
+
+ For a list of allowed values supported by your UPS model,
+ see the UPS User's Manual.
+
+ If a value other than a supported value is provided in a
+ set request, the UPS interprets it as the next lower
+ acceptable value. If the provided value is lower than
+ the lowest acceptable value, the lowest acceptable
+ value is used."
+ ::= { upsAdvConfig 3 }
+
+upsAdvConfigAlarm OBJECT-TYPE
+ SYNTAX INTEGER {
+ timed(1),
+ atLowBattery(2),
+ never(3),
+ mute(4)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "A flag indicating how the UPS should handle audible
+ line fail alarms:
+ timed(1): UPS alarm will sound after a preset timed duration starting
+ from the line fail condition (see OID upsAdvConfigAlarmTimer for the
+ alarm timer value)
+ atLowBattery(2): UPS alarm will sound when the UPS has reached a Low
+ Battery condition during a line fail
+ never(3): Disables the UPS audible alarm
+ mute(4): Mutes the current alarm for some UPSs only when it is in an
+ alarm state and will return to the previously configured option when
+ the UPS recovers from the alarm condition"
+ ::= { upsAdvConfig 4 }
+
+upsAdvConfigAlarmTimer OBJECT-TYPE
+ SYNTAX TimeTicks
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The time after initial line failure at which the UPS
+ begins emitting audible alarms (beeping). This timer is
+ observed only if the value of extControlAlarm is timed(2).
+ Allowed values are 0 or 30 seconds.
+
+ If a value other than a supported value is provided in a
+ set request, the UPS interprets it as a the next lower
+ acceptable value. If the provided value is lower than
+ the lowest acceptable value, the lowest acceptable
+ value is used."
+ ::= { upsAdvConfig 5 }
+
+upsAdvConfigMinReturnCapacity OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The minimum battery capacity required before the UPS will
+ return from a low battery shutdown condition. The capacity is
+ measured from 0% battery capacity (or Low Battery) as a percent
+ of full capacity (100%). In other words, the UPS will not re-energize
+ the output until the battery has charged so that its' capacity is equal
+ to this value.
+
+ For a list of allowed values supported by your UPS model,
+ see the UPS User's Manual.
+
+ If a value other than a supported value is provided in a
+ set request, the UPS interprets it as a the next higher
+ acceptable value. If the provided value is higher than
+ the highest acceptable value, the highest acceptable
+ value is used."
+ ::= { upsAdvConfig 6 }
+
+upsAdvConfigSensitivity OBJECT-TYPE
+ SYNTAX INTEGER {
+ auto(1),
+ low(2),
+ medium(3),
+ high(4)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The sensitivity of the UPS to utility line abnormalities
+ or noises."
+ ::= { upsAdvConfig 7 }
+
+upsAdvConfigLowBatteryRunTime OBJECT-TYPE
+ SYNTAX TimeTicks
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The desired run time of the UPS, in seconds, once the
+ low battery condition is reached. During this time the UPS will
+ produce a constant warning tone which can not be disabled.
+
+ For a list of allowed values supported by your UPS model,
+ see the UPS User's Manual.
+
+ If a value other than a supported value is provided in a set
+ request, the UPS interprets the value as the next higher
+ acceptable value. If the provided value is higher than the
+ highest acceptable value, the highest acceptable value is used."
+ ::= { upsAdvConfig 8 }
+
+upsAdvConfigReturnDelay OBJECT-TYPE
+ SYNTAX TimeTicks
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The delay in seconds after utility line power returns
+ before the UPS will turn on. This value is also used
+ when the UPS comes out of a reboot and before the UPS
+ wakes up from 'sleep' mode.
+
+ For a list of allowed values supported by your UPS model,
+ see the UPS User's Manual.
+
+ If a value other than a supported value is provided in a
+ set request, the UPS interprets it as a the next higher
+ acceptable value. If the provided value is higher than
+ the highest acceptable value, the highest acceptable
+ value is used."
+ ::= { upsAdvConfig 9 }
+
+upsAdvConfigShutoffDelay OBJECT-TYPE
+ SYNTAX TimeTicks
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The delay in seconds the UPS remains on after being told
+ to turn off.
+
+ For a list of allowed values supported by your UPS model,
+ see the UPS User's Manual.
+
+ If a value other than a supported value is provided in a
+ set request, the UPS interprets it as a the next higher
+ acceptable value. If the provided value is higher than
+ the highest acceptable value, the highest acceptable
+ value is used."
+ ::= { upsAdvConfig 10 }
+
+upsAdvConfigUpsSleepTime OBJECT-TYPE
+ SYNTAX TimeTicks
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The time in seconds for the UPS to go to 'sleep' when
+ instructed. When in sleep mode, the UPS will not provide
+ output power regardless of the input line state. Once the
+ specified time has elapsed, output power will be restored.
+
+ This is a configuration setting. The UPS will not go to
+ sleep until told to do so by the manager from a management
+ station.
+
+ Any input value is allowed, however the UPS only recognizes
+ 1/10 of an hour increments. The provided value will be
+ rounded to the closest 1/10 of an hour with one exception:
+ Any value entered between 1 and 540 seconds will be rounded
+ to 360 seconds (or 6 minutes)."
+ ::= { upsAdvConfig 11 }
+
+
+upsAdvConfigSetEEPROMDefaults OBJECT-TYPE
+ SYNTAX INTEGER {
+ noSetEEPROMDefaults(1),
+ setEEPROMDefaults(2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "WRITE: Resets the UPS EEPROM variables to default values.
+ READ: returns 0"
+ ::= { upsAdvConfig 12 }
+
+upsAdvConfigDipSwitchSetting OBJECT-TYPE
+ SYNTAX SEQUENCE OF UpsAdvConfigDipSwitchEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Current settings of UPS dip switches."
+ ::= { upsAdvConfig 13 }
+
+upsAdvConfigDipSwitchEntry OBJECT-TYPE
+ SYNTAX UpsAdvConfigDipSwitchEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The current setting of one dip switch."
+ INDEX { dipSwitchIndex }
+ ::= { upsAdvConfigDipSwitchSetting 1 }
+
+UpsAdvConfigDipSwitchEntry ::=
+ SEQUENCE {
+ dipSwitchIndex
+ INTEGER,
+ dipSwitchStatus
+ INTEGER
+ }
+
+dipSwitchIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index of a UPS dip switch."
+ ::= { upsAdvConfigDipSwitchEntry 1 }
+
+dipSwitchStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ on(1),
+ off(2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The setting of a UPS dip switch."
+ ::= { upsAdvConfigDipSwitchEntry 2 }
+
+upsAdvConfigBattExhaustThresh OBJECT-TYPE
+ SYNTAX TimeTicks
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The number of seconds prior to battery exhaustion when the
+ UPS will switch off power to its load."
+ ::= { upsAdvConfig 14 }
+
+upsAdvConfigPassword OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The password entered at the UPS front panel to enable local
+ configuration of the EEProm. If the password is disabled or
+ is not supported, then the agent returns a null string."
+ ::= { upsAdvConfig 15 }
+
+upsAdvConfigAllowedSetTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ApcUpsConfigEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The table listing the allowed values for all discrete
+ configurable UPS variables."
+ ::= { upsAdvConfig 16 }
+
+apcUpsConfigEntry OBJECT-TYPE
+ SYNTAX ApcUpsConfigEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The table entry for a configurable UPS variable."
+ INDEX { apcUpsConfigFieldIndex }
+ ::= { upsAdvConfigAllowedSetTable 1 }
+
+ApcUpsConfigEntry ::= SEQUENCE {
+ apcUpsConfigFieldIndex INTEGER,
+ apcUpsConfigFieldOID OBJECT IDENTIFIER,
+ apcUpsConfigFieldValueRange DisplayString
+ }
+
+apcUpsConfigFieldIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to an eeprom field entry."
+ ::= { apcUpsConfigEntry 1 }
+
+apcUpsConfigFieldOID OBJECT-TYPE
+ SYNTAX OBJECT IDENTIFIER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The OID of the current configurable value."
+ ::= { apcUpsConfigEntry 2 }
+
+apcUpsConfigFieldValueRange OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The discrete set of allowed values of a configurable
+ register. Individual values are delimited by a comma."
+ ::= { apcUpsConfigEntry 3 }
+
+upsAdvConfigBattCabAmpHour OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Configure settings of UPS battery cabinet amp hour setting."
+ ::= { upsAdvConfig 17 }
+
+upsAdvConfigPositionSelector OBJECT-TYPE
+ SYNTAX INTEGER {
+ unknown (1),
+ rack (2),
+ tower (3)
+ }
+
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Configure UPS position selector. If the UPS doesn't
+ support this configuration it will report unknown (1).
+ The positions are either rack (2) for rack mounted or
+ tower (3) for tower unit."
+ ::= { upsAdvConfig 18 }
+
+upsAdvConfigOutputFreqRange OBJECT-TYPE
+ SYNTAX INTEGER {
+ unknown (1),
+ freqRangeAUTO (2),
+ freqRange60Var1 (3),
+ freqRange60Var3 (4),
+ freqRange50Var1 (5),
+ freqRange50Var3 (6),
+ freqRange60Var10 (7),
+ freqRange50Var10 (8)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Configure the output frequency tolerance range.
+ unknown(1) indicates the output frequency is unknown.
+ freqRangeAUTO(2) configure the output frequency range for automatic.
+ freqRange60Var1(3) configure the output frequency range for 60 +/- 0.1 Hz
+ freqRange60Var3(4) configure the output frequency range for 60 +/- 3.0 Hz
+ freqRange50Var1(5) configure the output frequency range for 50 +/- 0.1 Hz
+ freqRange50Var3(6) configure the output frequency range for 50 +/- 3.0 Hz
+ freqRange60Var10(7) configure the output frequency range for 60 +/- 10 Hz
+ freqRange50Var10(8) configure the output frequency range for 50 +/- 10 Hz"
+ ::= { upsAdvConfig 19 }
+
+upsAdvConfigUPSFail OBJECT-TYPE
+ SYNTAX INTEGER {
+ unknown (1),
+ gotoBypass (2),
+ dropLoad (3)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Configure the UPS fail action. If UPS fails,
+ and frequency or voltage is out of range it will either
+ GotoBypass (2) or DropLoad (3). This OID will report
+ unknown (1) if it is not supported feature or option."
+ ::= { upsAdvConfig 20 }
+
+upsAdvConfigAlarmRedundancy OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Configure settings of UPS alarm if the redundancy is
+ under the current redundancy. Use -1 for never."
+ ::= { upsAdvConfig 21 }
+
+upsAdvConfigAlarmLoadOver OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Configure settings of UPS alarm if the load is
+ over the current load in kVA. Use -1 for never."
+ ::= { upsAdvConfig 22 }
+
+upsAdvConfigAlarmRuntimeUnder OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Configure settings of UPS alarm if the runtime is
+ under the current time of minutes. Use -1 for never."
+ ::= { upsAdvConfig 23 }
+
+upsAdvConfigVoutReporting OBJECT-TYPE
+ SYNTAX INTEGER {
+ unknown (1),
+ voutAUTO (2),
+ vout208 (3),
+ vout240 (4)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Configure the way the UPS scales its output voltage readings.
+ unknown(1) indicates the Vout Reporting is unknown.
+ voutAUTO(2) configure the Vout Reporting for automatic scalling.
+ vout208(3) configure the Vout Reporting for 208 Volts.
+ vout240(4) configure the Vout Reporting for 240 Volts."
+ ::= { upsAdvConfig 24 }
+
+upsAdvConfigNumExternalBatteries OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Configure the number of external batteries connected to the UPS."
+ ::= { upsAdvConfig 25 }
+
+upsAdvConfigSimpleSignalShutdowns OBJECT-TYPE
+ SYNTAX INTEGER {
+ unknown (1),
+ disabled (2),
+ enabled (3)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Configure Simple Signal shutdown commands from the Simple Signal
+ port to be issued to the UPS.
+ unknown(1) indicates the Simple Signal Shutdown setting is unknown.
+ disabled(2) configure to disable Simple Signal Shutdowns.
+ enabled(3) configure to enable Simple Signal Shutdowns."
+ ::= { upsAdvConfig 26 }
+
+
+-- the upsSyncCtrlGroupConfig group
+
+upsSCGMembershipGroupNumber OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The SCG Membership Group number (MGN) is a 16-bit number allowing
+ up to 65534 separate groups that can be identified and distinguished
+ per IP subnet. Zero and 65535 are not used. The MGN is used in all
+ communication between members of the SCG and a Network Management Card
+ (NMC) will listen and only respond to commands sent to it using its
+ configured SCG ID."
+ ::= { upsSyncCtrlGroupConfig 1 }
+
+upsSCGActiveMembershipStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ enabledSCG (1),
+ disabledSCG (2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Membership in the configured SCG can be enabled and
+ disabled. If an NMC is configured for an SCG, but
+ has its membership disabled, all synchronized control commands
+ received will be ignored."
+ ::= { upsSyncCtrlGroupConfig 2 }
+
+upsSCGPowerSynchronizationDelayTime OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The Power Synchronization Delay Time (PSD) setting is the maximum
+ number of seconds an SCG Initiator will wait for all SCG members to
+ recover utility power before completing the reboot sequence of a
+ reboot or sleep command. If all SCG members are ready to proceed,
+ no additional delay is introduced."
+ ::= { upsSyncCtrlGroupConfig 3 }
+
+upsSCGReturnBatteryCapacityOffset OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "A reboot command uses the Initiator’s Return battery Capacity (RBC) to control
+ when the SCG completes this operation. In a Normal Control Operation (NCC) the
+ UPS will only complete the reboot if RBC is reached. Due to normal battery
+ charge rate variations it may be desirable for the Followers to complete the
+ reboot if they are within some range of the Initiator’s RBC when the Initiator
+ is prepared (charged to RBC) to complete the reboot. The Return Battery
+ Capacity Offset (RBCO) defines a percent battery capacity subtracted from an
+ RBC above which a Follower’s battery must be charged for it to complete a
+ reboot. For example, if the Initiator’s RBC is 50% and the Initiator’s RBCO is
+ 5% then a Follower’s battery capacity is within range if it is greater or equal
+ to 45% (50% - 5%) at the time when the Initiator tries to complete the reboot
+ command. The default RBCO is 10%. "
+ ::= { upsSyncCtrlGroupConfig 4 }
+
+upsSCGMultiCastIP OBJECT-TYPE
+ SYNTAX IpAddress
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The MultiCast IP address of the SCG Group."
+ ::= { upsSyncCtrlGroupConfig 5 }
+
+-- the upsSyncCtrlGroupStatus group
+
+upsSCGNumOfGroupMembers OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of active, communicating members in the Sync Control Group (SCG).
+ This variable indicates the number of rows in the SCG Status Table."
+ ::= { upsSyncCtrlGroupStatus 1 }
+
+-- Sync Control Group Status Table
+
+upsSCGStatusTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF UpsSCGStatusEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A list of SCG status table entries. The number of entries
+ is given by the value of upsSCGNumOfGroupMembers."
+ ::= { upsSyncCtrlGroupStatus 2 }
+
+ upsSCGStatusEntry OBJECT-TYPE
+ SYNTAX UpsSCGStatusEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "An entry containing information applicable to a
+ particular SCG Member."
+ INDEX { upsSCGStatusTableIndex }
+ ::= { upsSCGStatusTable 1 }
+
+ UpsSCGStatusEntry ::= SEQUENCE {
+ upsSCGStatusTableIndex INTEGER,
+ upsSCGMemberIP IpAddress,
+ upsSCGACInputStatus INTEGER,
+ upsSCGACOutputStatus INTEGER
+ }
+
+ upsSCGStatusTableIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index of a status entry for an active, communicating SCG member."
+ ::= { upsSCGStatusEntry 1 }
+
+ upsSCGMemberIP OBJECT-TYPE
+ SYNTAX IpAddress
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The IP address of an active, communicating SCG Member."
+ ::= { upsSCGStatusEntry 2 }
+
+ upsSCGACInputStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ acInGood(1),
+ acInBad(2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This OID indicates the AC Input Status of the SCG Member.
+ acInGood(1) indicates the AC Input is within tolerance.
+ acInBad(2) indicates the AC Input is not within tolerance."
+ ::= { upsSCGStatusEntry 3 }
+
+ upsSCGACOutputStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ acOutOn(1),
+ acOutOff(2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This OID indicates the AC Output Status of the SCG Member.
+ acOutOn(1) indicates the UPS output is providing power to the load.
+ acOutOff(2) indicates the UPS output is not providing power to the load. "
+ ::= { upsSCGStatusEntry 4 }
+
+-- the upsBasicState group
+
+upsBasicStateOutputState OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "An ASCII string containing the 64 flags representing
+ the current state(s) of the UPS. If the Network Card
+ is unable to determine the state of the UPS, this
+ variable is set to ‘UNKNOWN’.
+
+ The flags are numbered 1 to 64, read from left to
+ right. The flags are defined as follows:
+
+ Flag 1: Abnormal Condition Present
+ Flag 2: On Battery
+ Flag 3: Low Battery
+ Flag 4: On Line
+
+ Flag 5: Replace Battery
+ Flag 6: Serial Communication Established
+ Flag 7: AVR Boost Active*
+ Flag 8: AVR Trim Active*
+
+ Flag 9: Overload
+ Flag 10: Runtime Calibration
+ Flag 11: Batteries Discharged
+ Flag 12: Manual Bypass
+
+ Flag 13: Software Bypass
+ Flag 14: In Bypass due to Internal Fault
+ Flag 15: In Bypass due to Supply Failure*
+ Flag 16: In Bypass due to Fan Failure*
+
+ Flag 17: Sleeping on a Timer
+ Flag 18: Sleeping until Utility Power Returns
+ Flag 19: On
+ Flag 20: Rebooting
+
+ Flag 21: Battery Communication Lost*
+ Flag 22: Graceful Shutdown Initiated
+ Flag 23: Smart Boost or Smart Trim Fault*
+ Flag 24: Bad Output Voltage*
+
+ Flag 25: Battery Charger Failure*
+ Flag 26: High Battery Temperature
+ Flag 27: Self Test In Progress
+ Flag 28: Low Battery / On Battery
+
+ Flag 29: Graceful Shutdown Issued by Upstream Device
+ Flag 30: Graceful Shutdown Issued by Downstream Device
+ Flag 31: No Batteries Attached*
+ Flag 32: Synchronized command is in progress
+
+ Flag 33: <Not Used>
+ Flag 34: <Not Used>
+ Flag 35: <Not Used>
+ Flag 36: <Not Used>
+
+ Flag 37: <Not Used>
+ Flag 38: <Not Used>
+ Flag 39: <Not Used>
+ Flag 40: <Not Used>
+
+ Flag 41: <Not Used>
+ Flag 42: <Not Used>
+ Flag 43: <Not Used>
+ Flag 44: <Not Used>
+
+ Flag 45: <Not Used>
+ Flag 46: <Not Used>
+ Flag 47: <Not Used>
+ Flag 48: <Not Used>
+
+ Flag 49: <Not Used>
+ Flag 50: <Not Used>
+ Flag 51: <Not Used>
+ Flag 52: <Not Used>
+
+ Flag 53: <Not Used>
+ Flag 54: <Not Used>
+ Flag 55: <Not Used>
+ Flag 56: <Not Used>
+
+ Flag 57: <Not Used>
+ Flag 58: <Not Used>
+ Flag 59: <Not Used>
+ Flag 60: <Not Used>
+
+ Flag 61: <Not Used>
+ Flag 62: <Not Used>
+ Flag 63: <Not Used>
+ Flag 64: <Not Used>"
+
+ ::= { upsBasicState 1 }
+
+-- the upsAdvState group
+
+upsAdvStateAbnormalConditions OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "An ASCII string containing the 32 flags representing
+ the current active UPS faults. If the Network Card
+ is unable to determine the values of the flags, this
+ variable is set to ‘UNKNOWN’. If this variable is not
+ supported by the connected UPS, this variable is set to
+ ‘NOT SUPPORTED’.
+
+ The flags are numbered from 1 to 32, and read from left to
+ right. The flags are defined as follows:
+
+ Flag 1: Power Module Failure
+ Flag 2: Main Intelligence Module Failure
+ Flag 3: Redundant Intelligence Module Failure
+ Flag 4: Battery Failure
+
+ Flag 5: Load(kVA) Alarm Threshold Violation
+ Flag 6: Redundancy Lost
+ Flag 7: Redundancy Below Alarm Threshold
+ Flag 8: Bypass notin Range; Either Frequency or Voltage
+
+ Flag 9: Bypass Contactor Stuck in Bypass Condition
+ Flag 10: Bypass Contactor Stuck in On-Line Condition
+ Flag 11: In Bypass due to an Internal Fault
+ Flag 12: In Bypass due to an Overload
+
+ Flag 13: In Maintanence Bypass
+ Flag 14: Input Circuit Braker Tripped Open
+ Flag 15: System Level Fan Failure
+ Flag 16: Redundant Intelligent Module in Control
+
+ Flag 17: IIC Inter-Module Communication Failure
+ Flag 18: No Working Power Modules
+ Flag 19: Load Shutdown From Bypass; Input Frequency
+ Flag 20: Runtime Below Alarm Threshold
+
+ Flag 21: Extended Run Frame Fault
+ Flag 22: Output Voltage out of Range
+ Flag 23: UPS Not Synchronized
+ Flag 24: No Batteries Installed
+
+ Flag 25: Battery Voltage High
+ Flag 26: UPS Specific Fault Detected
+ Flag 27: Site Wiring Fault
+ Flag 28: Backfeed Protection Relay Opened
+
+ Flag 29: <Not Used>
+ Flag 30: <Not Used>
+ Flag 31: <Not Used>
+ Flag 32: <Not Used>"
+ ::= { upsAdvState 1 }
+
+upsAdvStateSymmetra3PhaseSpecificFaults OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "An ASCII string containing the 64 flags representing
+ the current active UPS specific faults for the Symmetra
+ 3-Phase UPS models. If the Network Card is unable to
+ determine the values of the flags, this variable is set
+ to ‘UNKNOWN’. If the connected UPS does not use this
+ variable, it is set to ‘NOT SUPPORTED’.
+
+ The flags are numbered from 1 to 64, and read from left
+ to right. The bits are defined as follows:
+
+ Flag 1: External Switch Gear Failure
+ Flag 2: External Transformer Over Temperature
+ Flag 3: External DC Circuit Breaker Tripped
+ Flag 4: System Power Supply Failure
+
+ Flag 5: Battery Monitor Card Failure
+ Flag 6: Battery Monitor Card Removed
+ Flag 7: XR Communication Card Failure
+ Flag 8: XR Communication Card Removed
+
+ Flag 9: External Switch Gear Monitoring Card Failure
+ Flag 10: External Switch Gear Monitoring Card Removed
+ Flag 11: Internal DC Circiut Breaker Tripped
+ Flag 12: Static Bypass Switch Failure
+
+ Flag 13: System EEPROM Removed
+ Flag 14: System EEPROM Failure
+ Flag 15: UPS in Forced Bypass
+ Flag 16: <Not Used>
+
+ Flag 17: <Not Used>
+ Flag 18: <Not Used>
+ Flag 19: <Not Used>
+ Flag 20: <Not Used>
+
+ Flag 21: <Not Used>
+ Flag 22: <Not Used>
+ Flag 23: <Not Used>
+ Flag 24: <Not Used>
+
+ Flag 25: <Not Used>
+ Flag 26: <Not Used>
+ Flag 27: <Not Used>
+ Flag 28: <Not Used>
+
+ Flag 29: <Not Used>
+ Flag 30: <Not Used>
+ Flag 31: <Not Used>
+ Flag 32: <Not Used>
+
+ Flag 33: <Not Used>
+ Flag 34: <Not Used>
+ Flag 35: <Not Used>
+ Flag 36: <Not Used>
+
+ Flag 37: <Not Used>
+ Flag 38: <Not Used>
+ Flag 39: <Not Used>
+ Flag 40: <Not Used>
+
+ Flag 41: <Not Used>
+ Flag 42: <Not Used>
+ Flag 43: <Not Used>
+ Flag 44: <Not Used>
+
+ Flag 45: <Not Used>
+ Flag 46: <Not Used>
+ Flag 47: <Not Used>
+ Flag 48: <Not Used>
+
+ Flag 49: <Not Used>
+ Flag 50: <Not Used>
+ Flag 51: <Not Used>
+ Flag 52: <Not Used>
+
+ Flag 53: <Not Used>
+ Flag 54: <Not Used>
+ Flag 55: <Not Used>
+ Flag 56: <Not Used>
+
+ Flag 57: <Not Used>
+ Flag 58: <Not Used>
+ Flag 59: <Not Used>
+ Flag 60: <Not Used>
+
+ Flag 61: <Not Used>
+ Flag 62: <Not Used>
+ Flag 63: <Not Used>
+ Flag 64: <Not Used>"
+ ::= { upsAdvState 2 }
+
+upsAdvStateDP300ESpecificFaults OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "An ASCII string containing the 64 flags representing
+ the current active UPS specific faults for the Silcon
+ DP300E UPS models. If the Network Card is unable to
+ determine the values of the flags, this variable is set
+ to ‘UNKNOWN’. If the connected UPS does not use this
+ variable, it is set to ‘NOT SUPPORTED’.
+
+ The flags are numbered from 1 to 64, and read from left
+ to right. The bits are defined as follows:
+
+ Flag 1: Peak Current Limiter Avtive
+ Flag 2: Bypass Power Supply Fault
+ Flag 3: Delta Current LImiter Active
+ Flag 4: Fan Fault
+
+ Flag 5: High DC warning
+ Flag 6: Inverter Voltage Error
+ Flag 7: Parallel Synchronization Error
+ Flag 8: Second Power Supply Fault
+
+ Flag 9: Internal Power Supply Fault
+ Flag 10: <Not Used>
+ Flag 11: <Not Used>
+ Flag 12: <Not Used>
+
+ Flag 13: <Not Used>
+ Flag 14: Bypass Static Switch High Temperature
+ Flag 15: High Battery Temperature
+ Flag 16: Battery Weak
+
+ Flag 17: <Not Used>
+ Flag 18: System Locked in Operation Mode
+ Flag 19: RAM1 Memory Write Error
+ Flag 20: Memory Write Error
+
+ Flag 21: Communication to VQ Bypass Lost
+ Flag 22: Communication to VQ Output Lost
+ Flag 23: Communication to DMU Lost
+ Flag 24: Communication to Controller Lost
+
+ Flag 25: Communication to Parallel IF Lost
+ Flag 26: External Shutdown Accepted
+ Flag 27: DC Capacitor Charge Error
+ Flag 28: Communication to VQ Mains Lost
+
+ Flag 29: Bypass Synchronization Error
+ Flag 30: Charge Error
+ Flag 31: <Not Used>
+ Flag 32: <Not Used>
+
+ Flag 33: <Not Used>
+ Flag 34: <Not Used>
+ Flag 35: <Not Used>
+ Flag 36: <Not Used>
+
+ Flag 37: <Not Used>
+ Flag 38: <Not Used>
+ Flag 39: <Not Used>
+ Flag 40: <Not Used>
+
+ Flag 41: <Not Used>
+ Flag 42: <Not Used>
+ Flag 43: <Not Used>
+ Flag 44: <Not Used>
+
+ Flag 45: <Not Used>
+ Flag 46: <Not Used>
+ Flag 47: <Not Used>
+ Flag 48: <Not Used>
+
+ Flag 49: <Not Used>
+ Flag 50: <Not Used>
+ Flag 51: <Not Used>
+ Flag 52: <Not Used>
+
+ Flag 53: <Not Used>
+ Flag 54: <Not Used>
+ Flag 55: <Not Used>
+ Flag 56: <Not Used>
+
+ Flag 57: <Not Used>
+ Flag 58: <Not Used>
+ Flag 59: <Not Used>
+ Flag 60: <Not Used>
+
+ Flag 61: <Not Used>
+ Flag 62: <Not Used>
+ Flag 63: <Not Used>
+ Flag 64: <Not Used>"
+ ::= { upsAdvState 3 }
+
+
+-- the upsBasicControl group
+
+upsBasicControlConserveBattery OBJECT-TYPE
+ SYNTAX INTEGER {
+ noTurnOffUps(1),
+ turnOffUpsToConserveBattery(2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Setting this variable to turnUpsOffToConserveBattery(2)
+ causes a UPS on battery to be put into 'sleep' mode. The
+ UPS will turn back on when utility power is restored.
+ Attempting to turn off a UPS that is not on battery will
+ result in a badValue error.
+
+ Setting this value to noTurnOffUps(1) has no
+ effect.
+
+ The value noTurnOffUps(1) will always be returned
+ when the variable is read."
+::= { upsBasicControl 1 }
+
+
+
+-- the upsAdvControl group
+
+upsAdvControlUpsOff OBJECT-TYPE
+ SYNTAX INTEGER {
+ noTurnUpsOff(1),
+ turnUpsOff(2),
+ turnUpsOffGracefully(3),
+ turnUpsSyncGroupOff(4),
+ turnUpsSyncGroupOffAfterDelay(5),
+ turnUpsSyncGroupOffGracefully(6)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Setting this variable to turnUpsOff(2) causes
+ the UPS to shut off. When in this state, the UPS
+ will not provide output power regardless of the input
+ line state.
+
+ Setting this variable to turnUpsOffGracefully(3) causes
+ the UPS to shut off after a delay period. This allows the
+ host to shut down in a graceful manner. When in this state,
+ the UPS will not provide output power regardless of the
+ input line state.
+
+ If this UPS is an active member of a Synchronized
+ Control Group (SCG) the turnUpsSyncGroupOff(4) command
+ will perform a Synchronized Turn Off of all active Group
+ members regardless of their current AC output status.
+
+ If this UPS is an active member of a Synchronized
+ Control Group (SCG) the turnUpsSyncGroupOffAfterDelay(5)
+ command will perform a Synchronized Turn Off After Delay
+ of all active Group members regardless of their current
+ AC output status. This unit's Shutdown Delay will be used
+ to execute the Turn Off After Delay command.
+
+ If this UPS is an active member of an SCG, the
+ turnUpsSyncGroupOffGracefully(6) command will perform a
+ Synchronized Turn Off Gracefully of all active Group
+ members regardless of their current AC output status.
+ This unit's Maximum Shutdown Time and Shutdown Delay will
+ be used to execute the Turn Off Gracefully command.
+
+ Setting this value to noTurnUpsOff(1) has no
+ effect.
+
+ The value noTurnUpsOff(1) will always be returned
+ when the variable is read."
+ ::= { upsAdvControl 1 }
+
+upsAdvControlRebootUps OBJECT-TYPE
+ SYNTAX INTEGER {
+ noRebootUps(1),
+ rebootUps(2),
+ rebootUpsGracefully(3),
+ rebootSyncGroupUps(4),
+ rebootSyncGroupUpsGracefully(5)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Setting this variable to rebootUps(2) causes the
+ UPS to shut off and turn back on.
+
+ Setting this variable to rebootUpsGracefully(3) causes the
+ UPS to shut off and turn back on after a delay period.
+ This allows the host to shut down in a graceful manner.
+
+ If this UPS is an active member of a Synchronized Control
+ Group (SCG) the rebootSyncGroupUps(4) command will perform
+ a Synchronized Reboot of all active Group members regardless
+ of their current AC output status. This unit's Power
+ Synchronization Delay, Shutdown Delay, Return Delay,
+ Return Battery Capacity, and Return Battery Capacity Offset
+ will be used to execute the Reboot command.
+
+ If this UPS is an active member of a SCG the
+ rebootSyncGroupUpsGracefully(5) command will perform a
+ Synchronized Reboot of all active Group members regardless
+ of their current AC output status. This unit's Power
+ Synchronization Delay, Maximum Shutdown Time,
+ Shutdown Delay, Return Delay, Return Battery Capacity, and
+ Return Battery Capacity Offset will be used
+ to execute the Reboot command.
+
+ Setting this value to noRebootUps(1) has no effect.
+
+ The value noRebootUps(1) will always be returned
+ when the variable is read."
+ ::= { upsAdvControl 2 }
+
+upsAdvControlUpsSleep OBJECT-TYPE
+ SYNTAX INTEGER {
+ noPutUpsToSleep(1),
+ putUpsToSleep(2),
+ putUpsToSleepGracefully(3),
+ putUpsSyncGroupToSleep(4),
+ putUpsSyncGroupToSleepGracefully(5)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Setting this variable to putUpsToSleep(2) causes
+ the UPS to go to sleep for the time specified by
+ upsAdvConfigUpsSleepTime.
+
+ Setting this variable to putUpsToSleepGracefully(3)
+ causes the UPS to go to sleep for the time specified
+ by upsAdvConfigUpsSleepTime after a delay period.
+ This allows the host to shut down in a graceful manner.
+
+ If this UPS is an active member of a Synchronized Control
+ Group (SCG), the putUpsSyncGroupToSleep(4) command will perform
+ a Synchronized Sleep of all active Group members regardless
+ of their current AC output status. This unit's Power
+ Synchronization Delay, Shutdown Delay, Sleep Time,
+ and Return Delay will be used to execute the sleep command.
+
+ If this UPS is an active member of a SCG the
+ putUpsSyncGroupToSleepGracefully(5) command will perform a
+ Synchronized Sleep Gracefully of all active Group members
+ regardless of their current AC output status. This unit's
+ Power Synchronization Delay, Maximum Shutdown Time, Shutdown
+ Delay, Sleep Time, and Return Delay to execute the sleep
+ command.
+
+ When in sleep mode, the UPS will not provide output
+ power regardless of the input line state. Once the
+ specified time has elapsed, output power will be
+ restored.
+
+ Setting this value to noPutUpsToSleep(1) has no
+ effect.
+
+ The value noPutUpsToSleep(1) will always be returned
+ when the variable is read."
+ ::= { upsAdvControl 3 }
+
+
+upsAdvControlSimulatePowerFail OBJECT-TYPE
+ SYNTAX INTEGER {
+ noSimulatePowerFailure(1),
+ simulatePowerFailure(2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Setting this variable to simulatePowerFailure(2) causes
+ the UPS switch to battery power.
+
+ Setting this value to noSimulatePowerFailure(1) has no
+ effect.
+
+ The value noSimulatePowerFailure(1) will always be returned
+ when the variable is read."
+ ::= { upsAdvControl 4 }
+
+
+upsAdvControlFlashAndBeep OBJECT-TYPE
+ SYNTAX INTEGER {
+ noFlashAndBeep(1),
+ flashAndBeep(2),
+ flashAndBeepSyncGroup(3)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Setting this variable to flashAndBeep(2) causes the
+ UPS to beep and simultaneously turn on the UPS front
+ panel lights (Smart-UPS only).
+
+ If this UPS is an active member of a Synchronized Control
+ Group (SCG), the flashAndBeepSyncGroup(3) command will
+ Flash and Beep all active Group members regardless of
+ current AC output status.
+
+ Setting this value to noFlashAndBeep(1) has no
+ effect.
+
+ The value noFlashAndBeep(1) will always be returned
+ when the variable is read."
+ ::= { upsAdvControl 5 }
+
+
+upsAdvControlTurnOnUPS OBJECT-TYPE
+ SYNTAX INTEGER {
+ noTurnOnUPS(1),
+ turnOnUPS(2),
+ turnOnUPSSyncGroup(3)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Setting this variable to turnOnUPS(2) causes the
+ UPS to be turned on immediately.
+
+ If this UPS is an active member of a Synchronized Control
+ Group (SCG), the turnOnUPSSyncGroup(3) command will perform
+ a Synchronized Turn On of all active Group members
+ regardless of their current AC output status.
+
+ Setting this value to noTurnOnUPS(1) has no
+ effect.
+
+ The value noTurnOnUPS(1) will always be returned
+ when the variable is read."
+ ::= { upsAdvControl 6 }
+
+upsAdvControlBypassSwitch OBJECT-TYPE
+ SYNTAX INTEGER {
+ noBypassSwitch (1),
+ switchToBypass (2),
+ switchOutOfBypass(3)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "This switch puts the UPS in or out of bypass mode."
+ ::= { upsAdvControl 7 }
+
+
+-- the upsTest group
+
+-- the upsBasicTest group
+
+-- the upsAdvTest group
+
+upsAdvTestDiagnosticSchedule OBJECT-TYPE
+ SYNTAX INTEGER {
+ unknown(1),
+ biweekly(2),
+ weekly(3),
+ atTurnOn(4),
+ never(5)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The UPS system's automatic battery test schedule."
+ ::= { upsAdvTest 1 }
+
+
+upsAdvTestDiagnostics OBJECT-TYPE
+ SYNTAX INTEGER {
+ noTestDiagnostics(1),
+ testDiagnostics(2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Setting this variable to testDiagnostics(2) causes
+ the UPS to perform a diagnostic self test.
+
+ Setting this value to noTestDiagnostics(1) has no
+ effect.
+
+ The value noTestDiagnostics(1) will always be returned
+ when the variable is read."
+ ::= { upsAdvTest 2 }
+
+upsAdvTestDiagnosticsResults OBJECT-TYPE
+ SYNTAX INTEGER {
+ ok(1),
+ failed(2),
+ invalidTest(3),
+ testInProgress(4)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The results of the last UPS diagnostics test performed."
+ ::= { upsAdvTest 3 }
+
+upsAdvTestLastDiagnosticsDate OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The date the last UPS diagnostics test was performed in
+ mm/dd/yy format."
+ ::= { upsAdvTest 4 }
+
+upsAdvTestRuntimeCalibration OBJECT-TYPE
+ SYNTAX INTEGER {
+ noPerformCalibration(1),
+ performCalibration(2),
+ cancelCurrentCalibration(3)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Setting this variable to performCalibration(2) causes
+ the UPS to discharge to calibrate the UPS.
+ The test will only start if the battery capacity is 100%.
+ The test runs until capacity is less than 25%.
+
+ Setting this variable to cancelCurrentCalibration(3)
+ after setting performCalibration(2) will cancel the
+ current discharge.
+
+ Setting this variable to noPerformCalibration(1)
+ will have no effect.
+
+ The value noPerformCalibration(1) will always be returned
+ when the variable is read.
+
+ The result of the calibration will be saved in
+ upsAdvTestCalibrationResult."
+ ::= { upsAdvTest 5 }
+
+upsAdvTestCalibrationResults OBJECT-TYPE
+ SYNTAX INTEGER {
+ ok(1),
+ invalidCalibration(2),
+ calibrationInProgress(3)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The results of the last runtime calibration.
+
+ Value ok(1) means a successful runtime calibration.
+
+ Value invalidCalibration(2) indicates last calibration did
+ not take place since the battery capacity was below
+ 100%.
+
+ Value calibrationInProgress(3) means a calibration
+ is occurring now. "
+ ::= { upsAdvTest 6 }
+
+upsAdvTestCalibrationDate OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The date the last UPS runtime calibration was
+ performed in mm/dd/yy format."
+ ::= { upsAdvTest 7 }
+
+-- the upsComm group
+
+upsCommStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ ok(1),
+ noComm(2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The status of agent's communication with UPS. "
+ ::= { upsComm 1 }
+
+
+-- the measureUps group
+-- the Environ group
+
+mUpsEnvironAmbientTemperature OBJECT-TYPE
+ SYNTAX Gauge
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The ambient temperature in Celsius for Probe 1."
+ ::= { mUpsEnviron 1 }
+
+mUpsEnvironRelativeHumidity OBJECT-TYPE
+ SYNTAX Gauge
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The relative humidity as a percentage for Probe 1."
+ ::= { mUpsEnviron 2 }
+
+
+mUpsEnvironAmbientTemperature2 OBJECT-TYPE
+ SYNTAX Gauge
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The ambient temperature in Celsius for Probe 2."
+ ::= { mUpsEnviron 3 }
+
+mUpsEnvironRelativeHumidity2 OBJECT-TYPE
+ SYNTAX Gauge
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The relative humidity as a percentage for Probe 2."
+ ::= { mUpsEnviron 4 }
+
+-- the mUpsContact group
+
+mUpsContactNumContacts OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of contacts supported by the Measure-UPS."
+ ::= { mUpsContact 1 }
+
+mUpsContactTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ContactEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A list of contacts supported by the Measure-UPS."
+ ::= { mUpsContact 2 }
+
+mUpsContactEntry OBJECT-TYPE
+ SYNTAX ContactEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A contact entry containing information for a given contact."
+ INDEX { contactNumber }
+ ::= { mUpsContactTable 1 }
+
+ContactEntry ::=
+ SEQUENCE {
+ contactNumber
+ INTEGER,
+ normalState
+ INTEGER,
+ description
+ DisplayString,
+ monitoringStatus
+ INTEGER,
+ currentStatus
+ INTEGER
+ }
+
+contactNumber OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "An index identifying the contact on the Measure-UPS."
+ ::= { mUpsContactEntry 1 }
+
+normalState OBJECT-TYPE
+ SYNTAX INTEGER {
+ unknown(1),
+ open(2),
+ closed(3)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The normal operating position of the contact. If the normal
+ operating position cannot be set then it is controlled via the
+ dip switch on the Measure-UPS and is therefore read-only."
+ ::= { mUpsContactEntry 2 }
+
+description OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The description of the purpose/use of the contact."
+ ::= { mUpsContactEntry 3 }
+
+monitoringStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ unknown(1),
+ enabled(2),
+ disabled(3)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "A flag indicating whether this contact is
+ monitored, or not."
+ ::= { mUpsContactEntry 4 }
+
+currentStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ unknown(1),
+ noFault(2),
+ fault(3)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This value indicates the current state of the contact.
+ If the contact is not in its normal state. This value
+ is set to fault(2)."
+ ::= { mUpsContactEntry 5 }
+
+-- Three Phase Group
+
+--
+-- Reset Max/Min Values Group
+--
+
+ upsPhaseResetMaxMinValues OBJECT-TYPE
+ SYNTAX INTEGER {
+ none (1),
+ reset (2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Reset the maximum and minimum UPS values:
+ upsPhaseInputMaxVoltage, upsPhaseInputMinVoltage,
+ upsPhaseInputMaxCurrent, upsPhaseInputMinCurrent,
+ upsPhaseInputMaxPower, upsPhaseInputMinPower,
+ upsPhaseOutputMaxCurrent, upsPhaseOutputMinCurrent,
+ upsPhaseOutputMaxLoad, upsPhaseOutputMinLoad,
+ upsPhaseOutputMaxPercentLoad, upsPhaseOutputMinPercentLoad,
+ upsPhaseOutputMaxPower, upsPhaseOutputMinPower,
+ upsPhaseOutputMaxPercentPower, upsPhaseOutputMinPercentPower."
+ ::= { upsPhaseResetValues 1 }
+
+--
+-- Input Group
+--
+
+-- Number of Inputs
+
+ upsPhaseNumInputs OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of input feeds to this device.
+ This variable indicates the number of rows in the
+ input table."
+ ::= { upsPhaseInput 1 }
+
+-- Input Table
+
+ upsPhaseInputTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF UpsPhaseInputEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A list of input table entries. The number of entries
+ is given by the value of upsPhaseNumInputs."
+ ::= { upsPhaseInput 2 }
+
+ upsPhaseInputEntry OBJECT-TYPE
+ SYNTAX UpsPhaseInputEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "An entry containing information applicable to a
+ particular input."
+ INDEX { upsPhaseInputTableIndex }
+ ::= { upsPhaseInputTable 1 }
+
+ UpsPhaseInputEntry ::= SEQUENCE {
+ upsPhaseInputTableIndex INTEGER,
+ upsPhaseNumInputPhases INTEGER,
+ upsPhaseInputVoltageOrientation INTEGER,
+ upsPhaseInputFrequency INTEGER,
+ upsPhaseInputType INTEGER,
+ upsPhaseInputName DisplayString
+ }
+
+ upsPhaseInputTableIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The input identifier."
+ ::= { upsPhaseInputEntry 1 }
+
+ upsPhaseNumInputPhases OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of input phases utilized in this
+ device. The sum of all the upsPhaseNumInputPhases
+ variable indicates the number of rows in the
+ input phase table."
+ ::= { upsPhaseInputEntry 2 }
+
+ upsPhaseInputVoltageOrientation OBJECT-TYPE
+ SYNTAX INTEGER {
+ unknown(1),
+ singlePhase(2),
+ splitPhase(3),
+ threePhasePhaseToNeutral(4),
+ threePhasePhaseToPhase(5)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The input voltage orientation:
+ 1: unknown for this UPS
+ 2: singlePhase - phase 1 voltage is between Phase 1
+ and Neutral.
+ 3: splitPhase - phase 1 voltage is between Phase 1 and
+ Neutral; phase 2 voltage is between Phase 2 and Neutral;
+ phase 3 voltage is between Phase 1 and Phase2.
+ 4: threePhasePhaseToNeutral - phase 1 voltage is between
+ Phase 1 and Neutral; phase 2 voltage is between Phase 2
+ and Neutral; phase 3 voltage is between Phase3 and
+ Neutral.
+ 5: threePhasePhaseToPhase - phase 1 voltage is between
+ Phase 1 and Phase 2; phase 2 voltage is between Phase 2
+ and Phase 3; phase 3 voltage is between Phase 3 and
+ Phase 1."
+ ::= { upsPhaseInputEntry 3 }
+
+ upsPhaseInputFrequency OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The input frequency in 0.1 Hertz, or -1 if it's unsupported
+ by this UPS."
+ ::= { upsPhaseInputEntry 4 }
+
+ upsPhaseInputType OBJECT-TYPE
+ SYNTAX INTEGER {
+ unknown(1),
+ main(2),
+ bypass(3)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The input type."
+ ::= { upsPhaseInputEntry 5 }
+
+ upsPhaseInputName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "A name given to a particular input."
+ ::= { upsPhaseInputEntry 6 }
+
+-- Input Phase Table
+
+ upsPhaseInputPhaseTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF UpsPhaseInputPhaseEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A list of input table entries. The number of entries
+ is given by the sum of the upsPhaseNumInputPhases."
+ ::= { upsPhaseInput 3 }
+
+ upsPhaseInputPhaseEntry OBJECT-TYPE
+ SYNTAX UpsPhaseInputPhaseEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "An entry containing information applicable to a
+ particular input phase."
+ INDEX { upsPhaseInputPhaseTableIndex, upsPhaseInputPhaseIndex }
+ ::= { upsPhaseInputPhaseTable 1 }
+
+ UpsPhaseInputPhaseEntry ::= SEQUENCE {
+ upsPhaseInputPhaseTableIndex INTEGER,
+ upsPhaseInputPhaseIndex INTEGER,
+ upsPhaseInputVoltage INTEGER,
+ upsPhaseInputMaxVoltage INTEGER,
+ upsPhaseInputMinVoltage INTEGER,
+ upsPhaseInputCurrent INTEGER,
+ upsPhaseInputMaxCurrent INTEGER,
+ upsPhaseInputMinCurrent INTEGER,
+ upsPhaseInputPower INTEGER,
+ upsPhaseInputMaxPower INTEGER,
+ upsPhaseInputMinPower INTEGER
+ }
+
+ upsPhaseInputPhaseTableIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The input identifier."
+ ::= { upsPhaseInputPhaseEntry 1 }
+
+ upsPhaseInputPhaseIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The input phase identifier."
+ ::= { upsPhaseInputPhaseEntry 2 }
+
+ upsPhaseInputVoltage OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The input voltage in VAC, or -1 if it's unsupported
+ by this UPS."
+ ::= { upsPhaseInputPhaseEntry 3 }
+
+ upsPhaseInputMaxVoltage OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The maximum input voltage in VAC measured
+ since the last reset (upsPhaseResetMaxMinValues), or
+ -1 if it's unsupported by this UPS.
+ Sampled every 30 seconds."
+ ::= { upsPhaseInputPhaseEntry 4 }
+
+ upsPhaseInputMinVoltage OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The minimum input voltage in VAC measured
+ since the last reset (upsPhaseResetMaxMinValues), or
+ -1 if it's unsupported by this UPS.
+ Sampled every 30 seconds."
+ ::= { upsPhaseInputPhaseEntry 5 }
+
+ upsPhaseInputCurrent OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The input current in 0.1 amperes, or -1 if it's
+ unsupported by this UPS."
+ ::= { upsPhaseInputPhaseEntry 6 }
+
+ upsPhaseInputMaxCurrent OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The maximum input current in 0.1 amperes measured
+ since the last reset (upsPhaseResetMaxMinValues), or
+ -1 if it's unsupported by this UPS.
+ Sampled every 30 seconds."
+ ::= { upsPhaseInputPhaseEntry 7 }
+
+ upsPhaseInputMinCurrent OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The minimum input current in 0.1 amperes measured
+ since the last reset (upsPhaseResetMaxMinValues), or
+ -1 if it's unsupported by this UPS.
+ Sampled every 30 seconds."
+ ::= { upsPhaseInputPhaseEntry 8 }
+
+ upsPhaseInputPower OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The input power in Watts, or -1 if it's unsupported
+ by this UPS."
+ ::= { upsPhaseInputPhaseEntry 9 }
+
+ upsPhaseInputMaxPower OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The maximum input power in Watts measured
+ since the last reset (upsPhaseResetMaxMinValues), or
+ -1 if it's unsupported by this UPS.
+ Sampled every 30 seconds."
+ ::= { upsPhaseInputPhaseEntry 10 }
+
+ upsPhaseInputMinPower OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The minimum input power in Watts measured
+ since the last reset (upsPhaseResetMaxMinValues), or
+ -1 if it's unsupported by this UPS.
+ Sampled every 30 seconds."
+ ::= { upsPhaseInputPhaseEntry 11 }
+
+ --
+ -- The Output group.
+ --
+
+ -- Number of Outputs
+
+ upsPhaseNumOutputs OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of output feeds to this device.
+ This variable indicates the number of rows in the
+ output table."
+ ::= { upsPhaseOutput 1 }
+
+ -- Output Table
+
+ upsPhaseOutputTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF UpsPhaseOutputEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A list of output table entries. The number of entries
+ is given by the value of upsOutputNumPhases."
+ ::= { upsPhaseOutput 2 }
+
+ upsPhaseOutputEntry OBJECT-TYPE
+ SYNTAX UpsPhaseOutputEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "An entry containing information applicable to a
+ particular output."
+ INDEX { upsPhaseOutputTableIndex }
+ ::= { upsPhaseOutputTable 1 }
+
+ UpsPhaseOutputEntry ::= SEQUENCE {
+ upsPhaseOutputTableIndex INTEGER,
+ upsPhaseNumOutputPhases INTEGER,
+ upsPhaseOutputVoltageOrientation INTEGER,
+ upsPhaseOutputFrequency INTEGER
+ }
+
+ upsPhaseOutputTableIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The output identifier."
+ ::= { upsPhaseOutputEntry 1 }
+
+ upsPhaseNumOutputPhases OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of output phases utilized in this
+ device. The sum of all the upsPhaseNumOutputPhases
+ variable indicates the number of rows in the
+ output phase table."
+ ::= { upsPhaseOutputEntry 2 }
+
+ upsPhaseOutputVoltageOrientation OBJECT-TYPE
+ SYNTAX INTEGER {
+ unknown(1),
+ singlePhase(2),
+ splitPhase(3),
+ threePhasePhaseToNeutral(4),
+ threePhasePhaseToPhase(5)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The output voltage orientation:
+ 1: unknown for this UPS
+ 2: singlePhase - phase 1 voltage is between Phase 1
+ and Neutral.
+ 3: splitPhase - phase 1 voltage is between Phase 1 and
+ Neutral; phase 2 voltage is between Phase 2 and Neutral;
+ phase 3 voltage is between Phase 1 and Phase2.
+ 4: threePhasePhaseToNeutral - phase 1 voltage is between
+ Phase 1 and Neutral; phase 2 voltage is between Phase 2
+ and Neutral; phase 3 voltage is between Phase3 and
+ Neutral.
+ 5: threePhasePhaseToPhase - phase 1 voltage is between
+ Phase 1 and Phase 2; phase 2 voltage is between Phase 2
+ and Phase 3; phase 3 voltage is between Phase 3 and
+ Phase 1."
+ ::= { upsPhaseOutputEntry 3 }
+
+ upsPhaseOutputFrequency OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The output frequency in 0.1 Hertz, or -1 if it's
+ unsupported by this UPS."
+ ::= { upsPhaseOutputEntry 4 }
+
+ -- Output Phase Table
+
+ upsPhaseOutputPhaseTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF UpsPhaseOutputPhaseEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A list of output table entries. The number of
+ entries is given by the sum of the upsPhaseNumOutputPhases."
+ ::= { upsPhaseOutput 3 }
+
+ upsPhaseOutputPhaseEntry OBJECT-TYPE
+ SYNTAX UpsPhaseOutputPhaseEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "An entry containing information applicable to a
+ particular output phase."
+ INDEX { upsPhaseOutputPhaseTableIndex, upsPhaseOutputPhaseIndex }
+ ::= { upsPhaseOutputPhaseTable 1 }
+
+ UpsPhaseOutputPhaseEntry ::= SEQUENCE {
+ upsPhaseOutputPhaseTableIndex INTEGER,
+ upsPhaseOutputPhaseIndex INTEGER,
+ upsPhaseOutputVoltage INTEGER,
+ upsPhaseOutputCurrent INTEGER,
+ upsPhaseOutputMaxCurrent INTEGER,
+ upsPhaseOutputMinCurrent INTEGER,
+ upsPhaseOutputLoad INTEGER,
+ upsPhaseOutputMaxLoad INTEGER,
+ upsPhaseOutputMinLoad INTEGER,
+ upsPhaseOutputPercentLoad INTEGER,
+ upsPhaseOutputMaxPercentLoad INTEGER,
+ upsPhaseOutputMinPercentLoad INTEGER,
+ upsPhaseOutputPower INTEGER,
+ upsPhaseOutputMaxPower INTEGER,
+ upsPhaseOutputMinPower INTEGER,
+ upsPhaseOutputPercentPower INTEGER,
+ upsPhaseOutputMaxPercentPower INTEGER,
+ upsPhaseOutputMinPercentPower INTEGER
+ }
+
+ upsPhaseOutputPhaseTableIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The output identifier."
+ ::= { upsPhaseOutputPhaseEntry 1 }
+
+ upsPhaseOutputPhaseIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The output phase identifier."
+ ::= { upsPhaseOutputPhaseEntry 2 }
+
+ upsPhaseOutputVoltage OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The output voltage in VAC, or -1 if it's unsupported
+ by this UPS."
+ ::= { upsPhaseOutputPhaseEntry 3 }
+
+ upsPhaseOutputCurrent OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The output current in 0.1 amperes drawn
+ by the load on the UPS, or -1 if it's unsupported
+ by this UPS."
+ ::= { upsPhaseOutputPhaseEntry 4 }
+
+ upsPhaseOutputMaxCurrent OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The maximum output current in 0.1 amperes measured
+ since the last reset (upsPhaseResetMaxMinValues), or
+ -1 if it's unsupported by this UPS.
+ Sampled every 30 seconds."
+ ::= { upsPhaseOutputPhaseEntry 5 }
+
+ upsPhaseOutputMinCurrent OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The minimum output current in 0.1 amperes measured
+ since the last reset (upsPhaseResetMaxMinValues), or
+ -1 if it's unsupported by this UPS.
+ Sampled every 30 seconds."
+ ::= { upsPhaseOutputPhaseEntry 6 }
+
+ upsPhaseOutputLoad OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The output load in VA, or -1 if it's unsupported
+ by this UPS."
+ ::= { upsPhaseOutputPhaseEntry 7 }
+
+ upsPhaseOutputMaxLoad OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The maximum output load in VA measured
+ since the last reset (upsPhaseResetMaxMinValues), or
+ -1 if it's unsupported by this UPS.
+ Sampled every 30 seconds."
+ ::= { upsPhaseOutputPhaseEntry 8 }
+
+ upsPhaseOutputMinLoad OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The minimum output load in VA measured
+ since the last reset (upsPhaseResetMaxMinValues), or
+ -1 if it's unsupported by this UPS.
+ Sampled every 30 seconds."
+ ::= { upsPhaseOutputPhaseEntry 9 }
+
+ upsPhaseOutputPercentLoad OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The percentage of the UPS load capacity in VA at
+ redundancy @ (n + x) presently being used on this
+ output phase, or -1 if it's unsupported by this UPS."
+ ::= { upsPhaseOutputPhaseEntry 10 }
+
+ upsPhaseOutputMaxPercentLoad OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The maximum percentage of the UPS load capacity in
+ VA measured at redundancy @ (n + x) presently
+ being used on this output phase since the last reset
+ (upsPhaseResetMaxMinValues), or -1 if it's unsupported
+ by this UPS. Sampled every 30 seconds."
+ ::= { upsPhaseOutputPhaseEntry 11 }
+
+ upsPhaseOutputMinPercentLoad OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The minimum percentage of the UPS load capacity in
+ VA measured at redundancy @ (n + x) presently
+ being used on this output phase since the last reset
+ (upsPhaseResetMaxMinValues), or -1 if it's unsupported
+ by this UPS. Sampled every 30 seconds."
+ ::= { upsPhaseOutputPhaseEntry 12 }
+
+ upsPhaseOutputPower OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The output power in Watts, or -1 if it's
+ unsupported by this UPS."
+ ::= { upsPhaseOutputPhaseEntry 13 }
+
+ upsPhaseOutputMaxPower OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The maximum output power in Watts measured
+ since the last reset (upsPhaseResetMaxMinValues), or
+ -1 if it's unsupported by this UPS.
+ Sampled every 30 seconds."
+ ::= { upsPhaseOutputPhaseEntry 14 }
+
+ upsPhaseOutputMinPower OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The minimum output power in Watts measured
+ since the last reset (upsPhaseResetMaxMinValues), or
+ -1 if it's unsupported by this UPS.
+ Sampled every 30 seconds."
+ ::= { upsPhaseOutputPhaseEntry 15 }
+
+ upsPhaseOutputPercentPower OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The percentage of the UPS power capacity in Watts at
+ redundancy @ (n + x) presently being used on this
+ output phase, or -1 if it's unsupported by this UPS."
+ ::= { upsPhaseOutputPhaseEntry 16 }
+
+ upsPhaseOutputMaxPercentPower OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The maximum percentage of the UPS power capacity
+ in Watts measured at redundancy @ (n + x) presently
+ being used on this output phase since the last
+ reset (upsPhaseResetMaxMinValues), or -1 if it's
+ unsupported by this UPS. Sampled every 30 seconds."
+ ::= { upsPhaseOutputPhaseEntry 17 }
+
+ upsPhaseOutputMinPercentPower OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The maximum percentage of the UPS power capacity
+ in Watts measured at redundancy @ (n + x) presently
+ being used on this output phase since the last
+ reset (upsPhaseResetMaxMinValues), or -1 if it's
+ unsupported by this UPS. Sampled every 30 seconds."
+ ::= { upsPhaseOutputPhaseEntry 18 }
+
+-- the upsOutletGroupStatus group
+
+upsOutletGroupStatusTableSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of outlet groups for the UPS."
+ ::= { upsOutletGroupStatus 1 }
+
+upsOutletGroupStatusTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF UpsOutletGroupStatusEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for getting status of the outlet groups. The number of
+ entries is contained in the upsOutletGroupStatusTableSize OID."
+ ::= { upsOutletGroupStatus 2 }
+
+upsOutletGroupStatusEntry OBJECT-TYPE
+ SYNTAX UpsOutletGroupStatusEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The outlet group status to get."
+ INDEX { upsOutletGroupStatusIndex}
+ ::= { upsOutletGroupStatusTable 1 }
+
+UpsOutletGroupStatusEntry ::=
+ SEQUENCE {
+ upsOutletGroupStatusIndex INTEGER,
+ upsOutletGroupStatusName DisplayString,
+ upsOutletGroupStatusGroupState INTEGER,
+ upsOutletGroupStatusCommandPending INTEGER
+ }
+
+upsOutletGroupStatusIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the outlet group entry."
+ ::= { upsOutletGroupStatusEntry 1 }
+
+upsOutletGroupStatusName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The name of the outlet group. This OID is provided
+ for informational purposes only. This value is set
+ by the upsOutletGroupConfigName OID."
+ ::= { upsOutletGroupStatusEntry 2 }
+
+upsOutletGroupStatusGroupState OBJECT-TYPE
+ SYNTAX INTEGER {
+ upsOutletGroupStatusOn (1),
+ upsOutletGroupStatusOff (2),
+ upsOutletGroupStatusUnknown (3)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this variable will return the outlet group state. If the outlet
+ group is on, the upsOutletGroupStatusOn (1) value will be returned. If
+ the outlet group is off, the upsOutletGroupStatusOff (2) value will be
+ returned. If the state of the outlet group cannot be determined, the
+ upsOutletGroupStatusUnknown (3) value will be returned."
+
+ ::= { upsOutletGroupStatusEntry 3 }
+
+upsOutletGroupStatusCommandPending OBJECT-TYPE
+ SYNTAX INTEGER {
+ upsOutletGroupCommandPending (1),
+ upsOutletGroupNoCommandPending (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this variable will return the command pending
+ state of the outlet group. If a command is pending on the
+ outlet group, the upsOutletGroupCommandPending (1) value
+ will be returned. If there is not a command pending
+ on the outlet group, the upsOutletGroupNoCommandPending (2)
+ will be returned."
+ ::= { upsOutletGroupStatusEntry 4 }
+
+-- the upsOutletGroupConfig group
+
+upsOutletGroupConfigTableSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of outlet groups for the UPS."
+ ::= { upsOutletGroupConfig 1 }
+
+upsOutletGroupConfigTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF UpsOutletGroupConfigEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The list of outlet groups to configure. The number of entries
+ is defined by the upsOutletGroupConfigTableSize OID."
+ ::= { upsOutletGroupConfig 2 }
+
+upsOutletGroupConfigEntry OBJECT-TYPE
+ SYNTAX UpsOutletGroupConfigEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The outlet groups to configure."
+ INDEX { upsOutletGroupConfigIndex}
+ ::= { upsOutletGroupConfigTable 1 }
+
+UpsOutletGroupConfigEntry ::=
+ SEQUENCE {
+ upsOutletGroupConfigIndex INTEGER,
+ upsOutletGroupConfigName DisplayString,
+ upsOutletGroupConfigPowerOnDelay INTEGER,
+ upsOutletGroupConfigPowerOffDelay INTEGER,
+ upsOutletGroupConfigRebootDuration INTEGER
+ }
+
+upsOutletGroupConfigIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the outlet group entry."
+ ::= { upsOutletGroupConfigEntry 1 }
+
+upsOutletGroupConfigName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The name of the outlet group."
+ ::= { upsOutletGroupConfigEntry 2 }
+
+upsOutletGroupConfigPowerOnDelay OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The amount of time (in seconds) the outlet group will delay
+ powering on when the delayed on or reboot command is applied.
+ Allowed values are -1 (for Never) or 0 to 600 seconds."
+ ::= { upsOutletGroupConfigEntry 3 }
+
+upsOutletGroupConfigPowerOffDelay OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The amount of time (in seconds) the outlet group will delay
+ powering off when the delayed off command is applied.
+ Allowed values are 0 to 600 seconds."
+ ::= { upsOutletGroupConfigEntry 4 }
+
+upsOutletGroupConfigRebootDuration OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "During a reboot sequence, power is turned off and then
+ back on. This OID defines the amount of time to wait,
+ in seconds, after turning the power off, at the start
+ of the sequence, before initiating the power on sequence.
+ Allowed values are 0 to 600 seconds."
+ ::= { upsOutletGroupConfigEntry 5 }
+
+-- the upsOutletGroupControl group
+
+upsOutletGroupControlTableSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of outlet groups for the UPS."
+ ::= { upsOutletGroupControl 1 }
+
+upsOutletGroupControlTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF UpsOutletGroupControlEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for control of individual outlet groups. The number of
+ entries is contained in the upsOutletGroupControlTableSize OID."
+ ::= { upsOutletGroupControl 2 }
+
+upsOutletGroupControlEntry OBJECT-TYPE
+ SYNTAX UpsOutletGroupControlEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The outlet group to control."
+ INDEX { upsOutletGroupControlIndex}
+ ::= { upsOutletGroupControlTable 1 }
+
+UpsOutletGroupControlEntry ::=
+ SEQUENCE {
+ upsOutletGroupControlIndex INTEGER,
+ upsOutletGroupControlName DisplayString,
+ upsOutletGroupControlCommand INTEGER
+ }
+
+upsOutletGroupControlIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the outlet group entry."
+ ::= { upsOutletGroupControlEntry 1 }
+
+upsOutletGroupControlName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The name of the outlet group. This OID is provided
+ for informational purposes only. This value is set
+ by the upsOutletGroupConfigName OID."
+ ::= { upsOutletGroupControlEntry 2 }
+
+upsOutletGroupControlCommand OBJECT-TYPE
+ SYNTAX INTEGER {
+ upsOutletGroupImmediateOn (1),
+ upsOutletGroupImmediateOff (2),
+ upsOutletGroupImmediateReboot (3),
+ upsOutletGroupDelayedOn (4),
+ upsOutletGroupDelayedOff (5),
+ upsOutletGroupDelayedReboot (6),
+ upsOutletGroupCancelPendingCommand (7),
+ upsOutletGroupControlUnknown (8)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this variable will return the outlet group state. If the outlet
+ group is on, the upsOutletGroupImmediateOn (1) value will be returned. If
+ the outlet group is off, the upsOutletGroupImmediateOff (2) value will be
+ returned.
+
+ If the state of the outlet group cannot be determined, the
+ upsOutletGroupControlUnknown (8) value will be returned.
+
+ Setting this variable to upsOutletGroupImmediateOn (1) will turn the
+ outlet group on.
+
+ Setting this variable to upsOutletGroupImmediateOff (2) will turn the
+ outlet group off.
+
+ Setting this variable to upsOutletGroupImmediateReboot (3) will turn the outlet
+ group off, wait the upsOutletGroupConfigRebootDuration OID time, wait the
+ upsOutletGroupConfigPowerOnDelay OID, and then turn the outlet group on.
+
+ Setting this variable to upsOutletGroupDelayedOn (4) will turn the outlet
+ group on after the upsOutletGroupConfigPowerOnDelay OID has elapsed.
+
+ Setting this variable to upsOutletGroupDelayedOff (5) will turn the outlet
+ group off after the upsOutletGroupConfigPowerOffDelay OID has elapsed.
+
+ Setting this variable to upsOutletGroupDelayedReboot (6) will turn the outlet
+ group off after the upsOutletGroupConfigPowerOffDelay OID has elapsed, wait the
+ upsOutletGroupConfigRebootDuration OID time, wait the
+ upsOutletGroupConfigPowerOnDelay OID, and then turn the outlet group on.
+
+ Setting this variable to upsOutletGroupCancelPendingCommand (7) will
+ cause any pending command to this outlet group to be canceled."
+ ::= { upsOutletGroupControlEntry 3 }
+
+-- the upsDiagnosticIM group
+
+upsDiagIMTableSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of Intelligence Modules in or attached to the UPS."
+ ::= { upsDiagnosticIM 1 }
+
+upsDiagIMTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF UpsDiagIMEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for diagnostics of individual Intelligence Modules. The number of
+ entries is contained in the upsDiagIMTableSize OID."
+ ::= { upsDiagnosticIM 2 }
+
+upsDiagIMEntry OBJECT-TYPE
+ SYNTAX UpsDiagIMEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The diagnostics and information of an Intelligence Module."
+ INDEX { upsDiagIMIndex}
+ ::= { upsDiagIMTable 1 }
+
+UpsDiagIMEntry ::=
+ SEQUENCE {
+ upsDiagIMIndex INTEGER,
+ upsDiagIMType INTEGER,
+ upsDiagIMStatus INTEGER,
+ upsDiagIMFirmwareRev DisplayString,
+ upsDiagIMSlaveFirmwareRev DisplayString,
+ upsDiagIMHardwareRev DisplayString,
+ upsDiagIMSerialNum DisplayString,
+ upsDiagIMManufactureDate DisplayString
+ }
+
+upsDiagIMIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the Intelligence Module entry."
+ ::= { upsDiagIMEntry 1 }
+
+upsDiagIMType OBJECT-TYPE
+ SYNTAX INTEGER {
+ imUnknown (1),
+ imMIM (2),
+ imRIM (3)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The type of the Intelligence Module.
+ imUnknown(1) indicates the IM type is unknown.
+ imMIM(2) indicates the IM type is a Main Intelligence Module.
+ imRIM(3) indicates the IM type is Redundant Intelligence Module."
+ ::= { upsDiagIMEntry 2 }
+
+upsDiagIMStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ unknown (1),
+ notInstalled (2),
+ offOk (3),
+ onOk (4),
+ offFail (5),
+ onFail (6),
+ lostComm (7)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The status of the Intelligence Module.
+ unknown(1) indicates the device status is unknown.
+ notInstalled(2) indicates the device is not installed.
+ offOk(3) indicates the device status is off and OK.
+ onOk(4) indicates the device status is on and OK.
+ offFail(5) indicates the device status is off and failed.
+ onFail(6) indicates the device status is on and failed.
+ lostComm(7) indicates the device has lost communication."
+ ::= { upsDiagIMEntry 3 }
+
+upsDiagIMFirmwareRev OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The firmware revision of the Intelligence Module."
+ ::= { upsDiagIMEntry 4 }
+
+upsDiagIMSlaveFirmwareRev OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The slave firmware revision of the Intelligence Module."
+ ::= { upsDiagIMEntry 5 }
+
+upsDiagIMHardwareRev OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The hardware revision of the Intelligence Module."
+ ::= { upsDiagIMEntry 6 }
+
+upsDiagIMSerialNum OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The serial number of the Intelligence Module."
+ ::= { upsDiagIMEntry 7 }
+
+upsDiagIMManufactureDate OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The manufacture date of the Intelligence Module."
+ ::= { upsDiagIMEntry 8 }
+
+-- the upsDiagnosticPowerModules group
+
+upsDiagPMTableSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of Power Modules in or attached to the UPS."
+ ::= { upsDiagnosticPowerModules 1 }
+
+upsDiagPMTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF UpsDiagPMEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for diagnostics of Individual Power modules. The number of
+ entries is contained in the upsDiagPMTableSize OID."
+ ::= { upsDiagnosticPowerModules 2 }
+
+upsDiagPMEntry OBJECT-TYPE
+ SYNTAX UpsDiagPMEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The diagnostics of an Power Module."
+ INDEX { upsDiagPMIndex}
+ ::= { upsDiagPMTable 1 }
+
+UpsDiagPMEntry ::=
+ SEQUENCE {
+ upsDiagPMIndex INTEGER,
+ upsDiagPMStatus INTEGER,
+ upsDiagPMFirmwareRev DisplayString,
+ upsDiagPMHardwareRev DisplayString,
+ upsDiagPMSerialNum DisplayString,
+ upsDiagPMManufactureDate DisplayString
+ }
+
+upsDiagPMIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the Power Module entry."
+ ::= { upsDiagPMEntry 1 }
+
+upsDiagPMStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ unknown (1),
+ notInstalled (2),
+ offOk (3),
+ onOk (4),
+ offFail (5),
+ onFail (6),
+ lostComm (7)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The status of the Power Module.
+ unknown(1) indicates the device status is unknown.
+ notInstalled(2) indicates the device is not installed.
+ offOk(3) indicates the device status is off and OK.
+ onOk(4) indicates the device status is on and OK.
+ offFail(5) indicates the device status is off and failed.
+ onFail(6) indicates the device status is on and failed.
+ lostComm(7) indicates the device has lost communication."
+ ::= { upsDiagPMEntry 2 }
+
+upsDiagPMFirmwareRev OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The firmware revision of the Power Module."
+ ::= { upsDiagPMEntry 3 }
+
+upsDiagPMHardwareRev OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The hardware revision of the Power Module."
+ ::= { upsDiagPMEntry 4 }
+
+upsDiagPMSerialNum OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The serial number of the Power Module."
+ ::= { upsDiagPMEntry 5 }
+
+upsDiagPMManufactureDate OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The manufacture date of the Power Module."
+ ::= { upsDiagPMEntry 6 }
+
+-- the upsDiagnosticBatteries group
+
+upsDiagBatteryTableSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of batteries in or attached to the UPS."
+ ::= { upsDiagnosticBatteries 1 }
+
+upsDiagBatteryTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF UpsDiagBatteryEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for diagnostics of individual batteries. The number of
+ entries is contained in the upsDiagBattTableSize OID."
+ ::= { upsDiagnosticBatteries 2 }
+
+upsDiagBatteryEntry OBJECT-TYPE
+ SYNTAX UpsDiagBatteryEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The diagnostics of a battery."
+ INDEX { upsDiagBatteryIndex}
+ ::= { upsDiagBatteryTable 1 }
+
+UpsDiagBatteryEntry ::=
+ SEQUENCE {
+ upsDiagBatteryFrameIndex INTEGER,
+ upsDiagBatteryIndex INTEGER,
+ upsDiagBatteryStatus INTEGER,
+ upsDiagBatterySerialNumber DisplayString,
+ upsDiagBatteryFirmwareRev DisplayString,
+ upsDiagBatteryManufactureDate DisplayString,
+ upsDiagBatteryType DisplayString
+ }
+
+upsDiagBatteryFrameIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the battery frame entry.
+ Frame 0 indicates the Main frame. Extended Run (XR) frames
+ start from index 1."
+ ::= { upsDiagBatteryEntry 1 }
+
+upsDiagBatteryIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the battery entry."
+ ::= { upsDiagBatteryEntry 2 }
+
+upsDiagBatteryStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ unknown (1),
+ notInstalled (2),
+ ok (3),
+ failed (4),
+ highTemperature (5),
+ replaceImmediately (6),
+ lowCapacity (7)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The status of the battery.
+ unknown(1) indicates the device status is unknown.
+ notInstalled(2) indicates the device is not installed.
+ ok(3) indicates the battery status is OK.
+ failed(4) indicates the battery status is failed.
+ highTemperature(5) indicates the battery has a high temperature condition.
+ replaceImmediately(6) indicates the battery must be replaced immediately.
+ lowCapacity(7) indicates the battery has a low capacity."
+ ::= { upsDiagBatteryEntry 3 }
+
+upsDiagBatterySerialNumber OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The serial number of the battery."
+ ::= { upsDiagBatteryEntry 4 }
+
+upsDiagBatteryFirmwareRev OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The firmware revision of the battery."
+ ::= { upsDiagBatteryEntry 5 }
+
+upsDiagBatteryManufactureDate OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The manufacture date of the battery."
+ ::= { upsDiagBatteryEntry 6 }
+
+upsDiagBatteryType OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The battery type or rating for the battery."
+ ::= { upsDiagBatteryEntry 7 }
+
+-- the upsDiagnosticSubsystem group
+
+upsDiagSubSysFrameTableSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of frames attached to the UPS including the Main frame."
+ ::= { upsDiagnosticSubsystem 1 }
+
+upsDiagSubSysFrameTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF UpsDiagSubSysFrameEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for diagnostics of individual XR Frames."
+ ::= { upsDiagnosticSubsystem 2 }
+
+upsDiagSubSysFrameEntry OBJECT-TYPE
+ SYNTAX UpsDiagSubSysFrameEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The diagnostics of an XR Frame."
+ INDEX { upsDiagSubSysFrameIndex}
+ ::= { upsDiagSubSysFrameTable 1 }
+
+UpsDiagSubSysFrameEntry ::=
+ SEQUENCE {
+ upsDiagSubSysFrameIndex INTEGER,
+ upsDiagSubSysFrameType INTEGER,
+ upsDiagSubSysFrameFirmwareRev DisplayString,
+ upsDiagSubSysFrameHardwareRev DisplayString,
+ upsDiagSubSysFrameSerialNum DisplayString,
+ upsDiagSubSysFrameManufactureDate DisplayString
+ }
+
+upsDiagSubSysFrameIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The frame index entry."
+ ::= { upsDiagSubSysFrameEntry 1 }
+
+upsDiagSubSysFrameType OBJECT-TYPE
+ SYNTAX INTEGER {
+ unknown (1),
+ notInstalled (2),
+ frameTypeMain (3),
+ frameTypeXR (4),
+ frameTypeLXR (5)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The type of Frame.
+ unknown(1) indicates the device status is unknown.
+ notInstalled(2) indicates the device is not installed.
+ frameTypeMain(3) indicates the the frame type is the Main Frame.
+ frameTypeXR(4) indicates the frame type is an XR Frame.
+ frameTypeLXR(5) indicates the frame type is an LXR Frame."
+ ::= { upsDiagSubSysFrameEntry 2 }
+
+upsDiagSubSysFrameFirmwareRev OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The firmware revision of the frame."
+ ::= { upsDiagSubSysFrameEntry 3 }
+
+upsDiagSubSysFrameHardwareRev OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The hardware revision of the frame."
+ ::= { upsDiagSubSysFrameEntry 4 }
+
+upsDiagSubSysFrameSerialNum OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The serial number of the frame."
+ ::= { upsDiagSubSysFrameEntry 5 }
+
+upsDiagSubSysFrameManufactureDate OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The manufacture date of the frame."
+ ::= { upsDiagSubSysFrameEntry 6 }
+
+upsDiagSubSysIntBypSwitchTableSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of Internal Bypass switches attached to the UPS."
+ ::= { upsDiagnosticSubsystem 3 }
+
+upsDiagSubSysIntBypSwitchTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF UpsDiagSubSysIntBypSwitchEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for diagnostics of the Internal Bypass Switch."
+ ::= { upsDiagnosticSubsystem 4 }
+
+upsDiagSubSysIntBypSwitchEntry OBJECT-TYPE
+ SYNTAX UpsDiagSubSysIntBypSwitchEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The diagnostics of the Internal Bypass Switch."
+ INDEX { upsDiagSubSysIntBypSwitchIndex}
+ ::= { upsDiagSubSysIntBypSwitchTable 1 }
+
+UpsDiagSubSysIntBypSwitchEntry ::=
+ SEQUENCE {
+ upsDiagSubSysIntBypSwitchFrameIndex INTEGER,
+ upsDiagSubSysIntBypSwitchIndex INTEGER,
+ upsDiagSubSysIntBypSwitchStatus INTEGER,
+ upsDiagSubSysIntBypSwitchFirmwareRev DisplayString,
+ upsDiagSubSysIntBypSwitchHardwareRev DisplayString,
+ upsDiagSubSysIntBypSwitchSerialNum DisplayString,
+ upsDiagSubSysIntBypSwitchManufactureDate DisplayString
+ }
+
+upsDiagSubSysIntBypSwitchFrameIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The frame index entry."
+ ::= { upsDiagSubSysIntBypSwitchEntry 1 }
+
+upsDiagSubSysIntBypSwitchIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The Internal Bypass Switch index entry."
+ ::= { upsDiagSubSysIntBypSwitchEntry 2 }
+
+upsDiagSubSysIntBypSwitchStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ unknown (1),
+ notInstalled (2),
+ offOk (3),
+ onOk (4),
+ offFail (5),
+ onFail (6),
+ lostComm (7)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The Internal Bypass Switch status.
+ unknown(1) indicates the device status is unknown.
+ notInstalled(2) indicates the device is not installed.
+ offOk(3) indicates the device status is off and OK.
+ onOk(4) indicates the device status is on and OK.
+ offFail(5) indicates the device status is off and failed.
+ onFail(6) indicates the device status is on and failed.
+ lostComm(7) indicates the device has lost communication."
+ ::= { upsDiagSubSysIntBypSwitchEntry 3 }
+
+upsDiagSubSysIntBypSwitchFirmwareRev OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The firmware revision of the Internal Bypass Switch."
+ ::= { upsDiagSubSysIntBypSwitchEntry 4 }
+
+upsDiagSubSysIntBypSwitchHardwareRev OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The hardware revision of the Internal Bypass Switch."
+ ::= { upsDiagSubSysIntBypSwitchEntry 5 }
+
+upsDiagSubSysIntBypSwitchSerialNum OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The serial number of the Internal Bypass Switch."
+ ::= { upsDiagSubSysIntBypSwitchEntry 6 }
+
+upsDiagSubSysIntBypSwitchManufactureDate OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The manufacture date of the Internal Bypass Switch."
+ ::= { upsDiagSubSysIntBypSwitchEntry 7 }
+
+upsDiagSubSysBattMonitorTableSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of Battery Monitor Boards attached to the UPS."
+ ::= { upsDiagnosticSubsystem 5 }
+
+upsDiagSubSysBattMonitorTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF UpsDiagSubSysBattMonitorEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for diagnostics of the Battery Monitor Board."
+ ::= { upsDiagnosticSubsystem 6 }
+
+upsDiagSubSysBattMonitorEntry OBJECT-TYPE
+ SYNTAX UpsDiagSubSysBattMonitorEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The diagnostics of the Battery Monitor Board."
+ INDEX { upsDiagSubSysBattMonitorIndex}
+ ::= { upsDiagSubSysBattMonitorTable 1 }
+
+UpsDiagSubSysBattMonitorEntry ::=
+ SEQUENCE {
+ upsDiagSubSysBattMonitorFrameIndex INTEGER,
+ upsDiagSubSysBattMonitorIndex INTEGER,
+ upsDiagSubSysBattMonitorStatus INTEGER,
+ upsDiagSubSysBattMonitorFirmwareRev DisplayString,
+ upsDiagSubSysBattMonitorHardwareRev DisplayString,
+ upsDiagSubSysBattMonitorSerialNum DisplayString,
+ upsDiagSubSysBattMonitorManufactureDate DisplayString
+ }
+
+upsDiagSubSysBattMonitorFrameIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The frame index entry."
+ ::= { upsDiagSubSysBattMonitorEntry 1 }
+
+upsDiagSubSysBattMonitorIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index of the Battery Monitor Board."
+ ::= { upsDiagSubSysBattMonitorEntry 2 }
+
+upsDiagSubSysBattMonitorStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ unknown (1),
+ notInstalled (2),
+ offOk (3),
+ onOk (4),
+ offFail (5),
+ onFail (6),
+ lostComm (7)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The status of the Battery Monitor Board.
+ unknown(1) indicates the device status is unknown.
+ notInstalled(2) indicates the device is not installed.
+ offOk(3) indicates the device status is off and OK.
+ onOk(4) indicates the device status is on and OK.
+ offFail(5) indicates the device status is off and failed.
+ onFail(6) indicates the device status is on and failed.
+ lostComm(7) indicates the device has lost communication."
+ ::= { upsDiagSubSysBattMonitorEntry 3 }
+
+upsDiagSubSysBattMonitorFirmwareRev OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The firmware revision of the Battery Monitor Board."
+ ::= { upsDiagSubSysBattMonitorEntry 4 }
+
+upsDiagSubSysBattMonitorHardwareRev OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The hardware revision of the Battery Monitor Board."
+ ::= { upsDiagSubSysBattMonitorEntry 5 }
+
+upsDiagSubSysBattMonitorSerialNum OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The serial number of the Battery Monitor Board."
+ ::= { upsDiagSubSysBattMonitorEntry 6 }
+
+upsDiagSubSysBattMonitorManufactureDate OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The date of the manufacture for the Battery Monitor Board."
+ ::= { upsDiagSubSysBattMonitorEntry 7 }
+
+upsDiagSubSysExternalSwitchGearTableSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of External Switch Gears attached to the UPS."
+ ::= { upsDiagnosticSubsystem 7 }
+
+upsDiagSubSysExternalSwitchGearTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF UpsDiagSubSysExternalSwitchGearEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for diagnostics of the individual External Switch Gear."
+ ::= { upsDiagnosticSubsystem 8 }
+
+upsDiagSubSysExternalSwitchGearEntry OBJECT-TYPE
+ SYNTAX UpsDiagSubSysExternalSwitchGearEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The diagnostics of an individual External Switch Gear."
+ INDEX { upsDiagSubSysExternalSwitchGearIndex}
+ ::= { upsDiagSubSysExternalSwitchGearTable 1 }
+
+UpsDiagSubSysExternalSwitchGearEntry ::=
+ SEQUENCE {
+ upsDiagSubSysExternalSwitchGearFrameIndex INTEGER,
+ upsDiagSubSysExternalSwitchGearIndex INTEGER,
+ upsDiagSubSysExternalSwitchGearStatus INTEGER,
+ upsDiagSubSysExternalSwitchGearFirmwareRev DisplayString,
+ upsDiagSubSysExternalSwitchGearHardwareRev DisplayString,
+ upsDiagSubSysExternalSwitchGearSerialNum DisplayString,
+ upsDiagSubSysExternalSwitchGearManufactureDate DisplayString
+ }
+
+upsDiagSubSysExternalSwitchGearFrameIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The frame index entry."
+ ::= { upsDiagSubSysExternalSwitchGearEntry 1 }
+
+upsDiagSubSysExternalSwitchGearIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index of the External Switch Gear."
+ ::= { upsDiagSubSysExternalSwitchGearEntry 2 }
+
+upsDiagSubSysExternalSwitchGearStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ unknown (1),
+ notInstalled (2),
+ offOk (3),
+ onOk (4),
+ offFail (5),
+ onFail (6),
+ lostComm (7)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The status of the External Switch Gear.
+ unknown(1) indicates the device status is unknown.
+ notInstalled(2) indicates the device is not installed.
+ offOk(3) indicates the device status is off and OK.
+ onOk(4) indicates the device status is on and OK.
+ offFail(5) indicates the device status is off and failed.
+ onFail(6) indicates the device status is on and failed.
+ lostComm(7) indicates the device has lost communication."
+ ::= { upsDiagSubSysExternalSwitchGearEntry 3 }
+
+upsDiagSubSysExternalSwitchGearFirmwareRev OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The firmware revision of the External Switch Gear monitor card."
+ ::= { upsDiagSubSysExternalSwitchGearEntry 4 }
+
+upsDiagSubSysExternalSwitchGearHardwareRev OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The hardware revision of the External Switch Gear monitor card."
+ ::= { upsDiagSubSysExternalSwitchGearEntry 5 }
+
+upsDiagSubSysExternalSwitchGearSerialNum OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The serial number of the External Switch Gear monitor card."
+ ::= { upsDiagSubSysExternalSwitchGearEntry 6 }
+
+upsDiagSubSysExternalSwitchGearManufactureDate OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The date of the manufacture for the External Switch Gear monitor card."
+ ::= { upsDiagSubSysExternalSwitchGearEntry 7 }
+
+upsDiagSubSysDisplayInterfaceCardTableSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of Display Interface Cards attached to the UPS."
+ ::= { upsDiagnosticSubsystem 9 }
+
+upsDiagSubSysDisplayInterfaceCardTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF UpsDiagSubSysDisplayInterfaceCardEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for diagnostics of individual Display Interface Cards."
+ ::= { upsDiagnosticSubsystem 10 }
+
+upsDiagSubSysDisplayInterfaceCardEntry OBJECT-TYPE
+ SYNTAX UpsDiagSubSysDisplayInterfaceCardEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The diagnostics of a Display Interface Card."
+ INDEX { upsDiagSubSysDisplayInterfaceCardIndex}
+ ::= { upsDiagSubSysDisplayInterfaceCardTable 1 }
+
+UpsDiagSubSysDisplayInterfaceCardEntry ::=
+ SEQUENCE {
+ upsDiagSubSysDisplayInterfaceCardFrameIndex INTEGER,
+ upsDiagSubSysDisplayInterfaceCardIndex INTEGER,
+ upsDiagSubSysDisplayInterfaceCardStatus INTEGER
+ }
+
+upsDiagSubSysDisplayInterfaceCardFrameIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The frame index entry."
+ ::= { upsDiagSubSysDisplayInterfaceCardEntry 1 }
+
+upsDiagSubSysDisplayInterfaceCardIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index of the Display Interface Card."
+ ::= { upsDiagSubSysDisplayInterfaceCardEntry 2 }
+
+upsDiagSubSysDisplayInterfaceCardStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ unknown (1),
+ notInstalled (2),
+ offOk (3),
+ onOk (4),
+ offFail (5),
+ onFail (6),
+ lostComm (7)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The status of the Display Interface Card.
+ unknown(1) indicates the device status is unknown.
+ notInstalled(2) indicates the device is not installed.
+ offOk(3) indicates the device status is off and OK.
+ onOk(4) indicates the device status is on and OK.
+ offFail(5) indicates the device status is off and failed.
+ onFail(6) indicates the device status is on and failed.
+ lostComm(7) indicates the device has lost communication."
+ ::= { upsDiagSubSysDisplayInterfaceCardEntry 3 }
+
+upsDiagSubSysDCCircuitBreakerTableSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of DC Circuit Breakers attached to the UPS."
+ ::= { upsDiagnosticSubsystem 11 }
+
+upsDiagSubSysDCCircuitBreakerTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF UpsDiagSubSysDCCircuitBreakerEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for diagnostics of individual DC Circuit Breakers."
+ ::= { upsDiagnosticSubsystem 12 }
+
+upsDiagSubSysDCCircuitBreakerEntry OBJECT-TYPE
+ SYNTAX UpsDiagSubSysDCCircuitBreakerEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The diagnostics of a DC Circuit Breaker."
+ INDEX { upsDiagSubSysDCCircuitBreakerIndex}
+ ::= { upsDiagSubSysDCCircuitBreakerTable 1 }
+
+UpsDiagSubSysDCCircuitBreakerEntry ::=
+ SEQUENCE {
+ upsDiagSubSysDCCircuitBreakerFrameIndex INTEGER,
+ upsDiagSubSysDCCircuitBreakerIndex INTEGER,
+ upsDiagSubSysDCCircuitBreakerStatus INTEGER
+ }
+
+upsDiagSubSysDCCircuitBreakerFrameIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The frame index entry."
+ ::= { upsDiagSubSysDCCircuitBreakerEntry 1 }
+
+upsDiagSubSysDCCircuitBreakerIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index of the DC Circuit Breaker."
+ ::= { upsDiagSubSysDCCircuitBreakerEntry 2 }
+
+upsDiagSubSysDCCircuitBreakerStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ unknown (1),
+ notInstalled (2),
+ opened (3),
+ closed (4)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The status of the DC Circuit Breaker.
+ unknown(1) indicates the circuit breaker status is unknown.
+ notInstalled(2) indicates the circuit breaker is not installed.
+ opened(3) indicates the circuit breaker is opened.
+ closed(4) indicates the circuit breaker is closed."
+ ::= { upsDiagSubSysDCCircuitBreakerEntry 3 }
+
+upsDiagSubSysSystemPowerSupplyTableSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of System Power Supplies attached to the UPS."
+ ::= { upsDiagnosticSubsystem 13 }
+
+upsDiagSubSysSystemPowerSupplyTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF UpsDiagSubSysSystemPowerSupplyEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for diagnostics of individual System Power Supplies."
+ ::= { upsDiagnosticSubsystem 14 }
+
+upsDiagSubSysSystemPowerSupplyEntry OBJECT-TYPE
+ SYNTAX UpsDiagSubSysSystemPowerSupplyEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The diagnostics of a System Power Supply."
+ INDEX { upsDiagSubSysSystemPowerSupplyIndex}
+ ::= { upsDiagSubSysSystemPowerSupplyTable 1 }
+
+UpsDiagSubSysSystemPowerSupplyEntry ::=
+ SEQUENCE {
+ upsDiagSubSysSystemPowerSupplyFrameIndex INTEGER,
+ upsDiagSubSysSystemPowerSupplyIndex INTEGER,
+ upsDiagSubSysSystemPowerSupplyStatus INTEGER
+ }
+
+upsDiagSubSysSystemPowerSupplyFrameIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The frame index entry."
+ ::= { upsDiagSubSysSystemPowerSupplyEntry 1 }
+
+upsDiagSubSysSystemPowerSupplyIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index of a System Power Supply."
+ ::= { upsDiagSubSysSystemPowerSupplyEntry 2 }
+
+upsDiagSubSysSystemPowerSupplyStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ unknown (1),
+ notInstalled (2),
+ offOk (3),
+ onOk (4),
+ offFail (5),
+ onFail (6),
+ lostComm (7)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The status of the System Power Supply.
+ unknown(1) indicates the device status is unknown.
+ notInstalled(2) indicates the device is not installed.
+ offOk(3) indicates the device status is off and OK.
+ onOk(4) indicates the device status is on and OK.
+ offFail(5) indicates the device status is off and failed.
+ onFail(6) indicates the device status is on and failed.
+ lostComm(7) indicates the device has lost communication."
+ ::= { upsDiagSubSysSystemPowerSupplyEntry 3 }
+
+upsDiagSubSysXRCommunicationCardTableSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of XR Communication Cards attached to the UPS."
+ ::= { upsDiagnosticSubsystem 15 }
+
+upsDiagSubSysXRCommunicationCardTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF UpsDiagSubSysXRCommunicationCardEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for diagnostics of individual XR Communication Cards."
+ ::= { upsDiagnosticSubsystem 16 }
+
+upsDiagSubSysXRCommunicationCardEntry OBJECT-TYPE
+ SYNTAX UpsDiagSubSysXRCommunicationCardEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The diagnostics of an XR Communication Card."
+ INDEX { upsDiagSubSysXRCommunicationCardIndex}
+ ::= { upsDiagSubSysXRCommunicationCardTable 1 }
+
+UpsDiagSubSysXRCommunicationCardEntry ::=
+ SEQUENCE {
+ upsDiagSubSysXRCommunicationCardFrameIndex INTEGER,
+ upsDiagSubSysXRCommunicationCardIndex INTEGER,
+ upsDiagSubSysXRCommunicationCardStatus INTEGER
+ }
+
+upsDiagSubSysXRCommunicationCardFrameIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The frame index entry."
+ ::= { upsDiagSubSysXRCommunicationCardEntry 1 }
+
+upsDiagSubSysXRCommunicationCardIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index of an XR Communication Card."
+ ::= { upsDiagSubSysXRCommunicationCardEntry 2 }
+
+upsDiagSubSysXRCommunicationCardStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ unknown (1),
+ notInstalled (2),
+ offOk (3),
+ onOk (4),
+ offFail (5),
+ onFail (6),
+ lostComm (7)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The status of the XR Communication Card.
+ unknown(1) indicates the device status is unknown.
+ notInstalled(2) indicates the device is not installed.
+ offOk(3) indicates the device status is off and OK.
+ onOk(4) indicates the device status is on and OK.
+ offFail(5) indicates the device status is off and failed.
+ onFail(6) indicates the device status is on and failed.
+ lostComm(7) indicates the device has lost communication."
+ ::= { upsDiagSubSysXRCommunicationCardEntry 3 }
+
+upsDiagSubSysExternalPowerFrameBoardTableSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of External Power Frame Boards attached to the UPS."
+ ::= { upsDiagnosticSubsystem 17 }
+
+upsDiagSubSysExternalPowerFrameBoardTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF UpsDiagSubSysExternalPowerFrameBoardEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for diagnostics of individual External Power Frame Boards."
+ ::= { upsDiagnosticSubsystem 18 }
+
+upsDiagSubSysExternalPowerFrameBoardEntry OBJECT-TYPE
+ SYNTAX UpsDiagSubSysExternalPowerFrameBoardEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The diagnostics of an External Power Frame Board."
+ INDEX { upsDiagSubSysExternalPowerFrameBoardIndex}
+ ::= { upsDiagSubSysExternalPowerFrameBoardTable 1 }
+
+UpsDiagSubSysExternalPowerFrameBoardEntry ::=
+ SEQUENCE {
+ upsDiagSubSysExternalPowerFrameBoardFrameIndex INTEGER,
+ upsDiagSubSysExternalPowerFrameBoardIndex INTEGER,
+ upsDiagSubSysExternalPowerFrameBoardStatus INTEGER
+ }
+
+upsDiagSubSysExternalPowerFrameBoardFrameIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The frame index entry."
+ ::= { upsDiagSubSysExternalPowerFrameBoardEntry 1 }
+
+upsDiagSubSysExternalPowerFrameBoardIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index of an External Power Frame Board."
+ ::= { upsDiagSubSysExternalPowerFrameBoardEntry 2 }
+
+upsDiagSubSysExternalPowerFrameBoardStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ unknown (1),
+ notInstalled (2),
+ offOk (3),
+ onOk (4),
+ offFail (5),
+ onFail (6),
+ lostComm (7)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The status of the External Power Frame Board.
+ unknown(1) indicates the device status is unknown.
+ notInstalled(2) indicates the device is not installed.
+ offOk(3) indicates the device status is off and OK.
+ onOk(4) indicates the device status is on and OK.
+ offFail(5) indicates the device status is off and failed.
+ onFail(6) indicates the device status is on and failed.
+ lostComm(7) indicates the device has lost communication."
+ ::= { upsDiagSubSysExternalPowerFrameBoardEntry 3 }
+
+upsDiagSubSysChargerTableSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of Chargers attached to the UPS."
+ ::= { upsDiagnosticSubsystem 19 }
+
+ upsDiagSubSysChargerTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF UpsDiagSubSysChargerEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for diagnostics of individual chargers."
+ ::= { upsDiagnosticSubsystem 20 }
+
+upsDiagSubSysChargerEntry OBJECT-TYPE
+ SYNTAX UpsDiagSubSysChargerEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The diagnostics of a charger."
+ INDEX { upsDiagSubSysChargerIndex}
+ ::= { upsDiagSubSysChargerTable 1 }
+
+UpsDiagSubSysChargerEntry ::=
+ SEQUENCE {
+ upsDiagSubSysChargerFrameIndex INTEGER,
+ upsDiagSubSysChargerIndex INTEGER,
+ upsDiagSubSysChargerStatus INTEGER
+ }
+
+upsDiagSubSysChargerFrameIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The frame index entry."
+ ::= { upsDiagSubSysChargerEntry 1 }
+
+upsDiagSubSysChargerIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index of a charger."
+ ::= { upsDiagSubSysChargerEntry 2 }
+
+upsDiagSubSysChargerStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ unknown (1),
+ notInstalled (2),
+ offOk (3),
+ onOk (4),
+ offFail (5),
+ onFail (6),
+ lostComm (7)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The status of the Charger.
+ unknown(1) indicates the device status is unknown.
+ notInstalled(2) indicates the device is not installed.
+ offOk(3) indicates the device status is off and OK.
+ onOk(4) indicates the device status is on and OK.
+ offFail(5) indicates the device status is off and failed.
+ onFail(6) indicates the device status is on and failed.
+ lostComm(7) indicates the device has lost communication."
+ ::= { upsDiagSubSysChargerEntry 3 }
+
+-- the upsDiagnosticExternalDevices group
+
+upsDiagSwitchGearStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ unknown (1),
+ notInstalled (2),
+ ok (3),
+ fail (4),
+ lostComm (5),
+ overtemp (6)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The status of the Switch Gear.
+ unknown(1) indicates the device status is unknown.
+ notInstalled(2) indicates the device is not installed.
+ ok(3) indicates the device status is OK.
+ fail(4) indicates the device status has failed.
+ lostComm(5) indicates the device has lost communication.
+ overtemp(6) indicates the device has an over temperature condition."
+ ::= { upsDiagSwitchGear 1 }
+
+upsDiagSwitchGearInputSwitchStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ unknown (1),
+ notInstalled (2),
+ opened (3),
+ closed (4)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The status of the Switch Gear Input Switch.
+ unknown(1) indicates the switch status is unknown.
+ notInstalled(2) indicates the switch is not installed.
+ opened(3) indicates the switch is opened.
+ closed(4) indicates the switch is closed."
+ ::= { upsDiagSwitchGear 2 }
+
+upsDiagSwitchGearOutputSwitchStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ unknown (1),
+ notInstalled (2),
+ opened (3),
+ closed (4)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The status of the Switch Gear Output Switch.
+ unknown(1) indicates the switch status is unknown.
+ notInstalled(2) indicates the switch is not installed.
+ opened(3) indicates the switch is opened.
+ closed(4) indicates the switch is closed."
+ ::= { upsDiagSwitchGear 3 }
+
+upsDiagSwitchGearBypassSwitchStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ unknown (1),
+ notInstalled (2),
+ opened (3),
+ closed (4)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The status of the Switch Gear Bypass Switch.
+ unknown(1) indicates the switch status is unknown.
+ notInstalled(2) indicates the switch is not installed.
+ opened(3) indicates the switch is opened.
+ closed(4) indicates the switch is closed."
+ ::= { upsDiagSwitchGear 4 }
+
+upsDiagMCCBBoxStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ unknown (1),
+ notInstalled (2),
+ opened (3),
+ closed (4)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The status of the MCCB Box (Molded Case Circuit Breaker Box) external device.
+ unknown(1) indicates the device status is unknown.
+ notInstalled(2) indicates the device is not installed.
+ opened(3) indicates the circuit is opened.
+ closed(4) indicates the circuit is closed."
+ ::= { upsDiagMCCBBox 1 }
+
+upsDiagTransformerStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ unknown (1),
+ notInstalled (2),
+ ok (3),
+ fail (4),
+ lostComm (5),
+ overtemp (6),
+ opened (7),
+ closed (8)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The status of the External Transformer.
+ unknown(1) indicates the device status is unknown.
+ notInstalled(2) indicates the device is not installed.
+ ok(3) indicates the device status is OK.
+ fail(4) indicates the device status has failed.
+ lostComm(5) indicates the device has lost communication.
+ overtemp(6) indicates the device has an over temperature condition.
+ opened(7) indicates the circuit is opened.
+ closed(8) indicates the circuit is closed."
+ ::= { upsDiagTransformer 1 }
+
+-- the upsDiagnosticComBus group
+
+upsDiagComBusInternalMIMStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ unknown (1),
+ notInstalled (2),
+ ok (3),
+ lostComm (4),
+ rxFailure (5),
+ txFailure (6)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The status of the internal MIM communication bus.
+ unknown(1) indicates the device status is unknown.
+ notInstalled(2) indicates the device is not installed.
+ ok(3) indicates the device status is OK.
+ lostComm(4) indicates the device has lost communication.
+ rxFailure(5) indicates the device has a receive failure.
+ txFailure(6) indicates the device has a transmit failure."
+ ::= { upsDiagnosticComBus 1 }
+
+upsDiagComBusInternalRIMStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ unknown (1),
+ notInstalled (2),
+ ok (3),
+ lostComm (4),
+ rxFailure (5),
+ txFailure (6)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The status of the internal RIM communication bus.
+ unknown(1) indicates the device status is unknown.
+ notInstalled(2) indicates the device is not installed.
+ ok(3) indicates the device status is OK.
+ lostComm(4) indicates the device has lost communication.
+ rxFailure(5) indicates the device has a receive failure.
+ txFailure(6) indicates the device has a transmit failure."
+ ::= { upsDiagnosticComBus 2 }
+
+upsDiagComBusMIMtoRIMStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ unknown (1),
+ notInstalled (2),
+ ok (3),
+ lostComm (4),
+ rxFailure (5),
+ txFailure (6)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The status of the MIM to RIM communication bus.
+ unknown(1) indicates the device status is unknown.
+ notInstalled(2) indicates the device is not installed.
+ ok(3) indicates the device status is OK.
+ lostComm(4) indicates the device has lost communication.
+ rxFailure(5) indicates the device has a receive failure.
+ txFailure(6) indicates the device has a transmit failure."
+ ::= { upsDiagnosticComBus 3 }
+
+upsDiagComBusExternalMIMStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ unknown (1),
+ notInstalled (2),
+ ok (3),
+ lostComm (4),
+ rxFailure (5),
+ txFailure (6)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The status of the external MIM communication bus.
+ unknown(1) indicates the device status is unknown.
+ notInstalled(2) indicates the device is not installed.
+ ok(3) indicates the device status is OK.
+ lostComm(4) indicates the device has lost communication.
+ rxFailure(5) indicates the device has a receive failure.
+ txFailure(6) indicates the device has a transmit failure."
+ ::= { upsDiagnosticComBus 4 }
+
+upsDiagComBusExternalRIMStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ unknown (1),
+ notInstalled (2),
+ ok (3),
+ lostComm (4),
+ rxFailure (5),
+ txFailure (6)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The status of the external RIM communication bus.
+ unknown(1) indicates the device status is unknown.
+ notInstalled(2) indicates the device is not installed.
+ ok(3) indicates the device status is OK.
+ lostComm(4) indicates the device has lost communication.
+ rxFailure(5) indicates the device has a receive failure.
+ txFailure(6) indicates the device has a transmit failure."
+ ::= { upsDiagnosticComBus 5 }
+
+-- the serialPort2Config group
+
+serialPort2Mode OBJECT-TYPE
+ SYNTAX INTEGER {
+ localConsole(1),
+ passthrough(2)
+ }
+ ACCESS read-write
+ STATUS obsolete
+ DESCRIPTION
+ "Setting this variable to passthrough will enable mini's port2
+ behave like a UPS port. Choosing localConsole will enable the port
+ to be used as local console."
+ ::= { serialPort2Config 1 }
+-- the serialPort2Control group
+
+setPulseOnTXD OBJECT-TYPE
+ SYNTAX INTEGER {
+ noSetPulseOnTXD(1),
+ setPulseOnTXD(2),
+ setTXDLow(3),
+ setTXDHigh(4)
+
+ }
+ ACCESS read-write
+ STATUS obsolete
+ DESCRIPTION
+ "Setting this variable to setPulseOnTXD(2)
+ causes adapter to generate a PULSE on TXD pin of serial port 2.
+ The duration in the prototype implementation will be 1 second.
+
+ Setting this value to noSetPulseOnTXD(1) has no
+ effect.
+
+ The value noSetPulseOnTXD(1) will always be returned
+ when the variable is read.
+
+ Setting this value to setTXDLow(3), or setTXDHigh(4) will keep TXD
+ always low or high respectively."
+ ::= { serialPort2Control 1 }
+
+-- the sPDUIdent group
+
+sPDUIdentHardwareRev OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The hardware revision of the PDU. This value
+ is set at the factory."
+ ::= { sPDUIdent 1 }
+
+sPDUIdentFirmwareRev OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "An 8 byte ID string identifying the PDU firmware revision.
+ This value is set at the factory."
+ ::= { sPDUIdent 2 }
+
+
+sPDUIdentDateOfManufacture OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The date when the PDU was manufactured in mm/dd/yy format.
+ This value is set at the factory. The year 2000 will be
+ represented by 00."
+ ::= { sPDUIdent 3 }
+
+sPDUIdentModelNumber OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A 10-character string identifying the model number of
+ the PDU internal. This value is set at the factory."
+ ::= { sPDUIdent 4 }
+
+sPDUIdentSerialNumber OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A 12-character string identifying the serial number of
+ the PDU internal microprocessor. This value is set at
+ the factory."
+ ::= { sPDUIdent 5 }
+
+
+-- the sPDUMasterControl group
+
+sPDUMasterControlSwitch OBJECT-TYPE
+ SYNTAX INTEGER {
+ turnAllOnNow (1),
+ turnAllOnSequence (2),
+ turnAllOffNow (3),
+ rebootAllNow (4),
+ rebootAllSequence (5),
+ noCommand (6),
+ turnAllOffSequence (7)
+ }
+
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Setting this OID to turnAllOnNow (1) will turn all outlets
+ on immediately.
+
+ Setting this OID to turnAllOnSequence (2) will turn all outlets
+ on as defined by each outlet's sPDUOutletPowerOnTime OID value.
+
+ Setting this OID to turnAllOff (3) will turn all outlets
+ off immediately.
+
+ Setting this OID to rebootAllNow (4) will reboot all outlets
+ immediately.
+
+ For MasterSwitch firmware version 1.X, setting this OID to
+ rebootAllSequence (5) reboots all outlets, with power returned
+ to the outlets in the sequence defined by each outlet's
+ sPDUOutletPowerOnTime OID value.
+
+ For MasterSwitch firmware version 2.X, setting this OID to
+ rebootAllSequence (5) will cause a turnAllOffSequence to be performed.
+ Once all outlets are off, the MasterSwitch will then delay the
+ sPDUMasterConfigReboot OID time, and then perform a turnAllOnSequence.
+
+ For MasterSwitch firmware version 2.X, setting this OID to
+ turnAllOffSequence (7) will turn all outlets off as defined by
+ each outlet's sPDUOutletPowerOffTime OID value.
+
+ For MasterSwitch firmware version 1.X, setting this OID to
+ turnAllOffSequence (7) will have no effect.
+
+ Getting this OID will return the noCommand (6) value."
+
+ ::= { sPDUMasterControl 1 }
+
+
+sPDUMasterState OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this OID will cause the status of all outlets to be
+ returned. This OID is provided for informational purposes only.
+ To change the outlet state, the user should use the sPDUOutletCtl
+ OID in the sPDUOutletControlTable.
+
+ The format of the data returned is a character string consisting
+ of the word 'On' if the outlet is on or 'Off' if the outlet is
+ off. At least one space will delimit each outlet entry in the
+ string.
+
+ If the outlet states are unknown, the character string 'Unknown'
+ will be returned. This signifies that there is an inconsistancy
+ in the PDU. In the rare case that this should happen, the user
+ is advised to shut down all equipment powered by the PDU and
+ then cycle the PDU's power. This will put the PDU in a consistent
+ state."
+
+ ::= { sPDUMasterControl 2 }
+
+sPDUMasterPending OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this OID will cause the command pending status of all outlets to be returned.
+
+ The format of the data returned is a character string consisting
+ of the word 'Yes' if a command is pending for the outlet or 'No'
+ if there is no command pending for the outlet. At least one
+ space will delimit each outlet entry in the string.
+
+ If the pending states are unknown, the character string 'Unknown'
+ will be returned. This signifies that there is an inconsistancy
+ in the PDU. In the rare case that this should happen, the user
+ is advised to shut down all equipment powered by the PDU and then
+ cycle the PDU's power. This will put the PDU in a consistent state."
+ ::= { sPDUMasterControl 3 }
+
+
+-- the sPDUMasterConfig group
+
+sPDUMasterConfigPowerOn OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ " The amount of delay, in seconds, between when
+ power is provided to the PDU and when the PDU
+ provides basic master power to the outlets.
+
+ Allowed values are:
+
+ -1 never apply power automatically.
+ 0 apply power immediately.
+ 15 apply power in 15 seconds.
+ 30 apply power in 30 seconds.
+ 45 apply power in 45 seconds.
+ 60 apply power in 60 seconds (1 minute).
+ 120 apply power in 120 seconds (2 minutes).
+ 300 apply power in 300 seconds (5 minutes).
+
+ If a value other than a supported value is provided in a
+ set request, the PDU interprets it as the next lower
+ acceptable value. If the provided value is lower than
+ the lowest acceptable value, the lowest acceptable
+ value is used."
+
+ ::= { sPDUMasterConfig 1 }
+
+sPDUMasterConfigReboot OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "During a reboot sequence, power is turned off and then
+ back on. This OID defines the amount of time to wait,
+ in seconds, after turning the power off, at the start
+ of the sequence, before turning power back on, at the
+ end of the reboot sequence.
+
+ Allowed values are:
+
+ 5 wait 5 seconds between off/on.
+ 10 wait 10 seconds between off/on.
+ 15 wait 15 seconds between off/on.
+ 20 wait 20 seconds between off/on.
+ 30 wait 30 seconds between off/on.
+ 45 wait 45 seconds between off/on.
+ 60 wait 60 seconds (1 minute) between off/on.
+
+ If a value other than a supported value is provided in a
+ set request, the PDU interprets it as the next lower
+ acceptable value. If the provided value is lower than
+ the lowest acceptable value, the lowest acceptable
+ value is used.
+
+ This OID is read-only for the MasterSwitch version 2.X and is the
+ maximum sPDUOutletRebootDuration OID of the individual outlets."
+
+ ::= { sPDUMasterConfig 2 }
+
+sPDUMasterConfigPDUName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The name of the PDU. The maximum value is 20 characters."
+ ::= { sPDUMasterConfig 3 }
+
+
+
+-- the sPDUOutletControl group
+sPDUOutletControlTableSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of outlets for the PDU."
+ ::= { sPDUOutletControl 1 }
+
+
+sPDUOutletControlTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF OutletControlEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for control of individual outlet switches. The number of
+ entries is contained in the sPDUOutletControlTableSize OID."
+ ::= { sPDUOutletControl 2 }
+
+sPDUOutletControlEntry OBJECT-TYPE
+ SYNTAX OutletControlEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The outlets to control."
+ INDEX { sPDUOutletControlIndex}
+ ::= { sPDUOutletControlTable 1 }
+
+OutletControlEntry ::=
+ SEQUENCE {
+ sPDUOutletControlIndex INTEGER,
+ sPDUOutletPending INTEGER,
+ sPDUOutletCtl INTEGER,
+ sPDUOutletCtlName DisplayString
+ }
+
+sPDUOutletControlIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the outlet entry."
+ ::= { sPDUOutletControlEntry 1 }
+
+sPDUOutletPending OBJECT-TYPE
+ SYNTAX INTEGER{
+ commandPending (1),
+ noCommandPending (2),
+ commandPendingUnknown (3)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Reports whether the current outlet has a pending command.
+
+ If the commandPendingUnknown (3) value is returned, all
+ devices powered by the PDU should be shut down. The PDU's
+ power should then be cycled to clear this condition."
+
+ ::= { sPDUOutletControlEntry 2 }
+
+sPDUOutletCtl OBJECT-TYPE
+ SYNTAX INTEGER {
+ outletOn (1),
+ outletOff (2),
+ outletReboot (3),
+ outletUnknown (4),
+ outletOnWithDelay (5),
+ outletOffWithDelay (6),
+ outletRebootWithDelay (7)
+ }
+
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this variable will return the outlet state. If
+ the outlet is on, the outletOn (1) value will be returned.
+ If the outlet is off, the outletOff (2) value will be
+ returned.
+
+ If the state of the outlet cannot be determined, the
+ outletUnknown (4) value will be returned. If the
+ outletUnknown condition should occur, all devices
+ powered by the PDU should be shut down. The PDU's power
+ should then be cycled to clear this condition.
+
+ Setting this variable to outletOn (1) will turn the outlet on.
+
+ Setting this variable to outletOff (2) will turn the outlet off.
+
+ Setting this variable to outletReboot (3) will reboot the outlet.
+
+ Setting this variable to outletOnWithDelay (5) will turn the outlet on
+ after the sPDUOutletPowerOnTime OID has elapsed. This option is not
+ valid for MasterSwitch firmware version 1.X.
+
+ Setting this variable to outletOffWithDelay (6) will turn the outlet off
+ after the sPDUOutletPowerOffTime OID has elapsed. This option is not valid
+ for MasterSwitch firmware version 1.X.
+
+ Setting this variable to outletRebootWithDelay (7) will turn the outlet off
+ after the sPDUOutletPowerOffTime OID has elapsed, wait the sPDUOutletRebootDuration
+ OID time, then turn the outlet back on.
+ This option is not valid for MasterSwitch firmware version 1.X."
+
+ ::= { sPDUOutletControlEntry 3 }
+
+sPDUOutletCtlName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The name of the outlet. Maximum size is 20 characters.
+ This OID is provided for informational purposes only.
+ This value is set by the sPDUOutletName OID."
+
+ ::= { sPDUOutletControlEntry 4 }
+
+-- the sPDUOutletConfig group
+sPDUOutletConfigTableSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of outlets for the PDU."
+ ::= { sPDUOutletConfig 1 }
+
+sPDUOutletConfigTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF SPDUOutletConfigEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The list of outlets to configure. The number of
+ entries is defined by the sPDUOutletConfigTableSize
+ OID."
+
+ ::= { sPDUOutletConfig 2 }
+
+sPDUOutletConfigEntry OBJECT-TYPE
+ SYNTAX SPDUOutletConfigEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The outlets to control."
+ INDEX { sPDUOutletConfigIndex}
+ ::= { sPDUOutletConfigTable 1 }
+
+SPDUOutletConfigEntry ::=
+ SEQUENCE {
+ sPDUOutletConfigIndex INTEGER,
+ sPDUOutletPowerOnTime INTEGER,
+ sPDUOutletName DisplayString,
+ sPDUOutletPowerOffTime INTEGER,
+ sPDUOutletRebootDuration INTEGER
+ }
+
+sPDUOutletConfigIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the outlet entry."
+ ::= { sPDUOutletConfigEntry 1 }
+
+sPDUOutletPowerOnTime OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The amount of time (in seconds) the outlet will delay
+ powering on when the MasterSwitch is powered on.
+
+ Allowed values are:
+
+ -1 never power on automatically.
+ 0 power on with the Master Switch.
+ 15 power on 15 seconds after the MasterSwitch has power applied.
+ 30 power on 30 seconds after the MasterSwitch has power applied.
+ 45 power on 45 seconds after the MasterSwitch has power applied.
+ 60 power on 60 seconds (1 minute) after the MasterSwitch has power applied.
+ 120 power on 120 seconds (2 minutes) after the MasterSwitch has power applied.
+ 300 power on 300 seconds (5 minutes) after the MasterSwitch has power applied.
+
+ If a value other than a supported value is provided in a
+ set request, the PDU interprets it as the next lower
+ acceptable value. If the provided value is lower than
+ the lowest acceptable value, the lowest acceptable
+ value is used."
+
+ ::= { sPDUOutletConfigEntry 2 }
+
+sPDUOutletName OBJECT-TYPE
+ SYNTAX DisplayString ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The name of the outlet. Maximum size is 20 characters."
+
+ ::= { sPDUOutletConfigEntry 3 }
+
+sPDUOutletPowerOffTime OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The amount of time (in seconds) the outlet will delay
+ powering off.
+
+ Allowed values are:
+
+ -1 never power off automatically.
+ 0 power off with the MasterSwitch.
+ 15 power off 15 seconds after being commanded.
+ 30 power off 30 seconds after being commanded.
+ 45 power off 45 seconds after being commanded.
+ 60 power off 60 seconds (1 minute) after being commanded.
+ 120 power off 120 seconds (2 minutes) after being commanded.
+ 300 power off 300 seconds (5 minutes) after being commanded.
+
+ If a value other than a supported value is provided in a
+ set request, the PDU interprets it as the next lower
+ acceptable value. If the provided value is lower than
+ the lowest acceptable value, the lowest acceptable
+ value is used.
+
+ This OID is not available for MasterSwitch firmware version 1.X."
+
+ ::= { sPDUOutletConfigEntry 4 }
+
+sPDUOutletRebootDuration OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "During a reboot sequence, power is turned off and then
+ back on. This OID defines the amount of time to wait,
+ in seconds, after turning the power off, at the start
+ of the sequence, before turning power back on, at the
+ end of the reboot sequence.
+
+ Allowed values are:
+
+ 5 wait 5 seconds between off/on.
+ 10 wait 10 seconds between off/on.
+ 15 wait 15 seconds between off/on.
+ 20 wait 20 seconds between off/on.
+ 30 wait 30 seconds between off/on.
+ 45 wait 45 seconds between off/on.
+ 60 wait 60 seconds (1 minute) between off/on.
+
+ If a value other than a supported value is provided in a
+ set request, the PDU interprets it as the next lower
+ acceptable value. If the provided value is lower than
+ the lowest acceptable value, the lowest acceptable
+ value is used.
+
+ This OID is not available for MasterSwitch firmware version 1.X."
+
+ ::= { sPDUOutletConfigEntry 5 }
+
+
+-- the sPDUIdentVM group
+
+sPDUIdentVMTableSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of MasterSwitch VMs controllable
+ by this IP address."
+ ::= { sPDUIdentVM 1 }
+
+
+sPDUIdentVMTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF IdentVMEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for query of the individual MasterSwitch VMs.
+ The number of entries is contained in the
+ sPDUIdentVMTableSize OID."
+ ::= { sPDUIdentVM 2 }
+
+sPDUIdentVMEntry OBJECT-TYPE
+ SYNTAX IdentVMEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The MasterSwitch VMs to query."
+ INDEX { sPDUIdentVMIndex}
+ ::= { sPDUIdentVMTable 1 }
+
+IdentVMEntry ::=
+ SEQUENCE {
+ sPDUIdentVMIndex INTEGER,
+ sPDUIdentNameVM DisplayString,
+ sPDUIdentHardwareRevVM DisplayString,
+ sPDUIdentFirmwareRevVM DisplayString,
+ sPDUIdentDateOfManufactureVM DisplayString,
+ sPDUIdentModelNumberVM DisplayString,
+ sPDUIdentSerialNumberVM DisplayString
+ }
+
+sPDUIdentVMIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the MasterSwitch VM entry."
+ ::= { sPDUIdentVMEntry 1 }
+
+sPDUIdentNameVM OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A 23-character string identifying the
+ MasterSwitch VM. "
+ ::= { sPDUIdentVMEntry 2 }
+
+sPDUIdentHardwareRevVM OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The hardware version of the MasterSwitch VM.
+ This value is set at the factory."
+ ::= { sPDUIdentVMEntry 3 }
+
+sPDUIdentFirmwareRevVM OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "An 6-character ID string identifying the MasterSwitch VM
+ firmware version. This value is set at the factory."
+ ::= { sPDUIdentVMEntry 4 }
+
+
+sPDUIdentDateOfManufactureVM OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The date when the MasterSwitch VM was manufactured in mm/dd/yyyy format.
+ This value is set at the factory. "
+ ::= { sPDUIdentVMEntry 5 }
+
+sPDUIdentModelNumberVM OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A 17-character string identifying the model number of
+ the MasterSwitch VM. This value is set at the factory."
+ ::= { sPDUIdentVMEntry 6 }
+
+sPDUIdentSerialNumberVM OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A 17-character string identifying the serial number of
+ the MasterSwitch VM. This value is set at the factory."
+ ::= { sPDUIdentVMEntry 7 }
+
+
+-- the sPDUMasterControlVM group
+
+sPDUMasterControlVMTableSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of MasterSwitch VMs controllable
+ by this IP address."
+ ::= { sPDUMasterControlVM 1 }
+
+
+sPDUMasterControlVMTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF MasterControlVMEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for control of the individual MasterSwitch VMs.
+ The number of entries is contained in the
+ sPDUMasterControlVMTableSize OID."
+ ::= { sPDUMasterControlVM 2 }
+
+sPDUMasterControlVMEntry OBJECT-TYPE
+ SYNTAX MasterControlVMEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The MasterSwitch VMs to control."
+ INDEX { sPDUMasterControlVMIndex}
+ ::= { sPDUMasterControlVMTable 1 }
+
+MasterControlVMEntry ::=
+ SEQUENCE {
+ sPDUMasterControlVMIndex INTEGER,
+ sPDUMasterControlVMName DisplayString,
+ sPDUMasterControlVMCommand INTEGER
+ }
+
+sPDUMasterControlVMIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the MasterSwitch VM entry."
+ ::= { sPDUMasterControlVMEntry 1 }
+
+sPDUMasterControlVMName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The name of the MasterSwitch VM. The maximum
+ value is 23 characters. The name is set by
+ using the sPDUMasterConfigVMName OID."
+ ::= { sPDUMasterControlVMEntry 2 }
+
+sPDUMasterControlVMCommand OBJECT-TYPE
+ SYNTAX INTEGER {
+ noCommandAllVM (1),
+ immediateAllOnVM (2),
+ immediateAllOffVM (3),
+ immediateAllRebootVM (4),
+ delayedAllOnVM (5),
+ delayedAllOffVM (6),
+ sequencedAllRebootVM (7),
+ delayedAllRebootVM (8),
+ delayedSequenceAllRebootVM (9),
+ cancelAllPendingCommandsVM (10),
+ audioAlarmMute (11)
+ }
+
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Setting this OID to immediateAllOnVM (2) will turn all outlets
+ on immediately.
+
+ Setting this OID to immediateAllOffVM (3) will turn all outlets
+ off immediately.
+
+ Setting this OID to immediateAllRebootVM (4) will reboot all outlets
+ immediately.
+
+ Setting this OID to delayedAllOnVM (5) will turn all outlets on as
+ defined by each outlet's sPDUOutletConfigVMPowerOnTime OID value.
+
+ Setting this OID to delayedAllOffVM (6) will turn all outlets
+ off as defined by each outlet's sPDUOutletConfigVMPowerOffTime OID value.
+
+ Setting this OID to sequencedAllRebootVM (7) will cause a
+ immediateAllOffVM command to be performed. The MasterSwitch VM will
+ then delay the sPDUMasterStatusVMRebootDuration OID time, and then
+ perform a delayedAllOnVM command.
+
+ Setting this OID to delayedAllRebootVM (8) will cause a delayedAllOffVM
+ command to be performed. Each outlet will then wait its
+ sPDUOutletConfigVMRebootDuration before returning power to the outlet.
+
+ Setting this OID to delayedSequenceAllRebootVM (9) will cause a
+ delayedAllOffVM command to be performed. Once all outlets are off,
+ the MasterSwitch VM will then delay the sPDUMasterStatusVMRebootDuration
+ OID time, and then perform a delayedAllOnVM command.
+
+ Setting this OID to cancelAllPendingCommandsVM (10) will cause all pending
+ commands on the MasterSwitch VM to be canceled.
+
+
+ Setting this OID to audioAlarmMute (11) will temporarily silence the audible
+ alarm for the duration of the current overload condition. The audible alarm
+ will be activated on subsequent overload alarms.
+
+ Getting this OID will return the noCommandAllVM (1) value."
+ ::= { sPDUMasterControlVMEntry 3 }
+
+
+-- the sPDUMasterConfigVM group
+
+sPDUMasterConfigVMTableSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of MasterSwitch VMs configurable
+ by this IP address."
+ ::= { sPDUMasterConfigVM 1 }
+
+
+sPDUMasterConfigVMTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF MasterConfigVMEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for configuration of the individual MasterSwitch VMs.
+ The number of entries is contained in the
+ sPDUMasterConfigVMTableSize OID."
+ ::= { sPDUMasterConfigVM 2 }
+
+sPDUMasterConfigVMEntry OBJECT-TYPE
+ SYNTAX MasterConfigVMEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The MasterSwitch VMs to configure."
+ INDEX { sPDUMasterConfigVMIndex}
+ ::= { sPDUMasterConfigVMTable 1 }
+
+MasterConfigVMEntry ::=
+ SEQUENCE {
+ sPDUMasterConfigVMIndex INTEGER,
+ sPDUMasterConfigVMName DisplayString,
+ sPDUMasterConfigVMColdstartDelay INTEGER,
+ sPDUMasterConfigVMAudioAlarmActivated INTEGER,
+ sPDUMasterConfigVMHighLoadWarningThreshold INTEGER,
+ sPDUMasterConfigVMLowLoadWarningThreshold INTEGER,
+ sPDUMasterConfigVMOverloadRestriction INTEGER
+ }
+
+sPDUMasterConfigVMIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the MasterSwitch VM entry."
+ ::= { sPDUMasterConfigVMEntry 1 }
+
+
+sPDUMasterConfigVMName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The name of the MasterSwitch VM. Maximum size is 23 characters."
+ ::= { sPDUMasterConfigVMEntry 2 }
+
+sPDUMasterConfigVMColdstartDelay OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ " The amount of delay, in seconds, between when
+ power is provided to the MasterSwitch VM and
+ when the MasterSwitch VM provides basic master
+ power to the outlets.
+
+ Allowed values are:
+
+ -1 never apply power automatically.
+ 0 apply power immediately.
+ 15 apply power in 15 seconds.
+ 30 apply power in 30 seconds.
+ 45 apply power in 45 seconds.
+ 60 apply power in 60 seconds (1 minute).
+ 120 apply power in 120 seconds (2 minutes).
+ 300 apply power in 300 seconds (5 minutes).
+
+ If a value other than a supported value is provided in a
+ set request, the MasterSwitch VM interprets it as the next lower
+ acceptable value. If the provided value is lower than
+ the lowest acceptable value, the lowest acceptable
+ value is used."
+ ::= { sPDUMasterConfigVMEntry 3 }
+
+sPDUMasterConfigVMAudioAlarmActivated OBJECT-TYPE
+ SYNTAX INTEGER {
+ audioAlarmActiveNever (1),
+ audioAlarmActiveOnOverload (2),
+ audioAlarmActiveOnOverloadImminent (3)
+ }
+
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Setting this OID to audioAlarmActiveNever (1) will disable
+ the audio alarm on the MasterSwitch VM.
+
+ Setting this OID to audioAlarmActiveOnOverload (2) will
+ activate the audio alarm on the MasterSwitch VM when an
+ overload condition is present.
+
+ Setting this OID to audioAlarmActiveOnOverloadImminent (3)
+ will activate the audio alarm on the MasterSwitch VM when
+ the load on the MasterSwitch VM has surpassed the
+ sPDUMasterConfigVMHighLoadWarningThreshold OID value."
+ ::= { sPDUMasterConfigVMEntry 4 }
+
+sPDUMasterConfigVMHighLoadWarningThreshold OBJECT-TYPE
+ SYNTAX INTEGER (0..100)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "A threshold that indicates the power consumption of
+ the load is nearing an overload condition. It is
+ represented as a percentage of full load."
+ ::= { sPDUMasterConfigVMEntry 5 }
+
+sPDUMasterConfigVMLowLoadWarningThreshold OBJECT-TYPE
+ SYNTAX INTEGER (0..100)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "A threshold that indicates the power consumption of
+ the load is nearing a low consumption condition. It is
+ represented as a percentage of full load."
+ ::= { sPDUMasterConfigVMEntry 6 }
+
+sPDUMasterConfigVMOverloadRestriction OBJECT-TYPE
+ SYNTAX INTEGER {
+ alwaysAllowTurnON (1),
+ restrictOnWarning (2),
+ restrictOnOverload (3)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "This OID controls the behavior of the MasterSwitch VM
+ when an overload condition is possible and additional
+ outlets are requested to be turned on.
+
+ Setting this OID to alwaysAllowTurnON (1) will always allow
+ the outlets to turn on.
+
+ Setting this OID to restrictOnWarning (2) will not allow
+ outlets to turn on if the sPDUMasterConfigVMHighLoadWarningThreshold
+ OID is exceeded.
+
+ Setting this OID to restrictOnOverload (3) will not allow
+ outlets to turn on if the MasterSwitch Vm is in an
+ overload condition."
+ ::= { sPDUMasterConfigVMEntry 7 }
+
+-- the sPDUMasterStatusVM group
+
+sPDUMasterStatusVMTableSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of MasterSwitch VMs at
+ this IP address."
+ ::= { sPDUMasterStatusVM 1 }
+
+
+sPDUMasterStatusVMTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF MasterStatusVMEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for gathering of status from the individual
+ MasterSwitch VMs. The number of entries is contained
+ in the sPDUMasterStatusVMTableSize OID."
+ ::= { sPDUMasterStatusVM 2 }
+
+sPDUMasterStatusVMEntry OBJECT-TYPE
+ SYNTAX MasterStatusVMEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The MasterSwitch VMs to gather status from."
+ INDEX { sPDUMasterStatusVMIndex}
+ ::= { sPDUMasterStatusVMTable 1 }
+
+MasterStatusVMEntry ::=
+ SEQUENCE {
+ sPDUMasterStatusVMIndex INTEGER,
+ sPDUMasterStatusVMName DisplayString,
+ sPDUMasterStatusVMCommandPending INTEGER,
+ sPDUMasterStatusVMOverloadCondition INTEGER,
+ sPDUMasterStatusVMLowLoadCondition INTEGER,
+ sPDUMasterStatusVMCurrentLoad INTEGER,
+ sPDUMasterStatusVMMaxLoad INTEGER,
+ sPDUMasterStatusVMOutletCount INTEGER,
+ sPDUMasterStatusVMRebootDuration INTEGER
+ }
+
+sPDUMasterStatusVMIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the MasterSwitch VM entry."
+ ::= { sPDUMasterStatusVMEntry 1 }
+
+sPDUMasterStatusVMName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The name of the MasterSwitch VM. Maximum size is 23 characters."
+ ::= { sPDUMasterStatusVMEntry 2 }
+
+sPDUMasterStatusVMCommandPending OBJECT-TYPE
+ SYNTAX INTEGER {
+ commandPendingMasterTrueVM (1),
+ commandPendingMasterFalseVM (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this OID will return commandPendingMasterTrueVM (1)
+ if the MasterSwitch VM has a pending command on any of its
+ outlets.
+
+ commandPendingMasterFalseVM (2) will be returned if there are
+ no pending commands."
+ ::= { sPDUMasterStatusVMEntry 3 }
+
+sPDUMasterStatusVMOverloadCondition OBJECT-TYPE
+ SYNTAX INTEGER {
+ overloadConditionTrueVM (1),
+ overloadConditionFalseVM (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this OID will return overloadConditionTrueVM (1)
+ if the sPDUMasterConfigVMHighLoadWarningThreshold OID is
+ violated.
+
+ overloadConditionFalseVM (2) will be returned if the
+ sPDUMasterConfigVMHighLoadWarningThreshold OID is not
+ violated."
+ ::= { sPDUMasterStatusVMEntry 4 }
+
+sPDUMasterStatusVMLowLoadCondition OBJECT-TYPE
+ SYNTAX INTEGER {
+ lowLoadConditionTrueVM (1),
+ lowLoadConditionFalseVM (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this OID will return lowLoadConditionTrueVM (1)
+ if the sPDUMasterConfigVMLowLoadWarningThreshold OID is
+ violated.
+
+ lowLoadConditionFalseVM (2) will be returned if the
+ sPDUMasterConfigVMHighLoadWarningThreshold OID is not
+ violated. "
+ ::= { sPDUMasterStatusVMEntry 5 }
+
+sPDUMasterStatusVMCurrentLoad OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this OID will return the total amount of power
+ being consumed by the load. It is represented as a
+ percentage of full load."
+ ::= { sPDUMasterStatusVMEntry 6 }
+
+sPDUMasterStatusVMMaxLoad OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this OID will return the total amount of power
+ that this MasterSwitch VM can provide. It is represented
+ in Amps."
+ ::= { sPDUMasterStatusVMEntry 7 }
+
+sPDUMasterStatusVMOutletCount OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this OID will return the number of controllable
+ outlets for this MasterSwitch VM."
+ ::= { sPDUMasterStatusVMEntry 8 }
+
+sPDUMasterStatusVMRebootDuration OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this OID will return the largest
+ sPDUOutletConfigVMRebootDuration OID time
+ for this MasterSwitch VM."
+ ::= { sPDUMasterStatusVMEntry 9 }
+
+-- the sPDUOutletControlVM group
+
+
+sPDUOutletControlVMTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF OutletControlVMEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for control of individual outlet switches. The number of
+ entries is contained in the sPDUMasterStatusOutletCount OID."
+ ::= { sPDUOutletControlVM 1 }
+
+sPDUOutletControlVMEntry OBJECT-TYPE
+ SYNTAX OutletControlVMEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The outlets to control."
+ INDEX { sPDUOutletControlVMIndex, sPDUOutletControlVMOutletIndex }
+ ::= { sPDUOutletControlVMTable 1 }
+
+OutletControlVMEntry ::=
+ SEQUENCE {
+ sPDUOutletControlVMIndex INTEGER,
+ sPDUOutletControlVMName DisplayString,
+ sPDUOutletControlVMOutletIndex INTEGER,
+ sPDUOutletControlVMOutletName DisplayString,
+ sPDUOutletControlVMOutletCommand INTEGER
+ }
+
+sPDUOutletControlVMIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the MasterSwitch VM."
+ ::= { sPDUOutletControlVMEntry 1 }
+
+sPDUOutletControlVMName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The name of the MasterSwitch VM. Maximum size is 23 characters.
+ This OID is provided for informational purposes only."
+ ::= { sPDUOutletControlVMEntry 2 }
+
+sPDUOutletControlVMOutletIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the outlet entry."
+ ::= { sPDUOutletControlVMEntry 3 }
+
+sPDUOutletControlVMOutletName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The name of the outlet. Maximum size is 23 characters.
+ This OID is provided for informational purposes only."
+ ::= { sPDUOutletControlVMEntry 4 }
+
+sPDUOutletControlVMOutletCommand OBJECT-TYPE
+ SYNTAX INTEGER {
+ immediateOnVM (1),
+ immediateOffVM (2),
+ immediateRebootVM (3),
+ delayedOnVM (4),
+ delayedOffVM (5),
+ delayedRebootVM (6),
+ cancelPendingCommandVM (7)
+
+ }
+
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this variable will return the outlet state. If
+ the outlet is on, the immediateOnVM (1) value will be returned.
+ If the outlet is off, the immediateOffVM (2) value will be
+ returned.
+
+
+ Setting this variable to immediateOnVM (1) will immediately turn the outlet on.
+
+ Setting this variable to immediateOffVM (2) will immediately turn the outlet off.
+
+ Setting this variable to immediateRebootVM (3) will immediately reboot the outlet.
+
+ Setting this variable to delayedOnVM (4) will turn the outlet on
+ after the sPDUOutletConfigVMPowerOnTime OID time has elapsed.
+
+ Setting this variable to delayedOffVM (5) will turn the outlet off
+ after the sPDUOutletConfigVMPowerOffTime OID time has elapsed.
+
+ Setting this variable to delayedRebootVM (6) will cause the
+ MasterSwitch VM to perform a delayedOffVM command, wait the
+ sPDUOutletConfigVMRebootDuration OID time, and then perform the
+ immediateOnVM command.
+
+ Setting this variable to cancelPendingCommandVM (7) will cause any
+ pending command to this outlet to be canceled."
+ ::= { sPDUOutletControlVMEntry 5 }
+
+-- the sPDUOutletConfigVM group
+
+sPDUOutletConfigVMTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF OutletConfigVMEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for configuration of individual outlets. The number of
+ entries is contained in the sPDUMasterStatusOutletCount OID."
+ ::= { sPDUOutletConfigVM 1 }
+
+sPDUOutletConfigVMEntry OBJECT-TYPE
+ SYNTAX OutletConfigVMEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The outlets to configure."
+ INDEX { sPDUOutletConfigVMIndex, sPDUOutletConfigVMOutletIndex }
+ ::= { sPDUOutletConfigVMTable 1 }
+
+OutletConfigVMEntry ::=
+ SEQUENCE {
+ sPDUOutletConfigVMIndex INTEGER,
+ sPDUOutletConfigVMName DisplayString,
+ sPDUOutletConfigVMOutletIndex INTEGER,
+ sPDUOutletConfigVMOutletName DisplayString,
+ sPDUOutletConfigVMPowerOnTime INTEGER,
+ sPDUOutletConfigVMPowerOffTime INTEGER,
+ sPDUOutletConfigVMRebootDuration INTEGER
+ }
+
+sPDUOutletConfigVMIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the MasterSwitch VM."
+ ::= { sPDUOutletConfigVMEntry 1 }
+
+sPDUOutletConfigVMName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The name of the MasterSwitch VM. Maximum size is 23 characters."
+ ::= { sPDUOutletConfigVMEntry 2 }
+
+sPDUOutletConfigVMOutletIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the outlet entry."
+ ::= { sPDUOutletConfigVMEntry 3 }
+
+
+sPDUOutletConfigVMOutletName OBJECT-TYPE
+ SYNTAX DisplayString ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The name of the outlet. Maximum size is 23 characters."
+ ::= { sPDUOutletConfigVMEntry 4 }
+
+sPDUOutletConfigVMPowerOnTime OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The amount of time (in seconds) the outlet will delay
+ powering on at coldstart or when a command that requires
+ a turn-on delay is issued.
+
+ Allowed values are:
+
+ -1 never power on.
+ 0 power on immediately.
+ 15 power on 15 seconds after being commanded.
+ 30 power on 30 seconds after being commanded.
+ 45 power on 45 seconds after being commanded.
+ 60 power on 60 seconds (1 minute) after being commanded.
+ 120 power on 120 seconds (2 minutes) after being commanded.
+ 300 power on 300 seconds (5 minutes) after being commanded.
+
+ If a value other than a supported value is provided in a
+ set request, the MasterSwitch VM interprets it as the next lower
+ acceptable value. If the provided value is lower than
+ the lowest acceptable value, the lowest acceptable
+ value is used."
+ ::= { sPDUOutletConfigVMEntry 5 }
+
+
+sPDUOutletConfigVMPowerOffTime OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The amount of time (in seconds) the outlet will delay
+ powering off when a command that requires
+ a turn-off delay is issued.
+
+
+ Allowed values are:
+
+ -1 never power off automatically.
+ 0 power off immediately.
+ 15 power off 15 seconds after being commanded.
+ 30 power off 30 seconds after being commanded.
+ 45 power off 45 seconds after being commanded.
+ 60 power off 60 seconds (1 minute) after being commanded.
+ 120 power off 120 seconds (2 minutes) after being commanded.
+ 300 power off 300 seconds (5 minutes) after being commanded.
+
+ If a value other than a supported value is provided in a
+ set request, the MasterSwitch VM interprets it as the next lower
+ acceptable value. If the provided value is lower than
+ the lowest acceptable value, the lowest acceptable
+ value is used."
+ ::= { sPDUOutletConfigVMEntry 6 }
+
+sPDUOutletConfigVMRebootDuration OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "During a reboot sequence, power is turned off and then
+ back on. This OID defines the amount of time to wait,
+ in seconds, after turning the power off, at the start
+ of the sequence, before turning power back on, at the
+ end of the reboot sequence.
+
+ Allowed values are:
+
+ 5 wait 5 seconds between off/on.
+ 10 wait 10 seconds between off/on.
+ 15 wait 15 seconds between off/on.
+ 20 wait 20 seconds between off/on.
+ 30 wait 30 seconds between off/on.
+ 45 wait 45 seconds between off/on.
+ 60 wait 60 seconds (1 minute) between off/on.
+
+ If a value other than a supported value is provided in a
+ set request, the MasterSwitch VM interprets it as the next lower
+ acceptable value. If the provided value is lower than
+ the lowest acceptable value, the lowest acceptable
+ value is used."
+ ::= { sPDUOutletConfigVMEntry 7 }
+
+-- the sPDUOutletStatusVM group
+
+sPDUOutletStatusVMTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF OutletStatusVMEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for getting of status of individual outlets. The number of
+ entries is contained in the sPDUMasterStatusOutletCount OID."
+ ::= { sPDUOutletStatusVM 1 }
+
+sPDUOutletStatusVMEntry OBJECT-TYPE
+ SYNTAX OutletStatusVMEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The outlets to gather status from."
+ INDEX { sPDUOutletStatusVMIndex, sPDUOutletStatusVMOutletIndex }
+ ::= { sPDUOutletStatusVMTable 1 }
+
+OutletStatusVMEntry ::=
+ SEQUENCE {
+ sPDUOutletStatusVMIndex INTEGER,
+ sPDUOutletStatusVMName DisplayString,
+ sPDUOutletStatusVMOutletIndex INTEGER,
+ sPDUOutletStatusVMOutletName DisplayString,
+ sPDUOutletStatusVMOutletState INTEGER,
+ sPDUOutletStatusVMCommandPending INTEGER
+ }
+
+sPDUOutletStatusVMIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the MasterSwitch VM."
+ ::= { sPDUOutletStatusVMEntry 1 }
+
+sPDUOutletStatusVMName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The name of the MasterSwitch VM. Maximum size is 23 characters."
+ ::= { sPDUOutletStatusVMEntry 2 }
+
+sPDUOutletStatusVMOutletIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the outlet entry."
+ ::= { sPDUOutletStatusVMEntry 3 }
+
+sPDUOutletStatusVMOutletName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The name of the outlet. Maximum size is 23 characters."
+ ::= { sPDUOutletStatusVMEntry 4 }
+
+sPDUOutletStatusVMOutletState OBJECT-TYPE
+ SYNTAX INTEGER {
+ outletStatusVMOn (1),
+ outletStatusVMOff (2)
+ }
+
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this variable will return the outlet state. If
+ the outlet is on, the outletStatusOnVM (1) value will be returned.
+ If the outlet is off, the outletStatusOffVM (2) value will be
+ returned. "
+ ::= { sPDUOutletStatusVMEntry 5 }
+
+sPDUOutletStatusVMCommandPending OBJECT-TYPE
+ SYNTAX INTEGER {
+ outletStatusVMCommandPending (1),
+ outletStatusVMNoCommandPending (2)
+ }
+
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this variable will return the command pending
+ state of the outlet. If a command is pending on the
+ outlet, the outletStatusVMCommandPending (1) value
+ will be returned. If there is not a command pending
+ on the outlet, the outletStatusVMNoCommandPending (2)
+ will be returned."
+ ::= { sPDUOutletStatusVMEntry 6 }
+
+-- the sPDUIdentMSP group
+
+sPDUIdentMSPTableSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of MasterSwitch pluses controllable
+ by this IP address."
+ ::= { sPDUIdentMSP 1 }
+
+
+sPDUIdentMSPTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF IdentMSPEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for query of the individual MasterSwitch pluses.
+ The number of entries is contained in the
+ sPDUIdentMSPTableSize OID."
+ ::= { sPDUIdentMSP 2 }
+
+sPDUIdentMSPEntry OBJECT-TYPE
+ SYNTAX IdentMSPEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The MasterSwitch pluses to query."
+ INDEX { sPDUIdentMSPIndex}
+ ::= { sPDUIdentMSPTable 1 }
+
+IdentMSPEntry ::=
+ SEQUENCE {
+ sPDUIdentMSPIndex INTEGER,
+ sPDUIdentNameMSP DisplayString,
+ sPDUIdentHardwareRevMSP DisplayString,
+ sPDUIdentFirmwareRevMSP DisplayString,
+ sPDUIdentDateOfManufactureMSP DisplayString,
+ sPDUIdentModelNumberMSP DisplayString,
+ sPDUIdentSerialNumberMSP DisplayString
+ }
+
+sPDUIdentMSPIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the MasterSwitch plus entry."
+ ::= { sPDUIdentMSPEntry 1 }
+
+sPDUIdentNameMSP OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The name of the MasterSwitch plus. The maximum
+ value is 23 characters. The name is set by
+ using the sPDUMasterConfigMSPName OID."
+ ::= { sPDUIdentMSPEntry 2 }
+
+sPDUIdentHardwareRevMSP OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The hardware version of the MasterSwitch plus.
+ This value is set at the factory."
+ ::= { sPDUIdentMSPEntry 3 }
+
+sPDUIdentFirmwareRevMSP OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "An 6-character ID string identifying the MasterSwitch plus
+ firmware version. This value is set at the factory."
+ ::= { sPDUIdentMSPEntry 4 }
+
+sPDUIdentDateOfManufactureMSP OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The date when the MasterSwitch plus was manufactured in mm/dd/yyyy format.
+ This value is set at the factory. "
+ ::= { sPDUIdentMSPEntry 5 }
+
+sPDUIdentModelNumberMSP OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A 17-character string identifying the model number of
+ the MasterSwitch plus. This value is set at the factory."
+ ::= { sPDUIdentMSPEntry 6 }
+
+sPDUIdentSerialNumberMSP OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A 17-character string identifying the serial number of
+ the MasterSwitch plus. This value is set at the factory."
+ ::= { sPDUIdentMSPEntry 7 }
+
+
+-- the sPDUMasterControlMSP group
+
+sPDUMasterControlMSPTableSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of MasterSwitch pluses controllable
+ by this IP address."
+ ::= { sPDUMasterControlMSP 1 }
+
+sPDUMasterControlMSPTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF MasterControlMSPEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for control of the individual MasterSwitch pluses.
+ The number of entries is contained in the
+ sPDUMasterControlMSPTableSize OID."
+ ::= { sPDUMasterControlMSP 2 }
+
+sPDUMasterControlMSPEntry OBJECT-TYPE
+ SYNTAX MasterControlMSPEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The MasterSwitch pluses to control."
+ INDEX { sPDUMasterControlMSPIndex}
+ ::= { sPDUMasterControlMSPTable 1 }
+
+MasterControlMSPEntry ::=
+ SEQUENCE {
+ sPDUMasterControlMSPIndex INTEGER,
+ sPDUMasterControlMSPName DisplayString,
+ sPDUMasterControlMSPCommand INTEGER
+ }
+
+sPDUMasterControlMSPIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the MasterSwitch plus entry."
+ ::= { sPDUMasterControlMSPEntry 1 }
+
+sPDUMasterControlMSPName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The name of the MasterSwitch plus. The maximum
+ value is 23 characters. The name is set by
+ using the sPDUMasterConfigMSPName OID."
+ ::= { sPDUMasterControlMSPEntry 2 }
+
+sPDUMasterControlMSPCommand OBJECT-TYPE
+ SYNTAX INTEGER {
+ noCommandAllMSP (1),
+ immediateAllOnMSP (2),
+ sequencedAllOnMSP (3),
+ immediateAllOffMSP (4),
+ gracefulAllRebootMSP (5),
+ immediateAllRebootMSP (6),
+ gracefulAllShutdownMSP (7),
+ overrideAllBatCapThreshMSP (8),
+ cancelAllPendingCommandsMSP (9),
+ restoreFactoryDefaultsMSP (10)
+ }
+
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Setting this OID to immediateAllOnMSP (2) will turn all outlets
+ on immediately.
+
+ Setting this OID to sequencedAllOnMSP (3) will turn all outlets
+ on as defined by each outlet's sPDUOutletConfigMSPPowerOnDelay OID value.
+
+ Setting this OID to immediateAllOffMSP (4) will turn all outlets
+ off immediately.
+
+ Setting this OID to gracefulAllRebootMSP (5) will reboot all outlets
+ (after the device running PowerChute confirms shutdown) as defined
+ by each outlet's sPDUOutletConfigMSPRebootDuration OID time value.
+
+ Setting this OID to immediateAllRebootMSP (6) will reboot all outlets
+ immediately.
+
+ Setting this OID to gracefulAllShutdownMSP (7) will shutdown all outlets
+ (after the device running PowerChute confirms shutdown) as defined
+ by each outlet's sPDUOutletConfigMSPPowerOffDelay OID time value. Each
+ outlet will then turn on after the sum of its
+ sPDUOutletConfigMSPRestartDelay and sPDUOutletConfigMSPPowerOnDelay OID
+ values.
+
+ Setting this OID to overrideAllBatCapThreshMSP (8) will cause the
+ outlet to ignore the Battery Capacity Threshold and proceed turning on
+ the outlets as defined by each outlet's sPDUOutletConfigMSPPowerOnDelay
+ OID value.
+
+ Setting this OID to cancelAllPendingCommandsMSP (9) will cause all pending
+ commands on the MasterSwitch plus to be canceled.
+
+ Setting this OID to restoreFactoryDefaultsMSP (10) will cause the settings of
+ the MasterSwitch plus to be restored to the factory defaults.
+
+ Getting this OID will return the noCommandAllMSP (1) value."
+ ::= { sPDUMasterControlMSPEntry 3 }
+
+
+-- the sPDUMasterConfigMSP group
+
+sPDUMasterConfigMSPTableSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of MasterSwitch pluses configurable
+ by this IP address."
+ ::= { sPDUMasterConfigMSP 1 }
+
+sPDUMasterConfigMSPTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF MasterConfigMSPEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for configuration of the individual MasterSwitch pluses.
+ The number of entries is contained in the
+ sPDUMasterConfigMSPTableSize OID."
+ ::= { sPDUMasterConfigMSP 2 }
+
+sPDUMasterConfigMSPEntry OBJECT-TYPE
+ SYNTAX MasterConfigMSPEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The MasterSwitch pluses to configure."
+ INDEX { sPDUMasterConfigMSPIndex}
+ ::= { sPDUMasterConfigMSPTable 1 }
+
+MasterConfigMSPEntry ::=
+ SEQUENCE {
+ sPDUMasterConfigMSPIndex INTEGER,
+ sPDUMasterConfigMSPName DisplayString,
+ sPDUMasterConfigMSPPowerOnTimeDelay INTEGER,
+ sPDUMasterConfigMSPManualButton INTEGER
+ }
+
+sPDUMasterConfigMSPIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the MasterSwitch plus entry."
+ ::= { sPDUMasterConfigMSPEntry 1 }
+
+sPDUMasterConfigMSPName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The name of the MasterSwitch plus. Maximum size is 23 characters."
+ ::= { sPDUMasterConfigMSPEntry 2 }
+
+sPDUMasterConfigMSPPowerOnTimeDelay OBJECT-TYPE
+ SYNTAX INTEGER (0..9999)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ " The amount of delay, in seconds, between when
+ power is provided to the MasterSwitch plus and
+ when the MasterSwitch plus provides basic master
+ power to the outlets.
+
+ Allowed values are:
+
+ 0 - 9999 seconds (0 - 2hrs, 46 mins, 39 secs).
+ 0 indicates to apply power immediately."
+ ::= { sPDUMasterConfigMSPEntry 3 }
+
+
+sPDUMasterConfigMSPManualButton OBJECT-TYPE
+ SYNTAX INTEGER {
+ manualButtonDisabled (1),
+ manualButtonEnabled (2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Setting this OID to manualButtonDisabled (1) will disable
+ the manual button on the MasterSwitch plus.
+
+ Setting this OID to manualButtonEnabled (2) will enable
+ the manual button on the MasterSwitch plus."
+ ::= { sPDUMasterConfigMSPEntry 4 }
+
+-- the sPDUMasterStatusMSP group
+
+sPDUMasterStatusMSPTableSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of MasterSwitch pluses at
+ this IP address."
+ ::= { sPDUMasterStatusMSP 1 }
+
+
+sPDUMasterStatusMSPTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF MasterStatusMSPEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for gathering of status from the individual
+ MasterSwitch pluses. The number of entries is contained
+ in the sPDUMasterStatusMSPTableSize OID."
+ ::= { sPDUMasterStatusMSP 2 }
+
+sPDUMasterStatusMSPEntry OBJECT-TYPE
+ SYNTAX MasterStatusMSPEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The MasterSwitch pluses to gather status from."
+ INDEX { sPDUMasterStatusMSPIndex}
+ ::= { sPDUMasterStatusMSPTable 1 }
+
+MasterStatusMSPEntry ::=
+ SEQUENCE {
+ sPDUMasterStatusMSPIndex INTEGER,
+ sPDUMasterStatusMSPName DisplayString,
+ sPDUMasterStatusMSPOutletCount INTEGER
+ }
+
+sPDUMasterStatusMSPIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the MasterSwitch plus entry."
+ ::= { sPDUMasterStatusMSPEntry 1 }
+
+sPDUMasterStatusMSPName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The name of the MasterSwitch plus. The maximum
+ value is 23 characters. The name is set by
+ using the sPDUMasterConfigMSPName OID."
+ ::= { sPDUMasterStatusMSPEntry 2 }
+
+sPDUMasterStatusMSPOutletCount OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this OID will return the number of controllable
+ outlets for this MasterSwitch plus."
+ ::= { sPDUMasterStatusMSPEntry 3 }
+
+-- the sPDUOutletControlMSP group
+
+sPDUOutletControlMSPTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF OutletControlMSPEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for control of individual outlet switches. The number of
+ entries is contained in the sPDUMasterStatusMSPOutletCount OID."
+ ::= { sPDUOutletControlMSP 1 }
+
+sPDUOutletControlMSPEntry OBJECT-TYPE
+ SYNTAX OutletControlMSPEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The outlets to control."
+ INDEX { sPDUOutletControlMSPIndex, sPDUOutletControlMSPOutletIndex }
+ ::= { sPDUOutletControlMSPTable 1 }
+
+OutletControlMSPEntry ::=
+ SEQUENCE {
+ sPDUOutletControlMSPIndex INTEGER,
+ sPDUOutletControlMSPName DisplayString,
+ sPDUOutletControlMSPOutletIndex INTEGER,
+ sPDUOutletControlMSPOutletName DisplayString,
+ sPDUOutletControlMSPOutletCommand INTEGER
+ }
+
+sPDUOutletControlMSPIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the MasterSwitch plus."
+ ::= { sPDUOutletControlMSPEntry 1 }
+
+sPDUOutletControlMSPName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The name of the MasterSwitch plus. The maximum
+ value is 23 characters. The name is set by
+ using the sPDUMasterConfigMSPName OID."
+ ::= { sPDUOutletControlMSPEntry 2 }
+
+sPDUOutletControlMSPOutletIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the outlet entry."
+ ::= { sPDUOutletControlMSPEntry 3 }
+
+sPDUOutletControlMSPOutletName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The name of the outlet. The maximum size is
+ 23 characters. The name is set by using the
+ sPDUOutletConfigMSPallOutletName OID.
+ This OID is provided for informational purposes only."
+ ::= { sPDUOutletControlMSPEntry 4 }
+
+sPDUOutletControlMSPOutletCommand OBJECT-TYPE
+ SYNTAX INTEGER {
+ immediateOnMSP (1),
+ delayedOnMSP (2),
+ immediateOffMSP (3),
+ gracefulRebootMSP (4),
+ immediateRebootMSP (5),
+ gracefulshutdownMSP (6),
+ overrideBatCapThreshMSP (7),
+ cancelPendingCommandMSP (8)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this variable will return the outlet state. If
+ the outlet is on, the immediateOnMSP (1) value will be returned.
+ If the outlet is off, the immediateOffMSP (3) value will be
+ returned.
+
+ Setting this variable to immediateOnMSP (1) will immediately turn the outlet on.
+
+ Setting this variable to delayedOnMSP (2) will turn the outlet on
+ after the sPDUOutletConfigMSPPowerOnDelay OID time has elapsed.
+
+ Setting this variable to immediateOffMSP (3) will immediately turn the outlet off.
+
+ Setting this variable to gracefulRebootMSP (4) will cause the outlet to wait for
+ device confirmation (if applicable) and then turn the outlet off after the
+ sPDUOutletConfigMSPPowerOffDelay OID time has elapsed. The outlet will then turn
+ on after the sPDUOutletConfigMSPRebootDuration OID time has elapsed.
+
+ Setting this variable to immediateRebootMSP (5) will immediately reboot the outlet.
+
+ Setting this variable to gracefulshutdownMSP (6) will cause the outlet to wait for
+ device confirmation (if applicable) and then turn the outlet off after the
+ sPDUOutletConfigMSPPowerOffDelay OID time has elapsed. The outlet will then turn
+ on after the sum of the sPDUOutletConfigMSPRestartTime OID time and the
+ sPDUOutletConfigMSPPowerOnDelay OID time has elapsed.
+
+ Setting this variable to overrideBatCapThreshMSP (7) will cause the outlet to
+ ignore the Battery Capacity Threshold and proceed waiting on the
+ sPDUOutletConfigMSPPowerOnDelay OID time before turning the outlet on.
+
+ Setting this variable to cancelPendingCommandMSP (8) will cause any
+ pending command to this outlet to be canceled."
+ ::= { sPDUOutletControlMSPEntry 5 }
+
+-- the sPDUOutletConfigMSPall group
+
+sPDUOutletConfigMSPallTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF OutletConfigMSPallEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for configuration of individual outlets. The number of
+ entries is contained in the sPDUMasterStatusMSPOutletCount OID."
+ ::= { sPDUOutletConfigMSPall 1 }
+
+sPDUOutletConfigMSPallEntry OBJECT-TYPE
+ SYNTAX OutletConfigMSPallEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The outlets to configure."
+ INDEX { sPDUOutletConfigMSPallIndex, sPDUOutletConfigMSPallOutletIndex }
+ ::= { sPDUOutletConfigMSPallTable 1 }
+
+OutletConfigMSPallEntry ::=
+ SEQUENCE {
+ sPDUOutletConfigMSPallIndex INTEGER,
+ sPDUOutletConfigMSPallName DisplayString,
+ sPDUOutletConfigMSPallOutletIndex INTEGER,
+ sPDUOutletConfigMSPallOutletName DisplayString,
+ sPDUOutletConfigMSPallOutletCtrlMode INTEGER
+ }
+
+sPDUOutletConfigMSPallIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the MasterSwitch plus."
+ ::= { sPDUOutletConfigMSPallEntry 1 }
+
+sPDUOutletConfigMSPallName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The name of the MasterSwitch plus. The maximum
+ value is 23 characters. The name is set by
+ using the sPDUMasterConfigMSPName OID."
+ ::= { sPDUOutletConfigMSPallEntry 2 }
+
+sPDUOutletConfigMSPallOutletIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the outlet entry."
+ ::= { sPDUOutletConfigMSPallEntry 3 }
+
+sPDUOutletConfigMSPallOutletName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The name of the outlet. Maximum size is 23 characters."
+ ::= { sPDUOutletConfigMSPallEntry 4 }
+
+sPDUOutletConfigMSPallOutletCtrlMode OBJECT-TYPE
+ SYNTAX INTEGER {
+ modeGracefulShutdown (1),
+ modeAnnunciator (2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Setting this OID to modeGracefulShutdown (1) will put this
+ outlet into the Graceful Shutdown control mode.
+
+ Setting this OID to modeAnnunciator (2) will put this outlet
+ into the Annunciator control mode."
+ ::= { sPDUOutletConfigMSPallEntry 5 }
+
+
+-- the sPDUOutConfigMSPgs group
+
+sPDUOutletConfigMSPgsTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF OutletConfigMSPgsEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for configuration of individual outlets. The number of
+ entries is contained in the sPDUMasterStatusMSPOutletCount OID."
+ ::= { sPDUOutletConfigMSPgs 1 }
+
+sPDUOutletConfigMSPgsEntry OBJECT-TYPE
+ SYNTAX OutletConfigMSPgsEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The outlets to configure."
+ INDEX { sPDUOutletConfigMSPgsIndex, sPDUOutletConfigMSPgsOutletIndex }
+ ::= { sPDUOutletConfigMSPgsTable 1 }
+
+OutletConfigMSPgsEntry ::=
+ SEQUENCE {
+ sPDUOutletConfigMSPgsIndex INTEGER,
+ sPDUOutletConfigMSPgsName DisplayString,
+ sPDUOutletConfigMSPgsOutletIndex INTEGER,
+ sPDUOutletConfigMSPgsOutletName DisplayString,
+ sPDUOutletConfigMSPgsOutletCtrlMode INTEGER,
+ sPDUOutletConfigMSPgsDeviceConfirm INTEGER,
+ sPDUOutletConfigMSPgsLowBattWarning INTEGER,
+ sPDUOutletConfigMSPgsLowBattMult INTEGER,
+ sPDUOutletConfigMSPgsRestartDelay INTEGER,
+ sPDUOutletConfigMSPgsPowerOnDelay INTEGER,
+ sPDUOutletConfigMSPgsPowerOffDelay INTEGER,
+ sPDUOutletConfigMSPgsBattCapThresh INTEGER,
+ sPDUOutletConfigMSPgsRebootDuration INTEGER
+ }
+
+sPDUOutletConfigMSPgsIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the MasterSwitch plus."
+ ::= { sPDUOutletConfigMSPgsEntry 1 }
+
+sPDUOutletConfigMSPgsName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The name of the MasterSwitch plus. The maximum
+ value is 23 characters. The name is set by
+ using the sPDUMasterConfigMSPName OID."
+ ::= { sPDUOutletConfigMSPgsEntry 2 }
+
+sPDUOutletConfigMSPgsOutletIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the outlet entry."
+ ::= { sPDUOutletConfigMSPgsEntry 3 }
+
+sPDUOutletConfigMSPgsOutletName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The name of the outlet. The maximum size is
+ 23 characters. The name is set by using the
+ sPDUOutletConfigMSPallOutletName OID.
+ This OID is provided for informational purposes only."
+ ::= { sPDUOutletConfigMSPgsEntry 4 }
+
+sPDUOutletConfigMSPgsOutletCtrlMode OBJECT-TYPE
+ SYNTAX INTEGER {
+ modeGracefulShutdown (1),
+ modeAnnunciator (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The Control Mode of the outlet.
+ This OID is provided for informational purposes only."
+ ::= { sPDUOutletConfigMSPgsEntry 5 }
+
+sPDUOutletConfigMSPgsDeviceConfirm OBJECT-TYPE
+ SYNTAX INTEGER {
+ deviceConfirmNo (1),
+ deviceConfirmYes (2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Setting this OID to deviceConfirmNo (1) cause the outlet to
+ NOT wait for device confirmation while performing graceful
+ operations.
+
+ Setting this OID to deviceConfirmYes (2) cause the outlet to
+ wait for device confirmation while performing graceful
+ operations."
+ ::= { sPDUOutletConfigMSPgsEntry 6 }
+
+sPDUOutletConfigMSPgsLowBattWarning OBJECT-TYPE
+ SYNTAX INTEGER (-2..9999)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ " The amount of delay, in 6 second intervals, between
+ when the UPS goes on battery and the power down sequence for
+ the outlet is initiated.
+
+ Allowed values are:
+
+ -2 - Never initiate the power down sequence on low battery warning.
+ -1 - Initiate power down sequence based on remaining runtime.
+ 1 - 9999 six second intervals (6 secs - 16hrs, 39 mins, 54 secs).
+ 0 indicates to immediately initiate power down sequence on low
+ battery warning."
+ ::= { sPDUOutletConfigMSPgsEntry 7 }
+
+sPDUOutletConfigMSPgsLowBattMult OBJECT-TYPE
+ SYNTAX INTEGER (1..7)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ " Only applicable if sPDUOutletConfigMSPgsLowBattWarning OID is
+ set to -1 (On Runtime Remaining).
+
+ Allows you to set the value to stagger the shutdown sequence of the outlets.
+ 1 provides the longest delay (the outlet to shutoff first), and 7 would
+ provide the shortest delay (the outlet to shut off last).
+
+ Allowed values are:
+ 1 - 7."
+ ::= { sPDUOutletConfigMSPgsEntry 8 }
+
+sPDUOutletConfigMSPgsRestartDelay OBJECT-TYPE
+ SYNTAX INTEGER (-1..9999)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ " The amount of delay, in 6 minute intervals, between
+ when the outlet is turned off and the outlet is turned back on
+ when performing a Graceful Shutdown.
+
+ Allowed values are:
+
+ -1 - Never turn outlet back on after a Graceful shutdown.
+ 0 - 9999 six minute intervals (0 - 999hrs, 54 mins)."
+ ::= { sPDUOutletConfigMSPgsEntry 9 }
+
+sPDUOutletConfigMSPgsPowerOnDelay OBJECT-TYPE
+ SYNTAX INTEGER (-1..9999)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ " The amount of delay, in seconds, between the UPS entering
+ normal (on-line) state and the outlet being powered on.
+
+ Allowed values are:
+
+ -1 - Remain Off when the UPS enters the on-line state.
+ 0 - 9999 seconds (0 - 2 hrs, 46 mins, 39 secs)."
+ ::= { sPDUOutletConfigMSPgsEntry 10 }
+
+
+sPDUOutletConfigMSPgsPowerOffDelay OBJECT-TYPE
+ SYNTAX INTEGER (0..9999)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ " The amount of delay, in seconds, between when the server
+ shuts down and the outlet is powered off.
+
+ Allowed values are:
+
+ 0 - 9999 seconds (0 - 2 hrs, 46 mins, 39 secs)."
+ ::= { sPDUOutletConfigMSPgsEntry 11 }
+
+sPDUOutletConfigMSPgsBattCapThresh OBJECT-TYPE
+ SYNTAX INTEGER (0..100)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ " The minimum battery capacity, as a percent (0-100%), required
+ of the UPS before an outlet will be allowed to power on.
+
+ Allowed values are:
+
+ 0 - 100 percent."
+ ::= { sPDUOutletConfigMSPgsEntry 12 }
+
+sPDUOutletConfigMSPgsRebootDuration OBJECT-TYPE
+ SYNTAX INTEGER (0..9999)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ " The amount of delay, in seconds, from outlet off until
+ outlet on during a reboot.
+
+ Allowed values are:
+
+ 0 - 9999 seconds (0 - 2 hrs, 46 mins, 39 secs)."
+ ::= { sPDUOutletConfigMSPgsEntry 13 }
+
+
+-- the sPDUOutConfigMSPannun group
+
+sPDUOutletConfigMSPannunTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF OutletConfigMSPannunEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for configuration of individual outlets. The number of
+ entries is contained in the sPDUMasterStatusMSPOutletCount OID."
+ ::= { sPDUOutletConfigMSPannun 1 }
+
+sPDUOutletConfigMSPannunEntry OBJECT-TYPE
+ SYNTAX OutletConfigMSPannunEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The outlets to configure."
+ INDEX { sPDUOutletConfigMSPannunIndex, sPDUOutletConfigMSPannunOutletIndex }
+ ::= { sPDUOutletConfigMSPannunTable 1 }
+
+OutletConfigMSPannunEntry ::=
+ SEQUENCE {
+ sPDUOutletConfigMSPannunIndex INTEGER,
+ sPDUOutletConfigMSPannunName DisplayString,
+ sPDUOutletConfigMSPannunOutletIndex INTEGER,
+ sPDUOutletConfigMSPannunOutletName DisplayString,
+ sPDUOutletConfigMSPannunOutletCtrlMode INTEGER,
+ sPDUOutletConfigMSPannunInitialState INTEGER,
+ sPDUOutletConfigMSPannunAlarmActionDly INTEGER
+ }
+
+sPDUOutletConfigMSPannunIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the MasterSwitch plus."
+ ::= { sPDUOutletConfigMSPannunEntry 1 }
+
+sPDUOutletConfigMSPannunName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The name of the MasterSwitch plus. The maximum
+ value is 23 characters. The name is set by
+ using the sPDUMasterConfigMSPName OID."
+ ::= { sPDUOutletConfigMSPannunEntry 2 }
+
+sPDUOutletConfigMSPannunOutletIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the outlet entry."
+ ::= { sPDUOutletConfigMSPannunEntry 3 }
+
+sPDUOutletConfigMSPannunOutletName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The name of the outlet. The maximum size is
+ 23 characters. The name is set by using the
+ sPDUOutletConfigMSPallOutletName OID.
+ This OID is provided for informational purposes only."
+ ::= { sPDUOutletConfigMSPannunEntry 4 }
+
+sPDUOutletConfigMSPannunOutletCtrlMode OBJECT-TYPE
+ SYNTAX INTEGER {
+ modeGracefulShutdown (1),
+ modeAnnunciator (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The Control Mode of the outlet.
+ This OID is provided for informational purposes only."
+ ::= { sPDUOutletConfigMSPannunEntry 5 }
+
+sPDUOutletConfigMSPannunInitialState OBJECT-TYPE
+ SYNTAX INTEGER {
+ initialStateOff (1),
+ initialStateOn (2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Setting this OID to initialStateOff (1) causes the outlet
+ to default to off when in the non-alarmed condition.
+
+ Setting this OID to initialStateOn (2) causes the outlet
+ to default to on when in the non-alarmed condition."
+ ::= { sPDUOutletConfigMSPannunEntry 6 }
+
+sPDUOutletConfigMSPannunAlarmActionDly OBJECT-TYPE
+ SYNTAX INTEGER (0..9999)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ " The amount of time, in seconds, that an enabled Measure-UPS
+ alarm must be asserted before an alarm condition is recognized.
+
+ Allowed values are:
+
+ 0 - 9999 seconds (0 - 2 hrs, 46 mins, 39 secs)."
+ ::= { sPDUOutletConfigMSPannunEntry 7 }
+
+
+-- the sPDUOutConfigMSPmups group
+
+sPDUOutletConfigMSPmupsTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF OutletConfigMSPmupsEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for configuration of individual outlets. The number of
+ entries is contained in the sPDUMasterStatusMSPOutletCount OID."
+ ::= { sPDUOutletConfigMSPmups 1 }
+
+sPDUOutletConfigMSPmupsEntry OBJECT-TYPE
+ SYNTAX OutletConfigMSPmupsEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The outlets to configure."
+ INDEX { sPDUOutletConfigMSPmupsIndex, sPDUOutletConfigMSPmupsOutletIndex }
+ ::= { sPDUOutletConfigMSPmupsTable 1 }
+
+OutletConfigMSPmupsEntry ::=
+ SEQUENCE {
+ sPDUOutletConfigMSPmupsIndex INTEGER,
+ sPDUOutletConfigMSPmupsName DisplayString,
+ sPDUOutletConfigMSPmupsOutletIndex INTEGER,
+ sPDUOutletConfigMSPmupsOutletName DisplayString,
+ sPDUOutletConfigMSPmupsZone1 INTEGER,
+ sPDUOutletConfigMSPmupsZone2 INTEGER,
+ sPDUOutletConfigMSPmupsZone3 INTEGER,
+ sPDUOutletConfigMSPmupsZone4 INTEGER,
+ sPDUOutletConfigMSPmupsP1LowHum INTEGER,
+ sPDUOutletConfigMSPmupsP1HiHum INTEGER,
+ sPDUOutletConfigMSPmupsP1LowTemp INTEGER,
+ sPDUOutletConfigMSPmupsP1HiTemp INTEGER,
+ sPDUOutletConfigMSPmupsP2LowHum INTEGER,
+ sPDUOutletConfigMSPmupsP2HiHum INTEGER,
+ sPDUOutletConfigMSPmupsP2LowTemp INTEGER,
+ sPDUOutletConfigMSPmupsP2HiTemp INTEGER
+ }
+
+sPDUOutletConfigMSPmupsIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the MasterSwitch plus."
+ ::= { sPDUOutletConfigMSPmupsEntry 1 }
+
+sPDUOutletConfigMSPmupsName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The name of the MasterSwitch plus. The maximum
+ value is 23 characters. The name is set by
+ using the sPDUMasterConfigMSPName OID."
+ ::= { sPDUOutletConfigMSPmupsEntry 2 }
+
+sPDUOutletConfigMSPmupsOutletIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the outlet entry."
+ ::= { sPDUOutletConfigMSPmupsEntry 3 }
+
+sPDUOutletConfigMSPmupsOutletName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The name of the outlet. The maximum size is
+ 23 characters. The name is set by using the
+ sPDUOutletConfigMSPallOutletName OID.
+ This OID is provided for informational purposes only."
+ ::= { sPDUOutletConfigMSPmupsEntry 4 }
+
+sPDUOutletConfigMSPmupsZone1 OBJECT-TYPE
+ SYNTAX INTEGER {
+ disableAlarm (1),
+ enableAlarm (2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Setting this OID to disableAlarm (1) disables the
+ Zone 1 alarm for this outlet.
+
+ Setting this OID to enableAlarm (2) enables the
+ Zone 1 alarm for this outlet."
+ ::= { sPDUOutletConfigMSPmupsEntry 5 }
+
+sPDUOutletConfigMSPmupsZone2 OBJECT-TYPE
+ SYNTAX INTEGER {
+ disableAlarm (1),
+ enableAlarm (2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Setting this OID to disableAlarm (1) disables the
+ Zone 2 alarm for this outlet.
+
+ Setting this OID to enableAlarm (2) enables the
+ Zone 2 alarm for this outlet."
+ ::= { sPDUOutletConfigMSPmupsEntry 6 }
+
+sPDUOutletConfigMSPmupsZone3 OBJECT-TYPE
+ SYNTAX INTEGER {
+ disableAlarm (1),
+ enableAlarm (2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Setting this OID to disableAlarm (1) disables the
+ Zone 3 alarm for this outlet.
+
+ Setting this OID to enableAlarm (2) enables the
+ Zone 3 alarm for this outlet."
+ ::= { sPDUOutletConfigMSPmupsEntry 7 }
+
+sPDUOutletConfigMSPmupsZone4 OBJECT-TYPE
+ SYNTAX INTEGER {
+ disableAlarm (1),
+ enableAlarm (2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Setting this OID to disableAlarm (1) disables the
+ Zone 4 alarm for this outlet.
+
+ Setting this OID to enableAlarm (2) enables the
+ Zone 4 alarm for this outlet."
+ ::= { sPDUOutletConfigMSPmupsEntry 8 }
+
+sPDUOutletConfigMSPmupsP1LowHum OBJECT-TYPE
+ SYNTAX INTEGER {
+ disableAlarm (1),
+ enableAlarm (2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Setting this OID to disableAlarm (1) disables the
+ Probe 1 low humidity alarm for this outlet.
+
+ Setting this OID to enableAlarm (2) enables the
+ Probe 1 low humidity alarm for this outlet."
+ ::= { sPDUOutletConfigMSPmupsEntry 9 }
+
+sPDUOutletConfigMSPmupsP1HiHum OBJECT-TYPE
+ SYNTAX INTEGER {
+ disableAlarm (1),
+ enableAlarm (2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Setting this OID to disableAlarm (1) disables the
+ Probe 1 high humidity alarm for this outlet.
+
+ Setting this OID to enableAlarm (2) enables the
+ Probe 1 high humidity alarm for this outlet."
+ ::= { sPDUOutletConfigMSPmupsEntry 10 }
+
+sPDUOutletConfigMSPmupsP1LowTemp OBJECT-TYPE
+ SYNTAX INTEGER {
+ disableAlarm (1),
+ enableAlarm (2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Setting this OID to disableAlarm (1) disables the
+ Probe 1 low temperature alarm for this outlet.
+
+ Setting this OID to enableAlarm (2) enables the
+ Probe 1 low temperature alarm for this outlet."
+ ::= { sPDUOutletConfigMSPmupsEntry 11 }
+
+sPDUOutletConfigMSPmupsP1HiTemp OBJECT-TYPE
+ SYNTAX INTEGER {
+ disableAlarm (1),
+ enableAlarm (2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Setting this OID to disableAlarm (1) disables the
+ Probe 1 high temperature alarm for this outlet.
+
+ Setting this OID to enableAlarm (2) enables the
+ Probe 1 high temperature alarm for this outlet."
+ ::= { sPDUOutletConfigMSPmupsEntry 12 }
+
+sPDUOutletConfigMSPmupsP2LowHum OBJECT-TYPE
+ SYNTAX INTEGER {
+ disableAlarm (1),
+ enableAlarm (2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Setting this OID to disableAlarm (1) disables the
+ Probe 2 low humidity alarm for this outlet.
+
+ Setting this OID to enableAlarm (2) enables the
+ Probe 2 low humidity alarm for this outlet."
+ ::= { sPDUOutletConfigMSPmupsEntry 13 }
+
+sPDUOutletConfigMSPmupsP2HiHum OBJECT-TYPE
+ SYNTAX INTEGER {
+ disableAlarm (1),
+ enableAlarm (2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Setting this OID to disableAlarm (1) disables the
+ Probe 2 high humidity alarm for this outlet.
+
+ Setting this OID to enableAlarm (2) enables the
+ Probe 2 high humidity alarm for this outlet."
+ ::= { sPDUOutletConfigMSPmupsEntry 14 }
+
+sPDUOutletConfigMSPmupsP2LowTemp OBJECT-TYPE
+ SYNTAX INTEGER {
+ disableAlarm (1),
+ enableAlarm (2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Setting this OID to disableAlarm (1) disables the
+ Probe 2 low temperature alarm for this outlet.
+
+ Setting this OID to enableAlarm (2) enables the
+ Probe 2 low temperature alarm for this outlet."
+ ::= { sPDUOutletConfigMSPmupsEntry 15 }
+
+sPDUOutletConfigMSPmupsP2HiTemp OBJECT-TYPE
+ SYNTAX INTEGER {
+ disableAlarm (1),
+ enableAlarm (2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Setting this OID to disableAlarm (1) disables the
+ Probe 2 high temperature alarm for this outlet.
+
+ Setting this OID to enableAlarm (2) enables the
+ Probe 2 high temperature alarm for this outlet."
+ ::= { sPDUOutletConfigMSPmupsEntry 16 }
+
+-- the sPDUOutletStatusMSP group
+
+sPDUOutletStatusMSPTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF OutletStatusMSPEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for getting of status of individual outlets. The number of
+ entries is contained in the sPDUMasterStatusOutletCount OID."
+ ::= { sPDUOutletStatusMSP 1 }
+
+sPDUOutletStatusMSPEntry OBJECT-TYPE
+ SYNTAX OutletStatusMSPEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The outlets to gather status from."
+ INDEX { sPDUOutletStatusMSPIndex, sPDUOutletStatusMSPOutletIndex }
+ ::= { sPDUOutletStatusMSPTable 1 }
+
+OutletStatusMSPEntry ::=
+ SEQUENCE {
+ sPDUOutletStatusMSPIndex INTEGER,
+ sPDUOutletStatusMSPName DisplayString,
+ sPDUOutletStatusMSPOutletIndex INTEGER,
+ sPDUOutletStatusMSPOutletName DisplayString,
+ sPDUOutletStatusMSPOutletState INTEGER,
+ sPDUOutletStatusMSPCommandPending INTEGER,
+ sPDUOutletStatusMSPOutletCtrlMode INTEGER
+ }
+
+sPDUOutletStatusMSPIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the MasterSwitch MSP."
+ ::= { sPDUOutletStatusMSPEntry 1 }
+
+sPDUOutletStatusMSPName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The name of the MasterSwitch plus. The maximum
+ value is 23 characters. The name is set by
+ using the sPDUMasterConfigMSPName OID."
+ ::= { sPDUOutletStatusMSPEntry 2 }
+
+sPDUOutletStatusMSPOutletIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the outlet entry."
+ ::= { sPDUOutletStatusMSPEntry 3 }
+
+sPDUOutletStatusMSPOutletName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The name of the outlet. The maximum size is
+ 23 characters. The name is set by using the
+ sPDUOutletConfigMSPallOutletName OID.
+ This OID is provided for informational purposes only."
+ ::= { sPDUOutletStatusMSPEntry 4 }
+
+sPDUOutletStatusMSPOutletState OBJECT-TYPE
+ SYNTAX INTEGER {
+ outletStatusMSPOn (1),
+ outletStatusMSPOff (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this variable will return the outlet state. If
+ the outlet is on, the outletStatusMSPOn (1) value will be returned.
+ If the outlet is off, the outletStatusMSPOff (2) value will be
+ returned. "
+ ::= { sPDUOutletStatusMSPEntry 5 }
+
+sPDUOutletStatusMSPCommandPending OBJECT-TYPE
+ SYNTAX INTEGER {
+ outletStatusMSPCommandPending (1),
+ outletStatusMSPNoCommandPending (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this variable will return the command pending
+ state of the outlet. If a command is pending on the
+ outlet, the outletStatusMSPCommandPending (1) value
+ will be returned. If there is not a command pending
+ on the outlet, the outletStatusMSPNoCommandPending (2)
+ will be returned."
+ ::= { sPDUOutletStatusMSPEntry 6 }
+
+sPDUOutletStatusMSPOutletCtrlMode OBJECT-TYPE
+ SYNTAX INTEGER {
+ modeGracefulShutdown (1),
+ modeAnnunciator (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The Control Mode of the outlet.
+ This OID is provided for informational purposes only."
+ ::= { sPDUOutletStatusMSPEntry 7 }
+
+
+-- the rPDUIdent group
+
+rPDUIdentName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The name of the Rack PDU.
+ The maximum string size is device dependent."
+ ::= { rPDUIdent 1 }
+
+rPDUIdentHardwareRev OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The hardware revision of the Rack PDU.
+ This value is set at the factory."
+ ::= { rPDUIdent 2 }
+
+rPDUIdentFirmwareRev OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "An 8-byte ID string identifying the Rack PDU firmware revision.
+ This value is set at the factory."
+ ::= { rPDUIdent 3 }
+
+
+rPDUIdentDateOfManufacture OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The date when the Rack PDU was manufactured in mm/dd/yy format.
+ This value is set at the factory. The year 2000 will be
+ represented by 00."
+ ::= { rPDUIdent 4 }
+
+rPDUIdentModelNumber OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A 10-character string identifying the model number of
+ the Rack PDU. This value is set at the factory."
+ ::= { rPDUIdent 5 }
+
+rPDUIdentSerialNumber OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A 12-character string identifying the serial number of
+ the Rack PDU. This value is set at the factory."
+ ::= { rPDUIdent 6 }
+
+rPDUIdentDeviceRating OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this OID will return the electrical rating of the device."
+
+ ::= { rPDUIdent 7 }
+
+rPDUIdentDeviceNumOutlets OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this OID will return the number of outlets contained in the device."
+
+ ::= { rPDUIdent 8 }
+
+rPDUIdentDeviceNumPhases OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this OID will return the number of phases supported by the device."
+
+ ::= { rPDUIdent 9 }
+
+rPDUIdentDeviceNumBreakers OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this OID will return the number of circuit breakers supported by the device.
+ This is the same as the number of banks of outlets."
+
+ ::= { rPDUIdent 10 }
+
+rPDUIdentDeviceBreakerRating OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this OID will return rating of the circuit breakers on the device if it has any."
+
+ ::= { rPDUIdent 11 }
+
+rPDUIdentDeviceOrientation OBJECT-TYPE
+ SYNTAX INTEGER {
+ orientHorizontal (1),
+ orientVertical (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this OID will return the intended physical orientation of the device.
+
+ OrientHorizonatal(1) indicates Horizontal.
+ OrientVertical(2) indicates Vertical."
+
+ ::= { rPDUIdent 12 }
+
+rPDUIdentDeviceOutletLayout OBJECT-TYPE
+ SYNTAX INTEGER {
+ seqPhaseToNeutral (1),
+ seqPhaseToPhase (2),
+ seqPhToNeu21PhToPh (3),
+ seqPhToPhGrouped (4)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this OID will return outlet layout for the device.
+
+ SeqPhaseToNeutral(1) indicates outlet layout as follows:
+ 1:1-N,2:2-N,3:3-N,4:1-N,5:2-N,...
+
+ SeqPhaseToPhase(2) indicates outlet layout as follows:
+ 1:1-2,2:2-3,3:3-1,4:1-2,5:2-3,...
+
+ SeqPhToNeu21PhToPh(3) indicates outlet layout as follows:
+ 1:1-N,2:2-N...21:3-N,22:1-2,23:2-3,24:3-1,...
+
+ SeqPhToPhGrouped(4) indicates outlet layout as follows:
+ Otlts1-8::(3-1),Otlts9-16::(2-3),Otlts17-24::(1-2)."
+ ::= { rPDUIdent 13 }
+
+
+
+-- the rPDULoadDevice group
+
+rPDULoadDevMaxPhaseLoad OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this OID will return the maximum rated power
+ that each phase of the Rack PDU can provide. It is
+ represented in Amps."
+ ::= { rPDULoadDevice 1 }
+
+rPDULoadDevNumPhases OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of phases available with this Rack PDU."
+ ::= { rPDULoadDevice 2 }
+
+rPDULoadDevMaxBankLoad OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this OID will return the maximum rated power
+ that each bank of the Rack PDU can provide. It is
+ represented in Amps.
+
+ 0 will be returned if the device does not have any banks."
+
+ ::= { rPDULoadDevice 3 }
+
+rPDULoadDevNumBanks OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of banks of outlets available with this Rack PDU.
+ A bank of outlets has a unique circuit breaker for a subset
+ of the total number of outlets on the rPDU."
+ ::= { rPDULoadDevice 4 }
+
+-- the rPDULoadPhaseConfig group
+
+rPDULoadPhaseConfigTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF LoadPhaseConfigEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for configuration of each Rack PDU phase.
+ The number of entries is contained in the
+ rPDULoadDevNumPhases OID."
+ ::= { rPDULoadPhaseConfig 1 }
+
+rPDULoadPhaseConfigEntry OBJECT-TYPE
+ SYNTAX LoadPhaseConfigEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The Rack PDU phase to configure."
+ INDEX { rPDULoadPhaseConfigIndex}
+ ::= { rPDULoadPhaseConfigTable 1 }
+
+LoadPhaseConfigEntry ::=
+ SEQUENCE {
+ rPDULoadPhaseConfigIndex INTEGER,
+ rPDULoadPhaseConfigLowLoadThreshold INTEGER,
+ rPDULoadPhaseConfigNearOverloadThreshold INTEGER,
+ rPDULoadPhaseConfigOverloadThreshold INTEGER
+ }
+
+rPDULoadPhaseConfigIndex OBJECT-TYPE
+ SYNTAX INTEGER {
+ phase1 (1),
+ phase2 (2),
+ phase3 (3)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the Rack PDU phase entry."
+ ::= { rPDULoadPhaseConfigEntry 1 }
+
+rPDULoadPhaseConfigLowLoadThreshold OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "A threshold that indicates the power consumption of
+ the load is nearing a low consumption condition. It is
+ represented in amps. A warning will be issued when the
+ load is less than the threshold value.
+
+ A threshold value of 0 amps effectively disables this
+ warning.
+
+ Maximum value must be less than the value returned
+ by the rPDULoadPhaseConfigNearOverloadThreshold OID."
+ ::= { rPDULoadPhaseConfigEntry 2 }
+
+rPDULoadPhaseConfigNearOverloadThreshold OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "A threshold that indicates the power consumption of
+ the load is nearing an overload condition. It is
+ represented in amps. A warning will be issued when the
+ load is greater than or equal to the threshold value.
+
+ Minimum value must be greater than the value returned by
+ the rPDULoadPhaseConfigLowLoadThreshold OID.
+
+ Maximum value must be less than or equal to the value
+ returned by the rPDULoadPhaseConfigOverloadThreshold OID."
+ ::= { rPDULoadPhaseConfigEntry 3 }
+
+rPDULoadPhaseConfigOverloadThreshold OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "A threshold that indicates the power consumption of
+ the load has entered an overload condition. It is
+ represented in amps. A warning will be issued when the
+ load is greater than or equal to the threshold value.
+
+ Minimum value must be greater than or equal to the value
+ returned by the rPDULoadPhaseConfigNearOverloadThreshold OID.
+
+ Maximum value must be less than or equal to the value
+ returned by the rPDULoadDevMaxPhaseLoad OID."
+ ::= { rPDULoadPhaseConfigEntry 4 }
+
+
+-- the rPDULoadStatus group
+
+rPDULoadStatusTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF LoadStatusEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for getting of status of each Rack PDU phase/bank.
+ The number of entries is calculated by adding
+ the number of phases (rPDULoadDevNumPhases OID) and
+ the number of banks of outlets (rPDULoadDevNumBanks)
+ Number of entries = #phases + #banks.
+ NOTE: If a device has phase and bank information, all phase information
+ shall preceed the bank information."
+ ::= { rPDULoadStatus 1 }
+
+rPDULoadStatusEntry OBJECT-TYPE
+ SYNTAX LoadStatusEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The Rack PDU phase/bank to gather status from."
+ INDEX { rPDULoadStatusIndex}
+ ::= { rPDULoadStatusTable 1 }
+
+LoadStatusEntry ::=
+ SEQUENCE {
+ rPDULoadStatusIndex INTEGER,
+ rPDULoadStatusLoad Gauge,
+ rPDULoadStatusLoadState INTEGER,
+ rPDULoadStatusPhaseNumber INTEGER,
+ rPDULoadStatusBankNumber INTEGER
+ }
+
+rPDULoadStatusIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the Rack PDU phase/bank entry. All phase information will preceed
+ any bank information"
+ ::= { rPDULoadStatusEntry 1 }
+
+rPDULoadStatusLoad OBJECT-TYPE
+ SYNTAX Gauge
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this OID will return the phase/bank load measured
+ in tenths of amps."
+ ::= { rPDULoadStatusEntry 2 }
+
+rPDULoadStatusLoadState OBJECT-TYPE
+ SYNTAX INTEGER {
+ phaseLoadNormal (1),
+ phaseLoadLow (2),
+ phaseLoadNearOverload (3),
+ phaseLoadOverload (4)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this OID will return the phase/bank load state.
+
+ phaseLoadNormal(1) indicates that the phase/bank is
+ operating properly within the rPDULoadConfigLowLoadThreshold
+ and rPDULoadConfigNearOverloadThreshold OID values.
+
+ phaseLoadLow(2) indicates that the phase/bank load has
+ dropped below the rPDULoadConfigLowLoadThreshold OID value.
+ An SNMP trap will occur when this state is entered or cleared.
+
+ phaseLoadNearOverload(3) indicates that the phase/bank load
+ is greater than or equal to the
+ rPDULoadConfigNearOverloadThreshold OID value.
+ An SNMP trap will occur when this state is entered or cleared.
+
+ phaseLoadOverload(4) indicates that the phase/bank load is
+ greater than or equal to the rPDULoadConfigOverloadThreshold
+ OID value.
+ An SNMP trap will occur when this state is entered or cleared."
+ ::= { rPDULoadStatusEntry 3 }
+
+rPDULoadStatusPhaseNumber OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The phase number to which this record refers. A value of 0 will be returned if
+ this is bank related information."
+ ::= { rPDULoadStatusEntry 4 }
+
+rPDULoadStatusBankNumber OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The bank number to which this record refers. A value of 0 will be returned if
+ this is phase related information."
+ ::= { rPDULoadStatusEntry 5 }
+
+-- the rPDULoadBankConfig group
+
+rPDULoadBankConfigTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF LoadBankConfigEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for configuration of each Rack PDU bank.
+ The number of entries is contained in the
+ rPDULoadDevNumBanks OID."
+ ::= { rPDULoadBankConfig 1 }
+
+rPDULoadBankConfigEntry OBJECT-TYPE
+ SYNTAX LoadBankConfigEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The Rack PDU bank to configure."
+ INDEX { rPDULoadBankConfigIndex}
+ ::= { rPDULoadBankConfigTable 1 }
+
+LoadBankConfigEntry ::=
+ SEQUENCE {
+ rPDULoadBankConfigIndex INTEGER,
+ rPDULoadBankConfigLowLoadThreshold INTEGER,
+ rPDULoadBankConfigNearOverloadThreshold INTEGER,
+ rPDULoadBankConfigOverloadThreshold INTEGER
+ }
+
+rPDULoadBankConfigIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the Rack PDU bank entry."
+ ::= { rPDULoadBankConfigEntry 1 }
+
+rPDULoadBankConfigLowLoadThreshold OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "A threshold that indicates the power consumption of
+ the load is nearing a low consumption condition. It is
+ represented in amps. A warning will be issued when the
+ load is less than the threshold value.
+
+ A threshold value of 0 amps effectively disables this
+ warning.
+
+ Maximum value must be less than the value returned
+ by the rPDULoadBankConfigNearOverloadThreshold OID.
+
+ -1 will be returned if the device has no banks."
+
+ ::= { rPDULoadBankConfigEntry 2 }
+
+rPDULoadBankConfigNearOverloadThreshold OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "A threshold that indicates the power consumption of
+ the load is nearing an overload condition. It is
+ represented in amps. A warning will be issued when the
+ load is greater than or equal to the threshold value.
+
+ Minimum value must be greater than the value returned by
+ the rPDULoadBankConfigLowLoadThreshold OID.
+
+ Maximum value must be less than or equal to the value
+ returned by the rPDULoadBankConfigOverloadThreshold OID.
+
+ -1 will be returned if the device has no banks."
+
+ ::= { rPDULoadBankConfigEntry 3 }
+
+rPDULoadBankConfigOverloadThreshold OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "A threshold that indicates the power consumption of
+ the load has entered an overload condition. It is
+ represented in amps. A warning will be issued when the
+ load is greater than or equal to the threshold value.
+
+ Minimum value must be greater than or equal to the value
+ returned by the rPDULoadBankConfigNearOverloadThreshold OID.
+
+ Maximum value must be less than or equal to the value
+ returned by the rPDULoadDevMaxBankLoad OID.
+
+ -1 will be returned if the device has no banks."
+
+ ::= { rPDULoadBankConfigEntry 4 }
+
+
+-- the rPDUOutletDevice group
+
+rPDUOutletDevCommand OBJECT-TYPE
+ SYNTAX INTEGER {
+ noCommandAll (1),
+ immediateAllOn (2),
+ immediateAllOff (3),
+ immediateAllReboot (4),
+ delayedAllOn (5),
+ delayedAllOff (6),
+ delayedAllReboot (7),
+ cancelAllPendingCommands (8),
+ gracefulAllOff (9),
+ gracefulAllReboot (10)
+ }
+
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Setting this OID to immediateAllOn (2) will turn all outlets
+ on immediately.
+
+ Setting this OID to immediateAllOff (3) will turn all outlets
+ off immediately.
+
+ Setting this OID to immediateAllReboot (4) will reboot all outlets
+ immediately.
+
+ Setting this OID to delayedAllOn (5) will turn all outlets on as
+ defined by each outlet's rPDUOutletConfigPowerOnTime OID value.
+
+ Setting this OID to delayedAllOff (6) will turn all outlets
+ off as defined by each outlet's rPDUOutletConfigPowerOffTime OID value.
+
+ Setting this OID to delayedAllReboot (7) will cause a
+ delayedAllOff command to be performed. Once all outlets are off,
+ the Switched Rack PDU will then delay the largest
+ rPDUOutletConfigRebootDuration OID time, and then perform a
+ delayedAllOn command.
+
+ Setting this OID to cancelAllPendingCommands (8) will cause all pending
+ commands on the Switched Rack PDU to be canceled.
+
+ Setting this variable to gracefulAllOff (9) will cause the
+ Switched Rack PDU to shut all outlets off after it waits the
+ servers graceful shutdown time and each outlet's shutdown delay.
+
+ Setting this variable to gracefulAllReboot (10) will cause the
+ Switched Rack PDU to shut all outlets off after it waits the
+ servers graceful shutdown time and each outlet's shutdown delay.
+ Once all outlet are off, it will wait until the UPS reaches the
+ configured minimum return battery capacity, then each outlet's
+ return delay before it turns the outlet back on.
+
+ Getting this OID will return the noCommandAll (1) value."
+ ::= { rPDUOutletDevice 1 }
+
+rPDUOutletDevColdstartDelay OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The amount of delay, in seconds, between when
+ power is provided to the Switched Rack PDU and
+ when the Switched Rack PDU provides basic master
+ power to the outlets.
+
+ Allowed values are:
+
+ -1 - never apply power automatically.
+ 0 - apply power immediately.
+ 1 to 300 - delay up to 300 seconds (5 minutes)."
+ ::= { rPDUOutletDevice 2 }
+
+rPDUOutletDevNumCntrlOutlets OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of controlled outlets on this Switched Rack PDU."
+ ::= { rPDUOutletDevice 3 }
+
+rPDUOutletDevNumTotalOutlets OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The total number of outlets on this Rack PDU."
+ ::= { rPDUOutletDevice 4 }
+
+
+-- the rPDUOutletPhase group
+
+rPDUOutletPhaseTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF OutletPhaseEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for management of outlets on a per phase basis."
+ ::= { rPDUOutletPhase 1 }
+
+rPDUOutletPhaseEntry OBJECT-TYPE
+ SYNTAX OutletPhaseEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The phase to manage."
+ INDEX { rPDUOutletPhaseIndex}
+ ::= { rPDUOutletPhaseTable 1 }
+
+OutletPhaseEntry ::=
+ SEQUENCE {
+ rPDUOutletPhaseIndex INTEGER,
+ rPDUOutletPhaseOverloadRestriction INTEGER
+ }
+
+rPDUOutletPhaseIndex OBJECT-TYPE
+ SYNTAX INTEGER {
+ phase1 (1),
+ phase2 (2),
+ phase3 (3)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the Switched Rack PDU phase entry."
+ ::= { rPDUOutletPhaseEntry 1 }
+
+rPDUOutletPhaseOverloadRestriction OBJECT-TYPE
+ SYNTAX INTEGER {
+ alwaysAllowTurnON (1),
+ restrictOnNearOverload (2),
+ restrictOnOverload (3)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "This OID controls the behavior of a Switched Rack PDU
+ phase when an overload condition is possible and
+ additional outlets are requested to be turned on.
+
+ Setting this OID to alwaysAllowTurnON (1) will always allow
+ the outlets on the corresponding phase to turn on.
+
+ Setting this OID to restrictOnNearOverload (2) will not allow
+ outlets on the corresponding phase to turn on if the
+ rPDULoadConfigNearOverloadThreshold OID is exceeded.
+
+ Setting this OID to restrictOnOverload (3) will not allow
+ outlets on the corresponding phase to turn on if the
+ rPDULoadConfigOverloadThreshold OID is exceeded."
+ ::= { rPDUOutletPhaseEntry 2 }
+
+
+-- the rPDUOutletControl group
+
+rPDUOutletControlTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF RPDUOutletControlEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for control of the individual outlets.
+ The number of entries is contained in the
+ rPDUOutletDevNumCntrlOutlets OID."
+ ::= { rPDUOutletControl 1 }
+
+rPDUOutletControlEntry OBJECT-TYPE
+ SYNTAX RPDUOutletControlEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The outlet to control."
+ INDEX { rPDUOutletControlIndex}
+ ::= { rPDUOutletControlTable 1 }
+
+RPDUOutletControlEntry ::=
+ SEQUENCE {
+ rPDUOutletControlIndex INTEGER,
+ rPDUOutletControlOutletName DisplayString,
+ rPDUOutletControlOutletPhase INTEGER,
+ rPDUOutletControlOutletCommand INTEGER,
+ rPDUOutletControlOutletBank INTEGER
+ }
+
+rPDUOutletControlIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the outlet entry."
+ ::= { rPDUOutletControlEntry 1 }
+
+rPDUOutletControlOutletName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The name of the outlet. Maximum size is dependent on device.
+ An error will be returned if the set request exceeds the max size.
+ This OID is provided for informational purposes only."
+ ::= { rPDUOutletControlEntry 2 }
+
+rPDUOutletControlOutletPhase OBJECT-TYPE
+ SYNTAX INTEGER {
+ phase1 (1),
+ phase2 (2),
+ phase3 (3),
+ phase1-2 (4),
+ phase2-3 (5),
+ phase3-1 (6)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The phase/s associated with this outlet.
+
+ For single phase devices, this object will always
+ return phase1(1).
+
+ For 3-phase devices, this object will return phase1 (1),
+ phase2 (2), or phase3 (3) for outlets tied to a single
+ phase. For outlets tied to two phases, this object will
+ return phase1-2 (4) for phases 1 and 2, phase2-3 (5) for
+ phases 2 and 3, and phase3-1 (6) for phases 3 and 1."
+ ::= { rPDUOutletControlEntry 3 }
+
+rPDUOutletControlOutletCommand OBJECT-TYPE
+ SYNTAX INTEGER {
+ immediateOn (1),
+ immediateOff (2),
+ immediateReboot (3),
+ delayedOn (4),
+ delayedOff (5),
+ delayedReboot (6),
+ cancelPendingCommand (7),
+ gracefulOff (8),
+ gracefulReboot (9)
+
+ }
+
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this variable will return the outlet state. If
+ the outlet is on, the immediateOn (1) value will be returned.
+ If the outlet is off, the immediateOff (2) value will be
+ returned.
+
+
+ Setting this variable to immediateOn (1) will immediately turn
+ the outlet on.
+
+ Setting this variable to immediateOff (2) will immediately turn
+ the outlet off.
+
+ Setting this variable to immediateReboot (3) will immediately
+ reboot the outlet.
+
+ Setting this variable to delayedOn (4) will turn the outlet on
+ after the rPDUOutletConfigPowerOnTime OID time has elapsed.
+
+ Setting this variable to delayedOff (5) will turn the outlet off
+ after the rPDUOutletConfigPowerOffTime OID time has elapsed.
+
+ Setting this variable to delayedReboot (6) will cause the
+ Switched Rack PDU to perform a delayedOff command, wait the
+ rPDUOutletConfigRebootDuration OID time, and then perform a
+ delayedOn command.
+
+ Setting this variable to cancelPendingCommand (7) will cause any
+ pending command to this outlet to be canceled.
+
+ Setting this variable to gracefulOff (8) will cause the
+ Switched Rack PDU to shut the outlet off after it waits the
+ servers graceful shutdown time and the outlets shutdown delay.
+
+ Setting this variable to gracefulReboot (9) will cause the
+ Switched Rack PDU to shut the outlet off after it waits the
+ servers graceful shutdown time and the outlets shutdown delay.
+ Once the outlet is off, it will wait until the UPS reaches the
+ configured minimum return battery capacity, then the outlets
+ return delay before it turns the outlet back on."
+
+ ::= { rPDUOutletControlEntry 4 }
+
+rPDUOutletControlOutletBank OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The bank associated with this outlet."
+ ::= { rPDUOutletControlEntry 5 }
+
+
+-- the rPDUOutletConfig group
+
+rPDUOutletConfigTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF RPDUOutletConfigEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for configuration of individual outlets. The number of
+ entries is contained in the rPDUOutletDevNumCntrlOutlets OID."
+ ::= { rPDUOutletConfig 1 }
+
+rPDUOutletConfigEntry OBJECT-TYPE
+ SYNTAX RPDUOutletConfigEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The outlet to configure."
+ INDEX { rPDUOutletConfigIndex}
+ ::= { rPDUOutletConfigTable 1 }
+
+RPDUOutletConfigEntry ::=
+ SEQUENCE {
+ rPDUOutletConfigIndex INTEGER,
+ rPDUOutletConfigOutletName DisplayString,
+ rPDUOutletConfigOutletPhase INTEGER,
+ rPDUOutletConfigPowerOnTime INTEGER,
+ rPDUOutletConfigPowerOffTime INTEGER,
+ rPDUOutletConfigRebootDuration INTEGER,
+ rPDUOutletConfigOutletBank INTEGER
+ }
+
+rPDUOutletConfigIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the outlet entry."
+ ::= { rPDUOutletConfigEntry 1 }
+
+rPDUOutletConfigOutletName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The name of the outlet. Maximum size is dependent on device.
+ An error will be returned if the set request exceeds the max size."
+ ::= { rPDUOutletConfigEntry 2 }
+
+rPDUOutletConfigOutletPhase OBJECT-TYPE
+ SYNTAX INTEGER {
+ phase1 (1),
+ phase2 (2),
+ phase3 (3),
+ phase1-2 (4),
+ phase2-3 (5),
+ phase3-1 (6)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The phase/s associated with this outlet.
+
+ For single phase devices, this object will always
+ return phase1(1).
+
+ For 3-phase devices, this object will return phase1 (1),
+ phase2 (2), or phase3 (3) for outlets tied to a single
+ phase. For outlets tied to two phases, this object will
+ return phase1-2 (4) for phases 1 and 2, phase2-3 (5) for
+ phases 2 and 3, and phase3-1 (6) for phases 3 and 1."
+ ::= { rPDUOutletConfigEntry 3 }
+
+rPDUOutletConfigPowerOnTime OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The amount of time (in seconds) the outlet will delay
+ powering on at coldstart or when a command that requires
+ a turn-on delay is issued.
+
+ Allowed values are:
+
+ -1 - never power on.
+ 0 - power on immediately.
+ 1 to 300 - power on up to 300 seconds (5 minutes) after being
+ commanded."
+ ::= { rPDUOutletConfigEntry 4 }
+
+rPDUOutletConfigPowerOffTime OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The amount of time (in seconds) the outlet will delay
+ powering off when a command that requires
+ a turn-off delay is issued.
+
+ Allowed values are:
+
+ -1 - never power off.
+ 0 - power off immediately.
+ 1 to 300 - power off up to 300 seconds (5 minutes) after being
+ commanded."
+ ::= { rPDUOutletConfigEntry 5 }
+
+rPDUOutletConfigRebootDuration OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "During a reboot sequence, power is turned off and then
+ back on. This OID defines the amount of time to wait,
+ in seconds, after turning the power off, at the start
+ of the sequence, before turning power back on, at the
+ end of the reboot sequence.
+
+ Allowed range is any value between 5 and 60 seconds (1 minute)."
+ ::= { rPDUOutletConfigEntry 6 }
+
+rPDUOutletConfigOutletBank OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The bank associated with this outlet."
+ ::= { rPDUOutletConfigEntry 7 }
+
+
+-- the rPDUOutletStatus group
+
+rPDUOutletStatusTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF RPDUOutletStatusEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for getting of status of individual outlets. The number of
+ entries is contained in the rPDUOutletDevNumCntrlOutlets OID."
+ ::= { rPDUOutletStatus 1 }
+
+rPDUOutletStatusEntry OBJECT-TYPE
+ SYNTAX RPDUOutletStatusEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The outlet to gather status from."
+ INDEX { rPDUOutletStatusIndex}
+ ::= { rPDUOutletStatusTable 1 }
+
+RPDUOutletStatusEntry ::=
+ SEQUENCE {
+ rPDUOutletStatusIndex INTEGER,
+ rPDUOutletStatusOutletName DisplayString,
+ rPDUOutletStatusOutletPhase INTEGER,
+ rPDUOutletStatusOutletState INTEGER,
+ rPDUOutletStatusCommandPending INTEGER,
+ rPDUOutletStatusOutletBank INTEGER
+ }
+
+rPDUOutletStatusIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the outlet entry."
+ ::= { rPDUOutletStatusEntry 1 }
+
+rPDUOutletStatusOutletName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The name of the outlet. Maximum size is dependent on device.
+ An error will be returned if the set request exceeds the max size.
+ This OID is provided for informational purposes only."
+ ::= { rPDUOutletStatusEntry 2 }
+
+rPDUOutletStatusOutletPhase OBJECT-TYPE
+ SYNTAX INTEGER {
+ phase1 (1),
+ phase2 (2),
+ phase3 (3),
+ phase1-2 (4),
+ phase2-3 (5),
+ phase3-1 (6)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The phase/s associated with this outlet.
+
+ For single phase devices, this object will always
+ return phase1(1).
+
+ For 3-phase devices, this object will return phase1 (1),
+ phase2 (2), or phase3 (3) for outlets tied to a single
+ phase. For outlets tied to two phases, this object will
+ return phase1-2 (4) for phases 1 and 2, phase2-3 (5) for
+ phases 2 and 3, and phase3-1 (6) for phases 3 and 1."
+ ::= { rPDUOutletStatusEntry 3 }
+
+rPDUOutletStatusOutletState OBJECT-TYPE
+ SYNTAX INTEGER {
+ outletStatusOn (1),
+ outletStatusOff (2)
+ }
+
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this variable will return the outlet state. If
+ the outlet is on, the outletStatusOn (1) value will be returned.
+ If the outlet is off, the outletStatusOff (2) value will be
+ returned. "
+ ::= { rPDUOutletStatusEntry 4 }
+
+rPDUOutletStatusCommandPending OBJECT-TYPE
+ SYNTAX INTEGER {
+ outletStatusCommandPending (1),
+ outletStatusNoCommandPending (2)
+ }
+
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this variable will return the command pending
+ state of the outlet. If a command is pending on the
+ outlet, the outletStatusCommandPending (1) value
+ will be returned. If there is not a command pending
+ on the outlet, the outletStatusNoCommandPending (2)
+ will be returned."
+ ::= { rPDUOutletStatusEntry 5 }
+
+rPDUOutletStatusOutletBank OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The bank associated with this outlet."
+ ::= { rPDUOutletStatusEntry 6 }
+
+
+-- the rPDUOutletBank group
+
+rPDUOutletBankTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF OutletBankEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for management of outlets on a per bank basis."
+ ::= { rPDUOutletBank 1 }
+
+rPDUOutletBankEntry OBJECT-TYPE
+ SYNTAX OutletBankEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The bank to manage."
+ INDEX { rPDUOutletBankIndex}
+ ::= { rPDUOutletBankTable 1 }
+
+OutletBankEntry ::=
+ SEQUENCE {
+ rPDUOutletBankIndex INTEGER,
+ rPDUOutletBankOverloadRestriction INTEGER
+ }
+
+rPDUOutletBankIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the Switched Rack PDU bank entry."
+ ::= { rPDUOutletBankEntry 1 }
+
+rPDUOutletBankOverloadRestriction OBJECT-TYPE
+ SYNTAX INTEGER {
+ alwaysAllowTurnON (1),
+ restrictOnNearOverload (2),
+ restrictOnOverload (3)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "This OID controls the behavior of a Switched Rack PDU
+ bank when an overload condition is possible and
+ additional outlets are requested to be turned on.
+
+ Setting this OID to alwaysAllowTurnON (1) will always allow
+ the outlets on the corresponding bank to turn on.
+
+ Setting this OID to restrictOnNearOverload (2) will not allow
+ outlets on the corresponding bank to turn on if the
+ rPDULoadConfigNearOverloadThreshold OID is exceeded.
+
+ Setting this OID to restrictOnOverload (3) will not allow
+ outlets on the corresponding bank to turn on if the
+ rPDULoadConfigOverloadThreshold OID is exceeded."
+ ::= { rPDUOutletBankEntry 2 }
+
+-- the rPDUPowerSupplyDevice group
+
+rPDUPowerSupply1Status OBJECT-TYPE
+ SYNTAX INTEGER {
+ powerSupply1Ok (1),
+ powerSupply1Failed (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this OID will return powerSupply1Ok(1) if power
+ supply 1 is functioning normally. If not functioning normally,
+ this OID will return powerSupply1Failed(2)."
+ ::= { rPDUPowerSupplyDevice 1 }
+
+rPDUPowerSupply2Status OBJECT-TYPE
+ SYNTAX INTEGER {
+ powerSupply2Ok (1),
+ powerSupply2Failed (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this OID will return powerSupply2Ok(1) if power
+ supply 2 is functioning normally. If not functioning normally,
+ this OID will return powerSupply2Failed(2)."
+ ::= { rPDUPowerSupplyDevice 2 }
+
+
+
+-- the dm3IdentSystem group
+
+dm3IdentSysDescriptionTableSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of DC description records."
+ ::= { dm3IdentSystem 1 }
+
+dm3IdentSysDescriptionTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF IdentSysDescriptionEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for accessing description records of the powerplant. The number of
+ entries is contained in the dm3IdentSysDescriptionTableSize OID."
+ ::= { dm3IdentSystem 2 }
+
+dm3IdentSysDescriptionEntry OBJECT-TYPE
+ SYNTAX IdentSysDescriptionEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The powerplant description record to reference."
+ INDEX { dm3IdentSysDescriptionIndex }
+ ::= { dm3IdentSysDescriptionTable 1 }
+
+IdentSysDescriptionEntry ::=
+ SEQUENCE {
+ dm3IdentSysDescriptionIndex INTEGER,
+ dm3IdentSysDescriptionText DisplayString
+ }
+
+dm3IdentSysDescriptionIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the DC powerplant description record."
+ ::= { dm3IdentSysDescriptionEntry 1 }
+
+dm3IdentSysDescriptionText OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A 16 character text field describing the DC power plant device.
+ This field can be configured from the dm3ConfigSysDescriptionText OID."
+ ::= { dm3IdentSysDescriptionEntry 2 }
+
+dm3IdentSysModel OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Model type of the DC power plant."
+ ::= { dm3IdentSystem 3 }
+
+dm3IdentSysCntrlRev OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Integer representation of the hardware revision of the Master Controller board."
+ ::= { dm3IdentSystem 4 }
+
+dm3IdentSysFWVersion OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Integer representation of the power plant Master Controller firmware revision."
+ ::= { dm3IdentSystem 5 }
+
+-- the dm3ConfigSystem group
+
+dm3ConfigSysDescriptionTableSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of DC description records."
+ ::= { dm3ConfigSystem 1 }
+
+dm3ConfigSysDescriptionTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ConfigSysDescriptionEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for accessing description records of the powerplant. The number of
+ entries is contained in the dm3ConfigSysDescriptionTableSize OID."
+ ::= { dm3ConfigSystem 2 }
+
+dm3ConfigSysDescriptionEntry OBJECT-TYPE
+ SYNTAX ConfigSysDescriptionEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The powerplant description record to reference."
+ INDEX { dm3ConfigSysDescriptionIndex }
+ ::= { dm3ConfigSysDescriptionTable 1 }
+
+ConfigSysDescriptionEntry ::=
+ SEQUENCE {
+ dm3ConfigSysDescriptionIndex INTEGER,
+ dm3ConfigSysDescriptionText DisplayString
+ }
+
+dm3ConfigSysDescriptionIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the DC powerplant description record."
+
+ ::= { dm3ConfigSysDescriptionEntry 1 }
+
+dm3ConfigSysDescriptionText OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "16 character text field describing the DC power plant device."
+
+ ::= { dm3ConfigSysDescriptionEntry 2 }
+
+dm3ConfigSysHighTempThresh OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Ambient high temperature threshold. Temperature sensor located on Master
+ Controller board.
+
+ Values are represented in thousandths of a degree.
+ Units are displayed in the scale shown in
+ the 'dm3StatusSysTempUnits' OID (Celsius or Fahrenheit).
+
+ Attempts to set the value above or below the acceptable range of the powerplant
+ will cause the value to be set at the high or low point of the range respectively."
+ ::= { dm3ConfigSystem 3 }
+
+dm3ConfigSysHighTempAlarm OBJECT-TYPE
+ SYNTAX INTEGER {
+ alarmIgnore (1),
+ alarmRelay1 (2),
+ alarmRelay2 (3),
+ alarmRelay3 (4),
+ alarmRelay4 (5),
+ alarmRelay5 (6),
+ alarmRelay6 (7),
+ alarmMinor (8),
+ alarmMajor (9)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "For the System High Temperature Alarm;
+ Setting this OID to alarmIgnore (1) results in the alarm condition being ignored.
+ Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an
+ alarm condition.
+ Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an
+ alarm condition.
+ Setting this OID to alarmMajor (9) causes the Major relay to be activated for an
+ alarm condition."
+ ::= { dm3ConfigSystem 4 }
+
+dm3ConfigSysLowTempThresh OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Ambient low temperature threshold. Temperature sensor located on Master
+ Controller board.
+
+ Values are represented in thousandths of a degree.
+ Units are displayed in the scale shown in
+ the 'dm3StatusSysTempUnits' OID (Celsius or Fahrenheit).
+
+ Attempts to set the value above or below the acceptable range of the powerplant
+ will cause the value to be set at the high or low point of the range respectively."
+ ::= { dm3ConfigSystem 5 }
+
+dm3ConfigSysLowTempAlarm OBJECT-TYPE
+ SYNTAX INTEGER {
+ alarmIgnore (1),
+ alarmRelay1 (2),
+ alarmRelay2 (3),
+ alarmRelay3 (4),
+ alarmRelay4 (5),
+ alarmRelay5 (6),
+ alarmRelay6 (7),
+ alarmMinor (8),
+ alarmMajor (9)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "For the System Low Temperature Alarm;
+ Setting this OID to alarmIgnore (1) results in the alarm condition being ignored.
+ Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an
+ alarm condition.
+ Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an
+ alarm condition.
+ Setting this OID to alarmMajor (9) causes the Major relay to be activated for an
+ alarm condition."
+ ::= { dm3ConfigSystem 6 }
+
+dm3ConfigSysHardwareTempAlarm OBJECT-TYPE
+ SYNTAX INTEGER {
+ alarmIgnore (1),
+ alarmRelay1 (2),
+ alarmRelay2 (3),
+ alarmRelay3 (4),
+ alarmRelay4 (5),
+ alarmRelay5 (6),
+ alarmRelay6 (7),
+ alarmMinor (8),
+ alarmMajor (9)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "For the System Hardware Temperature Alarm;
+ Setting this OID to alarmIgnore (1) results in the alarm condition being ignored.
+ Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an
+ alarm condition.
+ Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an
+ alarm condition.
+ Setting this OID to alarmMajor (9) causes the Major relay to be activated for an
+ alarm condition."
+ ::= { dm3ConfigSystem 7 }
+
+dm3ConfigSysRemoteAccess OBJECT-TYPE
+ SYNTAX INTEGER {
+ accessEnabled (1),
+ accessDisabled (2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "
+ This OID is used to disable remote write access to the power plant.
+ Setting this OID to accessEnabled (1) will have no affect.
+ Setting this OID to accessDisabled (2) will disable the ability to
+ remotely configure the DC powerplant.
+
+ Once remote access is disabled, it can only be restored from the front
+ panel of the DC power plant."
+ ::= { dm3ConfigSystem 8 }
+
+
+-- the dm3ConfigLVD group
+
+dm3ConfigLVDTableSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of DC powerplant LVDs controllable
+ by this IP address."
+ ::= { dm3ConfigLVD 1 }
+
+dm3ConfigLVDTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ConfigLVDEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for accessing settings of the LVDs. The number of
+ entries is contained in the dm3ConfigLVDTableSize OID."
+ ::= { dm3ConfigLVD 2 }
+
+dm3ConfigLVDEntry OBJECT-TYPE
+ SYNTAX ConfigLVDEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The LVD to configure."
+ INDEX { dm3ConfigLVDIndex }
+ ::= { dm3ConfigLVDTable 1 }
+
+ConfigLVDEntry ::=
+ SEQUENCE {
+ dm3ConfigLVDIndex INTEGER,
+ dm3ConfigLVDName DisplayString,
+ dm3ConfigLVDEnable INTEGER,
+ dm3ConfigLVDTripThresh INTEGER,
+ dm3ConfigLVDResetThresh INTEGER,
+ dm3ConfigLVDOpenAlarm INTEGER,
+ dm3ConfigLVDHWAlarm INTEGER
+ }
+
+dm3ConfigLVDIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the DC powerplant LVD."
+ ::= { dm3ConfigLVDEntry 1 }
+
+dm3ConfigLVDName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The name of the LVD. The maximum value is 16 characters."
+ ::= { dm3ConfigLVDEntry 2 }
+
+dm3ConfigLVDEnable OBJECT-TYPE
+ SYNTAX INTEGER {
+ enabledYes (1),
+ enabledNo (2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "This OID is used to control and indicate if the LVD is on or off.
+ Setting this OID to enabledYes (1) will enable (turn on) the LVD.
+ Setting this OID to enabledNo (2) will disable (turn off) the LVD."
+ ::= { dm3ConfigLVDEntry 3 }
+
+dm3ConfigLVDTripThresh OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "LVD Trip threshold. If voltage exceeds threshold, the LVD will trip.
+
+ Values are represented in thousandths of Volts (mV).
+ Attempts to set the value above or below the acceptable range of the powerplant
+ will cause the value to be set at the high or low point of the range respectively."
+ ::= { dm3ConfigLVDEntry 4 }
+
+dm3ConfigLVDResetThresh OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "LVD Reset threshold. If voltage exceeds threshold, the LVD will reset.
+
+ Values are represented in thousandths of Volts (mV).
+ Attempts to set the value above or below the acceptable range of the powerplant
+ will cause the value to be set at the high or low point of the range respectively."
+ ::= { dm3ConfigLVDEntry 5 }
+
+dm3ConfigLVDOpenAlarm OBJECT-TYPE
+ SYNTAX INTEGER {
+ alarmIgnore (1),
+ alarmRelay1 (2),
+ alarmRelay2 (3),
+ alarmRelay3 (4),
+ alarmRelay4 (5),
+ alarmRelay5 (6),
+ alarmRelay6 (7),
+ alarmMinor (8),
+ alarmMajor (9)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "For the LVD Open Alarm;
+ Setting this OID to alarmIgnore (1) results in the alarm condition being ignored.
+ Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an
+ alarm condition.
+ Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an
+ alarm condition.
+ Setting this OID to alarmMajor (9) causes the Major relay to be activated for an
+ alarm condition."
+ ::= { dm3ConfigLVDEntry 6 }
+
+dm3ConfigLVDHWAlarm OBJECT-TYPE
+SYNTAX INTEGER {
+ alarmIgnore (1),
+ alarmRelay1 (2),
+ alarmRelay2 (3),
+ alarmRelay3 (4),
+ alarmRelay4 (5),
+ alarmRelay5 (6),
+ alarmRelay6 (7),
+ alarmMinor (8),
+ alarmMajor (9)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "For the LVD Hardware Alarm;
+ Setting this OID to alarmIgnore (1) results in the alarm condition being ignored.
+ Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an
+ alarm condition.
+ Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an
+ alarm condition.
+ Setting this OID to alarmMajor (9) causes the Major relay to be activated for an
+ alarm condition."
+ ::= { dm3ConfigLVDEntry 7 }
+
+
+-- the dm3ConfigBattery group
+
+dm3ConfigBattFloatVolt OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Battery Float Voltage. This setting controls the power plant voltage.
+
+ Values are represented in thousandths of Volts (mV).
+ Attempts to set the value above or below the acceptable range of the powerplant
+ will cause the value to be set at the high or low point of the range respectively."
+ ::= { dm3ConfigBattery 1 }
+
+dm3ConfigBattMaxRecharge OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Battery Maximum Recharge Rate. This setting controls the battery max
+ recharge rate. The value is based on C/20 for 240 AHr battery string.
+
+ Values are represented in thousandths of Amps (mA).
+ Attempts to set the value above or below the acceptable range of the powerplant
+ will cause the value to be set at the high or low point of the range respectively."
+ ::= { dm3ConfigBattery 2 }
+
+dm3ConfigBattDischargeThresh OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Battery discharge threshold. If battery output current exceeds threshold
+ a battery discharge alarm will occur.
+
+ Values are represented in thousandths of Amps (mA).
+ Attempts to set the value above or below the acceptable range of the powerplant
+ will cause the value to be set at the high or low point of the range respectively."
+ ::= { dm3ConfigBattery 3 }
+
+dm3ConfigBattDischargeAlarm OBJECT-TYPE
+ SYNTAX INTEGER {
+ alarmIgnore (1),
+ alarmRelay1 (2),
+ alarmRelay2 (3),
+ alarmRelay3 (4),
+ alarmRelay4 (5),
+ alarmRelay5 (6),
+ alarmRelay6 (7),
+ alarmMinor (8),
+ alarmMajor (9)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "For the Battery Discharge Alarm;
+ Setting this OID to alarmIgnore (1) results in the alarm condition being ignored.
+ Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an
+ alarm condition.
+ Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an
+ alarm condition.
+ Setting this OID to alarmMajor (9) causes the Major relay to be activated for an
+ alarm condition."
+
+ ::= { dm3ConfigBattery 4 }
+
+dm3ConfigBattHighVoltThresh OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Battery high voltage threshold. If system battery voltage exceeds threshold
+ a battery high voltage alarm will occur.
+
+ Values are represented in thousandths of Volts (mV).
+ Attempts to set the value above or below the acceptable range of the powerplant
+ will cause the value to be set at the high or low point of the range respectively."
+ ::= { dm3ConfigBattery 5 }
+
+dm3ConfigBattHighVoltAlarm OBJECT-TYPE
+ SYNTAX INTEGER {
+ alarmIgnore (1),
+ alarmRelay1 (2),
+ alarmRelay2 (3),
+ alarmRelay3 (4),
+ alarmRelay4 (5),
+ alarmRelay5 (6),
+ alarmRelay6 (7),
+ alarmMinor (8),
+ alarmMajor (9)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "For the Battery High Voltage Alarm;
+ Setting this OID to alarmIgnore (1) results in the alarm condition being ignored.
+ Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an
+ alarm condition.
+ Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an
+ alarm condition.
+ Setting this OID to alarmMajor (9) causes the Major relay to be activated for an
+ alarm condition."
+
+ ::= { dm3ConfigBattery 6 }
+
+dm3ConfigBattLowVoltThresh OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Battery low voltage threshold. If system battery voltage is under threshold
+ a battery low voltage alarm will occur.
+
+ Values are represented in thousandths of Volts (mV).
+ Attempts to set the value above or below the acceptable range of the powerplant
+ will cause the value to be set at the high or low point of the range respectively."
+ ::= { dm3ConfigBattery 7 }
+
+dm3ConfigBattLowVoltAlarm OBJECT-TYPE
+ SYNTAX INTEGER {
+ alarmIgnore (1),
+ alarmRelay1 (2),
+ alarmRelay2 (3),
+ alarmRelay3 (4),
+ alarmRelay4 (5),
+ alarmRelay5 (6),
+ alarmRelay6 (7),
+ alarmMinor (8),
+ alarmMajor (9)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "For the Battery Low Voltage Alarm;
+ Setting this OID to alarmIgnore (1) results in the alarm condition being ignored.
+ Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an
+ alarm condition.
+ Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an
+ alarm condition.
+ Setting this OID to alarmMajor (9) causes the Major relay to be activated for an
+ alarm condition."
+
+ ::= { dm3ConfigBattery 8 }
+
+dm3ConfigBattHighTempThresh OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Battery high temperature threshold. If system battery temperature exceeds threshold
+ a battery high temperature alarm will occur.
+
+ Values are represented in thousandths of a degree.
+ Units are displayed in the scale shown in
+ the 'dm3StatusSysTempUnits' OID (Celsius or Fahrenheit).
+
+ Attempts to set the value above or below the acceptable range of the powerplant
+ will cause the value to be set at the high or low point of the range respectively."
+
+ ::= { dm3ConfigBattery 9 }
+
+dm3ConfigBattHighTempAlarm OBJECT-TYPE
+ SYNTAX INTEGER {
+ alarmIgnore (1),
+ alarmRelay1 (2),
+ alarmRelay2 (3),
+ alarmRelay3 (4),
+ alarmRelay4 (5),
+ alarmRelay5 (6),
+ alarmRelay6 (7),
+ alarmMinor (8),
+ alarmMajor (9)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "For the Battery High Temperature Alarm;
+ Setting this OID to alarmIgnore (1) results in the alarm condition being ignored.
+ Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an
+ alarm condition.
+ Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an
+ alarm condition.
+ Setting this OID to alarmMajor (9) causes the Major relay to be activated for an
+ alarm condition."
+
+ ::= { dm3ConfigBattery 10 }
+
+dm3ConfigBattLowTempThresh OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Battery low temperature threshold. If system battery temperature is under threshold
+ a battery low temperature alarm will occur.
+
+ Values are represented in thousandths of a degree.
+ Units are displayed in the scale shown in
+ the 'dm3StatusSysTempUnits' OID (Celsius or Fahrenheit).
+
+ Attempts to set the value above or below the acceptable range of the powerplant
+ will cause the value to be set at the high or low point of the range respectively."
+
+ ::= { dm3ConfigBattery 11 }
+
+dm3ConfigBattLowTempAlarm OBJECT-TYPE
+ SYNTAX INTEGER {
+ alarmIgnore (1),
+ alarmRelay1 (2),
+ alarmRelay2 (3),
+ alarmRelay3 (4),
+ alarmRelay4 (5),
+ alarmRelay5 (6),
+ alarmRelay6 (7),
+ alarmMinor (8),
+ alarmMajor (9)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "For the Battery Low Temperature Alarm;
+ Setting this OID to alarmIgnore (1) results in the alarm condition being ignored.
+ Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an
+ alarm condition.
+ Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an
+ alarm condition.
+ Setting this OID to alarmMajor (9) causes the Major relay to be activated for an
+ alarm condition."
+
+ ::= { dm3ConfigBattery 12 }
+
+dm3ConfigBattAmpHour OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Battery Amp-Hour Size. Units are thousandths of Amp hours (mAHr).
+
+ Attempts to set the value above or below the acceptable range of the powerplant
+ will cause the value to be set at the high or low point of the range respectively."
+ ::= { dm3ConfigBattery 13 }
+
+dm3ConfigCompMethod OBJECT-TYPE
+ SYNTAX INTEGER {
+ tempcompOn (1),
+ tempcompOff (2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "This OID is used to configure and get the state of the battery
+ temperature compensation.
+
+ Setting this OID to tempcompOn (1) will enable/turn on the battery temperature compensation.
+ Setting this OID to tempcompOff (2) will disable/turn off the battery temperature compensation."
+ ::= { dm3ConfigBattery 14 }
+
+dm3ConfigCompTempCoeff OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Compensation Temperature Coefficient. (uV/degC/cell).
+
+ Units are presented in microvolts.
+ Attempts to set the value above or below the acceptable range of the powerplant
+ will cause the value to be set at the high or low point of the range respectively."
+ ::= { dm3ConfigBattery 15 }
+
+dm3ConfigHighKneeTemp OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "High Knee for temperature compensation: Compensation temperature coefficient
+ becomes 0mV/degC/cell.
+
+ Values are represented in thousandths of degrees Celcius.
+ Attempts to set the value above or below the acceptable range of the powerplant
+ will cause the value to be set at the high or low point of the range respectively."
+ ::= { dm3ConfigBattery 16 }
+
+dm3ConfigLowKneeTemp OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Low Knee for temperature compensation: Compensation temperature coefficient
+ becomes 0mV/degC/cell.
+
+ Values are represented in thousandths of degrees Celcius.
+ Attempts to set the value above or below the acceptable range of the powerplant
+ will cause the value to be set at the high or low point of the range respectively."
+ ::= { dm3ConfigBattery 17 }
+
+dm3ConfigBattHwCurrentAlarm OBJECT-TYPE
+ SYNTAX INTEGER {
+ alarmIgnore (1),
+ alarmRelay1 (2),
+ alarmRelay2 (3),
+ alarmRelay3 (4),
+ alarmRelay4 (5),
+ alarmRelay5 (6),
+ alarmRelay6 (7),
+ alarmMinor (8),
+ alarmMajor (9)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "For the Battery Current Hardware Alarm (indicating current is outside realistic
+ limits, or a possible measurement fault;
+ Setting this OID to alarmIgnore (1) results in the alarm condition being ignored.
+ Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an
+ alarm condition.
+ Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an
+ alarm condition.
+ Setting this OID to alarmMajor (9) causes the Major relay to be activated for an
+ alarm condition."
+
+ ::= { dm3ConfigBattery 18 }
+
+dm3ConfigBattHwTempAlarm OBJECT-TYPE
+ SYNTAX INTEGER {
+ alarmIgnore (1),
+ alarmRelay1 (2),
+ alarmRelay2 (3),
+ alarmRelay3 (4),
+ alarmRelay4 (5),
+ alarmRelay5 (6),
+ alarmRelay6 (7),
+ alarmMinor (8),
+ alarmMajor (9)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "For the Battery Temperature Hardware Alarm (indicating temperature is outside realistic
+ limits, or a possible measurement fault;
+ Setting this OID to alarmIgnore (1) results in the alarm condition being ignored.
+ Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an
+ alarm condition.
+ Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an
+ alarm condition.
+ Setting this OID to alarmMajor (9) causes the Major relay to be activated for an
+ alarm condition."
+
+ ::= { dm3ConfigBattery 19 }
+
+
+-- the dm3ConfigRectThresh group
+dm3ConfigRectHighVoltThresh OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Rectifier high voltage threshold. If rectifier voltage exceeds threshold
+ a rectifier high voltage alarm will occur.
+
+ Values are represented in thousandths of Volts (mV).
+ Attempts to set the value above or below the acceptable range of the powerplant
+ will cause the value to be set at the high or low point of the range respectively."
+ ::= { dm3ConfigRectThresh 1 }
+
+
+dm3ConfigRectLowVoltThresh OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Rectifier low voltage threshold. If rectifier voltage is under threshold
+ a rectifier low voltage alarm will occur.
+
+ Values are represented in thousandths of Volts (mV).
+ Attempts to set the value above or below the acceptable range of the powerplant
+ will cause the value to be set at the high or low point of the range respectively."
+ ::= { dm3ConfigRectThresh 2 }
+
+dm3ConfigRectFailSafe OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Rectifier Fail Safe point. This OID represents the value sent to rectifier controllers
+ to use in the event of communications loss with the Master Controller or Master Controller
+ board failure.
+
+ Values are represented in thousandths of Volts (mV).
+ Attempts to set the value above or below the acceptable range of the powerplant
+ will cause the value to be set at the high or low point of the range respectively."
+ ::= { dm3ConfigRectThresh 3 }
+
+dm3ConfigRectFailComm OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Rectifier Communication Fail timeout. This OID represents the time interval in which there is no
+ communication between the rectifier and the master controller at which the rectifier will reset
+ all its values to default.
+
+ Values are represented in hundredths of Seconds.
+ Attempts to set the value above or below the acceptable range of the powerplant
+ will cause the value to be set at the high or low point of the range respectively."
+ ::= { dm3ConfigRectThresh 4 }
+
+-- the dm3ConfigRectAlarms group
+
+dm3ConfigRectHighVoltAlarm OBJECT-TYPE
+ SYNTAX INTEGER {
+ alarmIgnore (1),
+ alarmRelay1 (2),
+ alarmRelay2 (3),
+ alarmRelay3 (4),
+ alarmRelay4 (5),
+ alarmRelay5 (6),
+ alarmRelay6 (7),
+ alarmMinor (8),
+ alarmMajor (9)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "For the Rectifier High Voltage Alarm;
+ Setting this OID to alarmIgnore (1) results in the alarm condition being ignored.
+ Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an
+ alarm condition.
+ Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an
+ alarm condition.
+ Setting this OID to alarmMajor (9) causes the Major relay to be activated for an
+ alarm condition."
+
+ ::= { dm3ConfigRectAlarms 1 }
+
+dm3ConfigRectLowVoltAlarm OBJECT-TYPE
+ SYNTAX INTEGER {
+ alarmIgnore (1),
+ alarmRelay1 (2),
+ alarmRelay2 (3),
+ alarmRelay3 (4),
+ alarmRelay4 (5),
+ alarmRelay5 (6),
+ alarmRelay6 (7),
+ alarmMinor (8),
+ alarmMajor (9)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "For the Rectifier Low Voltage Alarm;
+ Setting this OID to alarmIgnore (1) results in the alarm condition being ignored.
+ Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an
+ alarm condition.
+ Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an
+ alarm condition.
+ Setting this OID to alarmMajor (9) causes the Major relay to be activated for an
+ alarm condition."
+
+ ::= { dm3ConfigRectAlarms 2 }
+
+dm3ConfigRectConfigAlarm OBJECT-TYPE
+ SYNTAX INTEGER {
+ alarmIgnore (1),
+ alarmRelay1 (2),
+ alarmRelay2 (3),
+ alarmRelay3 (4),
+ alarmRelay4 (5),
+ alarmRelay5 (6),
+ alarmRelay6 (7),
+ alarmMinor (8),
+ alarmMajor (9)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "This alarm is activated when a new rectifier is detected;
+ Setting this OID to alarmIgnore (1) results in the alarm condition being ignored.
+ Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an
+ alarm condition.
+ Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an
+ alarm condition.
+ Setting this OID to alarmMajor (9) causes the Major relay to be activated for an
+ alarm condition."
+
+ ::= { dm3ConfigRectAlarms 3 }
+
+dm3ConfigRect1ofNAlarm OBJECT-TYPE
+ SYNTAX INTEGER {
+ alarmIgnore (1),
+ alarmRelay1 (2),
+ alarmRelay2 (3),
+ alarmRelay3 (4),
+ alarmRelay4 (5),
+ alarmRelay5 (6),
+ alarmRelay6 (7),
+ alarmMinor (8),
+ alarmMajor (9)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "This setting indicates the action if ONE rectifier of a N+1 system has failed;
+ Setting this OID to alarmIgnore (1) results in the alarm condition being ignored.
+ Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an
+ alarm condition.
+ Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an
+ alarm condition.
+ Setting this OID to alarmMajor (9) causes the Major relay to be activated for an
+ alarm condition."
+
+ ::= { dm3ConfigRectAlarms 4 }
+
+dm3ConfigRect2ofNAlarm OBJECT-TYPE
+ SYNTAX INTEGER {
+ alarmIgnore (1),
+ alarmRelay1 (2),
+ alarmRelay2 (3),
+ alarmRelay3 (4),
+ alarmRelay4 (5),
+ alarmRelay5 (6),
+ alarmRelay6 (7),
+ alarmMinor (8),
+ alarmMajor (9)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "This setting indicates the action if TWO OR MORE rectifiers of a N+1 system have failed;
+ Setting this OID to alarmIgnore (1) results in the alarm condition being ignored.
+ Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an
+ alarm condition.
+ Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an
+ alarm condition.
+ Setting this OID to alarmMajor (9) causes the Major relay to be activated for an
+ alarm condition."
+
+ ::= { dm3ConfigRectAlarms 5 }
+
+dm3ConfigRectDiagAlarm OBJECT-TYPE
+ SYNTAX INTEGER {
+ alarmIgnore (1),
+ alarmRelay1 (2),
+ alarmRelay2 (3),
+ alarmRelay3 (4),
+ alarmRelay4 (5),
+ alarmRelay5 (6),
+ alarmRelay6 (7),
+ alarmMinor (8),
+ alarmMajor (9),
+ alarmNofN (10)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "For the Rectifier Controller Diagnostics Alarm;
+ Setting this OID to alarmIgnore (1) results in the alarm condition being ignored.
+ Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an
+ alarm condition.
+ Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an
+ alarm condition.
+ Setting this OID to alarmMajor (9) causes the Major relay to be activated for an
+ alarm condition.
+ Setting this OID to alarmNofN (10) causes the alarm specified in the dm3ConfigRect1ofNAlarm OID
+ to be activated if ONE rectifier fails in an N+1 system. It causes the alarm specified in the
+ dm3ConfigRect2ofNAlarm OID to be activated if TWO OR MORE rectifiers fail in an N+1 system."
+
+ ::= { dm3ConfigRectAlarms 6 }
+
+dm3ConfigRectImbalanceAlarm OBJECT-TYPE
+ SYNTAX INTEGER {
+ alarmIgnore (1),
+ alarmRelay1 (2),
+ alarmRelay2 (3),
+ alarmRelay3 (4),
+ alarmRelay4 (5),
+ alarmRelay5 (6),
+ alarmRelay6 (7),
+ alarmMinor (8),
+ alarmMajor (9)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "For the Rectifier Imbalance Alarm;
+ Setting this OID to alarmIgnore (1) results in the alarm condition being ignored.
+ Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an
+ alarm condition.
+ Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an
+ alarm condition.
+ Setting this OID to alarmMajor (9) causes the Major relay to be activated for an
+ alarm condition."
+
+ ::= { dm3ConfigRectAlarms 7 }
+
+dm3ConfigRectCurrLimitAlarm OBJECT-TYPE
+ SYNTAX INTEGER {
+ alarmIgnore (1),
+ alarmRelay1 (2),
+ alarmRelay2 (3),
+ alarmRelay3 (4),
+ alarmRelay4 (5),
+ alarmRelay5 (6),
+ alarmRelay6 (7),
+ alarmMinor (8),
+ alarmMajor (9),
+ alarmNofN (10)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "For the Rectifier Current Limit Alarm (indicating rectifier in the Current Limit state);
+ Setting this OID to alarmIgnore (1) results in the alarm condition being ignored.
+ Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an
+ alarm condition.
+ Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an
+ alarm condition.
+ Setting this OID to alarmMajor (9) causes the Major relay to be activated for an
+ alarm condition.
+ Setting this OID to alarmNofN (10) causes the alarm specified in the dm3ConfigRect1ofNAlarm OID
+ to be activated if ONE rectifier fails in an N+1 system. It causes the alarm specified in the
+ dm3ConfigRect2ofNAlarm OID to be activated if TWO OR MORE rectifiers fail in an N+1 system."
+
+ ::= { dm3ConfigRectAlarms 8 }
+
+dm3ConfigRectStandbyAlarm OBJECT-TYPE
+ SYNTAX INTEGER {
+ alarmIgnore (1),
+ alarmRelay1 (2),
+ alarmRelay2 (3),
+ alarmRelay3 (4),
+ alarmRelay4 (5),
+ alarmRelay5 (6),
+ alarmRelay6 (7),
+ alarmMinor (8),
+ alarmMajor (9),
+ alarmNofN (10)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "For the Rectifier Standby Alarm (indicating output DC has been turned off);
+ Setting this OID to alarmIgnore (1) results in the alarm condition being ignored.
+ Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an
+ alarm condition.
+ Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an
+ alarm condition.
+ Setting this OID to alarmMajor (9) causes the Major relay to be activated for an
+ alarm condition.
+ Setting this OID to alarmNofN (10) causes the alarm specified in the dm3ConfigRect1ofNAlarm OID
+ to be activated if ONE rectifier fails in an N+1 system. It causes the alarm specified in the
+ dm3ConfigRect2ofNAlarm OID to be activated if TWO OR MORE rectifiers fail in an N+1 system."
+
+ ::= { dm3ConfigRectAlarms 9 }
+
+dm3ConfigRectFanFailAlarm OBJECT-TYPE
+ SYNTAX INTEGER {
+ alarmIgnore (1),
+ alarmRelay1 (2),
+ alarmRelay2 (3),
+ alarmRelay3 (4),
+ alarmRelay4 (5),
+ alarmRelay5 (6),
+ alarmRelay6 (7),
+ alarmMinor (8),
+ alarmMajor (9),
+ alarmNofN (10)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "For the Rectifier Fan Fail Alarm;
+ Setting this OID to alarmIgnore (1) results in the alarm condition being ignored.
+ Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an
+ alarm condition.
+ Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an
+ alarm condition.
+ Setting this OID to alarmMajor (9) causes the Major relay to be activated for an
+ alarm condition.
+ Setting this OID to alarmNofN (10) causes the alarm specified in the dm3ConfigRect1ofNAlarm OID
+ to be activated if ONE rectifier fails in an N+1 system. It causes the alarm specified in the
+ dm3ConfigRect2ofNAlarm OID to be activated if TWO OR MORE rectifiers fail in an N+1 system."
+
+ ::= { dm3ConfigRectAlarms 10 }
+
+dm3ConfigRectFailAlarm OBJECT-TYPE
+ SYNTAX INTEGER {
+ alarmIgnore (1),
+ alarmRelay1 (2),
+ alarmRelay2 (3),
+ alarmRelay3 (4),
+ alarmRelay4 (5),
+ alarmRelay5 (6),
+ alarmRelay6 (7),
+ alarmMinor (8),
+ alarmMajor (9),
+ alarmNofN (10)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "For the Rectifier Fail Alarm;
+ Setting this OID to alarmIgnore (1) results in the alarm condition being ignored.
+ Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an
+ alarm condition.
+ Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an
+ alarm condition.
+ Setting this OID to alarmMajor (9) causes the Major relay to be activated for an
+ alarm condition.
+ Setting this OID to alarmNofN (10) causes the alarm specified in the dm3ConfigRect1ofNAlarm OID
+ to be activated if ONE rectifier fails in an N+1 system. It causes the alarm specified in the
+ dm3ConfigRect2ofNAlarm OID to be activated if TWO OR MORE rectifiers fail in an N+1 system."
+
+ ::= { dm3ConfigRectAlarms 11 }
+
+dm3ConfigRectHwVoltAlarm OBJECT-TYPE
+ SYNTAX INTEGER {
+ alarmIgnore (1),
+ alarmRelay1 (2),
+ alarmRelay2 (3),
+ alarmRelay3 (4),
+ alarmRelay4 (5),
+ alarmRelay5 (6),
+ alarmRelay6 (7),
+ alarmMinor (8),
+ alarmMajor (9)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "For the Rectifier Hardware Voltage Alarm (indicating voltage outside realistic limits,
+ or a possible measurement fault);
+ Setting this OID to alarmIgnore (1) results in the alarm condition being ignored.
+ Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an
+ alarm condition.
+ Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an
+ alarm condition.
+ Setting this OID to alarmMajor (9) causes the Major relay to be activated for an
+ alarm condition."
+
+ ::= { dm3ConfigRectAlarms 12 }
+
+
+-- the dm3ConfigConvThresh group
+
+dm3ConfigConvHighVoltThresh OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Converter high voltage threshold. If converter voltage exceeds threshold
+ a converter high voltage alarm will occur.
+
+ Values are represented in thousandths of Volts (mV).
+ Attempts to set the value above or below the acceptable range of the powerplant
+ will cause the value to be set at the high or low point of the range respectively."
+
+ ::= { dm3ConfigConvThresh 1 }
+
+dm3ConfigConvLowVoltThresh OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Converter low voltage threshold. If converter voltage exceeds threshold
+ a converter low voltage alarm will occur.
+
+ Values are represented in thousandths of Volts (mV).
+ Attempts to set the value above or below the acceptable range of the powerplant
+ will cause the value to be set at the high or low point of the range respectively."
+ ::= { dm3ConfigConvThresh 2 }
+
+dm3ConfigConvFailSafe OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Converter Fail Safe point. This OID represents the value sent to converter controllers
+ to use in the event of communications loss with the Master Controller or Master Controller
+ board failure.
+
+ Values are represented in thousandths of Volts (mV).
+ Attempts to set the value above or below the acceptable range of the powerplant
+ will cause the value to be set at the high or low point of the range respectively."
+ ::= { dm3ConfigConvThresh 3 }
+
+dm3ConfigConvSetPoint OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Converter Set point. This OID represents the initial set point used in the
+ voltage control loop.
+
+ Units are thousandths of Volts (mV).
+ Attempts to set the value above or below the acceptable range of the powerplant
+ will cause the value to be set at the high or low point of the range respectively."
+ ::= { dm3ConfigConvThresh 4 }
+
+dm3ConfigConvFailMax OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Converter Fail Maximum limit. This OID represents the value sent to the converter
+ controllers to define the maximum set point allowed.
+
+ Units are thousandths of Volts (mV).
+ Attempts to set the value above or below the acceptable range of the powerplant
+ will cause the value to be set at the high or low point of the range respectively."
+ ::= { dm3ConfigConvThresh 5 }
+
+dm3ConfigConvFailMin OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Converter Fail Minimum limit. This OID represents the value sent to the converter
+ controllers to define the minimum set point allowed.
+
+ Units are thousandths of Volts (mV).
+ Attempts to set the value above or below the acceptable range of the powerplant
+ will cause the value to be set at the high or low point of the range respectively."
+ ::= { dm3ConfigConvThresh 6 }
+
+dm3ConfigConvFailComm OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Converter Communication Fail timeout. This OID represents the time interval in which there is no
+ communication between the converter and the master controller at which the converter will reset
+ all its values to default.
+
+ Values are represented in hundredths of Seconds.
+ Attempts to set the value above or below the acceptable range of the powerplant
+ will cause the value to be set at the high or low point of the range respectively."
+ ::= { dm3ConfigConvThresh 7 }
+
+-- the dm3ConfigConvAlarms group
+dm3ConfigConvHighVoltAlarm OBJECT-TYPE
+ SYNTAX INTEGER {
+ alarmIgnore (1),
+ alarmRelay1 (2),
+ alarmRelay2 (3),
+ alarmRelay3 (4),
+ alarmRelay4 (5),
+ alarmRelay5 (6),
+ alarmRelay6 (7),
+ alarmMinor (8),
+ alarmMajor (9)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "For the Converter High Voltage Alarm;
+ Setting this OID to alarmIgnore (1) results in the alarm condition being ignored.
+ Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an
+ alarm condition.
+ Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an
+ alarm condition.
+ Setting this OID to alarmMajor (9) causes the Major relay to be activated for an
+ alarm condition."
+
+ ::= { dm3ConfigConvAlarms 1 }
+
+dm3ConfigConvLowVoltAlarm OBJECT-TYPE
+ SYNTAX INTEGER {
+ alarmIgnore (1),
+ alarmRelay1 (2),
+ alarmRelay2 (3),
+ alarmRelay3 (4),
+ alarmRelay4 (5),
+ alarmRelay5 (6),
+ alarmRelay6 (7),
+ alarmMinor (8),
+ alarmMajor (9)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "For the Converter Low Voltage Alarm;
+ Setting this OID to alarmIgnore (1) results in the alarm condition being ignored.
+ Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an
+ alarm condition.
+ Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an
+ alarm condition.
+ Setting this OID to alarmMajor (9) causes the Major relay to be activated for an
+ alarm condition."
+
+ ::= { dm3ConfigConvAlarms 2 }
+
+dm3ConfigConvConfigAlarm OBJECT-TYPE
+ SYNTAX INTEGER {
+ alarmIgnore (1),
+ alarmRelay1 (2),
+ alarmRelay2 (3),
+ alarmRelay3 (4),
+ alarmRelay4 (5),
+ alarmRelay5 (6),
+ alarmRelay6 (7),
+ alarmMinor (8),
+ alarmMajor (9)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "For the Converter Configuration Alarm (indicating a new converter has been detected);
+ Setting this OID to alarmIgnore (1) results in the alarm condition being ignored.
+ Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an
+ alarm condition.
+ Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an
+ alarm condition.
+ Setting this OID to alarmMajor (9) causes the Major relay to be activated for an
+ alarm condition."
+
+ ::= { dm3ConfigConvAlarms 3 }
+
+dm3ConfigConv1ofNAlarm OBJECT-TYPE
+ SYNTAX INTEGER {
+ alarmIgnore (1),
+ alarmRelay1 (2),
+ alarmRelay2 (3),
+ alarmRelay3 (4),
+ alarmRelay4 (5),
+ alarmRelay5 (6),
+ alarmRelay6 (7),
+ alarmMinor (8),
+ alarmMajor (9)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "For the Converter 1ofN Alarm (indicating action if ONE converter of a N+1 system has failed);
+ Setting this OID to alarmIgnore (1) results in the alarm condition being ignored.
+ Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an
+ alarm condition.
+ Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an
+ alarm condition.
+ Setting this OID to alarmMajor (9) causes the Major relay to be activated for an
+ alarm condition."
+
+ ::= { dm3ConfigConvAlarms 4 }
+
+dm3ConfigConv2ofNAlarm OBJECT-TYPE
+ SYNTAX INTEGER {
+ alarmIgnore (1),
+ alarmRelay1 (2),
+ alarmRelay2 (3),
+ alarmRelay3 (4),
+ alarmRelay4 (5),
+ alarmRelay5 (6),
+ alarmRelay6 (7),
+ alarmMinor (8),
+ alarmMajor (9)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "For the Converter 2ofN Alarm (indicating action if TWO OR MORE converters of a N+1 system has failed);
+ Setting this OID to alarmIgnore (1) results in the alarm condition being ignored.
+ Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an
+ alarm condition.
+ Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an
+ alarm condition.
+ Setting this OID to alarmMajor (9) causes the Major relay to be activated for an
+ alarm condition."
+
+ ::= { dm3ConfigConvAlarms 5 }
+
+dm3ConfigConvDiagAlarm OBJECT-TYPE
+ SYNTAX INTEGER {
+ alarmIgnore (1),
+ alarmRelay1 (2),
+ alarmRelay2 (3),
+ alarmRelay3 (4),
+ alarmRelay4 (5),
+ alarmRelay5 (6),
+ alarmRelay6 (7),
+ alarmMinor (8),
+ alarmMajor (9),
+ alarmNofN (10)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "For the Converter Diagnostics Alarm;
+ Setting this OID to alarmIgnore (1) results in the alarm condition being ignored.
+ Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an
+ alarm condition.
+ Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an
+ alarm condition.
+ Setting this OID to alarmMajor (9) causes the Major relay to be activated for an
+ alarm condition.
+ Setting this OID to alarmNofN (10) causes the alarm specified in the dm3ConfigConv1ofNAlarm OID
+ to be activated if ONE converter fails in an N+1 system. It causes the alarm specified in the
+ dm3ConfigConv2ofNAlarm OID to be activated if TWO OR MORE converters fail in an N+1 system."
+
+ ::= { dm3ConfigConvAlarms 6 }
+
+dm3ConfigConvImbalanceAlarm OBJECT-TYPE
+ SYNTAX INTEGER {
+ alarmIgnore (1),
+ alarmRelay1 (2),
+ alarmRelay2 (3),
+ alarmRelay3 (4),
+ alarmRelay4 (5),
+ alarmRelay5 (6),
+ alarmRelay6 (7),
+ alarmMinor (8),
+ alarmMajor (9),
+ alarmNofN (10)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "For the Converter Imbalance Alarm;
+ Setting this OID to alarmIgnore (1) results in the alarm condition being ignored.
+ Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an
+ alarm condition.
+ Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an
+ alarm condition.
+ Setting this OID to alarmMajor (9) causes the Major relay to be activated for an
+ alarm condition.
+ Setting this OID to alarmNofN (10) causes the alarm specified in the dm3ConfigConv1ofNAlarm OID
+ to be activated if ONE converter fails in an N+1 system. It causes the alarm specified in the
+ dm3ConfigConv2ofNAlarm OID to be activated if TWO OR MORE converters fail in an N+1 system."
+
+ ::= { dm3ConfigConvAlarms 7 }
+
+dm3ConfigConvCurrLimitAlarm OBJECT-TYPE
+ SYNTAX INTEGER {
+ alarmIgnore (1),
+ alarmRelay1 (2),
+ alarmRelay2 (3),
+ alarmRelay3 (4),
+ alarmRelay4 (5),
+ alarmRelay5 (6),
+ alarmRelay6 (7),
+ alarmMinor (8),
+ alarmMajor (9),
+ alarmNofN (10)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "For the Converter Current Limit Alarm (indicating the converter is in the Current Limit state);
+ Setting this OID to alarmIgnore (1) results in the alarm condition being ignored.
+ Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an
+ alarm condition.
+ Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an
+ alarm condition.
+ Setting this OID to alarmMajor (9) causes the Major relay to be activated for an
+ alarm condition.
+ Setting this OID to alarmNofN (10) causes the alarm specified in the dm3ConfigConv1ofNAlarm OID
+ to be activated if ONE converter fails in an N+1 system. It causes the alarm specified in the
+ dm3ConfigConv2ofNAlarm OID to be activated if TWO OR MORE converters fail in an N+1 system."
+
+ ::= { dm3ConfigConvAlarms 8 }
+
+dm3ConfigConvStandbyAlarm OBJECT-TYPE
+ SYNTAX INTEGER {
+ alarmIgnore (1),
+ alarmRelay1 (2),
+ alarmRelay2 (3),
+ alarmRelay3 (4),
+ alarmRelay4 (5),
+ alarmRelay5 (6),
+ alarmRelay6 (7),
+ alarmMinor (8),
+ alarmMajor (9),
+ alarmNofN (10)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "For the Converter Standby Alarm (indicating the converter is in the Standby state);
+ Setting this OID to alarmIgnore (1) results in the alarm condition being ignored.
+ Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an
+ alarm condition.
+ Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an
+ alarm condition.
+ Setting this OID to alarmMajor (9) causes the Major relay to be activated for an
+ alarm condition.
+ Setting this OID to alarmNofN (10) causes the alarm specified in the dm3ConfigConv1ofNAlarm OID
+ to be activated if ONE converter fails in an N+1 system. It causes the alarm specified in the
+ dm3ConfigConv2ofNAlarm OID to be activated if TWO OR MORE converters fail in an N+1 system."
+
+ ::= { dm3ConfigConvAlarms 9 }
+
+dm3ConfigConvFanFailAlarm OBJECT-TYPE
+ SYNTAX INTEGER {
+ alarmIgnore (1),
+ alarmRelay1 (2),
+ alarmRelay2 (3),
+ alarmRelay3 (4),
+ alarmRelay4 (5),
+ alarmRelay5 (6),
+ alarmRelay6 (7),
+ alarmMinor (8),
+ alarmMajor (9),
+ alarmNofN (10)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "For the Converter Fan Fail Alarm;
+ Setting this OID to alarmIgnore (1) results in the alarm condition being ignored.
+ Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an
+ alarm condition.
+ Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an
+ alarm condition.
+ Setting this OID to alarmMajor (9) causes the Major relay to be activated for an
+ alarm condition.
+ Setting this OID to alarmNofN (10) causes the alarm specified in the dm3ConfigConv1ofNAlarm OID
+ to be activated if ONE converter fails in an N+1 system. It causes the alarm specified in the
+ dm3ConfigConv2ofNAlarm OID to be activated if TWO OR MORE converters fail in an N+1 system."
+
+ ::= { dm3ConfigConvAlarms 10 }
+
+dm3ConfigConvFailAlarm OBJECT-TYPE
+ SYNTAX INTEGER {
+ alarmIgnore (1),
+ alarmRelay1 (2),
+ alarmRelay2 (3),
+ alarmRelay3 (4),
+ alarmRelay4 (5),
+ alarmRelay5 (6),
+ alarmRelay6 (7),
+ alarmMinor (8),
+ alarmMajor (9),
+ alarmNofN (10)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "For the Converter Fail Alarm;
+ Setting this OID to alarmIgnore (1) results in the alarm condition being ignored.
+ Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an
+ alarm condition.
+ Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an
+ alarm condition.
+ Setting this OID to alarmMajor (9) causes the Major relay to be activated for an
+ alarm condition.
+ Setting this OID to alarmNofN (10) causes the alarm specified in the dm3ConfigConv1ofNAlarm OID
+ to be activated if ONE converter fails in an N+1 system. It causes the alarm specified in the
+ dm3ConfigConv2ofNAlarm OID to be activated if TWO OR MORE converters fail in an N+1 system."
+
+ ::= { dm3ConfigConvAlarms 11 }
+
+dm3ConfigConvHwVoltAlarm OBJECT-TYPE
+ SYNTAX INTEGER {
+ alarmIgnore (1),
+ alarmRelay1 (2),
+ alarmRelay2 (3),
+ alarmRelay3 (4),
+ alarmRelay4 (5),
+ alarmRelay5 (6),
+ alarmRelay6 (7),
+ alarmMinor (8),
+ alarmMajor (9),
+ alarmNofN (10)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "For the Converter Voltage Alarm (indicating voltage outside realistic limits, or a
+ possible measurement fault);
+ Setting this OID to alarmIgnore (1) results in the alarm condition being ignored.
+ Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an
+ alarm condition.
+ Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an
+ alarm condition.
+ Setting this OID to alarmMajor (9) causes the Major relay to be activated for an
+ alarm condition.
+ Setting this OID to alarmNofN (10) causes the alarm specified in the dm3ConfigConv1ofNAlarm OID
+ to be activated if ONE converter fails in an N+1 system. It causes the alarm specified in the
+ dm3ConfigConv2ofNAlarm OID to be activated if TWO OR MORE converters fail in an N+1 system."
+
+ ::= { dm3ConfigConvAlarms 12 }
+
+
+-- the dm3ConfigOutputRelays group
+
+dm3ConfigOutRlyTableSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of DC powerplant Output Relays controllable
+ by this IP address."
+ ::= { dm3ConfigOutputRelays 1 }
+
+dm3ConfigOutRlyTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ConfigOutRlyEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for accessing settings of the Output Relays. The number of
+ entries is contained in the dm3ConfigOutRlyTableSize OID."
+ ::= { dm3ConfigOutputRelays 2 }
+
+dm3ConfigOutRlyEntry OBJECT-TYPE
+ SYNTAX ConfigOutRlyEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The output relay to configure."
+ INDEX { dm3ConfigOutRlyIndex }
+ ::= { dm3ConfigOutRlyTable 1 }
+
+ConfigOutRlyEntry ::=
+ SEQUENCE {
+ dm3ConfigOutRlyIndex INTEGER,
+ dm3ConfigOutRlyName DisplayString,
+ dm3ConfigOutRlyDelay INTEGER,
+ dm3ConfigOutRlyAlarm INTEGER
+ }
+
+dm3ConfigOutRlyIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the DC powerplant output relay."
+ ::= { dm3ConfigOutRlyEntry 1 }
+
+dm3ConfigOutRlyName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The name of the output relay. The maximum value is 16 characters."
+ ::= { dm3ConfigOutRlyEntry 2 }
+
+dm3ConfigOutRlyDelay OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Output Relay Delay. This OID represents the time delay from the initiation of an
+ output relay action to when the output relay action does occur. If the alarm condition
+ disappears before the end of the delay, no action will occur. Delay for Major
+ and Minor alarms is not configurable and is always set to 0.
+
+ Values are represented in hundredths of seconds.
+ Attempts to set the value above or below the acceptable range of the powerplant
+ will cause the value to be set at the high or low point of the range respectively."
+ ::= { dm3ConfigOutRlyEntry 3 }
+
+dm3ConfigOutRlyAlarm OBJECT-TYPE
+ SYNTAX INTEGER {
+ alarmIgnore (1),
+ alarmRelay1 (2),
+ alarmRelay2 (3),
+ alarmRelay3 (4),
+ alarmRelay4 (5),
+ alarmRelay5 (6),
+ alarmRelay6 (7),
+ alarmMinor (8),
+ alarmMajor (9)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Output Relay Alarm. This setting indicates what action to perform in the event of
+ an output relay alarm condition;
+ Setting this OID to alarmIgnore (1) results in the alarm condition being ignored.
+ Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an
+ alarm condition.
+ Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an
+ alarm condition.
+ Setting this OID to alarmMajor (9) causes the Major relay to be activated for an
+ alarm condition.
+
+ Relay Alarm for Major and Minor alarms is not configurable and is always set to
+ alarmMajor and alarmMinor respectively."
+
+ ::= { dm3ConfigOutRlyEntry 4 }
+
+
+-- the dm3ConfigInputRelays group
+
+dm3ConfigInRlyTableSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of DC powerplant Input Relays controllable
+ by this IP address."
+ ::= { dm3ConfigInputRelays 1 }
+
+dm3ConfigInRlyTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ConfigInRlyEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for accessing settings of the Input Relays. The number of
+ entries is contained in the dm3ConfigInRlyTableSize OID."
+ ::= { dm3ConfigInputRelays 2 }
+
+dm3ConfigInRlyEntry OBJECT-TYPE
+ SYNTAX ConfigInRlyEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The input relay to configure."
+ INDEX { dm3ConfigInRlyIndex }
+ ::= { dm3ConfigInRlyTable 1 }
+
+ConfigInRlyEntry ::=
+ SEQUENCE {
+ dm3ConfigInRlyIndex INTEGER,
+ dm3ConfigInRlyName DisplayString,
+ dm3ConfigInRlyDelay INTEGER,
+ dm3ConfigInRlyAlarm INTEGER
+ }
+
+dm3ConfigInRlyIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the DC powerplant input relay."
+ ::= { dm3ConfigInRlyEntry 1 }
+
+dm3ConfigInRlyName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The name of the input relay. The maximum value is 16 characters."
+
+ ::= { dm3ConfigInRlyEntry 2 }
+
+dm3ConfigInRlyDelay OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Input Relay Delay. This OID represents the time delay from the initiation of an
+ input relay action to when the input relay action does occur. If the alarm condition
+ disappears before the end of the delay, no action will occur.
+
+ Values are represented in hundredths of seconds.
+
+ Attempts to set the value above or below the acceptable range of the powerplant
+ will cause the value to be set at the high or low point of the range respectively."
+ ::= { dm3ConfigInRlyEntry 3 }
+
+dm3ConfigInRlyAlarm OBJECT-TYPE
+ SYNTAX INTEGER {
+ alarmIgnore (1),
+ alarmRelay1 (2),
+ alarmRelay2 (3),
+ alarmRelay3 (4),
+ alarmRelay4 (5),
+ alarmRelay5 (6),
+ alarmRelay6 (7),
+ alarmMinor (8),
+ alarmMajor (9)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Input Relay Alarm. This setting indicates what action to perform in the event of
+ an input relay alarm condition;
+ Setting this OID to alarmIgnore (1) results in the alarm condition being ignored.
+ Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an
+ alarm condition.
+ Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an
+ alarm condition.
+ Setting this OID to alarmMajor (9) causes the Major relay to be activated for an
+ alarm condition."
+
+ ::= { dm3ConfigInRlyEntry 4 }
+
+-- the dm3ConfigBreakers group
+
+dm3ConfigBreakersTableSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of DC powerplant circuit breakers controllable
+ by this IP address."
+ ::= { dm3ConfigBreakers 1 }
+
+dm3ConfigBreakersTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ConfigBreakersEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for accessing settings of the circuit breakers. The number of
+ entries is contained in the dm3ConfigBreakersTableSize OID."
+ ::= { dm3ConfigBreakers 2 }
+
+dm3ConfigBreakersEntry OBJECT-TYPE
+ SYNTAX ConfigBreakersEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The circuit breaker to configure."
+ INDEX { dm3ConfigBreakersIndex }
+ ::= { dm3ConfigBreakersTable 1 }
+
+ConfigBreakersEntry ::=
+ SEQUENCE {
+ dm3ConfigBreakersIndex INTEGER,
+ dm3ConfigBreakersName DisplayString,
+ dm3ConfigBreakersAlarm INTEGER
+ }
+
+dm3ConfigBreakersIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the DC powerplant circuit breaker."
+ ::= { dm3ConfigBreakersEntry 1 }
+
+dm3ConfigBreakersName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The name of the circuit breaker. The maximum value is 16 characters."
+ ::= { dm3ConfigBreakersEntry 2 }
+
+dm3ConfigBreakersAlarm OBJECT-TYPE
+ SYNTAX INTEGER {
+ alarmIgnore (1),
+ alarmRelay1 (2),
+ alarmRelay2 (3),
+ alarmRelay3 (4),
+ alarmRelay4 (5),
+ alarmRelay5 (6),
+ alarmRelay6 (7),
+ alarmMinor (8),
+ alarmMajor (9)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Circuit Breaker Alarm. This setting indicates what action to perform in the event of
+ a circuit breaker alarm condition;
+ Setting this OID to alarmIgnore (1) results in the alarm condition being ignored.
+ Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an
+ alarm condition.
+ Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an
+ alarm condition.
+ Setting this OID to alarmMajor (9) causes the Major relay to be activated for an
+ alarm condition."
+
+ ::= { dm3ConfigBreakersEntry 3 }
+
+-- the dm3ConfigFuses group
+
+dm3ConfigFusesTableSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of DC powerplant Fuses controllable
+ by this IP address."
+ ::= { dm3ConfigFuses 1 }
+
+dm3ConfigFusesTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ConfigFusesEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for accessing settings of the Fuses. The number of
+ entries is contained in the dm3ConfigFusesTableSize OID."
+ ::= { dm3ConfigFuses 2 }
+
+dm3ConfigFusesEntry OBJECT-TYPE
+ SYNTAX ConfigFusesEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The fuse to configure."
+ INDEX { dm3ConfigFusesIndex }
+ ::= { dm3ConfigFusesTable 1 }
+
+ConfigFusesEntry ::=
+ SEQUENCE {
+ dm3ConfigFusesIndex INTEGER,
+ dm3ConfigFusesName DisplayString,
+ dm3ConfigFusesAlarm INTEGER
+ }
+
+dm3ConfigFusesIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the DC powerplant fuse."
+ ::= { dm3ConfigFusesEntry 1 }
+
+dm3ConfigFusesName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The name of the fuse. The maximum value is 16 characters."
+ ::= { dm3ConfigFusesEntry 2 }
+
+dm3ConfigFusesAlarm OBJECT-TYPE
+ SYNTAX INTEGER {
+ alarmIgnore (1),
+ alarmRelay1 (2),
+ alarmRelay2 (3),
+ alarmRelay3 (4),
+ alarmRelay4 (5),
+ alarmRelay5 (6),
+ alarmRelay6 (7),
+ alarmMinor (8),
+ alarmMajor (9)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Fuses Alarm. This setting indicates what action to perform in the event of
+ a Fuse alarm condition;
+ Setting this OID to alarmIgnore (1) results in the alarm condition being ignored.
+ Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an
+ alarm condition.
+ Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an
+ alarm condition.
+ Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an
+ alarm condition.
+ Setting this OID to alarmMajor (9) causes the Major relay to be activated for an
+ alarm condition."
+
+ ::= { dm3ConfigFusesEntry 3 }
+
+-- the dm3StatusSystem group
+
+dm3StatusSystemTemp OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "System temperature based on sensor on Master Controller PCB.
+
+ Values are represented in thousandths of a degree.
+ Units are displayed in the scale shown in
+ the 'dm3StatusSysTempUnits' OID (Celsius or Fahrenheit)."
+
+ ::= { dm3StatusSystem 1 }
+
+dm3StatusSystemStart OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Time stamp at DC powerplant initialization.
+ The time is represented as MMM,DD,YYYY,HH:MM:SS."
+ ::= { dm3StatusSystem 2 }
+
+dm3StatusSysRemoteAccess OBJECT-TYPE
+ SYNTAX INTEGER {
+ accessEnabled (1),
+ accessDisabled (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Remote Access indicator
+ This setting indicates if configuration (write) access to the powerplant is enabled or
+ disabled at the powerplant level.
+ This value will be accessEnabled (1) if remote configuration is enabled, and
+ accessDisabled (2) if remote configuration is disabled."
+ ::= { dm3StatusSystem 3 }
+
+dm3StatusSysSecurityLevel OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This variable shows the current active security access level of controller. This
+ can only be changed directly from the front panel."
+ ::= { dm3StatusSystem 4 }
+
+dm3StatusSysTempSanity OBJECT-TYPE
+ SYNTAX INTEGER{
+ saneYES (1),
+ saneNO (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "System temperature sanity indicator. Indicates if the system temperature is
+ reasonable. Reasonable is defined based on powerplant type. A value of saneYes (1)
+ indicates temperature is reasonable, a value of saneNo (2) indicates it is not."
+ ::= { dm3StatusSystem 5 }
+
+dm3StatusSysAlarmState OBJECT-TYPE
+ SYNTAX INTEGER{
+ alarmMinor (1),
+ alarmMajor (2),
+ alarmBoth (3),
+ alarmNone (4)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "System Alarm State. Reflects the alarm status of the overall DC system.
+ If a minor alarm is present, the value will be alarmMinor(1).
+ If a major alarm is present, the value will be alarmMajor(2).
+ If both minor and a major alarm is present, the value will be alarmBoth(3).
+ If no alarm is present, the value will be alarmNone(4)."
+ ::= { dm3StatusSystem 6 }
+
+dm3StatusSysTempUnits OBJECT-TYPE
+ SYNTAX INTEGER {
+ celsius(1),
+ fahrenheit(2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The temperature scale used to display the temperature
+ in the DC system, Celsius(1) or Fahrenheit(2).
+ This setting is based on the system preferences
+ configuration in the agent."
+ ::= { dm3StatusSystem 7 }
+
+
+-- the dm3StatusAlarms group
+
+dm3StatusAlarmsTableSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of DC powerplant alarms viewable
+ by this IP address."
+ ::= { dm3StatusAlarms 1 }
+
+dm3StatusAlarmsTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF StatusAlarmsEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for accessing system alarms. The number of
+ entries is contained in the dm3StatusAlarmsTableSize OID."
+ ::= { dm3StatusAlarms 2 }
+
+dm3StatusAlarmsEntry OBJECT-TYPE
+ SYNTAX StatusAlarmsEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The alarm to display."
+ INDEX { dm3StatusAlarmsIndex }
+ ::= { dm3StatusAlarmsTable 1 }
+
+StatusAlarmsEntry ::=
+ SEQUENCE {
+ dm3StatusAlarmsIndex INTEGER,
+ dm3StatusAlarmsText DisplayString
+ }
+
+dm3StatusAlarmsIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index of the system alarm."
+ ::= { dm3StatusAlarmsEntry 1 }
+
+dm3StatusAlarmsText OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The 16 character text describing the active alarm condition."
+ ::= { dm3StatusAlarmsEntry 2 }
+
+-- the dm3StatusBattery group
+
+dm3StatusBattCurrent OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Battery Current: This OID shows the battery current in thousandths of Amps (mA)."
+ ::= { dm3StatusBattery 1 }
+
+dm3StatusBattTemp OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Battery Temperature:
+
+ Values are represented in thousandths of a degree.
+ Units are displayed in the scale shown in
+ the 'dm3StatusSysTempUnits' OID (Celsius or Fahrenheit)."
+
+ ::= { dm3StatusBattery 2 }
+
+dm3StatusBattCurrentSanity OBJECT-TYPE
+ SYNTAX INTEGER{
+ saneYES (1),
+ saneNO (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Battery current sanity indicator. Indicates if the battery current is
+ reasonable. Reasonable is defined based on powerplant type. A value of saneYes (1)
+ indicates current is reasonable, a value of saneNo (2) indicates it is not."
+ ::= { dm3StatusBattery 3 }
+
+dm3StatusBattTempSanity OBJECT-TYPE
+ SYNTAX INTEGER{
+ saneYES (1),
+ saneNO (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Battery temperature sanity indicator. Indicates if the battery temperature is
+ reasonable. Reasonable is defined based on powerplant type. A value of saneYes (1)
+ indicates temperature is reasonable, a value of saneNo (2) indicates it is not."
+ ::= { dm3StatusBattery 4 }
+
+-- the dm3StatusOEM group
+
+dm3StatusOEMrectOffset OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This OID shows the rectifier offset value in thousandths of Volts (mV)."
+ ::= { dm3StatusOEM 1 }
+
+dm3StatusOEMrectGain OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This OID shows the rectifier gain value in thousandths of Volts (mV/V)."
+ ::= { dm3StatusOEM 2 }
+
+dm3StatusOEMconvOffset OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This OID shows the converter offset value in thousandths of Volts (mV)."
+ ::= { dm3StatusOEM 3 }
+
+dm3StatusOEMconvGain OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This OID shows the converter gain value in thousandths of Volts (mV/V)."
+ ::= { dm3StatusOEM 4 }
+
+dm3StatusOEMshuntOffset OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This OID shows the shunt offset value in thousandths of Amps (mA)."
+ ::= { dm3StatusOEM 5 }
+
+dm3StatusOEMshuntGain OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This OID shows the shunt gain value in thousandths of Amps (mA/A)."
+ ::= { dm3StatusOEM 6 }
+
+-- the dm3StatusLVD group
+
+dm3StatusLVDTableSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of DC powerplant LVDs viewable
+ by this IP address."
+ ::= { dm3StatusLVD 1 }
+
+dm3StatusLVDTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF StatusLVDEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for accessing settings of the LVDs. The number of
+ entries is contained in the dm3StatusLVDTableSize OID."
+ ::= { dm3StatusLVD 2 }
+
+dm3StatusLVDEntry OBJECT-TYPE
+ SYNTAX StatusLVDEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The LVD to gather status from."
+ INDEX { dm3StatusLVDIndex }
+ ::= { dm3StatusLVDTable 1 }
+
+StatusLVDEntry ::=
+ SEQUENCE {
+ dm3StatusLVDIndex INTEGER,
+ dm3StatusLVDName DisplayString,
+ dm3StatusLVDState INTEGER,
+ dm3StatusLVDHwFault INTEGER
+ }
+
+dm3StatusLVDIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the DC powerplant LVD."
+ ::= { dm3StatusLVDEntry 1 }
+
+dm3StatusLVDName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The name of the LVD. The maximum size is
+ 16 characters. The name is set by using the
+ dm3ConfigLVDName OID.
+ This OID is provided for informational purposes only."
+ ::= { dm3StatusLVDEntry 2 }
+
+dm3StatusLVDState OBJECT-TYPE
+ SYNTAX INTEGER {
+ statusClosed (1),
+ statusOpened (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this OID will return statusClosed (1) if the LVD is closed.
+ statusOpened (2) will be returned if the LVD is opened."
+ ::= { dm3StatusLVDEntry 3 }
+
+dm3StatusLVDHwFault OBJECT-TYPE
+ SYNTAX INTEGER {
+ statusFault (1),
+ statusNofault (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this OID will return statusFault (1) if the LVD is faulted.
+ statusNofault (2) will be returned if the LVD is not faulted."
+ ::= { dm3StatusLVDEntry 4 }
+
+-- the dm3StatusRectifier group
+
+dm3StatusRectTableSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of DC powerplant rectifiers viewable
+ by this IP address."
+ ::= { dm3StatusRectifier 1 }
+
+dm3StatusRectTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF StatusRectEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for accessing settings of the rectifiers. The number of
+ entries is contained in the dm3StatusRectTableSize OID."
+ ::= { dm3StatusRectifier 2 }
+
+dm3StatusRectEntry OBJECT-TYPE
+ SYNTAX StatusRectEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The rectifier to gather status from."
+ INDEX { dm3StatusRectIndex }
+ ::= { dm3StatusRectTable 1 }
+
+StatusRectEntry ::=
+ SEQUENCE {
+ dm3StatusRectIndex INTEGER,
+ dm3StatusRectID INTEGER,
+ dm3StatusRectDesc DisplayString,
+ dm3StatusRectCurrent INTEGER,
+ dm3StatusRectCurrentLimit INTEGER,
+ dm3StatusRectStandby INTEGER,
+ dm3StatusRectFanFail INTEGER,
+ dm3StatusRectFail INTEGER,
+ dm3StatusRectDevType INTEGER,
+ dm3StatusRectPhyAddr INTEGER,
+ dm3StatusRectCfg INTEGER,
+ dm3StatusRectPcbRev INTEGER,
+ dm3StatusRectFwVer INTEGER,
+ dm3StatusRectPresent INTEGER,
+ dm3StatusRectDiagPass INTEGER,
+ dm3StatusRectState INTEGER
+ }
+
+dm3StatusRectIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the DC powerplant rectifier."
+ ::= { dm3StatusRectEntry 1 }
+
+dm3StatusRectID OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This OID shows the rectifier ID. This enumerates the number of the rectifier within
+ a group of rectifiers."
+ ::= { dm3StatusRectEntry 2 }
+
+dm3StatusRectDesc OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This OID shows the 16-character rectifier description."
+ ::= { dm3StatusRectEntry 3 }
+
+dm3StatusRectCurrent OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This OID shows the rectifier current in thousandths of Amps (mA)."
+ ::= { dm3StatusRectEntry 4 }
+
+dm3StatusRectCurrentLimit OBJECT-TYPE
+ SYNTAX INTEGER {
+ statusTrue (1),
+ statusFalse (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this OID will return statusTrue (1) if the rectifier is in the Current Limit state.
+ statusFalse (2) will be returned if the rectifier is not in the Current Limit state."
+ ::= { dm3StatusRectEntry 5 }
+
+dm3StatusRectStandby OBJECT-TYPE
+ SYNTAX INTEGER {
+ statusTrue (1),
+ statusFalse (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this OID will return statusTrue (1) if the rectifier is in the Standby state.
+ statusFalse (2) will be returned if the rectifier is not in the Standby state."
+ ::= { dm3StatusRectEntry 6 }
+
+dm3StatusRectFanFail OBJECT-TYPE
+ SYNTAX INTEGER {
+ statusTrue (1),
+ statusFalse (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this OID will return statusTrue (1) if the rectifier Fan has failed.
+ statusFalse (2) will be returned if the rectifier Fan has not failed."
+ ::= { dm3StatusRectEntry 7 }
+
+dm3StatusRectFail OBJECT-TYPE
+ SYNTAX INTEGER {
+ statusTrue (1),
+ statusFalse (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this OID will return statusTrue (1) if the rectifier has failed.
+ statusFalse (2) will be returned if the rectifier has not failed."
+ ::= { dm3StatusRectEntry 8 }
+
+dm3StatusRectDevType OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This OID shows the rectifier device type."
+ ::= { dm3StatusRectEntry 9 }
+
+dm3StatusRectPhyAddr OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This OID shows the rectifier physical address (the address on the bus)."
+ ::= { dm3StatusRectEntry 10 }
+
+dm3StatusRectCfg OBJECT-TYPE
+ SYNTAX INTEGER {
+ statusTrue (1),
+ statusFalse (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this OID will return statusTrue (1) if the rectifier is present after
+ power-up or set-configuration.
+ statusFalse (2) will be returned if the rectifier is not configured."
+ ::= { dm3StatusRectEntry 11 }
+
+dm3StatusRectPcbRev OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This OID shows the rectifier device PCB serial number."
+ ::= { dm3StatusRectEntry 12 }
+
+dm3StatusRectFwVer OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This OID shows the rectifier device firmware revision."
+ ::= { dm3StatusRectEntry 13 }
+
+dm3StatusRectPresent OBJECT-TYPE
+ SYNTAX INTEGER {
+ statusTrue (1),
+ statusFalse (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this OID will return statusTrue (1) if the rectifier is present.
+ statusFalse (2) will be returned if the rectifier is not present."
+ ::= { dm3StatusRectEntry 14 }
+
+dm3StatusRectDiagPass OBJECT-TYPE
+ SYNTAX INTEGER {
+ statusTrue (1),
+ statusFalse (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this OID will return statusTrue (1) if the rectifier diagnostics have passed.
+ statusFalse (2) will be returned if the rectifier diagnostics have not passed."
+ ::= { dm3StatusRectEntry 15 }
+
+dm3StatusRectState OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This OID shows the rectifier device state as defined by the device status register."
+ ::= { dm3StatusRectEntry 16 }
+
+dm3StatusSysRectVoltSanity OBJECT-TYPE
+ SYNTAX INTEGER {
+ saneYES (1),
+ saneNO (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Rectifier voltage sanity indicator. Indicates if the rectifier voltage is
+ reasonable. Reasonable is defined based on powerplant type. A value of saneYes (1)
+ indicates voltage is reasonable, a value of saneNo (2) indicates it is not."
+ ::= { dm3StatusRectifier 3 }
+
+dm3StatusSysRectAvailable OBJECT-TYPE
+ SYNTAX INTEGER {
+ statusTrue (1),
+ statusFalse (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this OID will return statusTrue (1) if the rectifier is available.
+ statusFalse (2) will be returned if the rectifier is not available."
+ ::= { dm3StatusRectifier 4 }
+
+dm3StatusSysRectType OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This OID shows the type of rectifier the system has. There can only be a single type of
+ rectifier in the power plant"
+ ::= { dm3StatusRectifier 5 }
+
+dm3StatusSysRectVoltage OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This OID shows the system level rectifier voltage in thousandths of Volts (mV)."
+ ::= { dm3StatusRectifier 6 }
+
+dm3StatusSysRectCurrent OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This OID shows the system level rectifier current in thousandths of Amps (mA)."
+ ::= { dm3StatusRectifier 7 }
+
+
+-- the dm3StatusConverter group
+
+dm3StatusConvTableSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of DC powerplant converters viewable
+ by this IP address."
+ ::= { dm3StatusConverter 1 }
+
+dm3StatusConvTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF StatusConvEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for viewing status of the converters. The number of
+ entries is contained in the dm3StatusConvTableSize OID."
+ ::= { dm3StatusConverter 2 }
+
+dm3StatusConvEntry OBJECT-TYPE
+ SYNTAX StatusConvEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The converter to gather status from."
+ INDEX { dm3StatusConvIndex }
+ ::= { dm3StatusConvTable 1 }
+
+StatusConvEntry ::=
+ SEQUENCE {
+ dm3StatusConvIndex INTEGER,
+ dm3StatusConvID INTEGER,
+ dm3StatusConvDesc DisplayString,
+ dm3StatusConvCurrent INTEGER,
+ dm3StatusConvCurrentLimit INTEGER,
+ dm3StatusConvStandby INTEGER,
+ dm3StatusConvFanFail INTEGER,
+ dm3StatusConvFail INTEGER,
+ dm3StatusConvDevType INTEGER,
+ dm3StatusConvPhyAddr INTEGER,
+ dm3StatusConvCfg INTEGER,
+ dm3StatusConvPcbRev INTEGER,
+ dm3StatusConvFwVer INTEGER,
+ dm3StatusConvPresent INTEGER,
+ dm3StatusConvDiagPass INTEGER,
+ dm3StatusConvState INTEGER
+ }
+
+dm3StatusConvIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the DC powerplant converter."
+ ::= { dm3StatusConvEntry 1 }
+
+dm3StatusConvID OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This OID shows the converter ID. This enumerates the number of the converter within
+ a group of converters."
+ ::= { dm3StatusConvEntry 2 }
+
+dm3StatusConvDesc OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This OID shows the 16 character converter description."
+ ::= { dm3StatusConvEntry 3 }
+
+dm3StatusConvCurrent OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This OID shows the converter current in thousandths of Amps (mA)."
+ ::= { dm3StatusConvEntry 4 }
+
+dm3StatusConvCurrentLimit OBJECT-TYPE
+ SYNTAX INTEGER {
+ statusTrue (1),
+ statusFalse (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this OID will return statusTrue (1) if the converter is in the Current Limit state.
+ statusFalse (2) will be returned if the converter is not in the Current Limit state."
+ ::= { dm3StatusConvEntry 5 }
+
+dm3StatusConvStandby OBJECT-TYPE
+ SYNTAX INTEGER {
+ statusTrue (1),
+ statusFalse (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this OID will return statusTrue (1) if the converter is in the Standby state.
+ statusFalse (2) will be returned if the converter is not in the Standby state."
+ ::= { dm3StatusConvEntry 6 }
+
+dm3StatusConvFanFail OBJECT-TYPE
+ SYNTAX INTEGER {
+ statusTrue (1),
+ statusFalse (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this OID will return statusTrue (1) if the converter Fan has failed.
+ statusFalse (2) will be returned if the converter Fan has not failed."
+ ::= { dm3StatusConvEntry 7 }
+
+dm3StatusConvFail OBJECT-TYPE
+ SYNTAX INTEGER {
+ statusTrue (1),
+ statusFalse (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this OID will return statusTrue (1) if the converter has failed.
+ statusFalse (2) will be returned if the converter has not failed."
+ ::= { dm3StatusConvEntry 8 }
+
+dm3StatusConvDevType OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This OID shows the converter device type."
+ ::= { dm3StatusConvEntry 9 }
+
+dm3StatusConvPhyAddr OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This OID shows the converter physical address (the address on the bus)."
+ ::= { dm3StatusConvEntry 10 }
+
+dm3StatusConvCfg OBJECT-TYPE
+ SYNTAX INTEGER {
+ statusTrue (1),
+ statusFalse (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this OID will return statusTrue (1) if the converter is present after
+ power-up or set-configuration.
+ statusFalse (2) will be returned if the converter is not configured."
+ ::= { dm3StatusConvEntry 11 }
+
+dm3StatusConvPcbRev OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This OID shows the converter device PCB serial number."
+ ::= { dm3StatusConvEntry 12 }
+
+dm3StatusConvFwVer OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This OID shows the converter device firmware version."
+ ::= { dm3StatusConvEntry 13 }
+
+dm3StatusConvPresent OBJECT-TYPE
+ SYNTAX INTEGER {
+ statusTrue (1),
+ statusFalse (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this OID will return statusTrue (1) if the converter is present.
+ statusFalse (2) will be returned if the converter is not present."
+ ::= { dm3StatusConvEntry 14 }
+
+dm3StatusConvDiagPass OBJECT-TYPE
+ SYNTAX INTEGER {
+ statusTrue (1),
+ statusFalse (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this OID will return statusTrue (1) if the converter diagnostics have passed.
+ statusFalse (2) will be returned if the converter diagnostics have not passed."
+ ::= { dm3StatusConvEntry 15 }
+
+dm3StatusConvState OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This OID shows the converter state as defined by the device status register."
+ ::= { dm3StatusConvEntry 16 }
+
+dm3StatusSysConvVoltSanity OBJECT-TYPE
+ SYNTAX INTEGER{
+ saneYES (1),
+ saneNO (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Converter voltage sanity indicator. Indicates if the converter voltage is
+ reasonable. Reasonable is defined based on powerplant type. A value of saneYes (1)
+ indicates voltage is reasonable, a value of saneNo (2) indicates it is not."
+ ::= { dm3StatusConverter 3 }
+
+dm3StatusSysConvAvailable OBJECT-TYPE
+ SYNTAX INTEGER {
+ statusTrue (1),
+ statusFalse (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this OID will return statusTrue (1) if the converter is available.
+ statusFalse (2) will be returned if the converter is not available."
+ ::= { dm3StatusConverter 4 }
+
+dm3StatusSysConvType OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This OID shows the converter type."
+ ::= { dm3StatusConverter 5 }
+
+dm3StatusSysConvVoltage OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This OID shows the system level converter voltage in thousandths of volts (mV)."
+ ::= { dm3StatusConverter 6 }
+
+dm3StatusSysConvCurrent OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This OID shows the system level converter current in thousandths of Amps (mA)."
+ ::= { dm3StatusConverter 7 }
+
+-- the dm3StatusOutputRelays group
+
+dm3StatusOutRlyTableSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of DC powerplant output relays viewable
+ by this IP address."
+ ::= { dm3StatusOutputRelays 1 }
+
+dm3StatusOutRlyTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF StatusOutRlyEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for viewing status of the output relays. The number of
+ entries is contained in the dm3StatusOutRlyTableSize OID."
+ ::= { dm3StatusOutputRelays 2 }
+
+dm3StatusOutRlyEntry OBJECT-TYPE
+ SYNTAX StatusOutRlyEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The output relay to gather status from."
+ INDEX { dm3StatusOutRlyIndex }
+ ::= { dm3StatusOutRlyTable 1 }
+
+StatusOutRlyEntry ::=
+ SEQUENCE {
+ dm3StatusOutRlyIndex INTEGER,
+ dm3StatusOutRlyName DisplayString,
+ dm3StatusOutRlyStatus INTEGER
+ }
+
+dm3StatusOutRlyIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the DC powerplant output relay."
+ ::= { dm3StatusOutRlyEntry 1 }
+
+dm3StatusOutRlyName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The name of the output relay. The maximum size is
+ 16 characters. The name is set by using the
+ dm3ConfigOutRlyName OID.
+ This OID is provided for informational purposes only."
+ ::= { dm3StatusOutRlyEntry 2 }
+
+dm3StatusOutRlyStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ statusOn (1),
+ statusOff (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this OID will return statusOn (1) if the output relay is enabled/on.
+ statusOff (2) will be returned if the output relay is disabled/off."
+ ::= { dm3StatusOutRlyEntry 3 }
+
+
+-- the dm3StatusInputRelays group
+
+dm3StatusInRlyTableSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of DC powerplant input relays viewable
+ by this IP address."
+ ::= { dm3StatusInputRelays 1 }
+
+dm3StatusInRlyTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF StatusInRlyEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for viewing status of the input relays. The number of
+ entries is contained in the dm3StatusInRlyTableSize OID."
+ ::= { dm3StatusInputRelays 2 }
+
+
+dm3StatusInRlyEntry OBJECT-TYPE
+ SYNTAX StatusInRlyEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The input relays to gather status from."
+ INDEX { dm3StatusInRlyIndex }
+ ::= { dm3StatusInRlyTable 1 }
+
+StatusInRlyEntry ::=
+ SEQUENCE {
+ dm3StatusInRlyIndex INTEGER,
+ dm3StatusInRlyName DisplayString,
+ dm3StatusInRlyStatus INTEGER
+ }
+
+dm3StatusInRlyIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the DC powerplant input relay."
+ ::= { dm3StatusInRlyEntry 1 }
+
+dm3StatusInRlyName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The name of the input relay. The maximum size is
+ 16 characters. The name is set by using the
+ dm3ConfigInRlyName OID.
+ This OID is provided for informational purposes only."
+ ::= { dm3StatusInRlyEntry 2 }
+
+dm3StatusInRlyStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ statusOn (1),
+ statusOff (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this OID will return statusOn (1) if the input relay is enabled/on.
+ statusOff (2) will be returned if the input relay is disabled/off."
+ ::= { dm3StatusInRlyEntry 3 }
+
+-- the dm3StatusBreakers group
+
+dm3StatusBreakersTableSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of DC powerplant circuit breakers viewable
+ by this IP address."
+ ::= { dm3StatusBreakers 1 }
+
+dm3StatusBreakersTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF StatusBreakersEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for viewing status of the circuit breakers. The number of
+ entries is contained in the dm3StatusBreakersTableSize OID."
+ ::= { dm3StatusBreakers 2 }
+
+dm3StatusBreakersEntry OBJECT-TYPE
+ SYNTAX StatusBreakersEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The circuit breaker to gather status from."
+ INDEX { dm3StatusBreakersIndex }
+ ::= { dm3StatusBreakersTable 1 }
+
+StatusBreakersEntry ::=
+ SEQUENCE {
+ dm3StatusBreakersIndex INTEGER,
+ dm3StatusBreakersName DisplayString,
+ dm3StatusBreakersStatus INTEGER
+ }
+
+dm3StatusBreakersIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the DC powerplant circuit breaker."
+ ::= { dm3StatusBreakersEntry 1 }
+
+dm3StatusBreakersName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The name of the circuit breaker. The maximum size is
+ 16 characters. The name is set by using the
+ dm3ConfigBreakersName OID.
+ This OID is provided for informational purposes only."
+ ::= { dm3StatusBreakersEntry 2 }
+
+dm3StatusBreakersStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ statusClosed (1),
+ statusOpen (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this OID will return statusClosed (1) if the circuit breaker is closed.
+ statusOpen (2) will be returned if the circuit breaker is open."
+ ::= { dm3StatusBreakersEntry 3 }
+
+-- the dm3StatusFuses group
+
+dm3StatusFusesTableSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of DC powerplant fuses controllable
+ by this IP address."
+ ::= { dm3StatusFuses 1 }
+
+dm3StatusFusesTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF StatusFusesEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for viewing status of the fuses. The number of
+ entries is contained in the dm3StatusFusesTableSize OID."
+ ::= { dm3StatusFuses 2 }
+
+dm3StatusFusesEntry OBJECT-TYPE
+ SYNTAX StatusFusesEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The fuse to gather status from."
+ INDEX { dm3StatusFusesIndex }
+ ::= { dm3StatusFusesTable 1 }
+
+StatusFusesEntry ::=
+ SEQUENCE {
+ dm3StatusFusesIndex INTEGER,
+ dm3StatusFusesName DisplayString,
+ dm3StatusFusesStatus INTEGER
+ }
+
+dm3StatusFusesIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the DC powerplant fuse."
+ ::= { dm3StatusFusesEntry 1 }
+
+dm3StatusFusesName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The name of the fuse. The maximum size is
+ 16 characters. The name is set by using the
+ dm3ConfigFuseName OID.
+ This OID is provided for informational purposes only."
+ ::= { dm3StatusFusesEntry 2 }
+
+dm3StatusFusesStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ statusClosed (1),
+ statusOpen (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this OID will return statusClosed (1) if the fuse is closed.
+ statusOpen (2) will be returned if the fuse is open."
+ ::= { dm3StatusFusesEntry 3 }
+
+-- the atsIdent group
+
+atsIdentHardwareRev OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The hardware version of the Automatic Transfer Switch.
+ This value is set at the factory."
+ ::= { atsIdent 1 }
+
+atsIdentFirmwareRev OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A string identifying the Automatic Transfer Switch
+ firmware version."
+ ::= { atsIdent 2 }
+
+atsIdentFirmwareDate OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The date of release for this Automatic Transfer Switch
+ firmware version. "
+ ::= { atsIdent 3 }
+
+atsIdentDateOfManufacture OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The date when the Automatic Transfer Switch was manufactured in mm/dd/yyyy format.
+ This value is set at the factory. "
+ ::= { atsIdent 4 }
+
+atsIdentModelNumber OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A string identifying the model number of the Automatic Transfer Switch.
+ This value is set at the factory."
+ ::= { atsIdent 5 }
+
+atsIdentSerialNumber OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A string identifying the serial number of
+ the Automatic Transfer Switch. This value is set at the factory."
+ ::= { atsIdent 6 }
+
+atsIdentNominalLineVoltage OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "RMS Utility Voltage measured in V."
+ ::= { atsIdent 7 }
+
+atsIdentNominalLineFrequency OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Utility Power Frequency measured in Hz."
+ ::= { atsIdent 8 }
+
+-- the atsCalibration group
+
+-- Input Voltage Calibration Factor table
+
+ atsCalibrationNumInputs OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of inputs to this device."
+ ::= { atsCalibrationInput 1 }
+
+ atsCalibrationNumInputPhases OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of phases per input for this device."
+ ::= { atsCalibrationInput 2 }
+
+ atsCalibrationInputTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ATSCalibrationInputPhaseEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The number of phases per input line to this device."
+ ::= { atsCalibrationInput 3 }
+
+ atsCalibrationInputPhaseEntry OBJECT-TYPE
+ SYNTAX ATSCalibrationInputPhaseEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "An entry containing calibration information applicable to a
+ particular input phase."
+ INDEX { atsCalibrationInputTableIndex, atsCalibrationInputPhaseTableIndex }
+ ::= { atsCalibrationInputTable 1 }
+
+ ATSCalibrationInputPhaseEntry ::= SEQUENCE {
+ atsCalibrationInputTableIndex INTEGER,
+ atsCalibrationInputPhaseTableIndex INTEGER,
+ atsLineVoltageCalibrationFactor INTEGER
+ }
+
+ atsCalibrationInputTableIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The input identifier."
+ ::= { atsCalibrationInputPhaseEntry 1 }
+
+ atsCalibrationInputPhaseTableIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The input phase identifier."
+ ::= { atsCalibrationInputPhaseEntry 2 }
+
+ atsLineVoltageCalibrationFactor OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The Line Voltage Calibration factor.
+ This value is set at the factory."
+ ::= { atsCalibrationInputPhaseEntry 3 }
+
+-- Power Supply Voltage Calibration table
+
+ atsCalibrationPowerSupplyVoltages OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of power supply voltages supported by this device.
+ This variable indicates the number of rows in the
+ atsCalibrationPowerSupplyTable. There is one entry per
+ supported voltage: 24V, 12V and 5V"
+ ::= { atsCalibrationPowerSupply 1 }
+
+ atsCalibrationPowerSupplyVoltageTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ATSCalibrationPowerSupplyVoltageEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A list of Power Supply table entries."
+ ::= { atsCalibrationPowerSupply 2 }
+
+ atsCalibrationPowerSupplyVoltageEntry OBJECT-TYPE
+ SYNTAX ATSCalibrationPowerSupplyVoltageEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "An entry containing information applicable to a
+ particular Power Supply Voltage."
+ INDEX { atsCalibrationPowerSupplyVoltageTableIndex }
+ ::= { atsCalibrationPowerSupplyVoltageTable 1 }
+
+ ATSCalibrationPowerSupplyVoltageEntry ::= SEQUENCE {
+ atsCalibrationPowerSupplyVoltageTableIndex INTEGER,
+ atsCalibrationPowerSupplyVoltage INTEGER,
+ atsPowerSupplyVoltageCalibrationFactor INTEGER
+ }
+
+ atsCalibrationPowerSupplyVoltageTableIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The power supply voltage identifier.
+ Three power supply voltages are supported by the ATS:
+ 24V , 12V and 5V .
+ The value of this index indicates the power supply voltage:
+ 1 = 24V
+ 2 = 12V
+ 3 = 5V"
+ ::= { atsCalibrationPowerSupplyVoltageEntry 1 }
+
+ atsCalibrationPowerSupplyVoltage OBJECT-TYPE
+ SYNTAX INTEGER {
+ powerSupply24V(1),
+ powerSupply12V(2),
+ powerSupply(3)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This value describes the power supply voltage."
+ ::= { atsCalibrationPowerSupplyVoltageEntry 2 }
+
+ atsPowerSupplyVoltageCalibrationFactor OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The Line Voltage Calibration factor.
+ This value is set at the factory."
+ ::= { atsCalibrationPowerSupplyVoltageEntry 3 }
+
+-- Output Current Calibration table
+
+ atsCalibrationNumOutputs OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of output lines from this device.
+ This variable indicates the number of rows in the
+ atsCalibrationOutputTable."
+ ::= { atsCalibrationOutput 1 }
+
+ atsCalibrationNumOutputPhases OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of output phases utilized in this
+ device."
+ ::= { atsCalibrationOutput 2 }
+
+ atsCalibrationOutputTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ATSCalibrationOutputEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A list of output table entries."
+ ::= { atsCalibrationOutput 3 }
+
+ atsCalibrationOutputEntry OBJECT-TYPE
+ SYNTAX ATSCalibrationOutputEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "An entry containing information applicable to a
+ particular output."
+ INDEX { atsCalibrationOutputTableIndex, atsCalibrationOutputPhasesTableIndex }
+ ::= { atsCalibrationOutputTable 1 }
+
+ ATSCalibrationOutputEntry ::= SEQUENCE {
+ atsCalibrationOutputTableIndex INTEGER,
+ atsCalibrationOutputPhasesTableIndex INTEGER,
+ atsOutputCurrentCalibrationFactor INTEGER
+ }
+
+ atsCalibrationOutputTableIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The output identifier."
+ ::= { atsCalibrationOutputEntry 1 }
+
+ atsCalibrationOutputPhasesTableIndex OBJECT-TYPE
+ SYNTAX INTEGER{
+ phase1(1),
+ phase2(2),
+ phase3(3),
+ neutral(4)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Description of each calibration factor for each
+ output phase utilized in this device and one for neutral. "
+ ::= { atsCalibrationOutputEntry 2 }
+
+ atsOutputCurrentCalibrationFactor OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The output current calibration factor measured in Amps."
+ ::= { atsCalibrationOutputEntry 3 }
+
+
+-- the atsControl group
+
+atsControlResetATS OBJECT-TYPE
+ SYNTAX INTEGER {
+ none(1),
+ reset(2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Setting this variable will cause the Automatic Transfer Switch to
+ perform a power-on reset."
+ ::= { atsControl 1 }
+
+atsControlClearAllAlarms OBJECT-TYPE
+ SYNTAX INTEGER {
+ none(1),
+ clear(2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Setting this variable will clear all alarms in the Automatic Transfer Switch."
+ ::= { atsControl 2 }
+
+-- the atsConfig group
+
+atsConfigProductName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "A configurable character string."
+ ::= { atsConfig 1 }
+
+atsConfigPreferredSource OBJECT-TYPE
+ SYNTAX INTEGER {
+ sourceA(1),
+ sourceB(2),
+ none(3)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "This variable returns the preferred source of power when both sources are OK."
+ ::= { atsConfig 2 }
+
+atsConfigFrontPanelLockout OBJECT-TYPE
+ SYNTAX INTEGER {
+ disableFrontPanel(1),
+ enableFrontPanel(2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Setting this variable to disableFrontPanel(1) will disallow source
+ preference configuration of the Automatic Transfer Switch via the
+ Front Panel. Once this value is set, it can only be re-enabled through
+ the serial interface of the ATS.
+ When this variable is set to enableFrontPanel(2), source preference
+ configuration of the Automatic Transfer Switch via the Front Panel
+ is allowed."
+ ::= { atsConfig 3 }
+
+atsConfigVoltageSensitivity OBJECT-TYPE
+ SYNTAX INTEGER {
+ high(1),
+ low(2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "This variable defines the sensitivity to changes in voltage:
+ high(1) for best protection, low(2) for frequent small line
+ voltage changes."
+ ::= { atsConfig 4 }
+
+atsConfigTransferVoltageRange OBJECT-TYPE
+ SYNTAX INTEGER {
+ wide(1),
+ medium(2),
+ narrow(3)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "This variable defines the range of acceptable voltage from a power source.
+ If the voltage measured from the selected input source is not within this
+ range, the Automatic Transfer Switch will switch over (transfer) to the
+ alternate power source."
+
+ ::= { atsConfig 5 }
+
+atsConfigCurrentLimit OBJECT-TYPE
+ SYNTAX INTEGER (0..20)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The threshold (in Amps) at which an Over Current Alarm will be generated."
+
+ ::= { atsConfig 6 }
+
+
+atsConfigResetValues OBJECT-TYPE
+ SYNTAX INTEGER {
+ none(1),
+ reset(2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Resets the ATS configuration to its default values."
+
+ ::= { atsConfig 7 }
+
+-- the atsStatus group
+
+ atsStatusCommStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ atsNeverDiscovered(1),
+ atsCommEstablished(2),
+ atsCommLost(3)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This variable returns the current communication status
+ of the Automatic Transfer Switch. "
+ ::= { atsStatusDeviceStatus 1 }
+
+ atsStatusSelectedSource OBJECT-TYPE
+ SYNTAX INTEGER {
+ sourceA(1),
+ sourceB(2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This variable returns the current source of power. "
+ ::= { atsStatusDeviceStatus 2 }
+
+ atsStatusRedundancyState OBJECT-TYPE
+ SYNTAX INTEGER {
+ atsRedundancyLost(1),
+ atsFullyRedundant(2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This variable returns the current redundancy state of the ATS.
+ atsRedundancyLost(1) indicates that the ATS is unable to
+ switch over to the alternate power source if the current source fails.
+ atsFullyRedundant(2) indicates that the ATS will switch over to
+ the alternate power source if the current source fails."
+ ::= { atsStatusDeviceStatus 3 }
+
+ atsStatusOverCurrentState OBJECT-TYPE
+ SYNTAX INTEGER {
+ atsOverCurrent(1),
+ atsCurrentOK(2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This variable returns the output current state of the ATS.
+ atsOverCurrent(1) indicates that the ATS has exceeded the output
+ current threshold and will not allow a switch over to the alternate power
+ source if the current source fails.
+ atsCurrentOK(2) indicates that the output current is below the
+ output current threshold."
+ ::= { atsStatusDeviceStatus 4 }
+
+ atsStatus5VPowerSupply OBJECT-TYPE
+ SYNTAX INTEGER {
+ atsPowerSupplyFailure(1),
+ atsPowerSupplyOK(2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This variable returns the current state of the ATS 5-volt power supply.
+ atsPowerSupplyFailure(1) indicates the 5-volt power supply has failed
+ and that the ATS serial port Configuration Menu is not accessible .
+ atsPowerSupplyOK(2) indicates that the ATS 5-volt power supply
+ is operating within tolerance."
+ ::= { atsStatusDeviceStatus 5 }
+
+ atsStatus24VPowerSupply OBJECT-TYPE
+ SYNTAX INTEGER {
+ atsPowerSupplyFailure(1),
+ atsPowerSupplyOK(2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This variable returns the current state of the ATS 24-volt power supply.
+ atsPowerSupplyFailure(1) indicates the 24-volt power supply has failed
+ and the ATS is unable to switch over to the alternate power source if
+ the current source fails.
+ atsPowerSupplyOK(2) indicates that the ATS 24-volt power supply
+ is operating within tolerance."
+ ::= { atsStatusDeviceStatus 6 }
+
+ atsStatusResetMaxMinValues OBJECT-TYPE
+ SYNTAX INTEGER {
+ none(1),
+ reset(2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Resets the maximum and minimum ATS values:
+ atsInputMaxVoltage, atsInputMinVoltage,
+ atsInputMaxCurrent, atsInputMinCurrent,
+ atsInputMaxPower, atsInputMinPower,
+ atsOutputMaxCurrent, atsOutputMinCurrent,
+ atsOutputMaxLoad, atsOutputMinLoad,
+ atsOutputMaxPercentLoad, atsOutputMinPercentLoad,
+ atsOutputMaxPower, atsOutputMinPower,
+ atsOutputMaxPercentPower, atsOutputMinPercentPower.
+ These variables represent the maximum and minimum ATS values
+ since the last time they were read or reset by this OID.
+ Values unsupported by this ATS will return (-1)."
+ ::= { atsStatusResetValues 1 }
+
+--
+-- Input Group
+--
+
+-- Number of Inputs
+
+ atsNumInputs OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of input feeds to this device.
+ This variable indicates the number of rows in the
+ input table."
+ ::= { atsStatusInput 1 }
+
+-- Input Table
+
+ atsInputTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ATSPhaseInputEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A list of input table entries. The number of entries
+ is given by the value of atsNumInputs."
+ ::= { atsStatusInput 2 }
+
+ atsInputEntry OBJECT-TYPE
+ SYNTAX ATSPhaseInputEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "An entry containing information applicable to a
+ particular input."
+ INDEX { atsInputTableIndex }
+ ::= { atsInputTable 1 }
+
+ ATSPhaseInputEntry ::= SEQUENCE {
+ atsInputTableIndex INTEGER,
+ atsNumInputPhases INTEGER,
+ atsInputVoltageOrientation INTEGER,
+ atsInputFrequency INTEGER,
+ atsInputType INTEGER,
+ atsInputName DisplayString
+ }
+
+ atsInputTableIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The input identifier."
+ ::= { atsInputEntry 1 }
+
+ atsNumInputPhases OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of input phases utilized in this
+ device. The sum of all the atsNumInputPhases
+ variable indicates the number of rows in the
+ input phase table."
+ ::= { atsInputEntry 2 }
+
+ atsInputVoltageOrientation OBJECT-TYPE
+ SYNTAX INTEGER {
+ unknown(1),
+ singlePhase(2),
+ splitPhase(3),
+ threePhasePhaseToNeutral(4),
+ threePhasePhaseToPhase(5)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The input voltage orientation:
+ 1: unknown for this Source
+ 2: singlePhase - phase 1 voltage is between Phase 1
+ and Neutral.
+ 3: splitPhase - phase 1 voltage is between Phase 1 and
+ Neutral; phase 2 voltage is between Phase 2 and Neutral;
+ phase 3 voltage is between Phase 1 and Phase2.
+ 4: threePhasePhaseToNeutral - phase 1 voltage is between
+ Phase 1 and Neutral; phase 2 voltage is between Phase 2
+ and Neutral; phase 3 voltage is between Phase3 and
+ Neutral.
+ 5: threePhasePhaseToPhase - phase 1 voltage is between
+ Phase 1 and Phase 2; phase 2 voltage is between Phase 2
+ and Phase 3; phase 3 voltage is between Phase 3 and
+ Phase 1."
+ ::= { atsInputEntry 3 }
+
+ atsInputFrequency OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The input frequency in Hertz, or -1 if it's unsupported
+ by this Source."
+ ::= { atsInputEntry 4 }
+
+ atsInputType OBJECT-TYPE
+ SYNTAX INTEGER {
+ unknown(1),
+ main(2),
+ bypass(3)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The input type."
+ ::= { atsInputEntry 5 }
+
+ atsInputName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "A name given to a particular input."
+ ::= { atsInputEntry 6 }
+
+-- Input Phase Table
+
+ atsInputPhaseTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ATSPhaseInputPhaseEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A list of input table entries. The number of entries
+ is given by the sum of the atsNumInputPhases."
+ ::= { atsStatusInput 3 }
+
+ atsInputPhaseEntry OBJECT-TYPE
+ SYNTAX ATSPhaseInputPhaseEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "An entry containing information applicable to a
+ particular input phase."
+ INDEX { atsInputPhaseTableIndex, atsInputPhaseIndex }
+ ::= { atsInputPhaseTable 1 }
+
+ ATSPhaseInputPhaseEntry ::= SEQUENCE {
+ atsInputPhaseTableIndex INTEGER,
+ atsInputPhaseIndex INTEGER,
+ atsInputVoltage INTEGER,
+ atsInputMaxVoltage INTEGER,
+ atsInputMinVoltage INTEGER,
+ atsInputCurrent INTEGER,
+ atsInputMaxCurrent INTEGER,
+ atsInputMinCurrent INTEGER,
+ atsInputPower INTEGER,
+ atsInputMaxPower INTEGER,
+ atsInputMinPower INTEGER
+ }
+
+ atsInputPhaseTableIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The input identifier."
+ ::= { atsInputPhaseEntry 1 }
+
+ atsInputPhaseIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The input phase identifier."
+ ::= { atsInputPhaseEntry 2 }
+
+ atsInputVoltage OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The input voltage in VAC, or -1 if it's unsupported
+ by this Source."
+ ::= { atsInputPhaseEntry 3 }
+
+ atsInputMaxVoltage OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The maximum input voltage in VAC measured
+ since the last time this variable was read
+ or reset (atsStatusResetMaxMinValues).
+ Returns (-1) if unsupported."
+ ::= { atsInputPhaseEntry 4 }
+
+ atsInputMinVoltage OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The minimum input voltage in VAC measured
+ since the last time this variable was read
+ or reset (atsStatusResetMaxMinValues).
+ Returns (-1) if unsupported."
+ ::= { atsInputPhaseEntry 5 }
+
+ atsInputCurrent OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The input current in amperes, or -1 if it's
+ unsupported by this Source."
+ ::= { atsInputPhaseEntry 6 }
+
+ atsInputMaxCurrent OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The maximum input current in amperes measured
+ since the last time this variable was read
+ or reset (atsStatusResetMaxMinValues).
+ Returns (-1) if unsupported."
+ ::= { atsInputPhaseEntry 7 }
+
+ atsInputMinCurrent OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The minimum input current in amperes measured
+ since the last time this variable was read
+ or reset (atsStatusResetMaxMinValues).
+ Returns (-1) if unsupported."
+ ::= { atsInputPhaseEntry 8 }
+
+ atsInputPower OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The input power in Watts, or -1 if it's unsupported
+ by this Source."
+ ::= { atsInputPhaseEntry 9 }
+
+ atsInputMaxPower OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The maximum input power in Watts measured
+ since the last time this variable was read
+ or reset (atsStatusResetMaxMinValues).
+ Returns (-1) if unsupported."
+ ::= { atsInputPhaseEntry 10 }
+
+ atsInputMinPower OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The minimum input power in Watts measured
+ since the last time this variable was read
+ or reset (atsStatusResetMaxMinValues).
+ Returns (-1) if unsupported."
+ ::= { atsInputPhaseEntry 11 }
+
+ --
+ -- The Output group.
+ --
+
+ -- Number of Outputs
+
+ atsNumOutputs OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of output feeds to this device.
+ This variable indicates the number of rows in the
+ output table."
+ ::= { atsStatusOutput 1 }
+
+ -- Output Table
+
+ atsOutputTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ATSPhaseOutputEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A list of output table entries. The number of entries
+ is given by the value of atsOutputNumPhases."
+ ::= { atsStatusOutput 2 }
+
+ atsOutputEntry OBJECT-TYPE
+ SYNTAX ATSPhaseOutputEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "An entry containing information applicable to a
+ particular output."
+ INDEX { atsOutputTableIndex }
+ ::= { atsOutputTable 1 }
+
+ ATSPhaseOutputEntry ::= SEQUENCE {
+ atsOutputTableIndex INTEGER,
+ atsNumOutputPhases INTEGER,
+ atsOutputVoltageOrientation INTEGER,
+ atsOutputFrequency INTEGER
+ }
+
+ atsOutputTableIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The output identifier."
+ ::= { atsOutputEntry 1 }
+
+ atsNumOutputPhases OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of output phases utilized in this
+ device. The sum of all the atsNumOutputPhases
+ variable indicates the number of rows in the
+ output phase table."
+ ::= { atsOutputEntry 2 }
+
+ atsOutputVoltageOrientation OBJECT-TYPE
+ SYNTAX INTEGER {
+ unknown(1),
+ singlePhase(2),
+ splitPhase(3),
+ threePhasePhaseToNeutral(4),
+ threePhasePhaseToPhase(5)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The output voltage orientation:
+ 1: unknown for this ATS
+ 2: singlePhase - phase 1 voltage is between Phase 1
+ and Neutral.
+ 3: splitPhase - phase 1 voltage is between Phase 1 and
+ Neutral; phase 2 voltage is between Phase 2 and Neutral;
+ phase 3 voltage is between Phase 1 and Phase2.
+ 4: threePhasePhaseToNeutral - phase 1 voltage is between
+ Phase 1 and Neutral; phase 2 voltage is between Phase 2
+ and Neutral; phase 3 voltage is between Phase3 and
+ Neutral.
+ 5: threePhasePhaseToPhase - phase 1 voltage is between
+ Phase 1 and Phase 2; phase 2 voltage is between Phase 2
+ and Phase 3; phase 3 voltage is between Phase 3 and
+ Phase 1."
+ ::= { atsOutputEntry 3 }
+
+ atsOutputFrequency OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The output frequency in Hertz, or -1 if it's
+ unsupported by this ATS."
+ ::= { atsOutputEntry 4 }
+
+ -- Output Phase Table
+
+ atsOutputPhaseTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ATSPhaseOutputPhaseEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A list of output table entries. The number of
+ entries is given by the sum of the atsNumOutputPhases."
+ ::= { atsStatusOutput 3 }
+
+ atsOutputPhaseEntry OBJECT-TYPE
+ SYNTAX ATSPhaseOutputPhaseEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "An entry containing information applicable to a
+ particular output phase."
+ INDEX { atsOutputPhaseTableIndex, atsOutputPhaseIndex }
+ ::= { atsOutputPhaseTable 1 }
+
+ ATSPhaseOutputPhaseEntry ::= SEQUENCE {
+ atsOutputPhaseTableIndex INTEGER,
+ atsOutputPhaseIndex INTEGER,
+ atsOutputVoltage INTEGER,
+ atsOutputCurrent INTEGER,
+ atsOutputMaxCurrent INTEGER,
+ atsOutputMinCurrent INTEGER,
+ atsOutputLoad INTEGER,
+ atsOutputMaxLoad INTEGER,
+ atsOutputMinLoad INTEGER,
+ atsOutputPercentLoad INTEGER,
+ atsOutputMaxPercentLoad INTEGER,
+ atsOutputMinPercentLoad INTEGER,
+ atsOutputPower INTEGER,
+ atsOutputMaxPower INTEGER,
+ atsOutputMinPower INTEGER,
+ atsOutputPercentPower INTEGER,
+ atsOutputMaxPercentPower INTEGER,
+ atsOutputMinPercentPower INTEGER
+ }
+
+ atsOutputPhaseTableIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The output identifier."
+ ::= { atsOutputPhaseEntry 1 }
+
+ atsOutputPhaseIndex OBJECT-TYPE
+ SYNTAX INTEGER{
+ phase1(1),
+ phase2(2),
+ phase3(3),
+ neutral(4)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Description of each output phase utilized in
+ this device and one for neutral. "
+ ::= { atsOutputPhaseEntry 2 }
+
+ atsOutputVoltage OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The output voltage in VAC, or -1 if it's unsupported
+ by this ATS."
+ ::= { atsOutputPhaseEntry 3 }
+
+ atsOutputCurrent OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The output current in 0.1 amperes drawn
+ by the load on the ATS, or -1 if it's unsupported
+ by this ATS."
+ ::= { atsOutputPhaseEntry 4 }
+
+ atsOutputMaxCurrent OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The maximum output current in 0.1 amperes measured
+ since the last time this variable was read
+ or reset (atsStatusResetMaxMinValues).
+ Returns (-1) if unsupported."
+ ::= { atsOutputPhaseEntry 5 }
+
+ atsOutputMinCurrent OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The minimum output current in 0.1 amperes measured
+ since the last time this variable was read
+ or reset (atsStatusResetMaxMinValues).
+ Returns (-1) if unsupported."
+ ::= { atsOutputPhaseEntry 6 }
+
+ atsOutputLoad OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The output load in VA, or -1 if it's unsupported
+ by this ATS."
+ ::= { atsOutputPhaseEntry 7 }
+
+ atsOutputMaxLoad OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The maximum output load in VA measured
+ since the last time this variable was read
+ or reset (atsStatusResetMaxMinValues).
+ Returns (-1) if unsupported."
+ ::= { atsOutputPhaseEntry 8 }
+
+ atsOutputMinLoad OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The minimum output load in VA measured
+ since the last time this variable was read
+ or reset (atsStatusResetMaxMinValues).
+ Returns (-1) if unsupported."
+ ::= { atsOutputPhaseEntry 9 }
+
+ atsOutputPercentLoad OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The percentage of the ATS load capacity in VA at
+ redundancy @ (n + x) presently being used on this
+ output phase, or -1 if it's unsupported by this ATS."
+ ::= { atsOutputPhaseEntry 10 }
+
+ atsOutputMaxPercentLoad OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The maximum percentage of the ATS load capacity in
+ VA measured at redundancy @ (n + x) presently
+ being used on this output phase since the last time
+ this variable was read or reset (atsStatusResetMaxMinValues).
+ Returns (-1) if unsupported."
+ ::= { atsOutputPhaseEntry 11 }
+
+ atsOutputMinPercentLoad OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The minimum percentage of the ATS load capacity in
+ VA measured at redundancy @ (n + x) presently
+ being used on this output phase since the last time
+ this variable was read or reset (atsStatusResetMaxMinValues).
+ Returns (-1) if unsupported."
+ ::= { atsOutputPhaseEntry 12 }
+
+ atsOutputPower OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The output power in Watts, or -1 if it's
+ unsupported by this ATS."
+ ::= { atsOutputPhaseEntry 13 }
+
+ atsOutputMaxPower OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The maximum output power in Watts measured
+ since the last time this variable was read
+ or reset (atsStatusResetMaxMinValues).
+ Returns (-1) if unsupported."
+ ::= { atsOutputPhaseEntry 14 }
+
+ atsOutputMinPower OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The minimum output power in Watts measured
+ since the last time this variable was read
+ or reset (atsStatusResetMaxMinValues).
+ Returns (-1) if unsupported."
+ ::= { atsOutputPhaseEntry 15 }
+
+ atsOutputPercentPower OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The percentage of the ATSpower capacity in Watts at
+ redundancy @ (n + x) presently being used on this
+ output phase, or -1 if it's unsupported by this ATS."
+ ::= { atsOutputPhaseEntry 16 }
+
+ atsOutputMaxPercentPower OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The maximum percentage of the ATSpower capacity
+ in Watts measured at redundancy @ (n + x) presently
+ being used on this output phase since the last time
+ this variable was read or reset (atsStatusResetMaxMinValues).
+ Returns (-1) if unsupported."
+ ::= { atsOutputPhaseEntry 17 }
+
+ atsOutputMinPercentPower OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The minimum percentage of the ATSpower capacity
+ in Watts measured at redundancy @ (n + x) presently
+ being used on this output phase since the last time
+ this variable was read or reset (atsStatusResetMaxMinValues).
+ Returns (-1) if unsupported."
+ ::= { atsOutputPhaseEntry 18 }
+
+-- the dcmim2IdentSystem group
+
+dcmim2IdentSysFWVersion OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Integer representation of the power plant Master Controller firmware revision."
+ ::= { dcmim2IdentSystem 1 }
+
+
+-- the dcmim2ControlSystem group
+
+dcmim2ControlRunFunctBatteryTest OBJECT-TYPE
+ SYNTAX INTEGER {
+ battTestOff (1),
+ battTestOn (2)
+}
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this OID will return the battery functional test state. If
+ the test is off, the battTestOff (1) value will be returned.
+ If the test is on, the battTestOn (2) value will be
+ returned.
+
+ Setting this OID to battTestOff (1) will turn the battery functional test off.
+ Setting this OID to battTestOn (2) will turn the battery functional test on."
+
+ ::= { dcmim2ControlSystem 1 }
+
+dcmim2ControlRunCapacityBatteryTest OBJECT-TYPE
+ SYNTAX INTEGER {
+ battTestOff (1),
+ battTestOn (2)
+}
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this OID will return the battery capacity test state. If
+ the test is off, the battTestOff (1) value will be returned.
+ If the test is on, the battTestOn (2) value will be
+ returned.
+
+ Setting this OID to battTestOff (1) will turn the battery capacity test off.
+ Setting this OID to battTestOn (2) will turn the battery capacity test on."
+
+ ::= { dcmim2ControlSystem 2 }
+
+
+-- the dcmim2ConfigSystem group
+
+dcmim2ConfigSysHighTempTrip OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Trip level (threshold) at which System High Temp alarm condition is created.
+ Range 28 to 100 (degC).
+
+ Values are represented in thousandths of a degree.
+ Units are displayed in the scale shown in
+ the 'dcmim2StatusSysTempUnits' OID (Celsius or Fahrenheit)."
+
+
+ ::= { dcmim2ConfigSystem 1 }
+
+dcmim2ConfigSysHighTempReset OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Level at which System High Temp alarm condition is reset (cleared).
+ Range 25 to (upper temp - 3) (degC).
+
+ Values are represented in thousandths of a degree.
+ Units are displayed in the scale shown in
+ the 'dcmim2StatusSysTempUnits' OID (Celsius or Fahrenheit)."
+
+ ::= { dcmim2ConfigSystem 2 }
+
+dcmim2ConfigSysLowTempTrip OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Trip level (threshold) at which System Low Temp alarm condition is created.
+ Range -100 to 10 (degC).
+ Values are represented in thousandths of a degree.
+ Units are displayed in the scale shown in
+ the 'dcmim2StatusSysTempUnits' OID (Celsius or Fahrenheit)."
+
+ ::= { dcmim2ConfigSystem 3 }
+
+dcmim2ConfigSysLowTempReset OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Level at which System Low Temp alarm condition is reset (cleared).
+ Range (lower temp + 3) to 13 (degC).
+ Values are represented in thousandths of a degree.
+ Units are displayed in the scale shown in
+ the 'dcmim2StatusSysTempUnits' OID (Celsius or Fahrenheit)."
+
+ ::= { dcmim2ConfigSystem 4 }
+
+-- the dcmim2ConfigBattery group
+
+dcmim2ConfigBattFloatVolt OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Battery Float Voltage defined at 25 degrees Celsius.
+
+ Values are represented in thousandths of Volts (mV)."
+
+ ::= { dcmim2ConfigBattery 1 }
+
+dcmim2ConfigBattMaxRecharge OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Battery Maximum Recharge Rate. This is the maximum current used
+ during battery charging.
+
+ Values are represented in thousandths of Amps (mA)."
+
+ ::= { dcmim2ConfigBattery 2 }
+
+dcmim2ConfigBattMfgCapacity OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Battery capacity (Amp-Hour Size) as specified by the battery manufacturer.
+
+ Values are represented in thousandths of Amp hours (mAHr)."
+
+ ::= { dcmim2ConfigBattery 3 }
+
+dcmim2ConfigBattType OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Type of battery in the powerplant
+
+ Valid values range from 0 to 254."
+
+ ::= { dcmim2ConfigBattery 4 }
+
+dcmim2ConfigBattFunctTestDuration OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Duration of the battery functional test.
+
+ Values are represented in thousandths of seconds (mSecs)."
+
+ ::= { dcmim2ConfigBattery 5 }
+
+dcmim2ConfigBattFunctTestThresh OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Threshold the battery voltage of the system must remain above
+ in order to pass the battery functional test.
+
+ Values are represented in thousandths of Volts (mV)."
+
+ ::= { dcmim2ConfigBattery 6 }
+
+dcmim2ConfigBattCapacityTestPercent OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Threshold for good battery capacity test results.
+
+ Values range from 0 to 100 percent."
+
+ ::= { dcmim2ConfigBattery 7 }
+
+dcmim2ConfigBattCapacityTestEndThresh OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Safeguard voltage at which battery capacity test will end
+ if there is a battery problem.
+
+ Values are represented in thousandths of Volts (mV)."
+
+ ::= { dcmim2ConfigBattery 8 }
+
+dcmim2ConfigBattCapacityTestCurrent OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Constant current value used during battery capacity testing.
+
+ Values are represented in thousandths of Amps (mA)."
+
+ ::= { dcmim2ConfigBattery 9 }
+
+
+-- the dcmim2ConfigLVD group
+
+dcmim2ConfigLVDTableSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of DC powerplant LVDs controllable
+ by this IP address."
+ ::= { dcmim2ConfigLVD 1 }
+
+dcmim2ConfigLVDTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF DC2ConfigLVDEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for accessing settings of the LVDs. The number of
+ entries is contained in the dcmim2ConfigLVDTableSize OID."
+ ::= { dcmim2ConfigLVD 2 }
+
+dcmim2ConfigLVDEntry OBJECT-TYPE
+ SYNTAX DC2ConfigLVDEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The LVD to configure."
+ INDEX { dcmim2ConfigLVDIndex }
+ ::= { dcmim2ConfigLVDTable 1 }
+
+DC2ConfigLVDEntry ::=
+ SEQUENCE {
+ dcmim2ConfigLVDIndex INTEGER,
+ dcmim2ConfigLVDTrip INTEGER,
+ dcmim2ConfigLVDReset INTEGER,
+ dcmim2ConfigLVDState INTEGER
+ }
+
+dcmim2ConfigLVDIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the DC powerplant LVD."
+ ::= { dcmim2ConfigLVDEntry 1 }
+
+dcmim2ConfigLVDTrip OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "LVD Trip threshold. System bus voltage at which LVD will trip (open)
+ during a battery backup operation.
+
+ Values are represented in thousandths of Volts (mV)."
+ ::= { dcmim2ConfigLVDEntry 2 }
+
+dcmim2ConfigLVDReset OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "LVD Reset threshold. System bus voltage at which LVD will reset (close)
+ after AC power has been restored.
+
+ Values are represented in thousandths of Volts (mV)."
+ ::= { dcmim2ConfigLVDEntry 3 }
+
+dcmim2ConfigLVDState OBJECT-TYPE
+ SYNTAX INTEGER {
+ statusClosed (1),
+ statusOpened (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this OID will return statusClosed (1) if the LVD is closed.
+ statusOpened (2) will be returned if the LVD is opened."
+ ::= { dcmim2ConfigLVDEntry 4 }
+
+
+-- the dcmim2StatusSystem group
+
+dcmim2StatusSysRectCurrent OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "System (Total Rectifier) current in thousandths of Amps (mA)."
+ ::= { dcmim2StatusSystem 1 }
+
+dcmim2StatusSysLoadCurrent OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Load current in thousandths of Amps (mA)."
+ ::= { dcmim2StatusSystem 2 }
+
+dcmim2StatusSysBusVoltage OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "System bus voltage in thousandths of Volts (mV)."
+ ::= { dcmim2StatusSystem 3 }
+
+dcmim2StatusSysAmbientTemp OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "System temperature based on sensor on Master Controller PCB.
+
+ Values are represented in thousandths of a degree.
+ Units are displayed in the scale shown in
+ the 'dcmim2StatusSysTempUnits' OID (Celsius or Fahrenheit)."
+ ::= { dcmim2StatusSystem 4 }
+
+dcmim2StatusSysUpTime OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Length of time since the DC Powerplant controller has been powered up."
+ ::= { dcmim2StatusSystem 5 }
+
+dcmim2StatusSysTempUnits OBJECT-TYPE
+ SYNTAX INTEGER {
+ celsius(1),
+ fahrenheit(2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The temperature scale used to display the temperature
+ in the DC system, Celsius(1) or Fahrenheit(2).
+ This setting is based on the system preferences
+ configuration in the agent."
+ ::= { dcmim2StatusSystem 6 }
+
+
+-- the dcmim2StatusRectifier group
+
+dcmim2StatusRectTableSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of DC powerplant rectifiers viewable
+ by this IP address."
+ ::= { dcmim2StatusRectifier 1 }
+
+dcmim2StatusRectTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF DC2StatusRectEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for accessing settings of the rectifiers. The number of
+ entries is contained in the dcmim2StatusRectTableSize OID."
+ ::= { dcmim2StatusRectifier 2 }
+
+dcmim2StatusRectEntry OBJECT-TYPE
+ SYNTAX DC2StatusRectEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The rectifier to gather status from."
+ INDEX { dcmim2StatusRectIndex }
+ ::= { dcmim2StatusRectTable 1 }
+
+DC2StatusRectEntry ::=
+ SEQUENCE {
+ dcmim2StatusRectIndex INTEGER,
+ dcmim2StatusRectDevType INTEGER,
+ dcmim2StatusRectID INTEGER,
+ dcmim2StatusRectPhyAddr INTEGER,
+ dcmim2StatusRectFail INTEGER,
+ dcmim2StatusRectCurrent INTEGER
+ }
+
+dcmim2StatusRectIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the DC powerplant rectifier."
+ ::= { dcmim2StatusRectEntry 1 }
+
+dcmim2StatusRectDevType OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This OID shows the rectifier device type."
+ ::= { dcmim2StatusRectEntry 2 }
+
+dcmim2StatusRectID OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This OID shows the rectifier ID. This enumerates the number of the rectifier within
+ a group of rectifiers."
+ ::= { dcmim2StatusRectEntry 3 }
+
+dcmim2StatusRectPhyAddr OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This OID shows the rectifier physical address (the address on the bus)."
+ ::= { dcmim2StatusRectEntry 4 }
+
+dcmim2StatusRectFail OBJECT-TYPE
+ SYNTAX INTEGER {
+ statusTrue (1),
+ statusFalse (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this OID will return statusTrue (1) if the rectifier has failed.
+ statusFalse (2) will be returned if the rectifier has not failed."
+ ::= { dcmim2StatusRectEntry 5 }
+
+dcmim2StatusRectCurrent OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This OID shows the individual rectifier current in thousandths of Amps (mA)."
+ ::= { dcmim2StatusRectEntry 6 }
+
+
+-- the dcmim2StatusBattery group
+
+dcmim2StatusBattFloatVolt OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Battery Float Voltage represented in thousandths of Volts (mV)."
+ ::= { dcmim2StatusBattery 1 }
+
+dcmim2StatusBattCurrent OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Battery Current: This OID shows the battery current in thousandths of Amps (mA)."
+ ::= { dcmim2StatusBattery 2 }
+
+dcmim2StatusBattTemp OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Battery Temperature:
+
+ Values are represented in thousandths of a degree.
+ Units are displayed in the scale shown in
+ the 'dcmim2StatusSysTempUnits' OID (Celsius or Fahrenheit)."
+ ::= { dcmim2StatusBattery 3 }
+
+dcmim2StatusBattMfgCapacity OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Battery capacity (Amp-Hour Size) as specified by the battery manufacturer.
+ Values are represented in thousandths of Amp hours (mAHr)."
+ ::= { dcmim2StatusBattery 4 }
+
+dcmim2StatusBattTestCapacity OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Battery capacity (Amp-Hour Size) as determined by the battery capacity test.
+ Values are represented in thousandths of Amp hours (mAHr)."
+ ::= { dcmim2StatusBattery 5 }
+
+dcmim2StatusBattFunctTestResult OBJECT-TYPE
+ SYNTAX INTEGER{
+ functTestNotPerformed (1),
+ functTestInProcess (2),
+ functTestInterrupted (3),
+ functTestPass (4),
+ functTestFail (5)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Results of the last battery functional test that was run."
+ ::= { dcmim2StatusBattery 6 }
+
+dcmim2StatusBattCapacityTestResult OBJECT-TYPE
+ SYNTAX INTEGER{
+ capacityTestNotPerformed (1),
+ capacityTestInProcess (2),
+ capacityTestInterrupted (3),
+ capacityTestPass (4),
+ capacityTestFail (5)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Results of the last battery capacity test that was run."
+ ::= { dcmim2StatusBattery 7 }
+
+
+-- the dcmim2StatusLVD group
+
+dcmim2StatusLVDTableSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of DC powerplant LVDs accessible
+ by this IP address."
+ ::= { dcmim2StatusLVD 1 }
+
+dcmim2StatusLVDTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF DC2StatusLVDEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for accessing the LVDs. The number of
+ entries is contained in the dcmim2StatusLVDTableSize OID."
+ ::= { dcmim2StatusLVD 2 }
+
+dcmim2StatusLVDEntry OBJECT-TYPE
+ SYNTAX DC2StatusLVDEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The LVD to access."
+ INDEX { dcmim2StatusLVDIndex }
+ ::= { dcmim2StatusLVDTable 1 }
+
+DC2StatusLVDEntry ::=
+ SEQUENCE {
+ dcmim2StatusLVDIndex INTEGER,
+ dcmim2StatusLVDState INTEGER
+ }
+
+dcmim2StatusLVDIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the DC powerplant LVD."
+ ::= { dcmim2StatusLVDEntry 1 }
+
+dcmim2StatusLVDState OBJECT-TYPE
+ SYNTAX INTEGER {
+ statusClosed (1),
+ statusOpened (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this OID will return statusClosed (1) if the LVD is closed.
+ statusOpened (2) will be returned if the LVD is opened."
+ ::= { dcmim2StatusLVDEntry 2 }
+
+
+-- the dcmim2StatusAlarms group
+
+dcmim2StatusAlarmsTableSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of DC powerplant alarms viewable
+ by this IP address."
+ ::= { dcmim2StatusAlarms 1 }
+
+dcmim2StatusAlarmsTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF DC2StatusAlarmsEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for accessing system alarms. The number of
+ entries is contained in the dcmim2StatusAlarmsTableSize OID."
+ ::= { dcmim2StatusAlarms 2 }
+
+dcmim2StatusAlarmsEntry OBJECT-TYPE
+ SYNTAX DC2StatusAlarmsEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The alarm to display."
+ INDEX { dcmim2StatusAlarmsIndex }
+ ::= { dcmim2StatusAlarmsTable 1 }
+
+DC2StatusAlarmsEntry ::=
+ SEQUENCE {
+ dcmim2StatusAlarmsIndex INTEGER,
+ dcmim2StatusAlarmsText DisplayString
+ }
+
+dcmim2StatusAlarmsIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index of the system alarm."
+ ::= { dcmim2StatusAlarmsEntry 1 }
+
+dcmim2StatusAlarmsText OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The 16 character text describing the active alarm condition."
+ ::= { dcmim2StatusAlarmsEntry 2 }
+
+-- External Environmental Monitor
+
+emIdentFirmwareRevision OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The firmware revision of the Environmental Monitor."
+ ::= { emIdent 1 }
+
+emConfigProbesNumProbes OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of temperature and humidity probes available."
+ ::= { emConfig 1 }
+
+emConfigProbesTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF EmConfigProbesEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A list of probes supported by the Environmental Monitor
+ and their configurations."
+ ::= { emConfig 2 }
+
+emConfigProbesEntry OBJECT-TYPE
+ SYNTAX EmConfigProbesEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The Environmental Monitor probe configurations."
+ INDEX { emConfigProbeNumber }
+ ::= { emConfigProbesTable 1 }
+
+EmConfigProbesEntry ::=
+ SEQUENCE {
+ emConfigProbeNumber
+ INTEGER,
+ emConfigProbeName
+ DisplayString,
+ emConfigProbeHighTempThreshold
+ INTEGER,
+ emConfigProbeLowTempThreshold
+ INTEGER,
+ emConfigProbeTempUnits
+ INTEGER,
+ emConfigProbeHighHumidThreshold
+ INTEGER,
+ emConfigProbeLowHumidThreshold
+ INTEGER,
+ emConfigProbeHighTempEnable
+ INTEGER,
+ emConfigProbeLowTempEnable
+ INTEGER,
+ emConfigProbeHighHumidEnable
+ INTEGER,
+ emConfigProbeLowHumidEnable
+ INTEGER
+ }
+
+emConfigProbeNumber OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index into an Environmental Monitor probe entry."
+ ::= { emConfigProbesEntry 1 }
+
+emConfigProbeName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "A descriptive name of the probe set by the user,
+ possibly denoting its location or purpose."
+ ::= { emConfigProbesEntry 2 }
+
+emConfigProbeHighTempThreshold OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The high temperature alarm threshold for the probe.
+ Units are displayed in the scale selected in
+ the 'emConfigProbeTempUnits' OID (Celsius or Fahrenheit)."
+ ::= { emConfigProbesEntry 3 }
+
+emConfigProbeLowTempThreshold OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The low temperature alarm threshold for the probe.
+ Units are displayed in the scale selected in
+ the 'emConfigProbeTempUnits' OID (Celsius or Fahrenheit)."
+ ::= { emConfigProbesEntry 4 }
+
+emConfigProbeTempUnits OBJECT-TYPE
+ SYNTAX INTEGER {
+ celsius(1),
+ fahrenheit(2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The temperature scale used to display the temperature
+ thresholds of the probe, Celsius(1) or Fahrenheit(2).
+ This setting is based on the system preferences
+ configuration in the agent."
+ ::= { emConfigProbesEntry 5 }
+
+emConfigProbeHighHumidThreshold OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The high humidity alarm threshold for the probe in
+ percent relative humidity."
+ ::= { emConfigProbesEntry 6 }
+
+emConfigProbeLowHumidThreshold OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The low humidity alarm threshold for the probe in
+ percent relative humidity."
+ ::= { emConfigProbesEntry 7 }
+
+emConfigProbeHighTempEnable OBJECT-TYPE
+ SYNTAX INTEGER {
+ disabled(1),
+ enabled(2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The high temperature alarm enable/disable for the
+ probe. No alarm will be generated if this value
+ is set to disabled(1). The alarm will be
+ generated if this value is set to enabled(2) and
+ the threshold has been violated."
+ ::= { emConfigProbesEntry 8 }
+
+emConfigProbeLowTempEnable OBJECT-TYPE
+ SYNTAX INTEGER {
+ disabled(1),
+ enabled(2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The low temperature alarm enable/disable for the
+ probe. No alarm will be generated if this value
+ is set to disabled(1). The alarm will be
+ generated if this value is set to enabled(2) and
+ the threshold has been violated."
+ ::= { emConfigProbesEntry 9 }
+
+emConfigProbeHighHumidEnable OBJECT-TYPE
+ SYNTAX INTEGER {
+ disabled(1),
+ enabled(2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The high humidity alarm enable/disable for the
+ probe. No alarm will be generated if this value
+ is set to disabled(1). The alarm will be
+ generated if this value is set to enabled(2) and
+ the threshold has been violated."
+ ::= { emConfigProbesEntry 10 }
+
+emConfigProbeLowHumidEnable OBJECT-TYPE
+ SYNTAX INTEGER {
+ disabled(1),
+ enabled(2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The low humidity alarm enable/disable for the
+ probe. No alarm will be generated if this value
+ is set to disabled(1). The alarm will be
+ generated if this value is set to enabled(2) and
+ the threshold has been violated."
+ ::= { emConfigProbesEntry 11 }
+
+emConfigContactsNumContacts OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of contacts supported by the Environmental
+ Monitor."
+ ::= { emConfig 3 }
+
+emConfigContactsTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF EmConfigContactsEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A list of contacts supported by the Environmental Monitor
+ and their configurations."
+ ::= { emConfig 4 }
+
+emConfigContactsEntry OBJECT-TYPE
+ SYNTAX EmConfigContactsEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The Environmental Monitor contact configurations."
+ INDEX { emConfigContactNumber }
+ ::= { emConfigContactsTable 1 }
+
+EmConfigContactsEntry ::=
+ SEQUENCE {
+ emConfigContactNumber
+ INTEGER,
+ emConfigContactName
+ DisplayString,
+ emConfigContactEnable
+ INTEGER
+ }
+
+emConfigContactNumber OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index of an Environmental Monitor contact."
+ ::= { emConfigContactsEntry 1 }
+
+emConfigContactName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "A descriptive name for an Environmental Monitor
+ contact set by the user, possibly denoting its
+ location or purpose."
+ ::= { emConfigContactsEntry 2 }
+
+emConfigContactEnable OBJECT-TYPE
+ SYNTAX INTEGER {
+ disabled(1),
+ enabled(2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "An Environmental Monitor contact alarm enable/disable.
+ No alarm will be generated if the contact is disabled(1).
+ An alarm will be generated if the contact is enabled(2)
+ and the contact has been faulted."
+ ::= { emConfigContactsEntry 3 }
+
+emStatusCommStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ noComm(1),
+ comm(2),
+ commLost(3)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The communication status between the agent
+ and the Environmental Monitor.
+
+ noComm(1), Communication has never been established.
+ comm(2), Communication has been established.
+ commLost(3), Communication was established, but was lost."
+ ::= { emStatus 1 }
+
+emStatusProbesNumProbes OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of available probes on the Environmental
+ Monitor."
+ ::= { emStatus 2 }
+
+emStatusProbesTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF EmStatusProbesEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A list of probes supported by the Environmental Monitor
+ and their status."
+ ::= { emStatus 3 }
+
+emStatusProbesEntry OBJECT-TYPE
+ SYNTAX EmStatusProbesEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The status of the probe."
+ INDEX { emStatusProbeNumber }
+ ::= { emStatusProbesTable 1 }
+
+EmStatusProbesEntry ::=
+ SEQUENCE {
+ emStatusProbeNumber
+ INTEGER,
+ emStatusProbeName
+ DisplayString,
+ emStatusProbeStatus
+ INTEGER,
+ emStatusProbeCurrentTemp
+ INTEGER,
+ emStatusProbeTempUnits
+ INTEGER,
+ emStatusProbeCurrentHumid
+ INTEGER,
+ emStatusProbeHighTempViolation
+ INTEGER,
+ emStatusProbeLowTempViolation
+ INTEGER,
+ emStatusProbeHighHumidViolation
+ INTEGER,
+ emStatusProbeLowHumidViolation
+ INTEGER
+ }
+
+emStatusProbeNumber OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index of the probe."
+ ::= { emStatusProbesEntry 1 }
+
+emStatusProbeName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A descriptive name for the probe set by the user,
+ possibly denoting its location or purpose."
+ ::= { emStatusProbesEntry 2 }
+
+emStatusProbeStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ disconnected(1),
+ connected(2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The connected status of the probe, either
+ disconnected(1) or connected(2)."
+ ::= { emStatusProbesEntry 3 }
+
+emStatusProbeCurrentTemp OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The current temperature reading from the probe displayed
+ in the units shown in the 'emStatusProbeTempUnits' OID
+ (Celsius or Fahrenheit)."
+ ::= { emStatusProbesEntry 4 }
+
+emStatusProbeTempUnits OBJECT-TYPE
+ SYNTAX INTEGER {
+ celsius(1),
+ fahrenheit(2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The temperature scale used to display the temperature
+ thresholds of the probe, Celsius(1) or Fahrenheit(2).
+ This setting is based on the system preferences
+ configuration in the agent."
+ ::= { emStatusProbesEntry 5 }
+
+emStatusProbeCurrentHumid OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The current humidity reading from the probe in
+ percent relative humidity."
+ ::= { emStatusProbesEntry 6 }
+
+emStatusProbeHighTempViolation OBJECT-TYPE
+ SYNTAX INTEGER {
+ noViolation(1),
+ highTempViolation(2),
+ disabled(3)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The high temperature violation status of the probe
+ temperature reading. This OID will show a highTempViolation(2)
+ if the current temperature reading shown in the
+ 'emStatusProbeCurrentTemp' OID is greater than or equal to
+ the high temperature threshold value, the
+ 'emConfigProbeHighTempThreshold' OID, and the value of the
+ 'emConfigProbeHighTempEnable' OID is enabled. Otherwise it will show
+ noViolation(1). If the 'emConfigProbeHighTempEnable' OID is disabled,
+ this OID will show disabled(3)."
+ ::= { emStatusProbesEntry 7 }
+
+emStatusProbeLowTempViolation OBJECT-TYPE
+ SYNTAX INTEGER {
+ noViolation(1),
+ lowTempViolation(2),
+ disabled(3)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The high temperature violation status of the probe
+ temperature reading. This OID will show a lowTempViolation(2)
+ if the current temperature reading shown in the
+ 'emStatusProbeCurrentTemp' OID is less than or equal to
+ the low temperature threshold value, the
+ 'emConfigProbeLowTempThreshold' OID, and the value of the
+ 'emConfigProbeLowTempEnable' OID is enabled. Otherwise it will show
+ noViolation(1). If the 'emConfigProbeLowTempEnable' OID is disabled,
+ this OID will show disabled(3)."
+ ::= { emStatusProbesEntry 8 }
+
+emStatusProbeHighHumidViolation OBJECT-TYPE
+ SYNTAX INTEGER {
+ noViolation(1),
+ highHumidViolation(2),
+ disabled(3)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The high humidity violation status of the probe humidity
+ reading. This OID will show a highTempViolation(2)
+ if the current humidity reading shown in the
+ 'emStatusProbeCurrentHumid' OID is greater than or equal to
+ the high humidity threshold value, the
+ 'emConfigProbeHighHumidThreshold' OID, and the value of the
+ 'emConfigProbeHighHumidEnable' OID is enabled. Otherwise it will
+ show noViolation(1). If the 'emConfigProbeHighHumidEnable' OID is
+ disabled, this OID will show disabled(3)"
+ ::= { emStatusProbesEntry 9 }
+
+emStatusProbeLowHumidViolation OBJECT-TYPE
+ SYNTAX INTEGER {
+ noViolation(1),
+ lowHumidViolation(2),
+ disabled(3)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The low humidity violation status of the probe humidity
+ reading. This OID will show a lowTempViolation(2)
+ if the current humidity reading shown in the
+ 'emStatusProbeCurrentHumid' OID is less than or equal to
+ the low humidity threshold value, the
+ 'emConfigProbeLowHumidThreshold' OID, and the value of the
+ 'emConfigProbeLowHumidEnable' OID is enabled. Otherwise it will
+ show noViolation(1). If the 'emConfigProbeLowHumidEnable' OID is
+ disabled, this OID will show disabled(3)."
+ ::= { emStatusProbesEntry 10 }
+
+emStatusContactsNumContacts OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of contacts supported by the
+ Environmental Monitor."
+ ::= { emStatus 4 }
+
+emStatusContactsTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF EmStatusContactsEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A list of contacts supported by the Environmental Monitor
+ and their status."
+ ::= { emStatus 5 }
+
+emStatusContactsEntry OBJECT-TYPE
+ SYNTAX EmStatusContactsEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The status of the contact."
+ INDEX { emStatusContactNumber }
+ ::= { emStatusContactsTable 1 }
+
+EmStatusContactsEntry ::=
+ SEQUENCE {
+ emStatusContactNumber
+ INTEGER,
+ emStatusContactName
+ DisplayString,
+ emStatusContactStatus
+ INTEGER
+ }
+
+emStatusContactNumber OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index of the Environmental Monitor contact."
+ ::= { emStatusContactsEntry 1 }
+
+emStatusContactName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A descriptive name for the Environmental Monitor contact
+ set by the user, possibly denoting its location or purpose."
+ ::= { emStatusContactsEntry 2 }
+
+emStatusContactStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ noFault(1),
+ fault(2),
+ disabled(3)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The status of the Environmental Monitor contact. The status
+ will show noFault(1) if the contact is in the normal state
+ and the 'emConfigContactEnable' OID is enabled. The status will
+ show a fault(2) if the contact is faulted and the
+ 'emContactEnable' OID is enabled. If the 'emConfigContactEnable'
+ OID is disabled, the status will show disabled(3)."
+ ::= { emStatusContactsEntry 3 }
+
+-- Integrated Environmental Monitor (IEM)
+
+iemIdentHardwareRevision OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The hardware revision of the Integrated Environmental
+ Monitor."
+ ::= { iemIdent 1 }
+
+iemConfigProbesNumProbes OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of temperature and humidity probes available."
+ ::= { iemConfig 1 }
+
+iemConfigProbesTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF IemConfigProbesEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A list of probes supported by the Environmental Monitor
+ and their configurations."
+ ::= { iemConfig 2 }
+
+iemConfigProbesEntry OBJECT-TYPE
+ SYNTAX IemConfigProbesEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The Environmental Monitor probe configurations."
+ INDEX { iemConfigProbeNumber }
+ ::= { iemConfigProbesTable 1 }
+
+IemConfigProbesEntry ::=
+ SEQUENCE {
+ iemConfigProbeNumber
+ INTEGER,
+ iemConfigProbeName
+ DisplayString,
+ iemConfigProbeHighTempThreshold
+ INTEGER,
+ iemConfigProbeLowTempThreshold
+ INTEGER,
+ iemConfigProbeTempUnits
+ INTEGER,
+ iemConfigProbeHighHumidThreshold
+ INTEGER,
+ iemConfigProbeLowHumidThreshold
+ INTEGER,
+ iemConfigProbeHighTempEnable
+ INTEGER,
+ iemConfigProbeLowTempEnable
+ INTEGER,
+ iemConfigProbeHighHumidEnable
+ INTEGER,
+ iemConfigProbeLowHumidEnable
+ INTEGER
+ }
+
+iemConfigProbeNumber OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to a Environmental Monitor probe entry."
+ ::= { iemConfigProbesEntry 1 }
+
+iemConfigProbeName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "A descriptive name for the probe set by the user,
+ possibly denoting its location or purpose."
+ ::= { iemConfigProbesEntry 2 }
+
+iemConfigProbeHighTempThreshold OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The high temperature alarm threshold for the probe.
+ Units are displayed in the scale selected in the
+ 'iemConfigProbeTempUnits' OID (Celsius or Fahrenheit)."
+ ::= { iemConfigProbesEntry 3 }
+
+iemConfigProbeLowTempThreshold OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The low temperature alarm threshold for the probe.
+ Units are displayed in the scale selected in the
+ 'iemConfigProbeTempUnits' OID (Celsius or Fahrenheit)."
+ ::= { iemConfigProbesEntry 4 }
+
+iemConfigProbeTempUnits OBJECT-TYPE
+ SYNTAX INTEGER {
+ celsius(1),
+ fahrenheit(2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The temperature scale used to display the temperature
+ thresholds of the probe, Celsius(1) or Fahrenheit(2).
+ This setting is based on the system preferences
+ configuration in the agent."
+ ::= { iemConfigProbesEntry 5 }
+
+iemConfigProbeHighHumidThreshold OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The high humidity alarm threshold for the probe in
+ percent relative humidity."
+ ::= { iemConfigProbesEntry 6 }
+
+iemConfigProbeLowHumidThreshold OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The low humidity alarm threshold for the probe in
+ percent relative humidity."
+ ::= { iemConfigProbesEntry 7 }
+
+iemConfigProbeHighTempEnable OBJECT-TYPE
+ SYNTAX INTEGER {
+ disabled(1),
+ enabled(2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The high temperature alarm enable/disable for the
+ probe. No alarm will be generated if this value
+ is set to disabled(1). The alarm will be
+ generated if this value is set to enabled(2) and
+ the threshold has been violated."
+ ::= { iemConfigProbesEntry 8 }
+
+iemConfigProbeLowTempEnable OBJECT-TYPE
+ SYNTAX INTEGER {
+ disabled(1),
+ enabled(2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The low temperature alarm enable/disable for the
+ probe. No alarm will be generated if this value
+ is set to disabled(1). The alarm will be
+ generated if this value is set to enabled(2) and
+ the threshold has been violated."
+ ::= { iemConfigProbesEntry 9 }
+
+iemConfigProbeHighHumidEnable OBJECT-TYPE
+ SYNTAX INTEGER {
+ disabled(1),
+ enabled(2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The high humidity alarm enable/disable for the
+ probe. No alarm will be generated if this value
+ is set to disabled(1). The alarm will be
+ generated if this value is set to enabled(2) and
+ the threshold has been violated."
+ ::= { iemConfigProbesEntry 10 }
+
+iemConfigProbeLowHumidEnable OBJECT-TYPE
+ SYNTAX INTEGER {
+ disabled(1),
+ enabled(2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The low humidity alarm enable/disable for the
+ probe. No alarm will be generated if this value
+ is set to disabled(1). The alarm will be
+ generated if this value is set to enabled(2) and
+ the threshold has been violated."
+ ::= { iemConfigProbesEntry 11 }
+
+iemConfigContactsNumContacts OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of contacts available on the Environmental
+ Monitor."
+ ::= { iemConfig 3 }
+
+iemConfigContactsTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF IemConfigContactsEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A list of contacts supported by the Environmental Monitor
+ and their configurations."
+ ::= { iemConfig 4 }
+
+iemConfigContactsEntry OBJECT-TYPE
+ SYNTAX IemConfigContactsEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The Environmental Monitor contact configurations."
+ INDEX { iemConfigContactNumber }
+ ::= { iemConfigContactsTable 1 }
+
+IemConfigContactsEntry ::=
+ SEQUENCE {
+ iemConfigContactNumber
+ INTEGER,
+ iemConfigContactName
+ DisplayString,
+ iemConfigContactEnable
+ INTEGER
+ }
+
+iemConfigContactNumber OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index of an Environmental Monitor contact."
+ ::= { iemConfigContactsEntry 1 }
+
+iemConfigContactName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "A descriptive name for the Environmental Monitor contact
+ set by the user, possibly denoting its location or purpose."
+ ::= { iemConfigContactsEntry 2 }
+
+iemConfigContactEnable OBJECT-TYPE
+ SYNTAX INTEGER {
+ disabled(1),
+ enabled(2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "An Environmental Monitor contact alarm enable/disable."
+ ::= { iemConfigContactsEntry 3 }
+
+
+iemStatusProbesNumProbes OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of available probes on the Environmental
+ Monitor."
+ ::= { iemStatus 1 }
+
+iemStatusProbesTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF IemStatusProbesEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A list of probes supported by the Environmental Monitor
+ and their status."
+ ::= { iemStatus 2 }
+
+iemStatusProbesEntry OBJECT-TYPE
+ SYNTAX IemStatusProbesEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The status of the probe."
+ INDEX { iemStatusProbeNumber }
+ ::= { iemStatusProbesTable 1 }
+
+IemStatusProbesEntry ::=
+ SEQUENCE {
+ iemStatusProbeNumber
+ INTEGER,
+ iemStatusProbeName
+ DisplayString,
+ iemStatusProbeStatus
+ INTEGER,
+ iemStatusProbeCurrentTemp
+ INTEGER,
+ iemStatusProbeTempUnits
+ INTEGER,
+ iemStatusProbeCurrentHumid
+ INTEGER,
+ iemStatusProbeHighTempViolation
+ INTEGER,
+ iemStatusProbeLowTempViolation
+ INTEGER,
+ iemStatusProbeHighHumidViolation
+ INTEGER,
+ iemStatusProbeLowHumidViolation
+ INTEGER
+ }
+
+iemStatusProbeNumber OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index of the probe."
+ ::= { iemStatusProbesEntry 1 }
+
+iemStatusProbeName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A descriptive name for the probe set by the user,
+ denoting its location or purpose."
+ ::= { iemStatusProbesEntry 2 }
+
+iemStatusProbeStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ disconnected(1),
+ connected(2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The connected status of the probe, either
+ disconnected(1) or connected(2)."
+ ::= { iemStatusProbesEntry 3 }
+
+iemStatusProbeCurrentTemp OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The current temperature reading from the probe displayed
+ in the units shown in the 'iemStatusProbeTempUnits' OID
+ (Celsius or Fahrenheit)."
+ ::= { iemStatusProbesEntry 4 }
+
+iemStatusProbeTempUnits OBJECT-TYPE
+ SYNTAX INTEGER {
+ celsius(1),
+ fahrenheit(2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The temperature scale used to display the temperature
+ thresholds of the probe, Celsius(1) or Fahrenheit(2).
+ This setting is based on the system preferences
+ configuration in the agent."
+ ::= { iemStatusProbesEntry 5 }
+
+iemStatusProbeCurrentHumid OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The current humidity reading from the probe in percent
+ relative humidity."
+ ::= { iemStatusProbesEntry 6 }
+
+iemStatusProbeHighTempViolation OBJECT-TYPE
+ SYNTAX INTEGER {
+ noViolation(1),
+ highTempViolation(2),
+ disabled(3)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The high temperature violation status of the probe
+ temperature reading. This OID will show a highTempViolation(2)
+ if the current temperature reading shown in the
+ 'iemStatusProbeCurrentTemp' OID is greater than or equal to
+ the high temperature threshold value, the
+ 'iemConfigProbeHighTempThreshold' OID, and the value of the
+ 'iemConfigProbeHighTempEnable' OID is enabled. Otherwise it will show
+ noViolation(1). If the 'iemConfigProbeHighTempEnable' OID is disabled,
+ this OID will show disabled(3)."
+ ::= { iemStatusProbesEntry 7 }
+
+iemStatusProbeLowTempViolation OBJECT-TYPE
+ SYNTAX INTEGER {
+ noViolation(1),
+ lowTempViolation(2),
+ disabled(3)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The high temperature violation status of the probe
+ temperature reading. This OID will show a lowTempViolation(2)
+ if the current temperature reading shown in the
+ 'iemStatusProbeCurrentTemp' OID is less than or equal to
+ the low temperature threshold value, the
+ 'iemConfigProbeLowTempThreshold' OID, and the value of the
+ 'iemPConfigrobeLowTempEnable' OID is enabled. Otherwise it will show
+ noViolation(1). If the 'iemConfigProbeLowTempEnable' OID is disabled,
+ this OID will show disabled(3)."
+ ::= { iemStatusProbesEntry 8 }
+
+iemStatusProbeHighHumidViolation OBJECT-TYPE
+ SYNTAX INTEGER {
+ noViolation(1),
+ highHumidViolation(2),
+ disabled(3)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The high humidity violation status of the probe humidity
+ reading. This OID will show a highTempViolation(2)
+ if the current humidity reading shown in the
+ 'iemStatusProbeCurrentHumid' OID is greater than or equal to
+ the high humidity threshold value, the
+ 'iemConfigProbeHighHumidThreshold' OID, and the value of the
+ 'iemConfigProbeHighHumidEnable' OID is enabled. Otherwise it will
+ show noViolation(1). If the 'iemConfigProbeHighHumidEnable' OID is
+ disabled, this OID will show disabled(3)."
+ ::= { iemStatusProbesEntry 9 }
+
+iemStatusProbeLowHumidViolation OBJECT-TYPE
+ SYNTAX INTEGER {
+ noViolation(1),
+ lowHumidViolation(2),
+ disabled(3)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The low humidity violation status of the probe humidity
+ reading. This OID will show a lowTempViolation(2)
+ if the current humidity reading shown in the
+ 'iemStatusProbeCurrentHumid' OID is less than or equal to
+ the low humidity threshold value, the
+ 'iemConfigProbeLowHumidThreshold' OID, and the value of the
+ 'iemConfigProbeLowHumidEnable' OID is enabled. Otherwise it will
+ show noViolation(1). If the 'iemConfigProbeLowHumidEnable' OID is
+ disabled, this OID will show disabled(3)."
+ ::= { iemStatusProbesEntry 10 }
+
+iemStatusContactsNumContacts OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of contacts supported on the
+ Environmental Monitor."
+ ::= { iemStatus 3 }
+
+iemStatusContactsTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF IemStatusContactsEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A list of contacts supported by the Environmental Monitor
+ and their status."
+ ::= { iemStatus 4 }
+
+iemStatusContactsEntry OBJECT-TYPE
+ SYNTAX IemStatusContactsEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The status of the contact."
+ INDEX { iemStatusContactNumber }
+ ::= { iemStatusContactsTable 1 }
+
+IemStatusContactsEntry ::=
+ SEQUENCE {
+ iemStatusContactNumber
+ INTEGER,
+ iemStatusContactName
+ DisplayString,
+ iemStatusContactStatus
+ INTEGER
+ }
+
+iemStatusContactNumber OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index of the Environmental Monitor contact."
+ ::= { iemStatusContactsEntry 1 }
+
+iemStatusContactName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A descriptive name for the Environmental Monitor contact
+ set by the user, denoting its location or purpose."
+ ::= { iemStatusContactsEntry 2 }
+
+iemStatusContactStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ noFault(1),
+ fault(2),
+ disabled(3)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The status of the Environmental Monitor contact. The status
+ will show noFault(1) if the contact is in the normal state
+ and the 'iemConfigContactEnable' OID is enabled. The status will
+ show a fault(2) if the contact is faulted and the
+ 'iemConfigContactEnable' OID is enabled. If the
+ 'iemConfigContactEnable' OID is disabled, the status will show
+ disabled(3)."
+ ::= { iemStatusContactsEntry 3 }
+
+iemStatusRelaysNumRelays OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of output relays supported on the
+ Environmental Monitor."
+ ::= { iemStatus 6 }
+
+iemStatusRelaysTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF IemStatusRelaysEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A list of output relays supported by the
+ Environmental Monitor and their status."
+ ::= { iemStatus 7 }
+
+iemStatusRelaysEntry OBJECT-TYPE
+ SYNTAX IemStatusRelaysEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The status of the relay."
+ INDEX { iemStatusRelayNumber }
+ ::= { iemStatusRelaysTable 1 }
+
+IemStatusRelaysEntry ::=
+ SEQUENCE {
+ iemStatusRelayNumber
+ INTEGER,
+ iemStatusRelayName
+ DisplayString,
+ iemStatusRelayStatus
+ INTEGER
+ }
+
+iemStatusRelayNumber OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index of the output relay."
+ ::= { iemStatusRelaysEntry 1 }
+
+iemStatusRelayName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A descriptive name for the output relay set by the
+ user, denoting its location or purpose."
+ ::= { iemStatusRelaysEntry 2 }
+
+iemStatusRelayStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ faultState(1),
+ normalState(2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The status of the output relay, either faultState(1) or
+ normalState(2)."
+ ::= { iemStatusRelaysEntry 3 }
+
+-- Environmental Management System (EMS)
+
+-- EMS IDENT
+
+emsIdentEMSName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A character string identifying the
+ device. "
+ ::= { emsIdent 1 }
+
+emsIdentProductNumber OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A character string identifying the model number of
+ the device. This value is set at the factory."
+ ::= { emsIdent 2 }
+
+emsIdentFirmwareRev OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The firmware revision of the device."
+ ::= { emsIdent 3 }
+
+emsIdentHardwareRev OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The hardware revision of the device.
+ This value is set at the factory."
+ ::= { emsIdent 4 }
+
+emsIdentDateOfManufacture OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The date when the device was manufactured in mm/dd/yyyy format.
+ This value is set at the factory. "
+ ::= { emsIdent 5 }
+
+emsIdentSerialNumber OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A character string identifying the serial number of
+ the device. This value is set at the factory."
+ ::= { emsIdent 6 }
+
+-- EMS CONTROL
+
+-- EMS OUTPUT RELAY CONTROL STATUS TABLE
+
+emsOutputRelayControlTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF OutputRelayControlEMSEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for control of individual output relays. The number of
+ entries is contained in the emsStatusOutputRelayCount OID."
+ ::= { emsOutputRelayControl 1 }
+
+emsOutputRelayControlEntry OBJECT-TYPE
+ SYNTAX OutputRelayControlEMSEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The output relays to control."
+ INDEX { emsOutputRelayControlOutputRelayIndex }
+ ::= { emsOutputRelayControlTable 1 }
+
+OutputRelayControlEMSEntry ::=
+ SEQUENCE {
+ emsOutputRelayControlOutputRelayIndex INTEGER,
+ emsOutputRelayControlOutputRelayName DisplayString,
+ emsOutputRelayControlOutputRelayCommand INTEGER
+ }
+
+emsOutputRelayControlOutputRelayIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the output relay entry."
+ ::= { emsOutputRelayControlEntry 1 }
+
+emsOutputRelayControlOutputRelayName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The name of the output relay.
+ This OID is provided for informational purposes only."
+ ::= { emsOutputRelayControlEntry 2 }
+
+emsOutputRelayControlOutputRelayCommand OBJECT-TYPE
+ SYNTAX INTEGER {
+ immediateCloseEMS (1),
+ immediateOpenEMS (2)
+ }
+
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this variable will return the output relay state. If
+ the output relay is closed, the immediateCloseEMS (1) value will be returned.
+ If the output relay is open, the immediateOpenEMS (2) value will be
+ returned.
+
+ Setting this variable to immediateCloseEMS (1) will immediately close the relay.
+
+ Setting this variable to immediateOpenEMS (2) will immediately open the relay."
+ ::= { emsOutputRelayControlEntry 3 }
+
+-- EMS OUTLET CONTROL TABLE
+
+emsOutletControlTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF OutletControlEMSEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for control of individual outlet switches. The number of
+ entries is contained in the emsStatusOutletCount OID."
+ ::= { emsOutletControl 1 }
+
+emsOutletControlEntry OBJECT-TYPE
+ SYNTAX OutletControlEMSEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The outlets to control."
+ INDEX { emsOutletControlOutletIndex }
+ ::= { emsOutletControlTable 1 }
+
+OutletControlEMSEntry ::=
+ SEQUENCE {
+ emsOutletControlOutletIndex INTEGER,
+ emsOutletControlOutletName DisplayString,
+ emsOutletControlOutletCommand INTEGER
+ }
+
+emsOutletControlOutletIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the outlet entry."
+ ::= { emsOutletControlEntry 1 }
+
+emsOutletControlOutletName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The name of the outlet.
+ This OID is provided for informational purposes only."
+ ::= { emsOutletControlEntry 2 }
+
+emsOutletControlOutletCommand OBJECT-TYPE
+ SYNTAX INTEGER {
+ immediateOnEMS (1),
+ immediateOffEMS (2)
+ }
+
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this variable will return the outlet state. If
+ the outlet is on, the immediateOnEMS (1) value will be returned.
+ If the outlet is off, the immediateOffEMS (2) value will be
+ returned.
+
+ Setting this variable to immediateOnEMS (1) will immediately turn the outlet on.
+
+ Setting this variable to immediateOffEMS (2) will immediately turn the outlet off."
+ ::= { emsOutletControlEntry 3 }
+
+-- EMS SENSOR CONTROL TABLE
+
+emsSensorControlTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF EMSSensorControlEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for control/reset of individual sensors. The number of
+ entries is contained in the emsStatusSensorCount OID."
+ ::= { emsSensorControl 1 }
+
+emsSensorControlEntry OBJECT-TYPE
+ SYNTAX EMSSensorControlEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The sensors to control/reset."
+ INDEX { emsSensorControlSensorIndex }
+ ::= { emsSensorControlTable 1 }
+
+EMSSensorControlEntry ::=
+ SEQUENCE {
+ emsSensorControlSensorIndex INTEGER,
+ emsSensorControlSensorSystemName DisplayString,
+ emsSensorControlSensorUserName DisplayString,
+ emsSensorControlSensorCommand INTEGER
+ }
+
+emsSensorControlSensorIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the sensor entry."
+ ::= { emsSensorControlEntry 1 }
+
+emsSensorControlSensorSystemName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The system name of the sensor. This describes the hardware system
+ intent of this sensor."
+ ::= { emsSensorControlEntry 2 }
+
+emsSensorControlSensorUserName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The name of the sensor as given by the system user."
+ ::= { emsSensorControlEntry 3 }
+
+emsSensorControlSensorCommand OBJECT-TYPE
+ SYNTAX INTEGER {
+ noCommandEMS (1),
+ resetCommandEMS (2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this variable will return noCommandEMS(1).
+
+ Setting this variable to resetCommandEMS(2) will issue a reset command to the
+ sensor. Some sensors cannot be manually reset and will not be affected
+ by this command."
+ ::= { emsSensorControlEntry 4 }
+
+-- EMS ALARM DEVICE CONTROL TABLE
+
+emsAlarmDeviceControlTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF AlarmDeviceControlEMSEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for control of individual alarm devices.
+ Note: Some alarm devices are not controllable. The number of
+ entries is contained in the emsStatusAlarmDeviceCount OID."
+ ::= { emsAlarmDeviceControl 1 }
+
+emsAlarmDeviceControlEntry OBJECT-TYPE
+ SYNTAX AlarmDeviceControlEMSEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The alarm devices to control."
+ INDEX { emsAlarmDeviceControlDeviceIndex }
+ ::= { emsAlarmDeviceControlTable 1 }
+
+AlarmDeviceControlEMSEntry ::=
+ SEQUENCE {
+ emsAlarmDeviceControlDeviceIndex INTEGER,
+ emsAlarmDeviceControlDeviceName DisplayString,
+ emsAlarmDeviceControlDeviceCommand INTEGER
+ }
+
+emsAlarmDeviceControlDeviceIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the alarm device entry."
+ ::= { emsAlarmDeviceControlEntry 1 }
+
+emsAlarmDeviceControlDeviceName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The name of the alarm device.
+ This OID is provided for informational purposes only."
+ ::= { emsAlarmDeviceControlEntry 2 }
+
+emsAlarmDeviceControlDeviceCommand OBJECT-TYPE
+ SYNTAX INTEGER {
+ alarmDeviceOnEMS (1),
+ alarmDeviceOffEMS (2),
+ alarmDeviceNotInstalledEMS (3)
+ }
+
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this variable will return the device state. If
+ the device is active, the alarmDeviceOnEMS (1) value will be returned.
+ If the device is inactive, the alarmDeviceOffEMS (2) value will be
+ returned. If the device is not installed, the
+ alarmDeviceNotInstalledEMS (3) value will be returned.
+
+ Actions resulting from setting this variable are device-dependent.
+
+ Setting this variable to alarmDeviceOnEMS (1) will turn that device (ex. Beacon) on.
+ Setting this variable to alarmDeviceOffEMS (2) will turn that device off."
+
+ ::= { emsAlarmDeviceControlEntry 3 }
+
+
+-- EMS CONFIG
+
+emsConfigName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The name of the device."
+ ::= { emsConfig 1 }
+
+emsConfigCheckLogLight OBJECT-TYPE
+ SYNTAX INTEGER {
+ lightDisabled (1),
+ lightOnInformational (2),
+ lightOnWarning (3),
+ lightOnSevere (4)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The setting of this OID determines the level of event that will
+ trigger the check-log light on the EMS. This is not available on the EMU2.
+
+ lightDisabled (1) disables the check-log light.
+ lightOnInformational (2) lights check-log for any event of
+ informational severity or above.
+ lightOnWarning (3) lights check-log for any event of
+ warning severity or above.
+ lightOnSevere (4) lights check-log for any event of severe severity."
+
+ ::= { emsConfig 2 }
+
+-- EMS PROBE CONFIG TABLE
+
+emsProbeConfigTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF EMSProbeConfigEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for configuration of individual probes. The number of
+ entries is contained in the emsStatusProbeCount OID."
+ ::= { emsProbeConfig 1 }
+
+emsProbeConfigEntry OBJECT-TYPE
+ SYNTAX EMSProbeConfigEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The probes to configure."
+ INDEX { emsProbeConfigProbeIndex }
+ ::= { emsProbeConfigTable 1 }
+
+EMSProbeConfigEntry ::=
+ SEQUENCE {
+ emsProbeConfigProbeIndex INTEGER,
+ emsProbeConfigProbeName DisplayString,
+ emsProbeConfigProbeHighTempThresh INTEGER,
+ emsProbeConfigProbeLowTempThresh INTEGER,
+ emsProbeConfigProbeHighHumidityThresh INTEGER,
+ emsProbeConfigProbeLowHumidityThresh INTEGER,
+ emsProbeConfigProbeMaxTempThresh INTEGER,
+ emsProbeConfigProbeMinTempThresh INTEGER,
+ emsProbeConfigProbeDeltaTemp INTEGER,
+ emsProbeConfigProbeMaxHumidityThresh INTEGER,
+ emsProbeConfigProbeMinHumidityThresh INTEGER,
+ emsProbeConfigProbeDeltaHumidity INTEGER,
+ emsProbeConfigProbeSTIncTempVariance INTEGER,
+ emsProbeConfigProbeSTIncTempTime INTEGER,
+ emsProbeConfigProbeSTDecTempVariance INTEGER,
+ emsProbeConfigProbeSTDecTempTime INTEGER,
+ emsProbeConfigProbeLTIncTempVariance INTEGER,
+ emsProbeConfigProbeLTIncTempTime INTEGER,
+ emsProbeConfigProbeLTDecTempVariance INTEGER,
+ emsProbeConfigProbeLTDecTempTime INTEGER
+ }
+
+emsProbeConfigProbeIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the probe entry."
+ ::= { emsProbeConfigEntry 1 }
+
+emsProbeConfigProbeName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The name of the probe."
+ ::= { emsProbeConfigEntry 2 }
+
+emsProbeConfigProbeHighTempThresh OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Probe high temperature threshold.
+
+ Values are represented in whole number degrees.
+ Units are displayed in the scale shown in
+ the emsStatusSysTempUnits OID (Celsius or Fahrenheit)."
+ ::= { emsProbeConfigEntry 3 }
+
+emsProbeConfigProbeLowTempThresh OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Probe low temperature threshold.
+
+ Values are represented in whole number degrees.
+ Units are displayed in the scale shown in
+ the emsStatusSysTempUnits OID (Celsius or Fahrenheit)."
+ ::= { emsProbeConfigEntry 4 }
+
+emsProbeConfigProbeHighHumidityThresh OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Probe high humidity threshold.
+
+ Values are represented in whole number percentage."
+ ::= { emsProbeConfigEntry 5 }
+
+emsProbeConfigProbeLowHumidityThresh OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Probe low humidity threshold.
+
+ Values are represented in whole number percentage."
+ ::= { emsProbeConfigEntry 6 }
+
+emsProbeConfigProbeMaxTempThresh OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Probe maximum temperature threshold.
+
+ Values are represented in whole number degrees.
+ Units are displayed in the scale shown in
+ the emsStatusSysTempUnits OID (Celsius or Fahrenheit)."
+ ::= { emsProbeConfigEntry 7 }
+
+emsProbeConfigProbeMinTempThresh OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Probe minimum temperature threshold.
+
+ Values are represented in whole number degrees.
+ Units are displayed in the scale shown in
+ the emsStatusSysTempUnits OID (Celsius or Fahrenheit)."
+ ::= { emsProbeConfigEntry 8 }
+
+emsProbeConfigProbeDeltaTemp OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Probe delta temperature.
+
+ Values are represented in whole number degrees.
+ Units are displayed in the scale shown in
+ the emsStatusSysTempUnits OID (Celsius or Fahrenheit)."
+ ::= { emsProbeConfigEntry 9 }
+
+emsProbeConfigProbeMaxHumidityThresh OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Probe maximum humidity threshold.
+
+ Values are represented in whole number percentage."
+ ::= { emsProbeConfigEntry 10 }
+
+emsProbeConfigProbeMinHumidityThresh OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Probe minimum humidity threshold.
+
+ Values are represented in whole number percentage."
+ ::= { emsProbeConfigEntry 11 }
+
+emsProbeConfigProbeDeltaHumidity OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Probe delta humidity.
+
+ Values are represented in whole number percentage."
+ ::= { emsProbeConfigEntry 12 }
+
+emsProbeConfigProbeSTIncTempVariance OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Probe short-term increasing temperature variance used for rate of change alarms.
+
+ Values are represented in whole number degrees.
+ Units are displayed in the scale shown in
+ the emsStatusSysTempUnits OID (Celsius or Fahrenheit)."
+ ::= { emsProbeConfigEntry 13 }
+
+emsProbeConfigProbeSTIncTempTime OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Probe short-term increasing temperature time used for rate of change alarms.
+
+ Values are represented in whole number minutes."
+ ::= { emsProbeConfigEntry 14 }
+
+emsProbeConfigProbeSTDecTempVariance OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Probe short-term decreasing temperature variance used for rate of change alarms.
+
+ Values are represented in whole number degrees.
+ Units are displayed in the scale shown in
+ the emsStatusSysTempUnits OID (Celsius or Fahrenheit)."
+ ::= { emsProbeConfigEntry 15 }
+
+emsProbeConfigProbeSTDecTempTime OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Probe short-term decreasing temperature time used for rate of change alarms.
+
+ Values are represented in whole number minutes."
+ ::= { emsProbeConfigEntry 16 }
+
+emsProbeConfigProbeLTIncTempVariance OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Probe long-term increasing temperature variance used for rate of change alarms.
+
+ Values are represented in whole number degrees.
+ Units are displayed in the scale shown in
+ the emsStatusSysTempUnits OID (Celsius or Fahrenheit)."
+ ::= { emsProbeConfigEntry 17 }
+
+emsProbeConfigProbeLTIncTempTime OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Probe long-term increasing temperature time used for rate of change alarms.
+
+ Values are represented in whole number hours."
+ ::= { emsProbeConfigEntry 18 }
+
+emsProbeConfigProbeLTDecTempVariance OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Probe long-term decreasing temperature variance used for rate of change alarms.
+
+ Values are represented in whole number degrees.
+ Units are displayed in the scale shown in
+ the emsStatusSysTempUnits OID (Celsius or Fahrenheit)."
+ ::= { emsProbeConfigEntry 19 }
+
+emsProbeConfigProbeLTDecTempTime OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Probe long-term decreasing temperature time used for rate of change alarms.
+
+ Values are represented in whole number hours."
+ ::= { emsProbeConfigEntry 20 }
+
+
+-- EMS INPUT CONTACT CONFIG STATUS TABLE
+
+emsInputContactConfigTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF EMSInputContactConfigEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for configuration of individual input contacts. The number of
+ entries is contained in the emsStatusInputContactCount OID."
+ ::= { emsInputContactConfig 1 }
+
+emsInputContactConfigEntry OBJECT-TYPE
+ SYNTAX EMSInputContactConfigEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The input contacts to configure."
+ INDEX { emsInputContactConfigInputContactIndex }
+ ::= { emsInputContactConfigTable 1 }
+
+EMSInputContactConfigEntry ::=
+ SEQUENCE {
+ emsInputContactConfigInputContactIndex INTEGER,
+ emsInputContactConfigInputContactName DisplayString,
+ emsInputContactConfigInputContactNormalState INTEGER
+ }
+
+emsInputContactConfigInputContactIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the input contact entry."
+ ::= { emsInputContactConfigEntry 1 }
+
+emsInputContactConfigInputContactName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The name of the input contact."
+ ::= { emsInputContactConfigEntry 2 }
+
+emsInputContactConfigInputContactNormalState OBJECT-TYPE
+ SYNTAX INTEGER {
+ normallyClosedEMS (1),
+ normallyOpenEMS (2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this variable will return the normal state of the input contact. If
+ the normal state is closed, the normallyClosedEMS (1) value will be returned.
+ If the normal state is closed, the normallyOpenEMS (2) value will be
+ returned.
+
+ Setting this variable will change the normal state of the input contact"
+ ::= { emsInputContactConfigEntry 3 }
+
+-- EMS OUTPUT RELAY CONFIG STATUS TABLE
+
+emsOutputRelayConfigTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF EMSOutputRelayConfigEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for configuration of individual output relays. The number of
+ entries is contained in the emsStatusOutputRelayCount OID."
+ ::= { emsOutputRelayConfig 1 }
+
+emsOutputRelayConfigEntry OBJECT-TYPE
+ SYNTAX EMSOutputRelayConfigEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The output relays to configure."
+ INDEX { emsOutputRelayConfigOutputRelayIndex }
+ ::= { emsOutputRelayConfigTable 1 }
+
+EMSOutputRelayConfigEntry ::=
+ SEQUENCE {
+ emsOutputRelayConfigOutputRelayIndex INTEGER,
+ emsOutputRelayConfigOutputRelayName DisplayString,
+ emsOutputRelayConfigOutputRelayNormalState INTEGER
+ }
+
+emsOutputRelayConfigOutputRelayIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the output relay entry."
+ ::= { emsOutputRelayConfigEntry 1 }
+
+emsOutputRelayConfigOutputRelayName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The name of the output relay."
+ ::= { emsOutputRelayConfigEntry 2 }
+
+emsOutputRelayConfigOutputRelayNormalState OBJECT-TYPE
+ SYNTAX INTEGER {
+ normallyClosedEMS (1),
+ normallyOpenEMS (2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this variable will return the normal state of the output relay. If
+ the normal state is closed, the normallyClosedEMS (1) value will be returned.
+ If the normal state is closed, the normallyOpenEMS (2) value will be
+ returned.
+
+ Setting this variable will change the normal state of the output relay"
+ ::= { emsOutputRelayConfigEntry 3 }
+
+-- EMS OUTLET CONFIG TABLE
+
+emsOutletConfigTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF EMSOutletConfigEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for configuration of individual outlets. The number of
+ entries is contained in the emsStatusOutletCount OID."
+ ::= { emsOutletConfig 1 }
+
+emsOutletConfigEntry OBJECT-TYPE
+ SYNTAX EMSOutletConfigEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The outlets to configure."
+ INDEX { emsOutletConfigOutletIndex }
+ ::= { emsOutletConfigTable 1 }
+
+EMSOutletConfigEntry ::=
+ SEQUENCE {
+ emsOutletConfigOutletIndex INTEGER,
+ emsOutletConfigOutletName DisplayString,
+ emsOutletConfigOutletNormalState INTEGER
+ }
+
+emsOutletConfigOutletIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the outlet entry."
+ ::= { emsOutletConfigEntry 1 }
+
+emsOutletConfigOutletName OBJECT-TYPE
+ SYNTAX DisplayString ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The name of the outlet."
+ ::= { emsOutletConfigEntry 2 }
+
+emsOutletConfigOutletNormalState OBJECT-TYPE
+ SYNTAX INTEGER {
+ normallyOnEMS (1),
+ normallyOffEMS (2)
+ }
+
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this variable will return the normal state of the outlet. If
+ the normal state is on, the normallyOnEMS (1) value will be returned.
+ If the normal state is off, the normallyOffEMS (2) value will be
+ returned.
+
+ Setting this variable will change the normal state of the outlet"
+ ::= { emsOutletConfigEntry 3 }
+
+-- EMS SENSOR CONFIG TABLE
+
+emsSensorConfigTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF EMSSensorConfigEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for configuration of individual sensors. The number of
+ entries is contained in the emsStatusSensorCount OID."
+ ::= { emsSensorConfig 1 }
+
+emsSensorConfigEntry OBJECT-TYPE
+ SYNTAX EMSSensorConfigEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The sensors to configure."
+ INDEX { emsSensorConfigSensorIndex }
+ ::= { emsSensorConfigTable 1 }
+
+EMSSensorConfigEntry ::=
+ SEQUENCE {
+ emsSensorConfigSensorIndex INTEGER,
+ emsSensorConfigSensorSystemName DisplayString,
+ emsSensorConfigSensorUserName DisplayString,
+ emsSensorConfigSensorNormalState INTEGER,
+ emsSensorConfigSensorAlarmDelay INTEGER
+ }
+
+emsSensorConfigSensorIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the sensor entry."
+ ::= { emsSensorConfigEntry 1 }
+
+emsSensorConfigSensorSystemName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The system name of the sensor. This describes the hardware system
+ intent of this sensor."
+ ::= { emsSensorConfigEntry 2 }
+
+emsSensorConfigSensorUserName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The name of the sensor as given by the system user."
+ ::= { emsSensorConfigEntry 3 }
+
+emsSensorConfigSensorNormalState OBJECT-TYPE
+ SYNTAX INTEGER {
+ normallyClosedEMS (1),
+ normallyOpenEMS (2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this variable will return the normal state of the sensor. If
+ the normal state is closed, the normallyClosedEMS (1) value will be returned.
+ If the normal state is closed, the normallyOpenEMS (2) value will be
+ returned.
+
+ Setting this variable will change the normal state of the sensor. Note:
+ Only the AUX sensor in the EMS has a configurable Normal State"
+ ::= { emsSensorConfigEntry 4 }
+
+emsSensorConfigSensorAlarmDelay OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The delay (in seconds) after a sensor detects an alarm condition before the
+ condition is reported."
+ ::= { emsSensorConfigEntry 5 }
+
+-- EMS STATUS
+--- EMS MASTER status
+
+emsStatusEMSName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A character string identifying the
+ device. "
+ ::= { emsStatus 1 }
+
+emsStatusCommStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ noComm(1),
+ comm(2),
+ commLost(3)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The communication status between the agent
+ and the device.
+
+ noComm(1), Communication has never been established.
+ comm(2), Communication has been established.
+ commLost(3), Communication was established, but was lost."
+ ::= { emsStatus 2 }
+
+emsStatusProbeCount OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The total number of T/H probes (both local and remote) that
+ is supported by this device."
+ ::= { emsStatus 3 }
+
+emsStatusInputContactCount OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The total number of Input Contacts that
+ is supported by this device."
+ ::= { emsStatus 4 }
+
+emsStatusOutputRelayCount OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The total number of Output Relays that
+ is supported by this device."
+ ::= { emsStatus 5 }
+
+emsStatusOutletCount OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The total number of AC Outlets that
+ is supported by this device."
+ ::= { emsStatus 6 }
+
+emsStatusSensorCount OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The total number of Sensors that
+ is supported by this device."
+ ::= { emsStatus 7 }
+
+emsStatusAlinkAruDeviceCount OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The total number of remote Aru's supported by this device."
+ ::= { emsStatus 8 }
+
+emsStatusAlinkProbeDeviceCount OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The total number of remote T/H probes supported by this device."
+ ::= { emsStatus 9 }
+
+emsStatusAlarmDeviceCount OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of alarm devices supported by this device."
+ ::= { emsStatus 10 }
+
+emsStatusSysTempUnits OBJECT-TYPE
+ SYNTAX INTEGER {
+ celsius(1),
+ fahrenheit(2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The temperature scale used to display the temperature
+ in the system, Celsius(1) or Fahrenheit(2).
+ This setting is based on the system preferences
+ configuration in the agent."
+ ::= { emsStatus 11 }
+
+emsStatusCheckLogLight OBJECT-TYPE
+ SYNTAX INTEGER {
+ lightOff (1),
+ lightOn (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The status of the check-log light on the device.
+ For the EMU2, this will always indicate lightOff(1).
+
+ lightOff (1) indicates the light is off (no new log entries).
+ lightOn (2) indicates the light is on (new log entries present)."
+
+ ::= { emsStatus 12 }
+
+emsStatusHardwareStatus OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The status of the EMS hardware. This integer should be interpreted
+ as a bit map, with each bit representing the presence or absence of
+ a specific hardware error condition.
+
+ 0 indicates there are no error conditions detected in the EMS hardware.
+ 1 indicates a Current Limit error condition related to the Alink port.
+ 2 indicates incorrect hardware is plugged into an EMS port.
+ 3 indicates that both of these error conditions are present."
+
+ ::= { emsStatus 13 }
+
+-- EMS PROBE STATUS TABLE
+
+emsProbeStatusTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF EMSProbeStatusEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for access of individual probes. The number of
+ entries is contained in the emsStatusProbeCount OID."
+ ::= { emsProbeStatus 1 }
+
+emsProbeStatusEntry OBJECT-TYPE
+ SYNTAX EMSProbeStatusEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The probes to access."
+ INDEX { emsProbeStatusProbeIndex }
+ ::= { emsProbeStatusTable 1 }
+
+EMSProbeStatusEntry ::=
+ SEQUENCE {
+ emsProbeStatusProbeIndex INTEGER,
+ emsProbeStatusProbeName DisplayString,
+ emsProbeStatusProbeTemperature INTEGER,
+ emsProbeStatusProbeHighTempThresh INTEGER,
+ emsProbeStatusProbeLowTempThresh INTEGER,
+ emsProbeStatusProbeHumidity INTEGER,
+ emsProbeStatusProbeHighHumidityThresh INTEGER,
+ emsProbeStatusProbeLowHumidityThresh INTEGER,
+ emsProbeStatusProbeSerialNumber DisplayString,
+ emsProbeStatusProbeCommStatus INTEGER,
+ emsProbeStatusProbeAlarmStatus INTEGER,
+ emsProbeStatusProbeMaxTempThresh INTEGER,
+ emsProbeStatusProbeMinTempThresh INTEGER,
+ emsProbeStatusProbeMaxHumidityThresh INTEGER,
+ emsProbeStatusProbeMinHumidityThresh INTEGER
+ }
+
+emsProbeStatusProbeIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the probe entry."
+ ::= { emsProbeStatusEntry 1 }
+
+emsProbeStatusProbeName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The name of the probe."
+ ::= { emsProbeStatusEntry 2 }
+
+emsProbeStatusProbeTemperature OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Probe temperature reading.
+
+ Values are represented in whole number degrees.
+ Units are displayed in the scale shown in
+ the emsStatusSysTempUnits OID (Celsius or Fahrenheit)."
+ ::= { emsProbeStatusEntry 3 }
+
+emsProbeStatusProbeHighTempThresh OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Probe high temperature threshold.
+
+ Values are represented in whole number degrees.
+ Units are displayed in the scale shown in
+ the emsStatusSysTempUnits OID (Celsius or Fahrenheit)."
+ ::= { emsProbeStatusEntry 4 }
+
+emsProbeStatusProbeLowTempThresh OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Probe low temperature threshold.
+
+ Values are represented in whole number degrees.
+ Units are displayed in the scale shown in
+ the emsStatusSysTempUnits OID (Celsius or Fahrenheit)."
+ ::= { emsProbeStatusEntry 5 }
+
+emsProbeStatusProbeHumidity OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Probe humidity reading.
+
+ Values are represented in whole number percentage."
+ ::= { emsProbeStatusEntry 6 }
+
+emsProbeStatusProbeHighHumidityThresh OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Probe high humidity threshold.
+
+ Values are represented in whole number percentage."
+ ::= { emsProbeStatusEntry 7 }
+
+emsProbeStatusProbeLowHumidityThresh OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Probe low humidity threshold.
+
+ Values are represented in whole number percentage."
+ ::= { emsProbeStatusEntry 8 }
+
+emsProbeStatusProbeSerialNumber OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A label indicating the type (Local[L] or Remote[R]) and Number
+ of the probe. For example, the first local probe would be L1 and
+ the third remote probe would be R3."
+ ::= { emsProbeStatusEntry 9 }
+
+emsProbeStatusProbeCommStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ commsNeverDiscovered(1),
+ commsEstablished(2),
+ commsLost(3)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ " The state of communications to the probe.
+ commNeverDiscovered(1) indicates there has never been communications with this device.
+ commsEstablished(2) indicates communication is normal and active with this device.
+ commsLost(3) indicates communication had been established, but is no longer."
+ ::= { emsProbeStatusEntry 10 }
+
+emsProbeStatusProbeAlarmStatus OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The alarm status of the probe. This integer should be interpreted
+ as a bit map, with each bit representing the presence or absence of
+ the specific alarm conditions listed below. The bit will be '1' if
+ the condition is present, and '0' if the condition is not present.
+
+ Bit Hex. Value Description
+ 1 0x0001 Maximum temperature exceeded.
+ 2 0x0002 High temperature exceeded.
+ 3 0x0004 Low temperature exceeded.
+ 4 0x0008 Minimum temperature exceeded.
+ 5 0x0010 Short-term increasing temperature rate exceeded.
+ 6 0x0020 Short-term decreasing temperature rate exceeded.
+ 7 0x0040 Long-term increasing temperature rate exceeded.
+ 8 0x0080 Long-term decreasing temperature rate exceeded.
+ 9 0x0100 Maximum humidity exceeded.
+ 10 0x0200 High humidity exceeded.
+ 11 0x0400 Low humidity exceeded.
+ 12 0x0800 Minimum humidity exceeded."
+ ::= { emsProbeStatusEntry 11 }
+
+emsProbeStatusProbeMaxTempThresh OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Probe maximum temperature threshold.
+
+ Values are represented in whole number degrees.
+ Units are displayed in the scale shown in
+ the emsStatusSysTempUnits OID (Celsius or Fahrenheit)."
+ ::= { emsProbeStatusEntry 12 }
+
+emsProbeStatusProbeMinTempThresh OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Probe minimum temperature threshold.
+
+ Values are represented in whole number degrees.
+ Units are displayed in the scale shown in
+ the emsStatusSysTempUnits OID (Celsius or Fahrenheit)."
+ ::= { emsProbeStatusEntry 13 }
+
+emsProbeStatusProbeMaxHumidityThresh OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Probe maximum humidity threshold.
+
+ Values are represented in whole number percentage."
+ ::= { emsProbeStatusEntry 14 }
+
+emsProbeStatusProbeMinHumidityThresh OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Probe minimum humidity threshold.
+
+ Values are represented in whole number percentage."
+ ::= { emsProbeStatusEntry 15 }
+
+
+-- EMS INPUT CONTACT STATUS TABLE
+
+emsInputContactStatusTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF EMSInputContactStatusEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for access of individual input contacts. The number of
+ entries is contained in the emsStatusInputContactCount OID."
+ ::= { emsInputContactStatus 1 }
+
+emsInputContactStatusEntry OBJECT-TYPE
+ SYNTAX EMSInputContactStatusEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The input contacts to access."
+ INDEX { emsInputContactStatusInputContactIndex }
+ ::= { emsInputContactStatusTable 1 }
+
+EMSInputContactStatusEntry ::=
+ SEQUENCE {
+ emsInputContactStatusInputContactIndex INTEGER,
+ emsInputContactStatusInputContactName DisplayString,
+ emsInputContactStatusInputContactState INTEGER,
+ emsInputContactStatusInputContactNormalState INTEGER
+ }
+
+emsInputContactStatusInputContactIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the input contact entry."
+ ::= { emsInputContactStatusEntry 1 }
+
+emsInputContactStatusInputContactName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The name of the input contact."
+ ::= { emsInputContactStatusEntry 2 }
+
+emsInputContactStatusInputContactState OBJECT-TYPE
+ SYNTAX INTEGER {
+ contactClosedEMS (1),
+ contactOpenEMS (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this variable will return the state of the input contact. If
+ the input contact is closed, the contactClosedEMS (1) value will be returned.
+ If the input contact state is open, the contactOpenEMS (2) value will be
+ returned. "
+
+ ::= { emsInputContactStatusEntry 3 }
+
+emsInputContactStatusInputContactNormalState OBJECT-TYPE
+ SYNTAX INTEGER {
+ normallyClosedEMS (1),
+ normallyOpenEMS (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this variable will return the normal state of the input contact. If
+ the normal state is closed, the normallyClosedEMS (1) value will be returned.
+ If the normal state is open, the normallyOpenEMS (2) value will be
+ returned. "
+
+ ::= { emsInputContactStatusEntry 4 }
+
+
+-- EMS OUTPUT RELAY STATUS TABLE
+
+emsOutputRelayStatusTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF EMSOutputRelayStatusEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for access of individual output relays. The number of
+ entries is contained in the emsStatusOutputRelayCount OID."
+ ::= { emsOutputRelayStatus 1 }
+
+emsOutputRelayStatusEntry OBJECT-TYPE
+ SYNTAX EMSOutputRelayStatusEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The output relays to access."
+ INDEX { emsOutputRelayStatusOutputRelayIndex }
+ ::= { emsOutputRelayStatusTable 1 }
+
+EMSOutputRelayStatusEntry ::=
+ SEQUENCE {
+ emsOutputRelayStatusOutputRelayIndex INTEGER,
+ emsOutputRelayStatusOutputRelayName DisplayString,
+ emsOutputRelayStatusOutputRelayState INTEGER,
+ emsOutputRelayStatusOutputRelayNormalState INTEGER
+ }
+
+emsOutputRelayStatusOutputRelayIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the output relay entry."
+ ::= { emsOutputRelayStatusEntry 1 }
+
+emsOutputRelayStatusOutputRelayName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The name of the output relay."
+ ::= { emsOutputRelayStatusEntry 2 }
+
+emsOutputRelayStatusOutputRelayState OBJECT-TYPE
+ SYNTAX INTEGER {
+ relayClosedEMS (1),
+ relayOpenEMS (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this variable will return the state of the output relay. If
+ the output relay is closed, the relayClosedEMS (1) value will be returned.
+ If the output relay is open, the relayOpenEMS (2) value will be
+ returned. "
+
+ ::= { emsOutputRelayStatusEntry 3 }
+
+emsOutputRelayStatusOutputRelayNormalState OBJECT-TYPE
+ SYNTAX INTEGER {
+ normallyClosedEMS (1),
+ normallyOpenEMS (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this variable will return the normal state of the output relay. If
+ the normal state is closed, the normallyClosedEMS (1) value will be returned.
+ If the normal state is open, the normallyOpenEMS (2) value will be
+ returned. "
+
+ ::= { emsOutputRelayStatusEntry 4 }
+
+-- EMS OUTLET STATUS TABLE
+
+emsOutletStatusTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF EMSOutletStatusEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for access of individual outlets. The number of
+ entries is contained in the emsStatusOutletCount OID."
+ ::= { emsOutletStatus 1 }
+
+emsOutletStatusEntry OBJECT-TYPE
+ SYNTAX EMSOutletStatusEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The outlets to access."
+ INDEX { emsOutletStatusOutletIndex }
+ ::= { emsOutletStatusTable 1 }
+
+EMSOutletStatusEntry ::=
+ SEQUENCE {
+ emsOutletStatusOutletIndex INTEGER,
+ emsOutletStatusOutletName DisplayString,
+ emsOutletStatusOutletState INTEGER,
+ emsOutletStatusOutletNormalState INTEGER
+ }
+
+emsOutletStatusOutletIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the outlet entry."
+ ::= { emsOutletStatusEntry 1 }
+
+emsOutletStatusOutletName OBJECT-TYPE
+ SYNTAX DisplayString ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The name of the outlet."
+ ::= { emsOutletStatusEntry 2 }
+
+emsOutletStatusOutletState OBJECT-TYPE
+ SYNTAX INTEGER {
+ outletOnEMS (1),
+ outletOffEMS (2)
+ }
+
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this variable will return the state of the outlet. If
+ the outlet is on, the outletOnEMS (1) value will be returned.
+ If the outlet is off, the outletOffEMS (2) value will be
+ returned. "
+
+ ::= { emsOutletStatusEntry 3 }
+
+emsOutletStatusOutletNormalState OBJECT-TYPE
+ SYNTAX INTEGER {
+ normallyOnEMS (1),
+ normallyOffEMS (2)
+ }
+
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this variable will return the normal state of the outlet. If
+ the normal state is on, the normallyOnEMS (1) value will be returned.
+ If the normal state is off, the normallyOffEMS (2) value will be
+ returned. "
+
+ ::= { emsOutletStatusEntry 4 }
+
+-- EMS ALARM DEVICE STATUS TABLE
+
+emsAlarmDeviceStatusTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF EMSAlarmDeviceStatusEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for access of individual alarm devices. The number of
+ entries is contained in the emsStatusAlarmDeviceCount OID."
+ ::= { emsAlarmDeviceStatus 1 }
+
+emsAlarmDeviceStatusEntry OBJECT-TYPE
+ SYNTAX EMSAlarmDeviceStatusEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The alarm devices to access."
+ INDEX { emsAlarmDeviceStatusDeviceIndex }
+ ::= { emsAlarmDeviceStatusTable 1 }
+
+EMSAlarmDeviceStatusEntry ::=
+ SEQUENCE {
+ emsAlarmDeviceStatusDeviceIndex INTEGER,
+ emsAlarmDeviceStatusDeviceName DisplayString,
+ emsAlarmDeviceStatusDeviceState INTEGER
+ }
+
+emsAlarmDeviceStatusDeviceIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the alarm device entry."
+ ::= { emsAlarmDeviceStatusEntry 1 }
+
+emsAlarmDeviceStatusDeviceName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The name of the alarm device.
+ This OID is provided for informational purposes only."
+ ::= { emsAlarmDeviceStatusEntry 2 }
+
+emsAlarmDeviceStatusDeviceState OBJECT-TYPE
+ SYNTAX INTEGER {
+ alarmDeviceOnEMS (1),
+ alarmDeviceOffEMS (2),
+ alarmDeviceNotInstalledEMS (3)
+ }
+
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this variable will return the device state. If
+ the device is active, the alarmDeviceOnEMS (1) value will be returned.
+ If the device is inactive, the alarmDeviceOffEMS (2) value will be
+ returned. If the device is not installed, the
+ alarmDeviceNotInstalledEMS (3) value will be returned."
+
+ ::= { emsAlarmDeviceStatusEntry 3 }
+
+
+-- EMS SENSOR STATUS TABLE
+
+emsSensorStatusTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF EMSSensorStatusEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for access of individual sensors. The number of
+ entries is contained in the emsStatusSensorCount OID."
+ ::= { emsSensorStatus 1 }
+
+emsSensorStatusEntry OBJECT-TYPE
+ SYNTAX EMSSensorStatusEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The sensors to access."
+ INDEX { emsSensorStatusSensorIndex }
+ ::= { emsSensorStatusTable 1 }
+
+EMSSensorStatusEntry ::=
+ SEQUENCE {
+ emsSensorStatusSensorIndex INTEGER,
+ emsSensorStatusSensorSystemName DisplayString,
+ emsSensorStatusSensorName DisplayString,
+ emsSensorStatusSensorState INTEGER,
+ emsSensorStatusSensorNormalState INTEGER,
+ emsSensorStatusSensorAlarmDelay INTEGER
+ }
+
+emsSensorStatusSensorIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the sensor entry."
+ ::= { emsSensorStatusEntry 1 }
+
+emsSensorStatusSensorSystemName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The system name of the sensor. This describes the hardware system
+ intent of this sensor."
+ ::= { emsSensorStatusEntry 2 }
+
+emsSensorStatusSensorName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The name of the sensor as given by the system user."
+ ::= { emsSensorStatusEntry 3 }
+
+emsSensorStatusSensorState OBJECT-TYPE
+ SYNTAX INTEGER {
+ sensorFaultedEMS (1),
+ sensorOKEMS (2),
+ sensorNotInstalledEMS (3)
+ }
+
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this variable will return the sensor state. If the sensor is faulted,
+ the sensorFaultedEMS (1) value will be returned.
+ If the sensor is not faulted, the sensorOKEMS (2) value will be
+ returned. If the sensor is not installed, the sensorNotInstalledEMS (3)
+ value will be returned."
+ ::= { emsSensorStatusEntry 4 }
+
+emsSensorStatusSensorNormalState OBJECT-TYPE
+ SYNTAX INTEGER {
+ normallyClosedEMS (1),
+ normallyOpenEMS (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Getting this variable will return the normal state of the sensor. If
+ the normal state is closed, the normallyClosedEMS (1) value will be returned.
+ If the normal state is closed, the normallyOpenEMS (2) value will be
+ returned."
+ ::= { emsSensorStatusEntry 5 }
+
+emsSensorStatusSensorAlarmDelay OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The delay (in seconds) after a sensor detects an alarm condition before the
+ condition is reported."
+ ::= { emsSensorStatusEntry 6 }
+
+
+
+-- airFM AIR CONDITIONER IDENT
+
+airFMIdentName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A character string identifying the
+ device. "
+ ::= { airFMIdent 1 }
+
+airFMIdentTableSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of entries in the airFMIdentTable. "
+ ::= { airFMIdent 2 }
+
+airFMIdentTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF AirFMIdentTableEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for getting identification information
+ from each module in the system. "
+ ::= { airFMIdent 3 }
+
+airFMIdentTableEntry OBJECT-TYPE
+ SYNTAX AirFMIdentTableEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The module to get information from."
+ INDEX { airFMIdentModuleIndex }
+ ::= { airFMIdentTable 1 }
+
+AirFMIdentTableEntry ::=
+ SEQUENCE {
+ airFMIdentModuleIndex INTEGER,
+ airFMIdentModuleModelNumber DisplayString,
+ airFMIdentModuleDateOfMfg DisplayString,
+ airFMIdentModuleSerialNumber DisplayString,
+ airFMIdentModuleFirmwareRev DisplayString,
+ airFMIdentModuleHardwareRev DisplayString
+ }
+
+airFMIdentModuleIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index of the module information."
+ ::= { airFMIdentTableEntry 1 }
+
+airFMIdentModuleModelNumber OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A character string identifying the
+ model number. "
+ ::= { airFMIdentTableEntry 2 }
+
+airFMIdentModuleDateOfMfg OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A character string identifying the
+ manufacture date. "
+ ::= { airFMIdentTableEntry 3 }
+
+airFMIdentModuleSerialNumber OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A character string identifying the
+ unit serial number. "
+ ::= { airFMIdentTableEntry 4 }
+
+airFMIdentModuleFirmwareRev OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A character string identifying the
+ firmware revision. "
+ ::= { airFMIdentTableEntry 5 }
+
+airFMIdentModuleHardwareRev OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A character string identifying the
+ hardware revision. "
+ ::= { airFMIdentTableEntry 6 }
+
+-- airFM AIR CONDITIONER STATUS
+
+airFMStatusSystemOn OBJECT-TYPE
+ SYNTAX INTEGER {
+ statusOn (1),
+ statusOff (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The operating state of the system. "
+ ::= { airFMStatus 1 }
+
+airFMStatusSystemAverageRetTempC OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The system average return air
+ temperature in tenths of degrees Celsius. "
+ ::= { airFMStatus 2 }
+
+airFMStatusSystemAverageRetTempF OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The system average return air
+ temperature in tenths of degrees Fahrenheit. "
+ ::= { airFMStatus 3 }
+
+airFMStatusSystemAverageRetHum OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The system average return air
+ humidity. "
+ ::= { airFMStatus 4 }
+
+airFMStatusSystemActionTempC OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The system action air
+ temperature in tenths of degrees Celsius. "
+ ::= { airFMStatus 5 }
+
+airFMStatusSystemActionTempF OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The system action air
+ temperature in tenths of degrees Fahrenheit. "
+ ::= { airFMStatus 6 }
+
+airFMStatusSystemActionHum OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The system action air humidity. "
+ ::= { airFMStatus 7 }
+
+airFMStatusSystemRemoteHighTempC OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The system remote high air
+ temperature in tenths of degrees Celsius. "
+ ::= { airFMStatus 8 }
+
+airFMStatusSystemRemoteHighTempF OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The system remote high air
+ temperature in tenths of degrees Fahrenheit. "
+ ::= { airFMStatus 9 }
+
+airFMStatusSystemRemoteAvgTempC OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The system remote average air
+ temperature in tenths of degrees Celsius. "
+ ::= { airFMStatus 10 }
+
+airFMStatusSystemRemoteAvgTempF OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The system remote average air
+ temperature in tenths of degrees Fahrenheit. "
+ ::= { airFMStatus 11 }
+
+airFMStatusSystemRemoteAvgHum OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The system remote average air
+ humidity. "
+ ::= { airFMStatus 12 }
+
+airFMStatusSystemRemoteLowTempC OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The system remote low air
+ temperature in tenths of degrees Celsius. "
+ ::= { airFMStatus 13 }
+
+airFMStatusSystemRemoteLowTempF OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The system remote low air
+ temperature in tenths of degrees Fahrenheit. "
+ ::= { airFMStatus 14 }
+
+airFMStatusSystemCoolingEnabled OBJECT-TYPE
+ SYNTAX INTEGER {
+ enabledYes (1),
+ enabledNo (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The state of the system cooling
+ function enable. "
+ ::= { airFMStatus 15 }
+
+airFMStatusSystemReheatingEnabled OBJECT-TYPE
+ SYNTAX INTEGER {
+ enabledYes (1),
+ enabledNo (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The state of the system reheating
+ function enable. "
+ ::= { airFMStatus 16 }
+
+airFMStatusSystemHumidifyEnabled OBJECT-TYPE
+ SYNTAX INTEGER {
+ enabledYes (1),
+ enabledNo (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The state of the system humidify
+ function enable. "
+ ::= { airFMStatus 17 }
+
+airFMStatusSystemDehumidifyEnabled OBJECT-TYPE
+ SYNTAX INTEGER {
+ enabledYes (1),
+ enabledNo (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The state of the system dehumidify
+ function enable. "
+ ::= { airFMStatus 18 }
+
+airFMStatusModuleTableSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of entries in the airFMStatusModuleTable. "
+ ::= { airFMStatus 19 }
+
+airFMStatusModuleTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF AirFMStatusModuleEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for getting information from each module
+ in the system. "
+ ::= { airFMStatus 20 }
+
+airFMStatusModuleEntry OBJECT-TYPE
+ SYNTAX AirFMStatusModuleEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The module to get status from."
+ INDEX { airFMStatusModuleIndex }
+ ::= { airFMStatusModuleTable 1 }
+
+AirFMStatusModuleEntry ::=
+ SEQUENCE {
+ airFMStatusModuleIndex INTEGER,
+ airFMStatusModuleOutputCapacity INTEGER,
+ airFMStatusModuleSupplyTempC INTEGER,
+ airFMStatusModuleSupplyTempF INTEGER,
+ airFMStatusModuleSupplyHum INTEGER,
+ airFMStatusModuleReturnTempC INTEGER,
+ airFMStatusModuleReturnTempF INTEGER,
+ airFMStatusModuleReturnHum INTEGER
+ }
+
+airFMStatusModuleIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index of the module information."
+ ::= { airFMStatusModuleEntry 1 }
+
+airFMStatusModuleOutputCapacity OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The module output capacity in kilowatts."
+ ::= { airFMStatusModuleEntry 2 }
+
+airFMStatusModuleSupplyTempC OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The module supply air temperature in
+ tenths of degrees Celsius. "
+ ::= { airFMStatusModuleEntry 3 }
+
+airFMStatusModuleSupplyTempF OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The module supply air temperature in
+ tenths of degrees Fahrenheit. "
+ ::= { airFMStatusModuleEntry 4 }
+
+airFMStatusModuleSupplyHum OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The module supply air humidity. "
+ ::= { airFMStatusModuleEntry 5 }
+
+airFMStatusModuleReturnTempC OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The module return air temperature in
+ tenths of degrees Celsius. "
+ ::= { airFMStatusModuleEntry 6 }
+
+airFMStatusModuleReturnTempF OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The module return air temperature in
+ tenths of degrees Fahrenheit. "
+ ::= { airFMStatusModuleEntry 7 }
+
+airFMStatusModuleReturnHum OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The module return air humidity. "
+ ::= { airFMStatusModuleEntry 8 }
+
+-- airFM AIR CONDITIONER GROUP DATA
+
+airFMGroupSysStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ statusOnLine (1),
+ statusIdle (2),
+ statusLoadShare (3),
+ statusOffLine (4),
+ statusFailed (5)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The status of this system within the group. "
+ ::= { airFMGroup 1 }
+
+airFMGroupSysRuntime OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of hours the system has been running. "
+ ::= { airFMGroup 2 }
+
+airFMGroupSysRole OBJECT-TYPE
+ SYNTAX INTEGER {
+ rolePrimary (1),
+ roleBackup (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The role of this system within the group. "
+ ::= { airFMGroup 3 }
+
+-- airPA Portable Air Conditioner Ident
+
+airPAIdentName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A character string identifying the device name. "
+ ::= { airPAIdent 1 }
+
+airPAModelNumber OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A character string identifying the device model number. "
+ ::= { airPAIdent 2 }
+
+airPADateOfManufacture OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A character string identifying when the device was produced. "
+ ::= { airPAIdent 3 }
+
+airPASerialNumber OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A character string identifying the device serial number. "
+ ::= { airPAIdent 4 }
+
+airPAFirmwareRevision OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A character string identifying the device firmware revision. "
+ ::= { airPAIdent 5 }
+
+airPAHardwareRevision OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A character string identifying the device hardware revision. "
+ ::= { airPAIdent 6 }
+
+-- airPA Portable Air Conditioner Status
+
+airPASystemPower OBJECT-TYPE
+ SYNTAX INTEGER {
+ powerON (1),
+ powerOFF (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The status of the unit's system power setting.
+
+ ON(1) The system power is turned on.
+ OFF(2) The system power is turned off. "
+ ::= { airPAStatus 1 }
+
+airPAOperatingMode OBJECT-TYPE
+ SYNTAX INTEGER {
+ modeOFF (1),
+ modeVENTING (2),
+ modeCOOLING (3)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The current operating mode of the unit.
+
+ OFF(1) The system is off.
+ VENTING(2) The system's venting function is active.
+ COOLING(3) The system's cooling function is active. "
+ ::= { airPAStatus 2 }
+
+airPASetpointTempF OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The temperature setpoint in Fahrenheit to which the unit is controlling. "
+ ::= { airPAStatus 3 }
+
+airPASetpointTempC OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The temperature setpoint in Celsius to which the unity is controlling. "
+ ::= { airPAStatus 4 }
+
+airPABlowerSpeed OBJECT-TYPE
+ SYNTAX INTEGER {
+ speedLOW (1),
+ speedHIGH (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The unit's blower speed setting.
+
+ LOW(1) The blower speed is low.
+ HIGH(2) The blower speed is high. "
+ ::= { airPAStatus 5 }
+
+airPACompressor OBJECT-TYPE
+ SYNTAX INTEGER {
+ statusON (1),
+ statusOFF (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The unit's compressor status.
+
+ ON(1) The compressor is turned on.
+ OFF(2) The compressor is turned off. "
+ ::= { airPAStatus 6 }
+
+airPACondenserFan OBJECT-TYPE
+ SYNTAX INTEGER {
+ statusON (1),
+ statusOFF (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The unit's condenser fan status.
+
+ ON(1) The condenser fan is turned on.
+ OFF(2) The condenser fan is turned off. "
+ ::= { airPAStatus 7 }
+
+airPACondensatePump OBJECT-TYPE
+ SYNTAX INTEGER {
+ statusON (1),
+ statusOFF (2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The unit's condensate pump status.
+
+ ON(1) The condensate pump is turned on.
+ OFF(2) The condensate pump is turned off. "
+ ::= { airPAStatus 8 }
+
+airPASupplyTempF OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The supply temperature in degrees Fahrenheit. "
+ ::= { airPAStatus 9 }
+
+airPASupplyTempC OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The supply temperature in degrees Celsius. "
+ ::= { airPAStatus 10 }
+
+airPAReturnTempF OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The return temperature in degrees Fahrenheit. "
+ ::= { airPAStatus 11 }
+
+airPAReturnTempC OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The return temperature in degrees Celsius. "
+ ::= { airPAStatus 12 }
+
+airPARemoteTempF OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The remote temperature in degrees Fahrenheit. "
+ ::= { airPAStatus 13 }
+
+airPARemoteTempC OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The remote temperature in degrees Celsius. "
+ ::= { airPAStatus 14 }
+
+airPARemoteHumidity OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The remote humidity. "
+ ::= { airPAStatus 15 }
+
+-- RACK AIR REMOVAL UNIT IDENT
+
+rARUIdentTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF IdentRARUEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for query of the individual devices.
+ The number of entries is contained in the
+ rARUStatusAruDeviceCount OID."
+ ::= { rARUIdent 1 }
+
+rARUIdentEntry OBJECT-TYPE
+ SYNTAX IdentRARUEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The device to query."
+ INDEX { rARUIdentIndex}
+ ::= { rARUIdentTable 1 }
+
+IdentRARUEntry ::=
+ SEQUENCE {
+ rARUIdentIndex INTEGER,
+ rARUIdentName DisplayString
+ }
+
+rARUIdentIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the device entry."
+ ::= { rARUIdentEntry 1 }
+
+rARUIdentName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A character string identifying the
+ device. "
+ ::= { rARUIdentEntry 2 }
+
+
+-- RACK AIR REMOVAL UNIT CONFIGURATION
+
+rARUConfigTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ConfigRARUEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for configuration of individual ARUs. The number of
+ entries is contained in the rARUStatusAruDeviceCount OID."
+ ::= { rARUConfig 1 }
+
+rARUConfigEntry OBJECT-TYPE
+ SYNTAX ConfigRARUEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The ARUs to configure."
+ INDEX { rARUConfigAruIndex }
+ ::= { rARUConfigTable 1 }
+
+ConfigRARUEntry ::=
+ SEQUENCE {
+ rARUConfigAruIndex INTEGER,
+ rARUConfigAruName DisplayString,
+ rARUConfigAruRemoteSetpoint INTEGER,
+ rARUConfigAruTempOvrdEnableDisable INTEGER,
+ rARUConfigAruTempOvrdSetpoint INTEGER
+ }
+
+rARUConfigAruIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the device entry."
+ ::= { rARUConfigEntry 1 }
+
+rARUConfigAruName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The name of the ARU."
+ ::= { rARUConfigEntry 2 }
+
+rARUConfigAruRemoteSetpoint OBJECT-TYPE
+ SYNTAX INTEGER {
+ aruOff (1),
+ aru85F-29C (2),
+ aru90F-32C (3),
+ aru95F-35C (4),
+ aru100F-38C (5),
+ aru7kW (6),
+ aru5kW (7),
+ aru3kW (8),
+ aru2kW (9)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "This OID is the Remote setpoint of the ARU.
+ NOTE: -1 will be returned if the ARU is not communicating."
+
+ ::= { rARUConfigEntry 3 }
+
+rARUConfigAruTempOvrdEnableDisable OBJECT-TYPE
+ SYNTAX INTEGER {
+ disabled(1),
+ enabled(2)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "This OID is used to enable/disable the remote temperature override setting of the ARU.
+
+ If this OID is set to 1, the remote setting for temperature override is disabled.
+ If this OID is set to 2, the remote setting for temperature override is enabled."
+ ::= { rARUConfigEntry 4 }
+
+rARUConfigAruTempOvrdSetpoint OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "This OID is the Temperature Override setpoint of the ARU.
+ NOTE: -1 will be returned if the ARU is not communicating."
+
+ ::= { rARUConfigEntry 5 }
+
+-- RACK AIR REMOVAL UNIT STATUS
+
+rARUStatusAruDeviceCount OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The total number of ARUs accessible from this IP."
+ ::= { rARUStatus 1 }
+
+rARUStatusSysTempUnits OBJECT-TYPE
+ SYNTAX INTEGER {
+ celsius(1),
+ fahrenheit(2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The temperature scale used to display the temperature
+ in the system, Celsius(1) or Fahrenheit(2).
+ This setting is based on the system preferences
+ configuration in the agent."
+ ::= { rARUStatus 2 }
+
+rARUStatusTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF StatusRARUEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "Allows for access of individual ARUs. The number of
+ entries is contained in the rARUStatusAruDeviceCount OID."
+ ::= { rARUStatus 3 }
+
+rARUStatusEntry OBJECT-TYPE
+ SYNTAX StatusRARUEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The ARUs to access."
+ INDEX { rARUStatusAruIndex }
+ ::= { rARUStatusTable 1 }
+
+StatusRARUEntry ::=
+ SEQUENCE {
+ rARUStatusAruIndex INTEGER,
+ rARUStatusAruName DisplayString,
+ rARUStatusAruRemoteSetpoint INTEGER,
+ rARUStatusAruManualSetpoint INTEGER,
+ rARUStatusAruTemp1 INTEGER,
+ rARUStatusAruTemp2 INTEGER,
+ rARUStatusAruTemp3 INTEGER,
+ rARUStatusAruTempOvrdEnableDisable INTEGER,
+ rARUStatusAruTempOvrdSetpoint INTEGER,
+ rARUStatusAruAlarmState DisplayString,
+ rARUStatusAruCommStatus INTEGER
+ }
+
+rARUStatusAruIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to the ARU entry."
+ ::= { rARUStatusEntry 1 }
+
+rARUStatusAruName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The name of the ARU."
+ ::= { rARUStatusEntry 2 }
+
+rARUStatusAruRemoteSetpoint OBJECT-TYPE
+ SYNTAX INTEGER {
+ aruOff (1),
+ aru85F-29C (2),
+ aru90F-32C (3),
+ aru95F-35C (4),
+ aru100F-38C (5),
+ aru7kW (6),
+ aru5kW (7),
+ aru3kW (8),
+ aru2kW (9)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "ARU remote setpoint temperature setting.
+
+ NOTE: -1 will be returned if the ARU is not communicating.
+
+ Values are represented in whole number degrees.
+ Units are displayed in the scale shown in
+ the rARUStatusSysTempUnits OID (Celsius or Fahrenheit)."
+ ::= { rARUStatusEntry 3 }
+
+rARUStatusAruManualSetpoint OBJECT-TYPE
+ SYNTAX INTEGER {
+ aruOff (1),
+ aru85F-29C (2),
+ aru90F-32C (3),
+ aru95F-35C (4),
+ aru100F-38C (5),
+ aru7kW (6),
+ aru5kW (7),
+ aru3kW (8),
+ aru2kW (9),
+ aruRem (10)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "ARU manual setpoint temperature setting.
+
+ NOTE: -1 will be returned if the ARU is not communicating.
+
+ Values are represented in whole number degrees.
+ If the manual setpoint is set to Remote, this OID will return 0.
+ Units are displayed in the scale shown in
+ the rARUStatusSysTempUnits OID (Celsius or Fahrenheit)."
+ ::= { rARUStatusEntry 4 }
+
+rARUStatusAruTemp1 OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "ARU temperature probe #1 reading.
+
+ NOTE: -1 will be returned if the ARU is not communicating.
+
+ Values are represented in whole number degrees.
+ Units are displayed in the scale shown in
+ the rARUStatusSysTempUnits OID (Celsius or Fahrenheit)."
+ ::= { rARUStatusEntry 5 }
+
+rARUStatusAruTemp2 OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "ARU temperature probe #2 reading.
+
+ NOTE: -1 will be returned if the ARU is not communicating.
+
+ Values are represented in whole number degrees.
+ Units are displayed in the scale shown in
+ the rARUStatusSysTempUnits OID (Celsius or Fahrenheit)."
+ ::= { rARUStatusEntry 6 }
+
+rARUStatusAruTemp3 OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "ARU temperature probe #3 reading.
+
+ NOTE: -1 will be returned if the ARU is not communicating.
+
+ Values are represented in whole number degrees.
+ Units are displayed in the scale shown in
+ the rARUStatusSysTempUnits OID (Celsius or Fahrenheit)."
+ ::= { rARUStatusEntry 7 }
+
+rARUStatusAruTempOvrdEnableDisable OBJECT-TYPE
+ SYNTAX INTEGER {
+ disabled(1),
+ enabled(2)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "This OID indicates whether the ARU remote temperature override is enabled or disabled.
+ If this OID is a 1, the remote setting for temperature override is disabled.
+ If this OID is a 2, the remote setting for temperature override is enabled."
+ ::= { rARUStatusEntry 8 }
+
+rARUStatusAruTempOvrdSetpoint OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "ARU remote temperature override setpoint setting.
+
+ NOTE: -1 will be returned if the ARU is not communicating.
+
+ Values are represented in whole number degrees.
+ Units are displayed in the scale shown in
+ the rARUStatusSysTempUnits OID (Celsius or Fahrenheit)."
+ ::= { rARUStatusEntry 9 }
+
+rARUStatusAruAlarmState OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "An ASCII string containing the 8 flags representing
+ the current alarm state of the ARU. If the state of
+ the ARU is unknown, this variable is set to ‘UNKNOWN’.
+
+ The flags are numbered 1 to 8, read from left to
+ right. The flags are defined as follows:
+
+ Flag 1: Fan Fail 1
+ Flag 2: Fan Fail 2
+ Flag 3: Fan Fail 3
+ Flag 4: Smoke
+
+ Flag 5: High Temp (Out of Thermal Control)
+ Flag 6: Over Temp (Exhaust Temp. Exceeds Override Setpoint)
+ Flag 7: Reserved
+ Flag 8: Reserved"
+ ::= { rARUStatusEntry 10 }
+
+rARUStatusAruCommStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ commsNeverDiscovered(1),
+ commsEstablished(2),
+ commsLost(3)
+ }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The state of communications to the device.
+ commNeverDiscovered(1) indicates there has never been communications with this device.
+ commsEstablished(2) indicates communication is normal and active with this device.
+ commsLost(3) indicates communication had been established, but is no device."
+ ::= { rARUStatusEntry 11 }
+
+-- Traps
+-- Annotations are provided for Novell's NMS product
+--
+-- Each trap has at least one variable (mtrapargsString) which always appears
+-- as the last variable in the list. This variable contains either a static
+-- or dynamically-constructed string which provides an enhanced description of
+-- the trap's purpose and any pertinent information about the trap.
+
+communicationLost TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString }
+ DESCRIPTION
+ "SEVERE: Communication to the UPS has been lost. Steps
+ to reestablish communication are in progress."
+ --#TYPE "APC UPS: Communication lost"
+ --#SUMMARY "Communication lost between the agent and the UPS."
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 1
+
+upsOverload TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString }
+ DESCRIPTION
+ "SEVERE: The UPS has sensed a load greater than 100 percent
+ of its rated capacity."
+ --#TYPE "APC UPS: Overload"
+ --#SUMMARY "The UPS has sensed a load greater than 100 percent of its rated capacity."
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 2
+
+upsDiagnosticsFailed TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString }
+ DESCRIPTION
+ "SEVERE: The UPS failed its internal diagnostic self-test."
+ --#TYPE "APC UPS: Failed self-test"
+ --#SUMMARY "The UPS has failed its internal self-test."
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 3
+
+upsDischarged TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString }
+ DESCRIPTION
+ "SEVERE: The UPS batteries are discharged; if utility power fails
+ an immediate low battery condition will exist. Sufficient runtime
+ for necessary action cannot be guaranteed."
+ --#TYPE "APC UPS: batteries are discharged"
+ --#SUMMARY "The UPS batteries are discharged."
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 4
+
+upsOnBattery TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString }
+ DESCRIPTION
+ "WARNING: The UPS has switched to battery backup power."
+ --#TYPE "APC UPS: On battery"
+ --#SUMMARY "The UPS has switched to battery backup power."
+ --#SEVERITY WARNING
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 5
+
+smartBoostOn TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString }
+ DESCRIPTION
+ "WARNING: The UPS has enabled SmartBoost(TM)."
+ --#TYPE "APC UPS: SmartBoost(TM)"
+ --#SUMMARY "The UPS has enabled SmartBoost(TM); low incoming line voltage."
+ --#SEVERITY WARNING
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 6
+
+lowBattery TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString }
+ DESCRIPTION
+ "SEVERE: The UPS batteries are low and will soon be exhausted.
+ If utility power is not restored the UPS will put itself
+ to 'sleep' and immediately cut power to the load."
+ --#TYPE "APC UPS: Low battery"
+ --#SUMMARY "The UPS system's batteries are low and will soon be exhausted."
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 7
+
+communicationEstablished TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: Communication with the UPS has been established."
+ --#TYPE "APC UPS: Communication established"
+ --#SUMMARY "UPS communication has been established."
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 8
+
+powerRestored TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: Utility power has been restored."
+ --#TYPE "APC UPS: Utility power restored"
+ --#SUMMARY "Returned from battery backup power; utility power restored."
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 9
+
+upsDiagnosticsPassed TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: The UPS passed its internal self-test."
+ --#TYPE "APC UPS: Passed self-test"
+ --#SUMMARY "The UPS passed internal self-test."
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 10
+
+returnFromLowBattery TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: The UPS has returned from a low battery
+ condition."
+ --#TYPE "APC UPS: Returned from Low-Battery condition"
+ --#SUMMARY "The UPS has returned from a Low-Battery condition."
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 11
+
+upsTurnedOff TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString }
+ DESCRIPTION
+ "WARNING: The UPS has been turned 'off' by the management station."
+ --#TYPE "APC UPS: Turned off"
+ --#SUMMARY "The UPS has been switched off by a management station."
+ --#SEVERITY WARNING
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE NONOPERATIONAL
+ ::= 12
+
+upsSleeping TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString }
+ DESCRIPTION
+ "WARNING: The UPS is entering 'sleep' mode. Power
+ to the load will be cut off."
+ --#TYPE "APC UPS: Entered sleep mode"
+ --#SUMMARY "The UPS entered sleep mode. Power to the load will be cut off."
+ --#SEVERITY WARNING
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE NONOPERATIONAL
+ ::= 13
+
+upsWokeUp TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString }
+ DESCRIPTION
+ "INFORMATION: The UPS has returned from 'sleep' mode. Power
+ to the load has been restored."
+ --#TYPE "APC UPS: Wake up"
+ --#SUMMARY "The UPS has returned from sleep mode. Power to the load has been restored."
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 14
+
+upsRebootStarted TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString }
+ DESCRIPTION
+ "WARNING: The UPS has started its reboot sequence.
+ The UPS will reboot itself at this time."
+ --#TYPE "APC UPS: Starting reboot"
+ --#SUMMARY "The UPS has started its reboot sequence."
+ --#SEVERITY WARNING
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE NONOPERATIONAL
+ ::= 15
+
+upsDipSwitchChanged TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString }
+ DESCRIPTION
+ "WARNING: The dip switch settings on the UPS have been
+ changed, possibly altering UPS performance."
+ --#TYPE "APC UPS: DIP switch altered"
+ --#SUMMARY "The DIP switch settings on the UPS have been changed."
+ --#SEVERITY WARNING
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 16
+
+upsBatteryNeedsReplacement TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString }
+ DESCRIPTION
+ "SEVERE: The batteries of the UPS need immediate replacement."
+ --#TYPE "APC UPS: UPS batteries need replacement"
+ --#SUMMARY "The UPS batteries require immediate replacement."
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 17
+
+
+-- the Environmental Monitor traps
+
+contactFault TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsInteger, mtrapargsString }
+ DESCRIPTION
+ "SEVERE: One of the contacts on the Environmental Monitor has
+ changed from its default position. The first variable is
+ the contact number that is faulted."
+ --#TYPE "APC Environment: Contact fault"
+ --#SUMMARY "An Environment contact closure has faulted."
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 18
+
+contactFaultResolved TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsInteger, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: A fault on one of the Environmental Monitor contacts
+ has been resolved. The first variable is
+ the contact number that has been resolved."
+ --#TYPE "APC Environment: Contact fault cleared."
+ --#SUMMARY "A Environment contact closure has returned to it's default state."
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 19
+
+-- the Matrix-UPS traps
+
+hardwareFailureBypass TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString }
+ DESCRIPTION
+ "SEVERE: UPS on bypass due to internal fault"
+ --#TYPE "APC UPS: On bypass due to internal fault"
+ --#SUMMARY "The UPS is on bypass due to an internal fault."
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 20
+
+softwareBypass TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString }
+ DESCRIPTION
+ "WARNING: UPS on bypass - user set via software or panel"
+ --#TYPE "APC UPS: On bypass by user via software or panel"
+ --#SUMMARY "UPS put on bypass by user via software or front UPS panel."
+ --#SEVERITY WARNING
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 21
+
+switchedBypass TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString }
+ DESCRIPTION
+ "WARNING: UPS on bypass - initiated by user"
+ --#TYPE "APC UPS: On bypass initiated by user"
+ --#SUMMARY "UPS put on bypass by user."
+ --#SEVERITY WARNING
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 22
+
+returnFromBypass TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: UPS has returned from bypass"
+ --#TYPE "APC UPS: UPS has returned from bypass"
+ --#SUMMARY "The UPS has returned from bypass mode."
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 23
+
+bypassPowerSupplyFailure TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString }
+ DESCRIPTION
+ "SEVERE: Base module bypass power supply needs repair"
+ --#TYPE "APC UPS: Base module bypass power supply needs repair"
+ --#SUMMARY "The base module bypass power supply needs repair."
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE NONOPERATIONAL
+ ::= 24
+
+baseFanFailure TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString }
+ DESCRIPTION
+ "SEVERE: Base module fan needs repair"
+ --#TYPE "APC UPS: Base module fan needs repair"
+ --#SUMMARY "The base module fan needs repair."
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE NONOPERATIONAL
+ ::= 25
+
+batteryPackCommLost TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString }
+ DESCRIPTION
+ "SEVERE: Check installation of external battery packs signal cable"
+ --#TYPE "APC UPS: Communication lost with battery packs"
+ --#SUMMARY "Communication lost with external battery packs, check battery signal cable."
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 26
+
+batteryPackCommEstablished TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: UPS is communicating with the external battery packs."
+ --#TYPE "APC UPS: Communication established with battery packs"
+ --#SUMMARY "Communication established with external battery packs."
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 27
+
+calibrationStart TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: A battery calibration test has been initiated on the UPS."
+ --#TYPE "APC UPS: Calibration initiated"
+ --#SUMMARY "A battery run time calibration test has been initiated."
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 28
+
+-- Misc. Traps
+
+restartAgent TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: Agent restarting as commanded by manager."
+ --#TYPE "APC SNMP Agent: Agent restarting"
+ --#SUMMARY "Agent restarting as commanded by manager."
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 29
+
+upsTurnedOn TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: A UPS is turned on."
+ --#TYPE "APC UPS: A UPS is turned on."
+ --#SUMMARY " A UPS is turned on."
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 30
+
+smartAvrReducing TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString }
+ DESCRIPTION
+ "WARNING: The UPS is reducing the line voltage via SmartTrim(TM)."
+ --#TYPE "APC UPS: SmartTrim(TM) reducing"
+ --#SUMMARY "The UPS has enabled SmartTrim(TM) voltage reduction."
+ --#SEVERITY WARNING
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 31
+
+codeAuthenticationDone TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mconfigTFTPServerIP, newCodeAuthentViaTFTP }
+ DESCRIPTION
+ "INFORMATIONAL: Authentication on agent code image is done."
+ --#TYPE "APC CODE: Authentication on agent code image is done."
+ --#SUMMARY "Authentication on agent code image is done."
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 32
+
+upsOverloadCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: The overload condition has been cleared."
+ --#TYPE "APC UPS: Overload cleared."
+ --#SUMMARY "The overload condition has been cleared. ."
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 33
+
+smartBoostOff TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: The UPS has returned from SmartBoost(TM)."
+ --#TYPE "APC UPS: SmartBoost(TM) off."
+ --#SUMMARY "The UPS has returned from SmartBoost(TM)."
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 34
+
+smartAvrReducingOff TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: The UPS has returned from SmartTrim(TM)."
+ --#TYPE "APC UPS: SmartTrim(TM) reducing off"
+ --#SUMMARY "The UPS has returned from SmartTrim(TM) voltage reduction."
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 35
+
+upsBatteryReplaced TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: A bad battery fault has been cleared."
+ --#TYPE "APC UPS: Bad battery replaced"
+ --#SUMMARY "The UPS has returned from a bad battery fault."
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 36
+
+calibrationEnd TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: The UPS has finished calibrating."
+ --#TYPE "APC UPS: Calibration end"
+ --#SUMMARY "The UPS has finished calibrating"
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 37
+
+dischargeCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: A UPS discharge condition has been cleared."
+ --#TYPE "APC UPS: Discharge cleared."
+ --#SUMMARY "The UPS discharge condition has been cleared."
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 38
+
+gracefullShutdown TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: A graceful shutdown has been initiated."
+ --#TYPE "APC UPS: A graceful shutdown has been initiated."
+ --#SUMMARY "A graceful shutdown has been initiated."
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 39
+
+
+outletOn TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { sPDUOutletControlIndex }
+ DESCRIPTION
+ "WARNING: The specified PDU outlet has turned on.
+ If sPDUOutletControlIndex equals zero, then all outlets have
+ turned on."
+ --#TYPE "APC PDU: Outlet has been turned on."
+ --#SUMMARY "Outlet has been turned on"
+ --#SEVERITY WARNING
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 41
+
+
+outletOff TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { sPDUOutletControlIndex }
+ DESCRIPTION
+ "WARNING: The specified PDU outlet has turned off.
+ If sPDUOutletControlIndex equals zero, then all outlets
+ have turned off."
+ --#TYPE "APC PDU: Outlet has turned off."
+ --#SUMMARY "Outlet has turned off."
+ --#SEVERITY WARNING
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 42
+
+outletReboot TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { sPDUOutletControlIndex }
+ DESCRIPTION
+ "WARNING: The specified PDU outlet has rebooted.
+ If sPDUOutletControlIndex equals zero, then all outlets
+ have rebooted."
+ --#TYPE "APC PDU: Outlet has rebooted."
+ --#SUMMARY "Outlet has rebooted."
+ --#SEVERITY WARNING
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 43
+
+configChangeSNMP TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString }
+ DESCRIPTION
+ "WARNING: The SNMP configuration has been changed."
+ --#TYPE "APC: The SNMP configuration has been changed."
+ --#SUMMARY "The SNMP configuration has been changed."
+ --#SEVERITY WARNING
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 44
+
+
+configChangeOutlet TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { sPDUOutletConfigIndex }
+ DESCRIPTION
+ "WARNING: The specified PDU outlet has changed configuration.
+ If sPDUOutletConfigIndex equals zero, then the Master outlet
+ has changed configuration."
+ --#TYPE "APC PDU: Outlet configuration has been changed."
+ --#SUMMARY "Outlet configuration has been changed."
+ --#SEVERITY WARNING
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 45
+
+accessViolationConsole TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString }
+ DESCRIPTION
+ "WARNING: Someone has attempted to login via the console with the incorrect password."
+ --#TYPE "APC: Access violation via the console."
+ --#SUMMARY "Three unsuccessful logins have been attempted via the console."
+ --#SEVERITY WARNING
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 46
+
+accessViolationHTTP TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString }
+ DESCRIPTION
+ "WARNING: Someone has attempted to login via HTTP with the incorrect password."
+ --#TYPE "APC: Access violation via HTTP."
+ --#SUMMARY "An unsuccessful attempt to login via HTTP."
+ --#SEVERITY WARNING
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 47
+
+passwordChange TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString }
+ DESCRIPTION
+ "WARNING: The password for the device has been changed."
+ --#TYPE "APC: Password change for the device."
+ --#SUMMARY "Someone has changed the password on the device."
+ --#SEVERITY WARNING
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 48
+
+badVoltage TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString }
+ DESCRIPTION
+ "WARNING: The output voltage is not within acceptable range."
+ --#TYPE "APC UPS: Bad output voltage."
+ --#SUMMARY "The output voltage is not within acceptable range."
+ --#SEVERITY WARNING
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 49
+
+badVoltageCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: The output voltage has returned to an acceptable level."
+ --#TYPE "APC UPS: The bad voltage output condition has been cleared."
+ --#SUMMARY "The output voltage has returned to an acceptable level."
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 50
+
+chargerFailure TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString }
+ DESCRIPTION
+ "WARNING: The battery charger has failed."
+ --#TYPE "APC UPS: The battery charger has failed."
+ --#SUMMARY "The battery charger has failed."
+ --#SEVERITY WARNING
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 51
+
+chargerFailureCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: The battery charger failure condition has been cleared."
+ --#TYPE "APC UPS: The battery charger failure condition cleared"
+ --#SUMMARY "The battery charger failure condition has been cleared."
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 52
+
+batteryOverTemperature TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString }
+ DESCRIPTION
+ "WARNING: The battery temperature threshold has been violated."
+ --#TYPE "APC UPS: The battery temperature threshold has been violated."
+ --#SUMMARY "The battery temperature threshold has been violated."
+ --#SEVERITY WARNING
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 53
+
+batteryOverTemperatureCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: The battery over temperature has been cleared."
+ --#TYPE "APC UPS: The battery over temperature has been cleared."
+ --#SUMMARY "The battery over temperature has been cleared."
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 54
+
+ smartRelayFault TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString }
+ DESCRIPTION
+ "WARNING: SmartBoost(TM) or SmartTrim(TM) relay fault."
+ --#TYPE "APC UPS: SmartBoost(TM) or SmartTrim(TM) relay fault."
+ --#SUMMARY "SmartBoost(TM) or SmartTrim(TM) relay fault."
+ --#SEVERITY WARNING
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 55
+
+smartRelayFaultCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: SmartBoost(TM) or SmartTrim(TM) relay fault has been cleared."
+ --#TYPE "APC UPS: SmartBoost(TM) or SmartTrim(TM) relay fault cleared."
+ --#SUMMARY "SmartBoost(TM) or SmartTrim(TM) relay fault has been cleared."
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 56
+
+humidityThresholdViolation1 TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsInteger, mtrapargsString }
+ DESCRIPTION
+ "SEVERE: Probe 1 humidity threshold violated. The
+ first variable is the current humidity."
+ --#TYPE "APC Environmental Monitor: Probe 1 humidity threshold violation"
+ --#SUMMARY "A humidity threshold has been violated on probe 1."
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 57
+
+humidityThresholdViolationCleared1 TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: An Environmental Monitor humidity threshold violation has been cleared on probe 1."
+ --#TYPE "APC Environmental Monitor: Probe 1 humidity violation cleared"
+ --#SUMMARY "A humidity threshold violation has been cleared on probe 1."
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 58
+
+temperatureThresholdViolation1 TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsInteger, mtrapargsString }
+ DESCRIPTION
+ "SEVERE: An Environmental Monitor temperature threshold has been violated on probe 1.
+ The first variable is the current temperature."
+ --#TYPE "APC Environmental Monitor: Probe 1 temperature violation"
+ --#SUMMARY "A temperature threshold has been violated on probe 1."
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 59
+
+temperatureThresholdViolationCleared1 TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: An Environmental Monitor temperature threshold violation has been cleared on probe 1."
+ --#TYPE "APC Environmental Monitor: Probe 1 temperature violation cleared"
+ --#SUMMARY "A temperature threshold violation has been cleared on probe 1."
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 60
+
+humidityThresholdViolation2 TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsInteger, mtrapargsString }
+ DESCRIPTION
+ "SEVERE: An Environmental Monitor humidity threshold has been violated on probe 2.
+ The first variable is the current humidity."
+ --#TYPE "APC Environmental Monitor: Probe 2 humidity violation"
+ --#SUMMARY "A humidity threshold has been violated on probe 2."
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 61
+
+humidityThresholdViolationCleared2 TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: An Environmental Monitor humidity threshold violation has been cleared on probe 2."
+ --#TYPE "APC Environmental Monitor: Probe 2 humidity violation cleared"
+ --#SUMMARY "A humidity threshold violation has been cleared on probe 2."
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 62
+
+temperatureThresholdViolation2 TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsInteger, mtrapargsString }
+ DESCRIPTION
+ "SEVERE: An Environmental Monitor temperature threshold has been violated on probe 2.
+ The first variable is the current temperature."
+ --#TYPE "APC Environmental Monitor: Probe 2 temperature violation"
+ --#SUMMARY "A temperature threshold has been violated on probe 2."
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 63
+
+temperatureThresholdViolationCleared2 TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: An Environmental Monitor temperature threshold violation has been cleared on probe 2."
+ --#TYPE "APC Environmental Monitor: Probe 2 temperature violation cleared"
+ --#SUMMARY "A temperature threshold violation has been cleared on probe 2."
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 64
+
+mupsCommunicationEstablished TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: Communication with the Environmental Monitor has been established."
+ --#TYPE "APC Environmental Monitor: Communication established"
+ --#SUMMARY "Communication established between the agent and the Environmental Monitor."
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 65
+
+mupsCommunicationLost TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString }
+ DESCRIPTION
+ "SEVERE: Communication to the Environmental Monitor has been lost. Steps
+ to reestablish communication are in progress."
+ --#TYPE "APC Environmental Monitor: Communication failure"
+ --#SUMMARY "Communication lost between the agent and the Environmental Monitor."
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 66
+
+batteryIncrease TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: The number of batteries has increased."
+ --#TYPE "APC UPS: The number of batteries has increased."
+ --#SUMMARY "The number of batteries has increased."
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 67
+
+batteryDecrease TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: The number of batteries has decreased."
+ --#TYPE "APC UPS: The number of batteries has decreased."
+ --#SUMMARY "The number of batteries has decreased."
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 68
+
+powerModuleIncrease TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: The number of power modules has increased."
+ --#TYPE "APC UPS: The number of power modules has increased."
+ --#SUMMARY "The number of power modules has increased."
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 69
+
+powerModuleDecrease TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: The number of power modules has decreased."
+ --#TYPE "APC UPS: The number of power modules has decreased."
+ --#SUMMARY "The number of power modules has decreased."
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 70
+
+intelligenceModuleInserted TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: An intelligence module has been inserted."
+ --#TYPE "APC UPS: An intelligence module has been inserted."
+ --#SUMMARY "An intelligence module has been inserted."
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 71
+
+intelligenceModuleRemoved TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: An intelligence module has been removed."
+ --#TYPE "APC UPS: An intelligence module has been removed."
+ --#SUMMARY "An intelligence module has been removed."
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 72
+
+rintelligenceModuleInserted TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: A redundant intelligence module has been inserted."
+ --#TYPE "APC UPS: A redundant intelligence module has been inserted."
+ --#SUMMARY "A redundant intelligence module has been inserted."
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 73
+
+rintelligenceModuleRemoved TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: A redundant intelligence module has been removed."
+ --#TYPE "APC UPS: A redundant intelligence module has been removed."
+ --#SUMMARY "A redundant intelligence module has been removed."
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 74
+
+extBatteryFrameIncease TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: An external battery frame has been added."
+ --#TYPE "APC UPS: An external battery frame has been added."
+ --#SUMMARY "An external battery frame has been added."
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 75
+
+extBatteryFrameDecrease TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: An external battery frame has been removed."
+ --#TYPE "APC UPS: An external battery frame has been removed."
+ --#SUMMARY "An external battery frame has been removed."
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 76
+
+abnormalCondition TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsInteger, mtrapargsString }
+ DESCRIPTION
+ "SEVERE: An abnormal condition has been detected.
+ The first variable is the fault condition."
+ --#TYPE "APC: An abnormal condition has been detected."
+ --#SUMMARY "An abnormal condition has been detected."
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 77
+
+abnormalConditionCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsInteger, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: An abnormal condition has been cleared.
+ The first variable is the fault condition."
+ --#TYPE "APC: An abnormal condition has been cleared."
+ --#SUMMARY "An abnormal condition has been cleared."
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 78
+
+deviceStatusChange TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString}
+ DESCRIPTION
+ "INFORMATIONAL: The status of the device being monitored has changed."
+ --#TYPE "APC : The status of the device being monitored has changed."
+ --#SUMMARY "The status of the device being monitored has changed."
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 79
+
+noBatteries TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString }
+ DESCRIPTION
+ "WARNING: The UPS has no batteries attached."
+ --#TYPE "APC UPS: No batteries attached."
+ --#SUMMARY "The UPS has no batteries attached."
+ --#SEVERITY WARNING
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 80
+
+noBatteriesCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: The UPS's batteries have been attached."
+ --#TYPE "APC UPS: The no batteries attached condition has been cleared."
+ --#SUMMARY "The UPS's batteries have been attached."
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 81
+
+userAdded TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: A new user has been added."
+ --#TYPE "APC: A new user has been added."
+ --#SUMMARY "A new user has been added."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 82
+
+userDeleted TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: A user has been deleted."
+ --#TYPE "APC: A user has been deleted."
+ --#SUMMARY "A user has been deleted."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 83
+
+userModified TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: A user has been modified."
+ --#TYPE "APC: A user has been modified."
+ --#SUMMARY "A user has been modified."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 84
+
+-- MasterSwitch Vm Traps
+
+msvmCommunicationEstablished TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { sPDUMasterControlVMIndex, sPDUMasterControlVMName, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: Communications with the MasterSwitch VM has been established."
+ --#TYPE "APC: Communications established with the MasterSwitch VM."
+ --#SUMMARY "Communications with the MasterSwitch VM has been established."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 85
+
+msvmCommunicationLost TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { sPDUMasterControlVMIndex, sPDUMasterControlVMName, mtrapargsString }
+ DESCRIPTION
+ "SEVERE: Communications with the MasterSwitch VM has been lost."
+ --#TYPE "APC: Communications lost with the MasterSwitch VM."
+ --#SUMMARY "Communications with the MasterSwitch VM has been lost."
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 86
+
+msvmOverload TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { sPDUMasterControlVMIndex, sPDUMasterControlVMName, mtrapargsString }
+ DESCRIPTION
+ "SEVERE: The MasterSwitch VM in an overload condition."
+ --#TYPE "APC: The MasterSwitch VM is near or at an overload condition."
+ --#SUMMARY "The MasterSwitch VM is near or at an overload condition."
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 87
+
+msvmOverloadCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { sPDUMasterControlVMIndex, sPDUMasterControlVMName, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: The overload condition on the MasterSwitch VM has been cleared."
+ --#TYPE "APC: The overload condition cleared on the MasterSwitch VM."
+ --#SUMMARY "The overload condition on the MasterSwitch VM has been cleared."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 88
+
+msvmOutletOn TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { sPDUMasterControlVMIndex, sPDUMasterControlVMName,
+ sPDUOutletControlVMOutletIndex, sPDUOutletControlVMOutletName, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: An outlet on the MasterSwitch VM has turned on."
+ --#TYPE "APC: An outlet on the MasterSwitch VM has turned on."
+ --#SUMMARY "An outlet on the MasterSwitch VM has turned on."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 89
+
+msvmOutletOff TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { sPDUMasterControlVMIndex, sPDUMasterControlVMName,
+ sPDUOutletControlVMOutletIndex, sPDUOutletControlVMOutletName, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: An outlet on the MasterSwitch VM has turned off."
+ --#TYPE "APC: An outlet on the MasterSwitch VM has turned off."
+ --#SUMMARY "An outlet on the MasterSwitch VM has turned off."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 90
+
+msvmDeviceConfigChange TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { sPDUMasterControlVMIndex, sPDUMasterControlVMName, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: A device configuration change has been made on a MasterSwitch VM."
+ --#TYPE "APC: A device configuration change on a MasterSwitch VM."
+ --#SUMMARY "A device configuration change has been made on a MasterSwitch VM."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 91
+
+msvmOutletConfigChange TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { sPDUMasterControlVMIndex, sPDUMasterControlVMName,
+ sPDUOutletControlVMOutletIndex, sPDUOutletControlVMOutletName, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: An outlet configuration change has been made on a MasterSwitch VM."
+ --#TYPE "APC: An outlet configuration change on a MasterSwitch VM."
+ --#SUMMARY "An outlet configuration change has been made on a MasterSwitch VM."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 92
+
+msvmLowLoad TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { sPDUMasterControlVMIndex, sPDUMasterControlVMName, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: The MasterSwitch VM has violated the low load threshold."
+ --#TYPE "APC: The MasterSwitch VM has violated the low load threshold."
+ --#SUMMARY "The MasterSwitch VM has violated the low load threshold."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 93
+
+msvmLowLoadCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { sPDUMasterControlVMIndex, sPDUMasterControlVMName, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: The low load condition on the MasterSwitch VM has been cleared."
+ --#TYPE "APC: The low load condition cleared on the MasterSwitch VM."
+ --#SUMMARY "The low load condition on the MasterSwitch VM has been cleared."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 94
+
+msvmNearOverload TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { sPDUMasterControlVMIndex, sPDUMasterControlVMName, mtrapargsString }
+ DESCRIPTION
+ "SEVERE: The MasterSwitch VM is approaching an overload condition."
+ --#TYPE "APC: The MasterSwitch VM is near or at an overload condition."
+ --#SUMMARY "The MasterSwitch VM is near or at an overload condition."
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 95
+
+msvmNearOverloadCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { sPDUMasterControlVMIndex, sPDUMasterControlVMName, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: The near overload condition on the MasterSwitch VM has been cleared."
+ --#TYPE "APC: The overload condition cleared on the MasterSwitch VM."
+ --#SUMMARY "The overload condition on the MasterSwitch VM has been cleared."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 96
+
+msvmPowerSupplyStatusChange TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { sPDUMasterControlVMIndex, sPDUMasterControlVMName, mtrapargsInteger, mtrapargsString }
+ DESCRIPTION
+ "WARNING: The power supply status of the MasterSwitch VM has changed."
+ --#TYPE "APC: The power supply status changed on MasterSwitch VM"
+ --#SUMMARY "The power supply status of the MasterSwitch VM has changed."
+ --#ARGUMENTS { }
+ --#SEVERITY WARNING
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 97
+
+-- MasterSwitch plus (MSP) Traps
+
+mspCommunicationEstablished TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { sPDUMasterControlMSPIndex, sPDUMasterControlMSPName, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: Communications with the MasterSwitch plus has been established."
+ --#TYPE "APC: Communications established with the MasterSwitch plus."
+ --#SUMMARY "Communications with the MasterSwitch plus has been established."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 98
+
+mspCommunicationLost TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { sPDUMasterControlMSPIndex, sPDUMasterControlMSPName, mtrapargsString }
+ DESCRIPTION
+ "SEVERE: Communications with the MasterSwitch plus has been lost."
+ --#TYPE "APC: Communications lost with the MasterSwitch plus."
+ --#SUMMARY "Communications with the MasterSwitch plus has been lost."
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 99
+
+mspOutletOn TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { sPDUMasterControlMSPIndex, sPDUMasterControlMSPName,
+ sPDUOutletControlMSPOutletIndex, sPDUOutletControlMSPOutletName, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: An outlet on the MasterSwitch plus has turned on."
+ --#TYPE "APC: An outlet on the MasterSwitch plus has turned on."
+ --#SUMMARY "An outlet on the MasterSwitch plus has turned on."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 100
+
+mspOutletOff TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { sPDUMasterControlMSPIndex, sPDUMasterControlMSPName,
+ sPDUOutletControlMSPOutletIndex, sPDUOutletControlMSPOutletName, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: An outlet on the MasterSwitch plus has turned off."
+ --#TYPE "APC: An outlet on the MasterSwitch plus has turned off."
+ --#SUMMARY "An outlet on the MasterSwitch plus has turned off."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 101
+
+mspDeviceConfigChange TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { sPDUMasterControlMSPIndex, sPDUMasterControlMSPName, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: A device configuration change has been made on a MasterSwitch plus."
+ --#TYPE "APC: A device configuration change on a MasterSwitch plus."
+ --#SUMMARY "A device configuration change has been made on a MasterSwitch plus."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 102
+
+mspOutletConfigChange TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { sPDUMasterControlMSPIndex, sPDUMasterControlMSPName, sPDUOutletControlMSPOutletIndex, sPDUOutletControlMSPOutletName, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: An outlet configuration change has been made on a MasterSwitch plus."
+ --#TYPE "APC: An outlet configuration change on a MasterSwitch plus."
+ --#SUMMARY "An outlet configuration change has been made on a MasterSwitch plus."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 103
+
+rsSourceSwitched TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsInteger02, mtrapargsString03, mtrapargsInteger, mtrapargsString02, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: The Redundant Switch has switched source.
+ The first variable is an integer representing the current source: 0=A, 1=B.
+ The second variable is the 32-character name of the current source.
+ The third variable is an integer representing the transfer cause:
+ 0=No Transfers Recorded, 1=Due to user action or preferred switching,
+ 3=Due to line notch or spike, 5=Due to low line voltage,
+ 7=Transfer due to high line voltage,
+ 9=Transfer due to frequency out of range.
+ The fourth variable is a character string listing the transfer cause."
+ --#TYPE "APC Redundant Switch: The Redundant Switch has switched source"
+ --#SUMMARY "The Redundant Switch has switched source."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 104
+
+rsLostRedundancy TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsInteger, mtrapargsString02, mtrapargsString }
+ DESCRIPTION
+ "SEVERE: The Redundant Switch has lost redundancy.
+ The first variable is an integer representing the source which is no longer available: 0=A, 1=B.
+ The second variable is the 32-character name of the source which is no longer available."
+ --#TYPE "APC Redundant Switch: The Redundant Switch has lost redundancy"
+ --#SUMMARY "The Redundant Switch has has lost redundancy."
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 105
+
+rsRedundancyRestored TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsInteger, mtrapargsString02, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: Redundancy has been restored to the Redundant Switch .
+ The first variable is an integer representing the source which has been restored: 0=A, 1=B.
+ The second variable is the 32-character name of the source which has been restored."
+ --#TYPE "APC Redundant Switch: Redundancy has been restored."
+ --#SUMMARY "Redundancy has been restored to the Redundant Switch ."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 106
+
+rsConfigChange TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: A configuration change has been made on a Redundant Switch."
+ --#TYPE "APC: A configuration change on a Redundant Switch."
+ --#SUMMARY "A configuration change has been made on a Redundant Switch."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 107
+
+rsCommunicationEstablished TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: Communications with the Redundant Switch has been established."
+ --#TYPE "APC: Communications established with the Redundant Switch."
+ --#SUMMARY "Communications with the Redundant Switch has been established."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 108
+
+rsCommunicationLost TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString }
+ DESCRIPTION
+ "SEVERE: Communications with the Redundant Switch has been lost."
+ --#TYPE "APC: Communications lost with the Redundant Switch."
+ --#SUMMARY "Communications with the Redundant Switch has been lost."
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 109
+
+dcCommunicationEstablished TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: Communications with the DC power plant has been established."
+ --#TYPE "APC: Communications established with the DC power plant."
+ --#SUMMARY "Communications with the DC power plant has been established."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 110
+
+dcCommunicationLost TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString }
+ DESCRIPTION
+ "SEVERE: Communications with the DC power plant has been lost."
+ --#TYPE "APC: Communications lost with the DC power plant."
+ --#SUMMARY "Communications with the DC power plant has been lost."
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 111
+
+dcPINChanged TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: The active PIN on the DC controller has been changed."
+ --#TYPE "APC: The active PIN on the DC controller has been changed."
+ --#SUMMARY "The active PIN on the DC controller has been changed."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 112
+
+dcMajorAlarm TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString }
+ DESCRIPTION
+ "SEVERE: A Major alarm is active in the DC power plant."
+ --#TYPE "APC: A Major alarm is active in the DC power plant."
+ --#SUMMARY "A Major alarm is active in the DC power plant."
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 113
+
+dcMajorAlarmCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: A Major alarm is no longer active in the DC power plant."
+ --#TYPE "APC: A Major alarm is no longer active in the DC power plant."
+ --#SUMMARY "A Major alarm is no longer active in the DC power plant."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 114
+
+dcMinorAlarm TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString }
+ DESCRIPTION
+ "WARNING: A Minor alarm is active in the DC power plant."
+ --#TYPE "APC: A Minor alarm is active in the DC power plant."
+ --#SUMMARY "A Minor alarm is active in the DC power plant."
+ --#ARGUMENTS { }
+ --#SEVERITY WARNING
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 115
+
+dcMinorAlarmCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: A Minor alarm is no longer active in the DC power plant."
+ --#TYPE "APC: A Minor alarm is no longer active in the DC power plant."
+ --#SUMMARY "A Minor alarm is no longer active in the DC power plant."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 116
+
+dcOutputRelayOn TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { dm3StatusOutRlyIndex, dm3StatusOutRlyName, mtrapargsString }
+ DESCRIPTION
+ "WARNING: An output relay for the powerplant has been activated (state changed to on).
+ The first variable is an integer representing the output relay number that has gone on.
+ The second variable is the 16-character name of the output relay."
+ --#TYPE "APC: An output relay has gone on."
+ --#SUMMARY "An output relay has gone on in the DC power plant."
+ --#ARGUMENTS { }
+ --#SEVERITY WARNING
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 117
+
+dcOutputRelayOff TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { dm3StatusOutRlyIndex, dm3StatusOutRlyName, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: An output relay for the powerplant has been deactivated (state changed to off).
+ The first variable is an integer representing the output relay number that has gone off.
+ The second variable is the 16-character name of the output relay."
+ --#TYPE "APC: An output relay has gone off."
+ --#SUMMARY "An output relay has gone off in the DC power plant."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 118
+
+dcInputRelayOn TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { dm3StatusInRlyIndex, dm3StatusInRlyName, mtrapargsString }
+ DESCRIPTION
+ "WARNING: An input relay for the powerplant has been activated (state changed to on).
+ The first variable is an integer representing the input relay number that has gone on.
+ The second variable is the 16-character name of the input relay."
+ --#TYPE "APC: An input relay has gone on."
+ --#SUMMARY "An input relay has gone on in the DC power plant."
+ --#ARGUMENTS { }
+ --#SEVERITY WARNING
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 119
+
+dcInputRelayOff TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { dm3StatusInRlyIndex, dm3StatusInRlyName, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: An input relay for the powerplant has been deactivated (state changed to off).
+ The first variable is an integer representing the input relay number that has gone off.
+ The second variable is the 16-character name of the input relay."
+ --#TYPE "APC: An input relay has gone off."
+ --#SUMMARY "An input relay has gone off in the DC power plant."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 120
+
+logicPowerSuppliesIncreased TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: The number of system power supplies has increased."
+ --#TYPE "APC UPS: The number of system power supplies has increased."
+ --#SUMMARY "The number of system power supplies has increased."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 121
+
+logicPowerSuppliesDecreased TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: The number of system power supplies has decreased."
+ --#TYPE "APC UPS: The number of system power supplies has decreased."
+ --#SUMMARY "The number of system power supplies has decreased."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 122
+
+externalSwitchGearClosed TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString02, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: External Switch Gear closed."
+ --#TYPE "APC UPS: External Switch Gear closed."
+ --#SUMMARY "External Switch Gear closed."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 123
+
+externalSwitchGearOpened TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString02, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: External Switch Gear opened."
+ --#TYPE "APC UPS: External Switch Gear opened."
+ --#SUMMARY "External Switch Gear opened."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 124
+
+generalDeviceEvent TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: APC Device event."
+ --#TYPE "APC Device event"
+ --#SUMMARY "APC Device event."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 125
+
+atsSourceSwitched TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsInteger, mtrapargsString02, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: The Automatic Transfer Switch has switched source.
+ The first variable is an integer representing the current source: 0=A, 1=B.
+ The second variable is the 32-character name of the current source."
+ --#TYPE "APC Automatic Transfer Switch: The ATS has switched source"
+ --#SUMMARY "The Automatic Transfer Switch has switched source."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 126
+
+atsLostRedundancy TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsInteger, mtrapargsString02, mtrapargsString }
+ DESCRIPTION
+ "SEVERE: The Automatic Transfer Switch has lost redundancy.
+ The first variable is an integer representing the source which is no longer available: 0=A, 1=B.
+ The second variable is the 32-character name of the source which is no longer available."
+ --#TYPE "APC Automatic Transfer Switch: The ATS has lost redundancy. "
+ --#SUMMARY "The Automatic Transfer Switch has has lost redundancy."
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 127
+
+atsRedundancyRestored TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsInteger, mtrapargsString02, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: Redundancy has been restored to the Automatic Transfer Switch .
+ The first variable is an integer representing the source which has been restored: 0=A, 1=B.
+ The second variable is the 32-character name of the source which has been restored."
+ --#TYPE "APC Automatic Transfer Switch: Redundancy has been restored."
+ --#SUMMARY "Redundancy has been restored to the Automatic Transfer Switch ."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 128
+
+atsConfigChange TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsInteger, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: A configuration change has been made on the Automatic Transfer Switch.
+ The first variable is an integer representing the configuration setting which changed:
+ 0=Transfer Voltage Range, 1=Sensitivity 2=Preferred Source
+ 3=Front Panel Lockout 4=Current Limit"
+ --#TYPE "APC Automatic Transfer Switch: ATS configuration changed."
+ --#SUMMARY "A configuration change has been made on a Automatic Transfer Switch."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 129
+
+atsCommunicationEstablished TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: Communications with the Automatic Transfer Switch has been established."
+ --#TYPE "APC Automatic Transfer Switch: Communications established."
+ --#SUMMARY "Communications with the Automatic Transfer Switch has been established."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 130
+
+atsCommunicationLost TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString }
+ DESCRIPTION
+ "SEVERE: Communications with the Automatic Transfer Switch has been lost."
+ --#TYPE "APC Automatic Transfer Switch: Communications lost."
+ --#SUMMARY "Communications with the Automatic Transfer Switch has been lost."
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 131
+
+atsOverCurrent TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString }
+ DESCRIPTION
+ "SEVERE: Output Current has exceeded threshold."
+ --#TYPE "APC Automatic Transfer Switch: Output Current exceeded threshold"
+ --#SUMMARY "Output Current has exceeded Threshold. "
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 132
+
+atsOverCurrentCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: Output Current has returned below threshold."
+ --#TYPE "APC Automatic Transfer Switch: Output Current below threshold."
+ --#SUMMARY "Output Current has returned below threshold."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 133
+
+atsPowerSupplyFailure TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsInteger, mtrapargsString }
+ DESCRIPTION
+ "SEVERE: The Automatic Transfer Switch Power Supply has failed.
+ The first variable is an integer representing the Power Supply which
+ has failed: 0=24V, 1=12V 2=5V."
+ --#TYPE "APC Automatic Transfer Switch: The ATS Power Supply has failed."
+ --#SUMMARY "The Automatic Transfer Switch Power Supply has failed."
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 134
+
+atsPowerSupplyFailureCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsInteger, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: The Automatic Transfer Power Supply Failure Cleared.
+ The first variable is an integer representing the Power Supply which
+ has cleared: 0=24V, 1=12V 2=5V."
+ --#TYPE "APC Automatic Transfer Switch: Power Supply Failure Cleared."
+ --#SUMMARY "The Automatic Transfer Switch Power Supply Failure Cleared."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 135
+
+dcMainsFailAlarm TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString }
+ DESCRIPTION
+ "WARNING: A Mains Fail alarm is active in the DC power plant."
+ --#TYPE "APC: A Mains Fail alarm is active in the DC power plant."
+ --#SUMMARY "A Mains Fail alarm is active in the DC power plant."
+ --#ARGUMENTS { }
+ --#SEVERITY WARNING
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 136
+
+dcMainsFailAlarmCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: Mains Fail alarm is no longer active in the DC power plant."
+ --#TYPE "APC: Mains Fail alarm is no longer active in the DC power plant."
+ --#SUMMARY "Mains Fail alarm is no longer active in the DC power plant."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 137
+
+dcFanFailAlarm TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString }
+ DESCRIPTION
+ "WARNING: A Fan Fail alarm is active in the DC power plant."
+ --#TYPE "APC: A Fan Fail alarm is active in the DC power plant."
+ --#SUMMARY "A Fan Fail alarm is active in the DC power plant."
+ --#ARGUMENTS { }
+ --#SEVERITY WARNING
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 138
+
+dcFanFailAlarmCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: A Fan Fail alarm is no longer active in the DC power plant."
+ --#TYPE "APC: A Fan Fail alarm is no longer active in the DC power plant."
+ --#SUMMARY "A Fan Fail alarm is no longer active in the DC power plant."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 139
+
+dcRectifierOvertempAlarm TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString }
+ DESCRIPTION
+ "WARNING: Rect. Overtemp alarm is active in the power plant."
+ --#TYPE "APC: Rect. Overtemp alarm is active in the power plant."
+ --#SUMMARY "Rect. Overtemp alarm is active in the power plant."
+ --#ARGUMENTS { }
+ --#SEVERITY WARNING
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 140
+
+dcRectifierOvertempAlarmCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: Rect. Overtemp alarm is no longer active in the power plant."
+ --#TYPE "APC: Rect. Overtmp alarm is no longer active in the power plant."
+ --#SUMMARY "Rect. Overtmp alarm is no longer active in the power plant."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 141
+
+dcCurrentLimitAlarm TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString }
+ DESCRIPTION
+ "WARNING: A Current Limit alarm is active in the power plant."
+ --#TYPE "APC: A Current Limit alarm is active in the power plant."
+ --#SUMMARY "A Current Limit alarm is active in the power plant."
+ --#ARGUMENTS { }
+ --#SEVERITY WARNING
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 142
+
+dcCurrentLimitAlarmCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: Current Limit alarm is no longer active in the power plant."
+ --#TYPE "APC: Current Limit alarm is no longer active in the power plant."
+ --#SUMMARY "Current Limit alarm is no longer active in the power plant."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 143
+
+dcRectifierFailAlarm TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString }
+ DESCRIPTION
+ "WARNING: A Rect. Fail alarm is active in the power plant."
+ --#TYPE "APC: A Rect. Fail alarm is active in the power plant."
+ --#SUMMARY "A Rect. Fail alarm is active in the power plant."
+ --#ARGUMENTS { }
+ --#SEVERITY WARNING
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 144
+
+dcRectifierFailAlarmCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: Rect. Fail alarm is no longer active in the power plant."
+ --#TYPE "APC: Rect. Fail alarm is no longer active in the power plant."
+ --#SUMMARY "Rect. Fail alarm is no longer active in the power plant."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 145
+
+dcMultRectFailAlarm TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString }
+ DESCRIPTION
+ "WARNING: Multiple Rect. Fail alarm is active in the powerplant."
+ --#TYPE "APC: Multiple Rect. Fail alarm is active in the powerplant."
+ --#SUMMARY "Multiple Rect. Fail alarm is active in the powerplant."
+ --#ARGUMENTS { }
+ --#SEVERITY WARNING
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 146
+
+dcMultRectFailAlarmCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: Mult Rect Fail alarm is no longer active in the powerplant."
+ --#TYPE "APC: Mult Rect Fail alarm is no longer active in the powerplant."
+ --#SUMMARY "Mult Rect Fail alarm is no longer active in the powerplant."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 147
+
+dcBatteryBreakerAlarm TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString }
+ DESCRIPTION
+ "WARNING: Batt. Breaker alarm is active in the power plant."
+ --#TYPE "APC: Batt. Breaker alarm is active in the power plant."
+ --#SUMMARY "Batt. Breaker alarm is active in the power plant."
+ --#ARGUMENTS { }
+ --#SEVERITY WARNING
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 148
+
+dcBatteryBreakerAlarmCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: Batt. Breaker alarm is no longer active in the power plant."
+ --#TYPE "APC: Batt. Breaker alarm is no longer active in the power plant."
+ --#SUMMARY "Batt. Breaker alarm is no longer active in the power plant."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 149
+
+dcRectifierOVPAlarm TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString }
+ DESCRIPTION
+ "WARNING: A Rect. OVP alarm is active in the power plant."
+ --#TYPE "APC: A Rect. OVP alarm is active in the power plant."
+ --#SUMMARY "A Rect. OVP alarm is active in the power plant."
+ --#ARGUMENTS { }
+ --#SEVERITY WARNING
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 150
+
+dcRectifierOVPAlarmCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: A Rect. OVP alarm is no longer active in the power plant."
+ --#TYPE "APC: A Rect. OVP alarm is no longer active in the power plant."
+ --#SUMMARY "A Rect. OVP alarm is no longer active in the power plant."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 151
+
+dcLVDImminentAlarm TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString }
+ DESCRIPTION
+ "WARNING: A LVD Imminent alarm is active in the powerplant."
+ --#TYPE "APC: A LVD Imminent alarm is active in the powerplant."
+ --#SUMMARY "A LVD Imminent alarm is active in the powerplant."
+ --#ARGUMENTS { }
+ --#SEVERITY WARNING
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 152
+
+dcLVDImminentAlarmCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: A LVD Imminent alarm is no longer active in the powerplant."
+ --#TYPE "APC: A LVD Imminent alarm is no longer active in the powerplant."
+ --#SUMMARY "A LVD Imminent alarm is no longer active in the powerplant."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 153
+
+dcFuseCBAlarm TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString }
+ DESCRIPTION
+ "WARNING: A Fuse/CB alarm is active in the DC power plant."
+ --#TYPE "APC: A Fuse/CB alarm alarm is active in the DC power plant."
+ --#SUMMARY "A Fuse/CB alarm is active in the DC power plant."
+ --#ARGUMENTS { }
+ --#SEVERITY WARNING
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 154
+
+dcFuseCBAlarmCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: A Fuse/CB alarm is no longer active in the DC power plant."
+ --#TYPE "APC: A Fuse/CB alarm is no longer active in the DC power plant."
+ --#SUMMARY "A Fuse/CB alarm is no longer active in the DC power plant."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 155
+
+dcBatteryTestFail TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString }
+ DESCRIPTION
+ "WARNING: A Battery Test failed in the DC power plant."
+ --#TYPE "APC: A Battery Test failed in the DC power plant."
+ --#SUMMARY "A Battery Test failed in the DC power plant."
+ --#ARGUMENTS { }
+ --#SEVERITY WARNING
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 156
+
+dcTemperatureAlarm TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString }
+ DESCRIPTION
+ "WARNING: A Temperature is active in the power plant."
+ --#TYPE "APC: A Temperature alarm is active in the power plant."
+ --#SUMMARY "A Temperature alarm is active in the power plant."
+ --#ARGUMENTS { }
+ --#SEVERITY WARNING
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 157
+
+dcTemperatureAlarmCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: A Temperature alarm is no longer active in the power plant."
+ --#TYPE "APC: A Temperature alarm is no longer active in the power plant."
+ --#SUMMARY "A Temperature alarm is no longer active in the power plant."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 158
+
+dcHumidityAlarm TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString }
+ DESCRIPTION
+ "WARNING: A Humidity alarm is active in the DC power plant."
+ --#TYPE "APC: A Humidity alarm is active in the DC power plant."
+ --#SUMMARY "A Humidity alarm is active in the DC power plant."
+ --#ARGUMENTS { }
+ --#SEVERITY WARNING
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 159
+
+dcHumidityAlarmCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: A Humidity alarm is no longer active in the DC power plant."
+ --#TYPE "APC: A Humidity alarm is no longer active in the DC power plant."
+ --#SUMMARY "A Humidity alarm is no longer active in the DC power plant."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 160
+
+dcBBCommunicationEstablished TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: Power plant bridging board communications established."
+ --#TYPE "APC: Power plant bridging board communications established."
+ --#SUMMARY "Power plant bridging board communications established."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 161
+
+dcBBCommunicationLost TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString }
+ DESCRIPTION
+ "SEVERE: Power plant bridging board communications lost."
+ --#TYPE "APC: Power plant bridging board communications lost."
+ --#SUMMARY "Power plant bridging board communications lost."
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 162
+
+iemHighTempThresholdViolation TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { iemStatusProbeCurrentTemp, iemStatusProbeTempUnits, iemStatusProbeNumber,
+ iemStatusProbeName, mtrapargsString }
+ DESCRIPTION
+ "SEVERE: High temperature threshold violated on Integrated
+ Environmental Monitor probe. The first variable is the
+ current temperature. The second variable is the temperature
+ scale. The third variable is the probe number. The fourth
+ variable is the probe name."
+ --#TYPE "APC IEM: High temperature threshold violation."
+ --#SUMMARY "High temperature threshold violation."
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 163
+
+iemHighTempThresholdViolationCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { iemStatusProbeNumber, iemStatusProbeName, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: High temperature threshold violated on Integrated
+ Environmental Monitor probe has been cleared. The first variable
+ is the probe number. The second variable is the probe name."
+ --#TYPE "APC IEM: High temperature threshold violation cleared."
+ --#SUMMARY "High temperature threshold violation has been cleared."
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 164
+
+iemLowTempThresholdViolation TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { iemStatusProbeCurrentTemp, iemStatusProbeTempUnits, iemStatusProbeNumber,
+ iemStatusProbeName, mtrapargsString }
+ DESCRIPTION
+ "SEVERE: Low temperature threshold violated on integrated
+ probe. The first variable is the current temperature. The
+ second variable is the temperature scale. The third
+ variable is the probe number. The fourth variable is the
+ probe name."
+ --#TYPE "APC IEM: Low temperature threshold violation."
+ --#SUMMARY "Low temperature threshold violation."
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 165
+
+iemLowTempThresholdViolationCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { iemStatusProbeNumber, iemStatusProbeName, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: Low temperature threshold violated on integrated
+ probe has been cleared. The first variable is the probe number.
+ The second variable is the probe name."
+ --#TYPE "APC IEM: Low temperature threshold violation cleared."
+ --#SUMMARY "Low temperature threshold violation has been cleared."
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 166
+
+iemHighHumidThresholdViolation TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { iemStatusProbeCurrentHumid, iemStatusProbeNumber, iemStatusProbeName,
+ mtrapargsString }
+ DESCRIPTION
+ "SEVERE: High humidity threshold violated on integrated
+ probe. The first variable is the current humidity. The
+ second variable is the probe number. The third variable
+ is the probe name."
+ --#TYPE "APC IEM: High humidity threshold violation."
+ --#SUMMARY "High humidity threshold violation."
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 167
+
+iemHighHumidThresholdViolationCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { iemStatusProbeNumber, iemStatusProbeName, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: High humidity threshold violated on integrated
+ probe cleared. The first variable is the probe number. The second
+ variable is the probe name."
+ --#TYPE "APC IEM: High humidity threshold violation cleared."
+ --#SUMMARY "High humidity threshold violation has been cleared."
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 168
+
+iemLowHumidThresholdViolation TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { iemStatusProbeCurrentHumid, iemStatusProbeNumber, iemStatusProbeName,
+ mtrapargsString }
+ DESCRIPTION
+ "SEVERE: Low humidity threshold violated on integrated
+ probe. The first variable is the current humidity. The
+ second variable is the probe number. The third variable
+ is the probe name."
+ --#TYPE "APC IEM: Low humidity threshold violation."
+ --#SUMMARY "Low humidity threshold violation."
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 169
+
+iemLowHumidThresholdViolationCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { iemStatusProbeNumber, iemStatusProbeName, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: Low humidity threshold violated on integrated
+ probe cleared. The first variable is the probe number. The second
+ variable is the probe name."
+ --#TYPE "APC IEM: Low humidity threshold violation cleared."
+ --#SUMMARY "Low humidity threshold violation has been cleared."
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 170
+
+iemProbeDisconnected TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString }
+ DESCRIPTION
+ "WARNING: The temperature/humidity probe on the Integrated
+ Environmental Monitor has been disconnected. This trap is
+ generated when a probe that has been in communication with
+ the Environmental Monitor has been disconnected or can no
+ longer communicate."
+ --#TYPE "APC IEM: Probe disconnected."
+ --#SUMMARY "Probe has been disconnected."
+ --#SEVERITY WARNING
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 171
+
+iemProbeConnected TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: The temperature/humidity probe on the Integrated
+ Environmental Monitor has been connected. This trap is generated
+ when the Environmental Monitor establishes communication with a
+ probe that had previously not been connected."
+ --#TYPE "APC IEM: Probe Connected."
+ --#SUMMARY "Probe has been connected."
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 172
+
+iemContactFault TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { iemStatusContactNumber, iemStatusContactName, mtrapargsString }
+ DESCRIPTION
+ "SEVERE: There is a contact fault on the Integrated
+ Environmental Monitor. The first argument is the number
+ of the contact. The second argument is the name of the
+ contact."
+ --#TYPE "APC IEM: Contact fault."
+ --#SUMMARY "Contact fault."
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 173
+
+iemContactFaultCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { iemStatusContactNumber, iemStatusContactName, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: The contact fault on the Integrated
+ Environmental Monitor has been cleared. The first
+ argument is the number of the contact. The second
+ argument is the name of the contact."
+ --#TYPE "APC IEM: Contact fault."
+ --#SUMMARY "Contact fault cleared."
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 174
+
+iemRelayFault TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { iemStatusRelayNumber, iemStatusRelayName, mtrapargsString02, mtrapargsString }
+ DESCRIPTION
+ "SEVERE: The output relay on the Integrated Environmental
+ Monitor has switched to the fault state. The first
+ argument is the number of the output relay. The second
+ argument is the name of the output relay. The third
+ argument is the event that caused the fault."
+ --#TYPE "APC IEM: Output relay fault."
+ --#SUMMARY "Output relay has faulted."
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 175
+
+iemRelayFaultCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { iemStatusRelayNumber, iemStatusRelayName, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: The fault condition on the output relay on the
+ Integrated Environmental Monitor has cleared. The first
+ argument is the number of the output relay. The second
+ argument is the name of the output relay."
+ --#TYPE "APC IEM: Output relay fault condition cleared."
+ --#SUMMARY "Output relay fault cleared."
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 176
+
+bmBatManCommEstab TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsInteger, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: Serial Communications Established with Battery Manager."
+ --#TYPE "BatMan : Communications Established."
+ --#SUMMARY "Communications Established."
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 177
+
+bmBatManCommLost TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsInteger, mtrapargsString }
+ DESCRIPTION
+ "SEVERE: Serial Communications Lost with Battery Manager."
+ --#TYPE "BatMan : Communications Lost."
+ --#SUMMARY "Communications Lost."
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 178
+
+bmBatManKneeAlarm TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsInteger, mtrapargsString }
+ DESCRIPTION
+ "SEVERE: Battery Voltage Knee Threshold Alarm Detected."
+ --#TYPE "BatMan : Knee Alarm Detected."
+ --#SUMMARY "Knee Alarm Detected."
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 179
+
+bmBatManKneeAlarmCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsInteger, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: Battery Voltage Knee Threshold Alarm Cleared."
+ --#TYPE "BatMan : Knee Alarm Cleared."
+ --#SUMMARY "Knee Alarm Cleared."
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 180
+
+bmBatManChargerAlarm TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsInteger, mtrapargsString }
+ DESCRIPTION
+ "WARNING: Charger Alarm Detected."
+ --#TYPE "BatMan : Charger Alarm Detected."
+ --#SUMMARY "Charger Alarm Detected."
+ --#SEVERITY WARNING
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 181
+
+bmBatManChargerAlarmCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsInteger, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: Charger Alarm Cleared."
+ --#TYPE "BatMan : Charger Alarm Cleared."
+ --#SUMMARY "Charger Alarm Cleared."
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 182
+
+bmBatManBatteryAlarm TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsInteger, mtrapargsString }
+ DESCRIPTION
+ "WARNING: Battery Alarm Detected."
+ --#TYPE "BatMan : Battery Alarm Detected."
+ --#SUMMARY "Battery Alarm Detected."
+ --#SEVERITY WARNING
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 183
+
+bmBatManBatteryAlarmCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsInteger, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: Battery Alarm Cleared."
+ --#TYPE "BatMan : Battery Alarm Cleared."
+ --#SUMMARY "Battery Alarm Cleared."
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 184
+
+bmBatManEnvironmentAlarm TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsInteger, mtrapargsString }
+ DESCRIPTION
+ "WARNING: Environment Alarm Detected."
+ --#TYPE "BatMan : Environment Alarm Detected."
+ --#SUMMARY "Environment Alarm Detected."
+ --#SEVERITY WARNING
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 185
+
+bmBatManEnvironmentAlarmCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsInteger, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: Environment Alarm Cleared."
+ --#TYPE "BatMan : Environment Alarm Cleared."
+ --#SUMMARY "Environment Alarm Cleared."
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 186
+
+bmBatManMaintenanceAlarm TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsInteger, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: Maintenance Alarm Detected."
+ --#TYPE "BatMan : Maintenance Due Alarm Detected."
+ --#SUMMARY "Maintenance Due Alarm Detected."
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 187
+
+bmBatManMaintenanceAlarmCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsInteger, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: Maintenance Alarm Cleared."
+ --#TYPE "BatMan : Maintenance Due Alarm Cleared."
+ --#SUMMARY "Maintenance Due Alarm Cleared."
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 188
+
+pduCommunicationEstablished TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString03, mtrapargsString02, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: Communication Established.
+ The first argument is the serial number.
+ The second argument is the device name."
+ --#TYPE "APC PDU: Communication Established."
+ --#SUMMARY "Communication Established."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 189
+
+pduCommunicationLost TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString03, mtrapargsString02, mtrapargsString }
+ DESCRIPTION
+ "SEVERE: Communication Lost.
+ The first argument is the serial number.
+ The second argument is the device name."
+ --#TYPE "APC PDU: Communication Lost."
+ --#SUMMARY "Communication Lost."
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 190
+
+pduUtilityLineUndervoltage TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString03, mtrapargsString02, mtrapargsInteger, mtrapargsString }
+ DESCRIPTION
+ "SEVERE: Utility Line Undervoltage.
+ The first argument is the serial number.
+ The second argument is the device name.
+ The third argument is the phase number."
+ --#TYPE "APC PDU: Utility Line Undervoltage."
+ --#SUMMARY "Utility Line Undervoltage."
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 191
+
+pduUtilityLineUndervoltageCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString03, mtrapargsString02, mtrapargsInteger, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: Utility Line Undervoltage Cleared.
+ The first argument is the serial number.
+ The second argument is the device name.
+ The third argument is the phase number."
+ --#TYPE "APC PDU: Utility Line Undervoltage Cleared."
+ --#SUMMARY "Utility Line Undervoltage Cleared."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 192
+
+pduUtilityLineOvervoltage TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString03, mtrapargsString02, mtrapargsInteger, mtrapargsString }
+ DESCRIPTION
+ "SEVERE: Utility Line Overvoltage.
+ The first argument is the serial number.
+ The second argument is the device name.
+ The third argument is the phase number."
+ --#TYPE "APC PDU: Utility Line Overvoltage."
+ --#SUMMARY "Utility Line Overvoltage."
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 193
+
+pduUtilityLineOvervoltageCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString03, mtrapargsString02, mtrapargsInteger, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: Utility Line Overvoltage Cleared.
+ The first argument is the serial number.
+ The second argument is the device name.
+ The third argument is the phase number."
+ --#TYPE "APC PDU: Utility Line Overvoltage Cleared."
+ --#SUMMARY "Utility Line Overvoltage Cleared."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 194
+
+pduGroundOvercurrent TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString03, mtrapargsString02, mtrapargsString }
+ DESCRIPTION
+ "SEVERE: Ground Overcurrent.
+ The first argument is the serial number.
+ The second argument is the device name."
+ --#TYPE "APC PDU: Ground Overcurrent."
+ --#SUMMARY "Ground Overcurrent."
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 195
+
+pduGroundOvercurrentCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString03, mtrapargsString02, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: Ground Overcurrent Cleared.
+ The first argument is the serial number.
+ The second argument is the device name."
+ --#TYPE "APC PDU: Ground Overcurrent Cleared."
+ --#SUMMARY "Ground Overcurrent Cleared."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 196
+
+pduCircuitPanelInputUndervoltage TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString03, mtrapargsString02, mtrapargsInteger, mtrapargsString }
+ DESCRIPTION
+ "SEVERE: Circuit Panel Input Undervoltage.
+ The first argument is the serial number.
+ The second argument is the device name.
+ The third argument is the phase number."
+ --#TYPE "APC PDU: Circuit Panel Input Undervoltage."
+ --#SUMMARY "Circuit Panel Input Undervoltage."
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 197
+
+pduCircuitPanelInputUndervoltageCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString03, mtrapargsString02, mtrapargsInteger, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: Circuit Panel Input Undervoltage Cleared.
+ The first argument is the serial number.
+ The second argument is the device name.
+ The third argument is the phase number."
+ --#TYPE "APC PDU: Circuit Panel Input Undervoltage Cleared."
+ --#SUMMARY "Circuit Panel Input Undervoltage Cleared."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 198
+
+pduCircuitPanelInputOvervoltage TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString03, mtrapargsString02, mtrapargsInteger, mtrapargsString }
+ DESCRIPTION
+ "SEVERE: Circuit Panel Input Overvoltage.
+ The first argument is the serial number.
+ The second argument is the device name.
+ The third argument is the phase number."
+ --#TYPE "APC PDU: Circuit Panel Input Overvoltage."
+ --#SUMMARY "Circuit Panel Input Overvoltage."
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 199
+
+pduCircuitPanelInputOvervoltageCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString03, mtrapargsString02, mtrapargsInteger, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: Circuit Panel Input Overvoltage Cleared.
+ The first argument is the serial number.
+ The second argument is the device name.
+ The third argument is the phase number."
+ --#TYPE "APC PDU: Circuit Panel Input Overvoltage Cleared."
+ --#SUMMARY "Circuit Panel Input Overvoltage Cleared."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 200
+
+pduCircuitPanelInputUndercurrent TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString03, mtrapargsString02, mtrapargsInteger, mtrapargsString }
+ DESCRIPTION
+ "SEVERE: Circuit Panel Input Undercurrent.
+ The first argument is the serial number.
+ The second argument is the device name.
+ The third argument is the phase number."
+ --#TYPE "APC PDU: Circuit Panel Input Undercurrent."
+ --#SUMMARY "Circuit Panel Input Undercurrent."
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 201
+
+pduCircuitPanelInputUndercurrentCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString03, mtrapargsString02, mtrapargsInteger, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: Circuit Panel Input Undercurrent Cleared.
+ The first argument is the serial number.
+ The second argument is the device name.
+ The third argument is the phase number."
+ --#TYPE "APC PDU: Circuit Panel Input Undercurrent Cleared."
+ --#SUMMARY "Circuit Panel Input Undercurrent Cleared."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 202
+
+pduCircuitPanelInputOvercurrent TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString03, mtrapargsString02, mtrapargsInteger, mtrapargsString }
+ DESCRIPTION
+ "SEVERE: Circuit Panel Input Overcurrent.
+ The first argument is the serial number.
+ The second argument is the device name.
+ The third argument is the phase number."
+ --#TYPE "APC PDU: Circuit Panel Input Overcurrent."
+ --#SUMMARY "Circuit Panel Input Overcurrent."
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 203
+
+pduCircuitPanelInputOvercurrentCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString03, mtrapargsString02, mtrapargsInteger, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: Circuit Panel Input Overcurrent Cleared.
+ The first argument is the serial number.
+ The second argument is the device name.
+ The third argument is the phase number."
+ --#TYPE "APC PDU: Circuit Panel Input Overcurrent Cleared."
+ --#SUMMARY "Circuit Panel Input Overcurrent Cleared."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 204
+
+pduCircuitPanelFrequencyOutOfRange TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString03, mtrapargsString02, mtrapargsString }
+ DESCRIPTION
+ "SEVERE: Circuit Panel Input Frequency Out Of Range.
+ The first argument is the serial number.
+ The second argument is the device name."
+ --#TYPE "APC PDU: Circuit Panel Input Frequency Out Of Range."
+ --#SUMMARY "Circuit Panel Input Frequency Out Of Range."
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 205
+
+pduCircuitPanelFrequencyOutofRangeCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString03, mtrapargsString02, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: Circuit Panel Input Frequency No Longer Out Of Range.
+ The first argument is the serial number.
+ The second argument is the device name."
+ --#TYPE "APC PDU: Circuit Panel Input Frequency No Longer Out Of Range."
+ --#SUMMARY "Circuit Panel Input Frequency No Longer Out Of Range."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 206
+
+pduCircuitPanelNeutralOvercurrent TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString03, mtrapargsString02, mtrapargsString }
+ DESCRIPTION
+ "SEVERE: Circuit Panel Input Neutral Overcurrent.
+ The first argument is the serial number.
+ The second argument is the device name."
+ --#TYPE "APC PDU: Circuit Panel Input Neutral Overcurrent."
+ --#SUMMARY "Circuit Panel Input Neutral Overcurrent."
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 207
+
+pduCircuitPanelNeutralOvercurrentCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString03, mtrapargsString02, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: Circuit Panel Input Neutral Overcurrent Cleared.
+ The first argument is the serial number.
+ The second argument is the device name."
+ --#TYPE "APC PDU: Circuit Panel Input Neutral Overcurrent Cleared."
+ --#SUMMARY "Circuit Panel Input Neutral Overcurrent Cleared."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 208
+
+pduSystemOff TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString03, mtrapargsString02, mtrapargsString }
+ DESCRIPTION
+ "SEVERE: PDU System Off.
+ The first argument is the serial number.
+ The second argument is the device name."
+ --#TYPE "APC PDU: System Off."
+ --#SUMMARY "PDU System Off."
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 209
+
+pduOnBatteryMode TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString03, mtrapargsString02, mtrapargsString }
+ DESCRIPTION
+ "SEVERE: PDU is in On Battery Mode.
+ The first argument is the serial number.
+ The second argument is the device name."
+ --#TYPE "APC PDU: On Battery Mode."
+ --#SUMMARY "PDU is in On Battery Mode."
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 210
+
+pduMaintenanceBypassMode TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString03, mtrapargsString02, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: PDU is in Maintenance Bypass Mode.
+ The first argument is the serial number.
+ The second argument is the device name."
+ --#TYPE "APC PDU: Maintenance Bypass Mode."
+ --#SUMMARY "PDU is in Maintenance Bypass Mode."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 211
+
+pduAtypicalBypassMode TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString03, mtrapargsString02, mtrapargsString }
+ DESCRIPTION
+ "WARNING: PDU is in Atypical Bypass Mode.
+ The first argument is the serial number.
+ The second argument is the device name."
+ --#TYPE "APC PDU: Atypical Bypass Mode."
+ --#SUMMARY "PDU is in Atypical Bypass Mode."
+ --#ARGUMENTS { }
+ --#SEVERITY WARNING
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 212
+
+pduNoPanelFeedMode TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString03, mtrapargsString02, mtrapargsString }
+ DESCRIPTION
+ "SEVERE: PDU is in No Panel Feed Mode.
+ The first argument is the serial number.
+ The second argument is the device name."
+ --#TYPE "APC PDU: No Panel Feed Mode."
+ --#SUMMARY "PDU is in No Panel Feed Mode."
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 213
+
+pduUpsOperationMode TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString03, mtrapargsString02, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: PDU is in Ups Operation Mode.
+ The first argument is the serial number.
+ The second argument is the device name."
+ --#TYPE "APC PDU: Ups Operation Mode."
+ --#SUMMARY "PDU is in Ups Operation Mode."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 214
+
+pduForcedBypassMode TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString03, mtrapargsString02, mtrapargsString }
+ DESCRIPTION
+ "WARNING: PDU is in Forced Bypass Mode.
+ The first argument is the serial number.
+ The second argument is the device name."
+ --#TYPE "APC PDU: Forced Bypass Mode."
+ --#SUMMARY "PDU is in Forced Bypass Mode."
+ --#ARGUMENTS { }
+ --#SEVERITY WARNING
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 215
+
+pduInputTransformerOverTemperature TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString03, mtrapargsString02, mtrapargsString }
+ DESCRIPTION
+ "SEVERE: Input Transformer Over Temperature.
+ The first argument is the serial number.
+ The second argument is the device name."
+ --#TYPE "APC PDU: Input Transformer Over Temperature."
+ --#SUMMARY "Input Transformer Over Temperature."
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 216
+
+pduInputTransformerOverTemperatureCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString03, mtrapargsString02, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: Input Transformer Over Temperature Cleared.
+ The first argument is the serial number.
+ The second argument is the device name."
+ --#TYPE "APC PDU: Input Transformer Over Temperature Cleared."
+ --#SUMMARY "Input Transformer Over Temperature Cleared."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 217
+
+pduUPSInputVoltageLost TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString03, mtrapargsString02, mtrapargsInteger, mtrapargsString }
+ DESCRIPTION
+ "SEVERE: UPS Input Voltage phase-N Lost.
+ The first argument is the serial number.
+ The second argument is the device name.
+ The third argument is the phase number."
+ --#TYPE "APC PDU: UPS Input Voltage phase-N Lost."
+ --#SUMMARY "UPS Input Voltage phase-N Lost."
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 218
+
+pduUPSInputVoltageRestored TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString03, mtrapargsString02, mtrapargsInteger, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: UPS Input Voltage phase-N Restored.
+ The first argument is the serial number.
+ The second argument is the device name.
+ The third argument is the phase number."
+ --#TYPE "APC PDU: UPS Input Voltage phase-N Restored."
+ --#SUMMARY "UPS Input Voltage phase-N Restored."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 219
+
+pduContactFault TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString03, mtrapargsString02, mtrapargsInteger, mtrapargsString }
+ DESCRIPTION
+ "SEVERE: A contact closure in the PDU is in an abnormal position.
+ The first argument is the serial number.
+ The second argument is the device name.
+ The third argument is the number of the contact."
+ --#TYPE "APC PDU: Contact Abnormal."
+ --#SUMMARY "Contact Abnormal."
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 220
+
+pduContactFaultCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString03, mtrapargsString02, mtrapargsInteger, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: A contact closure in the PDU is in a normal position.
+ The first argument is the serial number.
+ The second argument is the device name.
+ The third argument is the number of the contact."
+ --#TYPE "APC PDU: Contact Normal."
+ --#SUMMARY "Contact Normal."
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 221
+
+rPDUBankPhaseLowLoad TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { rPDUIdentSerialNumber, rPDUIdentName,
+ rPDULoadStatusBankNumber, rPDULoadStatusPhaseNumber, mtrapargsString }
+ DESCRIPTION
+ "WARNING: A bank or phase on the Rack PDU has violated the low load threshold.
+ The first argument is the serial number.
+ The second argument is the device name.
+ The third argument is the bank number (0 if this is phase data).
+ The fourth argument is the phase number (0 if this is bank data)."
+ --#TYPE "APC Rack PDU: Violation of bank or phase low load threshold."
+ --#SUMMARY "A bank or phase on the Rack PDU has violated the low load threshold."
+ --#ARGUMENTS { }
+ --#SEVERITY WARNING
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 222
+
+rPDUBankPhaseLowLoadCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { rPDUIdentSerialNumber, rPDUIdentName,
+ rPDULoadStatusBankNumber, rPDULoadStatusPhaseNumber, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: The bank or phase low load condition on a Rack PDU has been
+ cleared.
+ The first argument is the serial number.
+ The second argument is the device name.
+ The third argument is the bank number (0 if this is phase data).
+ The fourth argument is the phase number (0 if this is bank data)."
+ --#TYPE "APC Rack PDU: Bank or phase low load condition cleared."
+ --#SUMMARY "The bank or phase low load condition on a Rack PDU has been cleared."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 223
+
+rPDUBankPhaseNearOverload TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { rPDUIdentSerialNumber, rPDUIdentName,
+ rPDULoadStatusBankNumber, rPDULoadStatusPhaseNumber, mtrapargsString }
+ DESCRIPTION
+ "WARNING: A bank or phase of the Rack PDU is near an overload condition.
+ The first argument is the serial number.
+ The second argument is the device name.
+ The third argument is the bank number (0 if this is phase data).
+ The fourth argument is the phase number (0 if this is bank data)."
+ --#TYPE "APC Rack PDU: Bank or phase near an overload condition."
+ --#SUMMARY "A bank or phase of the Rack PDU is near an overload condition."
+ --#ARGUMENTS { }
+ --#SEVERITY WARNING
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 224
+
+rPDUBankPhaseNearOverloadCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { rPDUIdentSerialNumber, rPDUIdentName,
+ rPDULoadStatusBankNumber, rPDULoadStatusPhaseNumber, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: The bank or phase near overload condition on a Rack PDU has
+ been cleared.
+ The first argument is the serial number.
+ The second argument is the device name.
+ The third argument is the bank number (0 if this is phase data).
+ The fourth argument is the phase number (0 if this is bank data)."
+ --#TYPE "APC Rack PDU: Bank or phase near overload condition has cleared."
+ --#SUMMARY "Rack PDU bank or phase near overload condition has cleared."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 225
+
+rPDUBankPhaseOverload TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { rPDUIdentSerialNumber, rPDUIdentName,
+ rPDULoadStatusBankNumber, rPDULoadStatusPhaseNumber, mtrapargsString }
+ DESCRIPTION
+ "SEVERE: A bank or phase of the Rack PDU is in an overload condition.
+ The first argument is the serial number.
+ The second argument is the device name.
+ The third argument is the phase number.
+ The third argument is the bank number (0 if this is phase data).
+ The fourth argument is the phase number (0 if this is bank data)."
+ --#TYPE "APC Rack PDU: Bank or phase overload condition."
+ --#SUMMARY "A bank or phase of the Rack PDU is in an overload condition."
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 226
+
+rPDUBankPhaseOverloadCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { rPDUIdentSerialNumber, rPDUIdentName,
+ rPDULoadStatusBankNumber, rPDULoadStatusPhaseNumber, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: The bank or phase overload condition on a Rack PDU has been
+ cleared.
+ The first argument is the serial number.
+ The second argument is the device name.
+ The third argument is the bank number (0 if this is phase data).
+ The fourth argument is the phase number (0 if this is bank data)."
+ --#TYPE "APC Rack PDU: Bank or phase overload condition has cleared."
+ --#SUMMARY "The bank or phase overload condition on a Rack PDU has cleared."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 227
+
+aruDeviceConfigChange TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { emsIdentSerialNumber, emsIdentEMSName,
+ rARUStatusAruIndex, rARUStatusAruName, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: Remote ARU Device Configurtion change.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the ARU number.
+ The fourth argument is the ARU name."
+ --#TYPE "APC ARU: ARU Device configuration change."
+ --#SUMMARY "ARU device configuration change."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 228
+
+rmPDUCommunicationLost TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString03, mtrapargsString02, mtrapargsString }
+ DESCRIPTION
+ "SEVERE: Communication Lost.
+ The first argument is the serial number.
+ The second argument is the device name."
+ --#TYPE "APC RM PDU: Communication Lost."
+ --#SUMMARY "Communication Lost."
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 229
+
+emsCommunicationEstablished TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { emsIdentSerialNumber, emsIdentEMSName, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: Communication Established.
+ The first argument is the serial number.
+ The second argument is the device name."
+ --#TYPE "APC EMS: Communication Established."
+ --#SUMMARY "Communication Established."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 230
+
+emsCommunicationLost TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { emsIdentSerialNumber, emsIdentEMSName, mtrapargsString }
+ DESCRIPTION
+ "SEVERE: Communication Lost.
+ The first argument is the serial number.
+ The second argument is the device name."
+ --#TYPE "APC EMS: Communication Lost."
+ --#SUMMARY "Communication Lost."
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 231
+
+emsProbeConnected TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { emsIdentSerialNumber, emsIdentEMSName,
+ emsProbeStatusProbeIndex, emsProbeStatusProbeName, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: A probe has been connected to the EMS.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the probe number.
+ The fourth argument is the probe name."
+ --#TYPE "APC EMS: Probe Connected."
+ --#SUMMARY "Probe Connected."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 232
+
+emsProbeDisconnected TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { emsIdentSerialNumber, emsIdentEMSName,
+ emsProbeStatusProbeIndex, emsProbeStatusProbeName, mtrapargsString }
+ DESCRIPTION
+ "SEVERE: A probe has been disconnected from the EMS.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the probe number.
+ The fourth argument is the probe name."
+ --#TYPE "APC EMS: Probe Disconnected."
+ --#SUMMARY "Probe Disconnected."
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 233
+
+emsSensorConnected TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { emsIdentSerialNumber, emsIdentEMSName,
+ emsSensorStatusSensorIndex, emsSensorStatusSensorName, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: A sensor has been connected to the EMS.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the sensor number.
+ The fourth argument is the sensor name."
+ --#TYPE "APC EMS: Sensor Connected."
+ --#SUMMARY "Sensor Connected."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 234
+
+emsSensorDisconnected TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { emsIdentSerialNumber, emsIdentEMSName,
+ emsSensorStatusSensorIndex, emsSensorStatusSensorName, mtrapargsString }
+ DESCRIPTION
+ "SEVERE: A sensor has been disconnected from the EMS.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the sensor number.
+ The fourth argument is the sensor name."
+ --#TYPE "APC EMS: Sensor Disconnected."
+ --#SUMMARY "Sensor Disconnected."
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 235
+
+emsSensorFault TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { emsIdentSerialNumber, emsIdentEMSName,
+ emsSensorStatusSensorIndex, emsSensorStatusSensorName, mtrapargsString }
+ DESCRIPTION
+ "SEVERE: A EMS sensor is in the fault condition.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the sensor number.
+ The fourth argument is the sensor name."
+ --#TYPE "APC EMS: Sensor Fault."
+ --#SUMMARY "Sensor Fault."
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 236
+
+emsSensorFaultCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { emsIdentSerialNumber, emsIdentEMSName,
+ emsSensorStatusSensorIndex, emsSensorStatusSensorName, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: A EMS sensor fault condition has cleared.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the sensor number.
+ The fourth argument is the sensor name."
+ --#TYPE "APC EMS: Sensor Fault Cleared."
+ --#SUMMARY "Sensor Fault Cleared."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 237
+
+emsBeaconConnected TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { emsIdentSerialNumber, emsIdentEMSName, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: A beacon has been connected to the EMS.
+ The first argument is the host device serial number.
+ The second argument is the host device name."
+ --#TYPE "APC EMS: Beacon Connected."
+ --#SUMMARY "Beacon Connected."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 238
+
+emsBeaconDisconnected TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { emsIdentSerialNumber, emsIdentEMSName, mtrapargsString }
+ DESCRIPTION
+ "SEVERE: A beacon has been disconnected from the EMS.
+ The first argument is the host device serial number.
+ The second argument is the host device name."
+ --#TYPE "APC EMS: Beacon Disconnected."
+ --#SUMMARY "Beacon Disconnected."
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 239
+
+emsBeaconOn TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { emsIdentSerialNumber, emsIdentEMSName, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: A EMS beacon has gone on.
+ The first argument is the host device serial number.
+ The second argument is the host device name."
+ --#TYPE "APC EMS: Beacon On."
+ --#SUMMARY "Beacon On."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 240
+
+emsBeaconOff TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { emsIdentSerialNumber, emsIdentEMSName, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: A EMS beacon has gone off.
+ The first argument is the host device serial number.
+ The second argument is the host device name."
+ --#TYPE "APC EMS: Beacon Off."
+ --#SUMMARY "Beacon Off."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 241
+
+emsMajorAlarm TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { emsIdentSerialNumber, emsIdentEMSName, mtrapargsString }
+ DESCRIPTION
+ "SEVERE: A Major Alarm is present in the EMS.
+ The first argument is the EMS serial number.
+ The second argument is the EMS name."
+ --#TYPE "APC EMS: Major Alarm."
+ --#SUMMARY "Major Alarm."
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 242
+
+emsMajorAlarmCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { emsIdentSerialNumber, emsIdentEMSName, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: A Major Alarm condition has been cleared in the EMS.
+ The first argument is the EMS serial number.
+ The second argument is the EMS name."
+ --#TYPE "APC EMS: Major Alarm Cleared."
+ --#SUMMARY "Major Alarm Cleared."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 243
+
+emsMinorAlarm TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { emsIdentSerialNumber, emsIdentEMSName, mtrapargsString }
+ DESCRIPTION
+ "SEVERE: A Minor Alarm is present in the EMS.
+ The first argument is the EMS serial number.
+ The second argument is the EMS name."
+ --#TYPE "APC EMS: Minor Alarm."
+ --#SUMMARY "Minor Alarm."
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 244
+
+emsMinorAlarmCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { emsIdentSerialNumber, emsIdentEMSName, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: A Minor Alarm condition has been cleared in the EMS.
+ The first argument is the EMS serial number.
+ The second argument is the EMS name."
+ --#TYPE "APC EMS: Minor Alarm Cleared."
+ --#SUMMARY "Minor Alarm Cleared."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 245
+
+emsOutletStateAbnormal TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { emsIdentSerialNumber, emsIdentEMSName, emsOutletStatusOutletIndex, emsOutletStatusOutletName,
+ emsOutletStatusOutletState, emsOutletStatusOutletNormalState, mtrapargsString }
+ DESCRIPTION
+ "WARNING: An outlet on the EMS has changed to its abnormal state.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the outlet number.
+ The fourth argument is the outlet name.
+ The fifth argument is the current outlet state (1=ON, 2=OFF).
+ The sixth argument is the configured normal outlet state (1=ON, 2=OFF)."
+ --#TYPE "APC EMS: Outlet has changed to its abnormal state."
+ --#SUMMARY "Outlet has changed to its abnormal state."
+ --#ARGUMENTS { }
+ --#SEVERITY WARNING
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 246
+
+emsOutletStateNormal TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { emsIdentSerialNumber, emsIdentEMSName, emsOutletStatusOutletIndex, emsOutletStatusOutletName,
+ emsOutletStatusOutletState, emsOutletStatusOutletNormalState, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: An outlet on the EMS has changed to its normal state.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the outlet number.
+ The fourth argument is the outlet name.
+ The fifth argument is the current outlet state (1=ON, 2=OFF).
+ The sixth argument is the configured normal outlet state (1=ON, 2=OFF)."
+ --#TYPE "APC EMS: Outlet has changed to its normal state."
+ --#SUMMARY "Outlet has changed to its normal state."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 247
+
+emsInputContactStateAbnormal TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { emsIdentSerialNumber, emsIdentEMSName, emsInputContactStatusInputContactIndex,
+ emsInputContactStatusInputContactName, emsInputContactStatusInputContactState,
+ emsInputContactStatusInputContactNormalState, mtrapargsString }
+ DESCRIPTION
+ "WARNING: An input contact on the EMS has changed to its abnormal state.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the input contact number.
+ The fourth argument is the input contact name.
+ The fifth argument is the input contact state (1=CLOSED, 2=OPEN).
+ The sixth argument is the configured normal input contact state (1=CLOSED, 2=OPEN)."
+ --#TYPE "APC EMS: Input contact has changed to its abnormal state."
+ --#SUMMARY "Input contact has changed to its abnormal state."
+ --#ARGUMENTS { }
+ --#SEVERITY WARNING
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 248
+
+emsInputContactStateNormal TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { emsIdentSerialNumber, emsIdentEMSName, emsInputContactStatusInputContactIndex,
+ emsInputContactStatusInputContactName, emsInputContactStatusInputContactState,
+ emsInputContactStatusInputContactNormalState, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: An input contact on the EMS has changed to its normal state.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the input contact number.
+ The fourth argument is the input contact name.
+ The fifth argument is the input contact state (1=CLOSED, 2=OPEN).
+ The sixth argument is the configured normal input contact state (1=CLOSED, 2=OPEN)."
+ --#TYPE "APC EMS: Input contact has changed to its normal state."
+ --#SUMMARY "Input contact has changed to its normal state."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 249
+
+emsOutputRelayStateAbnormal TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { emsIdentSerialNumber, emsIdentEMSName, emsOutputRelayStatusOutputRelayIndex,
+ emsOutputRelayStatusOutputRelayName, emsOutputRelayStatusOutputRelayState,
+ emsOutputRelayStatusOutputRelayNormalState, mtrapargsString }
+ DESCRIPTION
+ "WARNING: An output relay on the EMS has changed to its abnormal state.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the output relay number.
+ The fourth argument is the output relay name.
+ The fifth argument is the current output relay state (1=CLOSED, 2=OPEN).
+ The sixth argument is the configured normal output relay state (1=CLOSED, 2=OPEN)."
+ --#TYPE "APC EMS: Output Relay has changed to its abnormal state."
+ --#SUMMARY "Output Relay has changed to its abnormal state."
+ --#ARGUMENTS { }
+ --#SEVERITY WARNING
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 250
+
+emsOutputRelayStateNormal TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { emsIdentSerialNumber, emsIdentEMSName, emsOutputRelayStatusOutputRelayIndex,
+ emsOutputRelayStatusOutputRelayName, emsOutputRelayStatusOutputRelayState,
+ emsOutputRelayStatusOutputRelayNormalState, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: An output relay on the EMS has changed to its normal state.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the output relay number.
+ The fourth argument is the output relay name.
+ The fifth argument is the current output relay state (1=CLOSED, 2=OPEN).
+ The sixth argument is the configured normal output relay state (1=CLOSED, 2=OPEN)."
+ --#TYPE "APC EMS: Output Relay has changed to its normal state."
+ --#SUMMARY "Output Relay has changed to its normal state."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 251
+
+emsDeviceConfigChange TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { emsIdentSerialNumber, emsIdentEMSName, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: A device configuration change has been made on the EMS.
+ The first argument is the EMS serial number.
+ The second argument is the EMS name."
+ --#TYPE "APC: A device configuration change on a EMS."
+ --#SUMMARY "A device configuration change has been made on a EMS."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 252
+
+envHighTempThresholdViolation TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { emsIdentSerialNumber, emsIdentEMSName, emsProbeStatusProbeTemperature, emsStatusSysTempUnits,
+ emsProbeStatusProbeIndex, emsProbeStatusProbeName, mtrapargsString }
+ DESCRIPTION
+ "SEVERE: High temperature threshold violated on the probe.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the current temperature.
+ The fourth argument is the temperature scale.
+ The fifth argument is the probe number.
+ The sixth argument is the probe name."
+ --#TYPE "APC ENV: High temperature threshold violation."
+ --#SUMMARY "High temperature threshold violation."
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 253
+
+envHighTempThresholdViolationCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { emsIdentSerialNumber, emsIdentEMSName, emsProbeStatusProbeTemperature, emsStatusSysTempUnits,
+ emsProbeStatusProbeIndex, emsProbeStatusProbeName, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: High temperature threshold violation cleared on the probe.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the current temperature.
+ The fourth argument is the temperature scale.
+ The fifth argument is the probe number.
+ The sixth argument is the probe name."
+ --#TYPE "APC ENV: High temperature threshold violation cleared."
+ --#SUMMARY "High temperature threshold violation cleared."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 254
+
+envLowTempThresholdViolation TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { emsIdentSerialNumber, emsIdentEMSName, emsProbeStatusProbeTemperature, emsStatusSysTempUnits,
+ emsProbeStatusProbeIndex, emsProbeStatusProbeName, mtrapargsString }
+ DESCRIPTION
+ "SEVERE: Low temperature threshold violated on the probe.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the current temperature.
+ The fourth argument is the temperature scale.
+ The fifth argument is the probe number.
+ The sixth argument is the probe name."
+ --#TYPE "APC ENV: Low temperature threshold violation."
+ --#SUMMARY "Low temperature threshold violation."
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 255
+
+envLowTempThresholdViolationCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { emsIdentSerialNumber, emsIdentEMSName, emsProbeStatusProbeTemperature, emsStatusSysTempUnits,
+ emsProbeStatusProbeIndex, emsProbeStatusProbeName, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: Low temperature threshold violation cleared on the probe.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the current temperature.
+ The fourth argument is the temperature scale.
+ The fifth argument is the probe number.
+ The sixth argument is the probe name."
+ --#TYPE "APC ENV: Low temperature threshold violation cleared."
+ --#SUMMARY "Low temperature threshold violation cleared."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 256
+
+envHighHumidityThresholdViolation TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { emsIdentSerialNumber, emsIdentEMSName, emsProbeStatusProbeHumidity,
+ emsProbeStatusProbeIndex, emsProbeStatusProbeName, mtrapargsString }
+ DESCRIPTION
+ "SEVERE: High humidity threshold violated on the probe.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the current humidity
+ The fourth argument is the probe number.
+ The fifth argument is the probe name."
+ --#TYPE "APC ENV: High humidity threshold violation."
+ --#SUMMARY "High humidity threshold violation."
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 257
+
+envHighHumidityThresholdViolationCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { emsIdentSerialNumber, emsIdentEMSName, emsProbeStatusProbeHumidity,
+ emsProbeStatusProbeIndex, emsProbeStatusProbeName, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: High humidity threshold violation cleared on the probe.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the current humidity.
+ The fourth argument is the probe number.
+ The fifth argument is the probe name."
+ --#TYPE "APC ENV: High humidity threshold violation cleared."
+ --#SUMMARY "High humidity threshold violation cleared."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 258
+
+envLowHumidityThresholdViolation TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { emsIdentSerialNumber, emsIdentEMSName, emsProbeStatusProbeHumidity,
+ emsProbeStatusProbeIndex, emsProbeStatusProbeName, mtrapargsString }
+ DESCRIPTION
+ "SEVERE: Low humidity threshold violated on the probe.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the current humidity
+ The fourth argument is the probe number.
+ The fifth argument is the probe name."
+ --#TYPE "APC ENV: Low humidity threshold violation."
+ --#SUMMARY "Low humidity threshold violation."
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 259
+
+envLowHumidityThresholdViolationCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { emsIdentSerialNumber, emsIdentEMSName, emsProbeStatusProbeHumidity,
+ emsProbeStatusProbeIndex, emsProbeStatusProbeName, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: Low humidity threshold violation cleared on the probe.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the current humidity.
+ The fourth argument is the probe number.
+ The fifth argument is the probe name."
+ --#TYPE "APC ENV: Low humidity threshold violation cleared."
+ --#SUMMARY "Low humidity threshold violation cleared."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 260
+
+
+-- Switched and Metered Rack PDU Traps
+
+rPDUCommunicationEstablished TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { rPDUIdentSerialNumber, rPDUIdentName, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: Communication with a Rack PDU has been established.
+ The first argument is the serial number.
+ The second argument is the device name."
+ --#TYPE "APC Rack PDU: Communication established."
+ --#SUMMARY "Communication with a Rack PDU established."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 266
+
+rPDUCommunicationLost TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { rPDUIdentSerialNumber, rPDUIdentName, mtrapargsString }
+ DESCRIPTION
+ "SEVERE: Communication with a Rack PDU has been lost.
+ The first argument is the serial number.
+ The second argument is the device name."
+ --#TYPE "APC Rack PDU: Communication lost."
+ --#SUMMARY "Communication with a Rack PDU has been lost."
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 267
+
+rPDUOutletOn TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { rPDUIdentSerialNumber, rPDUIdentName,
+ rPDUOutletControlIndex, rPDUOutletControlOutletName,
+ mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: An outlet on a Switched Rack PDU has turned on.
+ The first argument is the serial number.
+ The second argument is the device name.
+ The third argument is the outlet index number.
+ The fourth argument is the outlet name."
+ --#TYPE "APC Switched Rack PDU: An outlet has turned on."
+ --#SUMMARY "An outlet on a Switched Rack PDU has turned on."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 268
+
+rPDUOutletOff TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { rPDUIdentSerialNumber, rPDUIdentName,
+ rPDUOutletControlIndex, rPDUOutletControlOutletName,
+ mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: An outlet on a Switched Rack PDU has turned off.
+ The first argument is the serial number.
+ The second argument is the device name.
+ The third argument is the outlet index number.
+ The fourth argument is the outlet name."
+ --#TYPE "APC Switched Rack PDU: An outlet has turned off."
+ --#SUMMARY "An outlet on a Switched Rack PDU has turned off."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 269
+
+rPDUDeviceConfigChange TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { rPDUIdentSerialNumber, rPDUIdentName, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: A device configuration change has been made on a
+ Rack PDU.
+ The first argument is the serial number.
+ The second argument is the device name."
+ --#TYPE "APC Rack PDU: Device configuration change made."
+ --#SUMMARY "Device configuration change has been made on a Rack PDU."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 270
+
+rPDUOutletConfigChange TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { rPDUIdentSerialNumber, rPDUIdentName,
+ rPDUOutletControlIndex, rPDUOutletControlOutletName,
+ mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: An outlet configuration change has been made on a
+ Switched Rack PDU.
+ The first argument is the serial number.
+ The second argument is the device name.
+ The third argument is the outlet index number.
+ The fourth argument is the outlet name."
+ --#TYPE "APC Switched Rack PDU: Outlet configuration change made."
+ --#SUMMARY "Outlet configuration change has been made on a Switched Rack PDU."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 271
+
+rPDULowLoad TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { rPDUIdentSerialNumber, rPDUIdentName,
+ rPDULoadStatusPhaseNumber, mtrapargsString }
+ DESCRIPTION
+ "WARNING: A Rack PDU has violated the low load threshold.
+ The first argument is the serial number.
+ The second argument is the device name.
+ The third argument is the phase number."
+ --#TYPE "APC Rack PDU: Violation of low load threshold."
+ --#SUMMARY "A Rack PDU has violated the low load threshold."
+ --#ARGUMENTS { }
+ --#SEVERITY WARNING
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 272
+
+rPDULowLoadCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { rPDUIdentSerialNumber, rPDUIdentName,
+ rPDULoadStatusPhaseNumber, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: The low load condition on a Rack PDU has been
+ cleared.
+ The first argument is the serial number.
+ The second argument is the device name.
+ The third argument is the phase number."
+ --#TYPE "APC Rack PDU: Low load condition cleared."
+ --#SUMMARY "The low load condition on a Rack PDU has been cleared."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 273
+
+rPDUNearOverload TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { rPDUIdentSerialNumber, rPDUIdentName,
+ rPDULoadStatusPhaseNumber, mtrapargsString }
+ DESCRIPTION
+ "WARNING: A Rack PDU is near an overload condition.
+ The first argument is the serial number.
+ The second argument is the device name.
+ The third argument is the phase number."
+ --#TYPE "APC Rack PDU: Near an overload condition."
+ --#SUMMARY "A Rack PDU is near an overload condition."
+ --#ARGUMENTS { }
+ --#SEVERITY WARNING
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 274
+
+rPDUNearOverloadCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { rPDUIdentSerialNumber, rPDUIdentName,
+ rPDULoadStatusPhaseNumber, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: The near overload condition on a Rack PDU has
+ been cleared.
+ The first argument is the serial number.
+ The second argument is the device name.
+ The third argument is the phase number."
+ --#TYPE "APC Rack PDU: Near overload condition has cleared."
+ --#SUMMARY "Rack PDU near overload condition has cleared."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 275
+
+rPDUOverload TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { rPDUIdentSerialNumber, rPDUIdentName,
+ rPDULoadStatusPhaseNumber, mtrapargsString }
+ DESCRIPTION
+ "SEVERE: A Rack PDU is in an overload condition.
+ The first argument is the serial number.
+ The second argument is the device name.
+ The third argument is the phase number."
+ --#TYPE "APC Rack PDU: Overload condition."
+ --#SUMMARY "A Rack PDU is in an overload condition."
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 276
+
+rPDUOverloadCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { rPDUIdentSerialNumber, rPDUIdentName,
+ rPDULoadStatusPhaseNumber, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: The overload condition on a Rack PDU has been
+ cleared.
+ The first argument is the serial number.
+ The second argument is the device name.
+ The third argument is the phase number."
+ --#TYPE "APC Rack PDU: Overload condition has cleared."
+ --#SUMMARY "The overload condition on a Rack PDU has cleared."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 277
+
+rPDUPowerSupply1Fail TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { rPDUIdentSerialNumber, rPDUIdentName, mtrapargsString }
+ DESCRIPTION
+ "SEVERE: Power Supply 1 on Rack PDU is in FAIL state.
+ The first argument is the serial number.
+ The second argument is the device name."
+ --#TYPE "APC Rack PDU: Power Supply 1 is in FAIL state."
+ --#SUMMARY "Power Supply 1 on Rack PDU is in FAIL state."
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 278
+
+rPDUPowerSupply1Ok TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { rPDUIdentSerialNumber, rPDUIdentName, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: Power Supply 1 on Rack PDU is operating normally.
+ The first argument is the serial number.
+ The second argument is the device name."
+ --#TYPE "APC Rack PDU: Power Supply 1 is operating normally."
+ --#SUMMARY "Power Supply 1 on Rack PDU is operating normally."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 279
+
+rPDUPowerSupply2Fail TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { rPDUIdentSerialNumber, rPDUIdentName, mtrapargsString }
+ DESCRIPTION
+ "SEVERE: Power Supply 2 on Rack PDU is in FAIL state.
+ The first argument is the serial number.
+ The second argument is the device name."
+ --#TYPE "APC Rack PDU: Power Supply 2 is in FAIL state."
+ --#SUMMARY "Power Supply 2 on Rack PDU is in FAIL state."
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 280
+
+rPDUPowerSupply2Ok TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { rPDUIdentSerialNumber, rPDUIdentName, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: Power Supply 2 on Rack PDU is operating normally.
+ The first argument is the serial number.
+ The second argument is the device name."
+ --#TYPE "APC Rack PDU: Power Supply 2 is operating normally."
+ --#SUMMARY "Power Supply 2 on Rack PDU is operating normally."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 281
+
+rPDUPhaseConfigChange TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { rPDUIdentSerialNumber, rPDUIdentName,
+ rPDULoadPhaseConfigIndex, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: A phase configuration change has been made on a
+ Rack PDU.
+ The first argument is the serial number.
+ The second argument is the device name.
+ The third argument is the phase index number."
+ --#TYPE "APC Rack PDU: Phase configuration change made."
+ --#SUMMARY "Phase configuration change has been made on a Rack PDU."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 282
+
+rPDUCancelPendingCommand TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { rPDUIdentSerialNumber, rPDUIdentName,
+ rPDUOutletControlIndex, rPDUOutletControlOutletName,
+ mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: A cancel pending command has been made on a
+ Switched Rack PDU.
+ The first argument is the serial number.
+ The second argument is the device name.
+ The third argument is the outlet index number (0 indicates all outlets).
+ The fourth argument is the outlet name (or device name if all outlets)."
+ --#TYPE "APC Switched Rack PDU: Cancel Pending Command made."
+ --#SUMMARY "A Cancel Pending Command has been made on a Switched Rack PDU."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 283
+
+aruAlinkCommunicationEstablished TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { emsIdentSerialNumber, emsIdentEMSName,
+ rARUStatusAruIndex, rARUStatusAruName, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: Remote ARU Communication Established.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the ARU number.
+ The fourth argument is the ARU name."
+ --#TYPE "APC ARU: Communication Established."
+ --#SUMMARY "Communication Established."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 284
+
+aruAlinkCommunicationLost TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { emsIdentSerialNumber, emsIdentEMSName,
+ rARUStatusAruIndex, rARUStatusAruName, mtrapargsString }
+ DESCRIPTION
+ "SEVERE: Remote ARU Communication Lost.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the ARU number.
+ The fourth argument is the ARU name."
+ --#TYPE "APC ARU: Communication Lost."
+ --#SUMMARY "Communication Lost."
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 285
+
+aruFanFail TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { emsIdentSerialNumber, emsIdentEMSName,
+ rARUStatusAruIndex, rARUStatusAruName, mtrapargsString }
+ DESCRIPTION
+ "SEVERE: Remote ARU Fan Fail.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the ARU number.
+ The fourth argument is the ARU name."
+ --#TYPE "APC ARU: Fan Fail."
+ --#SUMMARY "Fan Fail."
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 286
+
+aruFanFailCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { emsIdentSerialNumber, emsIdentEMSName,
+ rARUStatusAruIndex, rARUStatusAruName, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: Remote ARU Fan Fail Cleared.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the ARU number.
+ The fourth argument is the ARU name."
+ --#TYPE "APC ARU: Fan Fail Cleared."
+ --#SUMMARY "Fan Fail Cleared."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 287
+
+aruSmokeAlarm TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { emsIdentSerialNumber, emsIdentEMSName,
+ rARUStatusAruIndex, rARUStatusAruName, mtrapargsString }
+ DESCRIPTION
+ "SEVERE: Remote ARU Smoke Alarm.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the ARU number.
+ The fourth argument is the ARU name."
+ --#TYPE "APC ARU: Smoke Alarm."
+ --#SUMMARY "Smoke Alarm."
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 288
+
+aruSmokeAlarmCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { emsIdentSerialNumber, emsIdentEMSName,
+ rARUStatusAruIndex, rARUStatusAruName, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: Remote ARU Smoke Alarm Cleared.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the ARU number.
+ The fourth argument is the ARU name."
+ --#TYPE "APC ARU: Smoke Alarm Cleared."
+ --#SUMMARY "Smoke Alarm Cleared."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 289
+
+aruHighTemperatureAlarm TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { emsIdentSerialNumber, emsIdentEMSName,
+ rARUStatusAruIndex, rARUStatusAruName, mtrapargsString }
+ DESCRIPTION
+ "SEVERE: Remote ARU High Temperature Alarm.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the ARU number.
+ The fourth argument is the ARU name."
+ --#TYPE "APC ARU: High Temperature Alarm."
+ --#SUMMARY "High Temperature Alarm."
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 290
+
+aruHighTemperatureAlarmCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { emsIdentSerialNumber, emsIdentEMSName,
+ rARUStatusAruIndex, rARUStatusAruName, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: Remote ARU High Temperature Alarm Cleared.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the ARU number.
+ The fourth argument is the ARU name."
+ --#TYPE "APC ARU: High Temperature Alarm Cleared."
+ --#SUMMARY "High Temperature Alarm Cleared."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 291
+
+aruExhaustTemperatureAlarm TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { emsIdentSerialNumber, emsIdentEMSName,
+ rARUStatusAruIndex, rARUStatusAruName, mtrapargsString }
+ DESCRIPTION
+ "SEVERE: Remote ARU Exhaust Temperature Alarm.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the ARU number.
+ The fourth argument is the ARU name."
+ --#TYPE "APC ARU: Exhaust Temperature Alarm."
+ --#SUMMARY "Exhaust Temperature Alarm."
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 292
+
+aruExhaustTemperatureAlarmCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { emsIdentSerialNumber, emsIdentEMSName,
+ rARUStatusAruIndex, rARUStatusAruName, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: Remote ARU Exhaust Temperature Alarm Cleared.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the ARU number.
+ The fourth argument is the ARU name."
+ --#TYPE "APC ARU: Exhaust Temperature Alarm Cleared."
+ --#SUMMARY "Exhaust Temperature Alarm Cleared."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 293
+
+envAlinkCommunicationEstablished TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { emsIdentSerialNumber, emsIdentEMSName,
+ emsProbeStatusProbeIndex, emsProbeStatusProbeName, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: Remote Probe Communication Established.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the probe number.
+ The fourth argument is the probe name."
+ --#TYPE "APC ENV: Communication Established."
+ --#SUMMARY "Communication Established."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 294
+
+envAlinkCommunicationLost TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { emsIdentSerialNumber, emsIdentEMSName,
+ emsProbeStatusProbeIndex, emsProbeStatusProbeName, mtrapargsString }
+ DESCRIPTION
+ "SEVERE: Remote Probe Communication Lost.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the probe number.
+ The fourth argument is the probe name."
+ --#TYPE "APC ENV: Communication Lost."
+ --#SUMMARY "Communication Lost."
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 295
+
+emsAlinkPowerOverload TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { emsIdentSerialNumber, emsIdentEMSName, mtrapargsString }
+ DESCRIPTION
+ "SEVERE: Alink Power Overload.
+ The first argument is the host device serial number.
+ The second argument is the host device name."
+ --#TYPE "APC EMS: Alink Power Overload."
+ --#SUMMARY "Alink Power Overload."
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 296
+
+emsAlinkPowerOverloadCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { emsIdentSerialNumber, emsIdentEMSName, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: Alink Power Overload Cleared.
+ The first argument is the host device serial number.
+ The second argument is the host device name."
+ --#TYPE "APC EMS: Alink Power Overload Cleared."
+ --#SUMMARY "Alink Power Overload Cleared."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 297
+
+upsOutletGroupTurnedOn TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { upsOutletGroupControlIndex, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: The specified Outlet Group turned on."
+ --#TYPE "APC UPS: Outlet Group turned on."
+ --#SUMMARY "Outlet Group turned on"
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 298
+
+upsOutletGroupTurnedOff TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { upsOutletGroupControlIndex, mtrapargsString }
+ DESCRIPTION
+ "WARNING: The specified Outlet Group turned off."
+ --#TYPE "APC UPS: Outlet Group turned off."
+ --#SUMMARY "Outlet Group turned off."
+ --#ARGUMENTS { }
+ --#SEVERITY WARNING
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 299
+
+smwCriticalCondition TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsGauge, mtrapargsString }
+ DESCRIPTION
+ "SEVERE: A Symmetra MW UPS critical condition has been detected.
+ The first variable is the fault condition."
+ --#TYPE "APC Symmetra MW UPS: A critical condition has been detected."
+ --#SUMMARY "A critical condition has been detected."
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 300
+
+smwCriticalConditionCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsGauge, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: A Symmetra MW UPS critical condition has been cleared.
+ The first variable is the fault condition."
+ --#TYPE "APC Symmetra MW UPS: A critical condition has been cleared."
+ --#SUMMARY "A critical condition has been cleared."
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 301
+
+smwWarningCondition TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsGauge, mtrapargsString }
+ DESCRIPTION
+ "WARNING: A Symmetra MW UPS warning condition has been detected.
+ The first variable is the fault condition."
+ --#TYPE "APC Symmetra MW UPS: A warning condition has been detected."
+ --#SUMMARY "A warning condition has been detected."
+ --#SEVERITY WARNING
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 302
+
+smwWarningConditionCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsGauge, mtrapargsString }
+ DESCRIPTION
+ "WARNING: A Symmetra MW UPS warning condition has been cleared.
+ The first variable is the fault condition."
+ --#TYPE "APC Symmetra MW UPS: A warning condition has been cleared."
+ --#SUMMARY "A warning condition has been cleared."
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 303
+
+smwInformationalCondition TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsGauge, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: A Symmetra MW UPS informational condition has been detected.
+ The first variable is the fault condition."
+ --#TYPE "APC Symmetra MW UPS: Informational condition detected."
+ --#SUMMARY "An informational condition has been detected."
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 304
+
+smwInformationalConditionCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsGauge, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: A Symmetra MW UPS informational condition has been cleared.
+ The first variable is the fault condition."
+ --#TYPE "APC Symmetra MW UPS: Informational condition cleared."
+ --#SUMMARY "An informational condition has been cleared."
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 305
+
+airCriticalCondition TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString02, mtrapargsInteger, mtrapargsString }
+ DESCRIPTION
+ "SEVERE: An Air critical condition was detected.
+ The first variable is the error condition text message.
+ The second variable is the error number."
+ --#TYPE "APC Air: A critical condition was detected. "
+ --#SUMMARY "A critical condition was detected. "
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 306
+
+airCriticalConditionCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString02, mtrapargsInteger, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: An Air critical condition was cleared.
+ The first variable is the error condition text message.
+ The second variable is the error number."
+ --#TYPE "APC Air: A critical condition was cleared. "
+ --#SUMMARY "A critical condition was cleared. "
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 307
+
+airWarningCondition TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString02, mtrapargsInteger, mtrapargsString }
+ DESCRIPTION
+ "WARNING: An Air warning condition was detected.
+ The first variable is the error condition text message.
+ The second variable is the error number."
+ --#TYPE "APC Air: A warning condition was detected. "
+ --#SUMMARY "A warning condition was detected. "
+ --#SEVERITY WARNING
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 308
+
+airWarningConditionCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString02, mtrapargsInteger, mtrapargsString }
+ DESCRIPTION
+ "WARNING: An Air warning condition was cleared.
+ The first variable is the error condition text message.
+ The second variable is the error number."
+ --#TYPE "APC Air: A warning condition was cleared. "
+ --#SUMMARY "A warning condition was cleared. "
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 309
+
+airInformationalCondition TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString02, mtrapargsInteger, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: An Air informational condition was detected.
+ The first variable is the error condition text message.
+ The second variable is the error number."
+ --#TYPE "APC Air: Informational condition detected. "
+ --#SUMMARY "An informational condition was detected. "
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 310
+
+airInformationalConditionCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString02, mtrapargsInteger, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: An Air informational condition was cleared.
+ The first variable is the error condition text message.
+ The second variable is the error number."
+ --#TYPE "APC Air: Informational condition was cleared. "
+ --#SUMMARY "An informational condition was cleared. "
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 311
+
+-- xPDU Traps (part 1)
+
+xPDUInputVoltageLowAlarm TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsInteger,
+ mtrapargsInteger02, mtrapargsInteger03, mtrapargsString }
+ DESCRIPTION
+ "WARNING: Three-phase input voltage to the device is outside the specified limits.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the phase
+ (1=L1-N, 2=L2-N, 3=L3-N, 4=unused, 5=L1-L2, 6=L2-L3, 7=L3-L1).
+ The fourth argument is the measured voltage in tenths of Volts.
+ The fifth argument is the threshold, in tenths of Volts, from which the alarm was generated."
+ --#TYPE "APC XPDU: Main input voltage out-of-range alarm."
+ --#SUMMARY "Input voltage is out-of-range."
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 312
+
+xPDUInputVoltageLowAlarmCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsInteger,
+ mtrapargsInteger02, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: Three-phase input voltage to the device is back within the specified limits.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the phase (1=L1-N, 2=L2-N, 3=L3-N, 4=unused, 5=L1-L2, 6=L2-L3, 7=L3-L1).
+ The fourth argument is the measured voltage in tenths of Volts."
+ --#TYPE "APC XPDU: Main input voltage back in range."
+ --#SUMMARY "Input voltage in range."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 313
+
+
+xPDUInputVoltageHighAlarm TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsInteger,
+ mtrapargsInteger02, mtrapargsInteger03, mtrapargsString }
+ DESCRIPTION
+ "WARNING: Three-phase input voltage to the device is outside the specified limits.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the phase
+ (1=L1-N, 2=L2-N, 3=L3-N, 4=unused, 5=L1-L2, 6=L2-L3, 7=L3-L1).
+ The fourth argument is the measured voltage in tenths of Volts.
+ The fifth argument is the threshold, in tenths of Volts, above which the alarm was generated."
+ --#TYPE "APC XPDU: Main input voltage out-of-range alarm."
+ --#SUMMARY "Input voltage is out-of-range."
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 314
+
+xPDUInputVoltageHighAlarmCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsInteger,
+ mtrapargsInteger02, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: Three-phase input voltage to the device is back within the specified limits.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the phase (1=L1-N, 2=L2-N, 3=L3-N, 4=unused, 5=L1-L2, 6=L2-L3, 7=L3-L1).
+ The fourth argument is the measured voltage in tenths of Volts."
+ --#TYPE "APC XPDU: Main input voltage back in range."
+ --#SUMMARY "Input voltage in range."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 315
+
+xPDUBypassVoltageLowAlarm TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsInteger,
+ mtrapargsInteger02, mtrapargsInteger03, mtrapargsString }
+ DESCRIPTION
+ "WARNING: Three-phase bypass input voltage to the device is outside the specified limits.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the phase (1=L1-N, 2=L2-N, 3=L3-N).
+ The fourth argument is the measured voltage in tenths of Volts.
+ The fifth argument is the threshold, in tenths of Volts, from which the alarm was generated."
+ --#TYPE "APC XPDU: Bypass input voltage out-of-range alarm."
+ --#SUMMARY "Bypass input voltage is out-of-range."
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 316
+
+xPDUBypassVoltageLowAlarmCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsInteger,
+ mtrapargsInteger02, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: Three-phase bypass input voltage to the device is back within the specified limits.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the phase (1=L1-N, 2=L2-N, 3=L3-N).
+ The fourth argument is the measured voltage in tenths of Volts."
+ --#TYPE "APC XPDU: Bypass input voltage back in range."
+ --#SUMMARY "Bypass input voltage in range."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 317
+
+xPDUBypassVoltageHighAlarm TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsInteger,
+ mtrapargsInteger02, mtrapargsInteger03, mtrapargsString }
+ DESCRIPTION
+ "WARNING: Three-phase bypass input voltage to the device is outside the specified limits.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the phase (1=L1-N, 2=L2-N, 3=L3-N).
+ The fourth argument is the measured voltage in tenths of Volts.
+ The fifth argument is the threshold, in tenths of Volts, above which the alarm was generated."
+ --#TYPE "APC XPDU: Bypass input voltage out-of-range alarm."
+ --#SUMMARY "Bypass input voltage is out-of-range."
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 318
+
+xPDUBypassVoltageHighAlarmCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsInteger,
+ mtrapargsInteger02, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: Three-phase bypass input voltage to the device is back within the specified limits.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the phase (1=L1-N, 2=L2-N, 3=L3-N).
+ The fourth argument is the measured voltage in tenths of Volts."
+ --#TYPE "APC XPDU: Bypass input voltage back in range."
+ --#SUMMARY "Bypass input voltage in range."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 319
+
+xPDUOutputVoltageLowAlarm TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsInteger,
+ mtrapargsInteger02, mtrapargsInteger03, mtrapargsString }
+ DESCRIPTION
+ "WARNING: The device three-phase output voltage of the device is outside the specified limits.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the phase (1=L1-N, 2=L2-N, 3=L3-N).
+ The fourth argument is the measured voltage in tenths of Volts.
+ The fifth argument is the threshold, in tenths of Volts, from which the alarm was generated."
+ --#TYPE "APC XPDU: Output voltage out-of-range alarm."
+ --#SUMMARY "Output voltage is out-of-range."
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 320
+
+xPDUOutputVoltageLowAlarmCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsInteger,
+ mtrapargsInteger02, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: The devices three-phase output voltage is back within the specified limits.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the phase (1=L1-N, 2=L2-N, 3=L3-N).
+ The fourth argument is the measured voltage in tenths of Volts."
+ --#TYPE "APC XPDU: Output voltage back in range."
+ --#SUMMARY "Output voltage in range."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 321
+
+xPDUOutputVoltageHighAlarm TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsInteger,
+ mtrapargsInteger02, mtrapargsInteger03, mtrapargsString }
+ DESCRIPTION
+ "WARNING: The device three-phase output voltage of the device is outside the specified limits.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the phase (1=L1-N, 2=L2-N, 3=L3-N).
+ The fourth argument is the measured voltage in tenths of Volts.
+ The fifth argument is the threshold, in tenths of Volts, above which the alarm was generated."
+ --#TYPE "APC XPDU: Output voltage out-of-range alarm."
+ --#SUMMARY "Output voltage is out-of-range."
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 322
+
+xPDUOutputVoltageHighAlarmCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsInteger,
+ mtrapargsInteger02, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: The devices three-phase output voltage is back within the specified limits.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the phase (1=L1-N, 2=L2-N, 3=L3-N).
+ The fourth argument is the measured voltage in tenths of Volts."
+ --#TYPE "APC XPDU: Output voltage back in range."
+ --#SUMMARY "Output voltage in range."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 323
+
+xPDUOutputCurrentLowAlarm TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsInteger,
+ mtrapargsInteger02, mtrapargsInteger03, mtrapargsString }
+ DESCRIPTION
+ "SEVERE: The devices three-phase load current is outside the specified limits.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the phase (1=L1, 2=L2, 3=L3).
+ The fourth argument is the measured current in tenths of Amps.
+ The fifth argument is the threshold, in Amps, from which the alarm was generated."
+ --#TYPE "APC XPDU: Output (load) current out-of-range alarm."
+ --#SUMMARY "Output current is out-of-range."
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 324
+
+xPDUOutputCurrentLowAlarmCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsInteger,
+ mtrapargsInteger02, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: The devices three-phase output current is back within the specified limits.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the phase (1=L1, 2=L2, 3=L3).
+ The fourth argument is the measured current in tenths of Amps."
+ --#TYPE "APC XPDU: Output (load) current back in range."
+ --#SUMMARY "Output current in range."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 325
+
+xPDUOutputCurrentHighAlarm TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsInteger,
+ mtrapargsInteger02, mtrapargsInteger03, mtrapargsString }
+ DESCRIPTION
+ "SEVERE: The devices three-phase load current is outside the specified limits.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the phase (1=L1, 2=L2, 3=L3).
+ The fourth argument is the measured current in tenths of Amps.
+ The fifth argument is the threshold, in Amps, above which the alarm was generated."
+ --#TYPE "APC XPDU: Output (load) current out-of-range alarm."
+ --#SUMMARY "Output current is out-of-range."
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 326
+
+xPDUOutputCurrentHighAlarmCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsInteger,
+ mtrapargsInteger02, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: The devices three-phase output current is back within the specified limits.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the phase (1=L1, 2=L2, 3=L3).
+ The fourth argument is the measured current in tenths of Amps."
+ --#TYPE "APC XPDU: Output (load) current back in range."
+ --#SUMMARY "Output current in range."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 327
+
+xPDUOutputFrequencyAlarm TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsInteger, mtrapargsString }
+ DESCRIPTION
+ "SEVERE: The devices output frequency is outside the specified limits.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the frequency deviation from the nominal in tenths of Hertz."
+ --#TYPE "APC XPDU: Output frequency out-of-range alarm."
+ --#SUMMARY "Output frequency is out-of-range."
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 328
+
+xPDUOutputFrequencyAlarmCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: The devices output frequency is back within the specified limits.
+ The first argument is the host device serial number.
+ The second argument is the host device name."
+ --#TYPE "APC XPDU: Output frequency back in range."
+ --#SUMMARY "Output frequency in range."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 329
+
+xPDUSystemGroundCurrentAlarm TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsInteger, mtrapargsString }
+ DESCRIPTION
+ "SEVERE: The devices earth ground current is over the specified limits.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the measured current in tenths of Amps."
+ --#TYPE "APC XPDU: Earth ground current over range alarm."
+ --#SUMMARY "Earth ground current is over limit."
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 330
+
+xPDUSystemGroundCurrentAlarmCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsInteger, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: The devices earth ground current is back within the specified limits.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the measured current in tenths of Amps."
+ --#TYPE "APC XPDU: Earth ground current back in range."
+ --#SUMMARY "Earth ground current in range."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 331
+
+xPDUInputContactStateAbnormal TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsInteger,
+ mtrapargsString02, mtrapargsInteger02, mtrapargsInteger03, mtrapargsString }
+ DESCRIPTION
+ "WARNING: A user input contact on the device has changed to its abnormal state.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the input contact number.
+ The fourth argument is the input contact name.
+ The fifth argument is the input contact state (1=OPEN, 2=CLOSED).
+ The sixth argument is the configured normal input contact state (1=OPEN, 2=CLOSED)."
+ --#TYPE "APC XPDU: Input contact has changed to its abnormal state."
+ --#SUMMARY "Input contact has changed to its abnormal state."
+ --#ARGUMENTS { }
+ --#SEVERITY WARNING
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 332
+
+xPDUInputContactStateNormal TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsInteger,
+ mtrapargsString02, mtrapargsInteger02, mtrapargsInteger03, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: A user input contact on the device has changed to its normal state.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the input contact number.
+ The fourth argument is the input contact name.
+ The fifth argument is the input contact state (1=CLOSED, 2=OPEN).
+ The sixth argument is the configured normal input contact state (1=OPEN, 2=CLOSED)."
+ --#TYPE "APC XPDU: Input contact has changed to its normal state."
+ --#SUMMARY "Input contact has changed to its normal state."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 333
+
+xPDUOutputRelayStateAbnormal TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsInteger,
+ mtrapargsString02, mtrapargsInteger02, mtrapargsInteger03, mtrapargsString }
+ DESCRIPTION
+ "WARNING: An Output Relay on the device has changed to its abnormal state.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the Output Relay number.
+ The fourth argument is the Output Relay name.
+ The fifth argument is the current Output Relay state (1=OPEN, 2=CLOSED).
+ The sixth argument is the configured normal Output Relay state (1=OPEN, 2=CLOSED)."
+ --#TYPE "APC XPDU: Output Relay has changed to its abnormal state."
+ --#SUMMARY "Output Relay has changed to its abnormal state."
+ --#ARGUMENTS { }
+ --#SEVERITY WARNING
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 334
+
+xPDUOutputRelayStateNormal TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsInteger,
+ mtrapargsString02, mtrapargsInteger02, mtrapargsInteger03, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: An Output Relay on the device has changed to its normal state.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the Output Relay number.
+ The fourth argument is the Output Relay name.
+ The fifth argument is the current Output Relay state (1=OPEN, 2=CLOSED).
+ The sixth argument is the configured normal Output Relay state (1=OPEN, 2=CLOSED)."
+ --#TYPE "APC XPDU: Output Relay has changed to its normal state."
+ --#SUMMARY "Output Relay has changed to its normal state."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 335
+
+xPDUCoolingFanAlarm TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsString }
+ DESCRIPTION
+ "SEVERE: The device's internal cooling fans have failed.
+ The first argument is the host device serial number.
+ The second argument is the host device name."
+ --#TYPE "APC XPDU: Cooling fan failure alarm."
+ --#SUMMARY "Cooling fan failure."
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 336
+
+xPDUCoolingFanAlarmCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: The device's cooling fans are now functioning properly.
+ The first argument is the host device serial number.
+ The second argument is the host device name."
+ --#TYPE "APC XPDU: Cooling fan alarm cleared."
+ --#SUMMARY "Cooling fan alarm cleared."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 337
+
+xPDUTransformerTempAlarm TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsString }
+ DESCRIPTION
+ "SEVERE: The device's isolation transformer is over temperature.
+ The first argument is the host device serial number.
+ The second argument is the host device name."
+ --#TYPE "APC XPDU: Isolation transformer over temperature alarm."
+ --#SUMMARY "Transformer temp alarm."
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 338
+
+xPDUTransformerTempAlarmCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: The device's isolation transformer is no longer over temperature.
+ The first argument is the host device serial number.
+ The second argument is the host device name."
+ --#TYPE "APC XPDU: Isolation transformer over temperature alarm cleared."
+ --#SUMMARY "Transformer temp alarm cleared."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 339
+
+xPDUBranchCurrentLowAlarm TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsInteger,
+ mtrapargsInteger02, mtrapargsInteger03, mtrapargsString }
+ DESCRIPTION
+ "SEVERE: The current in a branch circuit is outside the limits specified for that
+ branch circuit.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the panel position of the branch circuit (1-based index).
+ The fourth argument is the measured current in tenths of Amps.
+ The fifth argument is the threshold, in tenth of Amps, from which the alarm was generated."
+ --#TYPE "APC XPDU: Branch circuit current out-of-range alarm."
+ --#SUMMARY "Branch circuit current is out-of-range."
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 340
+
+xPDUBranchCurrentLowAlarmCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsInteger,
+ mtrapargsInteger02, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: The current in a branch circuit is back within the limits
+ specified for that branch circuit.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the panel position of the branch circuit (1-based index).
+ The fourth argument is the measured current in tenths of Amps."
+ --#TYPE "APC XPDU: Branch circuit current back in range."
+ --#SUMMARY "Branch circuit current in range."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 341
+
+xPDUBranchCurrentHighAlarm TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsInteger,
+ mtrapargsInteger02, mtrapargsInteger03, mtrapargsString }
+ DESCRIPTION
+ "SEVERE: The current in a branch circuit is outside the limits specified for that
+ branch circuit.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the panel position of the branch circuit (1-based index).
+ The fourth argument is the measured current in tenths of Amps.
+ The fifth argument is the threshold, in tenth of Amps, above which the alarm was generated."
+ --#TYPE "APC XPDU: Branch circuit current out-of-range alarm."
+ --#SUMMARY "Branch circuit current is out-of-range."
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 342
+
+xPDUBranchCurrentHighAlarmCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsInteger,
+ mtrapargsInteger02, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: The current in a branch circuit is back within the limits
+ specified for that branch circuit.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the panel position of the branch circuit (1-based index).
+ The fourth argument is the measured current in tenths of Amps."
+ --#TYPE "APC XPDU: Branch circuit current back in range."
+ --#SUMMARY "Branch circuit current in range."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 343
+
+
+xPDUInternalCommError TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsString }
+ DESCRIPTION
+ "SEVERE: There is an internal communication error in the device.
+ The first argument is the host device serial number.
+ The second argument is the host device name."
+ --#TYPE "APC XPDU: Internal communication error."
+ --#SUMMARY "Internal communication error."
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 344
+
+emsHardwareStateAbnormal TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { emsIdentSerialNumber, emsIdentEMSName, mtrapargsString }
+ DESCRIPTION
+ "SEVERE: The device's hardware is improperly configured and operating outside
+ normal bounds for the hardware. This can be caused by improper devices being
+ connected to the EMS ports or Alink Current limit detection."
+ --#TYPE "APC EMS: Hardware is in an abnormal state."
+ --#SUMMARY "Hardware is in an abnormal state."
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 345
+
+emsHardwareStateNormal TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { emsIdentSerialNumber, emsIdentEMSName, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: The device's hardware is in its normal operational state.
+ The first argument is the host device serial number."
+ --#TYPE "APC EMS: Hardware is in a normal state."
+ --#SUMMARY "Hardware is in its normal state."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 346
+
+ceSevereCondition TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString02, mtrapargsInteger, mtrapargsString }
+ DESCRIPTION
+ "SEVERE: A Custom Event severe condition was detected.
+ The first variable is the custom event text message.
+ The second variable is the custom event number."
+ --#TYPE "APC CustomEvent: A severe condition was detected. "
+ --#SUMMARY "A severe condition was detected. "
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 347
+
+ceSevereConditionCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString02, mtrapargsInteger, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: A Custom Event severe condition was cleared.
+ The first variable is the custom event text message.
+ The second variable is the custom event number."
+ --#TYPE "APC CustomEvent: A severe condition was cleared. "
+ --#SUMMARY "A severe condition was cleared. "
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 348
+
+ceWarningCondition TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString02, mtrapargsInteger, mtrapargsString }
+ DESCRIPTION
+ "WARNING: A Custom Event warning condition was detected.
+ The first variable is the custom event text message.
+ The second variable is the custom event number."
+ --#TYPE "APC CustomEvent: A warning condition was detected. "
+ --#SUMMARY "A warning condition was detected. "
+ --#SEVERITY WARNING
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 349
+
+ceWarningConditionCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString02, mtrapargsInteger, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: A Custom Event warning condition was cleared.
+ The first variable is the custom event text message.
+ The second variable is the custom event number."
+ --#TYPE "APC CustomEvent: A warning condition was cleared. "
+ --#SUMMARY "A warning condition was cleared. "
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 350
+
+ceInformationalCondition TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString02, mtrapargsInteger, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: A Custom Event informational condition was detected.
+ The first variable is the custom event text message.
+ The second variable is the custom event number."
+ --#TYPE "APC CustomEvent: Informational condition detected. "
+ --#SUMMARY "An informational condition was detected. "
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 351
+
+ceInformationalConditionCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString02, mtrapargsInteger, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: A Custom Event informational condition was cleared.
+ The first variable is the custom event text message.
+ The second variable is the custom event number."
+ --#TYPE "APC CustomEvent: Informational condition was cleared. "
+ --#SUMMARY "An informational condition was cleared. "
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 352
+
+upsInternalOverTemperature TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString }
+ DESCRIPTION
+ "WARNING: The internal over temperature condition exists."
+ --#TYPE "APC UPS: The internal over temperature condition exists."
+ --#SUMMARY "The internal over temperature condition exists."
+ --#SEVERITY WARNING
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 353
+
+upsInternalOverTemperatureCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: The internal over temperature condition cleared."
+ --#TYPE "APC UPS: The internal over temperature condition cleared."
+ --#SUMMARY "The internal over temperature condition cleared."
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 354
+
+upsMpuReset TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: The MPU has been reset."
+ --#TYPE "APC UPS: The MPU has been reset."
+ --#SUMMARY "The MPU has been reset."
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 355
+
+upsOutputSwitchClosed TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: The Output Switch is closed."
+ --#TYPE "APC UPS: The Output Switch is closed."
+ --#SUMMARY "The Output Switch is closed."
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 356
+
+upsOutputSwitchOpened TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: The Output Switch is open."
+ --#TYPE "APC UPS: The Output Switch is open."
+ --#SUMMARY "The Output Switch is open."
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 357
+
+upsCalibrationStackChanged TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: A calibration value in the stack was changed."
+ --#TYPE "APC UPS: A calibration value in the stack was changed."
+ --#SUMMARY "A calibration value in the stack was changed."
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 358
+
+
+-- Upgraded EMS now has more env traps
+
+envMaxTempThresholdViolation TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { emsIdentSerialNumber, emsIdentEMSName, emsProbeStatusProbeTemperature, emsStatusSysTempUnits,
+ emsProbeStatusProbeIndex, emsProbeStatusProbeName, mtrapargsString }
+ DESCRIPTION
+ "SEVERE: Max temperature threshold violated on the probe.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the current temperature.
+ The fourth argument is the temperature scale.
+ The fifth argument is the probe number.
+ The sixth argument is the probe name."
+ --#TYPE "APC ENV: Max temperature threshold violation."
+ --#SUMMARY "Max temperature threshold violation."
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 359
+
+envMaxTempThresholdViolationCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { emsIdentSerialNumber, emsIdentEMSName, emsProbeStatusProbeTemperature, emsStatusSysTempUnits,
+ emsProbeStatusProbeIndex, emsProbeStatusProbeName, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: Max temperature threshold violation cleared on the probe.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the current temperature.
+ The fourth argument is the temperature scale.
+ The fifth argument is the probe number.
+ The sixth argument is the probe name."
+ --#TYPE "APC ENV: Max temperature threshold violation cleared."
+ --#SUMMARY "Max temperature threshold violation cleared."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 360
+
+envMinTempThresholdViolation TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { emsIdentSerialNumber, emsIdentEMSName, emsProbeStatusProbeTemperature, emsStatusSysTempUnits,
+ emsProbeStatusProbeIndex, emsProbeStatusProbeName, mtrapargsString }
+ DESCRIPTION
+ "SEVERE: Min temperature threshold violated on the probe.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the current temperature.
+ The fourth argument is the temperature scale.
+ The fifth argument is the probe number.
+ The sixth argument is the probe name."
+ --#TYPE "APC ENV: Min temperature threshold violation."
+ --#SUMMARY "Min temperature threshold violation."
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 361
+
+envMinTempThresholdViolationCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { emsIdentSerialNumber, emsIdentEMSName, emsProbeStatusProbeTemperature, emsStatusSysTempUnits,
+ emsProbeStatusProbeIndex, emsProbeStatusProbeName, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: Min temperature threshold violation cleared on the probe.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the current temperature.
+ The fourth argument is the temperature scale.
+ The fifth argument is the probe number.
+ The sixth argument is the probe name."
+ --#TYPE "APC ENV: Min temperature threshold violation cleared."
+ --#SUMMARY "Min temperature threshold violation cleared."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 362
+
+envMaxHumidityThresholdViolation TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { emsIdentSerialNumber, emsIdentEMSName, emsProbeStatusProbeHumidity,
+ emsProbeStatusProbeIndex, emsProbeStatusProbeName, mtrapargsString }
+ DESCRIPTION
+ "SEVERE: Max humidity threshold violated on the probe.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the current humidity
+ The fourth argument is the probe number.
+ The fifth argument is the probe name."
+ --#TYPE "APC ENV: Max humidity threshold violation."
+ --#SUMMARY "Max humidity threshold violation."
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 363
+
+envMaxHumidityThresholdViolationCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { emsIdentSerialNumber, emsIdentEMSName, emsProbeStatusProbeHumidity,
+ emsProbeStatusProbeIndex, emsProbeStatusProbeName, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: Max humidity threshold violation cleared on the probe.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the current humidity.
+ The fourth argument is the probe number.
+ The fifth argument is the probe name."
+ --#TYPE "APC ENV: Max humidity threshold violation cleared."
+ --#SUMMARY "Max humidity threshold violation cleared."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 364
+
+envMinHumidityThresholdViolation TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { emsIdentSerialNumber, emsIdentEMSName, emsProbeStatusProbeHumidity,
+ emsProbeStatusProbeIndex, emsProbeStatusProbeName, mtrapargsString }
+ DESCRIPTION
+ "SEVERE: Min humidity threshold violated on the probe.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the current humidity
+ The fourth argument is the probe number.
+ The fifth argument is the probe name."
+ --#TYPE "APC ENV: Min humidity threshold violation."
+ --#SUMMARY "Min humidity threshold violation."
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 365
+
+envMinHumidityThresholdViolationCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { emsIdentSerialNumber, emsIdentEMSName, emsProbeStatusProbeHumidity,
+ emsProbeStatusProbeIndex, emsProbeStatusProbeName, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: Min humidity threshold violation cleared on the probe.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the current humidity.
+ The fourth argument is the probe number.
+ The fifth argument is the probe name."
+ --#TYPE "APC ENV: Min humidity threshold violation cleared."
+ --#SUMMARY "Min humidity threshold violation cleared."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 366
+
+envSTIncTempRateViolation TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { emsIdentSerialNumber, emsIdentEMSName, emsProbeStatusProbeTemperature, emsStatusSysTempUnits,
+ emsProbeStatusProbeIndex, emsProbeStatusProbeName, mtrapargsString }
+ DESCRIPTION
+ "SEVERE: Short-term increasing temperature rate violated on the probe.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the current temperature.
+ The fourth argument is the temperature scale.
+ The fifth argument is the probe number.
+ The sixth argument is the probe name."
+ --#TYPE "APC ENV: Short-term inc. temp rate violation."
+ --#SUMMARY "Short-term inc. temp rate violation."
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 367
+
+envSTIncTempRateViolationCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { emsIdentSerialNumber, emsIdentEMSName, emsProbeStatusProbeTemperature, emsStatusSysTempUnits,
+ emsProbeStatusProbeIndex, emsProbeStatusProbeName, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: Short-term increasing temperature rate cleared on the probe.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the current temperature.
+ The fourth argument is the temperature scale.
+ The fifth argument is the probe number.
+ The sixth argument is the probe name."
+ --#TYPE "APC ENV: Short-term inc. temp rate violation cleared."
+ --#SUMMARY "Short-term inc. temp rate violation cleared."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 368
+
+envSTDecTempRateViolation TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { emsIdentSerialNumber, emsIdentEMSName, emsProbeStatusProbeTemperature, emsStatusSysTempUnits,
+ emsProbeStatusProbeIndex, emsProbeStatusProbeName, mtrapargsString }
+ DESCRIPTION
+ "SEVERE: Short-term decreasing temperature rate violated on the probe.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the current temperature.
+ The fourth argument is the temperature scale.
+ The fifth argument is the probe number.
+ The sixth argument is the probe name."
+ --#TYPE "APC ENV: Short-term dec. temp rate violation."
+ --#SUMMARY "Short-term dec. temp rate violation."
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 369
+
+envSTDecTempRateViolationCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { emsIdentSerialNumber, emsIdentEMSName, emsProbeStatusProbeTemperature, emsStatusSysTempUnits,
+ emsProbeStatusProbeIndex, emsProbeStatusProbeName, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: Short-term decreasing temperature rate cleared on the probe.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the current temperature.
+ The fourth argument is the temperature scale.
+ The fifth argument is the probe number.
+ The sixth argument is the probe name."
+ --#TYPE "APC ENV: Short-term dec. temp rate violation cleared."
+ --#SUMMARY "Short-term dec. temp rate violation cleared."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 370
+
+envLTIncTempRateViolation TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { emsIdentSerialNumber, emsIdentEMSName, emsProbeStatusProbeTemperature, emsStatusSysTempUnits,
+ emsProbeStatusProbeIndex, emsProbeStatusProbeName, mtrapargsString }
+ DESCRIPTION
+ "SEVERE: Long-term increasing temperature rate violated on the probe.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the current temperature.
+ The fourth argument is the temperature scale.
+ The fifth argument is the probe number.
+ The sixth argument is the probe name."
+ --#TYPE "APC ENV: Long-term inc. temp rate violation."
+ --#SUMMARY "Long-term inc. temp rate violation."
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 371
+
+envLTIncTempRateViolationCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { emsIdentSerialNumber, emsIdentEMSName, emsProbeStatusProbeTemperature, emsStatusSysTempUnits,
+ emsProbeStatusProbeIndex, emsProbeStatusProbeName, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: Long-term increasing temperature rate cleared on the probe.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the current temperature.
+ The fourth argument is the temperature scale.
+ The fifth argument is the probe number.
+ The sixth argument is the probe name."
+ --#TYPE "APC ENV: Long-term inc. temp rate violation cleared."
+ --#SUMMARY "Long-term inc. temp rate violation cleared."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 372
+
+envLTDecTempRateViolation TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { emsIdentSerialNumber, emsIdentEMSName, emsProbeStatusProbeTemperature, emsStatusSysTempUnits,
+ emsProbeStatusProbeIndex, emsProbeStatusProbeName, mtrapargsString }
+ DESCRIPTION
+ "SEVERE: Long-term decreasing temperature rate violated on the probe.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the current temperature.
+ The fourth argument is the temperature scale.
+ The fifth argument is the probe number.
+ The sixth argument is the probe name."
+ --#TYPE "APC ENV: Long-term dec. temp rate violation."
+ --#SUMMARY "Long-term dec. temp rate violation."
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 373
+
+envLTDecTempRateViolationCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { emsIdentSerialNumber, emsIdentEMSName, emsProbeStatusProbeTemperature, emsStatusSysTempUnits,
+ emsProbeStatusProbeIndex, emsProbeStatusProbeName, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: Long-term decreasing temperature rate cleared on the probe.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the current temperature.
+ The fourth argument is the temperature scale.
+ The fifth argument is the probe number.
+ The sixth argument is the probe name."
+ --#TYPE "APC ENV: Long-term dec. temp rate violation cleared."
+ --#SUMMARY "Long-term dec. temp rate violation cleared."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 374
+
+-- Battery Management System Traps
+
+bmsCriticalCondition TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString02, mtrapargsInteger, mtrapargsString }
+ DESCRIPTION
+ "SEVERE: A Battery Management System critical condition was detected.
+ The first variable is the error condition text message.
+ The second variable is the error number."
+ --#TYPE "APC BMS: A critical condition was detected. "
+ --#SUMMARY "A critical condition was detected. "
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 375
+
+bmsCriticalConditionCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString02, mtrapargsInteger, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: A Battery Management System critical condition was cleared.
+ The first variable is the error condition text message.
+ The second variable is the error number."
+ --#TYPE "APC BMS: A critical condition was cleared. "
+ --#SUMMARY "A critical condition was cleared. "
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 376
+
+bmsWarningCondition TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString02, mtrapargsInteger, mtrapargsString }
+ DESCRIPTION
+ "WARNING: A Battery Management System warning condition was detected.
+ The first variable is the error condition text message.
+ The second variable is the error number."
+ --#TYPE "APC BMS: A warning condition was detected. "
+ --#SUMMARY "A warning condition was detected. "
+ --#SEVERITY WARNING
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 377
+
+bmsWarningConditionCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString02, mtrapargsInteger, mtrapargsString }
+ DESCRIPTION
+ "WARNING: A Battery Management System warning condition was cleared.
+ The first variable is the error condition text message.
+ The second variable is the error number."
+ --#TYPE "APC BMS: A warning condition was cleared. "
+ --#SUMMARY "A warning condition was cleared. "
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 378
+
+bmsInformationalCondition TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString02, mtrapargsInteger, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: A Battery Management System informational condition was detected.
+ The first variable is the error condition text message.
+ The second variable is the error number."
+ --#TYPE "APC BMS: Informational condition detected. "
+ --#SUMMARY "An informational condition was detected. "
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 379
+
+bmsInformationalConditionCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsString02, mtrapargsInteger, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: A Battery Management System informational condition was cleared.
+ The first variable is the error condition text message.
+ The second variable is the error number."
+ --#TYPE "APC BMS: Informational condition was cleared. "
+ --#SUMMARY "An informational condition was cleared. "
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 380
+
+-- xATS Traps
+
+xATSOutputVoltageLowAlarm TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger,
+ mtrapargsInteger02, mtrapargsInteger03, mtrapargsString }
+ DESCRIPTION
+ "SEVERE: The device three-phase output voltage of the device is outside the specified limits.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the phase (1=L1-N, 2=L2-N, 3=L3-N, 4=unused, 5=L1-L2, 6=L2-L3, 7=L3-L1).
+ The fourth argument is the measured voltage in tenths of Volts.
+ The fifth argument is the threshold, in tenths of Volts, from which the alarm was generated."
+ --#TYPE "APC XATS: Output voltage out-of-range alarm."
+ --#SUMMARY "Output voltage is out-of-range."
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 381
+
+xATSOutputVoltageLowAlarmCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger,
+ mtrapargsInteger02, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: The devices three-phase output voltage is back within the specified limits.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the phase (1=L1-N, 2=L2-N, 3=L3-N, 4=unused, 5=L1-L2, 6=L2-L3, 7=L3-L1).
+ The fourth argument is the measured voltage in tenths of Volts."
+ --#TYPE "APC XATS: Output voltage back in range."
+ --#SUMMARY "Output voltage in range."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 382
+
+xATSOutputVoltageHighAlarm TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger,
+ mtrapargsInteger02, mtrapargsInteger03, mtrapargsString }
+ DESCRIPTION
+ "SEVERE: The device three-phase output voltage of the device is outside the specified limits.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the phase (1=L1-N, 2=L2-N, 3=L3-N, 4=unused, 5=L1-L2, 6=L2-L3, 7=L3-L1).
+ The fourth argument is the measured voltage in tenths of Volts.
+ The fifth argument is the threshold, in tenths of Volts, above which the alarm is generated."
+ --#TYPE "APC XATS: Output voltage out-of-range alarm."
+ --#SUMMARY "Output voltage is out-of-range."
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 383
+
+xATSOutputVoltageHighAlarmCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger,
+ mtrapargsInteger02, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: The devices three-phase output voltage is back within the specified limits.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the phase (1=L1-N, 2=L2-N, 3=L3-N, 4=unused, 5=L1-L2, 6=L2-L3, 7=L3-L1).
+ The fourth argument is the measured voltage in tenths of Volts."
+ --#TYPE "APC XATS: Output voltage back in range."
+ --#SUMMARY "Output voltage in range."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 384
+
+xATSOutputCurrentLowAlarm TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger,
+ mtrapargsInteger02, mtrapargsInteger03, mtrapargsString }
+ DESCRIPTION
+ "SEVERE: The devices three-phase load current is outside the specified limits.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the phase (1=L1, 2=L2, 3=L3, 4=Neutral, 5=L1-2, 6=L2-3, 7=L3-1).
+ The fourth argument is the measured current in Amps.
+ The fifth argument is the threshold, in Amps, from which the alarm was generated."
+ --#TYPE "APC XATS: Output (load) current out-of-range alarm."
+ --#SUMMARY "Output current is out-of-range."
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 385
+
+xATSOutputCurrentLowAlarmCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger,
+ mtrapargsInteger02, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: The devices three-phase output current is back within the specified limits.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the phase (1=L1, 2=L2, 3=L3, 4=Neutral).
+ The fourth argument is the measured current in Amps."
+ --#TYPE "APC XATS: Output (load) current back in range."
+ --#SUMMARY "Output current in range."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 386
+
+xATSOutputCurrentHighAlarm TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger,
+ mtrapargsInteger02, mtrapargsInteger03, mtrapargsString }
+ DESCRIPTION
+ "SEVERE: The devices three-phase load current is outside the specified limits.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the phase (1=L1, 2=L2, 3=L3, 4=Neutral).
+ The fourth argument is the measured current in Amps.
+ The fifth argument is the threshold, in Amps, from which the alarm was generated."
+ --#TYPE "APC XATS: Output (load) current out-of-range alarm."
+ --#SUMMARY "Output current is out-of-range."
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 387
+
+xATSOutputCurrentHighAlarmCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger,
+ mtrapargsInteger02, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: The devices three-phase output current is back within the specified limits.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the phase (1=L1, 2=L2, 3=L3, 4=Neutral).
+ The fourth argument is the measured current in Amps."
+ --#TYPE "APC XATS: Output (load) current back in range."
+ --#SUMMARY "Output current in range."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 388
+
+
+xATSOutputFrequencyAlarm TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger,
+ mtrapargsInteger02, mtrapargsString }
+ DESCRIPTION
+ "SEVERE: The devices output frequency is outside the specified limits.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the frequency deviation from the nominal in tenths of Hertz.
+ The fourth argument is the frequency deviation threshold in tenths of Hertz,
+ from which the alarm was generated."
+ --#TYPE "APC XATS: Output frequency out-of-range alarm."
+ --#SUMMARY "Output frequency is out-of-range."
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 389
+
+xATSOutputFrequencyAlarmCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: The devices output frequency is back within the specified limits.
+ The first argument is the host device serial number.
+ The second argument is the host device name."
+ --#TYPE "APC XATS: Output frequency back in range."
+ --#SUMMARY "Output frequency in range."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 390
+
+xATSInternalCommError TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsString }
+ DESCRIPTION
+ "SEVERE: There is an internal communication error in the device.
+ The first argument is the host device serial number.
+ The second argument is the host device name."
+ --#TYPE "APC XATS: Internal communication error."
+ --#SUMMARY "Internal communication error."
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 391
+
+xATSInternalCommErrorCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: Internal communication has been restored.
+ The first argument is the host device serial number.
+ The second argument is the host device name."
+ --#TYPE "APC XATS: Internal Communication error cleared."
+ --#SUMMARY "ATS Communication error cleared."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 392
+
+xATSDataCommMismatchError TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsString }
+ DESCRIPTION
+ "SEVERE: A data incompatibility exists within the device. This
+ is typically the result of mismatches between firmware revisions
+ of the transfer switch controller and the Network Management interface.
+ The first argument is the host device serial number.
+ The second argument is the host device name."
+ --#TYPE "APC XATS: Data mismatch error."
+ --#SUMMARY "ATS data mismatch error."
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 393
+
+xATSDataCommMismatchErrorCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: The internal data incompatibility has been resolved.
+ The first argument is the host device serial number.
+ The second argument is the host device name."
+ --#TYPE "APC XATS: data mismatch error cleared."
+ --#SUMMARY "ATS data mismatch error cleared."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 394
+
+xATSGenCommLost TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsString }
+ DESCRIPTION
+ "WARNING: The XATS cannot communicate with the generator.
+ This will make unavailable all the xATSGenerator OIDs.
+ The first argument is the host device serial number.
+ The second argument is the host device name."
+ --#TYPE "APC XATS: No communication with generator."
+ --#SUMMARY "ATS/Generator communication lost."
+ --#ARGUMENTS { }
+ --#SEVERITY WARNING
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 395
+
+xATSGenCommEstablished TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: The XATS has established communication with the generator.
+ The first argument is the host device serial number.
+ The second argument is the host device name."
+ --#TYPE "APC XATS: Communication with generator established."
+ --#SUMMARY "ATS/generator communication established."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 396
+
+xATSNeutralPosition TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger,
+ mtrapargsString }
+ DESCRIPTION
+ "WARNING: XATS has transferred to neutral position.
+ In this position neither Source 1 nor Source 2 is selected,
+ and the XATS will have no output voltage.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the mode in which the switch is operating
+ (1=Auto, 2=Not-in-Auto, Abnormal Condition 3=Not-in-Auto, manual)."
+ --#TYPE "APC XATS: Transferred to the neutral (no output power) position."
+ --#SUMMARY "Transferred to neutral."
+ --#ARGUMENTS { }
+ --#SEVERITY WARNING
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 397
+
+xATSSwitchTransferEvent TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger,
+ mtrapargsInteger02, mtrapargsInteger03, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: XATS has transferred from one source to the other.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the mode in which the switch is operating.
+ (1=Auto, 2=Not-in-Auto, Abnormal Condition 3=Not-in-Auto, manual).
+ The fourth argument is the input source selected (1=Source 1, 2=Source 2).
+ The fifth argument is type of transfer that took place. (1=Closed, 2=Open, 3=Unknown)"
+ --#TYPE "APC XATS: Transferred from Source-X to Source-Y."
+ --#SUMMARY "Source-to-Source transfer."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 398
+
+xATSInternalATSFault TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString }
+ DESCRIPTION
+ "SEVERE: An internal XATS fault has been detected.
+ The XATS may have forced itself to not-in-auto mode (abnormal condition),
+ as indicated by the xATSSwitchStatusAutoSwitchOperationalMode OID.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument indicates the detected fault.
+
+ 1=Cannot Close S1
+ 2=Cannot Close S2
+ 3=Cannot Open S1
+ 4=Cannot Open S2
+ 5=Cannot Trip Open S1
+ 6=Cannot Trip Open S2
+ 7=Start Contact Failure
+ 8=Voltage Sensing Failure"
+
+ --#TYPE "APC XATS: Internal fault detected."
+ --#SUMMARY "ATS internal fault detected."
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 399
+
+xATSInternalATSFaultCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: The detected internal XATS fault has been cleared.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument indicates the detected fault.
+
+ 1=Cannot Close S1
+ 2=Cannot Close S2
+ 3=Cannot Open S1
+ 4=Cannot Open S2
+ 5=Cannot Trip Open S1
+ 6=Cannot Trip Open S2
+ 7=Start Contact Failure
+ 8=Voltage Sensing Failure"
+
+ --#TYPE "APC XATS: Internal fault cleared."
+ --#SUMMARY "ATS internal fault cleared."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 400
+
+xATSEngineStartAsserted TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: The XATS has asserted the Engine Start contact.
+ This should result in the generator producing output voltage.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument indicates the reason that the start signal was asserted
+ 1=Unknown, 2=S1 Low Voltage, 3=S1 High Voltage, 4=S1 Line Imbalance,
+ 5=S1 Freq Range, 6=S1 Bad Rotation."
+ --#TYPE "APC XATS: Engine Start signal asserted."
+ --#SUMMARY "Engine Start asserted."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 401
+
+xATSEngineStopAsserted TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: The XATS has de-asserted the Engine Start contact.
+ This should result in the generator shutting down, and producing no output voltage.
+ The first argument is the host device serial number.
+ The second argument is the host device name."
+ --#TYPE "APC XATS: Engine Stop signal asserted."
+ --#SUMMARY "Engine Stop asserted."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 402
+
+xATSStartFailure TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsString }
+ DESCRIPTION
+ "SEVERE: The generator failed to start. After assertion of the
+ Engine Start signal, the quality of Source 2 was not seen as good.
+ This alarm can be cleared using the xATSSwitchStatusClearLatchedAlarms OID.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument indicates the line quality at S2
+ 1=Unknown, 2=S2 Low Voltage, 3=S2 High Voltage, 4=S2 Line Imbalance,
+ 4=S2 Freq Range, 5=S2 Bad Rotation."
+ --#TYPE "APC XATS: Generator failed to start alarm."
+ --#SUMMARY "Generator failed to start."
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 403
+
+xATSStopFailure TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsString }
+ DESCRIPTION
+ "WARNING: The generator failed to stop. After de-assertion of the
+ Engine Start signal, the quality of Source 2 continued to be seen as good.
+ This alarm can be cleared using the xATSSwitchStatusClearLatchedAlarms OID.
+ The first argument is the host device serial number.
+ The second argument is the host device name."
+ --#TYPE "APC XATS: Generator failed to stop alarm."
+ --#SUMMARY "Generator failed to stop."
+ --#ARGUMENTS { }
+ --#SEVERITY WARNING
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 404
+
+xATSNotInAutomaticMode TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsString }
+ DESCRIPTION
+ "SEVERE: Automatic Transfer Switch is not in automatic mode.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The xATSSwitchStatusAutoSwitchStatus OID and the
+ xATSSwitchStatusAutoSwitchOperationalMode OID
+ can provide more information about the state of the XATS."
+ --#TYPE "APC XATS: XATS is not-in-automatic mode."
+ --#SUMMARY "ATS not in auto."
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 405
+
+xATSNotInAutomaticModeCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: Automatic Transfer Switch is in automatic mode.
+ The first argument is the host device serial number.
+ The second argument is the host device name."
+ --#TYPE "APC XATS: XATS in auto mode."
+ --#SUMMARY "ATS in auto mode."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 406
+
+xATSEpoTripped TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsString }
+ DESCRIPTION
+ "SEVERE: The device's Emergency Power Off (EPO) circuit is tripped.
+ The first argument is the host device serial number.
+ The second argument is the host device name."
+ --#TYPE "APC XATS: Emergency Power Off (EPO) tripped."
+ --#SUMMARY "EPO tripped."
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 407
+
+xATSEpoReset TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: The device's Emergency Power Off (EPO) circuit has been
+ reset to the armed position.
+ The first argument is the host device serial number.
+ The second argument is the host device name."
+ --#TYPE "APC XATS: Emergency Power Off (EPO) reset."
+ --#SUMMARY "EPO armed."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 408
+
+xATSEpoTestMode TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsString }
+ DESCRIPTION
+ "WARNING: The device's Emergency Power Off (EPO) circuit has been
+ switched back to the test position.
+ The first argument is the host device serial number.
+ The second argument is the host device name."
+ --#TYPE "APC XATS: Emergency Power Off (EPO) in test mode."
+ --#SUMMARY "EPO disabled."
+ --#ARGUMENTS { }
+ --#SEVERITY WARNING
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 409
+
+xATSEpoArmed TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: The device's Emergency Power Off (EPO) circuit has been
+ switched back to the armed position.
+ The first argument is the host device serial number.
+ The second argument is the host device name."
+ --#TYPE "APC XATS: Emergency Power Off (EPO) enabled."
+ --#SUMMARY "EPO armed."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 410
+
+xATSTestInitiated TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: A scheduled test has been initiated.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the type of test initiated (1=scheduled, 2=manual)."
+ --#TYPE "APC XATS: Test initiated."
+ --#SUMMARY "Test initiated."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 411
+
+xATSTestCancelled TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: The scheduled test has been canceled
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the type of test initiated (1=scheduled, 2=manual)."
+ --#TYPE "APC XATS: Test cancelled."
+ --#SUMMARY "Test cancelled."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 412
+
+xATSTestFailed TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsString }
+ DESCRIPTION
+ "SEVERE: The initiated test has failed.
+ This alarm can be cleared using the xATSSwitchStatusClearLatchedAlarms OID.
+ The first argument is the host device serial number.
+ The second argument is the host device name."
+ --#TYPE "APC XATS: Initiated test failed."
+ --#SUMMARY "Initiated test failed."
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 413
+
+xATSTestPassed TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: The initiated test has passed
+ switched back to the armed position.
+ The first argument is the host device serial number.
+ The second argument is the host device name."
+ --#TYPE "APC XATS: Initiated test passed."
+ --#SUMMARY "Initiated test passed."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 414
+
+xATSInputContactStateAbnormal TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger,
+ mtrapargsString02, mtrapargsInteger02, mtrapargsInteger03, mtrapargsString }
+ DESCRIPTION
+ "SEVERE: A user input contact on the device has changed to its abnormal state.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the input contact number.
+ The fourth argument is the input contact name.
+ The fifth argument is the input contact state (1=OPEN, 2=CLOSED).
+ The sixth argument is the configured normal input contact state (1=OPEN, 2=CLOSED)."
+ --#TYPE "APC XATS: Input contact has changed to its abnormal state."
+ --#SUMMARY "Input contact has changed to its abnormal state."
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 415
+
+xATSInputContactStateNormal TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger,
+ mtrapargsString02, mtrapargsInteger02, mtrapargsInteger03, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: A user input contact on the device has changed to its normal state.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the input contact number.
+ The fourth argument is the input contact name.
+ The fifth argument is the input contact state (1=OPEN, 2=CLOSED).
+ The sixth argument is the configured normal input contact state (1=OPEN, 2=CLOSED)."
+ --#TYPE "APC XATS: Input contact has changed to its normal state."
+ --#SUMMARY "Input contact has changed to its normal state."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 416
+
+xATSRemoteStartContactMismatch TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsString }
+ DESCRIPTION
+ "SEVERE: The state of the generator's Remote Start input
+ and the ATS's Engine Start output do not match.
+ This indicates something wrong in the Engine Start wiring,
+ which must be corrected. This condition will prevent the
+ generator from being started when needed.
+
+ (See also: xATSGeneratorStatusRemoteStart
+ and xATSSwitchStatusEngineStartSignal OIDs)
+
+ The first argument is the host device serial number.
+ The second argument is the host device name."
+ --#TYPE "APC XATS: Generator/ATS start contact mismatch."
+ --#SUMMARY "Generator/ATS start contact mismatch."
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 417
+
+xATSRemoteStartContactMismatchCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: Mismatch in the state of the generator's
+ Remote Start input and the ATS's Engine Start output as been resolved.
+ This indicates something wrong in the Engine Start wiring,
+ which must be corrected. This condition will prevent the
+ generator from being started when needed.
+
+ (See also: xATSGeneratorStatusRemoteStart
+ and xATSSwitchStatusEngineStartSignal OIDs)
+
+ The first argument is the host device serial number.
+ The second argument is the host device name."
+ --#TYPE "APC XATS: Generator/ATS start contact mismatch cleared."
+ --#SUMMARY "Generator/ATS start contact mismatch cleared."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 418
+
+xATSDoorOpenAlarm TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsString }
+ DESCRIPTION
+ "WARNING: The XATS exterior panel door is open.
+ The first argument is the host device serial number.
+ The second argument is the host device name."
+ --#TYPE "APC XATS: Panel door is open alarm."
+ --#SUMMARY "Panel door open alarm."
+ --#ARGUMENTS { }
+ --#SEVERITY WARNING
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 419
+
+xATSDoorOpenAlarmCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: The external door to the device is closed.
+ The first argument is the host device serial number.
+ The second argument is the host device name."
+ --#TYPE "APC XATS: Panel door open alarm cleared."
+ --#SUMMARY "Panel door open alarm cleared."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 420
+
+xATSDCBackupAlarm TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsString }
+ DESCRIPTION
+ "WARNING: The XATS's DC backup has been lost. The XATS will lose power
+ on Source 1 failure, causing the Engine Start signal to be asserted.
+ The XATS will then restart from Source 2.
+ The first argument is the host device serial number.
+ The second argument is the host device name."
+ --#TYPE "APC XATS: DC backup failure."
+ --#SUMMARY "ATS DC backup failure."
+ --#ARGUMENTS { }
+ --#SEVERITY WARNING
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 421
+
+xATSDCBackupAlarmCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: DC backup alarm has been cleared in the device.
+ The first argument is the host device serial number.
+ The second argument is the host device name."
+ --#TYPE "APC XATS: DC backup alarm cleared."
+ --#SUMMARY "DC backup alarm cleared."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 422
+
+-- xATS Generator Traps
+
+xATSGeneratorLowCoolantLevelAlarm TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString }
+ DESCRIPTION
+ "SEVERE: Low coolant level has been detected in the generator.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the OEM's fault/event code."
+ --#TYPE "APC XGEN: Generator low coolant level alarm."
+ --#SUMMARY "Generator low coolant level alarm."
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 423
+
+xATSGeneratorLowCoolantLevelAlarmCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: The detected low coolant level has been cleared in the generator.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the OEM's fault/event code."
+ --#TYPE "APC XGEN: Generator low coolant level alarm cleared."
+ --#SUMMARY "Generator low coolant level alarm cleared."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 424
+
+xATSGeneratorVeryLowCoolantLevelAlarm TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString }
+ DESCRIPTION
+ "SEVERE: Very low coolant level has been detected in the generator.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the OEM's fault/event code."
+ --#TYPE "APC XGEN: Generator very low coolant level alarm."
+ --#SUMMARY "Generator very low coolant level alarm."
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 425
+
+xATSGeneratorVeryLowCoolantLevelAlarmCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: The detected Very low coolant level has been cleared in the generator.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the OEM's fault/event code."
+ --#TYPE "APC XGEN: Generator very low coolant level alarm cleared."
+ --#SUMMARY "Generator very low coolant level alarm cleared."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 426
+
+xATSGeneratorHighCoolantTempAlarm TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString }
+ DESCRIPTION
+ "SEVERE: High coolant temperature has been detected in the generator.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the OEM's fault/event code."
+ --#TYPE "APC XGEN: Generator high coolant temperature alarm."
+ --#SUMMARY "Generator high coolant temperature alarm."
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 427
+
+xATSGeneratorHighCoolantTempAlarmCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: The detected high coolant temperature has been cleared in the generator.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the OEM's fault/event code."
+ --#TYPE "APC XGEN: Generator high coolant temperature alarm cleared."
+ --#SUMMARY "Generator high coolant temperature alarm cleared."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 428
+
+xATSGeneratorVeryHighCoolantTempAlarm TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString }
+ DESCRIPTION
+ "SEVERE: Very high coolant temperature has been detected in the generator.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the OEM's fault/event code."
+ --#TYPE "APC XGEN: Generator very high coolant temperature alarm."
+ --#SUMMARY "Generator very high coolant temperature alarm."
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 429
+
+xATSGeneratorVeryHighCoolantTempAlarmCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: The Very high coolant temperature condition has been cleared in the generator.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the OEM's fault/event code."
+ --#TYPE "APC XGEN: Generator very high coolant temperature alarm cleared."
+ --#SUMMARY "Generator very high coolant temperature alarm cleared."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 430
+
+xATSGeneratorLowCoolantTempAlarm TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString }
+ DESCRIPTION
+ "WARNING: Low coolant temperature has been detected in the generator.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the OEM's fault/event code."
+ --#TYPE "APC XGEN: Generator low coolant temperature alarm."
+ --#SUMMARY "Generator low coolant temperature alarm."
+ --#ARGUMENTS { }
+ --#SEVERITY WARNING
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 431
+
+xATSGeneratorLowCoolantTempAlarmCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: The low coolant temperature condition has been cleared in the generator.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the OEM's fault/event code."
+ --#TYPE "APC XGEN: Generator low coolant temperature alarm cleared."
+ --#SUMMARY "Generator low coolant temperature alarm cleared."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 432
+
+xATSGeneratorLowOilLevelAlarm TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString }
+ DESCRIPTION
+ "SEVERE: Low oil level has been detected in the generator.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the OEM's fault/event code."
+ --#TYPE "APC XGEN: Generator low oil level alarm."
+ --#SUMMARY "Generator low oil level alarm."
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 433
+
+xATSGeneratorLowOilLevelAlarmCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: Low oil level alarm has been cleared in the generator.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the OEM's fault/event code."
+ --#TYPE "APC XGEN: Generator low oil level alarm cleared."
+ --#SUMMARY "Generator low oil level alarm cleared."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 434
+
+xATSGeneratorLowBatteryVoltDuringCrankAlarm TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString }
+ DESCRIPTION
+ "SEVERE: The generator's battery voltage has been detected
+ as low while cranking the engine.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the OEM's fault/event code."
+ --#TYPE "APC XGEN: Low batt. voltage while cranking alarm."
+ --#SUMMARY "Generator low battery volts while cranking alarm."
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 435
+
+xATSGeneratorLowBatteryVoltDuringCrankAlarmCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: The generator's low battery voltage while
+ cranking condition has been cleared.
+ The second argument is the host device name.
+ The third argument is the OEM's fault/event code."
+ --#TYPE "XGEN: Generator low batt. voltage while cranking alarm cleared."
+ --#SUMMARY "Generator low battery volts while cranking alarm cleared."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 436
+
+xATSGeneratorVeryLowBatteryVoltDuringCrankAlarm TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString }
+ DESCRIPTION
+ "SEVERE: The generator's battery voltage has been detected
+ as very low while cranking the engine.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the OEM's fault/event code."
+ --#TYPE "XGEN: Generator v.low battery voltage while cranking alarm."
+ --#SUMMARY "Generator v.low battery volts while cranking alarm."
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 437
+
+xATSGeneratorVeryLowBatteryVoltDuringCrankAlarmCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: The generator's high battery voltage while
+ cranking condition has been cleared.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the OEM's fault/event code."
+ --#TYPE "XGEN: Generator v.low batt volt, while cranking alarm cleared."
+ --#SUMMARY "Generator v.low battery volts while cranking alarm cleared."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 438
+
+xATSGeneratorEStop TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsInteger02, mtrapargsString }
+ DESCRIPTION
+ "SEVERE: The generator's emergency stop input has been activated.
+ After the emergency stop signal has been removed, the E-Stop condition
+ must be cleared before the generator can be started again.
+ E-Stop conditions can only be cleared via the generator front panel.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the OEM's fault/event code.
+ The fourth argument is the type of E-Stop (1=LOCAL, 2=REMOTE)."
+ --#TYPE "APC XGEN: Generator emergency stop engaged."
+ --#SUMMARY "Generator emergency stop engaged."
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE NONOPERATIONAL
+ ::= 439
+
+xATSGeneratorEStopCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsInteger02, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: The generator's emergency stop condition has been cleared.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the OEM's fault/event code.
+ The fourth argument is the type of E-Stop (1=LOCAL, 2=REMOTE)."
+ --#TYPE "APC XGEN: Generator emergency stop condition cleared."
+ --#SUMMARY "Generator emergency stop condition cleared."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 440
+
+xATSGeneratorHighBatteryVolt TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString }
+ DESCRIPTION
+ "WARNING: The generator's battery voltage has been detected as high.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the OEM's fault/event code."
+ --#TYPE "APC XGEN: Generator high battery voltage."
+ --#SUMMARY "Generator high battery volts."
+ --#ARGUMENTS { }
+ --#SEVERITY WARNING
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 441
+
+xATSGeneratorHighBatteryVoltCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: The detected high battery voltage has been cleared, on the generator.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the OEM's fault/event code."
+ --#TYPE "APC XGEN: Generator high battery voltage condition cleared."
+ --#SUMMARY "Generator high battery volts condition cleared."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 442
+
+xATSGeneratorLowBatteryVolt TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString }
+ DESCRIPTION
+ "SEVERE: The generator's battery voltage has been detected as low.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the OEM's fault/event code."
+ --#TYPE "APC XGEN: Generator low battery voltage."
+ --#SUMMARY "Generator low battery volts."
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 443
+
+xATSGeneratorLowBatteryVoltCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: The detected low battery voltage has been cleared, on the generator.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the OEM's fault/event code."
+ --#TYPE "APC XGEN: Generator low battery voltage condition cleared."
+ --#SUMMARY "Generator low battery volts condition cleared."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 444
+
+xATSGeneratorControlSwitchNotAuto TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString }
+ DESCRIPTION
+ "SEVERE: The control switch on the generator is not in auto position.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the OEM's fault/event code."
+ --#TYPE "APC XGEN: Generator not-in-automatic mode."
+ --#SUMMARY "Generator not-in-auto."
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 445
+
+xATSGeneratorControlSwitchNotAutoCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: The control switch on the generator is in auto position.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the OEM's fault/event code."
+ --#TYPE "APC XGEN: Generator automatic mode restored."
+ --#SUMMARY "Generator not-in-auto cleared."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 446
+
+xATSGeneratorLowOilPressure TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString }
+ DESCRIPTION
+ "SEVERE: The generator's oil pressure has been detected as low.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the OEM's fault/event code."
+ --#TYPE "APC XGEN: Generator low oil pressure."
+ --#SUMMARY "Generator low oil pressure."
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 447
+
+xATSGeneratorLowOilPressureCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: The detected low oil pressure has been cleared, on the generator.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the OEM's fault/event code."
+ --#TYPE "APC XGEN: Generator low oil pressure condition cleared."
+ --#SUMMARY "Generator low oil pressure condition cleared."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 448
+
+xATSGeneratorVeryLowOilPressure TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString }
+ DESCRIPTION
+ "SEVERE: The generator's oil pressure has been detected as very low.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the OEM's fault/event code."
+ --#TYPE "APC XGEN: Generator v.low oil pressure."
+ --#SUMMARY "Generator v.low oil pressure."
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 449
+
+xATSGeneratorVeryLowOilPressureCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: The detected v.low oil pressure has been cleared, on the generator.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the OEM's fault/event code."
+ --#TYPE "APC XGEN: Generator v.low oil pressure condition cleared."
+ --#SUMMARY "Generator v.low oil pressure condition cleared."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 450
+
+xATSGeneratorOverload TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString }
+ DESCRIPTION
+ "SEVERE: The generator is overloaded.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the OEM's fault/event code."
+ --#TYPE "APC XGEN: Generator is in overload event."
+ --#SUMMARY "Generator on overload event."
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 451
+
+xATSGeneratorOverloadCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: The generator is running within loading limits.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the OEM's fault/event code."
+ --#TYPE "APC XGEN: Generator is in overload event cleared."
+ --#SUMMARY "Generator on overload event cleared."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 452
+
+xATSGeneratorLowACVEvent TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString }
+ DESCRIPTION
+ "SEVERE: The generator AC voltage is outside the acceptable bounds.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the OEM's fault/event code."
+ --#TYPE "APC XGEN: State of the Generator ac voltage."
+ --#SUMMARY " State of the Generator ac voltage."
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 453
+
+xATSGeneratorLowACVEventCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: The generator AC voltage is within normal bounds.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the OEM's fault/event code."
+ --#TYPE "APC XGEN: State of the Generator ac voltage cleared."
+ --#SUMMARY "State of the Generator ac voltage cleared."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 454
+
+xATSGeneratorHighACVEvent TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString }
+ DESCRIPTION
+ "SEVERE: The generator AC voltage is outside the acceptable bounds.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the OEM's fault/event code."
+ --#TYPE "APC XGEN: State of the Generator ac voltage."
+ --#SUMMARY " State of the Generator ac voltage."
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 455
+
+xATSGeneratorHighACVEventCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: The generator AC voltage is within normal bounds.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the OEM's fault/event code."
+ --#TYPE "APC XGEN: State of the Generator ac voltage cleared."
+ --#SUMMARY "State of the Generator ac voltage cleared."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 456
+
+xATSGeneratorOverspeed TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString }
+ DESCRIPTION
+ "SEVERE: The generator is running over the acceptable RPM.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the OEM's fault/event code."
+ --#TYPE "APC XGEN: Generator overspeed condition."
+ --#SUMMARY "Generator overspeed condition."
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 457
+
+xATSGeneratorOverspeedCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: The generator overspeed shutdown has been cleared.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the OEM's fault/event code."
+ --#TYPE "APC XGEN: Generator overspeed condition cleared."
+ --#SUMMARY "Generator overspeed condition cleared."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 458
+
+xATSGeneratorEngineCold TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString }
+ DESCRIPTION
+ "SEVERE: The generator engine is cold, may not start.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the OEM's fault/event code."
+ --#TYPE "APC XGEN: Generator engine is cold, may not start."
+ --#SUMMARY "Generator engine is cold."
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 459
+
+xATSGeneratorEngineColdCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: The engine is not cold to start.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the OEM's fault/event code."
+ --#TYPE "APC XGEN: Engine is cold to start condition cleared."
+ --#SUMMARY "Engine is cold to start condition cleared."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 460
+
+xATSGeneratorOutputBreakerOpen TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString }
+ DESCRIPTION
+ "SEVERE: The generators output breaker has been detected as open.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the OEM's fault/event code."
+ --#TYPE "APC XGEN: Generator output breaker open alarm."
+ --#SUMMARY "Generator output breaker open."
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE NONOPERATIONAL
+ ::= 461
+
+xATSGeneratorOutputBreakerOpenCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: The engine is not cold to start.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the OEM's fault/event code."
+ --#TYPE "APC XGEN: Generator output breaker open alarm cleared."
+ --#SUMMARY "Generator output breaker open cleared."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 462
+
+xATSGeneratorLowFuelLevelAlarm TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString }
+ DESCRIPTION
+ "WARNING: The tank fuel level is below the limits specified
+ in the xATSGeneratorFuelSystemLowFuelLevelThreshold OID.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the measured fuel level in percent of full."
+ --#TYPE "APC XGEN: Low fuel level alarm."
+ --#SUMMARY "Generator low fuel level alarm."
+ --#ARGUMENTS { }
+ --#SEVERITY WARNING
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 463
+
+xATSGeneratorLowFuelLevelAlarmCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: The tank fuel level is back above the specified limit.
+ The first argument is the host device serial number.
+ The second argument is the host device name."
+ --#TYPE "APC XGEN: Low fuel level alarm cleared."
+ --#SUMMARY "Generator low fuel level alarm cleared."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 464
+
+xATSGeneratorVeryLowFuelLevelAlarm TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString }
+ DESCRIPTION
+ "SEVERE: The tank fuel level is below the low threshold limits.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the measured tank fuel level in percent of full."
+ --#TYPE "APC XGEN: Very Low fuel level alarm."
+ --#SUMMARY "Generator very low fuel level alarm."
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 465
+
+xATSGeneratorVeryLowFuelLevelAlarmCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: The detected low tank level has been cleared in the device.
+ The first argument is the host device serial number.
+ The second argument is the host device name."
+ --#TYPE "APC XGEN: Very low fuel level alarm cleared."
+ --#SUMMARY "Generator very low fuel level alarm cleared."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 466
+
+xATSGeneratorLowRunTimeAlarm TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString }
+ DESCRIPTION
+ "WARNING: The estimated runtime is below the limits specified.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the estimated runtime in hours."
+ --#TYPE "APC XGEN: Low run time alarm."
+ --#SUMMARY "Generator low run time alarm."
+ --#ARGUMENTS { }
+ --#SEVERITY WARNING
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 467
+
+xATSGeneratorLowRunTimeAlarmCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: The detected low runtime has been cleared in the device.
+ The first argument is the host device serial number.
+ The second argument is the host device name."
+ --#TYPE "APC XGEN: Low run time alarm cleared."
+ --#SUMMARY "Generator low run time alarm."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 468
+
+xATSGeneratorVeryLowRunTimeAlarm TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString }
+ DESCRIPTION
+ "SEVERE: The estimated runtime is below the limits specified
+ in the xATSGeneratorFuelSystemVeryLowRunTimeThreshold OID.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the estimated runtime in hours."
+ --#TYPE "APC XGEN: Very low run time alarm."
+ --#SUMMARY "Generator very low run time alarm."
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 469
+
+xATSGeneratorVeryLowRunTimeAlarmCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: The detected low runtime has been cleared in the device.
+ The first argument is the host device serial number.
+ The second argument is the host device name."
+ --#TYPE "APC XGEN: Very low run time alarm cleared."
+ --#SUMMARY "Generator very low run time alarm."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 470
+
+xATSGeneratorServiceDueAlarm TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsString }
+ DESCRIPTION
+ "WARNING: The generator is due for scheduled service.
+ Generation of this alarm is based on calender days since
+ and/or actual generator run-hours since last service.
+ This alarm is cleared using the xATSGeneratorServiceResetRecord OID.
+
+ (See also: xATSGeneratorServiceCalendarIntervalThreshold
+ and xATSGeneratorServiceRunHoursThreshold OIDs)
+
+ The first argument is the host device serial number.
+ The second argument is the host device name."
+ --#TYPE "APC XATS: Generator scheduled maintenance is due."
+ --#SUMMARY "Generator maintenance due."
+ --#ARGUMENTS { }
+ --#SEVERITY WARNING
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 471
+
+xATSGeneratorServiceDueAlarmCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: The generator's service registers have been reset.
+ The first argument is the host device serial number.
+ The second argument is the host device name."
+ --#TYPE "APC XATS: Generator service due alarm is cleared."
+ --#SUMMARY "Generator service alarm is cleard."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 472
+
+xATSGeneratorShutdown TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString }
+ DESCRIPTION
+ "SEVERE: The generator is shutdown.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the OEM's fault/event code."
+ --#TYPE "APC XGEN: Generator shutdown."
+ --#SUMMARY "Generator shutdown"
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 473
+
+xATSGeneratorShutdownCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: The generator shutdown alarm is cleared.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the OEM's fault/event code."
+ --#TYPE "APC XGEN: Generator shutdown is cleared."
+ --#SUMMARY "Generator shutdown is cleared."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 474
+
+xATSGeneratorBatteryCharger TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString }
+ DESCRIPTION
+ "SEVERE: The generator battery charger is nonfunctional.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the OEM's fault/event code."
+ --#TYPE "APC XGEN: Generator batt. charger is nonfunctional."
+ --#SUMMARY "Generator battery charger is nonfunctional"
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 475
+
+xATSGeneratorBatteryChargerCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: nonfunctionality of the generator battery is cleared.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the OEM's fault/event code."
+ --#TYPE "APC XGEN: " Nonfunctionality of battery charger is cleared."
+ --#SUMMARY "non-functionality of Generator battery charger is cleared."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 476
+
+xATSGeneratorGenericEvent TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString }
+ DESCRIPTION
+ "WARNING: Any generic generator event.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the OEM's fault/event code."
+ --#TYPE "APC XGEN: Generator generic event."
+ --#SUMMARY "Generator generic event."
+ --#ARGUMENTS { }
+ --#SEVERITY WARNING
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 477
+
+xATSGeneratorGenericEventCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xATSIdentSerialNumber, xATSIdentProductName, mtrapargsInteger, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: Generated generic generator event is cleared.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the OEM's fault/event code."
+ --#TYPE "APC XGEN: Generic generator event is cleared."
+ --#SUMMARY "Generic generator event is cleared."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 478
+
+-- xPDU Traps (part 2)
+
+xPDUInternalCommErrorCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: Internal communication has been restored.
+ The first argument is the host device serial number.
+ The second argument is the host device name."
+ --#TYPE "APC XPDU: Internal Communication error cleared."
+ --#SUMMARY "Communication error cleared."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 479
+
+xPDUSystemStateAlarm TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName,
+ mtrapargsInteger, mtrapargsString }
+ DESCRIPTION
+ "WARNING: The PDU's breakers (Q1, Q2 & Q3) are in a configuration that might lead
+ to system unavailability. it may signify a temporary condition, when the breakers
+ are placed in an atypical manner as the user transitions to (UPS OPERATION or MAINTENANCE BYPASS)
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the type of alarm
+ (1=NO UPS INPUT, 2=NO PANEL FEED, 3=ATYPICAL BYPASS MODE)."
+ --#TYPE "APC XPDU: System state alarm ."
+ --#SUMMARY "PDU state alarm."
+ --#ARGUMENTS { }
+ --#SEVERITY WARNING
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 480
+
+xPDUSystemStateNormal TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName,
+ mtrapargsInteger, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: The PDU's breakers (Q1, Q2 & Q3) are set in a configuration
+ that is a non-alarm state.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the type of alarm (1=UPS OPERATION, 2=MAINTENANCE BYPASS)."
+ --#TYPE "APC XPDU: System state returned to normal."
+ --#SUMMARY "PDU state normal."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 481
+
+xPDUEpoTestMode TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsString }
+ DESCRIPTION
+ "WARNING: The device's Emergency Power Off (EPO) circuit has been
+ switched back to the test position.
+ The first argument is the host device serial number.
+ The second argument is the host device name."
+ --#TYPE "APC XPDU: Emergency Power Off (EPO) in test mode."
+ --#SUMMARY "EPO disabled."
+ --#ARGUMENTS { }
+ --#SEVERITY WARNING
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 482
+
+xPDUEpoArmed TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: The device's Emergency Power Off (EPO) circuit has been
+ switched back to the armed position.
+ The first argument is the host device serial number.
+ The second argument is the host device name."
+ --#TYPE "APC XPDU: Emergency Power Off (EPO) enabled."
+ --#SUMMARY "EPO armed."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 483
+
+xPDUFuseBlownAlarm TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName,
+ mtrapargsInteger, mtrapargsString }
+ DESCRIPTION
+ "SEVERE: One or more fuses in this PDU have been detected as open.
+ These fuses are in the feed to the UPS associated with this PDU.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the phase (1=L1, 2=L2, 3=L3)."
+ --#TYPE "APC XPDU: Check fuse alarm."
+ --#SUMMARY "Fuse detected opened."
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 484
+
+xPDUFuseBlownAlarmCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName,
+ mtrapargsInteger, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: A previous check fuse alarm in this PDU has cleared.
+ These fuses are in the feed to the UPS associated with this PDU.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the phase (1=L1, 2=L2, 3=L3)."
+ --#TYPE "APC XPDU: Check fuse alarm cleared."
+ --#SUMMARY "Fuse alarm cleared."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 485
+
+xPDUBreakerPositionAlarm TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName,
+ mtrapargsInteger, mtrapargsInteger02, mtrapargsString }
+ DESCRIPTION
+ "SEVERE: A PDU breaker is in a state that compromises system availability.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the breaker (1=MAIN INPUT, 2=BYPASS INPUT, 3=CROSS TIE).
+ The fourth argument is the breaker position (1=OPEN, 2=CLOSED)."
+ --#TYPE "APC XPDU: Breaker position alarm."
+ --#SUMMARY "Breaker position alarm."
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 486
+
+xPDUBreakerPositionAlarmCleared TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName,
+ mtrapargsInteger, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: A PDU breaker is no longer in a state that compromises system availability.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the breaker (1=MAIN INPUT, 2=BYPASS INPUT, 3=CROSS TIE)."
+ --#TYPE "APC XPDU: Breaker position alarm cleared."
+ --#SUMMARY "Breaker alarm cleared."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 487
+
+xPDUBreakerChangeEvent TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsInteger,
+ mtrapargsInteger02, mtrapargsInteger03, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: A system breaker or switch within the device has changed state.
+ They are generated when any of the Q1, Q2 or Q3 breakers have changed states.
+ The first argument is the host device serial number.
+ The second argument is the host device name.
+ The third argument is the breaker that has changed
+ (1=UPS FEED (Q1), 2=UPS OUTPUT(Q2), 3=MAINTENANCE BYPASS (Q3).
+ The fourth argument is the state of the breaker that has changed (1=OPEN, 2=CLOSED).
+ The fifth argument is a 8-bit field representing the state of all breakers in the system,
+ when any of one of the Q1, Q2 or Q3 breakers have changed state.
+
+ The bit map is represented in the following manner (b7, b6 ... b0)
+ b0 - UPS FEED (Q1)
+ b1 - MAINTENANCE BYPASS (Q3)
+ b2 - UPS OUTPUT (Q2)
+ b3 - MAIN INPUT
+ b4 - BYPASS INPUT
+ b5 - CROSS-TIE OUTPUT
+
+ Example: value of 60 (0x3C) indicates that the CROSS_TIE, BYPASS and MAIN INPUT, and Q2 breakers
+ are CLOSED and Q2, Q1 breakers are OPEN."
+ --#TYPE "APC XPDU: Breaker/switch change event."
+ --#SUMMARY "Breaker/switch change event."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 488
+
+xPDUControllerFirmwareUpdateTransferStart TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: Start Controller firmware transfer in the device.
+ The first argument is the host device serial number.
+ The second argument is the host device name."
+ --#TYPE "APC XPDU: Start controller firmware transfer."
+ --#SUMMARY "Start controller firmware transfer."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 489
+
+xPDUControllerFirmwareUpdateTransferComplete TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: Transfer of Controller firmware was completed in the device.
+ The first argument is the host device serial number.
+ The second argument is the host device name."
+ --#TYPE "APC XPDU: Controller firmware transfer completed."
+ --#SUMMARY "Controller firmware transfer completed."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 490
+
+xPDUControllerFirmwareUpdateTransferFailed TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsString }
+ DESCRIPTION
+ "SEVERE: Transfer of Controller firmware has failed in the PDU.
+ The first argument is the host device serial number.
+ The second argument is the host device name."
+ --#TYPE "APC XPDU: Controller firmware transfer failed."
+ --#SUMMARY "Controller firmware transfer failed."
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 491
+
+xATSControllerFirmwareUpdateTransferStart TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: Start Controller firmware transfer in the device.
+ The first argument is the host device serial number.
+ The second argument is the host device name."
+ --#TYPE "APC XATS: Start controller firmware transfer."
+ --#SUMMARY "Start controller firmware transfer."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 492
+
+xATSControllerFirmwareUpdateTransferComplete TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsString }
+ DESCRIPTION
+ "INFORMATIONAL: Transfer of Controller firmware was completed in the device.
+ The first argument is the host device serial number.
+ The second argument is the host device name."
+ --#TYPE "APC XATS: Controller firmware transfer completed."
+ --#SUMMARY "Controller firmware transfer completed."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 493
+
+xATSControllerFirmwareUpdateTransferFailed TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { xPDUIdentSerialNumber, xPDUIdentProductName, mtrapargsString }
+ DESCRIPTION
+ "SEVERE: Transfer of Controller firmware has failed in the device.
+ The first argument is the host device serial number.
+ The second argument is the host device name."
+ --#TYPE "APC XATS: Controller firmware transfer failed."
+ --#SUMMARY "Controller firmware transfer failed."
+ --#ARGUMENTS { }
+ --#SEVERITY SEVERE
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 494
+
+apcDeviceShutdownHeartbeat TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { mtrapargsInteger, mtrapargsTimeTicks, mtrapargsString}
+ DESCRIPTION
+ "INFORMATIONAL: "
+ --#TYPE "APC X:"
+ --#SUMMARY "."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 999
+
+apcDiscoveryAlarmStateTableUpdate TRAP-TYPE
+ ENTERPRISE apc
+ VARIABLES { apcDiscoveryDeviceAlarmStateChangeCount }
+ DESCRIPTION
+ "INTERNAL: A Discovery Alarm State Table Update trap is sent
+ when any data alarm state is added, removed, or its parameters
+ are changed in the condition table. This trap is
+ only for machine-to-machine communication. "
+ --#TYPE "APC X:"
+ --#SUMMARY "."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 1000
+
+END