summaryrefslogtreecommitdiffstats
path: root/Documentation/ABI/testing/sysfs-firmware-opal-sensor-groups
diff options
context:
space:
mode:
Diffstat (limited to '')
-rw-r--r--Documentation/ABI/testing/sysfs-firmware-opal-sensor-groups21
1 files changed, 21 insertions, 0 deletions
diff --git a/Documentation/ABI/testing/sysfs-firmware-opal-sensor-groups b/Documentation/ABI/testing/sysfs-firmware-opal-sensor-groups
new file mode 100644
index 0000000000..3a2dfe542e
--- /dev/null
+++ b/Documentation/ABI/testing/sysfs-firmware-opal-sensor-groups
@@ -0,0 +1,21 @@
+What: /sys/firmware/opal/sensor_groups
+Date: August 2017
+Contact: Linux for PowerPC mailing list <linuxppc-dev@ozlabs.org>
+Description: Sensor groups directory for POWER9 powernv servers
+
+ Each folder in this directory contains a sensor group
+ which are classified based on type of the sensor
+ like power, temperature, frequency, current, etc. They
+ can also indicate the group of sensors belonging to
+ different owners like CSM, Profiler, Job-Scheduler
+
+What: /sys/firmware/opal/sensor_groups/<sensor_group_name>/clear
+Date: August 2017
+Contact: Linux for PowerPC mailing list <linuxppc-dev@ozlabs.org>
+Description: Sysfs file to clear the min-max of all the sensors
+ belonging to the group.
+
+ Writing 1 to this file will clear the minimum and
+ maximum values of all the sensors in the group.
+ In POWER9, the min-max of a sensor is the historical minimum
+ and maximum value of the sensor cached by OCC.