From ace9429bb58fd418f0c81d4c2835699bddf6bde6 Mon Sep 17 00:00:00 2001 From: Daniel Baumann Date: Thu, 11 Apr 2024 10:27:49 +0200 Subject: Adding upstream version 6.6.15. Signed-off-by: Daniel Baumann --- Documentation/hwmon/pli1209bc.rst | 75 +++++++++++++++++++++++++++++++++++++++ 1 file changed, 75 insertions(+) create mode 100644 Documentation/hwmon/pli1209bc.rst (limited to 'Documentation/hwmon/pli1209bc.rst') diff --git a/Documentation/hwmon/pli1209bc.rst b/Documentation/hwmon/pli1209bc.rst new file mode 100644 index 0000000000..ea5b3f68a5 --- /dev/null +++ b/Documentation/hwmon/pli1209bc.rst @@ -0,0 +1,75 @@ +.. SPDX-License-Identifier: GPL-2.0 + +Kernel driver pli1209bc +======================= + +Supported chips: + + * Digital Supervisor PLI1209BC + + Prefix: 'pli1209bc' + + Addresses scanned: 0x50 - 0x5F + + Datasheet: https://www.vicorpower.com/documents/datasheets/ds-PLI1209BCxyzz-VICOR.pdf + +Authors: + - Marcello Sylvester Bauer + +Description +----------- + +The Vicor PLI1209BC is an isolated digital power system supervisor that provides +a communication interface between a host processor and one Bus Converter Module +(BCM). The PLI communicates with a system controller via a PMBus compatible +interface over an isolated UART interface. Through the PLI, the host processor +can configure, set protection limits, and monitor the BCM. + +Sysfs entries +------------- + +======================= ======================================================== +in1_label "vin2" +in1_input Input voltage. +in1_rated_min Minimum rated input voltage. +in1_rated_max Maximum rated input voltage. +in1_max Maximum input voltage. +in1_max_alarm Input voltage high alarm. +in1_crit Critical input voltage. +in1_crit_alarm Input voltage critical alarm. + +in2_label "vout2" +in2_input Output voltage. +in2_rated_min Minimum rated output voltage. +in2_rated_max Maximum rated output voltage. +in2_alarm Output voltage alarm + +curr1_label "iin2" +curr1_input Input current. +curr1_max Maximum input current. +curr1_max_alarm Maximum input current high alarm. +curr1_crit Critical input current. +curr1_crit_alarm Input current critical alarm. + +curr2_label "iout2" +curr2_input Output current. +curr2_crit Critical output current. +curr2_crit_alarm Output current critical alarm. +curr2_max Maximum output current. +curr2_max_alarm Output current high alarm. + +power1_label "pin2" +power1_input Input power. +power1_alarm Input power alarm. + +power2_label "pout2" +power2_input Output power. +power2_rated_max Maximum rated output power. + +temp1_input Die temperature. +temp1_alarm Die temperature alarm. +temp1_max Maximum die temperature. +temp1_max_alarm Die temperature high alarm. +temp1_crit Critical die temperature. +temp1_crit_alarm Die temperature critical alarm. +======================= ======================================================== -- cgit v1.2.3