summaryrefslogtreecommitdiffstats
path: root/upstream/archlinux/man8/sm-notify.8
diff options
context:
space:
mode:
authorDaniel Baumann <daniel.baumann@progress-linux.org>2024-04-15 19:43:11 +0000
committerDaniel Baumann <daniel.baumann@progress-linux.org>2024-04-15 19:43:11 +0000
commitfc22b3d6507c6745911b9dfcc68f1e665ae13dbc (patch)
treece1e3bce06471410239a6f41282e328770aa404a /upstream/archlinux/man8/sm-notify.8
parentInitial commit. (diff)
downloadmanpages-l10n-fc22b3d6507c6745911b9dfcc68f1e665ae13dbc.tar.xz
manpages-l10n-fc22b3d6507c6745911b9dfcc68f1e665ae13dbc.zip
Adding upstream version 4.22.0.upstream/4.22.0
Signed-off-by: Daniel Baumann <daniel.baumann@progress-linux.org>
Diffstat (limited to 'upstream/archlinux/man8/sm-notify.8')
-rw-r--r--upstream/archlinux/man8/sm-notify.8366
1 files changed, 366 insertions, 0 deletions
diff --git a/upstream/archlinux/man8/sm-notify.8 b/upstream/archlinux/man8/sm-notify.8
new file mode 100644
index 00000000..addf5d3c
--- /dev/null
+++ b/upstream/archlinux/man8/sm-notify.8
@@ -0,0 +1,366 @@
+.\"@(#)sm-notify.8"
+.\"
+.\" Copyright (C) 2004 Olaf Kirch <okir@suse.de>
+.\"
+.\" Rewritten by Chuck Lever <chuck.lever@oracle.com>, 2009.
+.\" Copyright 2009 Oracle. All rights reserved.
+.\"
+.TH SM-NOTIFY 8 "1 November 2009
+.SH NAME
+sm-notify \- send reboot notifications to NFS peers
+.SH SYNOPSIS
+.BI "/usr/sbin/sm-notify [-dfn] [-m " minutes "] [-v " name "] [-p " notify-port "] [-P " path "]
+.SH DESCRIPTION
+File locks are not part of persistent file system state.
+Lock state is thus lost when a host reboots.
+.PP
+Network file systems must also detect when lock state is lost
+because a remote host has rebooted.
+After an NFS client reboots, an NFS server must release all file locks
+held by applications that were running on that client.
+After a server reboots, a client must remind the
+server of file locks held by applications running on that client.
+.PP
+For NFS version 2 and version 3, the
+.I Network Status Monitor
+protocol (or NSM for short)
+is used to notify NFS peers of reboots.
+On Linux, two separate user-space components constitute the NSM service:
+.TP
+.B sm-notify
+A helper program that notifies NFS peers after the local system reboots
+.TP
+.B rpc.statd
+A daemon that listens for reboot notifications from other hosts, and
+manages the list of hosts to be notified when the local system reboots
+.PP
+The local NFS lock manager alerts its local
+.B rpc.statd
+of each remote peer that should be monitored.
+When the local system reboots, the
+.B sm-notify
+command notifies the NSM service on monitored peers of the reboot.
+When a remote reboots, that peer notifies the local
+.BR rpc.statd ,
+which in turn passes the reboot notification
+back to the local NFS lock manager.
+.SH NSM OPERATION IN DETAIL
+The first file locking interaction between an NFS client and server causes
+the NFS lock managers on both peers to contact their local NSM service to
+store information about the opposite peer.
+On Linux, the local lock manager contacts
+.BR rpc.statd .
+.PP
+.B rpc.statd
+records information about each monitored NFS peer on persistent storage.
+This information describes how to contact a remote peer
+in case the local system reboots,
+how to recognize which monitored peer is reporting a reboot,
+and how to notify the local lock manager when a monitored peer
+indicates it has rebooted.
+.PP
+An NFS client sends a hostname, known as the client's
+.IR caller_name ,
+in each file lock request.
+An NFS server can use this hostname to send asynchronous GRANT
+calls to a client, or to notify the client it has rebooted.
+.PP
+The Linux NFS server can provide the client's
+.I caller_name
+or the client's network address to
+.BR rpc.statd .
+For the purposes of the NSM protocol,
+this name or address is known as the monitored peer's
+.IR mon_name .
+In addition, the local lock manager tells
+.B rpc.statd
+what it thinks its own hostname is.
+For the purposes of the NSM protocol,
+this hostname is known as
+.IR my_name .
+.PP
+There is no equivalent interaction between an NFS server and a client
+to inform the client of the server's
+.IR caller_name .
+Therefore NFS clients do not actually know what
+.I mon_name
+an NFS server might use in an SM_NOTIFY request.
+The Linux NFS client records the server's hostname used on the mount command
+to identify rebooting NFS servers.
+.SS Reboot notification
+When the local system reboots, the
+.B sm-notify
+command reads the list of monitored peers from persistent storage and
+sends an SM_NOTIFY request to the NSM service on each listed remote peer.
+It uses the
+.I mon_name
+string as the destination.
+To identify which host has rebooted, the
+.B sm-notify
+command normally sends
+.I my_name
+string recorded when that remote was monitored.
+The remote
+.B rpc.statd
+matches incoming SM_NOTIFY requests using this string,
+or the caller's network address,
+to one or more peers on its own monitor list.
+.PP
+If
+.B rpc.statd
+does not find a peer on its monitor list that matches
+an incoming SM_NOTIFY request,
+the notification is not forwarded to the local lock manager.
+In addition, each peer has its own
+.IR "NSM state number" ,
+a 32-bit integer that is bumped after each reboot by the
+.B sm-notify
+command.
+.B rpc.statd
+uses this number to distinguish between actual reboots
+and replayed notifications.
+.PP
+Part of NFS lock recovery is rediscovering
+which peers need to be monitored again.
+The
+.B sm-notify
+command clears the monitor list on persistent storage after each reboot.
+.SH OPTIONS
+.TP
+.B -d
+Keeps
+.B sm-notify
+attached to its controlling terminal and running in the foreground
+so that notification progress may be monitored directly.
+.TP
+.B -f
+Send notifications even if
+.B sm-notify
+has already run since the last system reboot.
+.TP
+.BI -m " retry-time
+Specifies the length of time, in minutes, to continue retrying
+notifications to unresponsive hosts.
+If this option is not specified,
+.B sm-notify
+attempts to send notifications for 15 minutes.
+Specifying a value of 0 causes
+.B sm-notify
+to continue sending notifications to unresponsive peers
+until it is manually killed.
+.IP
+Notifications are retried if sending fails,
+the remote does not respond,
+the remote's NSM service is not registered,
+or if there is a DNS failure
+which prevents the remote's
+.I mon_name
+from being resolved to an address.
+.IP
+Hosts are not removed from the notification list until a valid
+reply has been received.
+However, the SM_NOTIFY procedure has a void result.
+There is no way for
+.B sm-notify
+to tell if the remote recognized the sender and has started
+appropriate lock recovery.
+.TP
+.B -n
+Prevents
+.B sm-notify
+from updating the local system's NSM state number.
+.TP
+.BI -p " port
+Specifies the source port number
+.B sm-notify
+should use when sending reboot notifications.
+If this option is not specified, a randomly chosen ephemeral port is used.
+.IP
+This option can be used to traverse a firewall between client and server.
+.TP
+.BI "\-P, " "" \-\-state\-directory\-path " pathname
+Specifies the pathname of the parent directory
+where NSM state information resides.
+If this option is not specified,
+.B sm-notify
+uses
+.I /var/lib/nfs
+by default.
+.IP
+After starting,
+.B sm-notify
+attempts to set its effective UID and GID to the owner
+and group of the subdirectory
+.B sm
+of this directory. After changing the effective ids,
+.B sm-notify
+only needs to access files in
+.B sm
+and
+.B sm.bak
+within the state-directory-path.
+.TP
+.BI -v " ipaddr " | " hostname
+Specifies the network address from which to send reboot notifications,
+and the
+.I mon_name
+argument to use when sending SM_NOTIFY requests.
+If this option is not specified,
+.B sm-notify
+uses a wildcard address as the transport bind address,
+and uses the
+.I my_name
+recorded when the remote was monitored as the
+.I mon_name
+argument when sending SM_NOTIFY requests.
+.IP
+The
+.I ipaddr
+form can be expressed as either an IPv4 or an IPv6 presentation address.
+If the
+.I ipaddr
+form is used, the
+.B sm-notify
+command converts this address to a hostname for use as the
+.I mon_name
+argument when sending SM_NOTIFY requests.
+.IP
+This option can be useful in multi-homed configurations where
+the remote requires notification from a specific network address.
+.SH CONFIGURATION FILE
+Many of the options that can be set on the command line can also be
+controlled through values set in the
+.B [sm-notify]
+or, in one case, the
+.B [statd]
+section of the
+.I /etc/nfs.conf
+configuration file.
+
+Values recognized in the
+.B [sm-notify]
+section include:
+.BR retry-time ,
+.BR outgoing-port ", and"
+.BR outgoing-addr .
+These have the same effect as the command line options
+.BR m ,
+.BR p ", and"
+.B v
+respectively.
+
+An additional value recognized in the
+.B [sm-notify]
+section is
+.BR lift-grace .
+By default,
+.B sm-notify
+will lift lockd's grace period early if it has no hosts to notify.
+Some high availability configurations will run one
+.B sm-notify
+per floating IP address. In these configurations, lifting the
+grace period early may prevent clients from reclaiming locks.
+.RB "Setting " lift-grace " to " n
+will prevent
+.B sm-notify
+from ending the grace period early.
+.B lift-grace
+has no corresponding command line option.
+
+The value recognized in the
+.B [statd]
+section is
+.BR state-directory-path .
+
+.SH SECURITY
+The
+.B sm-notify
+command must be started as root to acquire privileges needed
+to access the state information database.
+It drops root privileges
+as soon as it starts up to reduce the risk of a privilege escalation attack.
+.PP
+During normal operation,
+the effective user ID it chooses is the owner of the state directory.
+This allows it to continue to access files in that directory after it
+has dropped its root privileges.
+To control which user ID
+.B rpc.statd
+chooses, simply use
+.BR chown (1)
+to set the owner of
+the state directory.
+.SH ADDITIONAL NOTES
+Lock recovery after a reboot is critical to maintaining data integrity
+and preventing unnecessary application hangs.
+.PP
+To help
+.B rpc.statd
+match SM_NOTIFY requests to NLM requests, a number of best practices
+should be observed, including:
+.IP
+The UTS nodename of your systems should match the DNS names that NFS
+peers use to contact them
+.IP
+The UTS nodenames of your systems should always be fully qualified domain names
+.IP
+The forward and reverse DNS mapping of the UTS nodenames should be
+consistent
+.IP
+The hostname the client uses to mount the server should match the server's
+.I mon_name
+in SM_NOTIFY requests it sends
+.PP
+Unmounting an NFS file system does not necessarily stop
+either the NFS client or server from monitoring each other.
+Both may continue monitoring each other for a time in case subsequent
+NFS traffic between the two results in fresh mounts and additional
+file locking.
+.PP
+On Linux, if the
+.B lockd
+kernel module is unloaded during normal operation,
+all remote NFS peers are unmonitored.
+This can happen on an NFS client, for example,
+if an automounter removes all NFS mount
+points due to inactivity.
+.SS IPv6 and TI-RPC support
+TI-RPC is a pre-requisite for supporting NFS on IPv6.
+If TI-RPC support is built into the
+.B sm-notify
+command ,it will choose an appropriate IPv4 or IPv6 transport
+based on the network address returned by DNS for each remote peer.
+It should be fully compatible with remote systems
+that do not support TI-RPC or IPv6.
+.PP
+Currently, the
+.B sm-notify
+command supports sending notification only via datagram transport protocols.
+.SH FILES
+.TP 2.5i
+.I /var/lib/nfs/sm
+directory containing monitor list
+.TP 2.5i
+.I /var/lib/nfs/sm.bak
+directory containing notify list
+.TP 2.5i
+.I /var/lib/nfs/state
+NSM state number for this host
+.TP 2.5i
+.I /proc/sys/fs/nfs/nsm_local_state
+kernel's copy of the NSM state number
+.SH SEE ALSO
+.BR rpc.statd (8),
+.BR nfs (5),
+.BR uname (2),
+.BR hostname (7)
+.PP
+RFC 1094 - "NFS: Network File System Protocol Specification"
+.br
+RFC 1813 - "NFS Version 3 Protocol Specification"
+.br
+OpenGroup Protocols for Interworking: XNFS, Version 3W - Chapter 11
+.SH AUTHORS
+Olaf Kirch <okir@suse.de>
+.br
+Chuck Lever <chuck.lever@oracle.com>