diff options
author | Daniel Baumann <daniel.baumann@progress-linux.org> | 2024-04-11 08:27:49 +0000 |
---|---|---|
committer | Daniel Baumann <daniel.baumann@progress-linux.org> | 2024-04-11 08:27:49 +0000 |
commit | ace9429bb58fd418f0c81d4c2835699bddf6bde6 (patch) | |
tree | b2d64bc10158fdd5497876388cd68142ca374ed3 /Documentation/hwmon/lineage-pem.rst | |
parent | Initial commit. (diff) | |
download | linux-ace9429bb58fd418f0c81d4c2835699bddf6bde6.tar.xz linux-ace9429bb58fd418f0c81d4c2835699bddf6bde6.zip |
Adding upstream version 6.6.15.upstream/6.6.15
Signed-off-by: Daniel Baumann <daniel.baumann@progress-linux.org>
Diffstat (limited to 'Documentation/hwmon/lineage-pem.rst')
-rw-r--r-- | Documentation/hwmon/lineage-pem.rst | 85 |
1 files changed, 85 insertions, 0 deletions
diff --git a/Documentation/hwmon/lineage-pem.rst b/Documentation/hwmon/lineage-pem.rst new file mode 100644 index 0000000000..10c271dc20 --- /dev/null +++ b/Documentation/hwmon/lineage-pem.rst @@ -0,0 +1,85 @@ +Kernel driver lineage-pem +========================= + +Supported devices: + + * Lineage Compact Power Line Power Entry Modules + + Prefix: 'lineage-pem' + + Addresses scanned: - + + Documentation: + + http://www.lineagepower.com/oem/pdf/CPLI2C.pdf + +Author: Guenter Roeck <linux@roeck-us.net> + + +Description +----------- + +This driver supports various Lineage Compact Power Line DC/DC and AC/DC +converters such as CP1800, CP2000AC, CP2000DC, CP2100DC, and others. + +Lineage CPL power entry modules are nominally PMBus compliant. However, most +standard PMBus commands are not supported. Specifically, all hardware monitoring +and status reporting commands are non-standard. For this reason, a standard +PMBus driver can not be used. + + +Usage Notes +----------- + +This driver does not probe for Lineage CPL devices, since there is no register +which can be safely used to identify the chip. You will have to instantiate +the devices explicitly. + +Example: the following will load the driver for a Lineage PEM at address 0x40 +on I2C bus #1:: + + $ modprobe lineage-pem + $ echo lineage-pem 0x40 > /sys/bus/i2c/devices/i2c-1/new_device + +All Lineage CPL power entry modules have a built-in I2C bus master selector +(PCA9541). To ensure device access, this driver should only be used as client +driver to the pca9541 I2C master selector driver. + + +Sysfs entries +------------- + +All Lineage CPL devices report output voltage and device temperature as well as +alarms for output voltage, temperature, input voltage, input current, input power, +and fan status. + +Input voltage, input current, input power, and fan speed measurement is only +supported on newer devices. The driver detects if those attributes are supported, +and only creates respective sysfs entries if they are. + +======================= =============================== +in1_input Output voltage (mV) +in1_min_alarm Output undervoltage alarm +in1_max_alarm Output overvoltage alarm +in1_crit Output voltage critical alarm + +in2_input Input voltage (mV, optional) +in2_alarm Input voltage alarm + +curr1_input Input current (mA, optional) +curr1_alarm Input overcurrent alarm + +power1_input Input power (uW, optional) +power1_alarm Input power alarm + +fan1_input Fan 1 speed (rpm, optional) +fan2_input Fan 2 speed (rpm, optional) +fan3_input Fan 3 speed (rpm, optional) + +temp1_input +temp1_max +temp1_crit +temp1_alarm +temp1_crit_alarm +temp1_fault +======================= =============================== |