diff options
Diffstat (limited to 'kernel/sched/fair.c')
-rw-r--r-- | kernel/sched/fair.c | 53 |
1 files changed, 34 insertions, 19 deletions
diff --git a/kernel/sched/fair.c b/kernel/sched/fair.c index aee5e7a701..a01269ed96 100644 --- a/kernel/sched/fair.c +++ b/kernel/sched/fair.c @@ -6669,22 +6669,42 @@ static inline void hrtick_update(struct rq *rq) #ifdef CONFIG_SMP static inline bool cpu_overutilized(int cpu) { - unsigned long rq_util_min = uclamp_rq_get(cpu_rq(cpu), UCLAMP_MIN); - unsigned long rq_util_max = uclamp_rq_get(cpu_rq(cpu), UCLAMP_MAX); + unsigned long rq_util_min, rq_util_max; + + if (!sched_energy_enabled()) + return false; + + rq_util_min = uclamp_rq_get(cpu_rq(cpu), UCLAMP_MIN); + rq_util_max = uclamp_rq_get(cpu_rq(cpu), UCLAMP_MAX); /* Return true only if the utilization doesn't fit CPU's capacity */ return !util_fits_cpu(cpu_util_cfs(cpu), rq_util_min, rq_util_max, cpu); } -static inline void update_overutilized_status(struct rq *rq) +static inline void set_rd_overutilized_status(struct root_domain *rd, + unsigned int status) { - if (!READ_ONCE(rq->rd->overutilized) && cpu_overutilized(rq->cpu)) { - WRITE_ONCE(rq->rd->overutilized, SG_OVERUTILIZED); - trace_sched_overutilized_tp(rq->rd, SG_OVERUTILIZED); - } + if (!sched_energy_enabled()) + return; + + WRITE_ONCE(rd->overutilized, status); + trace_sched_overutilized_tp(rd, !!status); +} + +static inline void check_update_overutilized_status(struct rq *rq) +{ + /* + * overutilized field is used for load balancing decisions only + * if energy aware scheduler is being used + */ + if (!sched_energy_enabled()) + return; + + if (!READ_ONCE(rq->rd->overutilized) && cpu_overutilized(rq->cpu)) + set_rd_overutilized_status(rq->rd, SG_OVERUTILIZED); } #else -static inline void update_overutilized_status(struct rq *rq) { } +static inline void check_update_overutilized_status(struct rq *rq) { } #endif /* Runqueue only has SCHED_IDLE tasks enqueued */ @@ -6785,7 +6805,7 @@ enqueue_task_fair(struct rq *rq, struct task_struct *p, int flags) * and the following generally works well enough in practice. */ if (!task_new) - update_overutilized_status(rq); + check_update_overutilized_status(rq); enqueue_throttle: assert_list_leaf_cfs_rq(rq); @@ -10621,19 +10641,14 @@ next_group: env->fbq_type = fbq_classify_group(&sds->busiest_stat); if (!env->sd->parent) { - struct root_domain *rd = env->dst_rq->rd; - /* update overload indicator if we are at root domain */ - WRITE_ONCE(rd->overload, sg_status & SG_OVERLOAD); + WRITE_ONCE(env->dst_rq->rd->overload, sg_status & SG_OVERLOAD); /* Update over-utilization (tipping point, U >= 0) indicator */ - WRITE_ONCE(rd->overutilized, sg_status & SG_OVERUTILIZED); - trace_sched_overutilized_tp(rd, sg_status & SG_OVERUTILIZED); + set_rd_overutilized_status(env->dst_rq->rd, + sg_status & SG_OVERUTILIZED); } else if (sg_status & SG_OVERUTILIZED) { - struct root_domain *rd = env->dst_rq->rd; - - WRITE_ONCE(rd->overutilized, SG_OVERUTILIZED); - trace_sched_overutilized_tp(rd, SG_OVERUTILIZED); + set_rd_overutilized_status(env->dst_rq->rd, SG_OVERUTILIZED); } update_idle_cpu_scan(env, sum_util); @@ -12639,7 +12654,7 @@ static void task_tick_fair(struct rq *rq, struct task_struct *curr, int queued) task_tick_numa(rq, curr); update_misfit_status(curr, rq); - update_overutilized_status(task_rq(curr)); + check_update_overutilized_status(task_rq(curr)); task_tick_core(rq, curr); } |