summaryrefslogtreecommitdiffstats
path: root/tools/perf/pmu-events/arch/x86/meteorlake/pipeline.json
diff options
context:
space:
mode:
authorDaniel Baumann <daniel.baumann@progress-linux.org>2024-06-19 21:00:30 +0000
committerDaniel Baumann <daniel.baumann@progress-linux.org>2024-06-19 21:00:30 +0000
commite54def4ad8144ab15f826416e2e0f290ef1901b4 (patch)
tree583f8d4bd95cd67c44ff37b878a7eddfca9ab97a /tools/perf/pmu-events/arch/x86/meteorlake/pipeline.json
parentAdding upstream version 6.8.12. (diff)
downloadlinux-e54def4ad8144ab15f826416e2e0f290ef1901b4.tar.xz
linux-e54def4ad8144ab15f826416e2e0f290ef1901b4.zip
Adding upstream version 6.9.2.
Signed-off-by: Daniel Baumann <daniel.baumann@progress-linux.org>
Diffstat (limited to 'tools/perf/pmu-events/arch/x86/meteorlake/pipeline.json')
-rw-r--r--tools/perf/pmu-events/arch/x86/meteorlake/pipeline.json76
1 files changed, 76 insertions, 0 deletions
diff --git a/tools/perf/pmu-events/arch/x86/meteorlake/pipeline.json b/tools/perf/pmu-events/arch/x86/meteorlake/pipeline.json
index deaa7aba93..24bbfcebd2 100644
--- a/tools/perf/pmu-events/arch/x86/meteorlake/pipeline.json
+++ b/tools/perf/pmu-events/arch/x86/meteorlake/pipeline.json
@@ -1,5 +1,14 @@
[
{
+ "BriefDescription": "Counts the number of cycles when any of the dividers are active.",
+ "CounterMask": "1",
+ "EventCode": "0xcd",
+ "EventName": "ARITH.DIV_ACTIVE",
+ "SampleAfterValue": "1000003",
+ "UMask": "0x3",
+ "Unit": "cpu_atom"
+ },
+ {
"BriefDescription": "Cycles when divide unit is busy executing divide or square root operations.",
"CounterMask": "1",
"EventCode": "0xb0",
@@ -46,6 +55,15 @@
"Unit": "cpu_core"
},
{
+ "BriefDescription": "Counts the number of retired JCC (Jump on Conditional Code) branch instructions retired, includes both taken and not taken branches.",
+ "EventCode": "0xc4",
+ "EventName": "BR_INST_RETIRED.COND",
+ "PEBS": "1",
+ "SampleAfterValue": "200003",
+ "UMask": "0x7e",
+ "Unit": "cpu_atom"
+ },
+ {
"BriefDescription": "Conditional branch instructions retired.",
"EventCode": "0xc4",
"EventName": "BR_INST_RETIRED.COND",
@@ -66,6 +84,15 @@
"Unit": "cpu_core"
},
{
+ "BriefDescription": "Counts the number of taken JCC (Jump on Conditional Code) branch instructions retired.",
+ "EventCode": "0xc4",
+ "EventName": "BR_INST_RETIRED.COND_TAKEN",
+ "PEBS": "1",
+ "SampleAfterValue": "200003",
+ "UMask": "0xfe",
+ "Unit": "cpu_atom"
+ },
+ {
"BriefDescription": "Taken conditional branch instructions retired.",
"EventCode": "0xc4",
"EventName": "BR_INST_RETIRED.COND_TAKEN",
@@ -95,6 +122,15 @@
"Unit": "cpu_core"
},
{
+ "BriefDescription": "Counts the number of near indirect JMP and near indirect CALL branch instructions retired.",
+ "EventCode": "0xc4",
+ "EventName": "BR_INST_RETIRED.INDIRECT",
+ "PEBS": "1",
+ "SampleAfterValue": "200003",
+ "UMask": "0xeb",
+ "Unit": "cpu_atom"
+ },
+ {
"BriefDescription": "Indirect near branch instructions retired (excluding returns)",
"EventCode": "0xc4",
"EventName": "BR_INST_RETIRED.INDIRECT",
@@ -105,6 +141,25 @@
"Unit": "cpu_core"
},
{
+ "BriefDescription": "Counts the number of near indirect CALL branch instructions retired.",
+ "EventCode": "0xc4",
+ "EventName": "BR_INST_RETIRED.INDIRECT_CALL",
+ "PEBS": "1",
+ "SampleAfterValue": "200003",
+ "UMask": "0xfb",
+ "Unit": "cpu_atom"
+ },
+ {
+ "BriefDescription": "This event is deprecated. Refer to new event BR_INST_RETIRED.INDIRECT_CALL",
+ "Deprecated": "1",
+ "EventCode": "0xc4",
+ "EventName": "BR_INST_RETIRED.IND_CALL",
+ "PEBS": "1",
+ "SampleAfterValue": "200003",
+ "UMask": "0xfb",
+ "Unit": "cpu_atom"
+ },
+ {
"BriefDescription": "Counts the number of near CALL branch instructions retired.",
"EventCode": "0xc4",
"EventName": "BR_INST_RETIRED.NEAR_CALL",
@@ -124,6 +179,15 @@
"Unit": "cpu_core"
},
{
+ "BriefDescription": "Counts the number of near RET branch instructions retired.",
+ "EventCode": "0xc4",
+ "EventName": "BR_INST_RETIRED.NEAR_RETURN",
+ "PEBS": "1",
+ "SampleAfterValue": "200003",
+ "UMask": "0xf7",
+ "Unit": "cpu_atom"
+ },
+ {
"BriefDescription": "Return instructions retired.",
"EventCode": "0xc4",
"EventName": "BR_INST_RETIRED.NEAR_RETURN",
@@ -671,6 +735,7 @@
"BriefDescription": "INST_RETIRED.MACRO_FUSED",
"EventCode": "0xc0",
"EventName": "INST_RETIRED.MACRO_FUSED",
+ "PEBS": "1",
"SampleAfterValue": "2000003",
"UMask": "0x10",
"Unit": "cpu_core"
@@ -679,6 +744,7 @@
"BriefDescription": "Retired NOP instructions.",
"EventCode": "0xc0",
"EventName": "INST_RETIRED.NOP",
+ "PEBS": "1",
"PublicDescription": "Counts all retired NOP or ENDBR32/64 or PREFETCHIT0/1 instructions",
"SampleAfterValue": "2000003",
"UMask": "0x2",
@@ -697,6 +763,7 @@
"BriefDescription": "Iterations of Repeat string retired instructions.",
"EventCode": "0xc0",
"EventName": "INST_RETIRED.REP_ITERATION",
+ "PEBS": "1",
"PublicDescription": "Number of iterations of Repeat (REP) string retired instructions such as MOVS, CMPS, and SCAS. Each has a byte, word, and doubleword version and string instructions can be repeated using a repetition prefix, REP, that allows their architectural execution to be repeated a number of times as specified by the RCX register. Note the number of iterations is implementation-dependent.",
"SampleAfterValue": "2000003",
"UMask": "0x8",
@@ -980,6 +1047,15 @@
"Unit": "cpu_core"
},
{
+ "BriefDescription": "Counts the number of Last Branch Record (LBR) entries. Requires LBRs to be enabled and configured in IA32_LBR_CTL. [This event is alias to LBR_INSERTS.ANY]",
+ "EventCode": "0xe4",
+ "EventName": "MISC_RETIRED.LBR_INSERTS",
+ "PEBS": "1",
+ "SampleAfterValue": "1000003",
+ "UMask": "0x1",
+ "Unit": "cpu_atom"
+ },
+ {
"BriefDescription": "Counts cycles where the pipeline is stalled due to serializing operations.",
"EventCode": "0xa2",
"EventName": "RESOURCE_STALLS.SCOREBOARD",