From e54def4ad8144ab15f826416e2e0f290ef1901b4 Mon Sep 17 00:00:00 2001 From: Daniel Baumann Date: Wed, 19 Jun 2024 23:00:30 +0200 Subject: Adding upstream version 6.9.2. Signed-off-by: Daniel Baumann --- Documentation/hwmon/chipcap2.rst | 73 ++++++++++++++++++++++++++++++++++++++++ 1 file changed, 73 insertions(+) create mode 100644 Documentation/hwmon/chipcap2.rst (limited to 'Documentation/hwmon/chipcap2.rst') diff --git a/Documentation/hwmon/chipcap2.rst b/Documentation/hwmon/chipcap2.rst new file mode 100644 index 000000000..dc165becc --- /dev/null +++ b/Documentation/hwmon/chipcap2.rst @@ -0,0 +1,73 @@ +.. SPDX-License-Identifier: GPL-2.0-or-later + +Kernel driver ChipCap2 +====================== + +Supported chips: + + * Amphenol CC2D23, CC2D23S, CC2D25, CC2D25S, CC2D33, CC2D33S, CC2D35, CC2D35S + + Prefix: 'chipcap2' + + Addresses scanned: - + + Datasheet: https://www.amphenol-sensors.com/en/telaire/humidity/527-humidity-sensors/3095-chipcap-2 + +Author: + + - Javier Carrasco + +Description +----------- + +This driver implements support for the Amphenol ChipCap 2, a humidity and +temperature chip family. Temperature is measured in milli degrees celsius, +relative humidity is expressed as a per cent mille. The measurement ranges +are the following: + + - Relative humidity: 0 to 100000 pcm (14-bit resolution) + - Temperature: -40000 to +125000 m°C (14-bit resolution) + +The device communicates with the I2C protocol and uses the I2C address 0x28 +by default. + +Depending on the hardware configuration, up to two humidity alarms to control +minimum and maximum values are provided. Their thresholds and hystersis can be +configured via sysfs. + +Thresholds and hysteris must be provided as a per cent mille. These values +might be truncated to match the 14-bit device resolution (6.1 pcm/LSB) + +Known Issues +------------ + +The driver does not support I2C address and command window length modification. + +sysfs-Interface +--------------- + +The following list includes the sysfs attributes that the driver always provides, +their permissions and a short description: + +=============================== ======= ======================================== +Name Perm Description +=============================== ======= ======================================== +temp1_input: RO temperature input +humidity1_input: RO humidity input +=============================== ======= ======================================== + +The following list includes the sysfs attributes that the driver may provide +depending on the hardware configuration: + +=============================== ======= ======================================== +Name Perm Description +=============================== ======= ======================================== +humidity1_min: RW humidity low limit. Measurements under + this limit trigger a humidity low alarm +humidity1_max: RW humidity high limit. Measurements above + this limit trigger a humidity high alarm +humidity1_min_hyst: RW humidity low hystersis +humidity1_max_hyst: RW humidity high hystersis +humidity1_min_alarm: RO humidity low alarm indicator +humidity1_max_alarm: RO humidity high alarm indicator +=============================== ======= ======================================== -- cgit v1.2.3