+# SPDX-License-Identifier: GPL-2.0
+%YAML 1.2
+---
+$id: http://devicetree.org/schemas/regulator/regulator.yaml#
+$schema: http://devicetree.org/meta-schemas/core.yaml#
+
+title: Voltage/Current Regulators
+
+maintainers:
+ - Liam Girdwood <lgirdwood@gmail.com>
+ - Mark Brown <broonie@kernel.org>
+
+properties:
+ regulator-name:
+ description: A string used as a descriptive name for regulator outputs
+ $ref: /schemas/types.yaml#/definitions/string
+
+ regulator-min-microvolt:
+ description: smallest voltage consumers may set
+
+ regulator-max-microvolt:
+ description: largest voltage consumers may set
+
+ regulator-microvolt-offset:
+ description: Offset applied to voltages to compensate for voltage drops
+ $ref: /schemas/types.yaml#/definitions/uint32
+
+ regulator-min-microamp:
+ description: smallest current consumers may set
+
+ regulator-max-microamp:
+ description: largest current consumers may set
+
+ regulator-input-current-limit-microamp:
+ description: maximum input current regulator allows
+
+ regulator-always-on:
+ description: boolean, regulator should never be disabled
+ type: boolean
+
+ regulator-boot-on:
+ description: bootloader/firmware enabled regulator.
+ It's expected that this regulator was left on by the bootloader.
+ If the bootloader didn't leave it on then OS should turn it on
+ at boot but shouldn't prevent it from being turned off later.
+ This property is intended to only be used for regulators where
+ software cannot read the state of the regulator.
+ type: boolean
+
+ regulator-allow-bypass:
+ description: allow the regulator to go into bypass mode
+ type: boolean
+
+ regulator-allow-set-load:
+ description: allow the regulator performance level to be configured
+ type: boolean
+
+ regulator-ramp-delay:
+ description: ramp delay for regulator(in uV/us) For hardware which supports
+ disabling ramp rate, it should be explicitly initialised to zero (regulator-ramp-delay
+ = <0>) for disabling ramp delay.
+ $ref: /schemas/types.yaml#/definitions/uint32
+
+ regulator-enable-ramp-delay:
+ description: The time taken, in microseconds, for the supply rail to
+ reach the target voltage, plus/minus whatever tolerance the board
+ design requires. This property describes the total system ramp time
+ required due to the combination of internal ramping of the regulator
+ itself, and board design issues such as trace capacitance and load
+ on the supply.
+ $ref: /schemas/types.yaml#/definitions/uint32
+
+ regulator-settling-time-us:
+ description: Settling time, in microseconds, for voltage change if regulator
+ have the constant time for any level voltage change. This is useful
+ when regulator have exponential voltage change.
+
+ regulator-settling-time-up-us:
+ description: Settling time, in microseconds, for voltage increase if
+ the regulator needs a constant time to settle after voltage increases
+ of any level. This is useful for regulators with exponential voltage
+ changes.
+
+ regulator-settling-time-down-us:
+ description: Settling time, in microseconds, for voltage decrease if
+ the regulator needs a constant time to settle after voltage decreases
+ of any level. This is useful for regulators with exponential voltage
+ changes.
+
+ regulator-soft-start:
+ description: Enable soft start so that voltage ramps slowly
+ type: boolean
+
+ regulator-initial-mode:
+ description: initial operating mode. The set of possible operating modes
+ depends on the capabilities of every hardware so each device binding
+ documentation explains which values the regulator supports.
+ $ref: /schemas/types.yaml#/definitions/uint32
+
+ regulator-allowed-modes:
+ description: list of operating modes that software is allowed to configure
+ for the regulator at run-time. Elements may be specified in any order.
+ The set of possible operating modes depends on the capabilities of
+ every hardware so each device binding document explains which values
+ the regulator supports.
+ $ref: /schemas/types.yaml#/definitions/uint32-array
+
+ regulator-system-load:
+ description: Load in uA present on regulator that is not captured by
+ any consumer request.
+ $ref: /schemas/types.yaml#/definitions/uint32
+
+ regulator-pull-down:
+ description: Enable pull down resistor when the regulator is disabled.
+ type: boolean
+
+ regulator-over-current-protection:
+ description: Enable over current protection.
+ type: boolean
+
+ regulator-oc-protection-microamp:
+ description: Set over current protection limit. This is a limit where
+ hardware performs emergency shutdown. Zero can be passed to disable
+ protection and value '1' indicates that protection should be enabled but
+ limit setting can be omitted.
+
+ regulator-oc-error-microamp:
+ description: Set over current error limit. This is a limit where part of
+ the hardware probably is malfunctional and damage prevention is requested.
+ Zero can be passed to disable error detection and value '1' indicates
+ that detection should be enabled but limit setting can be omitted.
+
+ regulator-oc-warn-microamp:
+ description: Set over current warning limit. This is a limit where hardware
+ is assumed still to be functional but approaching limit where it gets
+ damaged. Recovery actions should be initiated. Zero can be passed to
+ disable detection and value '1' indicates that detection should
+ be enabled but limit setting can be omitted.
+
+ regulator-ov-protection-microvolt:
+ description: Set over voltage protection limit. This is a limit where
+ hardware performs emergency shutdown. Zero can be passed to disable
+ protection and value '1' indicates that protection should be enabled but
+ limit setting can be omitted. Limit is given as microvolt offset from
+ voltage set to regulator.
+
+ regulator-ov-error-microvolt:
+ description: Set over voltage error limit. This is a limit where part of
+ the hardware probably is malfunctional and damage prevention is requested
+ Zero can be passed to disable error detection and value '1' indicates
+ that detection should be enabled but limit setting can be omitted. Limit
+ is given as microvolt offset from voltage set to regulator.
+
+ regulator-ov-warn-microvolt:
+ description: Set over voltage warning limit. This is a limit where hardware
+ is assumed still to be functional but approaching limit where it gets
+ damaged. Recovery actions should be initiated. Zero can be passed to
+ disable detection and value '1' indicates that detection should
+ be enabled but limit setting can be omitted. Limit is given as microvolt
+ offset from voltage set to regulator.
+
+ regulator-uv-protection-microvolt:
+ description: Set over under voltage protection limit. This is a limit where
+ hardware performs emergency shutdown. Zero can be passed to disable
+ protection and value '1' indicates that protection should be enabled but
+ limit setting can be omitted. Limit is given as microvolt offset from
+ voltage set to regulator.
+
+ regulator-uv-error-microvolt:
+ description: Set under voltage error limit. This is a limit where part of
+ the hardware probably is malfunctional and damage prevention is requested
+ Zero can be passed to disable error detection and value '1' indicates
+ that detection should be enabled but limit setting can be omitted. Limit
+ is given as microvolt offset from voltage set to regulator.
+
+ regulator-uv-warn-microvolt:
+ description: Set over under voltage warning limit. This is a limit where
+ hardware is assumed still to be functional but approaching limit where
+ it gets damaged. Recovery actions should be initiated. Zero can be passed
+ to disable detection and value '1' indicates that detection should
+ be enabled but limit setting can be omitted. Limit is given as microvolt
+ offset from voltage set to regulator.
+
+ regulator-temp-protection-kelvin:
+ description: Set over temperature protection limit. This is a limit where
+ hardware performs emergency shutdown. Zero can be passed to disable
+ protection and value '1' indicates that protection should be enabled but
+ limit setting can be omitted.
+
+ regulator-temp-error-kelvin:
+ description: Set over temperature error limit. This is a limit where part of
+ the hardware probably is malfunctional and damage prevention is requested
+ Zero can be passed to disable error detection and value '1' indicates
+ that detection should be enabled but limit setting can be omitted.
+
+ regulator-temp-warn-kelvin:
+ description: Set over temperature warning limit. This is a limit where
+ hardware is assumed still to be functional but approaching limit where it
+ gets damaged. Recovery actions should be initiated. Zero can be passed to
+ disable detection and value '1' indicates that detection should
+ be enabled but limit setting can be omitted.
+
+ regulator-active-discharge:
+ description: |
+ tristate, enable/disable active discharge of regulators. The values are:
+ 0: Disable active discharge.
+ 1: Enable active discharge.
+ Absence of this property will leave configuration to default.
+ $ref: /schemas/types.yaml#/definitions/uint32
+ enum: [0, 1]
+
+ regulator-coupled-with:
+ description: Regulators with which the regulator is coupled. The linkage
+ is 2-way - all coupled regulators should be linked with each other.
+ A regulator should not be coupled with its supplier.
+ $ref: /schemas/types.yaml#/definitions/phandle-array
+ items:
+ maxItems: 1
+
+ regulator-coupled-max-spread:
+ description: Array of maximum spread between voltages of coupled regulators
+ in microvolts, each value in the array relates to the corresponding
+ couple specified by the regulator-coupled-with property.
+ $ref: /schemas/types.yaml#/definitions/uint32-array
+
+ regulator-max-step-microvolt:
+ description: Maximum difference between current and target voltages
+ that can be changed safely in a single step.
+
+patternProperties:
+ ".*-supply$":
+ description: Input supply phandle(s) for this node
+
+ "^regulator-state-(standby|mem|disk)$":
+ type: object
+ description:
+ sub-nodes for regulator state in Standby, Suspend-to-RAM, and
+ Suspend-to-DISK modes. Equivalent with standby, mem, and disk Linux
+ sleep states.
+
+ properties:
+ regulator-on-in-suspend:
+ description: regulator should be on in suspend state.
+ type: boolean
+
+ regulator-off-in-suspend:
+ description: regulator should be off in suspend state.
+ type: boolean
+
+ regulator-suspend-min-microvolt:
+ description: minimum voltage may be set in suspend state.
+
+ regulator-suspend-max-microvolt:
+ description: maximum voltage may be set in suspend state.
+
+ regulator-suspend-microvolt:
+ description: the default voltage which regulator would be set in
+ suspend. This property is now deprecated, instead setting voltage
+ for suspend mode via the API which regulator driver provides is
+ recommended.
+
+ regulator-changeable-in-suspend:
+ description: whether the default voltage and the regulator on/off
+ in suspend can be changed in runtime.
+ type: boolean
+
+ regulator-mode:
+ description: operating mode in the given suspend state. The set
+ of possible operating modes depends on the capabilities of every
+ hardware so the valid modes are documented on each regulator device
+ tree binding document.
+ $ref: /schemas/types.yaml#/definitions/uint32
+
+ additionalProperties: false
+
+additionalProperties: true
+
+examples:
+ - |
+ xyzreg: regulator {
+ regulator-min-microvolt = <1000000>;
+ regulator-max-microvolt = <2500000>;
+ regulator-always-on;
+ vin-supply = <&vin>;
+
+ regulator-state-mem {
+ regulator-on-in-suspend;
+ };
+ };
+
+...