diff options
Diffstat (limited to 'doc/man/nbft_ssns.2')
-rw-r--r-- | doc/man/nbft_ssns.2 | 159 |
1 files changed, 159 insertions, 0 deletions
diff --git a/doc/man/nbft_ssns.2 b/doc/man/nbft_ssns.2 new file mode 100644 index 0000000..f2982c7 --- /dev/null +++ b/doc/man/nbft_ssns.2 @@ -0,0 +1,159 @@ +.TH "libnvme" 9 "struct nbft_ssns" "February 2024" "API Manual" LINUX +.SH NAME +struct nbft_ssns \- Subsystem Namespace (SSNS) Descriptor (Figure 15) +.SH SYNOPSIS +struct nbft_ssns { +.br +.BI " __u8 structure_id;" +.br +.BI " __le16 index;" +.br +.BI " __le16 flags;" +.br +.BI " __u8 trtype;" +.br +.BI " __le16 trflags;" +.br +.BI " __u8 primary_discovery_ctrl_index;" +.br +.BI " __u8 reserved1;" +.br +.BI " struct nbft_heap_obj subsys_traddr_obj;" +.br +.BI " struct nbft_heap_obj subsys_trsvcid_obj;" +.br +.BI " __le16 subsys_port_id;" +.br +.BI " __le32 nsid;" +.br +.BI " __u8 nidt;" +.br +.BI " __u8 nid[16];" +.br +.BI " __u8 security_desc_index;" +.br +.BI " __u8 primary_hfi_desc_index;" +.br +.BI " __u8 reserved2;" +.br +.BI " struct nbft_heap_obj secondary_hfi_assoc_obj;" +.br +.BI " struct nbft_heap_obj subsys_ns_nqn_obj;" +.br +.BI " struct nbft_heap_obj ssns_extended_info_desc_obj;" +.br +.BI " __u8 reserved3[62];" +.br +.BI " +}; +.br + +.SH Members +.IP "structure_id" 12 +Structure ID: This field shall be set to 4h +(i.e., SSNS; #NBFT_DESC_SSNS). +.IP "index" 12 +SSNS Descriptor Index: This field indicates the number +of this Subsystem Namespace Descriptor in the +Subsystem Namespace Descriptor List. +.IP "flags" 12 +SSNS Flags, see \fIenum nbft_ssns_flags\fP. +.IP "trtype" 12 +Transport Type, see \fIenum nbft_trtype\fP. +.IP "trflags" 12 +Transport Specific Flags, see \fIenum nbft_ssns_trflags\fP. +.IP "primary_discovery_ctrl_index" 12 +Primary Discovery Controller Index: The Discovery +Descriptor Index field of the Discovery Descriptor +(see \fIstruct nbft_discovery\fP) that is associated with +this SSNS Descriptor. If a Discovery controller was +used to establish this record this value shall +be set to a non-zero value. If this namespace was +associated with multiple Discovery controllers, +those Discovery controllers shall have records +in the Discovery Descriptor to facilitate multi-path +rediscovery as required. If no Discovery controller +was utilized to inform this namespace record, +this field shall be cleared to 0h. +.IP "reserved1" 12 +Reserved. +.IP "subsys_traddr_obj" 12 +Subsystem Transport Address Heap Object Reference: +This field indicates the location and size of a heap +object containing the Subsystem Transport Address. +For IP based transports types, shall be an IP Address. +.IP "subsys_trsvcid_obj" 12 +Subsystem Transport Service Identifier Heap Object Reference: +This field indicates the location and size of a heap +object containing an array of bytes indicating +the Subsystem Transport Service Identifier. +See \fIenum nbft_trtype\fP. +.IP "subsys_port_id" 12 +Subsystem Port ID: Port in the NVM subsystem +associated with this transport address used by +the pre-OS driver. +.IP "nsid" 12 +Namespace ID: This field indicates the namespace +identifier (NSID) of the namespace indicated by +this descriptor. This field shall be cleared to 0h +if not specified by the user. If this value is cleared +to 0h, then consumers of the NBFT shall rely +on the NID. +.IP "nidt" 12 +Namespace Identifier Type (NIDT): This field +contains the value of the Namespace Identifier Type (NIDT) +field in the Namespace Identification Descriptor +for the namespace indicated by this descriptor. +If a namespace supports multiple NIDT entries +for uniqueness, the order of preference is NIDT field +value of 3h (i.e., UUID) before 2h (i.e., NSGUID), +and 2h before 1h (i.e., EUI-64). +.IP "nid" 12 +Namespace Identifier (NID): This field contains +the value of the Namespace Identifier (NID) field +in the Namespace Identification Descriptor for +the namespace indicated by this descriptor. +.IP "security_desc_index" 12 +Security Profile Descriptor Index: If the Use Security +Flag bit in the SSNS Flags field is set to 1h, then +this field indicates the value of the Security Profile +Descriptor Index field of the Security Profile +Descriptor (see \fIstruct nbft_security\fP) associated +with this namespace. If the Use Security Flag bit +is cleared to 0h, then no Security Profile Descriptor +is associated with this namespace and this field +is reserved. +.IP "primary_hfi_desc_index" 12 +Primary HFI Descriptor Index: This field indicates +the value of the HFI Descriptor Index field of the +HFI Descriptor (see \fIstruct nbft_hfi\fP) for the +interface associated with this namespace. If multiple +HFIs are associated with this record, subsequent +interfaces should be populated in the Secondary +HFI Associations field. +.IP "reserved2" 12 +Reserved. +.IP "secondary_hfi_assoc_obj" 12 +Secondary HFI Associations Heap Object Reference: +If this field is set to a non-zero value, then +this field indicates an array of bytes, in which +each byte contains the value of the HFI Descriptor +Index field of an HFI Descriptor in the HFI Descriptor +List. If this field is cleared to 0h, then no +secondary HFI associations are specified. +.IP "subsys_ns_nqn_obj" 12 +Subsystem and Namespace NQN Heap Object Reference: +This field indicates the location and size of +a heap object containing the Subsystem and Namespace NQN. +.IP "ssns_extended_info_desc_obj" 12 +SSNS Extended Information Descriptor Heap Object +Reference: If the SSNS Extended Info In-use Flag +bit is set to 1h, then this field indicates the +offset in bytes of a heap object containing an +SSNS Extended Information Descriptor +(see \fIstruct nbft_ssns_ext_info\fP) heap object +from byte offset 0h of the NBFT Table Header. +If the SSNS Extended Info In-use Flag bit is cleared +to 0h, then this field is reserved. +.IP "reserved3" 12 +Reserved. |