summaryrefslogtreecommitdiffstats
path: root/Documentation/hwmon/gl518sm.rst
diff options
context:
space:
mode:
authorDaniel Baumann <daniel.baumann@progress-linux.org>2024-04-11 08:27:49 +0000
committerDaniel Baumann <daniel.baumann@progress-linux.org>2024-04-11 08:27:49 +0000
commitace9429bb58fd418f0c81d4c2835699bddf6bde6 (patch)
treeb2d64bc10158fdd5497876388cd68142ca374ed3 /Documentation/hwmon/gl518sm.rst
parentInitial commit. (diff)
downloadlinux-ace9429bb58fd418f0c81d4c2835699bddf6bde6.tar.xz
linux-ace9429bb58fd418f0c81d4c2835699bddf6bde6.zip
Adding upstream version 6.6.15.upstream/6.6.15
Signed-off-by: Daniel Baumann <daniel.baumann@progress-linux.org>
Diffstat (limited to 'Documentation/hwmon/gl518sm.rst')
-rw-r--r--Documentation/hwmon/gl518sm.rst80
1 files changed, 80 insertions, 0 deletions
diff --git a/Documentation/hwmon/gl518sm.rst b/Documentation/hwmon/gl518sm.rst
new file mode 100644
index 0000000000..bf1e0b5e82
--- /dev/null
+++ b/Documentation/hwmon/gl518sm.rst
@@ -0,0 +1,80 @@
+Kernel driver gl518sm
+=====================
+
+Supported chips:
+
+ * Genesys Logic GL518SM release 0x00
+
+ Prefix: 'gl518sm'
+
+ Addresses scanned: I2C 0x2c and 0x2d
+
+ * Genesys Logic GL518SM release 0x80
+
+ Prefix: 'gl518sm'
+
+ Addresses scanned: I2C 0x2c and 0x2d
+
+ Datasheet: http://www.genesyslogic.com/
+
+Authors:
+ - Frodo Looijaard <frodol@dds.nl>,
+ - Kyösti Mälkki <kmalkki@cc.hut.fi>
+ - Hong-Gunn Chew <hglinux@gunnet.org>
+ - Jean Delvare <jdelvare@suse.de>
+
+Description
+-----------
+
+.. important::
+
+ For the revision 0x00 chip, the in0, in1, and in2 values (+5V, +3V,
+ and +12V) CANNOT be read. This is a limitation of the chip, not the driver.
+
+This driver supports the Genesys Logic GL518SM chip. There are at least
+two revision of this chip, which we call revision 0x00 and 0x80. Revision
+0x80 chips support the reading of all voltages and revision 0x00 only
+for VIN3.
+
+The GL518SM implements one temperature sensor, two fan rotation speed
+sensors, and four voltage sensors. It can report alarms through the
+computer speakers.
+
+Temperatures are measured in degrees Celsius. An alarm goes off while the
+temperature is above the over temperature limit, and has not yet dropped
+below the hysteresis limit. The alarm always reflects the current
+situation. Measurements are guaranteed between -10 degrees and +110
+degrees, with a accuracy of +/-3 degrees.
+
+Rotation speeds are reported in RPM (rotations per minute). An alarm is
+triggered if the rotation speed has dropped below a programmable limit. In
+case when you have selected to turn fan1 off, no fan1 alarm is triggered.
+
+Fan readings can be divided by a programmable divider (1, 2, 4 or 8) to
+give the readings more range or accuracy. Not all RPM values can
+accurately be represented, so some rounding is done. With a divider
+of 2, the lowest representable value is around 1900 RPM.
+
+Voltage sensors (also known as VIN sensors) report their values in volts.
+An alarm is triggered if the voltage has crossed a programmable minimum or
+maximum limit. Note that minimum in this case always means 'closest to
+zero'; this is important for negative voltage measurements. The VDD input
+measures voltages between 0.000 and 5.865 volt, with a resolution of 0.023
+volt. The other inputs measure voltages between 0.000 and 4.845 volt, with
+a resolution of 0.019 volt. Note that revision 0x00 chips do not support
+reading the current voltage of any input except for VIN3; limit setting and
+alarms work fine, though.
+
+When an alarm is triggered, you can be warned by a beeping signal through your
+computer speaker. It is possible to enable all beeping globally, or only the
+beeping for some alarms.
+
+If an alarm triggers, it will remain triggered until the hardware register
+is read at least once (except for temperature alarms). This means that the
+cause for the alarm may already have disappeared! Note that in the current
+implementation, all hardware registers are read whenever any data is read
+(unless it is less than 1.5 seconds since the last update). This means that
+you can easily miss once-only alarms.
+
+The GL518SM only updates its values each 1.5 seconds; reading it more often
+will do no harm, but will return 'old' values.